Copied share/* from the CVS head to this branch.
Updated src/lib/dict.c && src/lib/radius.c to handle (encode and
decode) VSA's with weird formats, with code copied from the CVS
head.
Updated "configure.in" to look for sys/stat.h, which is now needed
by src/lib/dict.c.
Updated "configure.in" with the new version number (1.1.0-pre0),
but did NOT re-run "configure"
dnl # The version of the software
RADIUSD_MAJOR_VERSION=1
-RADIUSD_MINOR_VERSION=0.2
+RADIUSD_MINOR_VERSION=1.0-pre0
RADIUSD_VERSION="${RADIUSD_MAJOR_VERSION}.${RADIUSD_MINOR_VERSION}"
dnl #############################################################
*-interix*)
CFLAGS="$CFLAGS -D_ALL_SOURCE"
;;
+*-darwin*)
+ CFLAGS="$CFLAGS -DDARWIN"
+ ;;
esac
AC_HEADER_DIRENT
sys/security.h \
fcntl.h \
sys/fcntl.h \
+ sys/stat.h \
prot.h \
sia.h \
siad.h
--- /dev/null
+#!/usr/bin/env perl
+#
+# Print out the ATTRIBUTE's which are defined only once on input,
+# and any VALUE's which are defined for those attributes. It does NOT
+# print out unique VALUEs for multiple-defined attributes, though.
+#
+# Usage: cat dictionary1 dictionary2 | ./attrnew.pl > unique
+#
+# This is a bit of a hack. In order to make it work, you've got to
+# add a "fake" attribute to the end of dictionary1, so that you know
+# which attributes belong to which dictionary...
+#
+# $Id$
+#
+
+$line = 0;
+while (<>) {
+ $line++;
+
+ #
+ # Get attribute.
+ #
+ if (/^ATTRIBUTE\s+([\w-]+)\s+(\w+)\s+(\w+)(.*)/) {
+ $name=$1;
+ $value = $2;
+ $type = $3;
+ $stuff = $4;
+
+ $value =~ tr/[A-F]/[a-f]/; # normal form for hex
+ $value =~ tr/X/x/;
+
+ if ($value =~ /^0x/) {
+ $index = hex $value;
+ } else {
+ $index = $value;
+ }
+
+ if (defined $attributes{$index}) {
+ $dup{$index}++;
+ } else {
+ $first_ref{$line} = $index;
+ }
+
+ $attributes{$index} = "$name $value $type$stuff";
+ $name2val{$name} = $index;
+ next;
+ }
+
+ #
+ # Values.
+ #
+ if (/^VALUE\s+([\w-]+)\s+([\w-\/,.]+)\s+(\w+)(.*)/) {
+ $attr = $1;
+ $name = $2;
+ $value = $3;
+ $stuff = $d;
+
+ $value =~ tr/[A-F]/[a-f]/; # normal form for hex
+ $value =~ tr/X/x/;
+
+ if ($value =~ /^0x/) {
+ $index = hex $value;
+ } else {
+ $index = $value;
+ }
+
+ if (!defined $name2val{$attr}) {
+ print "# FIXME: FORWARD REF?\nVALUE $attr $name $value$stuff\n";
+ next;
+ }
+
+ $values{$name2val{$attr}}{$index} = "$attr $name $value$stuff";
+ next;
+ }
+}
+
+#
+# Print out the attributes sorted by number.
+#
+foreach $line (sort {$a <=> $b} keys %first_ref) {
+ $attr_val = $first_ref{$line};
+
+ next if (defined $dup{$attr_val});
+
+ print "ATTRIBUTE ", $attributes{$attr_val}, "\n";
+
+ next if (!defined %{$values{$attr_val}});
+
+ foreach $value (sort {$a <=> $b} keys %{$values{$attr_val}}) {
+ print "VALUE ", $values{$attr_val}{$value}, "\n";
+ }
+
+}
--- /dev/null
+#!/usr/bin/env perl
+#
+# Sort the attributes in a dictionary, and put them into a canonical
+# form. This will DESTROY any comments!
+#
+# Usage: cat dictionary | ./attrsort.pl > new
+#
+# This is a bit of a hack. The main purpose is to be able to quickly
+# "diff" two dictionaries which have significant differences...
+#
+# $Id$
+#
+
+while (<>) {
+ #
+ # Get attribute.
+ #
+ if (/^ATTRIBUTE\s+([\w-]+)\s+(\w+)\s+(\w+)(.*)/) {
+ $name=$1;
+ $value = $2;
+ $type = $3;
+ $stuff = $4;
+
+ $value =~ tr/[A-F]/[a-f]/; # normal form for hex
+ $value =~ tr/X/x/;
+
+ if ($value =~ /^0x/) {
+ $index = hex $value;
+ } else {
+ $index = $value;
+ }
+
+ $attributes{$index} = "$name $value $type$stuff";
+ $name2val{$name} = $index;
+ next;
+ }
+
+ #
+ # Values.
+ #
+ if (/^VALUE\s+([\w-]+)\s+([\w-\/,.]+)\s+(\w+)(.*)/) {
+ $attr = $1;
+ $name = $2;
+ $value = $3;
+ $stuff = $d;
+
+ $value =~ tr/[A-F]/[a-f]/; # normal form for hex
+ $value =~ tr/X/x/;
+
+ if ($value =~ /^0x/) {
+ $index = hex $value;
+ } else {
+ $index = $value;
+ }
+
+ if (!defined $name2val{$attr}) {
+ print "# FIXME: FORWARD REF?\nVALUE $attr $name $value$stuff\n";
+ next;
+ }
+
+ $values{$name2val{$attr}}{$index} = "$attr $name $value$stuff";
+ next;
+ }
+}
+
+#
+# Print out the attributes sorted by number.
+#
+foreach $attr_val (sort {$a <=> $b} keys %attributes) {
+ print "ATTRIBUTE ", $attributes{$attr_val}, "\n";
+}
+
+foreach $value (sort {$a <=> $b} keys %values) {
+ print $value, "\t", $attributes{$value}, "\n";
+}
+
+#
+# And again, this time printing out values.
+#
+foreach $attr_val (sort {$a <=> $b} keys %attributes) {
+
+ next if (!defined %{$values{$attr_val}});
+
+ foreach $value (sort {$a <=> $b} keys %{$values{$attr_val}}) {
+ print "VALUE ", $values{$attr_val}{$value}, "\n";
+ }
+}
+# -*- text -*-
#
# Version $Id$
#
# composed of Attribute/Value Pairs. The value of each attribute
# is specified as one of 4 data types. Valid data types are:
#
-# string - 0-253 octets
-# ipaddr - 4 octets in network byte order
-# integer - 32 bit value in big endian order (high byte first)
-# date - 32 bit value in big endian order - seconds since
-# 00:00:00 GMT, Jan. 1, 1970
-# ifid - 8 octets in network byte order
+# text - printable, generally UTF-8 encoded (subset of 'string')
+# string - 0-253 octets
+# ipaddr - 4 octets in network byte order
+# integer - 32 bit value in big endian order (high byte first)
+# date - 32 bit value in big endian order - seconds since
+# 00:00:00 GMT, Jan. 1, 1970
+# ifid - 8 octets in network byte order
# ipv6addr - 16 octets in network byte order
# ipv6prefix - 18 octets in network byte order
#
# FreeRADIUS includes extended data types which are not defined
-# in RFC 2865 or RFC 2866, or RFC 3162. These data types are:
+# in the RFC's. These data types are:
#
# abinary - Ascend's binary filter format.
# octets - raw octets, printed and input as hex strings.
#
#
-# Include compatibility dictionary for older users file. Move this
-# directive to the end of the file if you want to see the old names
-# in the logfiles, INSTEAD OF the new names.
+# Include compatibility dictionary for older users file. Move
+# this directive to the end of this file if you want to see the
+# old names in the logfiles, INSTEAD OF the new names.
+#
+$INCLUDE dictionary.compat
+
+#
+# Include the RFC dictionaries next.
+#
+# For a complete list of the standard attributes and values,
+# see:
+# http://www.iana.org/assignments/radius-types
+#
+$INCLUDE dictionary.rfc2865
+$INCLUDE dictionary.rfc2866
+$INCLUDE dictionary.rfc2867
+$INCLUDE dictionary.rfc2868
+$INCLUDE dictionary.rfc2869
+$INCLUDE dictionary.rfc3162
+$INCLUDE dictionary.rfc3576
+$INCLUDE dictionary.rfc3580
+
+#
+# Include vendor dictionaries after the standard ones.
#
-$INCLUDE dictionary.compat # compability issues
$INCLUDE dictionary.3com
$INCLUDE dictionary.3gpp
$INCLUDE dictionary.3gpp2
$INCLUDE dictionary.acc
+$INCLUDE dictionary.airespace
$INCLUDE dictionary.alcatel
$INCLUDE dictionary.alteon
+$INCLUDE dictionary.aruba
$INCLUDE dictionary.ascend
$INCLUDE dictionary.bay
$INCLUDE dictionary.bintec
+$INCLUDE dictionary.cablelabs
$INCLUDE dictionary.cabletron
$INCLUDE dictionary.cisco
#
-# This is the same as the altiga dictionary.
+# The Cisco VPN300 dictionary is the same as the altiga one.
+# You shouldn't use both at the same time.
#
#$INCLUDE dictionary.cisco.vpn3000
$INCLUDE dictionary.cisco.vpn5000
$INCLUDE dictionary.cisco.bbsm
$INCLUDE dictionary.colubris
+$INCLUDE dictionary.cosine
+$INCLUDE dictionary.epygi
$INCLUDE dictionary.erx
+$INCLUDE dictionary.ericsson
$INCLUDE dictionary.extreme
$INCLUDE dictionary.freeradius
$INCLUDE dictionary.foundry
$INCLUDE dictionary.gandalf
-$INCLUDE dictionary.garderos
+$INCLUDE dictionary.gemtek
+$INCLUDE dictionary.issanni
$INCLUDE dictionary.itk
+$INCLUDE dictionary.ipunplugged
$INCLUDE dictionary.juniper
$INCLUDE dictionary.karlnet
$INCLUDE dictionary.livingston
$INCLUDE dictionary.localweb
+$INCLUDE dictionary.lucent
$INCLUDE dictionary.microsoft
+$INCLUDE dictionary.mikrotik
$INCLUDE dictionary.navini
+$INCLUDE dictionary.netscreen
+$INCLUDE dictionary.ntua
$INCLUDE dictionary.nomadix
+$INCLUDE dictionary.packeteer
$INCLUDE dictionary.propel
$INCLUDE dictionary.quintum
$INCLUDE dictionary.redback
$INCLUDE dictionary.redcreek
+$INCLUDE dictionary.roaringpenguin
$INCLUDE dictionary.shasta
$INCLUDE dictionary.shiva
$INCLUDE dictionary.sonicwall
$INCLUDE dictionary.springtide
+$INCLUDE dictionary.starent
$INCLUDE dictionary.telebit
$INCLUDE dictionary.trapeze
-$INCLUDE dictionary.tunnel
+$INCLUDE dictionary.t_systems_nova
$INCLUDE dictionary.usr
$INCLUDE dictionary.valemount
$INCLUDE dictionary.versanet
+$INCLUDE dictionary.waverider
$INCLUDE dictionary.wispr
$INCLUDE dictionary.xedia
+$INCLUDE dictionary.xylan
#
-# The following are the proper new names. Use these.
-#
-# http://www.iana.org/assignments/radius-types
-#
-ATTRIBUTE User-Name 1 string
-ATTRIBUTE User-Password 2 string encrypt=1
-ATTRIBUTE CHAP-Password 3 octets
-ATTRIBUTE NAS-IP-Address 4 ipaddr
-ATTRIBUTE NAS-Port 5 integer
-ATTRIBUTE Service-Type 6 integer
-ATTRIBUTE Framed-Protocol 7 integer
-ATTRIBUTE Framed-IP-Address 8 ipaddr
-ATTRIBUTE Framed-IP-Netmask 9 ipaddr
-ATTRIBUTE Framed-Routing 10 integer
-ATTRIBUTE Filter-Id 11 string
-ATTRIBUTE Framed-MTU 12 integer
-ATTRIBUTE Framed-Compression 13 integer
-ATTRIBUTE Login-IP-Host 14 ipaddr
-ATTRIBUTE Login-Service 15 integer
-ATTRIBUTE Login-TCP-Port 16 integer
-ATTRIBUTE Reply-Message 18 string
-ATTRIBUTE Callback-Number 19 string
-ATTRIBUTE Callback-Id 20 string
-ATTRIBUTE Framed-Route 22 string
-ATTRIBUTE Framed-IPX-Network 23 ipaddr
-ATTRIBUTE State 24 octets
-ATTRIBUTE Class 25 octets
-ATTRIBUTE Vendor-Specific 26 octets
-ATTRIBUTE Session-Timeout 27 integer
-ATTRIBUTE Idle-Timeout 28 integer
-ATTRIBUTE Termination-Action 29 integer
-ATTRIBUTE Called-Station-Id 30 string
-ATTRIBUTE Calling-Station-Id 31 string
-ATTRIBUTE NAS-Identifier 32 string
-ATTRIBUTE Proxy-State 33 octets
-ATTRIBUTE Login-LAT-Service 34 string
-ATTRIBUTE Login-LAT-Node 35 string
-ATTRIBUTE Login-LAT-Group 36 octets
-ATTRIBUTE Framed-AppleTalk-Link 37 integer
-ATTRIBUTE Framed-AppleTalk-Network 38 integer
-ATTRIBUTE Framed-AppleTalk-Zone 39 string
-
-ATTRIBUTE Acct-Status-Type 40 integer
-ATTRIBUTE Acct-Delay-Time 41 integer
-ATTRIBUTE Acct-Input-Octets 42 integer
-ATTRIBUTE Acct-Output-Octets 43 integer
-ATTRIBUTE Acct-Session-Id 44 string
-ATTRIBUTE Acct-Authentic 45 integer
-ATTRIBUTE Acct-Session-Time 46 integer
-ATTRIBUTE Acct-Input-Packets 47 integer
-ATTRIBUTE Acct-Output-Packets 48 integer
-ATTRIBUTE Acct-Terminate-Cause 49 integer
-ATTRIBUTE Acct-Multi-Session-Id 50 string
-ATTRIBUTE Acct-Link-Count 51 integer
-ATTRIBUTE Acct-Input-Gigawords 52 integer
-ATTRIBUTE Acct-Output-Gigawords 53 integer
-ATTRIBUTE Event-Timestamp 55 date
-
-ATTRIBUTE CHAP-Challenge 60 octets
-ATTRIBUTE NAS-Port-Type 61 integer
-ATTRIBUTE Port-Limit 62 integer
-ATTRIBUTE Login-LAT-Port 63 integer
-
-ATTRIBUTE Acct-Tunnel-Connection 68 string
-
-ATTRIBUTE ARAP-Password 70 string
-ATTRIBUTE ARAP-Features 71 string
-ATTRIBUTE ARAP-Zone-Access 72 integer
-ATTRIBUTE ARAP-Security 73 integer
-ATTRIBUTE ARAP-Security-Data 74 string
-ATTRIBUTE Password-Retry 75 integer
-ATTRIBUTE Prompt 76 integer
-ATTRIBUTE Connect-Info 77 string
-ATTRIBUTE Configuration-Token 78 string
-ATTRIBUTE EAP-Message 79 octets
-ATTRIBUTE Message-Authenticator 80 octets
-ATTRIBUTE ARAP-Challenge-Response 84 string # 10 octets
-ATTRIBUTE Acct-Interim-Interval 85 integer
-ATTRIBUTE NAS-Port-Id 87 string
-ATTRIBUTE Framed-Pool 88 string
-ATTRIBUTE NAS-IPv6-Address 95 ipv6addr
-ATTRIBUTE Framed-Interface-Id 96 ifid
-ATTRIBUTE Framed-IPv6-Prefix 97 octets # ipv6prefix
-ATTRIBUTE Login-IPv6-Host 98 ipv6addr
-ATTRIBUTE Framed-IPv6-Route 99 string
-ATTRIBUTE Framed-IPv6-Pool 100 string
-
-# As defined in RFC 3576
-ATTRIBUTE Error-Cause 101 integer
-
-# As defined in draft-sterman-aaa-sip-00.txt
-ATTRIBUTE Digest-Response 206 string
-ATTRIBUTE Digest-Attributes 207 octets # stupid format
-
-#
-# Experimental Non Protocol Attributes used by FreeRADIUS
-#
-
-# The attributes number ranges are allocates as follows:
-#
-# Range: 500-999
-# server-side attributes which can go in a reply list
-
-# These attributes CAN go in the reply item list.
-ATTRIBUTE Fall-Through 500 integer
-ATTRIBUTE Exec-Program 502 string
-ATTRIBUTE Exec-Program-Wait 503 string
-
-# These attributes CANNOT go in the reply item list.
-
-#
-# Range: 1000+
-# Attributes which cannot go in a reply list.
-#
-#
-# Range: 1000-1199
-# Miscellaneous server attributes.
-#
-#
-# Non-Protocol Attributes
-# These attributes are used internally by the server
-#
-ATTRIBUTE Auth-Type 1000 integer
-ATTRIBUTE Menu 1001 string
-ATTRIBUTE Termination-Menu 1002 string
-ATTRIBUTE Prefix 1003 string
-ATTRIBUTE Suffix 1004 string
-ATTRIBUTE Group 1005 string
-ATTRIBUTE Crypt-Password 1006 string
-ATTRIBUTE Connect-Rate 1007 integer
-ATTRIBUTE Add-Prefix 1008 string
-ATTRIBUTE Add-Suffix 1009 string
-ATTRIBUTE Expiration 1010 date
-ATTRIBUTE Autz-Type 1011 integer
-ATTRIBUTE Acct-Type 1012 integer
-ATTRIBUTE Session-Type 1013 integer
-ATTRIBUTE Post-Auth-Type 1014 integer
-ATTRIBUTE Pre-Proxy-Type 1015 integer
-ATTRIBUTE Post-Proxy-Type 1016 integer
-ATTRIBUTE Pre-Acct-Type 1017 integer
-
-#
-# This is the EAP type of authentication, which is set
-# by the EAP module, for informational purposes only.
-#
-ATTRIBUTE EAP-Type 1018 integer
-ATTRIBUTE EAP-TLS-Require-Client-Cert 1019 integer
-ATTRIBUTE EAP-Id 1020 integer
-ATTRIBUTE EAP-Code 1021 integer
-ATTRIBUTE EAP-MD5-Password 1022 string
-#
-# Range: 1022-1028
-# unused
-#
-ATTRIBUTE User-Category 1029 string
-ATTRIBUTE Group-Name 1030 string
-ATTRIBUTE Huntgroup-Name 1031 string
-ATTRIBUTE Simultaneous-Use 1034 integer
-ATTRIBUTE Strip-User-Name 1035 integer
-ATTRIBUTE Hint 1040 string
-ATTRIBUTE Pam-Auth 1041 string
-ATTRIBUTE Login-Time 1042 string
-ATTRIBUTE Stripped-User-Name 1043 string
-ATTRIBUTE Current-Time 1044 string
-ATTRIBUTE Realm 1045 string
-ATTRIBUTE No-Such-Attribute 1046 string
-ATTRIBUTE Packet-Type 1047 integer
-ATTRIBUTE Proxy-To-Realm 1048 string
-ATTRIBUTE Replicate-To-Realm 1049 string
-ATTRIBUTE Acct-Session-Start-Time 1050 date
-ATTRIBUTE Acct-Unique-Session-Id 1051 string
-ATTRIBUTE Client-IP-Address 1052 ipaddr
-ATTRIBUTE Ldap-UserDn 1053 string
-ATTRIBUTE NS-MTA-MD5-Password 1054 string
-ATTRIBUTE SQL-User-Name 1055 string
-ATTRIBUTE LM-Password 1057 octets
-ATTRIBUTE NT-Password 1058 octets
-ATTRIBUTE SMB-Account-CTRL 1059 integer
-ATTRIBUTE SMB-Account-CTRL-TEXT 1061 string
-ATTRIBUTE User-Profile 1062 string
-ATTRIBUTE Digest-Realm 1063 string
-ATTRIBUTE Digest-Nonce 1064 string
-ATTRIBUTE Digest-Method 1065 string
-ATTRIBUTE Digest-URI 1066 string
-ATTRIBUTE Digest-QOP 1067 string
-ATTRIBUTE Digest-Algorithm 1068 string
-ATTRIBUTE Digest-Body-Digest 1069 string
-ATTRIBUTE Digest-CNonce 1070 string
-ATTRIBUTE Digest-Nonce-Count 1071 string
-ATTRIBUTE Digest-User-Name 1072 string
-ATTRIBUTE Pool-Name 1073 string
-ATTRIBUTE Ldap-Group 1074 string
-ATTRIBUTE Module-Success-Message 1075 string
-ATTRIBUTE Module-Failure-Message 1076 string
-# X99-Fast 1077 integer
-ATTRIBUTE Rewrite-Rule 1078 string
-ATTRIBUTE Sql-Group 1079 string
-ATTRIBUTE Response-Packet-Type 1080 integer
-ATTRIBUTE Packet-Dst-Port 1081 integer
-ATTRIBUTE MS-CHAP-Use-NTLM-Auth 1082 integer
-ATTRIBUTE NTLM-User-Name 1083 string
-
-#
-# Range: 1084-1199
-# unused.
-#
-
-#
-# Range: 1200-1279
-# EAP-SIM (and other EAP type) weirdness.
-#
-# For EAP-SIM, some attribute definitions for database interface
-#
-ATTRIBUTE EAP-Sim-Subtype 1200 integer
-
-ATTRIBUTE EAP-Sim-Rand1 1201 octets
-ATTRIBUTE EAP-Sim-Rand2 1202 octets
-ATTRIBUTE EAP-Sim-Rand3 1203 octets
-
-ATTRIBUTE EAP-Sim-SRES1 1204 octets
-ATTRIBUTE EAP-Sim-SRES2 1205 octets
-ATTRIBUTE EAP-Sim-SRES3 1206 octets
-
-VALUE EAP-Sim-Subtype Start 10
-VALUE EAP-Sim-Subtype Challenge 11
-VALUE EAP-Sim-Subtype Notification 12
-VALUE EAP-Sim-Subtype Re-authentication 13
-
-# this attribute is used internally by the client code.
-ATTRIBUTE EAP-Sim-State 1207 integer
-
-ATTRIBUTE EAP-Sim-IMSI 1208 string
-ATTRIBUTE EAP-Sim-HMAC 1209 string
-ATTRIBUTE EAP-Sim-KEY 1210 octets
-ATTRIBUTE EAP-Sim-EXTRA 1211 octets
-
-ATTRIBUTE EAP-Sim-KC1 1212 octets
-ATTRIBUTE EAP-Sim-KC2 1213 octets
-ATTRIBUTE EAP-Sim-KC3 1214 octets
-
-#
-# Range: 1280 - 1535
-# EAP-type specific attributes
-#
-
-# these are PW_EAP_X + 1280
-ATTRIBUTE EAP-Type-Identity 1281 string
-ATTRIBUTE EAP-Type-Notification 1282 string
-ATTRIBUTE EAP-Type-NAK 1283 string
-ATTRIBUTE EAP-Type-MD5 1284 octets
-ATTRIBUTE EAP-Type-OTP 1285 string
-ATTRIBUTE EAP-Type-GTC 1286 string
-ATTRIBUTE EAP-Type-TLS 1297 octets
-ATTRIBUTE EAP-Type-SIM 1298 octets
-ATTRIBUTE EAP-Type-LEAP 1301 octets
-ATTRIBUTE EAP-Type-SIM2 1302 octets
-ATTRIBUTE EAP-Type-TTLS 1305 octets
-ATTRIBUTE EAP-Type-PEAP 1309 octets
-
-#
-# Range: 1536 - 1791
-# EAP Sim sub-types.
+# And finally the server internal attributes.
#
-
-# these are PW_EAP_SIM_X + 1536
-ATTRIBUTE EAP-Sim-RAND 1537 octets
-ATTRIBUTE EAP-Sim-PADDING 1542 octets
-ATTRIBUTE EAP-Sim-NONCE_MT 1543 octets
-ATTRIBUTE EAP-Sim-PERMANENT_ID_REQ 1546 octets
-ATTRIBUTE EAP-Sim-MAC 1547 octets
-ATTRIBUTE EAP-Sim-NOTIFICATION 1548 octets
-ATTRIBUTE EAP-Sim-ANY_ID_REQ 1549 octets
-ATTRIBUTE EAP-Sim-IDENTITY 1550 octets
-ATTRIBUTE EAP-Sim-VERSION_LIST 1551 octets
-ATTRIBUTE EAP-Sim-SELECTED_VERSION 1552 octets
-ATTRIBUTE EAP-Sim-FULLAUTH_ID_REQ 1553 octets
-ATTRIBUTE EAP-Sim-COUNTER 1555 octets
-ATTRIBUTE EAP-Sim-COUNTER_TOO_SMALL 1556 octets
-ATTRIBUTE EAP-Sim-NONCE_S 1557 octets
-ATTRIBUTE EAP-Sim-IV 1665 octets
-ATTRIBUTE EAP-Sim-ENCR_DATA 1666 octets
-ATTRIBUTE EAP-Sim-NEXT_PSEUDONUM 1668 octets
-ATTRIBUTE EAP-Sim-NEXT_REAUTH_ID 1669 octets
-ATTRIBUTE EAP-Sim-CHECKCODE 1670 octets
-
+$INCLUDE dictionary.freeradius.internal
#
-# Range: 1800-2999
-# Free
-#
-# Range: 3000-3999
-# Site-local attributes (see raddb/dictionary.in)
-# Do NOT define attributes in this range!
-#
-# Range: 4000-65535
-# Unused
-#
-# Range: 65536-
-# Invalid. Don't use.
+# Miscellaneous attributes defined in weird places that
+# don't really belong anywhere else...
#
+ATTRIBUTE Originating-Line-Info 94 string
+# As defined in draft-sterman-aaa-sip-00.txt
+ATTRIBUTE Digest-Response 206 string
+ATTRIBUTE Digest-Attributes 207 octets # stupid format
#
# Integer Translations
#
+VALUE Service-Type Voice 12
+VALUE Service-Type Fax 13
+VALUE Service-Type Modem-Relay 14
+VALUE Service-Type IAPP-Register 15
+VALUE Service-Type IAPP-AP-Check 16
-# User Types
-
-VALUE Service-Type Login-User 1
-VALUE Service-Type Framed-User 2
-VALUE Service-Type Callback-Login-User 3
-VALUE Service-Type Callback-Framed-User 4
-VALUE Service-Type Outbound-User 5
-VALUE Service-Type Administrative-User 6
-VALUE Service-Type NAS-Prompt-User 7
-VALUE Service-Type Authenticate-Only 8
-VALUE Service-Type Callback-NAS-Prompt 9
-VALUE Service-Type Call-Check 10
-VALUE Service-Type Callback-Administrative 11
-VALUE Service-Type Voice 12
-VALUE Service-Type Fax 13
-VALUE Service-Type Modem-Relay 14
-VALUE Service-Type IAPP-Register 15
-VALUE Service-Type IAPP-AP-Check 16
-
-# Framed Protocols
-
-VALUE Framed-Protocol PPP 1
-VALUE Framed-Protocol SLIP 2
-VALUE Framed-Protocol ARAP 3
-VALUE Framed-Protocol Gandalf-SLML 4
-VALUE Framed-Protocol Xylogics-IPX-SLIP 5
-VALUE Framed-Protocol X.75-Synchronous 6
-VALUE Framed-Protocol GPRS-PDP-Context 7
-
-# Framed Routing Values
-
-VALUE Framed-Routing None 0
-VALUE Framed-Routing Broadcast 1
-VALUE Framed-Routing Listen 2
-VALUE Framed-Routing Broadcast-Listen 3
-
-# Framed Compression Types
-
-VALUE Framed-Compression None 0
-VALUE Framed-Compression Van-Jacobson-TCP-IP 1
-VALUE Framed-Compression IPX-Header-Compression 2
-VALUE Framed-Compression Stac-LZS 3
-
-# Login Services
+VALUE Framed-Protocol GPRS-PDP-Context 7
-VALUE Login-Service Telnet 0
-VALUE Login-Service Rlogin 1
-VALUE Login-Service TCP-Clear 2
-VALUE Login-Service PortMaster 3
-VALUE Login-Service LAT 4
-VALUE Login-Service X25-PAD 5
-VALUE Login-Service X25-T3POS 6
-VALUE Login-Service TCP-Clear-Quiet 7
+VALUE NAS-Port-Type Wireless-CDMA2000 22
+VALUE NAS-Port-Type Wireless-UMTS 23
+VALUE NAS-Port-Type Wireless-1X-EV 24
+VALUE NAS-Port-Type IAPP 25
-# Login-TCP-Port (see /etc/services for more examples)
-
-VALUE Login-TCP-Port Telnet 23
-VALUE Login-TCP-Port Rlogin 513
-VALUE Login-TCP-Port Rsh 514
-
-# Status Types
-
-VALUE Acct-Status-Type Start 1
-VALUE Acct-Status-Type Stop 2
-VALUE Acct-Status-Type Interim-Update 3
-VALUE Acct-Status-Type Alive 3
-VALUE Acct-Status-Type Accounting-On 7
-VALUE Acct-Status-Type Accounting-Off 8
-# RFC 2867 Additional Status-Type Values
-VALUE Acct-Status-Type Tunnel-Start 9
-VALUE Acct-Status-Type Tunnel-Stop 10
-VALUE Acct-Status-Type Tunnel-Reject 11
-VALUE Acct-Status-Type Tunnel-Link-Start 12
-VALUE Acct-Status-Type Tunnel-Link-Stop 13
-VALUE Acct-Status-Type Tunnel-Link-Reject 14
-VALUE Acct-Status-Type Failed 15
-
-# Authentication Types
-
-VALUE Acct-Authentic RADIUS 1
-VALUE Acct-Authentic Local 2
-VALUE Acct-Authentic Remote 3
-VALUE Acct-Authentic Diameter 4
-
-# Termination Options
-
-VALUE Termination-Action Default 0
-VALUE Termination-Action RADIUS-Request 1
-
-# NAS Port Types
-
-VALUE NAS-Port-Type Async 0
-VALUE NAS-Port-Type Sync 1
-VALUE NAS-Port-Type ISDN 2
-VALUE NAS-Port-Type ISDN-V120 3
-VALUE NAS-Port-Type ISDN-V110 4
-VALUE NAS-Port-Type Virtual 5
-VALUE NAS-Port-Type PIAFS 6
-VALUE NAS-Port-Type HDLC-Clear-Channel 7
-VALUE NAS-Port-Type X.25 8
-VALUE NAS-Port-Type X.75 9
-VALUE NAS-Port-Type G.3-Fax 10
-VALUE NAS-Port-Type SDSL 11
-VALUE NAS-Port-Type ADSL-CAP 12
-VALUE NAS-Port-Type ADSL-DMT 13
-VALUE NAS-Port-Type IDSL 14
-VALUE NAS-Port-Type Ethernet 15
-VALUE NAS-Port-Type xDSL 16
-VALUE NAS-Port-Type Cable 17
-VALUE NAS-Port-Type Wireless-Other 18
-VALUE NAS-Port-Type Wireless-802.11 19
-VALUE NAS-Port-Type Token-Ring 20
-VALUE NAS-Port-Type FDDI 21
-VALUE NAS-Port-Type Wireless-CDMA2000 22
-VALUE NAS-Port-Type Wireless-UMTS 23
-VALUE NAS-Port-Type Wireless-1X-EV 24
-VALUE NAS-Port-Type IAPP 25
-
-# Acct Terminate Causes
-
-VALUE Acct-Terminate-Cause User-Request 1
-VALUE Acct-Terminate-Cause Lost-Carrier 2
-VALUE Acct-Terminate-Cause Lost-Service 3
-VALUE Acct-Terminate-Cause Idle-Timeout 4
-VALUE Acct-Terminate-Cause Session-Timeout 5
-VALUE Acct-Terminate-Cause Admin-Reset 6
-VALUE Acct-Terminate-Cause Admin-Reboot 7
-VALUE Acct-Terminate-Cause Port-Error 8
-VALUE Acct-Terminate-Cause NAS-Error 9
-VALUE Acct-Terminate-Cause NAS-Request 10
-VALUE Acct-Terminate-Cause NAS-Reboot 11
-VALUE Acct-Terminate-Cause Port-Unneeded 12
-VALUE Acct-Terminate-Cause Port-Preempted 13
-VALUE Acct-Terminate-Cause Port-Suspended 14
-VALUE Acct-Terminate-Cause Service-Unavailable 15
-VALUE Acct-Terminate-Cause Callback 16
-VALUE Acct-Terminate-Cause User-Error 17
-VALUE Acct-Terminate-Cause Host-Request 18
-VALUE Acct-Terminate-Cause Supplicant-Restart 19
-VALUE Acct-Terminate-Cause Reauthentication-Failure 20
-VALUE Acct-Terminate-Cause Port-Reinit 21
-VALUE Acct-Terminate-Cause Port-Disabled 22
-
-#VALUE Tunnel-Type L2TP 3
-#VALUE Tunnel-Medium-Type IP 1
-
-VALUE Prompt No-Echo 0
-VALUE Prompt Echo 1
-
-#
-# Error causes
-#
-VALUE Error-Cause Residual-Context-Removed 201
-VALUE Error-Cause Invalid-EAP-Packet 202
-VALUE Error-Cause Unsupported-Attribute 401
-VALUE Error-Cause Missing-Attribute 402
-VALUE Error-Cause NAS-Identification-Mismatch 403
-VALUE Error-Cause Invalid-Request 404
-VALUE Error-Cause Unsupported-Service 405
-VALUE Error-Cause Unsupported-Extension 406
-VALUE Error-Cause Administratively-Prohibited 501
-VALUE Error-Cause Proxy-Request-Not-Routable 502
-VALUE Error-Cause Session-Context-Not-Found 503
-VALUE Error-Cause Session-Context-Not-Removable 504
-VALUE Error-Cause Proxy-Processing-Error 505
-VALUE Error-Cause Resources-Unavailable 506
-VALUE Error-Cause Request-Initiated 507
-
-#
-# Non-Protocol Integer Translations
-#
-
-VALUE Auth-Type Local 0
-VALUE Auth-Type System 1
-VALUE Auth-Type SecurID 2
-VALUE Auth-Type Crypt-Local 3
-VALUE Auth-Type Reject 4
-VALUE Auth-Type ActivCard 5
-VALUE Auth-Type EAP 6
-VALUE Auth-Type ARAP 7
-
-#
-# FreeRADIUS extensions (most originally from Cistron)
-#
-VALUE Auth-Type Accept 254
-
-VALUE Auth-Type PAP 1024
-VALUE Auth-Type CHAP 1025
-VALUE Auth-Type LDAP 1026
-VALUE Auth-Type PAM 1027
-VALUE Auth-Type MS-CHAP 1028
-VALUE Auth-Type Kerberos 1029
-VALUE Auth-Type CRAM 1030
-VALUE Auth-Type NS-MTA-MD5 1031
-# 1032 is unused (was a duplicate of CRAM)
-VALUE Auth-Type SMB 1033
-
-#
-# Authorization type, too.
-#
-VALUE Autz-Type Local 0
-
-#
-# And accounting
-#
-VALUE Acct-Type Local 0
-
-#
-# And Session handling
-#
-VALUE Session-Type Local 0
-
-#
-# And Post-Auth
-VALUE Post-Auth-Type Local 0
-
-#
-# Experimental Non-Protocol Integer Translations for FreeRADIUS
-#
-VALUE Fall-Through No 0
-VALUE Fall-Through Yes 1
-
-VALUE Packet-Type Access-Request 1
-VALUE Packet-Type Access-Accept 2
-VALUE Packet-Type Access-Reject 3
-VALUE Packet-Type Accounting-Request 4
-VALUE Packet-Type Accounting-Response 5
-VALUE Packet-Type Accounting-Status 6
-VALUE Packet-Type Password-Request 7
-VALUE Packet-Type Password-Accept 8
-VALUE Packet-Type Password-Reject 9
-VALUE Packet-Type Accounting-Message 10
-VALUE Packet-Type Access-Challenge 11
-VALUE Packet-Type Status-Server 12
-VALUE Packet-Type Status-Client 13
-
-#
-# Defined in RFC 2882
-#
-VALUE Packet-Type Disconnect-Request 40
-VALUE Packet-Type Disconnect-ACK 41
-VALUE Packet-Type Disconnect-NAK 42
-VALUE Packet-Type CoA-Request 43
-VALUE Packet-Type CoA-ACK 44
-VALUE Packet-Type CoA-NAK 45
-
-#
-# The following packet types are described in RFC 2882,
-# but they are NOT part of the RADIUS standard. Instead,
-# they are informational about vendor-specific extensions
-# to the RADIUS standard.
-#
-VALUE Packet-Type Resource-Free-Request 21
-VALUE Packet-Type Resource-Free-Response 22
-VALUE Packet-Type Resource-Query-Request 23
-VALUE Packet-Type Resource-Query-Response 24
-VALUE Packet-Type Alternate-Resource-Reclaim-Request 25
-VALUE Packet-Type NAS-Reboot-Request 26
-VALUE Packet-Type NAS-Reboot-Response 27
-VALUE Packet-Type Next-Passcode 29
-VALUE Packet-Type New-Pin 30
-VALUE Packet-Type Terminate-Session 31
-VALUE Packet-Type Password-Expired 32
-VALUE Packet-Type Event-Request 33
-VALUE Packet-Type Event-Response 34
-VALUE Packet-Type Disconnect-Request 40
-VALUE Packet-Type Disconnect-ACK 41
-VALUE Packet-Type Disconnect-NAK 42
-VALUE Packet-Type CoF-Request 43
-VALUE Packet-Type CoF-ACK 44
-VALUE Packet-Type CoF-NAK 45
-VALUE Packet-Type IP-Address-Allocate 50
-VALUE Packet-Type IP-Address-Release 51
-
-VALUE Response-Packet-Type Access-Request 1
-VALUE Response-Packet-Type Access-Accept 2
-VALUE Response-Packet-Type Access-Reject 3
-VALUE Response-Packet-Type Accounting-Request 4
-VALUE Response-Packet-Type Accounting-Response 5
-VALUE Response-Packet-Type Accounting-Status 6
-VALUE Response-Packet-Type Password-Request 7
-VALUE Response-Packet-Type Password-Accept 8
-VALUE Response-Packet-Type Password-Reject 9
-VALUE Response-Packet-Type Accounting-Message 10
-VALUE Response-Packet-Type Access-Challenge 11
-VALUE Response-Packet-Type Status-Server 12
-VALUE Response-Packet-Type Status-Client 13
-
-#
-# EAP Sub-types, inside of Request and Response packets
-#
-# http://www.iana.org/assignments/ppp-numbers
-# "PPP EAP REQUEST/RESPONSE TYPES"
-#
-#
-# See dictionary.microsoft, MS-Acct-EAP-Type for similar definitions
-#
-VALUE EAP-Type None 0
-VALUE EAP-Type Identity 1
-VALUE EAP-Type Notification 2
-VALUE EAP-Type NAK 3
-VALUE EAP-Type MD5-Challenge 4
-VALUE EAP-Type One-Time-Password 5
-VALUE EAP-Type Generic-Token-Card 6
-VALUE EAP-Type RSA-Public-Key 9
-VALUE EAP-Type DSS-Unilateral 10
-VALUE EAP-Type KEA 11
-VALUE EAP-Type KEA-Validate 12
-VALUE EAP-Type KEA 11
-VALUE EAP-Type EAP-TLS 13
-VALUE EAP-Type Defender-Token 14
-VALUE EAP-Type RSA-SecurID-EAP 15
-VALUE EAP-Type Arcot-Systems-EAP 16
-VALUE EAP-Type Cisco-LEAP 17
-VALUE EAP-Type Nokia-IP-Smart-Card 18
-VALUE EAP-Type SIM 18
-VALUE EAP-Type SRP-SHA1-Part-1 19
-VALUE EAP-Type SRP-SHA1-Part-2 20
-VALUE EAP-Type EAP-TTLS 21
-VALUE EAP-Type Remote-Access-Service 22
-VALUE EAP-Type UMTS 23
-VALUE EAP-Type EAP-3Com-Wireless 24
-VALUE EAP-Type PEAP 25
-VALUE EAP-Type MS-EAP-Authentication 26
-VALUE EAP-Type MAKE 27
-VALUE EAP-Type CRYPTOCard 28
-VALUE EAP-Type EAP-MSCHAP-V2 29
-VALUE EAP-Type DynamID 30
-VALUE EAP-Type Rob-EAP 31
-VALUE EAP-Type SecurID-EAP 32
-VALUE EAP-Type MS-Authentication-TLV 33
-VALUE EAP-Type SentriNET 34
-VALUE EAP-Type EAP-Actiontec-Wireless 35
-VALUE EAP-Type Cogent-Biomentric-EAP 36
-VALUE EAP-Type AirFortress-EAP 37
-VALUE EAP-Type EAP-HTTP-Digest 38
-VALUE EAP-Type SecuriSuite-EAP 39
-VALUE EAP-Type DeviceConnect-EAP 40
-VALUE EAP-Type EAP-SPEKE 41
-VALUE EAP-Type EAP-MOBAC 42
-
-#
-# These are duplicate values, to get around the problem of
-# having two MS-CHAPv2 EAP types.
-#
-VALUE EAP-Type Microsoft-MS-CHAPv2 26
-VALUE EAP-Type Cisco-MS-CHAPv2 29
-
-#
-# And this is what most people mean by MS-CHAPv2
-#
-VALUE EAP-Type MS-CHAP-V2 26
-
-
-#
-# This says TLS, but it's only valid for TTLS & PEAP.
-# EAP-TLS *always* requires a client certificate.
-#
-VALUE EAP-TLS-Require-Client-Cert No 0
-VALUE EAP-TLS-Require-Client-Cert Yes 1
-
-#
-# These are the EAP-Code values.
-#
-VALUE EAP-Code Request 1
-VALUE EAP-Code Response 2
-VALUE EAP-Code Success 3
-VALUE EAP-Code Failure 4
-
-#
-# For MS-CHAP, do we run ntlm_auth, or not.
-#
-VALUE MS-CHAP-Use-NTLM-Auth No 0
-VALUE MS-CHAP-Use-NTLM-Auth Yes 1
+VALUE Framed-Protocol PPTP 9
+# -*- text -*-
#
# 3com SuperStack Firewall dictionary
# Bought from Sonicwall, apparently, from Enterprise number 8741.
# $Id$
#
-VENDOR 3com 43
+VENDOR 3com 43
#
# These attributes contain the access-level value.
#
-ATTRIBUTE 3Com-User-Access-Level 1 integer 3com
+BEGIN-VENDOR 3com
+
+ATTRIBUTE 3Com-User-Access-Level 1 integer
# Read-only access to manageable (not security) parameters
-VALUE 3Com-User-Access-Level 3Com-Monitor 1
+VALUE 3Com-User-Access-Level 3Com-Monitor 1
# Read-write access to manageable (not security) parameters
-VALUE 3Com-User-Access-Level 3Com-Manager 2
+VALUE 3Com-User-Access-Level 3Com-Manager 2
# Read-write access to all manageable parameters
-VALUE 3Com-User-Access-Level 3Com-Administrator 3
+VALUE 3Com-User-Access-Level 3Com-Administrator 3
+
+END-VENDOR 3com
+# -*- text -*-
#
# 3GPP stuff.
#
#
# $Id$
#
-VENDOR 3GPP 10415
+VENDOR 3GPP 10415
BEGIN-VENDOR 3GPP
# Most of the 'string' attributes are UTF-8 encoded text.
# Maybe we want a UTF-8 'type' in the server...
#
-ATTRIBUTE 3GPP-IMSI 1 string
-ATTRIBUTE 3GPP-Charging-ID 2 integer
-ATTRIBUTE 3GPP-PDP-Type 3 integer
-ATTRIBUTE 3GPP-Charging-Gateway-Address 4 ipaddr
-ATTRIBUTE 3GPP-GPRS-Negotiated-QoS-profile 5 string
-ATTRIBUTE 3GPP-SGSN-Address 6 ipaddr
-ATTRIBUTE 3GPP-GGSN-Address 7 ipaddr
-ATTRIBUTE 3GPP-IMSI-MCC-MNC 8 string
-ATTRIBUTE 3GPP-GGSN-MCC-MNC 9 string
-ATTRIBUTE 3GPP-NSAPI 10 string
-ATTRIBUTE 3GPP-Session-Stop-Indicator 11 octets
-ATTRIBUTE 3GPP-Selection-Mode 12 string
-ATTRIBUTE 3GPP-Charging-Characteristics 13 string
-ATTRIBUTE 3GPP-Charging-Gateway-IPv6-Address 14 ipv6addr
-ATTRIBUTE 3GPP-SGSN-IPv6-Address 15 ipv6addr
-ATTRIBUTE 3GPP-GGSN-IPv6-Address 16 ipv6addr
+ATTRIBUTE 3GPP-IMSI 1 string
+ATTRIBUTE 3GPP-Charging-ID 2 integer
+ATTRIBUTE 3GPP-PDP-Type 3 integer
+ATTRIBUTE 3GPP-Charging-Gateway-Address 4 ipaddr
+ATTRIBUTE 3GPP-GPRS-Negotiated-QoS-profile 5 string
+ATTRIBUTE 3GPP-SGSN-Address 6 ipaddr
+ATTRIBUTE 3GPP-GGSN-Address 7 ipaddr
+ATTRIBUTE 3GPP-IMSI-MCC-MNC 8 string
+ATTRIBUTE 3GPP-GGSN-MCC-MNC 9 string
+ATTRIBUTE 3GPP-NSAPI 10 string
+ATTRIBUTE 3GPP-Session-Stop-Indicator 11 octets
+ATTRIBUTE 3GPP-Selection-Mode 12 string
+ATTRIBUTE 3GPP-Charging-Characteristics 13 string
+ATTRIBUTE 3GPP-Charging-Gateway-IPv6-Address 14 ipv6addr
+ATTRIBUTE 3GPP-SGSN-IPv6-Address 15 ipv6addr
+ATTRIBUTE 3GPP-GGSN-IPv6-Address 16 ipv6addr
#
# This attribute is really an array of IPv6 addresses.
# Why the heck couldn't they just send multiple attributes?
#
-ATTRIBUTE 3GPP-IPv6-DNS-Servers 17 octets
+ATTRIBUTE 3GPP-IPv6-DNS-Servers 17 octets
+
+ATTRIBUTE 3GPP-SGSN-MCC-MNC 18 string
+ATTRIBUTE 3GPP-Teardown-Indicator 19 octets
END-VENDOR 3GPP
+# -*- text -*-
#
# 3GPP2 stuff.
#
# http://www.3gpp2.org/Public_html/specs/index.cfm
# X.S0011-005-C v1.0
+# http://www.3gpp2.org/Public_html/specs/X.S0011-005-C_v2.0_050708.pdf
#
# $Id$
#
-VENDOR 3GPP2 5535
+VENDOR 3GPP2 5535
BEGIN-VENDOR 3GPP2
-ATTRIBUTE 3GPP2-Ike-Preshared-Secret-Request 1 integer
-ATTRIBUTE 3GPP2-Security-Level 2 integer
-ATTRIBUTE 3GPP2-Pre-Shared-Secret 3 string # 18 octets
-ATTRIBUTE 3GPP2-Reverse-Tunnel-Spec 4 integer
-ATTRIBUTE 3GPP2-Diffserv-Class-Option 5 integer
+ATTRIBUTE 3GPP2-Ike-Preshared-Secret-Request 1 integer
+ATTRIBUTE 3GPP2-Security-Level 2 integer
+ATTRIBUTE 3GPP2-Pre-Shared-Secret 3 string # 18 octets
+ATTRIBUTE 3GPP2-Reverse-Tunnel-Spec 4 integer
+ATTRIBUTE 3GPP2-Diffserv-Class-Option 5 integer
# Contains embedded 3GPP2 accounting attributes.
-ATTRIBUTE 3GPP2-Accounting-Container 6 octets
-ATTRIBUTE 3GPP2-Home-Agent-IP-Address 7 ipaddr
+ATTRIBUTE 3GPP2-Accounting-Container 6 octets
+ATTRIBUTE 3GPP2-Home-Agent-IP-Address 7 ipaddr
# A number formed from the concatenation of the home RADIUS IP address,
# the FA IP address, and a 32-bit Unix timestamp, all encoded as 8 ASCII
# hex characters.
-ATTRIBUTE 3GPP2-KeyID 8 string # 22 octets
+ATTRIBUTE 3GPP2-KeyID 8 string # 22 octets
-ATTRIBUTE 3GPP2-PCF-IP-Address 9 ipaddr
-ATTRIBUTE 3GPP2-BSID 10 string
-ATTRIBUTE 3GPP2-User-Id 11 integer
-ATTRIBUTE 3GPP2-Forward-FCH-Mux-Option 12 integer
-ATTRIBUTE 3GPP2-Reverse-FCH-Mux-Option 13 integer
+ATTRIBUTE 3GPP2-PCF-IP-Address 9 ipaddr
+ATTRIBUTE 3GPP2-BSID 10 string
+ATTRIBUTE 3GPP2-User-Id 11 integer
+ATTRIBUTE 3GPP2-Forward-FCH-Mux-Option 12 integer
+ATTRIBUTE 3GPP2-Reverse-FCH-Mux-Option 13 integer
#
# 14-15 ?
#
-ATTRIBUTE 3GPP2-Service-Option 16 integer
-ATTRIBUTE 3GPP2-Forward-Traffic-Type 17 integer
-ATTRIBUTE 3GPP2-Reverse-Traffic-Type 18 integer
-ATTRIBUTE 3GPP2-FCH-Frame-Size 19 integer
-ATTRIBUTE 3GPP2-Forward-FCH-RC 20 integer
-ATTRIBUTE 3GPP2-Reverse-FCH-RC 21 integer
-ATTRIBUTE 3GPP2-IP-Technology 22 integer
-ATTRIBUTE 3GPP2-Compulsory-Tunnel-Indicator 23 integer
-ATTRIBUTE 3GPP2-Release-Indicator 24 integer
-ATTRIBUTE 3GPP2-Bad-PPP-Frame-Count 25 integer
+ATTRIBUTE 3GPP2-Service-Option 16 integer
+ATTRIBUTE 3GPP2-Forward-Traffic-Type 17 integer
+ATTRIBUTE 3GPP2-Reverse-Traffic-Type 18 integer
+ATTRIBUTE 3GPP2-FCH-Frame-Size 19 integer
+ATTRIBUTE 3GPP2-Forward-FCH-RC 20 integer
+ATTRIBUTE 3GPP2-Reverse-FCH-RC 21 integer
+ATTRIBUTE 3GPP2-IP-Technology 22 integer
+ATTRIBUTE 3GPP2-Compulsory-Tunnel-Indicator 23 integer
+ATTRIBUTE 3GPP2-Release-Indicator 24 integer
+ATTRIBUTE 3GPP2-Bad-PPP-Frame-Count 25 integer
#
# 26-29 ?
#
-ATTRIBUTE 3GPP2-Number-Active-Transitions 30 integer
-ATTRIBUTE 3GPP2-Terminating-SDB-Octet-Count 31 integer
-ATTRIBUTE 3GPP2-Originating-SDB-OCtet-Count 32 integer
-ATTRIBUTE 3GPP2-Terminating-Number-SDBs 33 integer
-ATTRIBUTE 3GPP2-Originating-Number-SDBs 34 integer
+ATTRIBUTE 3GPP2-Number-Active-Transitions 30 integer
+ATTRIBUTE 3GPP2-Terminating-SDB-Octet-Count 31 integer
+ATTRIBUTE 3GPP2-Originating-SDB-OCtet-Count 32 integer
+ATTRIBUTE 3GPP2-Terminating-Number-SDBs 33 integer
+ATTRIBUTE 3GPP2-Originating-Number-SDBs 34 integer
# 35 ?
-ATTRIBUTE 3GPP2-IP-QoS 36 integer
+ATTRIBUTE 3GPP2-IP-QoS 36 integer
# 37-38 ?
-ATTRIBUTE 3GPP2-Airlink-Priority 39 integer
-ATTRIBUTE 3GPP2-Airlink-Record-Type 40 integer # ?
-# 41 ?
-ATTRIBUTE 3GPP2-Airlink-Sequence-Number 42 integer # ?
-ATTRIBUTE 3GPP2-Received-HDLC-Octets 43 integer
-ATTRIBUTE 3GPP2-Correlation-Id 44 string
-ATTRIBUTE 3GPP2-Module-Orig-Term-Indicator 45 octets # ?
-ATTRIBUTE 3GPP2-Inbound-Mobile-IP-Sig-Octets 46 integer
-ATTRIBUTE 3GPP2-Outbound-Mobile-IP-Sig-Octets 47 integer
-ATTRIBUTE 3GPP2-Session-Continue 48 integer
-ATTRIBUTE 3GPP2-Active-Time 49 integer
-ATTRIBUTE 3GPP2-DCCH-Frame-Size 50 integer
-ATTRIBUTE 3GPP2-Begin-Session 51 integer
-ATTRIBUTE 3GPP2-ESN 52 string
+ATTRIBUTE 3GPP2-Airlink-Priority 39 integer
+ATTRIBUTE 3GPP2-Airlink-Record-Type 40 integer # ?
+#ATTRIBUTE 3GPP2-R-P-Session-ID 41 string
+ATTRIBUTE 3GPP2-Airlink-Sequence-Number 42 integer # ?
+ATTRIBUTE 3GPP2-Received-HDLC-Octets 43 integer
+ATTRIBUTE 3GPP2-Correlation-Id 44 string
+ATTRIBUTE 3GPP2-Module-Orig-Term-Indicator 45 octets # ?
+ATTRIBUTE 3GPP2-Inbound-Mobile-IP-Sig-Octets 46 integer
+ATTRIBUTE 3GPP2-Outbound-Mobile-IP-Sig-Octets 47 integer
+ATTRIBUTE 3GPP2-Session-Continue 48 integer
+ATTRIBUTE 3GPP2-Active-Time 49 integer
+ATTRIBUTE 3GPP2-DCCH-Frame-Size 50 integer
+ATTRIBUTE 3GPP2-Begin-Session 51 integer
+ATTRIBUTE 3GPP2-ESN 52 string
# 53 ?
-ATTRIBUTE 3GPP2-S-Key 54 octets
-ATTRIBUTE 3GPP2-S-Request 55 integer
-ATTRIBUTE 3GPP2-S-Lifetime 56 date
-ATTRIBUTE 3GPP2-MN-HA-SPI 57 integer
-ATTRIBUTE 3GPP2-MN-HA-Shared-Key 58 string encrypt=2
+ATTRIBUTE 3GPP2-S-Key 54 octets
+ATTRIBUTE 3GPP2-S-Request 55 integer
+ATTRIBUTE 3GPP2-S-Lifetime 56 date
+ATTRIBUTE 3GPP2-MN-HA-SPI 57 integer
+ATTRIBUTE 3GPP2-MN-HA-Shared-Key 58 string encrypt=2
# The next set of attributes contain sub-types
-ATTRIBUTE 3GPP2-Remote-IP-Address 59 octets
+ATTRIBUTE 3GPP2-Remote-IP-Address 59 octets
# 60 - 69 are marked "reserved"
-ATTRIBUTE 3GPP2-Remote-IPv6-Address 70 octets
-ATTRIBUTE 3GPP2-Remote-Address-Table-Index 71 octets
-ATTRIBUTE 3GPP2-Remote-IPv4-Addr-Octet-Count 72 octets
-ATTRIBUTE 3GPP2-Allowed-Diffserv-Marking 73 octets
-ATTRIBUTE 3GPP2-Service-Option-Profile 74 octets
+ATTRIBUTE 3GPP2-Remote-IPv6-Address 70 octets
+ATTRIBUTE 3GPP2-Remote-Address-Table-Index 71 octets
+ATTRIBUTE 3GPP2-Remote-IPv4-Addr-Octet-Count 72 octets
+ATTRIBUTE 3GPP2-Allowed-Diffserv-Marking 73 octets
+ATTRIBUTE 3GPP2-Service-Option-Profile 74 octets
# the following don't contain subtypes
-ATTRIBUTE 3GPP2-DNS-Update-Required 75 integer
+ATTRIBUTE 3GPP2-DNS-Update-Required 75 integer
# Is this 76 or 78? Check...
#ATTRIBUTE 3GPP2-Always-On 76 integer
# 77 ?
#ATTRIBUTE 3GPP2-Always-On 78 integer
-ATTRIBUTE 3GPP2-Foreign-Agent-Address 79 ipaddr
-ATTRIBUTE 3GPP2-Last-User-Activity-Time 80 integer
-ATTRIBUTE 3GPP2-MN-AAA-Removal-Indication 81 integer
-ATTRIBUTE 3GPP2-RN-Packet-Data-Inactivity-Timer 82 integer
-ATTRIBUTE 3GPP2-Forward-PDCH-RC 83 integer
-ATTRIBUTE 3GPP2-Forward-DCCH-Mux-Option 84 integer
-ATTRIBUTE 3GPP2-Reverse-DCCH-Mux-Option 85 integer
-ATTRIBUTE 3GPP2-Forward-DCCH-RC 86 integer
-ATTRIBUTE 3GPP2-Reverse-DHHC-RC 87 integer
-ATTRIBUTE 3GPP2-Session-Termination-Capability 88 integer
-ATTRIBUTE 3GPP2-Allowed-Persistent-TFTs 89 integer
+ATTRIBUTE 3GPP2-Foreign-Agent-Address 79 ipaddr
+ATTRIBUTE 3GPP2-Last-User-Activity-Time 80 integer
+ATTRIBUTE 3GPP2-MN-AAA-Removal-Indication 81 integer
+ATTRIBUTE 3GPP2-RN-Packet-Data-Inactivity-Timer 82 integer
+ATTRIBUTE 3GPP2-Forward-PDCH-RC 83 integer
+ATTRIBUTE 3GPP2-Forward-DCCH-Mux-Option 84 integer
+ATTRIBUTE 3GPP2-Reverse-DCCH-Mux-Option 85 integer
+ATTRIBUTE 3GPP2-Forward-DCCH-RC 86 integer
+ATTRIBUTE 3GPP2-Reverse-DHHC-RC 87 integer
+ATTRIBUTE 3GPP2-Session-Termination-Capability 88 integer
+ATTRIBUTE 3GPP2-Allowed-Persistent-TFTs 89 integer
# The next set of attributes contain sub-types
-ATTRIBUTE 3GPP2-Prepaid-Acct-Quota 90 octets
-ATTRIBUTE 3GPP2-Prepaid-acct-Capability 91 octets
-ATTRIBUTE 3GPP2-MIP-Lifetime 92 octets
+ATTRIBUTE 3GPP2-Prepaid-Acct-Quota 90 octets
+ATTRIBUTE 3GPP2-Prepaid-acct-Capability 91 octets
+ATTRIBUTE 3GPP2-MIP-Lifetime 92 octets
-ATTRIBUTE 3GPP2-Acct-Stop-Trigger 93 integer
+ATTRIBUTE 3GPP2-Acct-Stop-Trigger 93 integer
# contains subtypes
-ATTRIBUTE 3GPP2-Service-Reference-Id 94 octets
+ATTRIBUTE 3GPP2-Service-Reference-Id 94 octets
-ATTRIBUTE 3GPP2-DNS-Update-Capability 95 integer
-ATTRIBUTE 3GPP2-Disconnect-Reason 96 integer
+ATTRIBUTE 3GPP2-DNS-Update-Capability 95 integer
+ATTRIBUTE 3GPP2-Disconnect-Reason 96 integer
# The next set of attributes contain sub-types
-ATTRIBUTE 3GPP2-Remote-IPv6-Octet-Count 97 octets
-ATTRIBUTE 3GPP2-PrePaid-Tariff-Switching 98 octets
+ATTRIBUTE 3GPP2-Remote-IPv6-Octet-Count 97 octets
+ATTRIBUTE 3GPP2-PrePaid-Tariff-Switching 98 octets
END-VENDOR 3GPP2
+# -*- text -*-
#
# dictionary.acc
# Dictionary for Acc/Newbridge, models Tigris, Amazon, etc.
# Version: @(#)dictionary.acc 1.00 smarzloff 21-Jun-1999
#
-VENDOR Acc 5
+VENDOR Acc 5
#
# Acc specific
-ATTRIBUTE Acc-Reason-Code 1 integer Acc
-ATTRIBUTE Acc-Ccp-Option 2 integer Acc
-ATTRIBUTE Acc-Input-Errors 3 integer Acc
-ATTRIBUTE Acc-Output-Errors 4 integer Acc
-ATTRIBUTE Acc-Access-Partition 5 string Acc
-ATTRIBUTE Acc-Customer-Id 6 string Acc
-ATTRIBUTE Acc-Ip-Gateway-Pri 7 ipaddr Acc
-ATTRIBUTE Acc-Ip-Gateway-Sec 8 ipaddr Acc
-ATTRIBUTE Acc-Route-Policy 9 integer Acc
-ATTRIBUTE Acc-ML-MLX-Admin-State 10 integer Acc
-ATTRIBUTE Acc-ML-Call-Threshold 11 integer Acc
-ATTRIBUTE Acc-ML-Clear-Threshold 12 integer Acc
-ATTRIBUTE Acc-ML-Damping-Factor 13 integer Acc
-ATTRIBUTE Acc-Tunnel-Secret 14 string Acc
-ATTRIBUTE Acc-Clearing-Cause 15 integer Acc
-ATTRIBUTE Acc-Clearing-Location 16 integer Acc
-ATTRIBUTE Acc-Service-Profile 17 string Acc
-ATTRIBUTE Acc-Request-Type 18 integer Acc
-ATTRIBUTE Acc-Bridging-Support 19 integer Acc
-ATTRIBUTE Acc-Apsm-Oversubscribed 20 integer Acc
-ATTRIBUTE Acc-Acct-On-Off-Reason 21 integer Acc
-ATTRIBUTE Acc-Tunnel-Port 22 integer Acc
-ATTRIBUTE Acc-Dns-Server-Pri 23 ipaddr Acc
-ATTRIBUTE Acc-Dns-Server-Sec 24 ipaddr Acc
-ATTRIBUTE Acc-Nbns-Server-Pri 25 ipaddr Acc
-ATTRIBUTE Acc-Nbns-Server-Sec 26 ipaddr Acc
-ATTRIBUTE Acc-Dial-Port-Index 27 integer Acc
-ATTRIBUTE Acc-Ip-Compression 28 integer Acc
-ATTRIBUTE Acc-Ipx-Compression 29 integer Acc
-ATTRIBUTE Acc-Connect-Tx-Speed 30 integer Acc
-ATTRIBUTE Acc-Connect-Rx-Speed 31 integer Acc
-ATTRIBUTE Acc-Modem-Modulation-Type 32 string Acc
-ATTRIBUTE Acc-Modem-Error-Protocol 33 string Acc
-ATTRIBUTE Acc-Callback-Delay 34 integer Acc
-ATTRIBUTE Acc-Callback-Num-Valid 35 string Acc
-ATTRIBUTE Acc-Callback-Mode 36 integer Acc
-ATTRIBUTE Acc-Callback-CBCP-Type 37 integer Acc
-ATTRIBUTE Acc-Dialout-Auth-Mode 38 integer Acc
-ATTRIBUTE Acc-Dialout-Auth-Password 39 string Acc
-ATTRIBUTE Acc-Dialout-Auth-Username 40 string Acc
-ATTRIBUTE Acc-Access-Community 42 integer Acc
-ATTRIBUTE Acc-Vpsm-Reject-Cause 43 integer Acc
-ATTRIBUTE Acc-Ace-Token 44 string Acc
-ATTRIBUTE Acc-Ace-Token-Ttl 45 integer Acc
-ATTRIBUTE Acc-Ip-Pool-Name 46 string Acc
-ATTRIBUTE Acc-Igmp-Admin-State 47 integer Acc
-ATTRIBUTE Acc-Igmp-Version 48 integer Acc
-
-VALUE Acc-Reason-Code No-reason-No-Failure 0
-VALUE Acc-Reason-Code Resource-shortage 1
-VALUE Acc-Reason-Code Session-already-open 2
-VALUE Acc-Reason-Code Too-many-RADIUS-users 3
-VALUE Acc-Reason-Code No-authentification-server 4
-VALUE Acc-Reason-Code No-authentification-response 5
-VALUE Acc-Reason-Code No-accounting-server 6
-VALUE Acc-Reason-Code No-accounting-response 7
-VALUE Acc-Reason-Code Access-Denied 8
-VALUE Acc-Reason-Code Temporary-buffer-shortage 9
-VALUE Acc-Reason-Code Protocol-error 10
-VALUE Acc-Reason-Code Invalid-attribute 11
-VALUE Acc-Reason-Code Invalid-service-type 12
-VALUE Acc-Reason-Code Invalid-framed-protocol 13
-VALUE Acc-Reason-Code Invalid-attribute-value 14
-VALUE Acc-Reason-Code Invalid-user-information 15
-VALUE Acc-Reason-Code Invalid-IP-address 16
-VALUE Acc-Reason-Code Invalid-integer-syntax 17
-VALUE Acc-Reason-Code Invalid-NAS-port 18
-VALUE Acc-Reason-Code Requested-by-user 19
-VALUE Acc-Reason-Code Network-disconnect 20
-VALUE Acc-Reason-Code Service-interruption 21
-VALUE Acc-Reason-Code Physical-port-error 22
-VALUE Acc-Reason-Code Idle-timeout 23
-VALUE Acc-Reason-Code Session-timeout 24
-VALUE Acc-Reason-Code Administrative-reset 25
-VALUE Acc-Reason-Code NAS-reload-or-reset 26
-VALUE Acc-Reason-Code NAS-error 27
-VALUE Acc-Reason-Code NAS-request 28
-VALUE Acc-Reason-Code Undefined-reason-given 29
-VALUE Acc-Reason-Code Conflicting-attributes 30
-VALUE Acc-Reason-Code Port-limit-exceeded 31
-VALUE Acc-Reason-Code Facility-not-available 32
-VALUE Acc-Reason-Code Internal-config-error 33
-VALUE Acc-Reason-Code Bad-route-specification 34
-VALUE Acc-Reason-Code Access-Partition-bind-failure 35
-VALUE Acc-Reason-Code Security-violation 36
-VALUE Acc-Reason-Code Request-type-conflict 37
-VALUE Acc-Reason-Code Configuration-disallowed 38
-VALUE Acc-Reason-Code Missing-attribute 39
-VALUE Acc-Reason-Code Invalid-request 40
-VALUE Acc-Reason-Code Missing-parameter 41
-VALUE Acc-Reason-Code Invalid-parameter 42
-VALUE Acc-Reason-Code Call-cleared-with-cause 43
-VALUE Acc-Reason-Code Inopportune-config-request 44
-VALUE Acc-Reason-Code Invalid-config-parameter 45
-VALUE Acc-Reason-Code Missing-config-parameter 46
-VALUE Acc-Reason-Code Incompatible-service-profile 47
-VALUE Acc-Reason-Code Administrative-reset-2 48
-VALUE Acc-Reason-Code Administrative-reload 49
-VALUE Acc-Reason-Code Port-unneeded 50
-VALUE Acc-Reason-Code Port-preempted 51
-VALUE Acc-Reason-Code Port-suspended 52
-VALUE Acc-Reason-Code Service-unavailable 53
-VALUE Acc-Reason-Code Callback 54
-VALUE Acc-Reason-Code User-error 55
-VALUE Acc-Reason-Code Host-request 56
-
-VALUE Acc-Ccp-Option Disabled 1
-VALUE Acc-Ccp-Option Enabled 2
-
-VALUE Acc-Route-Policy Funnel 1
-VALUE Acc-Route-Policy Direct 2
-
-VALUE Acc-ML-MLX-Admin-State Enabled 1
-VALUE Acc-ML-MLX-Admin-State Disabled 2
-
-VALUE Acc-Clearing-Cause Cause-unspecified 0
-VALUE Acc-Clearing-Cause Unassigned-number 1
-VALUE Acc-Clearing-Cause No-route-to-transit-network 2
-VALUE Acc-Clearing-Cause No-route-to-destination 3
-VALUE Acc-Clearing-Cause Channel-unacceptable 6
-VALUE Acc-Clearing-Cause Call-awarded-being-delivered 7
-VALUE Acc-Clearing-Cause Normal-clearing 16
-VALUE Acc-Clearing-Cause User-busy 17
-VALUE Acc-Clearing-Cause No-user-responding 18
-VALUE Acc-Clearing-Cause User-alerted-no-answer 19
-VALUE Acc-Clearing-Cause Call-rejected 21
-VALUE Acc-Clearing-Cause Number-changed 22
-VALUE Acc-Clearing-Cause Non-selected-user-clearing 26
-VALUE Acc-Clearing-Cause Destination-out-of-order 27
-VALUE Acc-Clearing-Cause Invalid-or-incomplete-number 28
-VALUE Acc-Clearing-Cause Facility-rejected 29
-VALUE Acc-Clearing-Cause Response-to-status-inquiry 30
-VALUE Acc-Clearing-Cause Normal-unspecified-cause 31
-VALUE Acc-Clearing-Cause No-circuit-or-channel-available 34
-VALUE Acc-Clearing-Cause Network-out-of-order 38
-VALUE Acc-Clearing-Cause Temporary-failure 41
-VALUE Acc-Clearing-Cause Switching-equipment-congestion 42
-VALUE Acc-Clearing-Cause Access-information-discarded 43
-VALUE Acc-Clearing-Cause Circuit-or-channel-unavailable 44
-VALUE Acc-Clearing-Cause Circuit-or-channed-preempted 45
-VALUE Acc-Clearing-Cause Resources-unavailable 47
-VALUE Acc-Clearing-Cause Quality-of-service-unavailable 49
-VALUE Acc-Clearing-Cause Facility-not-subscribed 50
-VALUE Acc-Clearing-Cause Outgoing-calls-barred 52
-VALUE Acc-Clearing-Cause Incoming-calls-barred 54
-VALUE Acc-Clearing-Cause Bearer-capability-unauthorized 57
-VALUE Acc-Clearing-Cause Bearer-capability-not-available 58
-VALUE Acc-Clearing-Cause Service-not-available 63
-VALUE Acc-Clearing-Cause Bearer-capablity-not-implmented 65
-VALUE Acc-Clearing-Cause Channel-type-not-implemented 66
-VALUE Acc-Clearing-Cause Facility-not-implemented 69
-VALUE Acc-Clearing-Cause Restrcted-digtal-infrmtion-only 70
-VALUE Acc-Clearing-Cause Service-not-implemented 79
-VALUE Acc-Clearing-Cause Invalid-call-reference 81
-VALUE Acc-Clearing-Cause Identified-channel-doesnt-exist 82
-VALUE Acc-Clearing-Cause Call-identify-in-use 84
-VALUE Acc-Clearing-Cause No-call-suspended 85
-VALUE Acc-Clearing-Cause Suspended-call-cleared 86
-VALUE Acc-Clearing-Cause Incompatible-destination 88
-VALUE Acc-Clearing-Cause Invalid-transit-network-selctin 91
-VALUE Acc-Clearing-Cause Invalid-message 95
-VALUE Acc-Clearing-Cause Mandtory-infrmtion-elment-miss 96
-VALUE Acc-Clearing-Cause Message-not-implemented 97
-VALUE Acc-Clearing-Cause Inopportune-message 98
-VALUE Acc-Clearing-Cause Infrmtion-elemnt-not-implmented 99
-VALUE Acc-Clearing-Cause Invlid-infrmtion-element-contnt 100
-VALUE Acc-Clearing-Cause Message-incompatible-with-state 101
-VALUE Acc-Clearing-Cause Recovery-on-timer-expiration 102
-VALUE Acc-Clearing-Cause Mndtry-infrmtion-elmnt-lngt-err 103
-VALUE Acc-Clearing-Cause Protocol-error 111
-VALUE Acc-Clearing-Cause Interworking 127
-
-VALUE Acc-Clearing-Location Local-or-remote-user 0
-VALUE Acc-Clearing-Location Prvte-ntwork-serving-local-user 1
-VALUE Acc-Clearing-Location Pblic-ntwork-serving-local-user 2
-VALUE Acc-Clearing-Location Transit-network 3
-VALUE Acc-Clearing-Location Prvte-ntwork-serv-remote-user 4
-VALUE Acc-Clearing-Location Pblic-ntwork-serv-remote-user 5
-VALUE Acc-Clearing-Location International-network 6
-VALUE Acc-Clearing-Location Beyond-interworking-point 10
-
-VALUE Acc-Request-Type Ring-Indication 1
-VALUE Acc-Request-Type Dial-Request 2
-VALUE Acc-Request-Type User-Authentification 3
-VALUE Acc-Request-Type Tunnel-Authentification 4
-
-VALUE Acc-Bridging-Support Disabled 1
-VALUE Acc-Bridging-Support Enabled 2
-
-VALUE Acc-Apsm-Oversubscribed False 1
-VALUE Acc-Apsm-Oversubscribed True 2
-
-VALUE Acc-Acct-On-Off-Reason NAS-Reset 0
-VALUE Acc-Acct-On-Off-Reason NAS-Reload 1
-VALUE Acc-Acct-On-Off-Reason Configuration-Reset 2
-VALUE Acc-Acct-On-Off-Reason Configuration-Reload 3
-VALUE Acc-Acct-On-Off-Reason Enabled 4
-VALUE Acc-Acct-On-Off-Reason Disabled 5
-
-VALUE Acc-Ip-Compression Disabled 1
-VALUE Acc-Ip-Compression Enabled 2
-
-VALUE Acc-Ipx-Compression Disabled 1
-VALUE Acc-Ipx-Compression Enabled 2
-
-VALUE Acc-Callback-Mode User-Auth 0
-VALUE Acc-Callback-Mode User-Specified-E-164 3
-VALUE Acc-Callback-Mode CBCP-Callback 6
-VALUE Acc-Callback-Mode CLI-Callback 7
-
-VALUE Acc-Callback-CBCP-Type CBCP-None 1
-VALUE Acc-Callback-CBCP-Type CBCP-User-Specified 2
-VALUE Acc-Callback-CBCP-Type CBCP-Pre-Specified 3
-
-VALUE Acc-Dialout-Auth-Mode PAP 1
-VALUE Acc-Dialout-Auth-Mode CHAP 2
-VALUE Acc-Dialout-Auth-Mode CHAP-PAP 3
-VALUE Acc-Dialout-Auth-Mode NONE 4
-
-VALUE Acc-Access-Community PUBLIC 1
-VALUE Acc-Access-Community NETMAN 2
-
-# Acc-Vpsm-Reject-Cause values (available in access-reject packets only)
-VALUE Acc-Vpsm-Reject-Cause No-Access-Partition 1
-VALUE Acc-Vpsm-Reject-Cause Access-Partition-Disabled 2
-VALUE Acc-Vpsm-Reject-Cause Partition-Portlimit-Exceeded 3
-VALUE Acc-Vpsm-Reject-Cause License-Portlimit-Exceeded 4
-VALUE Acc-Vpsm-Reject-Cause Home-Server-Down 5
-VALUE Acc-Vpsm-Reject-Cause Rejected-By-Home-Server 6
-VALUE Acc-Vpsm-Reject-Cause NAS-Administratively-Disabled 7
-
-# Acc-Igmp-Admin-State values
-VALUE Acc-Igmp-Admin-State Enabled 1
-VALUE Acc-Igmp-Admin-State Disabled 2
-
-# Acc-Igmp-Version values
-VALUE Acc-Igmp-Version V1 1
-VALUE Acc-Igmp-Version V2 2
+BEGIN-VENDOR Acc
+
+ATTRIBUTE Acc-Reason-Code 1 integer
+ATTRIBUTE Acc-Ccp-Option 2 integer
+ATTRIBUTE Acc-Input-Errors 3 integer
+ATTRIBUTE Acc-Output-Errors 4 integer
+ATTRIBUTE Acc-Access-Partition 5 string
+ATTRIBUTE Acc-Customer-Id 6 string
+ATTRIBUTE Acc-Ip-Gateway-Pri 7 ipaddr
+ATTRIBUTE Acc-Ip-Gateway-Sec 8 ipaddr
+ATTRIBUTE Acc-Route-Policy 9 integer
+ATTRIBUTE Acc-ML-MLX-Admin-State 10 integer
+ATTRIBUTE Acc-ML-Call-Threshold 11 integer
+ATTRIBUTE Acc-ML-Clear-Threshold 12 integer
+ATTRIBUTE Acc-ML-Damping-Factor 13 integer
+ATTRIBUTE Acc-Tunnel-Secret 14 string
+ATTRIBUTE Acc-Clearing-Cause 15 integer
+ATTRIBUTE Acc-Clearing-Location 16 integer
+ATTRIBUTE Acc-Service-Profile 17 string
+ATTRIBUTE Acc-Request-Type 18 integer
+ATTRIBUTE Acc-Bridging-Support 19 integer
+ATTRIBUTE Acc-Apsm-Oversubscribed 20 integer
+ATTRIBUTE Acc-Acct-On-Off-Reason 21 integer
+ATTRIBUTE Acc-Tunnel-Port 22 integer
+ATTRIBUTE Acc-Dns-Server-Pri 23 ipaddr
+ATTRIBUTE Acc-Dns-Server-Sec 24 ipaddr
+ATTRIBUTE Acc-Nbns-Server-Pri 25 ipaddr
+ATTRIBUTE Acc-Nbns-Server-Sec 26 ipaddr
+ATTRIBUTE Acc-Dial-Port-Index 27 integer
+ATTRIBUTE Acc-Ip-Compression 28 integer
+ATTRIBUTE Acc-Ipx-Compression 29 integer
+ATTRIBUTE Acc-Connect-Tx-Speed 30 integer
+ATTRIBUTE Acc-Connect-Rx-Speed 31 integer
+ATTRIBUTE Acc-Modem-Modulation-Type 32 string
+ATTRIBUTE Acc-Modem-Error-Protocol 33 string
+ATTRIBUTE Acc-Callback-Delay 34 integer
+ATTRIBUTE Acc-Callback-Num-Valid 35 string
+ATTRIBUTE Acc-Callback-Mode 36 integer
+ATTRIBUTE Acc-Callback-CBCP-Type 37 integer
+ATTRIBUTE Acc-Dialout-Auth-Mode 38 integer
+ATTRIBUTE Acc-Dialout-Auth-Password 39 string
+ATTRIBUTE Acc-Dialout-Auth-Username 40 string
+ATTRIBUTE Acc-Access-Community 42 integer
+ATTRIBUTE Acc-Vpsm-Reject-Cause 43 integer
+ATTRIBUTE Acc-Ace-Token 44 string
+ATTRIBUTE Acc-Ace-Token-Ttl 45 integer
+ATTRIBUTE Acc-Ip-Pool-Name 46 string
+ATTRIBUTE Acc-Igmp-Admin-State 47 integer
+ATTRIBUTE Acc-Igmp-Version 48 integer
+ATTRIBUTE Acc-Location-Id 98 string
+ATTRIBUTE Acc-Calling-Station-Category 99 integer
+
+VALUE Acc-Reason-Code No-reason-No-Failure 0
+VALUE Acc-Reason-Code Resource-shortage 1
+VALUE Acc-Reason-Code Session-already-open 2
+VALUE Acc-Reason-Code Too-many-RADIUS-users 3
+VALUE Acc-Reason-Code No-authentification-server 4
+VALUE Acc-Reason-Code No-authentification-response 5
+VALUE Acc-Reason-Code No-accounting-server 6
+VALUE Acc-Reason-Code No-accounting-response 7
+VALUE Acc-Reason-Code Access-Denied 8
+VALUE Acc-Reason-Code Temporary-buffer-shortage 9
+VALUE Acc-Reason-Code Protocol-error 10
+VALUE Acc-Reason-Code Invalid-attribute 11
+VALUE Acc-Reason-Code Invalid-service-type 12
+VALUE Acc-Reason-Code Invalid-framed-protocol 13
+VALUE Acc-Reason-Code Invalid-attribute-value 14
+VALUE Acc-Reason-Code Invalid-user-information 15
+VALUE Acc-Reason-Code Invalid-IP-address 16
+VALUE Acc-Reason-Code Invalid-integer-syntax 17
+VALUE Acc-Reason-Code Invalid-NAS-port 18
+VALUE Acc-Reason-Code Requested-by-user 19
+VALUE Acc-Reason-Code Network-disconnect 20
+VALUE Acc-Reason-Code Service-interruption 21
+VALUE Acc-Reason-Code Physical-port-error 22
+VALUE Acc-Reason-Code Idle-timeout 23
+VALUE Acc-Reason-Code Session-timeout 24
+VALUE Acc-Reason-Code Administrative-reset 25
+VALUE Acc-Reason-Code NAS-reload-or-reset 26
+VALUE Acc-Reason-Code NAS-error 27
+VALUE Acc-Reason-Code NAS-request 28
+VALUE Acc-Reason-Code Undefined-reason-given 29
+VALUE Acc-Reason-Code Conflicting-attributes 30
+VALUE Acc-Reason-Code Port-limit-exceeded 31
+VALUE Acc-Reason-Code Facility-not-available 32
+VALUE Acc-Reason-Code Internal-config-error 33
+VALUE Acc-Reason-Code Bad-route-specification 34
+VALUE Acc-Reason-Code Access-Partition-bind-failure 35
+VALUE Acc-Reason-Code Security-violation 36
+VALUE Acc-Reason-Code Request-type-conflict 37
+VALUE Acc-Reason-Code Configuration-disallowed 38
+VALUE Acc-Reason-Code Missing-attribute 39
+VALUE Acc-Reason-Code Invalid-request 40
+VALUE Acc-Reason-Code Missing-parameter 41
+VALUE Acc-Reason-Code Invalid-parameter 42
+VALUE Acc-Reason-Code Call-cleared-with-cause 43
+VALUE Acc-Reason-Code Inopportune-config-request 44
+VALUE Acc-Reason-Code Invalid-config-parameter 45
+VALUE Acc-Reason-Code Missing-config-parameter 46
+VALUE Acc-Reason-Code Incompatible-service-profile 47
+VALUE Acc-Reason-Code Administrative-reset-2 48
+VALUE Acc-Reason-Code Administrative-reload 49
+VALUE Acc-Reason-Code Port-unneeded 50
+VALUE Acc-Reason-Code Port-preempted 51
+VALUE Acc-Reason-Code Port-suspended 52
+VALUE Acc-Reason-Code Service-unavailable 53
+VALUE Acc-Reason-Code Callback 54
+VALUE Acc-Reason-Code User-error 55
+VALUE Acc-Reason-Code Host-request 56
+
+VALUE Acc-Ccp-Option Disabled 1
+VALUE Acc-Ccp-Option Enabled 2
+
+VALUE Acc-Route-Policy Funnel 1
+VALUE Acc-Route-Policy Direct 2
+
+VALUE Acc-ML-MLX-Admin-State Enabled 1
+VALUE Acc-ML-MLX-Admin-State Disabled 2
+
+VALUE Acc-Clearing-Cause Cause-unspecified 0
+VALUE Acc-Clearing-Cause Unassigned-number 1
+VALUE Acc-Clearing-Cause No-route-to-transit-network 2
+VALUE Acc-Clearing-Cause No-route-to-destination 3
+VALUE Acc-Clearing-Cause Channel-unacceptable 6
+VALUE Acc-Clearing-Cause Call-awarded-being-delivered 7
+VALUE Acc-Clearing-Cause Normal-clearing 16
+VALUE Acc-Clearing-Cause User-busy 17
+VALUE Acc-Clearing-Cause No-user-responding 18
+VALUE Acc-Clearing-Cause User-alerted-no-answer 19
+VALUE Acc-Clearing-Cause Call-rejected 21
+VALUE Acc-Clearing-Cause Number-changed 22
+VALUE Acc-Clearing-Cause Non-selected-user-clearing 26
+VALUE Acc-Clearing-Cause Destination-out-of-order 27
+VALUE Acc-Clearing-Cause Invalid-or-incomplete-number 28
+VALUE Acc-Clearing-Cause Facility-rejected 29
+VALUE Acc-Clearing-Cause Response-to-status-inquiry 30
+VALUE Acc-Clearing-Cause Normal-unspecified-cause 31
+VALUE Acc-Clearing-Cause No-circuit-or-channel-available 34
+VALUE Acc-Clearing-Cause Network-out-of-order 38
+VALUE Acc-Clearing-Cause Temporary-failure 41
+VALUE Acc-Clearing-Cause Switching-equipment-congestion 42
+VALUE Acc-Clearing-Cause Access-information-discarded 43
+VALUE Acc-Clearing-Cause Circuit-or-channel-unavailable 44
+VALUE Acc-Clearing-Cause Circuit-or-channed-preempted 45
+VALUE Acc-Clearing-Cause Resources-unavailable 47
+VALUE Acc-Clearing-Cause Quality-of-service-unavailable 49
+VALUE Acc-Clearing-Cause Facility-not-subscribed 50
+VALUE Acc-Clearing-Cause Outgoing-calls-barred 52
+VALUE Acc-Clearing-Cause Incoming-calls-barred 54
+VALUE Acc-Clearing-Cause Bearer-capability-unauthorized 57
+VALUE Acc-Clearing-Cause Bearer-capability-not-available 58
+VALUE Acc-Clearing-Cause Service-not-available 63
+VALUE Acc-Clearing-Cause Bearer-capablity-not-implmented 65
+VALUE Acc-Clearing-Cause Channel-type-not-implemented 66
+VALUE Acc-Clearing-Cause Facility-not-implemented 69
+VALUE Acc-Clearing-Cause Restrcted-digtal-infrmtion-only 70
+VALUE Acc-Clearing-Cause Service-not-implemented 79
+VALUE Acc-Clearing-Cause Invalid-call-reference 81
+VALUE Acc-Clearing-Cause Identified-channel-doesnt-exist 82
+VALUE Acc-Clearing-Cause Call-identify-in-use 84
+VALUE Acc-Clearing-Cause No-call-suspended 85
+VALUE Acc-Clearing-Cause Suspended-call-cleared 86
+VALUE Acc-Clearing-Cause Incompatible-destination 88
+VALUE Acc-Clearing-Cause Invalid-transit-network-selctin 91
+VALUE Acc-Clearing-Cause Invalid-message 95
+VALUE Acc-Clearing-Cause Mandtory-infrmtion-elment-miss 96
+VALUE Acc-Clearing-Cause Message-not-implemented 97
+VALUE Acc-Clearing-Cause Inopportune-message 98
+VALUE Acc-Clearing-Cause Infrmtion-elemnt-not-implmented 99
+VALUE Acc-Clearing-Cause Invlid-infrmtion-element-contnt 100
+VALUE Acc-Clearing-Cause Message-incompatible-with-state 101
+VALUE Acc-Clearing-Cause Recovery-on-timer-expiration 102
+VALUE Acc-Clearing-Cause Mndtry-infrmtion-elmnt-lngt-err 103
+VALUE Acc-Clearing-Cause Protocol-error 111
+VALUE Acc-Clearing-Cause Interworking 127
+
+VALUE Acc-Clearing-Location Local-or-remote-user 0
+VALUE Acc-Clearing-Location Prvte-ntwork-serving-local-user 1
+VALUE Acc-Clearing-Location Pblic-ntwork-serving-local-user 2
+VALUE Acc-Clearing-Location Transit-network 3
+VALUE Acc-Clearing-Location Prvte-ntwork-serv-remote-user 4
+VALUE Acc-Clearing-Location Pblic-ntwork-serv-remote-user 5
+VALUE Acc-Clearing-Location International-network 6
+VALUE Acc-Clearing-Location Beyond-interworking-point 10
+
+VALUE Acc-Request-Type Ring-Indication 1
+VALUE Acc-Request-Type Dial-Request 2
+VALUE Acc-Request-Type User-Authentification 3
+VALUE Acc-Request-Type Tunnel-Authentification 4
+
+VALUE Acc-Bridging-Support Disabled 1
+VALUE Acc-Bridging-Support Enabled 2
+
+VALUE Acc-Apsm-Oversubscribed False 1
+VALUE Acc-Apsm-Oversubscribed True 2
+
+VALUE Acc-Acct-On-Off-Reason NAS-Reset 0
+VALUE Acc-Acct-On-Off-Reason NAS-Reload 1
+VALUE Acc-Acct-On-Off-Reason Configuration-Reset 2
+VALUE Acc-Acct-On-Off-Reason Configuration-Reload 3
+VALUE Acc-Acct-On-Off-Reason Enabled 4
+VALUE Acc-Acct-On-Off-Reason Disabled 5
+
+VALUE Acc-Ip-Compression Disabled 1
+VALUE Acc-Ip-Compression Enabled 2
+
+VALUE Acc-Ipx-Compression Disabled 1
+VALUE Acc-Ipx-Compression Enabled 2
+
+VALUE Acc-Callback-Mode User-Auth 0
+VALUE Acc-Callback-Mode User-Specified-E-164 3
+VALUE Acc-Callback-Mode CBCP-Callback 6
+VALUE Acc-Callback-Mode CLI-Callback 7
+
+VALUE Acc-Callback-CBCP-Type CBCP-None 1
+VALUE Acc-Callback-CBCP-Type CBCP-User-Specified 2
+VALUE Acc-Callback-CBCP-Type CBCP-Pre-Specified 3
+
+VALUE Acc-Dialout-Auth-Mode PAP 1
+VALUE Acc-Dialout-Auth-Mode CHAP 2
+VALUE Acc-Dialout-Auth-Mode CHAP-PAP 3
+VALUE Acc-Dialout-Auth-Mode NONE 4
+
+VALUE Acc-Access-Community PUBLIC 1
+VALUE Acc-Access-Community NETMAN 2
+
+# Acc-Vpsm-Reject-Cause values (available in access-reject packets only)
+VALUE Acc-Vpsm-Reject-Cause No-Access-Partition 1
+VALUE Acc-Vpsm-Reject-Cause Access-Partition-Disabled 2
+VALUE Acc-Vpsm-Reject-Cause Partition-Portlimit-Exceeded 3
+VALUE Acc-Vpsm-Reject-Cause License-Portlimit-Exceeded 4
+VALUE Acc-Vpsm-Reject-Cause Home-Server-Down 5
+VALUE Acc-Vpsm-Reject-Cause Rejected-By-Home-Server 6
+VALUE Acc-Vpsm-Reject-Cause NAS-Administratively-Disabled 7
+
+# Acc-Igmp-Admin-State values
+VALUE Acc-Igmp-Admin-State Enabled 1
+VALUE Acc-Igmp-Admin-State Disabled 2
+
+# Acc-Igmp-Version values
+VALUE Acc-Igmp-Version V1 1
+VALUE Acc-Igmp-Version V2 2
+
+END-VENDOR Acc
--- /dev/null
+# -*- text -*-
+#
+# As found on the net.
+#
+# $Id$
+#
+VENDOR Airespace 14179
+
+BEGIN-VENDOR Airespace
+ATTRIBUTE Airespace-Wlan-Id 1 integer
+ATTRIBUTE Airespace-QOS-Level 2 integer
+ATTRIBUTE Airespace-DSCP 3 integer
+ATTRIBUTE Airespace-8021p-Tag 4 integer
+ATTRIBUTE Airespace-Interface-Name 5 string
+ATTRIBUTE Airespace-ACL-Name 6 string
+
+VALUE Airespace-QOS-Level Bronze 0
+VALUE Airespace-QOS-Level Silver 1
+VALUE Airespace-QOS-Level Gold 2
+VALUE Airespace-QOS-Level Platinum 3
+VALUE Airespace-QOS-Level Uranium 4
+
+END-VENDOR Airespace
\ No newline at end of file
+# -*- text -*-
+##############################################################################
#
-# Alcatel Broadband Access Server dictionary.
+# Alcatel Broadband Access Server dictionary.
#
-# Version: 1.00 10-July-2002 Lasse Johnsen <lassejohnsen@bulldogcommunications.com>
-# $Id$
+# $Id$
#
+##############################################################################
-VENDOR Alcatel 3041
+VENDOR Alcatel 3041
-#
-# Alcatel Vendor Specific Extensions
-#
-#
-ATTRIBUTE AAT-Client-Primary-DNS 5 ipaddr Alcatel
-ATTRIBUTE AAT-Client-Primary-WINS-NBNS 6 ipaddr Alcatel
-ATTRIBUTE AAT-Client-Secondary-WINS-NBNS 7 ipaddr Alcatel
-#ATTRIBUTE AAT-Client-Primary-DNS 8 ipaddr Alcatel
-ATTRIBUTE AAT-PPP-Address 9 ipaddr Alcatel
-ATTRIBUTE AAT-ATM-Direct 21 string Alcatel
-ATTRIBUTE AAT-IP-TOS 22 integer Alcatel
-ATTRIBUTE AAT-IP-TOS-Precedence 23 integer Alcatel
-ATTRIBUTE AAT-IP-TOS-Apply-To 24 integer Alcatel
-ATTRIBUTE AAT-MCast-Client 27 integer Alcatel
-ATTRIBUTE AAT-Vrouter-Name 61 string Alcatel
-ATTRIBUTE AAT-Require-Auth 62 integer Alcatel
-ATTRIBUTE AAT-IP-Pool-Definition 63 string Alcatel
-ATTRIBUTE AAT-Assign-IP-Pool 64 integer Alcatel
-ATTRIBUTE AAT-Data-Filter 65 string Alcatel
-ATTRIBUTE AAT-Source-IP-Check 66 integer Alcatel
-ATTRIBUTE AAT-ATM-VPI 128 integer Alcatel
-ATTRIBUTE AAT-ATM-VCI 129 integer Alcatel
-ATTRIBUTE AAT-Input-Octets-Diff 130 integer Alcatel
-ATTRIBUTE AAT-Output-Octets-Diff 131 integer Alcatel
-ATTRIBUTE AAT-User-MAC-Address 132 string Alcatel
-ATTRIBUTE AAT-ATM-Traffic-Profile 133 string Alcatel
+BEGIN-VENDOR Alcatel
+
+ATTRIBUTE AAT-Client-Primary-DNS 5 ipaddr
+ATTRIBUTE AAT-Client-Primary-WINS-NBNS 6 ipaddr
+ATTRIBUTE AAT-Client-Secondary-WINS-NBNS 7 ipaddr
+ATTRIBUTE AAT-Client-Secondary-DNS 8 ipaddr
+ATTRIBUTE AAT-PPP-Address 9 ipaddr
+ATTRIBUTE AAT-PPP-Netmask 10 ipaddr
+ATTRIBUTE AAT-Primary-Home-Agent 12 string
+ATTRIBUTE AAT-Secondary-Home-Agent 13 string
+ATTRIBUTE AAT-Home-Agent-Password 14 string
+ATTRIBUTE AAT-Home-Network-Name 15 string
+ATTRIBUTE AAT-Home-Agent-UDP-Port 16 integer
+ATTRIBUTE AAT-IP-Direct 17 ipaddr
+ATTRIBUTE AAT-FR-Direct 18 integer
+ATTRIBUTE AAT-FR-Direct-Profile 19 string
+ATTRIBUTE AAT-FR-Direct-DLCI 20 integer
+ATTRIBUTE AAT-ATM-Direct 21 string
+ATTRIBUTE AAT-IP-TOS 22 integer
+ATTRIBUTE AAT-IP-TOS-Precedence 23 integer
+ATTRIBUTE AAT-IP-TOS-Apply-To 24 integer
+ATTRIBUTE AAT-MCast-Client 27 integer
+ATTRIBUTE AAT-Modem-Port-No 28 integer
+ATTRIBUTE AAT-Modem-Slot-No 29 integer
+ATTRIBUTE AAT-Modem-Shelf-No 30 integer
+ATTRIBUTE AAT-Filter 60 string
+ATTRIBUTE AAT-Vrouter-Name 61 string
+ATTRIBUTE AAT-Require-Auth 62 integer
+ATTRIBUTE AAT-IP-Pool-Definition 63 string
+ATTRIBUTE AAT-Assign-IP-Pool 64 integer
+ATTRIBUTE AAT-Data-Filter 65 string
+ATTRIBUTE AAT-Source-IP-Check 66 integer
+ATTRIBUTE AAT-Modem-Answer-String 67 string
+ATTRIBUTE AAT-Auth-Type 68 integer
+ATTRIBUTE AAT-Qos 70 integer
+ATTRIBUTE AAT-Qoa 71 integer
+ATTRIBUTE AAT-Client-Assign-DNS 72 integer
+ATTRIBUTE AAT-ATM-VPI 128 integer
+ATTRIBUTE AAT-ATM-VCI 129 integer
+ATTRIBUTE AAT-Input-Octets-Diff 130 integer
+ATTRIBUTE AAT-Output-Octets-Diff 131 integer
+ATTRIBUTE AAT-User-MAC-Address 132 string
+ATTRIBUTE AAT-ATM-Traffic-Profile 133 string
+
+VALUE AAT-MCast-Client Multicast-No 0
+VALUE AAT-MCast-Client Multicast-Yes 1
+
+VALUE AAT-Require-Auth Not-Require-Auth 0
+VALUE AAT-Require-Auth Require-Auth 1
+
+VALUE AAT-FR-Direct No 0
+VALUE AAT-FR-Direct Yes 1
+
+VALUE AAT-Source-IP-Check Source-IP-Check-No 0
+VALUE AAT-Source-IP-Check Source-IP-Check-Yes 1
-VALUE AAT-MCast-Client Multicast-No 0
-VALUE AAT-MCast-Client Multicast-Yes 1
+VALUE AAT-IP-TOS IP-TOS-Normal 0
+VALUE AAT-IP-TOS IP-TOS-Disabled 1
+VALUE AAT-IP-TOS IP-TOS-Cost 2
+VALUE AAT-IP-TOS IP-TOS-Reliability 4
+VALUE AAT-IP-TOS IP-TOS-Throughput 8
+VALUE AAT-IP-TOS IP-TOS-Latency 16
-VALUE AAT-Require-Auth Not-Require-Auth 0
-VALUE AAT-Require-Auth Require-Auth 1
+VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Incoming 1024
+VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Both 3072
+VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Outgoing 2048
-VALUE AAT-Source-IP-Check Source-IP-Check-No 0
-VALUE AAT-Source-IP-Check Source-IP-Check-Yes 1
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Normal 0
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-One 32
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Two 64
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Three 96
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Four 128
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Five 160
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Six 192
+VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Seven 224
-VALUE AAT-IP-TOS IP-TOS-Normal 0
-VALUE AAT-IP-TOS IP-TOS-Disabled 1
-VALUE AAT-IP-TOS IP-TOS-Cost 2
-VALUE AAT-IP-TOS IP-TOS-Reliability 4
-VALUE AAT-IP-TOS IP-TOS-Throughput 8
-VALUE AAT-IP-TOS IP-TOS-Latency 16
+VALUE AAT-Auth-Type AAT-Auth-None 0
+VALUE AAT-Auth-Type AAT-Auth-Default 1
+VALUE AAT-Auth-Type AAT-Auth-Any 2
+VALUE AAT-Auth-Type AAT-Auth-PAP 3
+VALUE AAT-Auth-Type AAT-Auth-CHAP 4
+VALUE AAT-Auth-Type AAT-Auth-MS-CHAP 5
-VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Incoming 1024
-VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Both 3072
-VALUE AAT-IP-TOS-Apply-To IP-TOS-Apply-To-Outgoing 2048
+VALUE AAT-Client-Assign-DNS DNS-Assign-No 0
+VALUE AAT-Client-Assign-DNS DNS-Assign-Yes 1
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Normal 0
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-One 32
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Two 64
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Three 96
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Four 128
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Five 160
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Six 192
-VALUE AAT-IP-TOS-Precedence IP-TOS-Precedence-Pri-Seven 224
+END-VENDOR Alcatel
+# -*- text -*-
#
# dictionary.alteon
#
#
# $Id$
#
-VENDOR Alteon 1872
+VENDOR Alteon 1872
-ATTRIBUTE Alteon-Service-Type 26 integer Alteon
+BEGIN-VENDOR Alteon
-VALUE Alteon-Service-Type Alteon-L4admin 250
-VALUE Alteon-Service-Type Alteon-Slbadmin 251
-VALUE Alteon-Service-Type Alteon-Oper 252
-VALUE Alteon-Service-Type Alteon-L4oper 253
-VALUE Alteon-Service-Type Alteon-Slboper 254
-VALUE Alteon-Service-Type Alteon-User 255
+ATTRIBUTE Alteon-Service-Type 26 integer
+
+VALUE Alteon-Service-Type Alteon-L4admin 250
+VALUE Alteon-Service-Type Alteon-Slbadmin 251
+VALUE Alteon-Service-Type Alteon-Oper 252
+VALUE Alteon-Service-Type Alteon-L4oper 253
+VALUE Alteon-Service-Type Alteon-Slboper 254
+VALUE Alteon-Service-Type Alteon-User 255
+
+END-VENDOR Alteon
+# -*- text -*-
# Altiga vendor attributes
#
# $Id$
#
-VENDOR Altiga 3076
-
-BEGIN-VENDOR Altiga
-ATTRIBUTE Altiga-Access-Hours-G/U 1 string
-ATTRIBUTE Altiga-Simultaneous-Logins-G/U 2 integer
-ATTRIBUTE Altiga-Min-Password-Length-G 3 integer
-ATTRIBUTE Altiga-Allow-Alpha-Only-Passwords-G 4 integer
-ATTRIBUTE Altiga-Primary-DNS-G 5 ipaddr
-ATTRIBUTE Altiga-Secondary-DNS-G 6 ipaddr
-ATTRIBUTE Altiga-Primary-WINS-G 7 ipaddr
-ATTRIBUTE Altiga-Secondary-WINS-G 8 ipaddr
-ATTRIBUTE Altiga-SEP-Card-Assignment-G/U 9 integer
-ATTRIBUTE Altiga-Priority-on-SEP-G/U 10 integer
+VENDOR Altiga 3076
+
+BEGIN-VENDOR Altiga
+ATTRIBUTE Altiga-Access-Hours-G/U 1 string
+ATTRIBUTE Altiga-Simultaneous-Logins-G/U 2 integer
+ATTRIBUTE Altiga-Min-Password-Length-G 3 integer
+ATTRIBUTE Altiga-Allow-Alpha-Only-Passwords-G 4 integer
+ATTRIBUTE Altiga-Primary-DNS-G 5 ipaddr
+ATTRIBUTE Altiga-Secondary-DNS-G 6 ipaddr
+ATTRIBUTE Altiga-Primary-WINS-G 7 ipaddr
+ATTRIBUTE Altiga-Secondary-WINS-G 8 ipaddr
+ATTRIBUTE Altiga-SEP-Card-Assignment-G/U 9 integer
+ATTRIBUTE Altiga-Priority-on-SEP-G/U 10 integer
ATTRIBUTE Altiga-Tunneling-Protocols-G/U 11 integer
-ATTRIBUTE Altiga-IPSec-Sec-Association-G/U 12 string
-ATTRIBUTE Altiga-IPSec-Authentication-G 13 integer
-ATTRIBUTE Altiga-IPSec-Banner-G 15 string
-ATTRIBUTE Altiga-IPSec-Allow-Passwd-Store-G/U 16 integer
-ATTRIBUTE Altiga-Use-Client-Address-G/U 17 integer
-ATTRIBUTE Altiga-PPTP-Min-Authentication-G/U 18 integer
-ATTRIBUTE Altiga-L2TP-Min-Authentication-G/U 19 integer
-ATTRIBUTE Altiga-PPTP-Encryption-G 20 integer
-ATTRIBUTE Altiga-L2TP-Encryption-G 21 integer
-ATTRIBUTE Altiga-IPSec-L2L-Keepalives-G 25 integer
-ATTRIBUTE Altiga-IPSec-Split-Tunnel-List-G 27 string
-ATTRIBUTE Altiga-IPSec-Default-Domain-G 28 string
-ATTRIBUTE Altiga-IPSec-Secondary-Domains-G 29 string
-ATTRIBUTE Altiga-IPSec-Tunnel-Type-G 30 integer
-ATTRIBUTE Altiga-IPSec-Mode-Config-G 31 integer
-ATTRIBUTE Altiga-IPSec-User-Group-Lock-G 33 integer
-ATTRIBUTE Altiga-IPSec-Over-NAT-G 34 integer
-ATTRIBUTE Altiga-IPSec-Over-NAT-Port-Num-G 35 integer
+ATTRIBUTE Altiga-IPSec-Sec-Association-G/U 12 string
+ATTRIBUTE Altiga-IPSec-Authentication-G 13 integer
+ATTRIBUTE Altiga-IPSec-Banner-G 15 string
+ATTRIBUTE Altiga-IPSec-Allow-Passwd-Store-G/U 16 integer
+ATTRIBUTE Altiga-Use-Client-Address-G/U 17 integer
+ATTRIBUTE Altiga-PPTP-Min-Authentication-G/U 18 integer
+ATTRIBUTE Altiga-L2TP-Min-Authentication-G/U 19 integer
+ATTRIBUTE Altiga-PPTP-Encryption-G 20 integer
+ATTRIBUTE Altiga-L2TP-Encryption-G 21 integer
+ATTRIBUTE Altiga-IPSec-L2L-Keepalives-G 25 integer
+ATTRIBUTE Altiga-IPSec-Split-Tunnel-List-G 27 string
+ATTRIBUTE Altiga-IPSec-Default-Domain-G 28 string
+ATTRIBUTE Altiga-IPSec-Secondary-Domains-G 29 string
+ATTRIBUTE Altiga-IPSec-Tunnel-Type-G 30 integer
+ATTRIBUTE Altiga-IPSec-Mode-Config-G 31 integer
+ATTRIBUTE Altiga-IPSec-User-Group-Lock-G 33 integer
+ATTRIBUTE Altiga-IPSec-Over-NAT-G 34 integer
+ATTRIBUTE Altiga-IPSec-Over-NAT-Port-Num-G 35 integer
# Altiga value
-VALUE Altiga-Allow-Alpha-Only-Passwords-G Allow 1
-VALUE Altiga-Allow-Alpha-Only-Passwords-G Disallow 0
+VALUE Altiga-Allow-Alpha-Only-Passwords-G Allow 1
+VALUE Altiga-Allow-Alpha-Only-Passwords-G Disallow 0
VALUE Altiga-SEP-Card-Assignment-G/U SEP1 1
VALUE Altiga-SEP-Card-Assignment-G/U SEP2 2
VALUE Altiga-Tunneling-Protocols-G/U PPTP-and-IPSec 5
VALUE Altiga-Tunneling-Protocols-G/U All 15
-VALUE Altiga-IPSec-Authentication-G None 0
-VALUE Altiga-IPSec-Authentication-G RADIUS 1
-VALUE Altiga-IPSec-Authentication-G LDAP 2
-VALUE Altiga-IPSec-Authentication-G NTDomain 3
-VALUE Altiga-IPSec-Authentication-G SDI 4
-VALUE Altiga-IPSec-Authentication-G Internal 5
+VALUE Altiga-IPSec-Authentication-G None 0
+VALUE Altiga-IPSec-Authentication-G RADIUS 1
+VALUE Altiga-IPSec-Authentication-G LDAP 2
+VALUE Altiga-IPSec-Authentication-G NTDomain 3
+VALUE Altiga-IPSec-Authentication-G SDI 4
+VALUE Altiga-IPSec-Authentication-G Internal 5
VALUE Altiga-IPSec-Allow-Passwd-Store-G/U Allow 1
VALUE Altiga-IPSec-Allow-Passwd-Store-G/U Disallow 0
VALUE Altiga-L2TP-Min-Authentication-G/U PAP 1
VALUE Altiga-L2TP-Min-Authentication-G/U CHAP 2
-VALUE Altiga-L2TP-Min-Authentication-G/U EAP-MD5 4
+VALUE Altiga-L2TP-Min-Authentication-G/U EAP-MD5 4
VALUE Altiga-L2TP-Min-Authentication-G/U EAP-GTC 8
VALUE Altiga-L2TP-Min-Authentication-G/U EAP-TLS 16
VALUE Altiga-L2TP-Min-Authentication-G/U MSCHAPv1 32
VALUE Altiga-L2TP-Min-Authentication-G/U MSCHAPv2 64
VALUE Altiga-L2TP-Min-Authentication-G/U Default 102
-VALUE Altiga-PPTP-Encryption-G 40bit 2
-VALUE Altiga-PPTP-Encryption-G 40-Encryption-Req 3
-VALUE Altiga-PPTP-Encryption-G 128 4
-VALUE Altiga-PPTP-Encryption-G 128-Encryption-Req 5
-VALUE Altiga-PPTP-Encryption-G 40-or-128 6
-VALUE Altiga-PPTP-Encryption-G 40-or-128-Encry-Req 7
-VALUE Altiga-PPTP-Encryption-G 40-Stateless-Req 10
-VALUE Altiga-PPTP-Encryption-G 40-Enc/Stateless-Req 11
-VALUE Altiga-PPTP-Encryption-G 128-Stateless-Req 12
-VALUE Altiga-PPTP-Encryption-G 128-Enc/Stateless-Req 13
-VALUE Altiga-PPTP-Encryption-G 40/128-Stateless-Req 14
-VALUE Altiga-PPTP-Encryption-G 40/128-Enc/Statls-Req 15
-
-VALUE Altiga-L2TP-Encryption-G 40bit 2
-VALUE Altiga-L2TP-Encryption-G 40-Encryption-Req 3
-VALUE Altiga-L2TP-Encryption-G 128 4
-VALUE Altiga-L2TP-Encryption-G 128-Encryption-Req 5
-VALUE Altiga-L2TP-Encryption-G 40-or-128 6
-VALUE Altiga-L2TP-Encryption-G 40-or-128-Encry-Req 7
-VALUE Altiga-L2TP-Encryption-G 40-Stateless-Req 10
-VALUE Altiga-L2TP-Encryption-G 40-Enc/Stateless-Req 11
-VALUE Altiga-L2TP-Encryption-G 128-Stateless-Req 12
-VALUE Altiga-L2TP-Encryption-G 128-Enc/Stateless-Req 13
-VALUE Altiga-L2TP-Encryption-G 40/128-Stateless-Req 14
-VALUE Altiga-L2TP-Encryption-G 40/128-Enc/Statls-Req 15
-
-VALUE Altiga-IPSec-L2L-Keepalives-G ON 1
-VALUE Altiga-IPSec-L2L-Keepalives-G OFF 0
-
-VALUE Altiga-IPSec-Tunnel-Type-G LAN-to-LAN 1
-VALUE Altiga-IPSec-Tunnel-Type-G Remote-Access 2
-
-VALUE Altiga-IPSec-Mode-Config-G ON 1
-VALUE Altiga-IPSec-Mode-Config-G OFF 0
-
-VALUE Altiga-IPSec-User-Group-Lock-G ON 1
-VALUE Altiga-IPSec-User-Group-Lock-G OFF 0
-
-VALUE Altiga-IPSec-Over-NAT-G ON 1
-VALUE Altiga-IPSec-Over-NAT-G OFF 0
+VALUE Altiga-PPTP-Encryption-G PPTP-40bit 2
+VALUE Altiga-PPTP-Encryption-G PPTP-40-Encryption-Req 3
+VALUE Altiga-PPTP-Encryption-G PPTP-128 4
+VALUE Altiga-PPTP-Encryption-G PPTP-128-Encryption-Req 5
+VALUE Altiga-PPTP-Encryption-G PPTP-40-or-128 6
+VALUE Altiga-PPTP-Encryption-G PPTP-40-or-128-Encry-Req 7
+VALUE Altiga-PPTP-Encryption-G PPTP-40-Stateless-Req 10
+VALUE Altiga-PPTP-Encryption-G PPTP-40-Enc/Stateless-Req 11
+VALUE Altiga-PPTP-Encryption-G PPTP-128-Stateless-Req 12
+VALUE Altiga-PPTP-Encryption-G PPTP-128-Enc/Stateless-Req 13
+VALUE Altiga-PPTP-Encryption-G PPTP-40/128-Stateless-Req 14
+VALUE Altiga-PPTP-Encryption-G PPTP-40/128-Enc/Statls-Req 15
+
+VALUE Altiga-L2TP-Encryption-G L2TP-40bit 2
+VALUE Altiga-L2TP-Encryption-G L2TP-40-Encryption-Req 3
+VALUE Altiga-L2TP-Encryption-G L2TP-128 4
+VALUE Altiga-L2TP-Encryption-G L2TP-128-Encryption-Req 5
+VALUE Altiga-L2TP-Encryption-G L2TP-40-or-128 6
+VALUE Altiga-L2TP-Encryption-G L2TP-40-or-128-Encry-Req 7
+VALUE Altiga-L2TP-Encryption-G L2TP-40-Stateless-Req 10
+VALUE Altiga-L2TP-Encryption-G L2TP-40-Enc/Stateless-Req 11
+VALUE Altiga-L2TP-Encryption-G L2TP-128-Stateless-Req 12
+VALUE Altiga-L2TP-Encryption-G L2TP-128-Enc/Stateless-Req 13
+VALUE Altiga-L2TP-Encryption-G L2TP-40/128-Stateless-Req 14
+VALUE Altiga-L2TP-Encryption-G L2TP-40/128-Enc/Statls-Req 15
+
+VALUE Altiga-IPSec-L2L-Keepalives-G ON 1
+VALUE Altiga-IPSec-L2L-Keepalives-G OFF 0
+
+VALUE Altiga-IPSec-Tunnel-Type-G LAN-to-LAN 1
+VALUE Altiga-IPSec-Tunnel-Type-G Remote-Access 2
+
+VALUE Altiga-IPSec-Mode-Config-G ON 1
+VALUE Altiga-IPSec-Mode-Config-G OFF 0
+
+VALUE Altiga-IPSec-User-Group-Lock-G ON 1
+VALUE Altiga-IPSec-User-Group-Lock-G OFF 0
+
+VALUE Altiga-IPSec-Over-NAT-G ON 1
+VALUE Altiga-IPSec-Over-NAT-G OFF 0
END-VENDOR Altiga
+# -*- text -*-
#
# $Id$
#
-VENDOR Aptis 2637
+VENDOR Aptis 2637
-BEGIN-VENDOR Aptis
-ATTRIBUTE CVX-Identification 1 string
-ATTRIBUTE CVX-VPOP-ID 2 integer
-ATTRIBUTE CVX-SS7-Session-ID-Type 3 integer
-ATTRIBUTE CVX-Radius-Redirect 4 integer
-ATTRIBUTE CVX-IPSVC-AZNLVL 5 integer
-ATTRIBUTE CVX-IPSVC-Mask 6 integer
-ATTRIBUTE CVX-Multilink-Match-Info 7 integer
-ATTRIBUTE CVX-Multilink-Group-Number 8 integer
-ATTRIBUTE CVX-PPP-Log-Mask 9 integer
+BEGIN-VENDOR Aptis
+ATTRIBUTE CVX-Identification 1 string
+ATTRIBUTE CVX-VPOP-ID 2 integer
+ATTRIBUTE CVX-SS7-Session-ID-Type 3 integer
+ATTRIBUTE CVX-Radius-Redirect 4 integer
+ATTRIBUTE CVX-IPSVC-AZNLVL 5 integer
+ATTRIBUTE CVX-IPSVC-Mask 6 integer
+ATTRIBUTE CVX-Multilink-Match-Info 7 integer
+ATTRIBUTE CVX-Multilink-Group-Number 8 integer
+ATTRIBUTE CVX-PPP-Log-Mask 9 integer
-ATTRIBUTE CVX-Modem-Begin-Modulation 10 string
-ATTRIBUTE CVX-Modem-End-Modulation 11 string
-ATTRIBUTE CVX-Modem-Error-Correction 12 string
-ATTRIBUTE CVX-Modem-Data-Compression 13 string
-ATTRIBUTE CVX-Modem-Tx-Packets 14 integer
-ATTRIBUTE CVX-Modem-ReTx-Packets 15 integer
-ATTRIBUTE CVX-Modem-SNR 16 integer
-ATTRIBUTE CVX-Modem-Local-Retrains 17 integer
-ATTRIBUTE CVX-Modem-Remote-Retrains 18 integer
-ATTRIBUTE CVX-Modem-Local-Rate-Negs 19 integer
-ATTRIBUTE CVX-Modem-Remote-Rate-Negs 20 integer
-ATTRIBUTE CVX-Modem-Begin-Recv-Line-Lvl 21 integer
-ATTRIBUTE CVX-Modem-End-Recv-Line-Lvl 22 integer
+ATTRIBUTE CVX-Modem-Begin-Modulation 10 string
+ATTRIBUTE CVX-Modem-End-Modulation 11 string
+ATTRIBUTE CVX-Modem-Error-Correction 12 string
+ATTRIBUTE CVX-Modem-Data-Compression 13 string
+ATTRIBUTE CVX-Modem-Tx-Packets 14 integer
+ATTRIBUTE CVX-Modem-ReTx-Packets 15 integer
+ATTRIBUTE CVX-Modem-SNR 16 integer
+ATTRIBUTE CVX-Modem-Local-Retrains 17 integer
+ATTRIBUTE CVX-Modem-Remote-Retrains 18 integer
+ATTRIBUTE CVX-Modem-Local-Rate-Negs 19 integer
+ATTRIBUTE CVX-Modem-Remote-Rate-Negs 20 integer
+ATTRIBUTE CVX-Modem-Begin-Recv-Line-Lvl 21 integer
+ATTRIBUTE CVX-Modem-End-Recv-Line-Lvl 22 integer
+ATTRIBUTE CVX-Terminate-Component 23 integer
+ATTRIBUTE CVX-Terminate-Cause 24 integer
+ATTRIBUTE CVX-Reject-Reason 25 integer
-ATTRIBUTE CVX-Primary-DNS 135 ipaddr
-ATTRIBUTE CVX-Secondary-DNS 136 ipaddr
-ATTRIBUTE CVX-Client-Assign-DNS 137 integer
-ATTRIBUTE CVX-Multicast-Rate-Limit 152 integer
-ATTRIBUTE CVX-Multicast-Client 155 integer
-ATTRIBUTE CVX-Disconnect-Cause 195 integer
-ATTRIBUTE CVX-Data-Rate 197 integer
-ATTRIBUTE CVX-PreSession-Time 198 integer
-ATTRIBUTE CVX-Assign-IP-Pool 218 integer
-ATTRIBUTE CVX-Maximum-Channels 235 integer
-ATTRIBUTE CVX-Data-Filter 242 string
-ATTRIBUTE CVX-Idle-Limit 244 integer
-ATTRIBUTE CVX-PPP-Address 253 ipaddr
-ATTRIBUTE CVX-Xmit-Rate 255 integer
+#
+# These are similar to the Ascend attributes
+#
+ATTRIBUTE CVX-Primary-DNS 135 ipaddr
+ATTRIBUTE CVX-Secondary-DNS 136 ipaddr
+ATTRIBUTE CVX-Client-Assign-DNS 137 integer
+ATTRIBUTE CVX-Multicast-Rate-Limit 152 integer
+ATTRIBUTE CVX-Multicast-Client 155 integer
+ATTRIBUTE CVX-Disconnect-Cause 195 integer
+ATTRIBUTE CVX-Data-Rate 197 integer
+ATTRIBUTE CVX-PreSession-Time 198 integer
+ATTRIBUTE CVX-Assign-IP-Pool 218 integer
+ATTRIBUTE CVX-Maximum-Channels 235 integer
+ATTRIBUTE CVX-Data-Filter 242 string
+ATTRIBUTE CVX-Idle-Limit 244 integer
+ATTRIBUTE CVX-PPP-Address 253 ipaddr
+ATTRIBUTE CVX-Xmit-Rate 255 integer
+
+#
+# Aptis VSAs may have either one-octet or four-octet <type>
+# fields. One-octet types always have a type less than or equal
+# to 127 (i.e. the upper bit is set to 0); four-octet types
+# always have the upper bit set to 1.
+#
+# The 4-byte ones *appear* to also have a length, unlike the USR
+# attributes, but there's no way of knowing for sure.
+#
+# http://samuel.labs.nic.at/at43/dictionary
+# says a number of these are "boolean", which means what, exactly?
+#
+# These are commented out until we figure out how to parse them.
+#
+#ATTRIBUTE CVX-VPOP-DSByteEnabled 0x84c80001 integer
+#ATTRIBUTE CVX-VPOP-DSByteValue 0x84c80002 integer
+#ATTRIBUTE CVX-PPP-EstablishTimeLimit 0x85210065 integer
+#ATTRIBUTE CVX-PPP-ConnectLimit 0x85210066 integer
+#ATTRIBUTE CVX-PPP-InactivityLimit 0x85210067 integer
+#ATTRIBUTE CVX-PPP-MonitorTxActivity 0x85210068 integer
+#ATTRIBUTE CVX-PPP-MonitorRxActivity 0x85210069 integer
+#ATTRIBUTE CVX-PPP-CountRIP 0x8521006a integer
+#ATTRIBUTE CVX-PPP-CountPings 0x8521006b integer
+#ATTRIBUTE CVX-PPP-CountIGMP 0x8521006c integer
+#ATTRIBUTE CVX-PPP-UseEchoes 0x852100c9 integer
+#ATTRIBUTE CVX-PPP-SendID 0x852100ca integer
+#ATTRIBUTE CVX-PPP-SendTimeRemaining 0x852100cb integer
+#ATTRIBUTE CVX-PPP-SendMRU 0x8521012d integer
+#ATTRIBUTE CVX-PPP-SendACCM 0x8521012e integer
+#ATTRIBUTE CVX-PPP-SendMagic 0x8521012f integer
+#ATTRIBUTE CVX-PPP-SendPFC 0x85210130 integer
+#ATTRIBUTE CVX-PPP-SendACFC 0x85210131 integer
+#ATTRIBUTE CVX-PPP-SendShortSeq 0x85210132 integer
+#ATTRIBUTE CVX-PPP-SendEndpointDisc 0x85210133 integer
+#ATTRIBUTE CVX-PPP-AllowMRU 0x85210137 integer
+#ATTRIBUTE CVX-PPP-AllowACCM 0x85210138 integer
+#ATTRIBUTE CVX-PPP-AllowMagic 0x85210139 integer
+#ATTRIBUTE CVX-PPP-AllowPFC 0x8521013a integer
+#ATTRIBUTE CVX-PPP-AllowACFC 0x8521013b integer
+#ATTRIBUTE CVX-PPP-AllowShortSeq 0x8521013c integer
+#ATTRIBUTE CVX-PPP-AllowEndpointDisc 0x8521013d integer
+#ATTRIBUTE CVX-PPP-LCPMaxConfigure 0x85210191 integer
+#ATTRIBUTE CVX-PPP-LCPRestartTimer 0x85210192 integer
+#ATTRIBUTE CVX-PPP-PassiveLCP 0x85210193 integer
+#ATTRIBUTE CVX-PPP-PassiveLCPTimeout 0x85210194 integer
+#ATTRIBUTE CVX-PPP-MinRemoteMRU 0x852101f5 integer
+#ATTRIBUTE CVX-PPP-MinLocalMRU 0x852101f6 integer
+#ATTRIBUTE CVX-PPP-DesiredLocalMRU 0x852101f7 integer
+#ATTRIBUTE CVX-PPP-TransmitACCM 0x852101f8 integer
+#ATTRIBUTE CVX-PPP-ReceiveACCM 0x852101f9 integer
+#ATTRIBUTE CVX-PPP-MinRemoteMRRU 0x852101fa integer
+#ATTRIBUTE CVX-PPP-DesiredRemoteMRRU 0x852101fb integer
+#ATTRIBUTE CVX-PPP-MinLocalMRRU 0x852101fc integer
+#ATTRIBUTE CVX-PPP-DesiredLocalMRRU 0x852101fd integer
+#ATTRIBUTE CVX-PPP-LCPEchoRetries 0x852101fe integer
+#ATTRIBUTE CVX-PPP-LCPEchoTimeout 0x852101ff integer
+#ATTRIBUTE CVX-PPP-LCPEchoErrorTimeout 0x85210200 integer
+#ATTRIBUTE CVX-PPP-TimeRemainingInterval 0x85210201 integer
+#ATTRIBUTE CVX-PPP-IDText 0x85210202 string
+#ATTRIBUTE CVX-PPP-AuthRequire 0x85210259 integer
+#ATTRIBUTE CVX-PPP-AuthAllow 0x8521025a integer
+#ATTRIBUTE CVX-PPP-AuthServerProtocol1 0x85210262 integer
+#ATTRIBUTE CVX-PPP-AuthServerProtocol2 0x85210263 integer
+#ATTRIBUTE CVX-PPP-AuthServerProtocol3 0x85210264 integer
+#ATTRIBUTE CVX-PPP-AuthServerProtocol4 0x85210265 integer
+#ATTRIBUTE CVX-PPP-AuthClientProtocol1 0x8521026d integer
+#ATTRIBUTE CVX-PPP-AuthClientProtocol2 0x8521026e integer
+#ATTRIBUTE CVX-PPP-AuthClientProtocol3 0x8521026f integer
+#ATTRIBUTE CVX-PPP-AuthClientProtocol4 0x85210270 integer
+#ATTRIBUTE CVX-PPP-PAPClientRetries 0x85210277 integer
+#ATTRIBUTE CVX-PPP-PAPClientTimeout 0x85210278 integer
+#ATTRIBUTE CVX-PPP-PAPServerRetries 0x85210279 integer
+#ATTRIBUTE CVX-PPP-PAPServerTimeout 0x8521027a integer
+#ATTRIBUTE CVX-PPP-CHAPClientRetries 0x85210281 integer
+#ATTRIBUTE CVX-PPP-CHAPClientTimeout 0x85210282 integer
+#ATTRIBUTE CVX-PPP-CHAPServerRetries 0x85210283 integer
+#ATTRIBUTE CVX-PPP-CHAPServerChallenges 0x85210284 integer
+#ATTRIBUTE CVX-PPP-CHAPServerTimeout 0x85210285 integer
+#ATTRIBUTE CVX-PPP-CHAPValueLength 0x85210286 integer
+#ATTRIBUTE CVX-PPP-AuthFailureRenegotiatesLCP 0x85210287 integer
+#ATTRIBUTE CVX-PPP-UserName 0x8521028b string
+#ATTRIBUTE CVX-PPP-Password 0x8521028c string
+#ATTRIBUTE CVX-PPP-IPCPEnabled 0x852102bd integer
+#ATTRIBUTE CVX-PPP-LocalIPAddress 0x852102be ipaddr
+#ATTRIBUTE CVX-PPP-RemoteIPAddress 0x852102bf ipaddr
+#ATTRIBUTE CVX-PPP-AllowPeerIPAddress 0x852102c0 integer
+#ATTRIBUTE CVX-PPP-VJEnabled 0x852102c1 integer
+#ATTRIBUTE CVX-PPP-VJSlots 0x852102c2 integer
+#ATTRIBUTE CVX-PPP-SendDNS 0x852102c3 integer
+#ATTRIBUTE CVX-PPP-SendNBNS 0x852102c4 integer
+#ATTRIBUTE CVX-PPP-IPCPMaxConfigure 0x852102c5 integer
+#ATTRIBUTE CVX-PPP-IPCPRestartTimer 0x852102c6 integer
+#ATTRIBUTE CVX-PPP-PassiveIPCP 0x852102c7 integer
+#ATTRIBUTE CVX-PPP-PassiveIPCPTimeout 0x852102c8 integer
+#ATTRIBUTE CVX-PPP-DNS1 0x852102c9 ipaddr
+#ATTRIBUTE CVX-PPP-DNS2 0x852102ca ipaddr
+#ATTRIBUTE CVX-PPP-NBNS1 0x852102cb ipaddr
+#ATTRIBUTE CVX-PPP-NBNS2 0x852102cc ipaddr
+#ATTRIBUTE CVX-PPP-SendLocalIPAddress 0x852102cd integer
+#ATTRIBUTE CVX-PPP-RejectUnknownNS 0x852102ce integer
+#ATTRIBUTE CVX-PPP-PeerNSStrategy 0x852102cf integer
+#ATTRIBUTE CVX-PPP-MLPEnabled 0x85210321 integer
+#ATTRIBUTE CVX-PPP-MLPMaxLinks 0x85210322 integer
+#ATTRIBUTE CVX-PPP-MLPFragmentSize 0x85210323 integer
+#ATTRIBUTE CVX-PPP-MLPMaxFragments 0x85210324 integer
+#ATTRIBUTE CVX-PPP-MLPScaleFragments 0x85210325 integer
+#ATTRIBUTE CVX-PPP-MLPSendNullFragments 0x85210326 integer
+#ATTRIBUTE CVX-PPP-MLPNullFragmentTimeout 0x85210327 integer
+#ATTRIBUTE CVX-PPP-MLPEndpointDisc 0x85210328 integer
+#ATTRIBUTE CVX-PPP-MLPGroupNumber 0x85210329 integer
+#ATTRIBUTE CVX-PPP-LogEnabled 0x85210385 integer
+#ATTRIBUTE CVX-PPP-LogDump 0x85210386 integer
+#ATTRIBUTE CVX-PPP-LogSize 0x8521038e integer
+#ATTRIBUTE CVX-PPP-LogControlFrames 0x8521038f integer
+#ATTRIBUTE CVX-PPP-LogProtocolFrames 0x85210390 integer
+#ATTRIBUTE CVX-PPP-LogOptions 0x85210391 integer
+#ATTRIBUTE CVX-PPP-LogStates 0x85210392 integer
+#ATTRIBUTE CVX-PPP-LogCompression 0x85210393 integer
+#ATTRIBUTE CVX-PPP-LogMLP 0x85210394 integer
+#ATTRIBUTE CVX-PPP-LogVJ 0x85210395 integer
+#ATTRIBUTE CVX-PPP-CCPEnabled 0x852103e9 integer
+#ATTRIBUTE CVX-PPP-CompressFrames 0x852103ea integer
+#ATTRIBUTE CVX-PPP-Stac3Enabled 0x852103eb integer
+#ATTRIBUTE CVX-PPP-Stac4Enabled 0x852103ec integer
+#ATTRIBUTE CVX-PPP-MPPCEnabled 0x852103ed integer
+#ATTRIBUTE CVX-PPP-StacPerformance 0x852103ee integer
+#ATTRIBUTE CVX-PPP-StacMode 0x852103ef integer
END-VENDOR Aptis
--- /dev/null
+# -*- text -*-
+#
+# As posted to the list.
+#
+# Version: $Id$
+#
+VENDOR Aruba 14823
+BEGIN-VENDOR Aruba
+
+ATTRIBUTE Aruba-User-Role 1 string
+ATTRIBUTE Aruba-User-Vlan 2 integer
+ATTRIBUTE Aruba-Priv-Admin-User 3 integer
+ATTRIBUTE Aruba-Admin-Role 4 string
+ATTRIBUTE Aruba-Essid-Name 5 string
+ATTRIBUTE Aruba-Location-Id 6 string
+
+END-VENDOR Aruba
+# -*- text -*-
#
# Ascend dictionary.
# $Id$
# IP FILTERS:
#
# ip dir action [ dstip n.n.n.n/nn ] [ srcip n.n.n.n/nn ]
-# [ proto [ dstport cmp value ] [ srcport cmd value ] [ est ] ]
+# [ proto [ dstport cmp value ] [ srcport cmd value ] [ est ] ]
#
# Fields in [...] are optional.
# where:
# action: Filter action. "FORWARD" or "DROP"
#
# dstip: Keyword for destination IP address.
-# n.n.n.n = IP address. /nn - netmask.
-#
+# n.n.n.n = IP address. /nn - netmask.
+#
# srcip: Keyword for source IP address.
-# n.n.n.n = IP address. /nn - netmask.
-#
+# n.n.n.n = IP address. /nn - netmask.
+#
# proto: Optional protocol field. Either a name or
# number. Known names are in FilterProtoName[].
-#
+#
# dstport: Keyword for destination port. Only valid with tcp
# or udp. 'cmp' are in FilterPortType[]. 'value' can be
# a name or number.
# srcport: Keyword for source port. Only valid with tcp
# or udp. 'cmp' are in FilterPortType[]. 'value' can be
# a name or number.
-#
+#
# est: Keyword for TCP established. Valid only for tcp.
#
# IPX FILTERS
# cmd: One of ">" or "<" or "=" or "!=".
# (without the quotes)
#
-# value: Socket value to be compared against, in hex.
-#
+# value: Socket value to be compared against, in hex.
+#
# dstipxnet: Keyword for destination IPX address.
-# nnnn = IPX Node address.
-#
+# nnnn = IPX Node address.
+#
# dstipxnode: Keyword for destination IPX Node address.
# mmmmm = IPX Node Address, could be FFFFFF.
# A vlid ipx node number should accompany ipx net number.
-#
+#
# dstipxsoc: Keyword for destination IPX socket address.
-#
+#
# cmd: One of ">" or "<" or "=" or "!=".
# (without the quotes)
-#
+#
# value: Socket value to be compared against, in hex.
#
# GENERIC FILTERS
#
# action: Filter action. "FORWARD" or "DROP"
#
-# offset: A Number. Specifies an offset into a frame
+# offset: A Number. Specifies an offset into a frame
# to start comparing.
-#
+#
# mask: A hexadecimal mask of bits to compare.
-#
+#
# value: A value to compare with the masked data.
#
# compNeq: Defines type of comparison. ( "==" or "!=")
# Default is "==".
-#
+#
# more: Optional keyword MORE, to represent the attachment
# to the next entry.
-VENDOR Ascend 529
+VENDOR Ascend 529
+
+#
+# Ascend vendor-specific attributes.
+#
+BEGIN-VENDOR Ascend
+ATTRIBUTE Ascend-Max-Shared-Users 2 integer
+ATTRIBUTE Ascend-UU-Info 7 string
+ATTRIBUTE Ascend-CIR-Timer 9 integer
+ATTRIBUTE Ascend-FR-08-Mode 10 integer
+ATTRIBUTE Ascend-Destination-Nas-Port 11 integer
+ATTRIBUTE Ascend-FR-SVC-Addr 12 string
+ATTRIBUTE Ascend-NAS-Port-Format 13 integer
+ATTRIBUTE Ascend-ATM-Fault-Management 14 integer
+ATTRIBUTE Ascend-ATM-Loopback-Cell-Loss 15 integer
+ATTRIBUTE Ascend-Ckt-Type 16 integer
+ATTRIBUTE Ascend-SVC-Enabled 17 integer
+ATTRIBUTE Ascend-Session-Type 18 integer
+ATTRIBUTE Ascend-H323-Gatekeeper 19 ipaddr
+ATTRIBUTE Ascend-Global-Call-Id 20 string
+ATTRIBUTE Ascend-H323-Conference-Id 21 integer
+ATTRIBUTE Ascend-H323-Fegw-Address 22 ipaddr
+ATTRIBUTE Ascend-H323-Dialed-Time 23 integer
+ATTRIBUTE Ascend-Dialed-Number 24 string
+ATTRIBUTE Ascend-Inter-Arrival-Jitter 25 integer
+ATTRIBUTE Ascend-Dropped-Octets 26 integer
+ATTRIBUTE Ascend-Dropped-Packets 27 integer
+ATTRIBUTE Ascend-Auth-Delay 28 integer
+ATTRIBUTE Ascend-X25-Pad-X3-Profile 29 integer
+ATTRIBUTE Ascend-X25-Pad-X3-Parameters 30 string
+ATTRIBUTE Ascend-Tunnel-VRouter-Name 31 string
+ATTRIBUTE Ascend-X25-Reverse-Charging 32 integer
+ATTRIBUTE Ascend-X25-Nui-Prompt 33 string
+ATTRIBUTE Ascend-X25-Nui-Password-Prompt 34 string
+ATTRIBUTE Ascend-X25-Cug 35 string
+ATTRIBUTE Ascend-X25-Pad-Alias-1 36 string
+ATTRIBUTE Ascend-X25-Pad-Alias-2 37 string
+ATTRIBUTE Ascend-X25-Pad-Alias-3 38 string
+ATTRIBUTE Ascend-X25-X121-Address 39 string
+ATTRIBUTE Ascend-X25-Nui 40 string
+ATTRIBUTE Ascend-X25-Rpoa 41 string
+ATTRIBUTE Ascend-X25-Pad-Prompt 42 string
+ATTRIBUTE Ascend-X25-Pad-Banner 43 string
+ATTRIBUTE Ascend-X25-Profile-Name 44 string
+ATTRIBUTE Ascend-Recv-Name 45 string
+ATTRIBUTE Ascend-Bi-Directional-Auth 46 integer
+ATTRIBUTE Ascend-MTU 47 integer
+ATTRIBUTE Ascend-Call-Direction 48 integer
+ATTRIBUTE Ascend-Service-Type 49 integer
+ATTRIBUTE Ascend-Filter-Required 50 integer
+ATTRIBUTE Ascend-Traffic-Shaper 51 integer
+ATTRIBUTE Ascend-Access-Intercept-LEA 52 string
+ATTRIBUTE Ascend-Access-Intercept-Log 53 string
+ATTRIBUTE Ascend-Private-Route-Table-ID 54 string
+ATTRIBUTE Ascend-Private-Route-Required 55 integer
+ATTRIBUTE Ascend-Cache-Refresh 56 integer
+ATTRIBUTE Ascend-Cache-Time 57 integer
+ATTRIBUTE Ascend-Egress-Enabled 58 integer
+ATTRIBUTE Ascend-QOS-Upstream 59 string
+ATTRIBUTE Ascend-QOS-Downstream 60 string
+ATTRIBUTE Ascend-ATM-Connect-Vpi 61 integer
+ATTRIBUTE Ascend-ATM-Connect-Vci 62 integer
+ATTRIBUTE Ascend-ATM-Connect-Group 63 integer
+ATTRIBUTE Ascend-ATM-Group 64 integer
+ATTRIBUTE Ascend-IPX-Header-Compression 65 integer
+ATTRIBUTE Ascend-Calling-Id-Type-Of-Num 66 integer
+ATTRIBUTE Ascend-Calling-Id-Number-Plan 67 integer
+ATTRIBUTE Ascend-Calling-Id-Presentatn 68 integer
+ATTRIBUTE Ascend-Calling-Id-Screening 69 integer
+ATTRIBUTE Ascend-BIR-Enable 70 integer
+ATTRIBUTE Ascend-BIR-Proxy 71 integer
+ATTRIBUTE Ascend-BIR-Bridge-Group 72 integer
+ATTRIBUTE Ascend-IPSEC-Profile 73 string
+ATTRIBUTE Ascend-PPPoE-Enable 74 integer
+ATTRIBUTE Ascend-Bridge-Non-PPPoE 75 integer
+ATTRIBUTE Ascend-ATM-Direct 76 integer
+ATTRIBUTE Ascend-ATM-Direct-Profile 77 string
+ATTRIBUTE Ascend-Client-Primary-WINS 78 ipaddr
+ATTRIBUTE Ascend-Client-Secondary-WINS 79 ipaddr
+ATTRIBUTE Ascend-Client-Assign-WINS 80 integer
+ATTRIBUTE Ascend-Auth-Type 81 integer
+ATTRIBUTE Ascend-Port-Redir-Protocol 82 integer
+ATTRIBUTE Ascend-Port-Redir-Portnum 83 integer
+ATTRIBUTE Ascend-Port-Redir-Server 84 ipaddr
+ATTRIBUTE Ascend-IP-Pool-Chaining 85 integer
+ATTRIBUTE Ascend-Owner-IP-Addr 86 ipaddr
+ATTRIBUTE Ascend-IP-TOS 87 integer
+ATTRIBUTE Ascend-IP-TOS-Precedence 88 integer
+ATTRIBUTE Ascend-IP-TOS-Apply-To 89 integer
+ATTRIBUTE Ascend-Filter 90 string
+ATTRIBUTE Ascend-Telnet-Profile 91 string
+ATTRIBUTE Ascend-Dsl-Rate-Type 92 integer
+ATTRIBUTE Ascend-Redirect-Number 93 string
+ATTRIBUTE Ascend-ATM-Vpi 94 integer
+ATTRIBUTE Ascend-ATM-Vci 95 integer
+ATTRIBUTE Ascend-Source-IP-Check 96 integer
+ATTRIBUTE Ascend-Dsl-Rate-Mode 97 integer
+ATTRIBUTE Ascend-Dsl-Upstream-Limit 98 integer
+ATTRIBUTE Ascend-Dsl-Downstream-Limit 99 integer
+ATTRIBUTE Ascend-Dsl-CIR-Recv-Limit 100 integer
+ATTRIBUTE Ascend-Dsl-CIR-Xmit-Limit 101 integer
+ATTRIBUTE Ascend-VRouter-Name 102 string
+ATTRIBUTE Ascend-Source-Auth 103 string
+ATTRIBUTE Ascend-Private-Route 104 string
+ATTRIBUTE Ascend-Numbering-Plan-ID 105 integer
+ATTRIBUTE Ascend-FR-Link-Status-DLCI 106 integer
+ATTRIBUTE Ascend-Calling-Subaddress 107 string
+ATTRIBUTE Ascend-Callback-Delay 108 integer
+ATTRIBUTE Ascend-Endpoint-Disc 109 string
+ATTRIBUTE Ascend-Remote-FW 110 string
+ATTRIBUTE Ascend-Multicast-GLeave-Delay 111 integer
+ATTRIBUTE Ascend-CBCP-Enable 112 integer
+ATTRIBUTE Ascend-CBCP-Mode 113 integer
+ATTRIBUTE Ascend-CBCP-Delay 114 integer
+ATTRIBUTE Ascend-CBCP-Trunk-Group 115 integer
+ATTRIBUTE Ascend-Appletalk-Route 116 string
+ATTRIBUTE Ascend-Appletalk-Peer-Mode 117 integer
+ATTRIBUTE Ascend-Route-Appletalk 118 integer
+ATTRIBUTE Ascend-FCP-Parameter 119 string
+ATTRIBUTE Ascend-Modem-PortNo 120 integer
+ATTRIBUTE Ascend-Modem-SlotNo 121 integer
+ATTRIBUTE Ascend-Modem-ShelfNo 122 integer
+ATTRIBUTE Ascend-Call-Attempt-Limit 123 integer
+ATTRIBUTE Ascend-Call-Block-Duration 124 integer
+ATTRIBUTE Ascend-Maximum-Call-Duration 125 integer
+ATTRIBUTE Ascend-Temporary-Rtes 126 integer
+ATTRIBUTE Ascend-Tunneling-Protocol 127 integer
+ATTRIBUTE Ascend-Shared-Profile-Enable 128 integer
+ATTRIBUTE Ascend-Primary-Home-Agent 129 string
+ATTRIBUTE Ascend-Secondary-Home-Agent 130 string
+ATTRIBUTE Ascend-Dialout-Allowed 131 integer
+ATTRIBUTE Ascend-Client-Gateway 132 ipaddr
+ATTRIBUTE Ascend-BACP-Enable 133 integer
+ATTRIBUTE Ascend-DHCP-Maximum-Leases 134 integer
+ATTRIBUTE Ascend-Client-Primary-DNS 135 ipaddr
+ATTRIBUTE Ascend-Client-Secondary-DNS 136 ipaddr
+ATTRIBUTE Ascend-Client-Assign-DNS 137 integer
+ATTRIBUTE Ascend-User-Acct-Type 138 integer
+ATTRIBUTE Ascend-User-Acct-Host 139 ipaddr
+ATTRIBUTE Ascend-User-Acct-Port 140 integer
+ATTRIBUTE Ascend-User-Acct-Key 141 string
+ATTRIBUTE Ascend-User-Acct-Base 142 integer
+ATTRIBUTE Ascend-User-Acct-Time 143 integer
+ATTRIBUTE Ascend-Assign-IP-Client 144 ipaddr
+ATTRIBUTE Ascend-Assign-IP-Server 145 ipaddr
+ATTRIBUTE Ascend-Assign-IP-Global-Pool 146 string
+ATTRIBUTE Ascend-DHCP-Reply 147 integer
+ATTRIBUTE Ascend-DHCP-Pool-Number 148 integer
+ATTRIBUTE Ascend-Expect-Callback 149 integer
+ATTRIBUTE Ascend-Event-Type 150 integer
+ATTRIBUTE Ascend-Session-Svr-Key 151 string
+ATTRIBUTE Ascend-Multicast-Rate-Limit 152 integer
+ATTRIBUTE Ascend-IF-Netmask 153 ipaddr
+ATTRIBUTE Ascend-Remote-Addr 154 ipaddr
+ATTRIBUTE Ascend-Multicast-Client 155 integer
+ATTRIBUTE Ascend-FR-Circuit-Name 156 string
+ATTRIBUTE Ascend-FR-LinkUp 157 integer
+ATTRIBUTE Ascend-FR-Nailed-Grp 158 integer
+ATTRIBUTE Ascend-FR-Type 159 integer
+ATTRIBUTE Ascend-FR-Link-Mgt 160 integer
+ATTRIBUTE Ascend-FR-N391 161 integer
+ATTRIBUTE Ascend-FR-DCE-N392 162 integer
+ATTRIBUTE Ascend-FR-DTE-N392 163 integer
+ATTRIBUTE Ascend-FR-DCE-N393 164 integer
+ATTRIBUTE Ascend-FR-DTE-N393 165 integer
+ATTRIBUTE Ascend-FR-T391 166 integer
+ATTRIBUTE Ascend-FR-T392 167 integer
+ATTRIBUTE Ascend-Bridge-Address 168 string
+ATTRIBUTE Ascend-TS-Idle-Limit 169 integer
+ATTRIBUTE Ascend-TS-Idle-Mode 170 integer
+ATTRIBUTE Ascend-DBA-Monitor 171 integer
+ATTRIBUTE Ascend-Base-Channel-Count 172 integer
+ATTRIBUTE Ascend-Minimum-Channels 173 integer
+ATTRIBUTE Ascend-IPX-Route 174 string
+ATTRIBUTE Ascend-FT1-Caller 175 integer
+ATTRIBUTE Ascend-Backup 176 string
+ATTRIBUTE Ascend-Call-Type 177 integer
+ATTRIBUTE Ascend-Group 178 string
+ATTRIBUTE Ascend-FR-DLCI 179 integer
+ATTRIBUTE Ascend-FR-Profile-Name 180 string
+ATTRIBUTE Ascend-Ara-PW 181 string
+ATTRIBUTE Ascend-IPX-Node-Addr 182 string
+ATTRIBUTE Ascend-Home-Agent-IP-Addr 183 ipaddr
+ATTRIBUTE Ascend-Home-Agent-Password 184 string
+ATTRIBUTE Ascend-Home-Network-Name 185 string
+ATTRIBUTE Ascend-Home-Agent-UDP-Port 186 integer
+ATTRIBUTE Ascend-Multilink-ID 187 integer
+ATTRIBUTE Ascend-Num-In-Multilink 188 integer
+ATTRIBUTE Ascend-First-Dest 189 ipaddr
+ATTRIBUTE Ascend-Pre-Input-Octets 190 integer
+ATTRIBUTE Ascend-Pre-Output-Octets 191 integer
+ATTRIBUTE Ascend-Pre-Input-Packets 192 integer
+ATTRIBUTE Ascend-Pre-Output-Packets 193 integer
+ATTRIBUTE Ascend-Maximum-Time 194 integer
+ATTRIBUTE Ascend-Disconnect-Cause 195 integer
+ATTRIBUTE Ascend-Connect-Progress 196 integer
+ATTRIBUTE Ascend-Data-Rate 197 integer
+ATTRIBUTE Ascend-PreSession-Time 198 integer
+ATTRIBUTE Ascend-Token-Idle 199 integer
+ATTRIBUTE Ascend-Token-Immediate 200 integer
+ATTRIBUTE Ascend-Require-Auth 201 integer
+ATTRIBUTE Ascend-Number-Sessions 202 string
+ATTRIBUTE Ascend-Authen-Alias 203 string
+ATTRIBUTE Ascend-Token-Expiry 204 integer
+ATTRIBUTE Ascend-Menu-Selector 205 string
+ATTRIBUTE Ascend-Menu-Item 206 string
+ATTRIBUTE Ascend-PW-Warntime 207 integer
+ATTRIBUTE Ascend-PW-Lifetime 208 integer
+ATTRIBUTE Ascend-IP-Direct 209 ipaddr
+ATTRIBUTE Ascend-PPP-VJ-Slot-Comp 210 integer
+ATTRIBUTE Ascend-PPP-VJ-1172 211 integer
+ATTRIBUTE Ascend-PPP-Async-Map 212 integer
+ATTRIBUTE Ascend-Third-Prompt 213 string
+ATTRIBUTE Ascend-Send-Secret 214 string encrypt=3
+ATTRIBUTE Ascend-Receive-Secret 215 string encrypt=3
+ATTRIBUTE Ascend-IPX-Peer-Mode 216 integer
+ATTRIBUTE Ascend-IP-Pool-Definition 217 string
+ATTRIBUTE Ascend-Assign-IP-Pool 218 integer
+ATTRIBUTE Ascend-FR-Direct 219 integer
+ATTRIBUTE Ascend-FR-Direct-Profile 220 string
+ATTRIBUTE Ascend-FR-Direct-DLCI 221 integer
+ATTRIBUTE Ascend-Handle-IPX 222 integer
+ATTRIBUTE Ascend-Netware-timeout 223 integer
+ATTRIBUTE Ascend-IPX-Alias 224 integer
+ATTRIBUTE Ascend-Metric 225 integer
+ATTRIBUTE Ascend-PRI-Number-Type 226 integer
+ATTRIBUTE Ascend-Dial-Number 227 string
+ATTRIBUTE Ascend-Route-IP 228 integer
+ATTRIBUTE Ascend-Route-IPX 229 integer
+ATTRIBUTE Ascend-Bridge 230 integer
+ATTRIBUTE Ascend-Send-Auth 231 integer
+ATTRIBUTE Ascend-Send-Passwd 232 string
+ATTRIBUTE Ascend-Link-Compression 233 integer
+ATTRIBUTE Ascend-Target-Util 234 integer
+ATTRIBUTE Ascend-Maximum-Channels 235 integer
+ATTRIBUTE Ascend-Inc-Channel-Count 236 integer
+ATTRIBUTE Ascend-Dec-Channel-Count 237 integer
+ATTRIBUTE Ascend-Seconds-Of-History 238 integer
+ATTRIBUTE Ascend-History-Weigh-Type 239 integer
+ATTRIBUTE Ascend-Add-Seconds 240 integer
+ATTRIBUTE Ascend-Remove-Seconds 241 integer
+ATTRIBUTE Ascend-Data-Filter 242 abinary
+ATTRIBUTE Ascend-Call-Filter 243 abinary
+ATTRIBUTE Ascend-Idle-Limit 244 integer
+ATTRIBUTE Ascend-Preempt-Limit 245 integer
+ATTRIBUTE Ascend-Callback 246 integer
+ATTRIBUTE Ascend-Data-Svc 247 integer
+ATTRIBUTE Ascend-Force-56 248 integer
+ATTRIBUTE Ascend-Billing-Number 249 string
+ATTRIBUTE Ascend-Call-By-Call 250 integer
+ATTRIBUTE Ascend-Transit-Number 251 string
+ATTRIBUTE Ascend-Host-Info 252 string
+ATTRIBUTE Ascend-PPP-Address 253 ipaddr
+ATTRIBUTE Ascend-MPP-Idle-Percent 254 integer
+ATTRIBUTE Ascend-Xmit-Rate 255 integer
+
+# Ascend protocols
+VALUE Service-Type Dialout-Framed-User 5
+VALUE Framed-Protocol Ascend-ARA 255
+VALUE Framed-Protocol Ascend-MPP 256
+VALUE Framed-Protocol Ascend-EURAW 257
+VALUE Framed-Protocol Ascend-EUUI 258
+VALUE Framed-Protocol Ascend-X25 259
+VALUE Framed-Protocol Ascend-COMB 260
+VALUE Framed-Protocol Ascend-FR 261
+VALUE Framed-Protocol Ascend-MP 262
+VALUE Framed-Protocol Ascend-FR-CIR 263
+
+#
+# Ascend specific extensions
+# Used by ASCEND MAX/Pipeline products (see above)
+#
+
+VALUE Ascend-Source-IP-Check Source-IP-Check-No 0
+VALUE Ascend-Source-IP-Check Source-IP-Check-Yes 1
+VALUE Ascend-CBCP-Enable CBCP-Not-Enabled 0
+VALUE Ascend-CBCP-Enable CBCP-Enabled 1
+VALUE Ascend-CBCP-Mode CBCP-No-Callback 1
+VALUE Ascend-CBCP-Mode CBCP-User-Callback 2
+VALUE Ascend-CBCP-Mode CBCP-Profile-Callback 3
+VALUE Ascend-CBCP-Mode CBCP-Any-Or-No 7
+VALUE Ascend-CBCP-Mode CBCP-Off 8
+VALUE Ascend-FR-Direct FR-Direct-No 0
+VALUE Ascend-FR-Direct FR-Direct-Yes 1
+VALUE Ascend-Handle-IPX Handle-IPX-None 0
+VALUE Ascend-Handle-IPX Handle-IPX-Client 1
+VALUE Ascend-Handle-IPX Handle-IPX-Server 2
+VALUE Ascend-IPX-Peer-Mode IPX-Peer-Router 0
+VALUE Ascend-IPX-Peer-Mode IPX-Peer-Dialin 1
+VALUE Ascend-Call-Type Switched 0
+VALUE Ascend-Call-Type Nailed 1
+VALUE Ascend-Call-Type Nailed/Mpp 2
+VALUE Ascend-Call-Type Perm/Switched 3
+VALUE Ascend-Call-Type AO/DI 6
+VALUE Ascend-Call-Type MegaMax 7
+VALUE Ascend-FT1-Caller FT1-No 0
+VALUE Ascend-FT1-Caller FT1-Yes 1
+VALUE Ascend-PRI-Number-Type Unknown-Number 0
+VALUE Ascend-PRI-Number-Type Intl-Number 1
+VALUE Ascend-PRI-Number-Type National-Number 2
+VALUE Ascend-PRI-Number-Type Net-Specific-Number 3
+VALUE Ascend-PRI-Number-Type Local-Number 4
+VALUE Ascend-PRI-Number-Type Abbrev-Number 5
+
+VALUE Ascend-Route-IP Route-IP-No 0
+VALUE Ascend-Route-IP Route-IP-Yes 1
+VALUE Ascend-Route-IPX Route-IPX-No 0
+VALUE Ascend-Route-IPX Route-IPX-Yes 1
+VALUE Ascend-Bridge Bridge-No 0
+VALUE Ascend-Bridge Bridge-Yes 1
+VALUE Ascend-TS-Idle-Mode TS-Idle-None 0
+VALUE Ascend-TS-Idle-Mode TS-Idle-Input 1
+VALUE Ascend-TS-Idle-Mode TS-Idle-Input-Output 2
+
+VALUE Ascend-Send-Auth Send-Auth-None 0
+VALUE Ascend-Send-Auth Send-Auth-PAP 1
+VALUE Ascend-Send-Auth Send-Auth-CHAP 2
+VALUE Ascend-Send-Auth Send-Auth-MS-CHAP 3
+
+VALUE Ascend-Link-Compression Link-Comp-None 0
+VALUE Ascend-Link-Compression Link-Comp-Stac 1
+VALUE Ascend-Link-Compression Link-Comp-Stac-Draft-9 2
+VALUE Ascend-Link-Compression Link-Comp-MS-Stac 3
+VALUE Ascend-History-Weigh-Type History-Constant 0
+VALUE Ascend-History-Weigh-Type History-Linear 1
+VALUE Ascend-History-Weigh-Type History-Quadratic 2
+VALUE Ascend-Callback Callback-No 0
+VALUE Ascend-Callback Callback-Yes 1
+VALUE Ascend-Expect-Callback Expect-Callback-No 0
+VALUE Ascend-Expect-Callback Expect-Callback-Yes 1
+VALUE Ascend-Data-Svc Switched-Voice-Bearer 0
+VALUE Ascend-Data-Svc Nailed-56KR 1
+VALUE Ascend-Data-Svc Nailed-64K 2
+VALUE Ascend-Data-Svc Switched-64KR 3
+VALUE Ascend-Data-Svc Switched-56K 4
+VALUE Ascend-Data-Svc Switched-384KR 5
+VALUE Ascend-Data-Svc Switched-384K 6
+VALUE Ascend-Data-Svc Switched-1536K 7
+VALUE Ascend-Data-Svc Switched-1536KR 8
+VALUE Ascend-Data-Svc Switched-128K 9
+VALUE Ascend-Data-Svc Switched-192K 10
+VALUE Ascend-Data-Svc Switched-256K 11
+VALUE Ascend-Data-Svc Switched-320K 12
+VALUE Ascend-Data-Svc Switched-384K-MR 13
+VALUE Ascend-Data-Svc Switched-448K 14
+VALUE Ascend-Data-Svc Switched-512K 15
+VALUE Ascend-Data-Svc Switched-576K 16
+VALUE Ascend-Data-Svc Switched-640K 17
+VALUE Ascend-Data-Svc Switched-704K 18
+VALUE Ascend-Data-Svc Switched-768K 19
+VALUE Ascend-Data-Svc Switched-832K 20
+VALUE Ascend-Data-Svc Switched-896K 21
+VALUE Ascend-Data-Svc Switched-960K 22
+VALUE Ascend-Data-Svc Switched-1024K 23
+VALUE Ascend-Data-Svc Switched-1088K 24
+VALUE Ascend-Data-Svc Switched-1152K 25
+VALUE Ascend-Data-Svc Switched-1216K 26
+VALUE Ascend-Data-Svc Switched-1280K 27
+VALUE Ascend-Data-Svc Switched-1344K 28
+VALUE Ascend-Data-Svc Switched-1408K 29
+VALUE Ascend-Data-Svc Switched-1472K 30
+VALUE Ascend-Data-Svc Switched-1600K 31
+VALUE Ascend-Data-Svc Switched-1664K 32
+VALUE Ascend-Data-Svc Switched-1728K 33
+VALUE Ascend-Data-Svc Switched-1792K 34
+VALUE Ascend-Data-Svc Switched-1856K 35
+VALUE Ascend-Data-Svc Switched-1920K 36
+VALUE Ascend-Data-Svc Switched-inherited 37
+VALUE Ascend-Data-Svc Switched-restricted-bearer-x30 38
+VALUE Ascend-Data-Svc Switched-clear-bearer-v110 39
+VALUE Ascend-Data-Svc Switched-restricted-64-x30 40
+VALUE Ascend-Data-Svc Switched-clear-56-v110 41
+VALUE Ascend-Data-Svc Switched-modem 42
+VALUE Ascend-Data-Svc Switched-atmodem 43
+VALUE Ascend-Data-Svc Switched-V110-24-56 45
+VALUE Ascend-Data-Svc Switched-V110-48-56 46
+VALUE Ascend-Data-Svc Switched-V110-96-56 47
+VALUE Ascend-Data-Svc Switched-V110-192-56 48
+VALUE Ascend-Data-Svc Switched-V110-384-56 49
+VALUE Ascend-Data-Svc Switched-V110-24-56R 50
+VALUE Ascend-Data-Svc Switched-V110-48-56R 51
+VALUE Ascend-Data-Svc Switched-V110-96-56R 52
+VALUE Ascend-Data-Svc Switched-V110-192-56R 53
+VALUE Ascend-Data-Svc Switched-V110-384-56R 54
+VALUE Ascend-Data-Svc Switched-V110-24-64 55
+VALUE Ascend-Data-Svc Switched-V110-48-64 56
+VALUE Ascend-Data-Svc Switched-V110-96-64 57
+VALUE Ascend-Data-Svc Switched-V110-192-64 58
+VALUE Ascend-Data-Svc Switched-V110-384-64 59
+VALUE Ascend-Data-Svc Switched-V110-24-64R 60
+VALUE Ascend-Data-Svc Switched-V110-48-64R 61
+VALUE Ascend-Data-Svc Switched-V110-96-64R 62
+VALUE Ascend-Data-Svc Switched-V110-384-64R 64
+VALUE Ascend-Data-Svc Switched-V110-192-64R 63
+
+VALUE Ascend-Data-Svc Switched-Pots 68
+VALUE Ascend-Data-Svc Switched-ATM 69
+VALUE Ascend-Data-Svc Switched-FR 70
+
+VALUE Ascend-Force-56 Force-56-No 0
+VALUE Ascend-Force-56 Force-56-Yes 1
+VALUE Ascend-PW-Lifetime Lifetime-In-Days 0
+VALUE Ascend-PW-Warntime Days-Of-Warning 0
+VALUE Ascend-PPP-VJ-1172 PPP-VJ-1172 1
+VALUE Ascend-PPP-VJ-Slot-Comp VJ-Slot-Comp-No 1
+VALUE Ascend-Require-Auth Not-Require-Auth 0
+VALUE Ascend-Require-Auth Require-Auth 1
+VALUE Ascend-Token-Immediate Tok-Imm-No 0
+VALUE Ascend-Token-Immediate Tok-Imm-Yes 1
+VALUE Ascend-DBA-Monitor DBA-Transmit 0
+VALUE Ascend-DBA-Monitor DBA-Transmit-Recv 1
+VALUE Ascend-DBA-Monitor DBA-None 2
+VALUE Ascend-FR-Type Ascend-FR-DTE 0
+VALUE Ascend-FR-Type Ascend-FR-DCE 1
+VALUE Ascend-FR-Type Ascend-FR-NNI 2
+VALUE Ascend-FR-Link-Mgt Ascend-FR-No-Link-Mgt 0
+VALUE Ascend-FR-Link-Mgt Ascend-FR-T1-617D 1
+VALUE Ascend-FR-Link-Mgt Ascend-FR-Q-933A 2
+VALUE Ascend-FR-LinkUp Ascend-LinkUp-Default 0
+VALUE Ascend-FR-LinkUp Ascend-LinkUp-AlwaysUp 1
+VALUE Ascend-Multicast-Client Multicast-No 0
+VALUE Ascend-Multicast-Client Multicast-Yes 1
+VALUE Ascend-User-Acct-Type Ascend-User-Acct-None 0
+VALUE Ascend-User-Acct-Type Ascend-User-Acct-User 1
+VALUE Ascend-User-Acct-Type Ascend-User-Acct-User-Default 2
+VALUE Ascend-User-Acct-Base Base-10 0
+VALUE Ascend-User-Acct-Base Base-16 1
+VALUE Ascend-DHCP-Reply DHCP-Reply-No 0
+VALUE Ascend-DHCP-Reply DHCP-Reply-Yes 1
+VALUE Ascend-Client-Assign-DNS DNS-Assign-No 0
+VALUE Ascend-Client-Assign-DNS DNS-Assign-Yes 1
+VALUE Ascend-Event-Type Ascend-ColdStart 1
+VALUE Ascend-Event-Type Ascend-Session-Event 2
+VALUE Ascend-BACP-Enable BACP-No 0
+VALUE Ascend-BACP-Enable BACP-Yes 1
+
+VALUE Ascend-Dialout-Allowed Dialout-Not-Allowed 0
+VALUE Ascend-Dialout-Allowed Dialout-Allowed 1
+
+VALUE Ascend-Shared-Profile-Enable Shared-Profile-No 0
+VALUE Ascend-Shared-Profile-Enable Shared-Profile-Yes 1
+
+VALUE Ascend-Temporary-Rtes Temp-Rtes-No 0
+VALUE Ascend-Temporary-Rtes Temp-Rtes-Yes 1
+
+# Ascend Disconnect Cause Values
+
+VALUE Ascend-Disconnect-Cause No-Reason 0
+VALUE Ascend-Disconnect-Cause Not-Applicable 1
+VALUE Ascend-Disconnect-Cause Unknown 2
+VALUE Ascend-Disconnect-Cause Call-Disconnected 3
+VALUE Ascend-Disconnect-Cause CLID-Authentication-Failed 4
+VALUE Ascend-Disconnect-Cause CLID-RADIUS-Timeout 5
+
+VALUE Ascend-Disconnect-Cause Modem-No-DCD 10
+VALUE Ascend-Disconnect-Cause DCD-Detected-Then-Inactive 11
+VALUE Ascend-Disconnect-Cause Modem-Invalid-Result-Codes 12
+
+VALUE Ascend-Disconnect-Cause TermSrv-User-Quit 20
+VALUE Ascend-Disconnect-Cause TermSrv-Idle-Timeout 21
+VALUE Ascend-Disconnect-Cause TermSrv-Exit-Telnet 22
+VALUE Ascend-Disconnect-Cause TermSrv-No-IPaddr 23
+VALUE Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP 24
+VALUE Ascend-Disconnect-Cause TermSrv-Exit-Login-Failed 25
+VALUE Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP-Disabled 26
+VALUE Ascend-Disconnect-Cause TermSrv-CTRL-C-In-Login 27
+VALUE Ascend-Disconnect-Cause TermSrv-Destroyed 28
+VALUE Ascend-Disconnect-Cause TermSrv-User-Closed-VCon 29
+
+VALUE Ascend-Disconnect-Cause TermSrv-VCon-Destroyed 30
+VALUE Ascend-Disconnect-Cause TermSrv-Exit-Rlogin 31
+VALUE Ascend-Disconnect-Cause TermSrv-Bad-Rlogin-Option 32
+VALUE Ascend-Disconnect-Cause TermSrv-Not-Enough-Resources 33
+
+VALUE Ascend-Disconnect-Cause MPP-No-NULL-Msg-Timeout 35
+
+VALUE Ascend-Disconnect-Cause PPP-LCP-Timeout 40
+VALUE Ascend-Disconnect-Cause PPP-LCP-Negotion-Failed 41
+VALUE Ascend-Disconnect-Cause PPP-PAP-Auth-Failed 42
+VALUE Ascend-Disconnect-Cause PPP-CHAP-Auth-Failed 43
+VALUE Ascend-Disconnect-Cause PPP-Rmt-Auth-Failed 44
+VALUE Ascend-Disconnect-Cause PPP-Rcv-Terminate-Req 45
+VALUE Ascend-Disconnect-Cause PPP-Rcv-Close-Event 46
+VALUE Ascend-Disconnect-Cause PPP-No-NCPs-Open 47
+VALUE Ascend-Disconnect-Cause PPP-MP-Bundle-Unknown 48
+VALUE Ascend-Disconnect-Cause PPP-LCP-Close-MP-Add-Fail 49
+
+VALUE Ascend-Disconnect-Cause Session-Table-Full 50
+VALUE Ascend-Disconnect-Cause Out-Of-Resources 51
+VALUE Ascend-Disconnect-Cause Invalid-IP-Address 52
+VALUE Ascend-Disconnect-Cause Hostname-Resolution-Failed 53
+VALUE Ascend-Disconnect-Cause Bad-Or-Missing-Port-Number 54
+
+VALUE Ascend-Disconnect-Cause Host-Reset 60
+VALUE Ascend-Disconnect-Cause Connection-Refused 61
+VALUE Ascend-Disconnect-Cause Connection-Timeout 62
+VALUE Ascend-Disconnect-Cause Connection-Closed 63
+VALUE Ascend-Disconnect-Cause Network-Unreachable 64
+VALUE Ascend-Disconnect-Cause Host-Unreachable 65
+VALUE Ascend-Disconnect-Cause Network-Unreachable-Admin 66
+VALUE Ascend-Disconnect-Cause Host-Unreachable-Admin 67
+VALUE Ascend-Disconnect-Cause Port-Unreachable 68
+
+VALUE Ascend-Disconnect-Cause Session-Timeout 100
+VALUE Ascend-Disconnect-Cause Invalid-Incoming-User 101
+VALUE Ascend-Disconnect-Cause Disconnect-Due-To-Callback 102
+
+VALUE Ascend-Disconnect-Cause Proto-Disabled-Or-Unsupported 120
+
+VALUE Ascend-Disconnect-Cause Disconnect-Req-By-RADIUS 150
+VALUE Ascend-Disconnect-Cause Disconnect-Req-By-Local-Admin 151
+
+VALUE Ascend-Disconnect-Cause V110-Timeout-Sync-Retry-Exceed 160
+
+VALUE Ascend-Disconnect-Cause PPP-Auth-Timeout-Exceeded 170
+VALUE Ascend-Disconnect-Cause User-Executed-Do-Hangup 180
+VALUE Ascend-Disconnect-Cause Remote-End-Hung-Up 185
+VALUE Ascend-Disconnect-Cause Resource-Has-Been-Quiesced 190
+VALUE Ascend-Disconnect-Cause Max-Call-Duration-Reached 195
+
+# ascend connect progress codes
+VALUE Ascend-Connect-Progress No-Progress 0
+VALUE Ascend-Connect-Progress Call-Up 10
+VALUE Ascend-Connect-Progress Modem-Up 30
+VALUE Ascend-Connect-Progress Modem-Awaiting-DCD 31
+VALUE Ascend-Connect-Progress Modem-Awaiting-Codes 32
+VALUE Ascend-Connect-Progress TermSrv-Started 40
+VALUE Ascend-Connect-Progress TermSrv-Raw-TCP-Started 41
+VALUE Ascend-Connect-Progress TermSrv-Telnet-Started 42
+VALUE Ascend-Connect-Progress TermSrv-Raw-TCP-Connected 43
+VALUE Ascend-Connect-Progress TermSrv-Telnet-Connected 44
+VALUE Ascend-Connect-Progress TermSrv-Rlogin-Started 45
+VALUE Ascend-Connect-Progress TermSrv-Rlogin-Connected 46
+VALUE Ascend-Connect-Progress Modem-Outdial-Call-Up 50
+VALUE Ascend-Connect-Progress LAN-Session-Up 60
+VALUE Ascend-Connect-Progress LCP-Opening 61
+VALUE Ascend-Connect-Progress CCP-Opening 62
+VALUE Ascend-Connect-Progress IPNCP-Opening 63
+VALUE Ascend-Connect-Progress BNCP-Opening 64
+VALUE Ascend-Connect-Progress LCP-Opened 65
+VALUE Ascend-Connect-Progress CCP-Opened 66
+VALUE Ascend-Connect-Progress IPNCP-Opened 67
+VALUE Ascend-Connect-Progress BNCP-Opened 68
+VALUE Ascend-Connect-Progress LCP-State-Initial 69
+VALUE Ascend-Connect-Progress LCP-State-Starting 70
+VALUE Ascend-Connect-Progress LCP-State-Closed 71
+VALUE Ascend-Connect-Progress LCP-State-Stopped 72
+VALUE Ascend-Connect-Progress LCP-State-Closing 73
+VALUE Ascend-Connect-Progress LCP-State-Stopping 74
+VALUE Ascend-Connect-Progress LCP-State-Request-Sent 75
+VALUE Ascend-Connect-Progress LCP-State-Ack-Received 76
+VALUE Ascend-Connect-Progress LCP-State-Ack-Sent 77
+VALUE Ascend-Connect-Progress IPXNCP-Opened 80
+VALUE Ascend-Connect-Progress ATNCP-Opened 81
+VALUE Ascend-Connect-Progress BACP-Opening 82
+VALUE Ascend-Connect-Progress BACP-Opened 83
+VALUE Ascend-Connect-Progress V110-Up 90
+VALUE Ascend-Connect-Progress V110-State-Opened 91
+VALUE Ascend-Connect-Progress V110-State-Carrier 92
+VALUE Ascend-Connect-Progress V110-State-Reset 93
+VALUE Ascend-Connect-Progress V110-State-Closed 94
+VALUE Ascend-ATM-Direct ATM-Direct-No 0
+VALUE Ascend-ATM-Direct ATM-Direct-Yes 1
+VALUE Ascend-ATM-Fault-Management VC-End-To-End-Loopback 2
+VALUE Ascend-ATM-Fault-Management VC-No-Loopback 0
+VALUE Ascend-ATM-Fault-Management VC-Segment-Loopback 1
+VALUE Ascend-Appletalk-Peer-Mode Appletalk-Peer-Dialin 1
+VALUE Ascend-Appletalk-Peer-Mode Appletalk-Peer-Router 0
+VALUE Ascend-Auth-Type Auth-Any 2
+VALUE Ascend-Auth-Type Auth-CHAP 4
+VALUE Ascend-Auth-Type Auth-Default 1
+VALUE Ascend-Auth-Type Auth-MS-CHAP 5
+VALUE Ascend-Auth-Type Auth-None 0
+VALUE Ascend-Auth-Type Auth-PAP 3
+VALUE Ascend-BIR-Enable BIR-Enable-No 0
+VALUE Ascend-BIR-Enable BIR-Enable-Yes 1
+VALUE Ascend-BIR-Proxy BIR-Proxy-No 0
+VALUE Ascend-BIR-Proxy BIR-Proxy-Yes 1
+VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-Allowed 1
+VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-None 0
+VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-Required 2
+VALUE Ascend-Bridge-Non-PPPoE Bridge-Non-PPPoE-No 0
+VALUE Ascend-Bridge-Non-PPPoE Bridge-Non-PPPoE-Yes 1
+VALUE Ascend-Cache-Refresh Refresh-No 0
+VALUE Ascend-Cache-Refresh Refresh-Yes 1
+VALUE Ascend-Call-Direction Ascend-Call-Direction-Incoming 0
+VALUE Ascend-Call-Direction Ascend-Call-Direction-Outgoing 1
+VALUE Ascend-Calling-Id-Number-Plan Data 3
+VALUE Ascend-Calling-Id-Number-Plan ISDN-Telephony 1
+VALUE Ascend-Calling-Id-Number-Plan National 8
+VALUE Ascend-Calling-Id-Number-Plan Private 9
+VALUE Ascend-Calling-Id-Number-Plan Telex 4
+VALUE Ascend-Calling-Id-Number-Plan Unknown 0
+VALUE Ascend-Calling-Id-Presentatn Allowed 0
+VALUE Ascend-Calling-Id-Presentatn Number-Not-Available 2
+VALUE Ascend-Calling-Id-Presentatn Restricted 1
+VALUE Ascend-Calling-Id-Screening Network-Provided 3
+VALUE Ascend-Calling-Id-Screening User-Not-Screened 0
+VALUE Ascend-Calling-Id-Screening User-Provided-Failed 2
+VALUE Ascend-Calling-Id-Screening User-Provided-Passed 1
+VALUE Ascend-Calling-Id-Type-Of-Num Abbreviated-Number 6
+VALUE Ascend-Calling-Id-Type-Of-Num International-Number 1
+VALUE Ascend-Calling-Id-Type-Of-Num National-Number 2
+VALUE Ascend-Calling-Id-Type-Of-Num Network-Specific 3
+VALUE Ascend-Calling-Id-Type-Of-Num Subscriber-Number 4
+VALUE Ascend-Calling-Id-Type-Of-Num Unknown 0
+VALUE Ascend-Ckt-Type Ascend-PVC 0
+VALUE Ascend-Ckt-Type Ascend-SVC 1
+VALUE Ascend-Client-Assign-WINS WINS-Assign-No 0
+VALUE Ascend-Client-Assign-WINS WINS-Assign-Yes 1
+
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1280000 10
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1600000 9
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1920000 8
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2240000 7
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2560000 6
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2688000 5
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-3200000 4
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-4480000 3
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-5120000 2
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-6272000 1
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-640000 12
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-7168000 0
+VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-960000 11
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-128000 121
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1280000 114
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1600000 113
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1920000 112
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2240000 111
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-256000 120
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2560000 110
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2688000 109
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-3200000 108
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-384000 119
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-4480000 107
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-512000 118
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-5120000 106
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-6272000 105
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-640000 117
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-7168000 104
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-768000 116
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-8000000 103
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-8960000 102
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-9504000 101
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-960000 115
+VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-auto 100
+VALUE Ascend-Dsl-Rate-Mode Rate-Mode-AutoBaud 1
+VALUE Ascend-Dsl-Rate-Mode Rate-Mode-Single 2
+VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslCap 2
+VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslDmt 4
+VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslDmtCell 3
+VALUE Ascend-Dsl-Rate-Type Rate-Type-Disabled 0
+VALUE Ascend-Dsl-Rate-Type Rate-Type-Sdsl 1
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-896000 153
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-1088000 50
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-272000 56
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-408000 55
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-544000 54
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-680000 53
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-816000 52
+VALUE Ascend-Dsl-Upstream-Limit adslcap-up-952000 51
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-1088000 151
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-128000 160
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-256000 159
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-384000 158
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-512000 157
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-640000 156
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-768000 155
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-800000 154
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-928000 152
+VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-auto 150
+VALUE Ascend-Dsl-Upstream-Limit sdsl-1168000 5
+VALUE Ascend-Dsl-Upstream-Limit sdsl-144000 0
+VALUE Ascend-Dsl-Upstream-Limit sdsl-1552000 6
+VALUE Ascend-Dsl-Upstream-Limit sdsl-2320000 7
+VALUE Ascend-Dsl-Upstream-Limit sdsl-272000 1
+VALUE Ascend-Dsl-Upstream-Limit sdsl-400000 2
+VALUE Ascend-Dsl-Upstream-Limit sdsl-528000 3
+VALUE Ascend-Dsl-Upstream-Limit sdsl-784000 4
+VALUE Ascend-FR-Link-Status-Dlci Ascend-FR-LMI-Dlci-0 0
+VALUE Ascend-FR-Link-Status-Dlci Ascend-FR-LMI-Dlci-1023 1023
+VALUE Ascend-Filter-Required Required-No 0
+VALUE Ascend-Filter-Required Required-Yes 1
+VALUE Ascend-IP-Pool-Chaining IP-Pool-Chaining-No 0
+VALUE Ascend-IP-Pool-Chaining IP-Pool-Chaining-Yes 1
+VALUE Ascend-IP-TOS IP-TOS-Cost 2
+VALUE Ascend-IP-TOS IP-TOS-Disabled 1
+VALUE Ascend-IP-TOS IP-TOS-Latency 16
+VALUE Ascend-IP-TOS IP-TOS-Normal 0
+VALUE Ascend-IP-TOS IP-TOS-Reliability 4
+VALUE Ascend-IP-TOS IP-TOS-Throughput 8
+VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Both 3072
+VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Incoming 1024
+VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Outgoing 2048
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Five 160
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Four 128
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Normal 0
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-One 32
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Seven 224
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Six 192
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Three 96
+VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Two 64
+VALUE Ascend-IPX-Header-Compression IPX-Header-Compression-No 0
+VALUE Ascend-IPX-Header-Compression IPX-Header-Compression-Yes 1
+VALUE Ascend-NAS-Port-Format 1_2_2 3
+VALUE Ascend-NAS-Port-Format 2_4_5_5 2
+VALUE Ascend-NAS-Port-Format 2_4_6_4 1
+VALUE Ascend-NAS-Port-Format Unknown 0
+VALUE Ascend-Numbering-Plan-ID ISDN-Numbering-Plan 1
+VALUE Ascend-Numbering-Plan-ID Private-Numbering-Plan 9
+VALUE Ascend-Numbering-Plan-ID Unknown-Numbering-Plan 0
+VALUE Ascend-PPPoE-Enable PPPoE-No 0
+VALUE Ascend-PPPoE-Enable PPPoE-Yes 1
+VALUE Ascend-Port-Redir-Protocol Ascend-Proto-TCP 6
+VALUE Ascend-Port-Redir-Protocol Ascend-Proto-UDP 17
+VALUE Ascend-Private-Route-Required Required-No 0
+VALUE Ascend-Private-Route-Required Required-Yes 1
+VALUE Ascend-Route-Appletalk Route-Appletalk-No 0
+VALUE Ascend-Route-Appletalk Route-Appletalk-Yes 1
+VALUE Ascend-SVC-Enabled Ascend-SVC-Enabled-No 0
+VALUE Ascend-SVC-Enabled Ascend-SVC-Enabled-Yes 1
+
+VALUE Ascend-Service-Type Ascend-Service-Type-ATM 20
+VALUE Ascend-Service-Type Ascend-Service-Type-Combinet 7
+VALUE Ascend-Service-Type Ascend-Service-Type-EuRaw 9
+VALUE Ascend-Service-Type Ascend-Service-Type-EuUi 10
+VALUE Ascend-Service-Type Ascend-Service-Type-FR 8
+VALUE Ascend-Service-Type Ascend-Service-Type-HdlcNrm 21
+VALUE Ascend-Service-Type Ascend-Service-Type-IpFax 19
+VALUE Ascend-Service-Type Ascend-Service-Type-MP 15
+VALUE Ascend-Service-Type Ascend-Service-Type-MPP 5
+VALUE Ascend-Service-Type Ascend-Service-Type-NetToNet 25
+VALUE Ascend-Service-Type Ascend-Service-Type-None 1
+VALUE Ascend-Service-Type Ascend-Service-Type-NotUsed 0
+VALUE Ascend-Service-Type Ascend-Service-Type-Other 2
+VALUE Ascend-Service-Type Ascend-Service-Type-PPP 3
+VALUE Ascend-Service-Type Ascend-Service-Type-PseuTunPPP 18
+VALUE Ascend-Service-Type Ascend-Service-Type-RawTcp 13
+VALUE Ascend-Service-Type Ascend-Service-Type-Slip 4
+VALUE Ascend-Service-Type Ascend-Service-Type-Telnet 11
+VALUE Ascend-Service-Type Ascend-Service-Type-TelnetBin 12
+VALUE Ascend-Service-Type Ascend-Service-Type-TermServer 14
+VALUE Ascend-Service-Type Ascend-Service-Type-VirtualConn 16
+VALUE Ascend-Service-Type Ascend-Service-Type-Visa2 23
+VALUE Ascend-Service-Type Ascend-Service-Type-VoIp 22
+VALUE Ascend-Service-Type Ascend-Service-Type-X25 6
+VALUE Ascend-Service-Type Ascend-Service-Type-X25DChan 17
+VALUE Ascend-Session-Type Ascend-Session-G711-Alaw 3
+VALUE Ascend-Session-Type Ascend-Session-G711-Ulaw 2
+VALUE Ascend-Session-Type Ascend-Session-G723 4
+VALUE Ascend-Session-Type Ascend-Session-G723-64KPS 6
+VALUE Ascend-Session-Type Ascend-Session-G728 7
+VALUE Ascend-Session-Type Ascend-Session-G729 5
+VALUE Ascend-Session-Type Ascend-Session-RT24 8
+VALUE Ascend-Session-Type Ascend-Session-Unknown 1
+VALUE Ascend-Session-Type Ascend-Session-Unused 0
+
+VALUE Ascend-Tunneling-Protocol ATMP-Tunnel 0
+VALUE Ascend-Tunneling-Protocol VTP-Tunnel 1
+
+VALUE Ascend-X25-Pad-X3-Profile CC_SSP 4
+VALUE Ascend-X25-Pad-X3-Profile CC_TSP 5
+VALUE Ascend-X25-Pad-X3-Profile CRT 0
+VALUE Ascend-X25-Pad-X3-Profile CUSTOM 11
+VALUE Ascend-X25-Pad-X3-Profile DEFAULT 2
+VALUE Ascend-X25-Pad-X3-Profile HARDCOPY 6
+VALUE Ascend-X25-Pad-X3-Profile HDX 7
+VALUE Ascend-X25-Pad-X3-Profile INFONET 1
+VALUE Ascend-X25-Pad-X3-Profile NULL 10
+VALUE Ascend-X25-Pad-X3-Profile POS 9
+VALUE Ascend-X25-Pad-X3-Profile SCEN 3
+VALUE Ascend-X25-Pad-X3-Profile SHARK 8
+VALUE Ascend-X25-Reverse-Charging Reverse-Charging-No 0
+VALUE Ascend-X25-Reverse-Charging Reverse-Charging-Yes 1
+END-VENDOR Ascend
#
# Ascend specific extensions
ATTRIBUTE X-Ascend-Call-Block-Duration 124 integer
ATTRIBUTE X-Ascend-Maximum-Call-Duration 125 integer
ATTRIBUTE X-Ascend-Temporary-Rtes 126 integer
-ATTRIBUTE X-Ascend-Tunneling-Protocol 127 integer
-ATTRIBUTE X-Ascend-Shared-Profile-Enable 128 integer
+ATTRIBUTE X-Ascend-Tunneling-Protocol 127 integer
+ATTRIBUTE X-Ascend-Shared-Profile-Enable 128 integer
ATTRIBUTE X-Ascend-Primary-Home-Agent 129 string
ATTRIBUTE X-Ascend-Secondary-Home-Agent 130 string
ATTRIBUTE X-Ascend-Dialout-Allowed 131 integer
ATTRIBUTE X-Ascend-FR-DTE-N393 165 integer
ATTRIBUTE X-Ascend-FR-T391 166 integer
ATTRIBUTE X-Ascend-FR-T392 167 integer
-ATTRIBUTE X-Ascend-Bridge-Address 168 string
-ATTRIBUTE X-Ascend-TS-Idle-Limit 169 integer
-ATTRIBUTE X-Ascend-TS-Idle-Mode 170 integer
-ATTRIBUTE X-Ascend-DBA-Monitor 171 integer
-ATTRIBUTE X-Ascend-Base-Channel-Count 172 integer
+ATTRIBUTE X-Ascend-Bridge-Address 168 string
+ATTRIBUTE X-Ascend-TS-Idle-Limit 169 integer
+ATTRIBUTE X-Ascend-TS-Idle-Mode 170 integer
+ATTRIBUTE X-Ascend-DBA-Monitor 171 integer
+ATTRIBUTE X-Ascend-Base-Channel-Count 172 integer
ATTRIBUTE X-Ascend-Minimum-Channels 173 integer
ATTRIBUTE X-Ascend-IPX-Route 174 string
ATTRIBUTE X-Ascend-FT1-Caller 175 integer
ATTRIBUTE X-Ascend-Authen-Alias 203 string
ATTRIBUTE X-Ascend-Token-Expiry 204 integer
ATTRIBUTE X-Ascend-Menu-Selector 205 string
+
+#
+# These next two attributes conflict with the Digest attributes!
+#
ATTRIBUTE X-Ascend-Menu-Item 206 string
ATTRIBUTE X-Ascend-PW-Warntime 207 integer
+
ATTRIBUTE X-Ascend-PW-Lifetime 208 integer
ATTRIBUTE X-Ascend-IP-Direct 209 ipaddr
ATTRIBUTE X-Ascend-PPP-VJ-Slot-Comp 210 integer
ATTRIBUTE X-Ascend-Xmit-Rate 255 integer
#
-# Ascend vendor-specific attributes.
+# VALUEs for X-Ascend-* attributes, copied verbatim from the
+# VALUEs above, for the VSA versions of Ascend-*.
#
-BEGIN-VENDOR Ascend
-ATTRIBUTE Ascend-Max-Shared-Users 2 integer
-ATTRIBUTE Ascend-UU-Info 7 string
-ATTRIBUTE Ascend-CIR-Timer 9 integer
-ATTRIBUTE Ascend-FR-08-Mode 10 integer
-ATTRIBUTE Ascend-Destination-Nas-Port 11 integer
-ATTRIBUTE Ascend-FR-SVC-Addr 12 string
-ATTRIBUTE Ascend-NAS-Port-Format 13 integer
-ATTRIBUTE Ascend-ATM-Fault-Management 14 integer
-ATTRIBUTE Ascend-ATM-Loopback-Cell-Loss 15 integer
-ATTRIBUTE Ascend-Ckt-Type 16 integer
-ATTRIBUTE Ascend-SVC-Enabled 17 integer
-ATTRIBUTE Ascend-Session-Type 18 integer
-ATTRIBUTE Ascend-H323-Gatekeeper 19 ipaddr
-ATTRIBUTE Ascend-Global-Call-Id 20 string
-ATTRIBUTE Ascend-H323-Conference-Id 21 integer
-ATTRIBUTE Ascend-H323-Fegw-Address 22 ipaddr
-ATTRIBUTE Ascend-H323-Dialed-Time 23 integer
-ATTRIBUTE Ascend-Dialed-Number 24 string
-ATTRIBUTE Ascend-Inter-Arrival-Jitter 25 integer
-ATTRIBUTE Ascend-Dropped-Octets 26 integer
-ATTRIBUTE Ascend-Dropped-Packets 27 integer
-ATTRIBUTE Ascend-Auth-Delay 28 integer
-ATTRIBUTE Ascend-X25-Pad-X3-Profile 29 integer
-ATTRIBUTE Ascend-X25-Pad-X3-Parameters 30 string
-ATTRIBUTE Ascend-Tunnel-VRouter-Name 31 string
-ATTRIBUTE Ascend-X25-Reverse-Charging 32 integer
-ATTRIBUTE Ascend-X25-Nui-Prompt 33 string
-ATTRIBUTE Ascend-X25-Nui-Password-Prompt 34 string
-ATTRIBUTE Ascend-X25-Cug 35 string
-ATTRIBUTE Ascend-X25-Pad-Alias-1 36 string
-ATTRIBUTE Ascend-X25-Pad-Alias-2 37 string
-ATTRIBUTE Ascend-X25-Pad-Alias-3 38 string
-ATTRIBUTE Ascend-X25-X121-Address 39 string
-ATTRIBUTE Ascend-X25-Nui 40 string
-ATTRIBUTE Ascend-X25-Rpoa 41 string
-ATTRIBUTE Ascend-X25-Pad-Prompt 42 string
-ATTRIBUTE Ascend-X25-Pad-Banner 43 string
-ATTRIBUTE Ascend-X25-Profile-Name 44 string
-ATTRIBUTE Ascend-Recv-Name 45 string
-ATTRIBUTE Ascend-Bi-Directional-Auth 46 integer
-ATTRIBUTE Ascend-MTU 47 integer
-ATTRIBUTE Ascend-Call-Direction 48 integer
-ATTRIBUTE Ascend-Service-Type 49 integer
-ATTRIBUTE Ascend-Filter-Required 50 integer
-ATTRIBUTE Ascend-Traffic-Shaper 51 integer
-ATTRIBUTE Ascend-Access-Intercept-LEA 52 string
-ATTRIBUTE Ascend-Access-Intercept-Log 53 string
-ATTRIBUTE Ascend-Private-Route-Table-ID 54 string
-ATTRIBUTE Ascend-Private-Route-Required 55 integer
-ATTRIBUTE Ascend-Cache-Refresh 56 integer
-ATTRIBUTE Ascend-Cache-Time 57 integer
-ATTRIBUTE Ascend-Egress-Enabled 58 integer
-ATTRIBUTE Ascend-QOS-Upstream 59 string
-ATTRIBUTE Ascend-QOS-Downstream 60 string
-ATTRIBUTE Ascend-ATM-Connect-Vpi 61 integer
-ATTRIBUTE Ascend-ATM-Connect-Vci 62 integer
-ATTRIBUTE Ascend-ATM-Connect-Group 63 integer
-ATTRIBUTE Ascend-ATM-Group 64 integer
-ATTRIBUTE Ascend-IPX-Header-Compression 65 integer
-ATTRIBUTE Ascend-Calling-Id-Type-Of-Num 66 integer
-ATTRIBUTE Ascend-Calling-Id-Number-Plan 67 integer
-ATTRIBUTE Ascend-Calling-Id-Presentatn 68 integer
-ATTRIBUTE Ascend-Calling-Id-Screening 69 integer
-ATTRIBUTE Ascend-BIR-Enable 70 integer
-ATTRIBUTE Ascend-BIR-Proxy 71 integer
-ATTRIBUTE Ascend-BIR-Bridge-Group 72 integer
-ATTRIBUTE Ascend-IPSEC-Profile 73 string
-ATTRIBUTE Ascend-PPPoE-Enable 74 integer
-ATTRIBUTE Ascend-Bridge-Non-PPPoE 75 integer
-ATTRIBUTE Ascend-ATM-Direct 76 integer
-ATTRIBUTE Ascend-ATM-Direct-Profile 77 string
-ATTRIBUTE Ascend-Client-Primary-WINS 78 ipaddr
-ATTRIBUTE Ascend-Client-Secondary-WINS 79 ipaddr
-ATTRIBUTE Ascend-Client-Assign-WINS 80 integer
-ATTRIBUTE Ascend-Auth-Type 81 integer
-ATTRIBUTE Ascend-Port-Redir-Protocol 82 integer
-ATTRIBUTE Ascend-Port-Redir-Portnum 83 integer
-ATTRIBUTE Ascend-Port-Redir-Server 84 ipaddr
-ATTRIBUTE Ascend-IP-Pool-Chaining 85 integer
-ATTRIBUTE Ascend-Owner-IP-Addr 86 ipaddr
-ATTRIBUTE Ascend-IP-TOS 87 integer
-ATTRIBUTE Ascend-IP-TOS-Precedence 88 integer
-ATTRIBUTE Ascend-IP-TOS-Apply-To 89 integer
-ATTRIBUTE Ascend-Filter 90 string
-ATTRIBUTE Ascend-Telnet-Profile 91 string
-ATTRIBUTE Ascend-Dsl-Rate-Type 92 integer
-ATTRIBUTE Ascend-Redirect-Number 93 string
-ATTRIBUTE Ascend-ATM-Vpi 94 integer
-ATTRIBUTE Ascend-ATM-Vci 95 integer
-ATTRIBUTE Ascend-Source-IP-Check 96 integer
-ATTRIBUTE Ascend-Dsl-Rate-Mode 97 integer
-ATTRIBUTE Ascend-Dsl-Upstream-Limit 98 integer
-ATTRIBUTE Ascend-Dsl-Downstream-Limit 99 integer
-ATTRIBUTE Ascend-Dsl-CIR-Recv-Limit 100 integer
-ATTRIBUTE Ascend-Dsl-CIR-Xmit-Limit 101 integer
-ATTRIBUTE Ascend-VRouter-Name 102 string
-ATTRIBUTE Ascend-Source-Auth 103 string
-ATTRIBUTE Ascend-Private-Route 104 string
-ATTRIBUTE Ascend-Numbering-Plan-ID 105 integer
-ATTRIBUTE Ascend-FR-Link-Status-DLCI 106 integer
-ATTRIBUTE Ascend-Calling-Subaddress 107 string
-ATTRIBUTE Ascend-Callback-Delay 108 integer
-ATTRIBUTE Ascend-Endpoint-Disc 109 string
-ATTRIBUTE Ascend-Remote-FW 110 string
-ATTRIBUTE Ascend-Multicast-GLeave-Delay 111 integer
-ATTRIBUTE Ascend-CBCP-Enable 112 integer
-ATTRIBUTE Ascend-CBCP-Mode 113 integer
-ATTRIBUTE Ascend-CBCP-Delay 114 integer
-ATTRIBUTE Ascend-CBCP-Trunk-Group 115 integer
-ATTRIBUTE Ascend-Appletalk-Route 116 string
-ATTRIBUTE Ascend-Appletalk-Peer-Mode 117 integer
-ATTRIBUTE Ascend-Route-Appletalk 118 integer
-ATTRIBUTE Ascend-FCP-Parameter 119 string
-ATTRIBUTE Ascend-Modem-PortNo 120 integer
-ATTRIBUTE Ascend-Modem-SlotNo 121 integer
-ATTRIBUTE Ascend-Modem-ShelfNo 122 integer
-ATTRIBUTE Ascend-Call-Attempt-Limit 123 integer
-ATTRIBUTE Ascend-Call-Block-Duration 124 integer
-ATTRIBUTE Ascend-Maximum-Call-Duration 125 integer
-ATTRIBUTE Ascend-Temporary-Rtes 126 integer
-ATTRIBUTE Ascend-Tunneling-Protocol 127 integer
-ATTRIBUTE Ascend-Shared-Profile-Enable 128 integer
-ATTRIBUTE Ascend-Primary-Home-Agent 129 string
-ATTRIBUTE Ascend-Secondary-Home-Agent 130 string
-ATTRIBUTE Ascend-Dialout-Allowed 131 integer
-ATTRIBUTE Ascend-Client-Gateway 132 ipaddr
-ATTRIBUTE Ascend-BACP-Enable 133 integer
-ATTRIBUTE Ascend-DHCP-Maximum-Leases 134 integer
-ATTRIBUTE Ascend-Client-Primary-DNS 135 ipaddr
-ATTRIBUTE Ascend-Client-Secondary-DNS 136 ipaddr
-ATTRIBUTE Ascend-Client-Assign-DNS 137 integer
-ATTRIBUTE Ascend-User-Acct-Type 138 integer
-ATTRIBUTE Ascend-User-Acct-Host 139 ipaddr
-ATTRIBUTE Ascend-User-Acct-Port 140 integer
-ATTRIBUTE Ascend-User-Acct-Key 141 string
-ATTRIBUTE Ascend-User-Acct-Base 142 integer
-ATTRIBUTE Ascend-User-Acct-Time 143 integer
-ATTRIBUTE Ascend-Assign-IP-Client 144 ipaddr
-ATTRIBUTE Ascend-Assign-IP-Server 145 ipaddr
-ATTRIBUTE Ascend-Assign-IP-Global-Pool 146 string
-ATTRIBUTE Ascend-DHCP-Reply 147 integer
-ATTRIBUTE Ascend-DHCP-Pool-Number 148 integer
-ATTRIBUTE Ascend-Expect-Callback 149 integer
-ATTRIBUTE Ascend-Event-Type 150 integer
-ATTRIBUTE Ascend-Session-Svr-Key 151 string
-ATTRIBUTE Ascend-Multicast-Rate-Limit 152 integer
-ATTRIBUTE Ascend-IF-Netmask 153 ipaddr
-ATTRIBUTE Ascend-Remote-Addr 154 ipaddr
-ATTRIBUTE Ascend-Multicast-Client 155 integer
-ATTRIBUTE Ascend-FR-Circuit-Name 156 string
-ATTRIBUTE Ascend-FR-LinkUp 157 integer
-ATTRIBUTE Ascend-FR-Nailed-Grp 158 integer
-ATTRIBUTE Ascend-FR-Type 159 integer
-ATTRIBUTE Ascend-FR-Link-Mgt 160 integer
-ATTRIBUTE Ascend-FR-N391 161 integer
-ATTRIBUTE Ascend-FR-DCE-N392 162 integer
-ATTRIBUTE Ascend-FR-DTE-N392 163 integer
-ATTRIBUTE Ascend-FR-DCE-N393 164 integer
-ATTRIBUTE Ascend-FR-DTE-N393 165 integer
-ATTRIBUTE Ascend-FR-T391 166 integer
-ATTRIBUTE Ascend-FR-T392 167 integer
-ATTRIBUTE Ascend-Bridge-Address 168 string
-ATTRIBUTE Ascend-TS-Idle-Limit 169 integer
-ATTRIBUTE Ascend-TS-Idle-Mode 170 integer
-ATTRIBUTE Ascend-DBA-Monitor 171 integer
-ATTRIBUTE Ascend-Base-Channel-Count 172 integer
-ATTRIBUTE Ascend-Minimum-Channels 173 integer
-ATTRIBUTE Ascend-IPX-Route 174 string
-ATTRIBUTE Ascend-FT1-Caller 175 integer
-ATTRIBUTE Ascend-Backup 176 string
-ATTRIBUTE Ascend-Call-Type 177 integer
-ATTRIBUTE Ascend-Group 178 string
-ATTRIBUTE Ascend-FR-DLCI 179 integer
-ATTRIBUTE Ascend-FR-Profile-Name 180 string
-ATTRIBUTE Ascend-Ara-PW 181 string
-ATTRIBUTE Ascend-IPX-Node-Addr 182 string
-ATTRIBUTE Ascend-Home-Agent-IP-Addr 183 ipaddr
-ATTRIBUTE Ascend-Home-Agent-Password 184 string
-ATTRIBUTE Ascend-Home-Network-Name 185 string
-ATTRIBUTE Ascend-Home-Agent-UDP-Port 186 integer
-ATTRIBUTE Ascend-Multilink-ID 187 integer
-ATTRIBUTE Ascend-Num-In-Multilink 188 integer
-ATTRIBUTE Ascend-First-Dest 189 ipaddr
-ATTRIBUTE Ascend-Pre-Input-Octets 190 integer
-ATTRIBUTE Ascend-Pre-Output-Octets 191 integer
-ATTRIBUTE Ascend-Pre-Input-Packets 192 integer
-ATTRIBUTE Ascend-Pre-Output-Packets 193 integer
-ATTRIBUTE Ascend-Maximum-Time 194 integer
-ATTRIBUTE Ascend-Disconnect-Cause 195 integer
-ATTRIBUTE Ascend-Connect-Progress 196 integer
-ATTRIBUTE Ascend-Data-Rate 197 integer
-ATTRIBUTE Ascend-PreSession-Time 198 integer
-ATTRIBUTE Ascend-Token-Idle 199 integer
-ATTRIBUTE Ascend-Token-Immediate 200 integer
-ATTRIBUTE Ascend-Require-Auth 201 integer
-ATTRIBUTE Ascend-Number-Sessions 202 string
-ATTRIBUTE Ascend-Authen-Alias 203 string
-ATTRIBUTE Ascend-Token-Expiry 204 integer
-ATTRIBUTE Ascend-Menu-Selector 205 string
-ATTRIBUTE Ascend-Menu-Item 206 string
-ATTRIBUTE Ascend-PW-Warntime 207 integer
-ATTRIBUTE Ascend-PW-Lifetime 208 integer
-ATTRIBUTE Ascend-IP-Direct 209 ipaddr
-ATTRIBUTE Ascend-PPP-VJ-Slot-Comp 210 integer
-ATTRIBUTE Ascend-PPP-VJ-1172 211 integer
-ATTRIBUTE Ascend-PPP-Async-Map 212 integer
-ATTRIBUTE Ascend-Third-Prompt 213 string
-ATTRIBUTE Ascend-Send-Secret 214 string encrypt=3
-ATTRIBUTE Ascend-Receive-Secret 215 string encrypt=3
-ATTRIBUTE Ascend-IPX-Peer-Mode 216 integer
-ATTRIBUTE Ascend-IP-Pool-Definition 217 string
-ATTRIBUTE Ascend-Assign-IP-Pool 218 integer
-ATTRIBUTE Ascend-FR-Direct 219 integer
-ATTRIBUTE Ascend-FR-Direct-Profile 220 string
-ATTRIBUTE Ascend-FR-Direct-DLCI 221 integer
-ATTRIBUTE Ascend-Handle-IPX 222 integer
-ATTRIBUTE Ascend-Netware-timeout 223 integer
-ATTRIBUTE Ascend-IPX-Alias 224 integer
-ATTRIBUTE Ascend-Metric 225 integer
-ATTRIBUTE Ascend-PRI-Number-Type 226 integer
-ATTRIBUTE Ascend-Dial-Number 227 string
-ATTRIBUTE Ascend-Route-IP 228 integer
-ATTRIBUTE Ascend-Route-IPX 229 integer
-ATTRIBUTE Ascend-Bridge 230 integer
-ATTRIBUTE Ascend-Send-Auth 231 integer
-ATTRIBUTE Ascend-Send-Passwd 232 string
-ATTRIBUTE Ascend-Link-Compression 233 integer
-ATTRIBUTE Ascend-Target-Util 234 integer
-ATTRIBUTE Ascend-Maximum-Channels 235 integer
-ATTRIBUTE Ascend-Inc-Channel-Count 236 integer
-ATTRIBUTE Ascend-Dec-Channel-Count 237 integer
-ATTRIBUTE Ascend-Seconds-Of-History 238 integer
-ATTRIBUTE Ascend-History-Weigh-Type 239 integer
-ATTRIBUTE Ascend-Add-Seconds 240 integer
-ATTRIBUTE Ascend-Remove-Seconds 241 integer
-ATTRIBUTE Ascend-Data-Filter 242 abinary
-ATTRIBUTE Ascend-Call-Filter 243 abinary
-ATTRIBUTE Ascend-Idle-Limit 244 integer
-ATTRIBUTE Ascend-Preempt-Limit 245 integer
-ATTRIBUTE Ascend-Callback 246 integer
-ATTRIBUTE Ascend-Data-Svc 247 integer
-ATTRIBUTE Ascend-Force-56 248 integer
-ATTRIBUTE Ascend-Billing-Number 249 string
-ATTRIBUTE Ascend-Call-By-Call 250 integer
-ATTRIBUTE Ascend-Transit-Number 251 string
-ATTRIBUTE Ascend-Host-Info 252 string
-ATTRIBUTE Ascend-PPP-Address 253 ipaddr
-ATTRIBUTE Ascend-MPP-Idle-Percent 254 integer
-ATTRIBUTE Ascend-Xmit-Rate 255 integer
-
-
-# Ascend protocols
-VALUE Service-Type Dialout-Framed-User 5
-VALUE Framed-Protocol Ascend-ARA 255
-VALUE Framed-Protocol Ascend-MPP 256
-VALUE Framed-Protocol Ascend-EURAW 257
-VALUE Framed-Protocol Ascend-EUUI 258
-VALUE Framed-Protocol Ascend-X25 259
-VALUE Framed-Protocol Ascend-COMB 260
-VALUE Framed-Protocol Ascend-FR 261
-VALUE Framed-Protocol Ascend-MP 262
-VALUE Framed-Protocol Ascend-FR-CIR 263
-
-
+# Do NOT edit the following VALUEs! Instead, re-generate them via:
#
-# Ascend specific extensions
-# Used by ASCEND MAX/Pipeline products (see above)
+# (for x in `egrep ^ATTRIBUTE dictionary.ascend | egrep 'X-Ascend-' | awk '{print $2}' | uniq`;do y=`echo $x | sed 's/X-//'`;egrep VALUE dictionary.ascend | egrep $y[^-] | sed "s/$y/X-$y/" ; done) > new-value
#
-
-VALUE Ascend-Source-IP-Check Source-IP-Check-No 0
-VALUE Ascend-Source-IP-Check Source-IP-Check-Yes 1
-VALUE Ascend-CBCP-Enable CBCP-Not-Enabled 0
-VALUE Ascend-CBCP-Enable CBCP-Enabled 1
-VALUE Ascend-CBCP-Mode CBCP-No-Callback 1
-VALUE Ascend-CBCP-Mode CBCP-User-Callback 2
-VALUE Ascend-CBCP-Mode CBCP-Profile-Callback 3
-VALUE Ascend-CBCP-Mode CBCP-Any-Or-No 7
-VALUE Ascend-CBCP-Mode CBCP-Off 8
-VALUE Ascend-FR-Direct FR-Direct-No 0
-VALUE Ascend-FR-Direct FR-Direct-Yes 1
-VALUE Ascend-Handle-IPX Handle-IPX-None 0
-VALUE Ascend-Handle-IPX Handle-IPX-Client 1
-VALUE Ascend-Handle-IPX Handle-IPX-Server 2
-VALUE Ascend-IPX-Peer-Mode IPX-Peer-Router 0
-VALUE Ascend-IPX-Peer-Mode IPX-Peer-Dialin 1
-VALUE Ascend-Call-Type Switched 0
-VALUE Ascend-Call-Type Nailed 1
-VALUE Ascend-Call-Type Nailed/Mpp 2
-VALUE Ascend-Call-Type Perm/Switched 3
-VALUE Ascend-Call-Type AO/DI 6
-VALUE Ascend-Call-Type MegaMax 7
-VALUE Ascend-FT1-Caller FT1-No 0
-VALUE Ascend-FT1-Caller FT1-Yes 1
-VALUE Ascend-PRI-Number-Type Unknown-Number 0
-VALUE Ascend-PRI-Number-Type Intl-Number 1
-VALUE Ascend-PRI-Number-Type National-Number 2
-VALUE Ascend-PRI-Number-Type Net-Specific-Number 3
-VALUE Ascend-PRI-Number-Type Local-Number 4
-VALUE Ascend-PRI-Number-Type Abbrev-Number 5
-
-VALUE Ascend-Route-IP Route-IP-No 0
-VALUE Ascend-Route-IP Route-IP-Yes 1
-VALUE Ascend-Route-IPX Route-IPX-No 0
-VALUE Ascend-Route-IPX Route-IPX-Yes 1
-VALUE Ascend-Bridge Bridge-No 0
-VALUE Ascend-Bridge Bridge-Yes 1
-VALUE Ascend-TS-Idle-Mode TS-Idle-None 0
-VALUE Ascend-TS-Idle-Mode TS-Idle-Input 1
-VALUE Ascend-TS-Idle-Mode TS-Idle-Input-Output 2
-VALUE Ascend-Send-Auth Send-Auth-None 0
-VALUE Ascend-Send-Auth Send-Auth-PAP 1
-VALUE Ascend-Send-Auth Send-Auth-CHAP 2
-VALUE Ascend-Send-Auth Send-Auth-MS-CHAP 3
-VALUE Ascend-Link-Compression Link-Comp-None 0
-VALUE Ascend-Link-Compression Link-Comp-Stac 1
-VALUE Ascend-Link-Compression Link-Comp-Stac-Draft-9 2
-VALUE Ascend-Link-Compression Link-Comp-MS-Stac 3
-VALUE Ascend-History-Weigh-Type History-Constant 0
-VALUE Ascend-History-Weigh-Type History-Linear 1
-VALUE Ascend-History-Weigh-Type History-Quadratic 2
-VALUE Ascend-Callback Callback-No 0
-VALUE Ascend-Callback Callback-Yes 1
-VALUE Ascend-Expect-Callback Expect-Callback-No 0
-VALUE Ascend-Expect-Callback Expect-Callback-Yes 1
-VALUE Ascend-Data-Svc Switched-Voice-Bearer 0
-VALUE Ascend-Data-Svc Nailed-56KR 1
-VALUE Ascend-Data-Svc Nailed-64K 2
-VALUE Ascend-Data-Svc Switched-64KR 3
-VALUE Ascend-Data-Svc Switched-56K 4
-VALUE Ascend-Data-Svc Switched-384KR 5
-VALUE Ascend-Data-Svc Switched-384K 6
-VALUE Ascend-Data-Svc Switched-1536K 7
-VALUE Ascend-Data-Svc Switched-1536KR 8
-VALUE Ascend-Data-Svc Switched-128K 9
-VALUE Ascend-Data-Svc Switched-192K 10
-VALUE Ascend-Data-Svc Switched-256K 11
-VALUE Ascend-Data-Svc Switched-320K 12
-VALUE Ascend-Data-Svc Switched-384K-MR 13
-VALUE Ascend-Data-Svc Switched-448K 14
-VALUE Ascend-Data-Svc Switched-512K 15
-VALUE Ascend-Data-Svc Switched-576K 16
-VALUE Ascend-Data-Svc Switched-640K 17
-VALUE Ascend-Data-Svc Switched-704K 18
-VALUE Ascend-Data-Svc Switched-768K 19
-VALUE Ascend-Data-Svc Switched-832K 20
-VALUE Ascend-Data-Svc Switched-896K 21
-VALUE Ascend-Data-Svc Switched-960K 22
-VALUE Ascend-Data-Svc Switched-1024K 23
-VALUE Ascend-Data-Svc Switched-1088K 24
-VALUE Ascend-Data-Svc Switched-1152K 25
-VALUE Ascend-Data-Svc Switched-1216K 26
-VALUE Ascend-Data-Svc Switched-1280K 27
-VALUE Ascend-Data-Svc Switched-1344K 28
-VALUE Ascend-Data-Svc Switched-1408K 29
-VALUE Ascend-Data-Svc Switched-1472K 30
-VALUE Ascend-Data-Svc Switched-1600K 31
-VALUE Ascend-Data-Svc Switched-1664K 32
-VALUE Ascend-Data-Svc Switched-1728K 33
-VALUE Ascend-Data-Svc Switched-1792K 34
-VALUE Ascend-Data-Svc Switched-1856K 35
-VALUE Ascend-Data-Svc Switched-1920K 36
-VALUE Ascend-Data-Svc Switched-inherited 37
-VALUE Ascend-Data-Svc Switched-restricted-bearer-x30 38
-VALUE Ascend-Data-Svc Switched-clear-bearer-v110 39
-VALUE Ascend-Data-Svc Switched-restricted-64-x30 40
-VALUE Ascend-Data-Svc Switched-clear-56-v110 41
-VALUE Ascend-Data-Svc Switched-modem 42
-VALUE Ascend-Data-Svc Switched-atmodem 43
-VALUE Ascend-Data-Svc Switched-V110-24-56 45
-VALUE Ascend-Data-Svc Switched-V110-48-56 46
-VALUE Ascend-Data-Svc Switched-V110-96-56 47
-VALUE Ascend-Data-Svc Switched-V110-192-56 48
-VALUE Ascend-Data-Svc Switched-V110-384-56 49
-VALUE Ascend-Data-Svc Switched-V110-24-56R 50
-VALUE Ascend-Data-Svc Switched-V110-48-56R 51
-VALUE Ascend-Data-Svc Switched-V110-96-56R 52
-VALUE Ascend-Data-Svc Switched-V110-192-56R 53
-VALUE Ascend-Data-Svc Switched-V110-384-56R 54
-VALUE Ascend-Data-Svc Switched-V110-24-64 55
-VALUE Ascend-Data-Svc Switched-V110-48-64 56
-VALUE Ascend-Data-Svc Switched-V110-96-64 57
-VALUE Ascend-Data-Svc Switched-V110-192-64 58
-VALUE Ascend-Data-Svc Switched-V110-384-64 59
-VALUE Ascend-Data-Svc Switched-V110-24-64R 60
-VALUE Ascend-Data-Svc Switched-V110-48-64R 61
-VALUE Ascend-Data-Svc Switched-V110-96-64R 62
-VALUE Ascend-Data-Svc Switched-V110-384-64R 64
-VALUE Ascend-Data-Svc Switched-V110-192-64R 63
-
-VALUE Ascend-Data-Svc Switched-Pots 68
-VALUE Ascend-Data-Svc Switched-ATM 69
-VALUE Ascend-Data-Svc Switched-FR 70
-
-VALUE Ascend-Force-56 Force-56-No 0
-VALUE Ascend-Force-56 Force-56-Yes 1
-VALUE Ascend-PW-Lifetime Lifetime-In-Days 0
-VALUE Ascend-PW-Warntime Days-Of-Warning 0
-VALUE Ascend-PPP-VJ-1172 PPP-VJ-1172 1
-VALUE Ascend-PPP-VJ-Slot-Comp VJ-Slot-Comp-No 1
-VALUE Ascend-Require-Auth Not-Require-Auth 0
-VALUE Ascend-Require-Auth Require-Auth 1
-VALUE Ascend-Token-Immediate Tok-Imm-No 0
-VALUE Ascend-Token-Immediate Tok-Imm-Yes 1
-VALUE Ascend-DBA-Monitor DBA-Transmit 0
-VALUE Ascend-DBA-Monitor DBA-Transmit-Recv 1
-VALUE Ascend-DBA-Monitor DBA-None 2
-VALUE Ascend-FR-Type Ascend-FR-DTE 0
-VALUE Ascend-FR-Type Ascend-FR-DCE 1
-VALUE Ascend-FR-Type Ascend-FR-NNI 2
-VALUE Ascend-FR-Link-Mgt Ascend-FR-No-Link-Mgt 0
-VALUE Ascend-FR-Link-Mgt Ascend-FR-T1-617D 1
-VALUE Ascend-FR-Link-Mgt Ascend-FR-Q-933A 2
-VALUE Ascend-FR-LinkUp Ascend-LinkUp-Default 0
-VALUE Ascend-FR-LinkUp Ascend-LinkUp-AlwaysUp 1
-VALUE Ascend-Multicast-Client Multicast-No 0
-VALUE Ascend-Multicast-Client Multicast-Yes 1
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-None 0
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-User 1
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-User-Default 2
-VALUE Ascend-User-Acct-Base Base-10 0
-VALUE Ascend-User-Acct-Base Base-16 1
-VALUE Ascend-DHCP-Reply DHCP-Reply-No 0
-VALUE Ascend-DHCP-Reply DHCP-Reply-Yes 1
-VALUE Ascend-Client-Assign-DNS DNS-Assign-No 0
-VALUE Ascend-Client-Assign-DNS DNS-Assign-Yes 1
-VALUE Ascend-Event-Type Ascend-ColdStart 1
-VALUE Ascend-Event-Type Ascend-Session-Event 2
-VALUE Ascend-BACP-Enable BACP-No 0
-VALUE Ascend-BACP-Enable BACP-Yes 1
-VALUE Ascend-Dialout-Allowed Dialout-Not-Allowed 0
-VALUE Ascend-Dialout-Allowed Dialout-Allowed 1
-VALUE Ascend-Shared-Profile-Enable Shared-Profile-No 0
-VALUE Ascend-Shared-Profile-Enable Shared-Profile-Yes 1
-VALUE Ascend-Temporary-Rtes Temp-Rtes-No 0
-VALUE Ascend-Temporary-Rtes Temp-Rtes-Yes 1
-
-# Ascend Disconnect Cause Values
-
-VALUE Ascend-Disconnect-Cause No-Reason 0
-VALUE Ascend-Disconnect-Cause Not-Applicable 1
-VALUE Ascend-Disconnect-Cause Unknown 2
-VALUE Ascend-Disconnect-Cause Call-Disconnected 3
-VALUE Ascend-Disconnect-Cause CLID-Authentication-Failed 4
-VALUE Ascend-Disconnect-Cause CLID-RADIUS-Timeout 5
-
-VALUE Ascend-Disconnect-Cause Modem-No-DCD 10
-VALUE Ascend-Disconnect-Cause DCD-Detected-Then-Inactive 11
-VALUE Ascend-Disconnect-Cause Modem-Invalid-Result-Codes 12
-
-VALUE Ascend-Disconnect-Cause TermSrv-User-Quit 20
-VALUE Ascend-Disconnect-Cause TermSrv-Idle-Timeout 21
-VALUE Ascend-Disconnect-Cause TermSrv-Exit-Telnet 22
-VALUE Ascend-Disconnect-Cause TermSrv-No-IPaddr 23
-VALUE Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP 24
-VALUE Ascend-Disconnect-Cause TermSrv-Exit-Login-Failed 25
-VALUE Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP-Disabled 26
-VALUE Ascend-Disconnect-Cause TermSrv-CTRL-C-In-Login 27
-VALUE Ascend-Disconnect-Cause TermSrv-Destroyed 28
-VALUE Ascend-Disconnect-Cause TermSrv-User-Closed-VCon 29
-
-VALUE Ascend-Disconnect-Cause TermSrv-VCon-Destroyed 30
-VALUE Ascend-Disconnect-Cause TermSrv-Exit-Rlogin 31
-VALUE Ascend-Disconnect-Cause TermSrv-Bad-Rlogin-Option 32
-VALUE Ascend-Disconnect-Cause TermSrv-Not-Enough-Resources 33
-
-VALUE Ascend-Disconnect-Cause MPP-No-NULL-Msg-Timeout 35
-
-VALUE Ascend-Disconnect-Cause PPP-LCP-Timeout 40
-VALUE Ascend-Disconnect-Cause PPP-LCP-Negotion-Failed 41
-VALUE Ascend-Disconnect-Cause PPP-PAP-Auth-Failed 42
-VALUE Ascend-Disconnect-Cause PPP-CHAP-Auth-Failed 43
-VALUE Ascend-Disconnect-Cause PPP-Rmt-Auth-Failed 44
-VALUE Ascend-Disconnect-Cause PPP-Rcv-Terminate-Req 45
-VALUE Ascend-Disconnect-Cause PPP-Rcv-Close-Event 46
-VALUE Ascend-Disconnect-Cause PPP-No-NCPs-Open 47
-VALUE Ascend-Disconnect-Cause PPP-MP-Bundle-Unknown 48
-VALUE Ascend-Disconnect-Cause PPP-LCP-Close-MP-Add-Fail 49
-
-VALUE Ascend-Disconnect-Cause Session-Table-Full 50
-VALUE Ascend-Disconnect-Cause Out-Of-Resources 51
-VALUE Ascend-Disconnect-Cause Invalid-IP-Address 52
-VALUE Ascend-Disconnect-Cause Hostname-Resolution-Failed 53
-VALUE Ascend-Disconnect-Cause Bad-Or-Missing-Port-Number 54
-
-VALUE Ascend-Disconnect-Cause Host-Reset 60
-VALUE Ascend-Disconnect-Cause Connection-Refused 61
-VALUE Ascend-Disconnect-Cause Connection-Timeout 62
-VALUE Ascend-Disconnect-Cause Connection-Closed 63
-VALUE Ascend-Disconnect-Cause Network-Unreachable 64
-VALUE Ascend-Disconnect-Cause Host-Unreachable 65
-VALUE Ascend-Disconnect-Cause Network-Unreachable-Admin 66
-VALUE Ascend-Disconnect-Cause Host-Unreachable-Admin 67
-VALUE Ascend-Disconnect-Cause Port-Unreachable 68
-
-VALUE Ascend-Disconnect-Cause Session-Timeout 100
-VALUE Ascend-Disconnect-Cause Invalid-Incoming-User 101
-VALUE Ascend-Disconnect-Cause Disconnect-Due-To-Callback 102
-
-VALUE Ascend-Disconnect-Cause Proto-Disabled-Or-Unsupported 120
-
-VALUE Ascend-Disconnect-Cause Disconnect-Req-By-RADIUS 150
-VALUE Ascend-Disconnect-Cause Disconnect-Req-By-Local-Admin 151
-
-VALUE Ascend-Disconnect-Cause V110-Timeout-Sync-Retry-Exceed 160
-
-VALUE Ascend-Disconnect-Cause PPP-Auth-Timeout-Exceeded 170
-VALUE Ascend-Disconnect-Cause User-Executed-Do-Hangup 180
-VALUE Ascend-Disconnect-Cause Remote-End-Hung-Up 185
-VALUE Ascend-Disconnect-Cause Resource-Has-Been-Quiesced 190
-VALUE Ascend-Disconnect-Cause Max-Call-Duration-Reached 195
-
-# ascend connect progress codes
-VALUE Ascend-Connect-Progress No-Progress 0
-VALUE Ascend-Connect-Progress Call-Up 10
-VALUE Ascend-Connect-Progress Modem-Up 30
-VALUE Ascend-Connect-Progress Modem-Awaiting-DCD 31
-VALUE Ascend-Connect-Progress Modem-Awaiting-Codes 32
-VALUE Ascend-Connect-Progress TermSrv-Started 40
-VALUE Ascend-Connect-Progress TermSrv-Raw-TCP-Started 41
-VALUE Ascend-Connect-Progress TermSrv-Telnet-Started 42
-VALUE Ascend-Connect-Progress TermSrv-Raw-TCP-Connected 43
-VALUE Ascend-Connect-Progress TermSrv-Telnet-Connected 44
-VALUE Ascend-Connect-Progress TermSrv-Rlogin-Started 45
-VALUE Ascend-Connect-Progress TermSrv-Rlogin-Connected 46
-VALUE Ascend-Connect-Progress Modem-Outdial-Call-Up 50
-VALUE Ascend-Connect-Progress LAN-Session-Up 60
-VALUE Ascend-Connect-Progress LCP-Opening 61
-VALUE Ascend-Connect-Progress CCP-Opening 62
-VALUE Ascend-Connect-Progress IPNCP-Opening 63
-VALUE Ascend-Connect-Progress BNCP-Opening 64
-VALUE Ascend-Connect-Progress LCP-Opened 65
-VALUE Ascend-Connect-Progress CCP-Opened 66
-VALUE Ascend-Connect-Progress IPNCP-Opened 67
-VALUE Ascend-Connect-Progress BNCP-Opened 68
-VALUE Ascend-Connect-Progress LCP-State-Initial 69
-VALUE Ascend-Connect-Progress LCP-State-Starting 70
-VALUE Ascend-Connect-Progress LCP-State-Closed 71
-VALUE Ascend-Connect-Progress LCP-State-Stopped 72
-VALUE Ascend-Connect-Progress LCP-State-Closing 73
-VALUE Ascend-Connect-Progress LCP-State-Stopping 74
-VALUE Ascend-Connect-Progress LCP-State-Request-Sent 75
-VALUE Ascend-Connect-Progress LCP-State-Ack-Received 76
-VALUE Ascend-Connect-Progress LCP-State-Ack-Sent 77
-VALUE Ascend-Connect-Progress IPXNCP-Opened 80
-VALUE Ascend-Connect-Progress ATNCP-Opened 81
-VALUE Ascend-Connect-Progress BACP-Opening 82
-VALUE Ascend-Connect-Progress BACP-Opened 83
-VALUE Ascend-Connect-Progress V110-Up 90
-VALUE Ascend-Connect-Progress V110-State-Opened 91
-VALUE Ascend-Connect-Progress V110-State-Carrier 92
-VALUE Ascend-Connect-Progress V110-State-Reset 93
-VALUE Ascend-Connect-Progress V110-State-Closed 94
-VALUE Ascend-ATM-Direct ATM-Direct-No 0
-VALUE Ascend-ATM-Direct ATM-Direct-Yes 1
-VALUE Ascend-ATM-Fault-Management VC-End-To-End-Loopback 2
-VALUE Ascend-ATM-Fault-Management VC-No-Loopback 0
-VALUE Ascend-ATM-Fault-Management VC-Segment-Loopback 1
-VALUE Ascend-Appletalk-Peer-Mode Appletalk-Peer-Dialin 1
-VALUE Ascend-Appletalk-Peer-Mode Appletalk-Peer-Router 0
-VALUE Ascend-Auth-Type Auth-Any 2
-VALUE Ascend-Auth-Type Auth-CHAP 4
-VALUE Ascend-Auth-Type Auth-Default 1
-VALUE Ascend-Auth-Type Auth-MS-CHAP 5
-VALUE Ascend-Auth-Type Auth-None 0
-VALUE Ascend-Auth-Type Auth-PAP 3
-VALUE Ascend-BIR-Enable BIR-Enable-No 0
-VALUE Ascend-BIR-Enable BIR-Enable-Yes 1
-VALUE Ascend-BIR-Proxy BIR-Proxy-No 0
-VALUE Ascend-BIR-Proxy BIR-Proxy-Yes 1
-VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-Allowed 1
-VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-None 0
-VALUE Ascend-Bi-Directional-Auth Bi-Directional-Auth-Required 2
-VALUE Ascend-Bridge-Non-PPPoE Bridge-Non-PPPoE-No 0
-VALUE Ascend-Bridge-Non-PPPoE Bridge-Non-PPPoE-Yes 1
-VALUE Ascend-Cache-Refresh Refresh-No 0
-VALUE Ascend-Cache-Refresh Refresh-Yes 1
-VALUE Ascend-Call-Direction Ascend-Call-Direction-Incoming 0
-VALUE Ascend-Call-Direction Ascend-Call-Direction-Outgoing 1
-VALUE Ascend-Calling-Id-Number-Plan Data 3
-VALUE Ascend-Calling-Id-Number-Plan ISDN-Telephony 1
-VALUE Ascend-Calling-Id-Number-Plan National 8
-VALUE Ascend-Calling-Id-Number-Plan Private 9
-VALUE Ascend-Calling-Id-Number-Plan Telex 4
-VALUE Ascend-Calling-Id-Number-Plan Unknown 0
-VALUE Ascend-Calling-Id-Presentatn Allowed 0
-VALUE Ascend-Calling-Id-Presentatn Number-Not-Available 2
-VALUE Ascend-Calling-Id-Presentatn Restricted 1
-VALUE Ascend-Calling-Id-Screening Network-Provided 3
-VALUE Ascend-Calling-Id-Screening User-Not-Screened 0
-VALUE Ascend-Calling-Id-Screening User-Provided-Failed 2
-VALUE Ascend-Calling-Id-Screening User-Provided-Passed 1
-VALUE Ascend-Calling-Id-Type-Of-Num Abbreviated-Number 6
-VALUE Ascend-Calling-Id-Type-Of-Num International-Number 1
-VALUE Ascend-Calling-Id-Type-Of-Num National-Number 2
-VALUE Ascend-Calling-Id-Type-Of-Num Network-Specific 3
-VALUE Ascend-Calling-Id-Type-Of-Num Subscriber-Number 4
-VALUE Ascend-Calling-Id-Type-Of-Num Unknown 0
-VALUE Ascend-Ckt-Type Ascend-PVC 0
-VALUE Ascend-Ckt-Type Ascend-SVC 1
-VALUE Ascend-Client-Assign-WINS WINS-Assign-No 0
-VALUE Ascend-Client-Assign-WINS WINS-Assign-Yes 1
-
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1280000 10
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1600000 9
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-1920000 8
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2240000 7
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2560000 6
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-2688000 5
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-3200000 4
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-4480000 3
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-5120000 2
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-6272000 1
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-640000 12
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-7168000 0
-VALUE Ascend-Dsl-Downstream-Limit adslcap-dn-960000 11
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-128000 121
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1280000 114
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1600000 113
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-1920000 112
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2240000 111
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-256000 120
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2560000 110
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-2688000 109
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-3200000 108
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-384000 119
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-4480000 107
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-512000 118
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-5120000 106
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-6272000 105
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-640000 117
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-7168000 104
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-768000 116
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-8000000 103
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-8960000 102
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-9504000 101
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-960000 115
-VALUE Ascend-Dsl-Downstream-Limit adsldmt-dn-auto 100
-VALUE Ascend-Dsl-Rate-Mode Rate-Mode-AutoBaud 1
-VALUE Ascend-Dsl-Rate-Mode Rate-Mode-Single 2
-VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslCap 2
-VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslDmt 4
-VALUE Ascend-Dsl-Rate-Type Rate-Type-AdslDmtCell 3
-VALUE Ascend-Dsl-Rate-Type Rate-Type-Disabled 0
-VALUE Ascend-Dsl-Rate-Type Rate-Type-Sdsl 1
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-896000 153
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-1088000 50
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-272000 56
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-408000 55
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-544000 54
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-680000 53
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-816000 52
-VALUE Ascend-Dsl-Upstream-Limit adslcap-up-952000 51
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-1088000 151
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-128000 160
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-256000 159
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-384000 158
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-512000 157
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-640000 156
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-768000 155
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-800000 154
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-928000 152
-VALUE Ascend-Dsl-Upstream-Limit adsldmt-up-auto 150
-VALUE Ascend-Dsl-Upstream-Limit sdsl-1168000 5
-VALUE Ascend-Dsl-Upstream-Limit sdsl-144000 0
-VALUE Ascend-Dsl-Upstream-Limit sdsl-1552000 6
-VALUE Ascend-Dsl-Upstream-Limit sdsl-2320000 7
-VALUE Ascend-Dsl-Upstream-Limit sdsl-272000 1
-VALUE Ascend-Dsl-Upstream-Limit sdsl-400000 2
-VALUE Ascend-Dsl-Upstream-Limit sdsl-528000 3
-VALUE Ascend-Dsl-Upstream-Limit sdsl-784000 4
-VALUE Ascend-FR-Link-Status-Dlci Ascend-FR-LMI-Dlci-0 0
-VALUE Ascend-FR-Link-Status-Dlci Ascend-FR-LMI-Dlci-1023 1023
-VALUE Ascend-Filter-Required Required-No 0
-VALUE Ascend-Filter-Required Required-Yes 1
-VALUE Ascend-IP-Pool-Chaining IP-Pool-Chaining-No 0
-VALUE Ascend-IP-Pool-Chaining IP-Pool-Chaining-Yes 1
-VALUE Ascend-IP-TOS IP-TOS-Cost 2
-VALUE Ascend-IP-TOS IP-TOS-Disabled 1
-VALUE Ascend-IP-TOS IP-TOS-Latency 16
-VALUE Ascend-IP-TOS IP-TOS-Normal 0
-VALUE Ascend-IP-TOS IP-TOS-Reliability 4
-VALUE Ascend-IP-TOS IP-TOS-Throughput 8
-VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Both 3072
-VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Incoming 1024
-VALUE Ascend-IP-TOS-Apply-To IP-TOS-Apply-To-Outgoing 2048
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Five 160
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Four 128
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Normal 0
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-One 32
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Seven 224
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Six 192
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Three 96
-VALUE Ascend-IP-TOS-Precedence IP-TOS-Precedence-Pri-Two 64
-VALUE Ascend-IPX-Header-Compression IPX-Header-Compression-No 0
-VALUE Ascend-IPX-Header-Compression IPX-Header-Compression-Yes 1
-VALUE Ascend-NAS-Port-Format 1_2_2 3
-VALUE Ascend-NAS-Port-Format 2_4_5_5 2
-VALUE Ascend-NAS-Port-Format 2_4_6_4 1
-VALUE Ascend-NAS-Port-Format Unknown 0
-VALUE Ascend-Numbering-Plan-ID ISDN-Numbering-Plan 1
-VALUE Ascend-Numbering-Plan-ID Private-Numbering-Plan 9
-VALUE Ascend-Numbering-Plan-ID Unknown-Numbering-Plan 0
-VALUE Ascend-PPPoE-Enable PPPoE-No 0
-VALUE Ascend-PPPoE-Enable PPPoE-Yes 1
-VALUE Ascend-PW-Lifetime Lifetime-In-Days 0
-VALUE Ascend-PW-Warntime Days-Of-Warning 0
-VALUE Ascend-Port-Redir-Protocol Ascend-Proto-TCP 6
-VALUE Ascend-Port-Redir-Protocol Ascend-Proto-UDP 17
-VALUE Ascend-Private-Route-Required Required-No 0
-VALUE Ascend-Private-Route-Required Required-Yes 1
-VALUE Ascend-Require-Auth Not-Require-Auth 0
-VALUE Ascend-Require-Auth Require-Auth 1
-VALUE Ascend-Route-Appletalk Route-Appletalk-No 0
-VALUE Ascend-Route-Appletalk Route-Appletalk-Yes 1
-VALUE Ascend-Route-IP Route-IP-No 0
-VALUE Ascend-Route-IP Route-IP-Yes 1
-VALUE Ascend-Route-IPX Route-IPX-No 0
-VALUE Ascend-Route-IPX Route-IPX-Yes 1
-VALUE Ascend-SVC-Enabled Ascend-SVC-Enabled-No 0
-VALUE Ascend-SVC-Enabled Ascend-SVC-Enabled-Yes 1
-VALUE Ascend-Send-Auth Send-Auth-CHAP 2
-VALUE Ascend-Send-Auth Send-Auth-MS-CHAP 3
-VALUE Ascend-Send-Auth Send-Auth-None 0
-VALUE Ascend-Send-Auth Send-Auth-PAP 1
-VALUE Ascend-Service-Type Ascend-Service-Type-ATM 20
-VALUE Ascend-Service-Type Ascend-Service-Type-Combinet 7
-VALUE Ascend-Service-Type Ascend-Service-Type-EuRaw 9
-VALUE Ascend-Service-Type Ascend-Service-Type-EuUi 10
-VALUE Ascend-Service-Type Ascend-Service-Type-FR 8
-VALUE Ascend-Service-Type Ascend-Service-Type-HdlcNrm 21
-VALUE Ascend-Service-Type Ascend-Service-Type-IpFax 19
-VALUE Ascend-Service-Type Ascend-Service-Type-MP 15
-VALUE Ascend-Service-Type Ascend-Service-Type-MPP 5
-VALUE Ascend-Service-Type Ascend-Service-Type-NetToNet 25
-VALUE Ascend-Service-Type Ascend-Service-Type-None 1
-VALUE Ascend-Service-Type Ascend-Service-Type-NotUsed 0
-VALUE Ascend-Service-Type Ascend-Service-Type-Other 2
-VALUE Ascend-Service-Type Ascend-Service-Type-PPP 3
-VALUE Ascend-Service-Type Ascend-Service-Type-PseuTunPPP 18
-VALUE Ascend-Service-Type Ascend-Service-Type-RawTcp 13
-VALUE Ascend-Service-Type Ascend-Service-Type-Slip 4
-VALUE Ascend-Service-Type Ascend-Service-Type-Telnet 11
-VALUE Ascend-Service-Type Ascend-Service-Type-TelnetBin 12
-VALUE Ascend-Service-Type Ascend-Service-Type-TermServer 14
-VALUE Ascend-Service-Type Ascend-Service-Type-VirtualConn 16
-VALUE Ascend-Service-Type Ascend-Service-Type-Visa2 23
-VALUE Ascend-Service-Type Ascend-Service-Type-VoIp 22
-VALUE Ascend-Service-Type Ascend-Service-Type-X25 6
-VALUE Ascend-Service-Type Ascend-Service-Type-X25DChan 17
-VALUE Ascend-Session-Type Ascend-Session-G711-Alaw 3
-VALUE Ascend-Session-Type Ascend-Session-G711-Ulaw 2
-VALUE Ascend-Session-Type Ascend-Session-G723 4
-VALUE Ascend-Session-Type Ascend-Session-G723-64KPS 6
-VALUE Ascend-Session-Type Ascend-Session-G728 7
-VALUE Ascend-Session-Type Ascend-Session-G729 5
-VALUE Ascend-Session-Type Ascend-Session-RT24 8
-VALUE Ascend-Session-Type Ascend-Session-Unknown 1
-VALUE Ascend-Session-Type Ascend-Session-Unused 0
-VALUE Ascend-Shared-Profile-Enable Shared-Profile-No 0
-VALUE Ascend-Shared-Profile-Enable Shared-Profile-Yes 1
-VALUE Ascend-Source-IP-Check Source-IP-Check-No 0
-VALUE Ascend-Source-IP-Check Source-IP-Check-Yes 1
-VALUE Ascend-TS-Idle-Mode TS-Idle-Input 1
-VALUE Ascend-TS-Idle-Mode TS-Idle-Input-Output 2
-VALUE Ascend-TS-Idle-Mode TS-Idle-None 0
-VALUE Ascend-Token-Immediate Tok-Imm-No 0
-VALUE Ascend-Token-Immediate Tok-Imm-Yes 1
-VALUE Ascend-Tunneling-Protocol ATMP-Tunnel 0
-VALUE Ascend-Tunneling-Protocol VTP-Tunnel 1
-VALUE Ascend-User-Acct-Base Base-10 0
-VALUE Ascend-User-Acct-Base Base-16 1
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-None 0
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-User 1
-VALUE Ascend-User-Acct-Type Ascend-User-Acct-User-Default 2
-VALUE Ascend-X25-Pad-X3-Profile CC_SSP 4
-VALUE Ascend-X25-Pad-X3-Profile CC_TSP 5
-VALUE Ascend-X25-Pad-X3-Profile CRT 0
-VALUE Ascend-X25-Pad-X3-Profile CUSTOM 11
-VALUE Ascend-X25-Pad-X3-Profile DEFAULT 2
-VALUE Ascend-X25-Pad-X3-Profile HARDCOPY 6
-VALUE Ascend-X25-Pad-X3-Profile HDX 7
-VALUE Ascend-X25-Pad-X3-Profile INFONET 1
-VALUE Ascend-X25-Pad-X3-Profile NULL 10
-VALUE Ascend-X25-Pad-X3-Profile POS 9
-VALUE Ascend-X25-Pad-X3-Profile SCEN 3
-VALUE Ascend-X25-Pad-X3-Profile SHARK 8
-VALUE Ascend-X25-Reverse-Charging Reverse-Charging-No 0
-VALUE Ascend-X25-Reverse-Charging Reverse-Charging-Yes 1
-END-VENDOR Ascend
+#
+VALUE X-Ascend-Temporary-Rtes Temp-Rtes-No 0
+VALUE X-Ascend-Temporary-Rtes Temp-Rtes-Yes 1
+VALUE X-Ascend-Tunneling-Protocol ATMP-Tunnel 0
+VALUE X-Ascend-Tunneling-Protocol VTP-Tunnel 1
+VALUE X-Ascend-Shared-Profile-Enable Shared-Profile-No 0
+VALUE X-Ascend-Shared-Profile-Enable Shared-Profile-Yes 1
+VALUE X-Ascend-Dialout-Allowed Dialout-Not-Allowed 0
+VALUE X-Ascend-Dialout-Allowed Dialout-Allowed 1
+VALUE X-Ascend-BACP-Enable BACP-No 0
+VALUE X-Ascend-BACP-Enable BACP-Yes 1
+VALUE X-Ascend-Client-Assign-DNS DNS-Assign-No 0
+VALUE X-Ascend-Client-Assign-DNS DNS-Assign-Yes 1
+VALUE X-Ascend-User-Acct-Type Ascend-User-Acct-None 0
+VALUE X-Ascend-User-Acct-Type Ascend-User-Acct-User 1
+VALUE X-Ascend-User-Acct-Type Ascend-User-Acct-User-Default 2
+VALUE X-Ascend-User-Acct-Base Base-10 0
+VALUE X-Ascend-User-Acct-Base Base-16 1
+VALUE X-Ascend-DHCP-Reply DHCP-Reply-No 0
+VALUE X-Ascend-DHCP-Reply DHCP-Reply-Yes 1
+VALUE X-Ascend-Expect-Callback Expect-Callback-No 0
+VALUE X-Ascend-Expect-Callback Expect-Callback-Yes 1
+VALUE X-Ascend-Event-Type Ascend-ColdStart 1
+VALUE X-Ascend-Event-Type Ascend-Session-Event 2
+VALUE X-Ascend-Multicast-Client Multicast-No 0
+VALUE X-Ascend-Multicast-Client Multicast-Yes 1
+VALUE X-Ascend-FR-LinkUp Ascend-LinkUp-Default 0
+VALUE X-Ascend-FR-LinkUp Ascend-LinkUp-AlwaysUp 1
+VALUE X-Ascend-FR-Type Ascend-FR-DTE 0
+VALUE X-Ascend-FR-Type Ascend-FR-DCE 1
+VALUE X-Ascend-FR-Type Ascend-FR-NNI 2
+VALUE X-Ascend-FR-Link-Mgt Ascend-FR-No-Link-Mgt 0
+VALUE X-Ascend-FR-Link-Mgt Ascend-FR-T1-617D 1
+VALUE X-Ascend-FR-Link-Mgt Ascend-FR-Q-933A 2
+VALUE X-Ascend-TS-Idle-Mode TS-Idle-None 0
+VALUE X-Ascend-TS-Idle-Mode TS-Idle-Input 1
+VALUE X-Ascend-TS-Idle-Mode TS-Idle-Input-Output 2
+VALUE X-Ascend-DBA-Monitor DBA-Transmit 0
+VALUE X-Ascend-DBA-Monitor DBA-Transmit-Recv 1
+VALUE X-Ascend-DBA-Monitor DBA-None 2
+VALUE X-Ascend-FT1-Caller FT1-No 0
+VALUE X-Ascend-FT1-Caller FT1-Yes 1
+VALUE X-Ascend-Call-Type Switched 0
+VALUE X-Ascend-Call-Type Nailed 1
+VALUE X-Ascend-Call-Type Nailed/Mpp 2
+VALUE X-Ascend-Call-Type Perm/Switched 3
+VALUE X-Ascend-Call-Type AO/DI 6
+VALUE X-Ascend-Call-Type MegaMax 7
+VALUE X-Ascend-Disconnect-Cause No-Reason 0
+VALUE X-Ascend-Disconnect-Cause Not-Applicable 1
+VALUE X-Ascend-Disconnect-Cause Unknown 2
+VALUE X-Ascend-Disconnect-Cause Call-Disconnected 3
+VALUE X-Ascend-Disconnect-Cause CLID-Authentication-Failed 4
+VALUE X-Ascend-Disconnect-Cause CLID-RADIUS-Timeout 5
+VALUE X-Ascend-Disconnect-Cause Modem-No-DCD 10
+VALUE X-Ascend-Disconnect-Cause DCD-Detected-Then-Inactive 11
+VALUE X-Ascend-Disconnect-Cause Modem-Invalid-Result-Codes 12
+VALUE X-Ascend-Disconnect-Cause TermSrv-User-Quit 20
+VALUE X-Ascend-Disconnect-Cause TermSrv-Idle-Timeout 21
+VALUE X-Ascend-Disconnect-Cause TermSrv-Exit-Telnet 22
+VALUE X-Ascend-Disconnect-Cause TermSrv-No-IPaddr 23
+VALUE X-Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP 24
+VALUE X-Ascend-Disconnect-Cause TermSrv-Exit-Login-Failed 25
+VALUE X-Ascend-Disconnect-Cause TermSrv-Exit-Raw-TCP-Disabled 26
+VALUE X-Ascend-Disconnect-Cause TermSrv-CTRL-C-In-Login 27
+VALUE X-Ascend-Disconnect-Cause TermSrv-Destroyed 28
+VALUE X-Ascend-Disconnect-Cause TermSrv-User-Closed-VCon 29
+VALUE X-Ascend-Disconnect-Cause TermSrv-VCon-Destroyed 30
+VALUE X-Ascend-Disconnect-Cause TermSrv-Exit-Rlogin 31
+VALUE X-Ascend-Disconnect-Cause TermSrv-Bad-Rlogin-Option 32
+VALUE X-Ascend-Disconnect-Cause TermSrv-Not-Enough-Resources 33
+VALUE X-Ascend-Disconnect-Cause MPP-No-NULL-Msg-Timeout 35
+VALUE X-Ascend-Disconnect-Cause PPP-LCP-Timeout 40
+VALUE X-Ascend-Disconnect-Cause PPP-LCP-Negotion-Failed 41
+VALUE X-Ascend-Disconnect-Cause PPP-PAP-Auth-Failed 42
+VALUE X-Ascend-Disconnect-Cause PPP-CHAP-Auth-Failed 43
+VALUE X-Ascend-Disconnect-Cause PPP-Rmt-Auth-Failed 44
+VALUE X-Ascend-Disconnect-Cause PPP-Rcv-Terminate-Req 45
+VALUE X-Ascend-Disconnect-Cause PPP-Rcv-Close-Event 46
+VALUE X-Ascend-Disconnect-Cause PPP-No-NCPs-Open 47
+VALUE X-Ascend-Disconnect-Cause PPP-MP-Bundle-Unknown 48
+VALUE X-Ascend-Disconnect-Cause PPP-LCP-Close-MP-Add-Fail 49
+VALUE X-Ascend-Disconnect-Cause Session-Table-Full 50
+VALUE X-Ascend-Disconnect-Cause Out-Of-Resources 51
+VALUE X-Ascend-Disconnect-Cause Invalid-IP-Address 52
+VALUE X-Ascend-Disconnect-Cause Hostname-Resolution-Failed 53
+VALUE X-Ascend-Disconnect-Cause Bad-Or-Missing-Port-Number 54
+VALUE X-Ascend-Disconnect-Cause Host-Reset 60
+VALUE X-Ascend-Disconnect-Cause Connection-Refused 61
+VALUE X-Ascend-Disconnect-Cause Connection-Timeout 62
+VALUE X-Ascend-Disconnect-Cause Connection-Closed 63
+VALUE X-Ascend-Disconnect-Cause Network-Unreachable 64
+VALUE X-Ascend-Disconnect-Cause Host-Unreachable 65
+VALUE X-Ascend-Disconnect-Cause Network-Unreachable-Admin 66
+VALUE X-Ascend-Disconnect-Cause Host-Unreachable-Admin 67
+VALUE X-Ascend-Disconnect-Cause Port-Unreachable 68
+VALUE X-Ascend-Disconnect-Cause Session-Timeout 100
+VALUE X-Ascend-Disconnect-Cause Invalid-Incoming-User 101
+VALUE X-Ascend-Disconnect-Cause Disconnect-Due-To-Callback 102
+VALUE X-Ascend-Disconnect-Cause Proto-Disabled-Or-Unsupported 120
+VALUE X-Ascend-Disconnect-Cause Disconnect-Req-By-RADIUS 150
+VALUE X-Ascend-Disconnect-Cause Disconnect-Req-By-Local-Admin 151
+VALUE X-Ascend-Disconnect-Cause V110-Timeout-Sync-Retry-Exceed 160
+VALUE X-Ascend-Disconnect-Cause PPP-Auth-Timeout-Exceeded 170
+VALUE X-Ascend-Disconnect-Cause User-Executed-Do-Hangup 180
+VALUE X-Ascend-Disconnect-Cause Remote-End-Hung-Up 185
+VALUE X-Ascend-Disconnect-Cause Resource-Has-Been-Quiesced 190
+VALUE X-Ascend-Disconnect-Cause Max-Call-Duration-Reached 195
+VALUE X-Ascend-Connect-Progress No-Progress 0
+VALUE X-Ascend-Connect-Progress Call-Up 10
+VALUE X-Ascend-Connect-Progress Modem-Up 30
+VALUE X-Ascend-Connect-Progress Modem-Awaiting-DCD 31
+VALUE X-Ascend-Connect-Progress Modem-Awaiting-Codes 32
+VALUE X-Ascend-Connect-Progress TermSrv-Started 40
+VALUE X-Ascend-Connect-Progress TermSrv-Raw-TCP-Started 41
+VALUE X-Ascend-Connect-Progress TermSrv-Telnet-Started 42
+VALUE X-Ascend-Connect-Progress TermSrv-Raw-TCP-Connected 43
+VALUE X-Ascend-Connect-Progress TermSrv-Telnet-Connected 44
+VALUE X-Ascend-Connect-Progress TermSrv-Rlogin-Started 45
+VALUE X-Ascend-Connect-Progress TermSrv-Rlogin-Connected 46
+VALUE X-Ascend-Connect-Progress Modem-Outdial-Call-Up 50
+VALUE X-Ascend-Connect-Progress LAN-Session-Up 60
+VALUE X-Ascend-Connect-Progress LCP-Opening 61
+VALUE X-Ascend-Connect-Progress CCP-Opening 62
+VALUE X-Ascend-Connect-Progress IPNCP-Opening 63
+VALUE X-Ascend-Connect-Progress BNCP-Opening 64
+VALUE X-Ascend-Connect-Progress LCP-Opened 65
+VALUE X-Ascend-Connect-Progress CCP-Opened 66
+VALUE X-Ascend-Connect-Progress IPNCP-Opened 67
+VALUE X-Ascend-Connect-Progress BNCP-Opened 68
+VALUE X-Ascend-Connect-Progress LCP-State-Initial 69
+VALUE X-Ascend-Connect-Progress LCP-State-Starting 70
+VALUE X-Ascend-Connect-Progress LCP-State-Closed 71
+VALUE X-Ascend-Connect-Progress LCP-State-Stopped 72
+VALUE X-Ascend-Connect-Progress LCP-State-Closing 73
+VALUE X-Ascend-Connect-Progress LCP-State-Stopping 74
+VALUE X-Ascend-Connect-Progress LCP-State-Request-Sent 75
+VALUE X-Ascend-Connect-Progress LCP-State-Ack-Received 76
+VALUE X-Ascend-Connect-Progress LCP-State-Ack-Sent 77
+VALUE X-Ascend-Connect-Progress IPXNCP-Opened 80
+VALUE X-Ascend-Connect-Progress ATNCP-Opened 81
+VALUE X-Ascend-Connect-Progress BACP-Opening 82
+VALUE X-Ascend-Connect-Progress BACP-Opened 83
+VALUE X-Ascend-Connect-Progress V110-Up 90
+VALUE X-Ascend-Connect-Progress V110-State-Opened 91
+VALUE X-Ascend-Connect-Progress V110-State-Carrier 92
+VALUE X-Ascend-Connect-Progress V110-State-Reset 93
+VALUE X-Ascend-Connect-Progress V110-State-Closed 94
+VALUE X-Ascend-Token-Immediate Tok-Imm-No 0
+VALUE X-Ascend-Token-Immediate Tok-Imm-Yes 1
+VALUE X-Ascend-Require-Auth Not-Require-Auth 0
+VALUE X-Ascend-Require-Auth Require-Auth 1
+VALUE X-Ascend-PW-Warntime Days-Of-Warning 0
+VALUE X-Ascend-PW-Lifetime Lifetime-In-Days 0
+VALUE X-Ascend-PPP-VJ-Slot-Comp VJ-Slot-Comp-No 1
+VALUE X-Ascend-PPP-VJ-1172 PPP-VJ-1172 1
+VALUE X-Ascend-IPX-Peer-Mode IPX-Peer-Router 0
+VALUE X-Ascend-IPX-Peer-Mode IPX-Peer-Dialin 1
+VALUE X-Ascend-FR-Direct FR-Direct-No 0
+VALUE X-Ascend-FR-Direct FR-Direct-Yes 1
+VALUE X-Ascend-Handle-IPX Handle-IPX-None 0
+VALUE X-Ascend-Handle-IPX Handle-IPX-Client 1
+VALUE X-Ascend-Handle-IPX Handle-IPX-Server 2
+VALUE X-Ascend-PRI-Number-Type Unknown-Number 0
+VALUE X-Ascend-PRI-Number-Type Intl-Number 1
+VALUE X-Ascend-PRI-Number-Type National-Number 2
+VALUE X-Ascend-PRI-Number-Type Net-Specific-Number 3
+VALUE X-Ascend-PRI-Number-Type Local-Number 4
+VALUE X-Ascend-PRI-Number-Type Abbrev-Number 5
+VALUE X-Ascend-Route-IP Route-IP-No 0
+VALUE X-Ascend-Route-IP Route-IP-Yes 1
+VALUE X-Ascend-Route-IPX Route-IPX-No 0
+VALUE X-Ascend-Route-IPX Route-IPX-Yes 1
+VALUE X-Ascend-Route-IPX Route-IPX-No 0
+VALUE X-Ascend-Route-IPX Route-IPX-Yes 1
+VALUE X-Ascend-Bridge Bridge-No 0
+VALUE X-Ascend-Bridge Bridge-Yes 1
+VALUE X-Ascend-Send-Auth Send-Auth-None 0
+VALUE X-Ascend-Send-Auth Send-Auth-PAP 1
+VALUE X-Ascend-Send-Auth Send-Auth-CHAP 2
+VALUE X-Ascend-Send-Auth Send-Auth-MS-CHAP 3
+VALUE X-Ascend-Link-Compression Link-Comp-None 0
+VALUE X-Ascend-Link-Compression Link-Comp-Stac 1
+VALUE X-Ascend-Link-Compression Link-Comp-Stac-Draft-9 2
+VALUE X-Ascend-Link-Compression Link-Comp-MS-Stac 3
+VALUE X-Ascend-History-Weigh-Type History-Constant 0
+VALUE X-Ascend-History-Weigh-Type History-Linear 1
+VALUE X-Ascend-History-Weigh-Type History-Quadratic 2
+VALUE X-Ascend-Callback Callback-No 0
+VALUE X-Ascend-Callback Callback-Yes 1
+VALUE X-Ascend-Data-Svc Switched-Voice-Bearer 0
+VALUE X-Ascend-Data-Svc Nailed-56KR 1
+VALUE X-Ascend-Data-Svc Nailed-64K 2
+VALUE X-Ascend-Data-Svc Switched-64KR 3
+VALUE X-Ascend-Data-Svc Switched-56K 4
+VALUE X-Ascend-Data-Svc Switched-384KR 5
+VALUE X-Ascend-Data-Svc Switched-384K 6
+VALUE X-Ascend-Data-Svc Switched-1536K 7
+VALUE X-Ascend-Data-Svc Switched-1536KR 8
+VALUE X-Ascend-Data-Svc Switched-128K 9
+VALUE X-Ascend-Data-Svc Switched-192K 10
+VALUE X-Ascend-Data-Svc Switched-256K 11
+VALUE X-Ascend-Data-Svc Switched-320K 12
+VALUE X-Ascend-Data-Svc Switched-384K-MR 13
+VALUE X-Ascend-Data-Svc Switched-448K 14
+VALUE X-Ascend-Data-Svc Switched-512K 15
+VALUE X-Ascend-Data-Svc Switched-576K 16
+VALUE X-Ascend-Data-Svc Switched-640K 17
+VALUE X-Ascend-Data-Svc Switched-704K 18
+VALUE X-Ascend-Data-Svc Switched-768K 19
+VALUE X-Ascend-Data-Svc Switched-832K 20
+VALUE X-Ascend-Data-Svc Switched-896K 21
+VALUE X-Ascend-Data-Svc Switched-960K 22
+VALUE X-Ascend-Data-Svc Switched-1024K 23
+VALUE X-Ascend-Data-Svc Switched-1088K 24
+VALUE X-Ascend-Data-Svc Switched-1152K 25
+VALUE X-Ascend-Data-Svc Switched-1216K 26
+VALUE X-Ascend-Data-Svc Switched-1280K 27
+VALUE X-Ascend-Data-Svc Switched-1344K 28
+VALUE X-Ascend-Data-Svc Switched-1408K 29
+VALUE X-Ascend-Data-Svc Switched-1472K 30
+VALUE X-Ascend-Data-Svc Switched-1600K 31
+VALUE X-Ascend-Data-Svc Switched-1664K 32
+VALUE X-Ascend-Data-Svc Switched-1728K 33
+VALUE X-Ascend-Data-Svc Switched-1792K 34
+VALUE X-Ascend-Data-Svc Switched-1856K 35
+VALUE X-Ascend-Data-Svc Switched-1920K 36
+VALUE X-Ascend-Data-Svc Switched-inherited 37
+VALUE X-Ascend-Data-Svc Switched-restricted-bearer-x30 38
+VALUE X-Ascend-Data-Svc Switched-clear-bearer-v110 39
+VALUE X-Ascend-Data-Svc Switched-restricted-64-x30 40
+VALUE X-Ascend-Data-Svc Switched-clear-56-v110 41
+VALUE X-Ascend-Data-Svc Switched-modem 42
+VALUE X-Ascend-Data-Svc Switched-atmodem 43
+VALUE X-Ascend-Data-Svc Switched-V110-24-56 45
+VALUE X-Ascend-Data-Svc Switched-V110-48-56 46
+VALUE X-Ascend-Data-Svc Switched-V110-96-56 47
+VALUE X-Ascend-Data-Svc Switched-V110-192-56 48
+VALUE X-Ascend-Data-Svc Switched-V110-384-56 49
+VALUE X-Ascend-Data-Svc Switched-V110-24-56R 50
+VALUE X-Ascend-Data-Svc Switched-V110-48-56R 51
+VALUE X-Ascend-Data-Svc Switched-V110-96-56R 52
+VALUE X-Ascend-Data-Svc Switched-V110-192-56R 53
+VALUE X-Ascend-Data-Svc Switched-V110-384-56R 54
+VALUE X-Ascend-Data-Svc Switched-V110-24-64 55
+VALUE X-Ascend-Data-Svc Switched-V110-48-64 56
+VALUE X-Ascend-Data-Svc Switched-V110-96-64 57
+VALUE X-Ascend-Data-Svc Switched-V110-192-64 58
+VALUE X-Ascend-Data-Svc Switched-V110-384-64 59
+VALUE X-Ascend-Data-Svc Switched-V110-24-64R 60
+VALUE X-Ascend-Data-Svc Switched-V110-48-64R 61
+VALUE X-Ascend-Data-Svc Switched-V110-96-64R 62
+VALUE X-Ascend-Data-Svc Switched-V110-384-64R 64
+VALUE X-Ascend-Data-Svc Switched-V110-192-64R 63
+VALUE X-Ascend-Data-Svc Switched-Pots 68
+VALUE X-Ascend-Data-Svc Switched-ATM 69
+VALUE X-Ascend-Data-Svc Switched-FR 70
+VALUE X-Ascend-Force-56 Force-56-No 0
+VALUE X-Ascend-Force-56 Force-56-Yes 1
--- /dev/null
+# -*- text -*-
+#
+# Avaya P330 dictionary file
+# $Id$
+#
+# http://support.avaya.com/elmodocs2/p330/P330/Configuring%20FreeRadius.pdf
+#
+
+VENDOR Cajun_p330 2167
+BEGIN-VENDOR Cajun_p330
+
+ATTRIBUTE Cajun-Service-Type 1 integer
+
+VALUE Cajun-Service-Type Cajun-Read-Only-User 1
+VALUE Cajun-Service-Type Cajun-Read-Write-User 2
+VALUE Cajun-Service-Type Cajun-Admin-User 3
+
+ATTRIBUTE Avaya-StaticVlan-Type 12 string
+ATTRIBUTE Avaya-PortPriority-Type 13 integer
+
+VALUE Avaya-PortPriority-Type Type-0 0
+VALUE Avaya-PortPriority-Type Type-1 1
+VALUE Avaya-PortPriority-Type Type-2 2
+VALUE Avaya-PortPriority-Type Type-3 3
+VALUE Avaya-PortPriority-Type Type-4 4
+VALUE Avaya-PortPriority-Type Type-5 5
+VALUE Avaya-PortPriority-Type Type-6 6
+VALUE Avaya-PortPriority-Type Type-7 7
+
+END-VENDOR Cajun_p330
+# -*- text -*-
#
# Bay Networks
# http://www.baynetworks.com/
# Modified for libradius by Alan DeKok <aland@ox.org>
#
-VENDOR Bay-Networks 1584 # now Nortel
+VENDOR Bay-Networks 1584 # now Nortel
-BEGIN-VENDOR Bay-Networks
+BEGIN-VENDOR Bay-Networks
# Bay Networks Extensions
-ATTRIBUTE Annex-Filter 28 string
-ATTRIBUTE Annex-CLI-Command 29 string
-ATTRIBUTE Annex-CLI-Filter 30 string
-ATTRIBUTE Annex-Host-Restrict 31 string
-ATTRIBUTE Annex-Host-Allow 32 string
-ATTRIBUTE Annex-Product-Name 33 string
-ATTRIBUTE Annex-SW-Version 34 string
-ATTRIBUTE Annex-Local-IP-Address 35 ipaddr
-ATTRIBUTE Annex-Callback-Portlist 36 integer
-ATTRIBUTE Annex-Sec-Profile-Index 37 integer
-ATTRIBUTE Annex-Tunnel-Authen-Type 38 integer
-ATTRIBUTE Annex-Tunnel-Authen-Mode 39 integer
-ATTRIBUTE Annex-Authen-Servers 40 string
-ATTRIBUTE Annex-Acct-Servers 41 string
-ATTRIBUTE Annex-User-Server-Location 42 integer
-ATTRIBUTE Annex-Local-Username 43 string
-ATTRIBUTE Annex-System-Disc-Reason 44 integer
-ATTRIBUTE Annex-Modem-Disc-Reason 45 integer
-ATTRIBUTE Annex-Disconnect-Reason 46 integer
-ATTRIBUTE Annex-Addr-Resolution-Protocol 47 integer
-ATTRIBUTE Annex-Addr-Resolution-Servers 48 string
-ATTRIBUTE Annex-Domain-Name 49 string
-ATTRIBUTE Annex-Transmit-Speed 50 integer
-ATTRIBUTE Annex-Receive-Speed 51 integer
-ATTRIBUTE Annex-Input-Filter 52 string
-ATTRIBUTE Annex-Output-Filter 53 string
-ATTRIBUTE Annex-Primary-DNS-Server 54 ipaddr
-ATTRIBUTE Annex-Secondary-DNS-Server 55 ipaddr
-ATTRIBUTE Annex-Primary-NBNS-Server 56 ipaddr
-ATTRIBUTE Annex-Secondary-NBNS-Server 57 ipaddr
-ATTRIBUTE Annex-Syslog-Tap 58 integer
-ATTRIBUTE Annex-Keypress-Timeout 59 integer
-ATTRIBUTE Annex-Unauthenticated-Time 60 integer
-ATTRIBUTE Annex-Re-CHAP-Timeout 61 integer
-ATTRIBUTE Annex-MRRU 62 integer
-ATTRIBUTE Annex-EDO 63 string
+ATTRIBUTE Annex-Filter 28 string
+ATTRIBUTE Annex-CLI-Command 29 string
+ATTRIBUTE Annex-CLI-Filter 30 string
+ATTRIBUTE Annex-Host-Restrict 31 string
+ATTRIBUTE Annex-Host-Allow 32 string
+ATTRIBUTE Annex-Product-Name 33 string
+ATTRIBUTE Annex-SW-Version 34 string
+ATTRIBUTE Annex-Local-IP-Address 35 ipaddr
+ATTRIBUTE Annex-Callback-Portlist 36 integer
+ATTRIBUTE Annex-Sec-Profile-Index 37 integer
+ATTRIBUTE Annex-Tunnel-Authen-Type 38 integer
+ATTRIBUTE Annex-Tunnel-Authen-Mode 39 integer
+ATTRIBUTE Annex-Authen-Servers 40 string
+ATTRIBUTE Annex-Acct-Servers 41 string
+ATTRIBUTE Annex-User-Server-Location 42 integer
+ATTRIBUTE Annex-Local-Username 43 string
+ATTRIBUTE Annex-System-Disc-Reason 44 integer
+ATTRIBUTE Annex-Modem-Disc-Reason 45 integer
+ATTRIBUTE Annex-Disconnect-Reason 46 integer
+ATTRIBUTE Annex-Addr-Resolution-Protocol 47 integer
+ATTRIBUTE Annex-Addr-Resolution-Servers 48 string
+ATTRIBUTE Annex-Domain-Name 49 string
+ATTRIBUTE Annex-Transmit-Speed 50 integer
+ATTRIBUTE Annex-Receive-Speed 51 integer
+ATTRIBUTE Annex-Input-Filter 52 string
+ATTRIBUTE Annex-Output-Filter 53 string
+ATTRIBUTE Annex-Primary-DNS-Server 54 ipaddr
+ATTRIBUTE Annex-Secondary-DNS-Server 55 ipaddr
+ATTRIBUTE Annex-Primary-NBNS-Server 56 ipaddr
+ATTRIBUTE Annex-Secondary-NBNS-Server 57 ipaddr
+ATTRIBUTE Annex-Syslog-Tap 58 integer
+ATTRIBUTE Annex-Keypress-Timeout 59 integer
+ATTRIBUTE Annex-Unauthenticated-Time 60 integer
+ATTRIBUTE Annex-Re-CHAP-Timeout 61 integer
+ATTRIBUTE Annex-MRRU 62 integer
+ATTRIBUTE Annex-EDO 63 string
# Annex R18.0 software
-ATTRIBUTE Annex-PPP-Trace-Level 64 integer
-ATTRIBUTE Annex-Pre-Input-Octets 65 integer
-ATTRIBUTE Annex-Pre-Output-Octets 66 integer
-ATTRIBUTE Annex-Pre-Input-Packets 67 integer
-ATTRIBUTE Annex-Pre-Output-Packets 68 integer
-ATTRIBUTE Annex-Connect-Progress 69 integer
-ATTRIBUTE Annex-Multicast-Rate-Limit 73 integer
-ATTRIBUTE Annex-Maximum-Call-Duration 74 integer
-ATTRIBUTE Annex-Multilink-Id 75 integer
-ATTRIBUTE Annex-Num-In-Multilink 76 integer
-ATTRIBUTE Annex-Logical-Channel-Number 81 integer
-ATTRIBUTE Annex-Wan-Number 82 integer
-ATTRIBUTE Annex-Port 83 integer
-ATTRIBUTE Annex-Pool-Id 85 integer
-ATTRIBUTE Annex-Compression-Protocol 86 string
-ATTRIBUTE Annex-Transmitted-Packets 87 integer
-ATTRIBUTE Annex-Retransmitted-Packets 88 integer
-ATTRIBUTE Annex-Signal-to-Noise-Ratio 89 integer
-ATTRIBUTE Annex-Retrain-Requests-Sent 90 integer
-ATTRIBUTE Annex-Retrain-Requests-Rcvd 91 integer
-ATTRIBUTE Annex-Rate-Reneg-Req-Sent 92 integer
-ATTRIBUTE Annex-Rate-Reneg-Req-Rcvd 93 integer
-ATTRIBUTE Annex-Begin-Receive-Line-Level 94 integer
-ATTRIBUTE Annex-End-Receive-Line-Level 95 integer
-ATTRIBUTE Annex-Begin-Modulation 96 string
-ATTRIBUTE Annex-Error-Correction-Prot 97 string
-ATTRIBUTE Annex-End-Modulation 98 string
+ATTRIBUTE Annex-PPP-Trace-Level 64 integer
+ATTRIBUTE Annex-Pre-Input-Octets 65 integer
+ATTRIBUTE Annex-Pre-Output-Octets 66 integer
+ATTRIBUTE Annex-Pre-Input-Packets 67 integer
+ATTRIBUTE Annex-Pre-Output-Packets 68 integer
+ATTRIBUTE Annex-Connect-Progress 69 integer
+ATTRIBUTE Annex-Multicast-Rate-Limit 73 integer
+ATTRIBUTE Annex-Maximum-Call-Duration 74 integer
+ATTRIBUTE Annex-Multilink-Id 75 integer
+ATTRIBUTE Annex-Num-In-Multilink 76 integer
+ATTRIBUTE Annex-Secondary-Srv-Endpoint 79 string
+ATTRIBUTE Annex-Gwy-Selection-Mode 80 integer
+ATTRIBUTE Annex-Logical-Channel-Number 81 integer
+ATTRIBUTE Annex-Wan-Number 82 integer
+ATTRIBUTE Annex-Port 83 integer
+ATTRIBUTE Annex-Pool-Id 85 integer
+ATTRIBUTE Annex-Compression-Protocol 86 string
+ATTRIBUTE Annex-Transmitted-Packets 87 integer
+ATTRIBUTE Annex-Retransmitted-Packets 88 integer
+ATTRIBUTE Annex-Signal-to-Noise-Ratio 89 integer
+ATTRIBUTE Annex-Retrain-Requests-Sent 90 integer
+ATTRIBUTE Annex-Retrain-Requests-Rcvd 91 integer
+ATTRIBUTE Annex-Rate-Reneg-Req-Sent 92 integer
+ATTRIBUTE Annex-Rate-Reneg-Req-Rcvd 93 integer
+ATTRIBUTE Annex-Begin-Receive-Line-Level 94 integer
+ATTRIBUTE Annex-End-Receive-Line-Level 95 integer
+ATTRIBUTE Annex-Begin-Modulation 96 string
+ATTRIBUTE Annex-Error-Correction-Prot 97 string
+ATTRIBUTE Annex-End-Modulation 98 string
# Bay Router Specific Attributes
#
-ATTRIBUTE Annex-User-Level 100 integer Bay-Networks
-ATTRIBUTE Annex-Audit-Level 101 integer Bay-Networks
+ATTRIBUTE Annex-User-Level 100 integer
+ATTRIBUTE Annex-Audit-Level 101 integer
+# Contivity
+ATTRIBUTE CES-Group 102 string
# Annex Tunnel Authen Type Values
-VALUE Annex-Tunnel-Authen-Type none 0
-VALUE Annex-Tunnel-Authen-Type kmd5-128 1
+VALUE Annex-Tunnel-Authen-Type none 0
+VALUE Annex-Tunnel-Authen-Type kmd5-128 1
# Annex Tunnel Authen Mode Values
-VALUE Annex-Tunnel-Authen-Mode none 0
-VALUE Annex-Tunnel-Authen-Mode prefix-suffix 1
+VALUE Annex-Tunnel-Authen-Mode none 0
+VALUE Annex-Tunnel-Authen-Mode prefix-suffix 1
# Annex User Server Location Values
-VALUE Annex-User-Server-Location local 1
-VALUE Annex-User-Server-Location remote 2
+VALUE Annex-User-Server-Location local 1
+VALUE Annex-User-Server-Location remote 2
# Annex Addr Resolution Protocol Values
-VALUE Annex-Addr-Resolution-Protocol none 0
-VALUE Annex-Addr-Resolution-Protocol DHCP 1
+VALUE Annex-Addr-Resolution-Protocol none 0
+VALUE Annex-Addr-Resolution-Protocol DHCP 1
# Annex System Disconnect Reason Values
-VALUE Annex-System-Disc-Reason Unknown 0
-VALUE Annex-System-Disc-Reason Line-disconnected 1
-VALUE Annex-System-Disc-Reason Dial-failed 2
-VALUE Annex-System-Disc-Reason WAN-manager-error 3
-VALUE Annex-System-Disc-Reason Disconnect-reset 4
-VALUE Annex-System-Disc-Reason Error-from-adm_notify 5
-VALUE Annex-System-Disc-Reason Modem-down-adm_notify 6
-VALUE Annex-System-Disc-Reason PPP-protocol-disconnect 7
-VALUE Annex-System-Disc-Reason Inactivity-timer 8
-VALUE Annex-System-Disc-Reason CLI-Hangup-command 9
-VALUE Annex-System-Disc-Reason CLI-last-job 10
-VALUE Annex-System-Disc-Reason Session-timeout 11
-VALUE Annex-System-Disc-Reason Slave-termination 12
-VALUE Annex-System-Disc-Reason Abnormal-termination 13
-VALUE Annex-System-Disc-Reason DCD-wait-failed 14
-VALUE Annex-System-Disc-Reason CLI-inactivity 15
-VALUE Annex-System-Disc-Reason Admin-port-reset 16
-VALUE Annex-System-Disc-Reason CLI-auth-failed 17
-VALUE Annex-System-Disc-Reason Slave-auth-failed 18
-VALUE Annex-System-Disc-Reason PAP-auth-failed 19
-VALUE Annex-System-Disc-Reason CHAP-auth-failed 20
-VALUE Annex-System-Disc-Reason Local-modem-reset 21
-VALUE Annex-System-Disc-Reason Modem-dead 22
-VALUE Annex-System-Disc-Reason PPP-LCP-failure 23
-VALUE Annex-System-Disc-Reason PPP-IPCP-failure 24
-VALUE Annex-System-Disc-Reason PPP-IPXCP-failure 25
-VALUE Annex-System-Disc-Reason PPP-ATCP-failure 26
-VALUE Annex-System-Disc-Reason PPP-CCP-failure 27
-VALUE Annex-System-Disc-Reason PPP-MP-failure 28
-VALUE Annex-System-Disc-Reason PPP-IPCP-timeout 29
-VALUE Annex-System-Disc-Reason PPP-IPXCP-timeout 30
-VALUE Annex-System-Disc-Reason PPP-ATCP-timeout 31
-VALUE Annex-System-Disc-Reason PPP-CCP-timeout 32
-VALUE Annex-System-Disc-Reason PPP-MP-timeout 33
-VALUE Annex-System-Disc-Reason PPP-init-failure 34
-VALUE Annex-System-Disc-Reason PPP-Unknown 35
-VALUE Annex-System-Disc-Reason PPP-Dialback-failed 36
-VALUE Annex-System-Disc-Reason PPP-Address-In-Use 37
-VALUE Annex-System-Disc-Reason PPP-No-device 38
-VALUE Annex-System-Disc-Reason PPP-Modem-hangup-rcvd 39
-VALUE Annex-System-Disc-Reason PPP-Hangup-rcvd 40
-VALUE Annex-System-Disc-Reason PPP-Termination-rcvd 41
-VALUE Annex-System-Disc-Reason PPP-Kill-rcvd 42
-VALUE Annex-System-Disc-Reason PPP-Time-rcvd 43
-VALUE Annex-System-Disc-Reason PPP-No-memory 44
-VALUE Annex-System-Disc-Reason PPP-Connection-Abort 45
-VALUE Annex-System-Disc-Reason PPP-VPN-LCP-failure 46
-VALUE Annex-System-Disc-Reason PPP-VPN-Auth-failure 47
-VALUE Annex-System-Disc-Reason PPP-MP-invalid-port 48
-VALUE Annex-System-Disc-Reason PPP-Invalid-device 49
-VALUE Annex-System-Disc-Reason PPP-MMP-bundle-failure 50
-VALUE Annex-System-Disc-Reason DVS-Registration-failure 51
-VALUE Annex-System-Disc-Reason DVS-Home-agent-dereg 52
-VALUE Annex-System-Disc-Reason DVS-Tunnel-no-renew 53
-VALUE Annex-System-Disc-Reason DVS-Tunnel-expired 54
+VALUE Annex-System-Disc-Reason Unknown 0
+VALUE Annex-System-Disc-Reason Line-disconnected 1
+VALUE Annex-System-Disc-Reason Dial-failed 2
+VALUE Annex-System-Disc-Reason WAN-manager-error 3
+VALUE Annex-System-Disc-Reason Disconnect-reset 4
+VALUE Annex-System-Disc-Reason Error-from-adm_notify 5
+VALUE Annex-System-Disc-Reason Modem-down-adm_notify 6
+VALUE Annex-System-Disc-Reason PPP-protocol-disconnect 7
+VALUE Annex-System-Disc-Reason Inactivity-timer 8
+VALUE Annex-System-Disc-Reason CLI-Hangup-command 9
+VALUE Annex-System-Disc-Reason CLI-last-job 10
+VALUE Annex-System-Disc-Reason Session-timeout 11
+VALUE Annex-System-Disc-Reason Slave-termination 12
+VALUE Annex-System-Disc-Reason Abnormal-termination 13
+VALUE Annex-System-Disc-Reason DCD-wait-failed 14
+VALUE Annex-System-Disc-Reason CLI-inactivity 15
+VALUE Annex-System-Disc-Reason Admin-port-reset 16
+VALUE Annex-System-Disc-Reason CLI-auth-failed 17
+VALUE Annex-System-Disc-Reason Slave-auth-failed 18
+VALUE Annex-System-Disc-Reason PAP-auth-failed 19
+VALUE Annex-System-Disc-Reason CHAP-auth-failed 20
+VALUE Annex-System-Disc-Reason Local-modem-reset 21
+VALUE Annex-System-Disc-Reason Modem-dead 22
+VALUE Annex-System-Disc-Reason PPP-LCP-failure 23
+VALUE Annex-System-Disc-Reason PPP-IPCP-failure 24
+VALUE Annex-System-Disc-Reason PPP-IPXCP-failure 25
+VALUE Annex-System-Disc-Reason PPP-ATCP-failure 26
+VALUE Annex-System-Disc-Reason PPP-CCP-failure 27
+VALUE Annex-System-Disc-Reason PPP-MP-failure 28
+VALUE Annex-System-Disc-Reason PPP-IPCP-timeout 29
+VALUE Annex-System-Disc-Reason PPP-IPXCP-timeout 30
+VALUE Annex-System-Disc-Reason PPP-ATCP-timeout 31
+VALUE Annex-System-Disc-Reason PPP-CCP-timeout 32
+VALUE Annex-System-Disc-Reason PPP-MP-timeout 33
+VALUE Annex-System-Disc-Reason PPP-init-failure 34
+VALUE Annex-System-Disc-Reason PPP-Unknown 35
+VALUE Annex-System-Disc-Reason PPP-Dialback-failed 36
+VALUE Annex-System-Disc-Reason PPP-Address-In-Use 37
+VALUE Annex-System-Disc-Reason PPP-No-device 38
+VALUE Annex-System-Disc-Reason PPP-Modem-hangup-rcvd 39
+VALUE Annex-System-Disc-Reason PPP-Hangup-rcvd 40
+VALUE Annex-System-Disc-Reason PPP-Termination-rcvd 41
+VALUE Annex-System-Disc-Reason PPP-Kill-rcvd 42
+VALUE Annex-System-Disc-Reason PPP-Time-rcvd 43
+VALUE Annex-System-Disc-Reason PPP-No-memory 44
+VALUE Annex-System-Disc-Reason PPP-Connection-Abort 45
+VALUE Annex-System-Disc-Reason PPP-VPN-LCP-failure 46
+VALUE Annex-System-Disc-Reason PPP-VPN-Auth-failure 47
+VALUE Annex-System-Disc-Reason PPP-MP-invalid-port 48
+VALUE Annex-System-Disc-Reason PPP-Invalid-device 49
+VALUE Annex-System-Disc-Reason PPP-MMP-bundle-failure 50
+VALUE Annex-System-Disc-Reason DVS-Registration-failure 51
+VALUE Annex-System-Disc-Reason DVS-Home-agent-dereg 52
+VALUE Annex-System-Disc-Reason DVS-Tunnel-no-renew 53
+VALUE Annex-System-Disc-Reason DVS-Tunnel-expired 54
# Annex Modem Disconnect Reason Values
-VALUE Annex-Modem-Disc-Reason Unknown 0
-VALUE Annex-Modem-Disc-Reason Local-disconnect 1
-VALUE Annex-Modem-Disc-Reason CD-Timer-Expired 2
-VALUE Annex-Modem-Disc-Reason Remote-protocol-disc 4
-VALUE Annex-Modem-Disc-Reason Clear-down 5
-VALUE Annex-Modem-Disc-Reason Long-Space-disconnect 6
-VALUE Annex-Modem-Disc-Reason Carrier-Lost 7
-VALUE Annex-Modem-Disc-Reason Modem-Retrain-Timeout 8
+VALUE Annex-Modem-Disc-Reason Unknown 0
+VALUE Annex-Modem-Disc-Reason Local-disconnect 1
+VALUE Annex-Modem-Disc-Reason CD-Timer-Expired 2
+VALUE Annex-Modem-Disc-Reason Remote-protocol-disc 4
+VALUE Annex-Modem-Disc-Reason Clear-down 5
+VALUE Annex-Modem-Disc-Reason Long-Space-disconnect 6
+VALUE Annex-Modem-Disc-Reason Carrier-Lost 7
+VALUE Annex-Modem-Disc-Reason Modem-Retrain-Timeout 8
# Annex Connection Progress Values
#VALUE Annex-Connect-Progress LCP-Is-In-Ack-Recvd-State 76
#VALUE Annex-Connect-Progress LCP-Is-In-Ack-Sent-State 77
#VALUE Annex-Connect-Progress IPXCP-Is-In-Open-State 80
-
+
#VALUE Annex-Multicast-Client Multicast-No 0
#VALUE Annex-Multicast-Client Multicast-Yes 1
#VALUE Annex-Pool-Id Pool-Five 5
#VALUE Annex-Pool-Id Pool-Six 6
-VALUE Annex-User-Level Manager 2
-VALUE Annex-User-Level User 4
-VALUE Annex-User-Level Operator 8
+VALUE Annex-User-Level Manager 2
+VALUE Annex-User-Level User 4
+VALUE Annex-User-Level Operator 8
-VALUE Annex-Audit-Level Manager 2
-VALUE Annex-Audit-Level User 4
-VALUE Annex-Audit-Level Operator 8
+VALUE Annex-Audit-Level Manager 2
+VALUE Annex-Audit-Level User 4
+VALUE Annex-Audit-Level Operator 8
END-VENDOR Bay-Networks
# VALUE extensions to the standard RADIUS attributes.
#
-VALUE Service-Type Annex-Authorize-Only 0x06300001
-VALUE Service-Type Annex-Framed-Tunnel 0x06300002
+VALUE Service-Type Annex-Authorize-Only 0x06300001
+VALUE Service-Type Annex-Framed-Tunnel 0x06300002
-VALUE Acct-Status-Type Annex-User-Reject 0x06300001
-VALUE Acct-Status-Type Annex-Call-Reject 0x06300002
-VALUE Acct-Status-Type Annex-IPCP-Start 0x06300003
-VALUE Acct-Status-Type Annex-IPXCP-Start 0x06300004
-VALUE Acct-Status-Type Annex-ATCP-Start 0x06300005
-VALUE Acct-Status-Type Annex-Accounting-Restart 0x06300006
-VALUE Acct-Status-Type Annex-Accounting-Shutoff 0x06300007
-VALUE Acct-Status-Type Annex-Tunnel-Start 0x06300008
-VALUE Acct-Status-Type Annex-Tunnel-Stop 0x06300009
-VALUE Acct-Status-Type Annex-Tunnel-Reject 0x0630000a
-VALUE Acct-Status-Type Annex-Tunnel-Link-Start 0x0630000b
-VALUE Acct-Status-Type Annex-Tunnel-Link-Stop 0x0630000c
-VALUE Acct-Status-Type Annex-MP-Start 0x0630000d
-VALUE Acct-Status-Type Annex-MP-Stop 0x0630000e
-VALUE Acct-Status-Type Annex-Line-Seizure 0x0630000f
-VALUE Acct-Status-Type Annex-Rlogin-Start 0x06300010
-VALUE Acct-Status-Type Annex-Rlogin-Stop 0x06300011
+VALUE Acct-Status-Type Annex-User-Reject 0x06300001
+VALUE Acct-Status-Type Annex-Call-Reject 0x06300002
+VALUE Acct-Status-Type Annex-IPCP-Start 0x06300003
+VALUE Acct-Status-Type Annex-IPXCP-Start 0x06300004
+VALUE Acct-Status-Type Annex-ATCP-Start 0x06300005
+VALUE Acct-Status-Type Annex-Accounting-Restart 0x06300006
+VALUE Acct-Status-Type Annex-Accounting-Shutoff 0x06300007
+VALUE Acct-Status-Type Annex-Tunnel-Start 0x06300008
+VALUE Acct-Status-Type Annex-Tunnel-Stop 0x06300009
+VALUE Acct-Status-Type Annex-Tunnel-Reject 0x0630000a
+VALUE Acct-Status-Type Annex-Tunnel-Link-Start 0x0630000b
+VALUE Acct-Status-Type Annex-Tunnel-Link-Stop 0x0630000c
+VALUE Acct-Status-Type Annex-MP-Start 0x0630000d
+VALUE Acct-Status-Type Annex-MP-Stop 0x0630000e
+VALUE Acct-Status-Type Annex-Line-Seizure 0x0630000f
+VALUE Acct-Status-Type Annex-Rlogin-Start 0x06300010
+VALUE Acct-Status-Type Annex-Rlogin-Stop 0x06300011
+# -*- text -*-
#
# Bintec dictionary
# $Id$
#
#
#
-VENDOR BinTec 272
+VENDOR BinTec 272
# (272 << 16) | N
#
-VALUE Framed-Protocol X25 17825794
-VALUE Framed-Protocol X25-PPP 17825795
-VALUE Framed-Protocol IP-LAPB 17825796
-VALUE Framed-Protocol IP-HDLC 17825798
-VALUE Framed-Protocol MPR-LAPB 17825799
-VALUE Framed-Protocol MPR-HDLC 17825800
-VALUE Framed-Protocol FRAME-RELAY 17825801
-VALUE Framed-Protocol X31-BCHAN 17825802
-VALUE Framed-Protocol X75-PPP 17825803
-VALUE Framed-Protocol X75BTX-PPP 17825804
-VALUE Framed-Protocol X25-NOSIG 17825805
-VALUE Framed-Protocol X25-PPP-OPT 17825806
+VALUE Framed-Protocol Bintec-X25 0x01100002
+VALUE Framed-Protocol Bintec-X25-PPP 0x01100003
+VALUE Framed-Protocol Bintec-IP-LAPB 0x01100004
+VALUE Framed-Protocol Bintec-IP-HDLC 0x01100006
+VALUE Framed-Protocol Bintec-MPR-LAPB 0x01100007
+VALUE Framed-Protocol Bintec-MPR-HDLC 0x01100008
+VALUE Framed-Protocol Bintec-FRAME-RELAY 0x01100009
+VALUE Framed-Protocol Bintec-X31-BCHAN 0x0110000a
+VALUE Framed-Protocol Bintec-X75-PPP 0x0110000b
+VALUE Framed-Protocol Bintec-X75BTX-PPP 0x0110000c
+VALUE Framed-Protocol Bintec-X25-NOSIG 0x0110000d
+VALUE Framed-Protocol Bintec-X25-PPP-OPT 0x0110000e
#
#
-ATTRIBUTE BinTec-biboPPPTable 224 string BinTec
-ATTRIBUTE BinTec-biboDialTable 225 string BinTec
-ATTRIBUTE BinTec-ipExtIfTable 226 string BinTec
-ATTRIBUTE BinTec-ipRouteTable 227 string BinTec
-ATTRIBUTE BinTec-ipExtRtTable 228 string BinTec
-ATTRIBUTE BinTec-ipNatPresetTable 229 string BinTec
-ATTRIBUTE BinTec-ipxCircTable 230 string BinTec
-ATTRIBUTE BinTec-ripCircTable 231 string BinTec
-ATTRIBUTE BinTec-sapCircTable 232 string BinTec
-ATTRIBUTE BinTec-ipxStaticRouteTable 233 string BinTec
-ATTRIBUTE BinTec-ipxStaticServTable 234 string BinTec
-ATTRIBUTE BinTec-ospfIfTable 235 string BinTec
-ATTRIBUTE BinTec-pppExtIfTable 236 string BinTec
-ATTRIBUTE BinTec-ipFilterTable 237 string BinTec
-ATTRIBUTE BinTec-ipQoSTable 238 string BinTec
-ATTRIBUTE BinTec-qosIfTable 239 string BinTec
-ATTRIBUTE BinTec-qosPolicyTable 240 string BinTec
+BEGIN-VENDOR BinTec
+
+ATTRIBUTE BinTec-biboPPPTable 224 string
+ATTRIBUTE BinTec-biboDialTable 225 string
+ATTRIBUTE BinTec-ipExtIfTable 226 string
+ATTRIBUTE BinTec-ipRouteTable 227 string
+ATTRIBUTE BinTec-ipExtRtTable 228 string
+ATTRIBUTE BinTec-ipNatPresetTable 229 string
+ATTRIBUTE BinTec-ipxCircTable 230 string
+ATTRIBUTE BinTec-ripCircTable 231 string
+ATTRIBUTE BinTec-sapCircTable 232 string
+ATTRIBUTE BinTec-ipxStaticRouteTable 233 string
+ATTRIBUTE BinTec-ipxStaticServTable 234 string
+ATTRIBUTE BinTec-ospfIfTable 235 string
+ATTRIBUTE BinTec-pppExtIfTable 236 string
+ATTRIBUTE BinTec-ipFilterTable 237 string
+ATTRIBUTE BinTec-ipQoSTable 238 string
+ATTRIBUTE BinTec-qosIfTable 239 string
+ATTRIBUTE BinTec-qosPolicyTable 240 string
+
+END-VENDOR BinTec
+# -*- text -*-
#
# dictionary.bristol
#
# Version: $Id$
#
-VENDOR Bristol 4363
+VENDOR Bristol 4363
#
# Standard attribute
#
-ATTRIBUTE NN-Data-Rate 1 integer Bristol
-ATTRIBUTE NN-Data-Rate-Ceiling 2 integer Bristol
-ATTRIBUTE NN-Homenode 3 ipaddr Bristol
-ATTRIBUTE NN-Homeservice 4 ipaddr Bristol
-ATTRIBUTE NN-Homeservice-Name 5 string Bristol
+BEGIN-VENDOR Bristol
+
+ATTRIBUTE NN-Data-Rate 1 integer
+ATTRIBUTE NN-Data-Rate-Ceiling 2 integer
+ATTRIBUTE NN-Homenode 3 ipaddr
+ATTRIBUTE NN-Homeservice 4 ipaddr
+ATTRIBUTE NN-Homeservice-Name 5 string
+
+END-VENDOR Bristol
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# CableLabs
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR CableLabs 4491
+
+BEGIN-VENDOR CableLabs
+
+ATTRIBUTE CableLabs-Reserved 0 octets
+ATTRIBUTE CableLabs-Event-Message 1 octets
+ATTRIBUTE CableLabs-MTA-Endpoint-Name 3 string
+ATTRIBUTE CableLabs-Calling-Party-Number 4 string
+ATTRIBUTE CableLabs-Called-Party-Number 5 string
+ATTRIBUTE CableLabs-Database-ID 6 string
+ATTRIBUTE CableLabs-Query-Type 7 integer
+ATTRIBUTE CableLabs-Returned-Number 9 string
+ATTRIBUTE CableLabs-Call-Termination-Cause 11 octets
+
+#ATTRIBUTE CableLabs-Related-Call-Billing-Correlation-ID 13 octets
+ATTRIBUTE CableLabs-Related-Call-Billing-Crl-ID 13 octets
+
+#ATTRIBUTE CableLabs-First-Call-Calling-Party-Number 14 string
+#ATTRIBUTE CableLabs-Second-Call-Calling-Party-Number 15 string
+ATTRIBUTE CableLabs-First-Call-Calling-Party-Num 14 string
+ATTRIBUTE CableLabs-Second-Call-Calling-Party-Num 15 string
+
+ATTRIBUTE CableLabs-Charge-Number 16 string
+ATTRIBUTE CableLabs-Forwarded-Number 17 string
+ATTRIBUTE CableLabs-Service-Name 18 string
+ATTRIBUTE CableLabs-Intl-Code 20 string
+ATTRIBUTE CableLabs-Dial-Around-Code 21 string
+ATTRIBUTE CableLabs-Location-Routing-Number 22 string
+ATTRIBUTE CableLabs-Carrier-Identification-Code 23 string
+ATTRIBUTE CableLabs-Trunk-Group-ID 24 octets
+ATTRIBUTE CableLabs-Routing-Number 25 string
+ATTRIBUTE CableLabs-MTA-UDP-Portnum 26 integer
+ATTRIBUTE CableLabs-Channel-State 29 integer
+ATTRIBUTE CableLabs-SF-ID 30 integer
+ATTRIBUTE CableLabs-Error-Description 31 string
+ATTRIBUTE CableLabs-QoS-Descriptor 32 octets
+ATTRIBUTE CableLabs-Direction-indicator 37 integer
+ATTRIBUTE CableLabs-Time-Adjustment 38 octets
+ATTRIBUTE CableLabs-SDP-Upstream 39 string
+ATTRIBUTE CableLabs-SDP-Downstream 40 string
+ATTRIBUTE CableLabs-User-Input 41 string
+ATTRIBUTE CableLabs-Translation-Input 42 string
+ATTRIBUTE CableLabs-Redirected-From-Info 43 octets
+
+#ATTRIBUTE CableLabs-Electronic-Surveillance-Indication 44 octets
+ATTRIBUTE CableLabs-Electronic-Surveillance-Ind 44 octets
+
+ATTRIBUTE CableLabs-Redirected-From-Party-Number 45 string
+ATTRIBUTE CableLabs-Redirected-To-Party-Number 46 string
+
+#ATTRIBUTE CableLabs-Electronic-Surveillance-DF-Security 47 octets
+ATTRIBUTE CableLabs-El-Surveillance-DF-Security 47 octets
+
+ATTRIBUTE CableLabs-CCC-ID 48 octets
+ATTRIBUTE CableLabs-Financial-Entity-ID 49 string
+ATTRIBUTE CableLabs-Flow-Direction 50 integer
+ATTRIBUTE CableLabs-Signal-Type 51 integer
+ATTRIBUTE CableLabs-Alerting-Signal 52 integer
+ATTRIBUTE CableLabs-Subject-Audible-Signal 53 integer
+ATTRIBUTE CableLabs-Terminal-Display-Info 54 octets
+ATTRIBUTE CableLabs-Switch-Hook-Flash 55 string
+ATTRIBUTE CableLabs-Dialed-Digits 56 string
+ATTRIBUTE CableLabs-Misc-Signaling-Information 57 string
+ATTRIBUTE CableLabs-AM-Opaque-Data 61 integer
+ATTRIBUTE CableLabs-Subscriber-ID 62 integer
+ATTRIBUTE CableLabs-Volume-Usage-Limit 63 integer
+ATTRIBUTE CableLabs-Gate-Usage-Info 64 integer
+ATTRIBUTE CableLabs-Element-Requesting-QoS 65 integer
+ATTRIBUTE CableLabs-QoS-Release-Reason 66 integer
+ATTRIBUTE CableLabs-Policy-Denied-Reason 67 integer
+ATTRIBUTE CableLabs-Policy-Deleted-Reason 68 integer
+ATTRIBUTE CableLabs-Policy-Update-Reason 69 integer
+ATTRIBUTE CableLabs-Policy-Decision-Status 70 integer
+ATTRIBUTE CableLabs-Application-Manager-ID 71 integer
+ATTRIBUTE CableLabs-Time-Usage-Limit 72 integer
+ATTRIBUTE CableLabs-Gate-Time-Info 73 integer
+ATTRIBUTE CableLabs-Account-Code 80 string
+ATTRIBUTE CableLabs-Authorization-Code 81 string
+
+VALUE CableLabs-Event-Message Reserved 0
+VALUE CableLabs-Event-Message Signaling-Start 1
+VALUE CableLabs-Event-Message Signaling-Stop 2
+VALUE CableLabs-Event-Message Database-Query 3
+VALUE CableLabs-Event-Message Intelligent-Peripheral-Usage-Start 4
+VALUE CableLabs-Event-Message Intelligent-Peripheral-Usage-Stop 5
+VALUE CableLabs-Event-Message Service-Instance 6
+VALUE CableLabs-Event-Message QoS-Reserve 7
+VALUE CableLabs-Event-Message QoS-Release 8
+VALUE CableLabs-Event-Message Service-Activation 9
+VALUE CableLabs-Event-Message Service-Deactivation 10
+VALUE CableLabs-Event-Message Media-Report 11
+VALUE CableLabs-Event-Message Signal-Instance 12
+VALUE CableLabs-Event-Message Interconnect-Signaling-Start 13
+VALUE CableLabs-Event-Message Interconnect-Signaling-Stop 14
+VALUE CableLabs-Event-Message Call-Answer 15
+VALUE CableLabs-Event-Message Call-Disconnect 16
+VALUE CableLabs-Event-Message Time-Change 17
+VALUE CableLabs-Event-Message QoS-Commit 19
+VALUE CableLabs-Event-Message Media-Alive 20
+VALUE CableLabs-Event-Message Policy-Request 31
+VALUE CableLabs-Event-Message Policy-Delete 32
+VALUE CableLabs-Event-Message Policy-Update 33
+
+VALUE CableLabs-Query-Type Reserved 0
+VALUE CableLabs-Query-Type Toll-Free-Number-Looukp 1
+VALUE CableLabs-Query-Type LNP-Number-Lookup 2
+VALUE CableLabs-Query-Type Calling-Name-Delivery-Lookup 3
+
+VALUE CableLabs-Channel-State Reserved 0
+VALUE CableLabs-Channel-State Open 1
+VALUE CableLabs-Channel-State Change 2
+VALUE CableLabs-Channel-State Close 3
+
+VALUE CableLabs-Direction-indicator Undefined 0
+VALUE CableLabs-Direction-indicator Originating 1
+VALUE CableLabs-Direction-indicator Terminating 2
+
+VALUE CableLabs-Flow-Direction Reserved 0
+VALUE CableLabs-Flow-Direction Upstream 1
+VALUE CableLabs-Flow-Direction Downstream 2
+
+VALUE CableLabs-Signal-Type Reserved 0
+VALUE CableLabs-Signal-Type Network-Signal 1
+VALUE CableLabs-Signal-Type Subject-Signal 2
+
+VALUE CableLabs-Alerting-Signal Reserved-0 0
+VALUE CableLabs-Alerting-Signal Ringing 1
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-2 2
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-3 3
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-4 4
+VALUE CableLabs-Alerting-Signal Ringsplash 5
+VALUE CableLabs-Alerting-Signal Call-Waiting-Tone-1 6
+VALUE CableLabs-Alerting-Signal Call-Waiting-Tone-2 7
+VALUE CableLabs-Alerting-Signal Call-Waiting-Tone-3 8
+VALUE CableLabs-Alerting-Signal Call-Waiting-Tone-4 9
+VALUE CableLabs-Alerting-Signal Reserved-10 10
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-0 11
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-1 12
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-5 13
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-6 14
+VALUE CableLabs-Alerting-Signal Distinctive-Ringing-7 15
+
+VALUE CableLabs-AM-Opaque-Data Reserved-0 0
+VALUE CableLabs-AM-Opaque-Data Dial-Tone 1
+VALUE CableLabs-AM-Opaque-Data Stutter-Dial-Tone 2
+VALUE CableLabs-AM-Opaque-Data Ring-Back-Tone 3
+VALUE CableLabs-AM-Opaque-Data Reorder-Tone 4
+VALUE CableLabs-AM-Opaque-Data Busy-Tone 5
+VALUE CableLabs-AM-Opaque-Data Confirmation-Tone 6
+VALUE CableLabs-AM-Opaque-Data Reserved-7 7
+VALUE CableLabs-AM-Opaque-Data Message-Waiting-Indicator 8
+VALUE CableLabs-AM-Opaque-Data Off-hook-Warning-Tone 9
+
+VALUE CableLabs-Element-Requesting-QoS Client 0
+VALUE CableLabs-Element-Requesting-QoS Policy-Server 1
+VALUE CableLabs-Element-Requesting-QoS Embedded-Client 2
+
+VALUE CableLabs-QoS-Release-Reason Gate-Closed-By-PS 1
+VALUE CableLabs-QoS-Release-Reason Inactivity-Resource-Recovery-Timer-Expiration 2
+VALUE CableLabs-QoS-Release-Reason CM-Failure 3
+VALUE CableLabs-QoS-Release-Reason Pre-Empted 4
+VALUE CableLabs-QoS-Release-Reason RSVP-PathTear-request 5
+VALUE CableLabs-QoS-Release-Reason CM-Request 6
+VALUE CableLabs-QoS-Release-Reason Admitted-Timer-Expiration 7
+VALUE CableLabs-QoS-Release-Reason Other 127
+
+VALUE CableLabs-Policy-Denied-Reason Policy-Server-Admission-Control-Failure 1
+VALUE CableLabs-Policy-Denied-Reason Insufficient-Resources 2
+VALUE CableLabs-Policy-Denied-Reason Unknown-Subscriber 3
+VALUE CableLabs-Policy-Denied-Reason Unauthorized-AMID 4
+VALUE CableLabs-Policy-Denied-Reason Undefined-Service-Class-Name 5
+VALUE CableLabs-Policy-Denied-Reason Incompatible-Envelope 6
+VALUE CableLabs-Policy-Denied-Reason Other 127
+
+VALUE CableLabs-Policy-Deleted-Reason Application-Manager-Request 1
+VALUE CableLabs-Policy-Deleted-Reason CMTS-Decistion 2
+VALUE CableLabs-Policy-Deleted-Reason Other 127
+
+VALUE CableLabs-Policy-Update-Reason Traffic-Profile 1
+VALUE CableLabs-Policy-Update-Reason Classifier 2
+VALUE CableLabs-Policy-Update-Reason Volume-Limit 3
+VALUE CableLabs-Policy-Update-Reason Time-Limit 4
+VALUE CableLabs-Policy-Update-Reason Opaque-Data 5
+VALUE CableLabs-Policy-Update-Reason Multiple-Updates 6
+VALUE CableLabs-Policy-Update-Reason Other 127
+
+VALUE CableLabs-Policy-Decision-Status Policy-Approved 1
+VALUE CableLabs-Policy-Decision-Status Policy-Denied 2
+
+END-VENDOR CableLabs
+# -*- text -*-
#
# http://www.cabletron.com (now http://www.enterasys.com)
# $Id$
#
-VENDOR Cabletron 52
+VENDOR Cabletron 52
-ATTRIBUTE Cabletron-Protocol-Enable 201 integer Cabletron
-ATTRIBUTE Cabletron-Protocol-Callable 202 integer Cabletron
+BEGIN-VENDOR Cabletron
-VALUE Cabletron-Protocol-Enable IP-Enable 1
-VALUE Cabletron-Protocol-Enable Bridge-Enable 2
-VALUE Cabletron-Protocol-Enable IP-BR-Enable 3
-VALUE Cabletron-Protocol-Enable BR-IPX-Enable 6
-VALUE Cabletron-Protocol-Enable IP-BR-IPX-Enable 7
+ATTRIBUTE Cabletron-Protocol-Enable 201 integer
+ATTRIBUTE Cabletron-Protocol-Callable 202 integer
-VALUE Cabletron-Protocol-Callable IP-Callable 1
-VALUE Cabletron-Protocol-Callable Bridge-Callable 2
-VALUE Cabletron-Protocol-Callable IP-BR-Callable 3
-VALUE Cabletron-Protocol-Callable BR-IPX-Callable 6
-VALUE Cabletron-Protocol-Callable IP-BR-IPX-Callable 7
+VALUE Cabletron-Protocol-Enable IP-Enable 1
+VALUE Cabletron-Protocol-Enable Bridge-Enable 2
+VALUE Cabletron-Protocol-Enable IP-BR-Enable 3
+VALUE Cabletron-Protocol-Enable BR-IPX-Enable 6
+VALUE Cabletron-Protocol-Enable IP-BR-IPX-Enable 7
+
+VALUE Cabletron-Protocol-Callable IP-Callable 1
+VALUE Cabletron-Protocol-Callable Bridge-Callable 2
+VALUE Cabletron-Protocol-Callable IP-BR-Callable 3
+VALUE Cabletron-Protocol-Callable BR-IPX-Callable 6
+VALUE Cabletron-Protocol-Callable IP-BR-IPX-Callable 7
+
+END-VENDOR Cabletron
+# -*- text -*-
#
# dictionary.cisco
#
# "Marcelo M. Sosa Lugones" <marcelo@sosa.com.ar>
#
# Version: $Id$
-#
+#
# For documentation on Cisco RADIUS attributes, see:
#
# http://www.cisco.com/univercd/cc/td/doc/product/access/acs_serv/vapp_dev/vsaig3.htm
#
-VENDOR Cisco 9
+VENDOR Cisco 9
#
# Standard attribute
#
-ATTRIBUTE Cisco-AVPair 1 string Cisco
-ATTRIBUTE Cisco-NAS-Port 2 string Cisco
+BEGIN-VENDOR Cisco
+
+ATTRIBUTE Cisco-AVPair 1 string
+ATTRIBUTE Cisco-NAS-Port 2 string
#
# T.37 Store-and-Forward attributes.
#
-ATTRIBUTE Cisco-Fax-Account-Id-Origin 3 string Cisco
-ATTRIBUTE Cisco-Fax-Msg-Id 4 string Cisco
-ATTRIBUTE Cisco-Fax-Pages 5 string Cisco
-ATTRIBUTE Cisco-Fax-Coverpage-Flag 6 string Cisco
-ATTRIBUTE Cisco-Fax-Modem-Time 7 string Cisco
-ATTRIBUTE Cisco-Fax-Connect-Speed 8 string Cisco
-ATTRIBUTE Cisco-Fax-Recipient-Count 9 string Cisco
-ATTRIBUTE Cisco-Fax-Process-Abort-Flag 10 string Cisco
-ATTRIBUTE Cisco-Fax-Dsn-Address 11 string Cisco
-ATTRIBUTE Cisco-Fax-Dsn-Flag 12 string Cisco
-ATTRIBUTE Cisco-Fax-Mdn-Address 13 string Cisco
-ATTRIBUTE Cisco-Fax-Mdn-Flag 14 string Cisco
-ATTRIBUTE Cisco-Fax-Auth-Status 15 string Cisco
-ATTRIBUTE Cisco-Email-Server-Address 16 string Cisco
-ATTRIBUTE Cisco-Email-Server-Ack-Flag 17 string Cisco
-ATTRIBUTE Cisco-Gateway-Id 18 string Cisco
-ATTRIBUTE Cisco-Call-Type 19 string Cisco
-ATTRIBUTE Cisco-Port-Used 20 string Cisco
-ATTRIBUTE Cisco-Abort-Cause 21 string Cisco
+ATTRIBUTE Cisco-Fax-Account-Id-Origin 3 string
+ATTRIBUTE Cisco-Fax-Msg-Id 4 string
+ATTRIBUTE Cisco-Fax-Pages 5 string
+ATTRIBUTE Cisco-Fax-Coverpage-Flag 6 string
+ATTRIBUTE Cisco-Fax-Modem-Time 7 string
+ATTRIBUTE Cisco-Fax-Connect-Speed 8 string
+ATTRIBUTE Cisco-Fax-Recipient-Count 9 string
+ATTRIBUTE Cisco-Fax-Process-Abort-Flag 10 string
+ATTRIBUTE Cisco-Fax-Dsn-Address 11 string
+ATTRIBUTE Cisco-Fax-Dsn-Flag 12 string
+ATTRIBUTE Cisco-Fax-Mdn-Address 13 string
+ATTRIBUTE Cisco-Fax-Mdn-Flag 14 string
+ATTRIBUTE Cisco-Fax-Auth-Status 15 string
+ATTRIBUTE Cisco-Email-Server-Address 16 string
+ATTRIBUTE Cisco-Email-Server-Ack-Flag 17 string
+ATTRIBUTE Cisco-Gateway-Id 18 string
+ATTRIBUTE Cisco-Call-Type 19 string
+ATTRIBUTE Cisco-Port-Used 20 string
+ATTRIBUTE Cisco-Abort-Cause 21 string
#
# Voice over IP attributes.
#
-ATTRIBUTE h323-remote-address 23 string Cisco
-ATTRIBUTE h323-conf-id 24 string Cisco
-ATTRIBUTE h323-setup-time 25 string Cisco
-ATTRIBUTE h323-call-origin 26 string Cisco
-ATTRIBUTE h323-call-type 27 string Cisco
-ATTRIBUTE h323-connect-time 28 string Cisco
-ATTRIBUTE h323-disconnect-time 29 string Cisco
-ATTRIBUTE h323-disconnect-cause 30 string Cisco
-ATTRIBUTE h323-voice-quality 31 string Cisco
-ATTRIBUTE h323-gw-id 33 string Cisco
-ATTRIBUTE h323-incoming-conf-id 35 string Cisco
-
-ATTRIBUTE h323-credit-amount 101 string Cisco
-ATTRIBUTE h323-credit-time 102 string Cisco
-ATTRIBUTE h323-return-code 103 string Cisco
-ATTRIBUTE h323-prompt-id 104 string Cisco
-ATTRIBUTE h323-time-and-day 105 string Cisco
-ATTRIBUTE h323-redirect-number 106 string Cisco
-ATTRIBUTE h323-preferred-lang 107 string Cisco
-ATTRIBUTE h323-redirect-ip-address 108 string Cisco
-ATTRIBUTE h323-billing-model 109 string Cisco
-ATTRIBUTE h323-currency 110 string Cisco
-ATTRIBUTE subscriber 111 string Cisco
-ATTRIBUTE gw-rxd-cdn 112 string Cisco
-ATTRIBUTE gw-final-xlated-cdn 113 string Cisco
+ATTRIBUTE h323-remote-address 23 string
+ATTRIBUTE h323-conf-id 24 string
+ATTRIBUTE h323-setup-time 25 string
+ATTRIBUTE h323-call-origin 26 string
+ATTRIBUTE h323-call-type 27 string
+ATTRIBUTE h323-connect-time 28 string
+ATTRIBUTE h323-disconnect-time 29 string
+ATTRIBUTE h323-disconnect-cause 30 string
+ATTRIBUTE h323-voice-quality 31 string
+ATTRIBUTE h323-gw-id 33 string
+ATTRIBUTE h323-incoming-conf-id 35 string
+ATTRIBUTE h323-credit-amount 101 string
+ATTRIBUTE h323-credit-time 102 string
+ATTRIBUTE h323-return-code 103 string
+ATTRIBUTE h323-prompt-id 104 string
+ATTRIBUTE h323-time-and-day 105 string
+ATTRIBUTE h323-redirect-number 106 string
+ATTRIBUTE h323-preferred-lang 107 string
+ATTRIBUTE h323-redirect-ip-address 108 string
+ATTRIBUTE h323-billing-model 109 string
+ATTRIBUTE h323-currency 110 string
+ATTRIBUTE subscriber 111 string
+ATTRIBUTE gw-rxd-cdn 112 string
+ATTRIBUTE gw-final-xlated-cdn 113 string
+ATTRIBUTE remote-media-address 114 string
+ATTRIBUTE release-source 115 string
+ATTRIBUTE gw-rxd-cgn 116 string
+ATTRIBUTE gw-final-xlated-cgn 117 string
# SIP Attributes
-ATTRIBUTE call-id 141 string Cisco
-ATTRIBUTE session-protocol 142 string Cisco
-ATTRIBUTE method 143 string Cisco
-ATTRIBUTE prev-hop-via 144 string Cisco
-ATTRIBUTE prev-hop-ip 145 string Cisco
-ATTRIBUTE incoming-req-uri 146 string Cisco
-ATTRIBUTE outgoing-req-uri 147 string Cisco
-ATTRIBUTE next-hop-ip 148 string Cisco
-ATTRIBUTE next-hop-dn 149 string Cisco
-ATTRIBUTE sip-hdr 150 string Cisco
+ATTRIBUTE call-id 141 string
+ATTRIBUTE session-protocol 142 string
+ATTRIBUTE method 143 string
+ATTRIBUTE prev-hop-via 144 string
+ATTRIBUTE prev-hop-ip 145 string
+ATTRIBUTE incoming-req-uri 146 string
+ATTRIBUTE outgoing-req-uri 147 string
+ATTRIBUTE next-hop-ip 148 string
+ATTRIBUTE next-hop-dn 149 string
+ATTRIBUTE sip-hdr 150 string
#
# Extra attributes sent by the Cisco, if you configure
# "radius-server vsa accounting" (requires IOS11.2+).
#
-ATTRIBUTE Cisco-Multilink-ID 187 integer Cisco
-ATTRIBUTE Cisco-Num-In-Multilink 188 integer Cisco
-ATTRIBUTE Cisco-Pre-Input-Octets 190 integer Cisco
-ATTRIBUTE Cisco-Pre-Output-Octets 191 integer Cisco
-ATTRIBUTE Cisco-Pre-Input-Packets 192 integer Cisco
-ATTRIBUTE Cisco-Pre-Output-Packets 193 integer Cisco
-ATTRIBUTE Cisco-Maximum-Time 194 integer Cisco
-ATTRIBUTE Cisco-Disconnect-Cause 195 integer Cisco
-ATTRIBUTE Cisco-Data-Rate 197 integer Cisco
-ATTRIBUTE Cisco-PreSession-Time 198 integer Cisco
-ATTRIBUTE Cisco-PW-Lifetime 208 integer Cisco
-ATTRIBUTE Cisco-IP-Direct 209 integer Cisco
-ATTRIBUTE Cisco-PPP-VJ-Slot-Comp 210 integer Cisco
-ATTRIBUTE Cisco-PPP-Async-Map 212 integer Cisco
-ATTRIBUTE Cisco-IP-Pool-Definition 217 string Cisco
-ATTRIBUTE Cisco-Assign-IP-Pool 218 integer Cisco
-ATTRIBUTE Cisco-Route-IP 228 integer Cisco
-ATTRIBUTE Cisco-Link-Compression 233 integer Cisco
-ATTRIBUTE Cisco-Target-Util 234 integer Cisco
-ATTRIBUTE Cisco-Maximum-Channels 235 integer Cisco
-ATTRIBUTE Cisco-Data-Filter 242 integer Cisco
-ATTRIBUTE Cisco-Call-Filter 243 integer Cisco
-ATTRIBUTE Cisco-Idle-Limit 244 integer Cisco
-ATTRIBUTE Cisco-Account-Info 250 string Cisco
-ATTRIBUTE Cisco-Service-Info 251 string Cisco
-ATTRIBUTE Cisco-Command-Code 252 string Cisco
-ATTRIBUTE Cisco-Control-Info 253 string Cisco
-ATTRIBUTE Cisco-Xmit-Rate 255 integer Cisco
+ATTRIBUTE Cisco-Multilink-ID 187 integer
+ATTRIBUTE Cisco-Num-In-Multilink 188 integer
+ATTRIBUTE Cisco-Pre-Input-Octets 190 integer
+ATTRIBUTE Cisco-Pre-Output-Octets 191 integer
+ATTRIBUTE Cisco-Pre-Input-Packets 192 integer
+ATTRIBUTE Cisco-Pre-Output-Packets 193 integer
+ATTRIBUTE Cisco-Maximum-Time 194 integer
+ATTRIBUTE Cisco-Disconnect-Cause 195 integer
+ATTRIBUTE Cisco-Data-Rate 197 integer
+ATTRIBUTE Cisco-PreSession-Time 198 integer
+ATTRIBUTE Cisco-PW-Lifetime 208 integer
+ATTRIBUTE Cisco-IP-Direct 209 integer
+ATTRIBUTE Cisco-PPP-VJ-Slot-Comp 210 integer
+ATTRIBUTE Cisco-PPP-Async-Map 212 integer
+ATTRIBUTE Cisco-IP-Pool-Definition 217 string
+ATTRIBUTE Cisco-Assign-IP-Pool 218 integer
+ATTRIBUTE Cisco-Route-IP 228 integer
+ATTRIBUTE Cisco-Link-Compression 233 integer
+ATTRIBUTE Cisco-Target-Util 234 integer
+ATTRIBUTE Cisco-Maximum-Channels 235 integer
+ATTRIBUTE Cisco-Data-Filter 242 integer
+ATTRIBUTE Cisco-Call-Filter 243 integer
+ATTRIBUTE Cisco-Idle-Limit 244 integer
+ATTRIBUTE Cisco-Account-Info 250 string
+ATTRIBUTE Cisco-Service-Info 251 string
+ATTRIBUTE Cisco-Command-Code 252 string
+ATTRIBUTE Cisco-Control-Info 253 string
+ATTRIBUTE Cisco-Xmit-Rate 255 integer
+
+VALUE Cisco-Disconnect-Cause Unknown 2
+VALUE Cisco-Disconnect-Cause CLID-Authentication-Failure 4
+VALUE Cisco-Disconnect-Cause No-Carrier 10
+VALUE Cisco-Disconnect-Cause Lost-Carrier 11
+VALUE Cisco-Disconnect-Cause No-Detected-Result-Codes 12
+VALUE Cisco-Disconnect-Cause User-Ends-Session 20
+VALUE Cisco-Disconnect-Cause Idle-Timeout 21
+VALUE Cisco-Disconnect-Cause Exit-Telnet-Session 22
+VALUE Cisco-Disconnect-Cause No-Remote-IP-Addr 23
+VALUE Cisco-Disconnect-Cause Exit-Raw-TCP 24
+VALUE Cisco-Disconnect-Cause Password-Fail 25
+VALUE Cisco-Disconnect-Cause Raw-TCP-Disabled 26
+VALUE Cisco-Disconnect-Cause Control-C-Detected 27
+VALUE Cisco-Disconnect-Cause EXEC-Program-Destroyed 28
+VALUE Cisco-Disconnect-Cause Timeout-PPP-LCP 40
+VALUE Cisco-Disconnect-Cause Failed-PPP-LCP-Negotiation 41
+VALUE Cisco-Disconnect-Cause Failed-PPP-PAP-Auth-Fail 42
+VALUE Cisco-Disconnect-Cause Failed-PPP-CHAP-Auth 43
+VALUE Cisco-Disconnect-Cause Failed-PPP-Remote-Auth 44
+VALUE Cisco-Disconnect-Cause PPP-Remote-Terminate 45
+VALUE Cisco-Disconnect-Cause PPP-Closed-Event 46
+VALUE Cisco-Disconnect-Cause Session-Timeout 100
+VALUE Cisco-Disconnect-Cause Session-Failed-Security 101
+VALUE Cisco-Disconnect-Cause Session-End-Callback 102
+VALUE Cisco-Disconnect-Cause Invalid-Protocol 120
-VALUE Cisco-Disconnect-Cause Unknown 2
-VALUE Cisco-Disconnect-Cause CLID-Authentication-Failure 4
-VALUE Cisco-Disconnect-Cause No-Carrier 10
-VALUE Cisco-Disconnect-Cause Lost-Carrier 11
-VALUE Cisco-Disconnect-Cause No-Detected-Result-Codes 12
-VALUE Cisco-Disconnect-Cause User-Ends-Session 20
-VALUE Cisco-Disconnect-Cause Idle-Timeout 21
-VALUE Cisco-Disconnect-Cause Exit-Telnet-Session 22
-VALUE Cisco-Disconnect-Cause No-Remote-IP-Addr 23
-VALUE Cisco-Disconnect-Cause Exit-Raw-TCP 24
-VALUE Cisco-Disconnect-Cause Password-Fail 25
-VALUE Cisco-Disconnect-Cause Raw-TCP-Disabled 26
-VALUE Cisco-Disconnect-Cause Control-C-Detected 27
-VALUE Cisco-Disconnect-Cause EXEC-Program-Destroyed 28
-VALUE Cisco-Disconnect-Cause Timeout-PPP-LCP 40
-VALUE Cisco-Disconnect-Cause Failed-PPP-LCP-Negotiation 41
-VALUE Cisco-Disconnect-Cause Failed-PPP-PAP-Auth-Fail 42
-VALUE Cisco-Disconnect-Cause Failed-PPP-CHAP-Auth 43
-VALUE Cisco-Disconnect-Cause Failed-PPP-Remote-Auth 44
-VALUE Cisco-Disconnect-Cause PPP-Remote-Terminate 45
-VALUE Cisco-Disconnect-Cause PPP-Closed-Event 46
-VALUE Cisco-Disconnect-Cause Session-Timeout 100
-VALUE Cisco-Disconnect-Cause Session-Failed-Security 101
-VALUE Cisco-Disconnect-Cause Session-End-Callback 102
-VALUE Cisco-Disconnect-Cause Invalid-Protocol 120
+END-VENDOR Cisco
+# -*- text -*-
#
-# Cisco Building Broadband Service Manager Dictionary
+# Cisco Building Broadband Service Manager Dictionary
#
# http://www.cisco.com/univercd/cc/td/doc/product/access/acs_soft/csacs4nt/csnt30/user/ad.htm
#
# $Id$
#
-VENDOR Cisco-BBSM 5263
+VENDOR Cisco-BBSM 5263
-BEGIN-VENDOR Cisco-BBSM
-ATTRIBUTE CBBSM-Bandwidth 1 integer
+BEGIN-VENDOR Cisco-BBSM
+ATTRIBUTE CBBSM-Bandwidth 1 integer
END-VENDOR Cisco-BBSM
+# -*- text -*-
#
# Cisco VPN 3000 Concentrator Dictionary
#
#
# $Id$
#
-VENDOR Cisco-VPN3000 3076
+VENDOR Cisco-VPN3000 3076
-BEGIN-VENDOR Cisco-VPN3000
+BEGIN-VENDOR Cisco-VPN3000
ATTRIBUTE CVPN3000-Access-Hours 1 string
ATTRIBUTE CVPN3000-Simultaneous-Logins 2 integer
+ATTRIBUTE CVPN3000-Min-Password-Length 3 integer
+ATTRIBUTE CVPN3000-Allow-Alpha-Only-Passwords 4 integer
ATTRIBUTE CVPN3000-Primary-DNS 5 ipaddr
ATTRIBUTE CVPN3000-Secondary-DNS 6 ipaddr
ATTRIBUTE CVPN3000-Primary-WINS 7 ipaddr
ATTRIBUTE CVPN3000-Partition-Max-Sessions 132 integer
ATTRIBUTE CVPN3000-Partition-Mobile-IP-Key 133 string
ATTRIBUTE CVPN3000-Partition-Mobile-IP-Address 134 ipaddr
-ATTRIBUTE CVPN3000-Partition-Mobile-IP-SPI 136 integer
+ATTRIBUTE CVPN3000-Partition-Mobile-IP-SPI 135 integer
ATTRIBUTE CVPN3000-Strip-Realm 136 integer
+ATTRIBUTE CVPN3000-Group-Name 137 integer
+
+VALUE CVPN3000-Allow-Alpha-Only-Passwords Disallow 0
+VALUE CVPN3000-Allow-Alpha-Only-Passwords Allow 1
+
+VALUE CVPN3000-SEP-Card-Assignment SEP1 1
+VALUE CVPN3000-SEP-Card-Assignment SEP2 2
+VALUE CVPN3000-SEP-Card-Assignment SEP3 4
+VALUE CVPN3000-SEP-Card-Assignment SEP4 8
+VALUE CVPN3000-SEP-Card-Assignment Any-SEP 15
+
+VALUE CVPN3000-Priority-On-SEP High 1
+VALUE CVPN3000-Priority-On-SEP Med-High 2
+VALUE CVPN3000-Priority-On-SEP Medium 3
+VALUE CVPN3000-Priority-On-SEP Med-Low 4
+VALUE CVPN3000-Priority-On-SEP Low 5
+
+VALUE CVPN3000-Tunneling-Protocols PPTP 1
+VALUE CVPN3000-Tunneling-Protocols L2TP 2
+VALUE CVPN3000-Tunneling-Protocols IPSec 4
+VALUE CVPN3000-Tunneling-Protocols PPTP-and-IPSec 5
+VALUE CVPN3000-Tunneling-Protocols L2TP/IPSec 8
+VALUE CVPN3000-Tunneling-Protocols All 15
+
+VALUE CVPN3000-IPSec-Authentication None 0
+VALUE CVPN3000-IPSec-Authentication RADIUS 1
+VALUE CVPN3000-IPSec-Authentication LDAP 2
+VALUE CVPN3000-IPSec-Authentication NTDomain 3
+VALUE CVPN3000-IPSec-Authentication SDI 4
+VALUE CVPN3000-IPSec-Authentication Internal 5
+
+VALUE CVPN3000-IPSec-Allow-Passwd-Store Disallow 0
+VALUE CVPN3000-IPSec-Allow-Passwd-Store Allow 1
+
+VALUE CVPN3000-Use-Client-Address Disallow 0
+VALUE CVPN3000-Use-Client-Address Allow 1
+
+VALUE CVPN3000-PPTP-Min-Auth-Protocol PAP 1
+VALUE CVPN3000-PPTP-Min-Auth-Protocol CHAP 2
+VALUE CVPN3000-PPTP-Min-Auth-Protocol EAP-MD5 4
+VALUE CVPN3000-PPTP-Min-Auth-Protocol EAP-GTC 8
+VALUE CVPN3000-PPTP-Min-Auth-Protocol EAP-TLS 16
+VALUE CVPN3000-PPTP-Min-Auth-Protocol MSCHAPv1 32
+VALUE CVPN3000-PPTP-Min-Auth-Protocol MSCHAPv2 64
+VALUE CVPN3000-PPTP-Min-Auth-Protocol Default 102
+
+VALUE CVPN3000-L2TP-Min-Auth-Protocol PAP 1
+VALUE CVPN3000-L2TP-Min-Auth-Protocol CHAP 2
+VALUE CVPN3000-L2TP-Min-Auth-Protocol EAP-MD5 4
+VALUE CVPN3000-L2TP-Min-Auth-Protocol EAP-GTC 8
+VALUE CVPN3000-L2TP-Min-Auth-Protocol EAP-TLS 16
+VALUE CVPN3000-L2TP-Min-Auth-Protocol MSCHAPv1 32
+VALUE CVPN3000-L2TP-Min-Auth-Protocol MSCHAPv2 64
+VALUE CVPN3000-L2TP-Min-Auth-Protocol Default 102
+
+VALUE CVPN3000-PPTP-Encryption PPTP-40bit 2
+VALUE CVPN3000-PPTP-Encryption PPTP-40-Encryption-Req 3
+VALUE CVPN3000-PPTP-Encryption PPTP-128 4
+VALUE CVPN3000-PPTP-Encryption PPTP-128-Encryption-Req 5
+VALUE CVPN3000-PPTP-Encryption PPTP-40-or-128 6
+VALUE CVPN3000-PPTP-Encryption PPTP-40-or-128-Encry-Req 7
+VALUE CVPN3000-PPTP-Encryption PPTP-40-Stateless-Req 10
+VALUE CVPN3000-PPTP-Encryption PPTP-40-Enc/Stateless-Req 11
+VALUE CVPN3000-PPTP-Encryption PPTP-128-Stateless-Req 12
+VALUE CVPN3000-PPTP-Encryption PPTP-128-Enc/Stateless-Req 13
+VALUE CVPN3000-PPTP-Encryption PPTP-40/128-Stateless-Req 14
+VALUE CVPN3000-PPTP-Encryption PPTP-40/128-Enc/Statls-Req 15
+
+VALUE CVPN3000-L2TP-Encryption L2TP-40bit 2
+VALUE CVPN3000-L2TP-Encryption L2TP-40-Encryption-Req 3
+VALUE CVPN3000-L2TP-Encryption L2TP-128 4
+VALUE CVPN3000-L2TP-Encryption L2TP-128-Encryption-Req 5
+VALUE CVPN3000-L2TP-Encryption L2TP-40-or-128 6
+VALUE CVPN3000-L2TP-Encryption L2TP-40-or-128-Encry-Req 7
+VALUE CVPN3000-L2TP-Encryption L2TP-40-Stateless-Req 10
+VALUE CVPN3000-L2TP-Encryption L2TP-40-Enc/Stateless-Req 11
+VALUE CVPN3000-L2TP-Encryption L2TP-128-Stateless-Req 12
+VALUE CVPN3000-L2TP-Encryption L2TP-128-Enc/Stateless-Req 13
+VALUE CVPN3000-L2TP-Encryption L2TP-40/128-Stateless-Req 14
+VALUE CVPN3000-L2TP-Encryption L2TP-40/128-Enc/Statls-Req 15
+
+VALUE CVPN3000-Auth-Server-Type First-Active-Server 0
+VALUE CVPN3000-Auth-Server-Type RADIUS 1
+VALUE CVPN3000-Auth-Server-Type LDAP 2
+VALUE CVPN3000-Auth-Server-Type NT 3
+VALUE CVPN3000-Auth-Server-Type SDI 4
+VALUE CVPN3000-Auth-Server-Type Internal 5
+
+VALUE CVPN3000-IPSec-LTL-Keepalives OFF 0
+VALUE CVPN3000-IPSec-LTL-Keepalives ON 1
+
+VALUE CVPN3000-IPSec-Tunnel-Type LAN-to-LAN 1
+VALUE CVPN3000-IPSec-Tunnel-Type Remote-Access 2
+
+VALUE CVPN3000-IPSec-Mode-Config ON 1
+VALUE CVPN3000-IPSec-Mode-Config OFF 0
+
+VALUE CVPN3000-IPSec-User-Group-Lock OFF 0
+VALUE CVPN3000-IPSec-User-Group-Lock ON 1
+
+VALUE CVPN3000-IPSec-Over-UDP OFF 0
+VALUE CVPN3000-IPSec-Over-UDP ON 1
+
+VALUE CVPN3000-Strip-Realm FALSE 0
+VALUE CVPN3000-Strip-Realm TRUE 1
END-VENDOR Cisco-VPN3000
+# -*- text -*-
#
# Cisco VPN 5000 Concentrator Dictionary
#
#
# $Id$
#
-VENDOR Cisco-VPN5000 255
+VENDOR Cisco-VPN5000 255
-BEGIN-VENDOR Cisco-VPN5000
+BEGIN-VENDOR Cisco-VPN5000
ATTRIBUTE CVPN5000-Tunnel-Throughput 1 integer
ATTRIBUTE CVPN5000-Client-Assigned-IP 2 string
ATTRIBUTE CVPN5000-Client-Real-IP 3 string
+# -*- text -*-
# Colubris dictionary - dictionary.colubris
#
-# Enable by putting the line "$INCLUDE dictionary.colubris" into
-# the main dictionary file.
-#
-#
-VENDOR Colubris 8744
+VENDOR Colubris 8744
#
# Vendor-specific attributes
#
-ATTRIBUTE Colubris-AVPair 0 string Colubris
+BEGIN-VENDOR Colubris
+
+ATTRIBUTE Colubris-AVPair 0 string
+ATTRIBUTE Colubris-Intercept 1 integer
+
+END-VENDOR Colubris
-VALUE Service-Type Sip-session 12
+# -*- text -*-
+VALUE Service-Type Sip-session 12
# Columbia University VSAs, from:
#
#
# $Id$
#
-VENDOR Columbia-University 11862
+VENDOR Columbia-University 11862
-ATTRIBUTE Sip-Method 0 integer Columbia-University
-ATTRIBUTE Sip-From 1 string Columbia-University
-ATTRIBUTE Sip-To 2 string Columbia-University
-ATTRIBUTE Sip-Translated-Request-URI 4 string Columbia-University
+BEGIN-VENDOR Columbia-University
-VALUE Sip-Method INVITE 0
-VALUE Sip-Method BYE 1
-VALUE Sip-Method REGISTER 2
-VALUE Sip-Method OTHER 3
+ATTRIBUTE Sip-Method 0 integer
+ATTRIBUTE Sip-From 1 string
+ATTRIBUTE Sip-To 2 string
+ATTRIBUTE Sip-Translated-Request-URI 4 string
+
+VALUE Sip-Method INVITE 0
+VALUE Sip-Method BYE 1
+VALUE Sip-Method REGISTER 2
+VALUE Sip-Method OTHER 3
+
+END-VENDOR Columbia-University
+# -*- text -*-
#
# Obsolete names for backwards compatibility with older users files.
# Move the $INCLUDE in the main dictionary file to the end if you want
# these names to be used in the "details" logfile.
#
-ATTRIBUTE Password 2 string encrypt=1
-ATTRIBUTE Client-Id 4 ipaddr
-ATTRIBUTE Client-Port-Id 5 integer
-ATTRIBUTE User-Service-Type 6 integer
-ATTRIBUTE Framed-Address 8 ipaddr
-ATTRIBUTE Framed-Netmask 9 ipaddr
-ATTRIBUTE Framed-Filter-Id 11 string
-ATTRIBUTE Login-Host 14 ipaddr
-ATTRIBUTE Login-Port 16 integer
-ATTRIBUTE Old-Password 17 string
-ATTRIBUTE Port-Message 18 string
-ATTRIBUTE Dialback-No 19 string
-ATTRIBUTE Dialback-Name 20 string
-ATTRIBUTE Challenge-State 24 string
-VALUE Framed-Compression Van-Jacobsen-TCP-IP 1
-VALUE Framed-Compression VJ-TCP-IP 1
-VALUE Service-Type Shell-User 6
-VALUE Auth-Type Unix 1
-VALUE Service-Type Dialback-Login-User 3
-VALUE Service-Type Dialback-Framed-User 4
+ATTRIBUTE Password 2 string encrypt=1
+ATTRIBUTE Client-Id 4 ipaddr
+ATTRIBUTE Client-Port-Id 5 integer
+ATTRIBUTE User-Service-Type 6 integer
+ATTRIBUTE Framed-Address 8 ipaddr
+ATTRIBUTE Framed-Netmask 9 ipaddr
+ATTRIBUTE Framed-Filter-Id 11 string
+ATTRIBUTE Login-Host 14 ipaddr
+ATTRIBUTE Login-Port 16 integer
+ATTRIBUTE Old-Password 17 string
+ATTRIBUTE Port-Message 18 string
+ATTRIBUTE Dialback-No 19 string
+ATTRIBUTE Dialback-Name 20 string
+ATTRIBUTE Challenge-State 24 string
+VALUE Framed-Compression Van-Jacobsen-TCP-IP 1
+VALUE Framed-Compression VJ-TCP-IP 1
+VALUE Service-Type Shell-User 6
+VALUE Auth-Type Unix 1
+VALUE Service-Type Dialback-Login-User 3
+VALUE Service-Type Dialback-Framed-User 4
#
# For compatibility with MERIT users files.
#
-ATTRIBUTE Login-Callback-Number 19 string
-ATTRIBUTE Framed-Callback-Id 20 string
-ATTRIBUTE Client-Port-DNIS 30 string
-ATTRIBUTE Caller-ID 31 string
-VALUE Service-Type Login 1
-VALUE Service-Type Framed 2
-VALUE Service-Type Callback-Login 3
-VALUE Service-Type Callback-Framed 4
-VALUE Service-Type Exec-User 7
+ATTRIBUTE Login-Callback-Number 19 string
+ATTRIBUTE Framed-Callback-Id 20 string
+ATTRIBUTE Client-Port-DNIS 30 string
+ATTRIBUTE Caller-ID 31 string
+VALUE Service-Type Login 1
+VALUE Service-Type Framed 2
+VALUE Service-Type Callback-Login 3
+VALUE Service-Type Callback-Framed 4
+VALUE Service-Type Exec-User 7
#
# For compatibility with ESVA RADIUS, Old Cistron RADIUS
#
-ATTRIBUTE Session 1034 integer
-ATTRIBUTE User-Name-Is-Star 1035 integer
-VALUE User-Name-Is-Star No 0
-VALUE User-Name-Is-Star Yes 1
-VALUE Auth-Type None 254
-ATTRIBUTE PostAuth-Type 1014 integer
-VALUE PostAuth-Type Local 0
+ATTRIBUTE Session 1034 integer
+ATTRIBUTE User-Name-Is-Star 1035 integer
+VALUE User-Name-Is-Star No 0
+VALUE User-Name-Is-Star Yes 1
+VALUE Auth-Type None 254
+ATTRIBUTE PostAuth-Type 1014 integer
+VALUE PostAuth-Type Local 0
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Cosine IPSX Dictionary
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Cosine 3085
+
+BEGIN-VENDOR Cosine
+
+ATTRIBUTE Cosine-Connection-Profile-Name 1 string
+ATTRIBUTE Cosine-Enterprise-ID 2 string
+ATTRIBUTE Cosine-Address-Pool-Name 3 string
+ATTRIBUTE Cosine-DS-Byte 4 integer
+ATTRIBUTE Cosine-VPI-VCI 5 octets
+ATTRIBUTE Cosine-DLCI 6 integer
+ATTRIBUTE Cosine-LNS-IP-Address 7 ipaddr
+ATTRIBUTE Cosine-CLI-User-Permission-ID 8 string
+
+END-VENDOR Cosine
--- /dev/null
+# As defined in draft-sterman-aaa-sip-00.txt
+ATTRIBUTE Digest-Response 206 string
+ATTRIBUTE Digest-Attributes 207 octets # stupid format
+
+BEGIN-SUB-ATTR Digest-Attributes
+ATTRIBUTE Digest-Realm 1 string
+ATTRIBUTE Digest-Nonce 2 string
+ATTRIBUTE Digest-Method 3 string
+ATTRIBUTE Digest-URI 4 string
+ATTRIBUTE Digest-QOP 5 string
+ATTRIBUTE Digest-Algorithm 6 string
+ATTRIBUTE Digest-Body-Digest 7 string
+ATTRIBUTE Digest-CNonce 8 string
+ATTRIBUTE Digest-Nonce-Count 9 string
+ATTRIBUTE Digest-User-Name 10 string
+END-SUB-ATTR
--- /dev/null
+# -*- text -*-
+#
+# dictionary.Epygi
+#
+
+VENDOR Epygi 16459
+
+#
+# Standard attribute
+#
+BEGIN-VENDOR Epygi
+
+ATTRIBUTE Epygi-AVPair 1 string
+ATTRIBUTE Epygi-NAS-Port 2 string
+
+#
+# Voice over IP attributes.
+#
+ATTRIBUTE Epygi-h323-remote-address 23 string
+ATTRIBUTE Epygi-h323-conf-id 24 string
+ATTRIBUTE Epygi-h323-setup-time 25 string
+ATTRIBUTE Epygi-h323-call-origin 26 string
+ATTRIBUTE Epygi-h323-call-type 27 string
+ATTRIBUTE Epygi-h323-connect-time 28 string
+ATTRIBUTE Epygi-h323-disconnect-time 29 string
+ATTRIBUTE Epygi-h323-disconnect-cause 30 string
+ATTRIBUTE Epygi-h323-voice-quality 31 string
+ATTRIBUTE Epygi-h323-gw-id 33 string
+ATTRIBUTE Epygi-h323-incoming-conf-id 35 string
+
+ATTRIBUTE Epygi-h323-credit-amount 101 string
+ATTRIBUTE Epygi-h323-credit-time 102 string
+ATTRIBUTE Epygi-h323-return-code 103 string
+ATTRIBUTE Epygi-h323-prompt-id 104 string
+ATTRIBUTE Epygi-h323-time-and-day 105 string
+ATTRIBUTE Epygi-h323-redirect-number 106 string
+ATTRIBUTE Epygi-h323-preferred-lang 107 string
+ATTRIBUTE Epygi-h323-redirect-ip-address 108 string
+ATTRIBUTE Epygi-h323-billing-model 109 string
+ATTRIBUTE Epygi-h323-currency 110 string
+
+ATTRIBUTE Epygi-RegExpDate 150 string
+ATTRIBUTE Epygi-FiadID 151 string
+ATTRIBUTE Epygi-PortID 152 string
+ATTRIBUTE Epygi-AccessType 153 string
+ATTRIBUTE Epygi-CallInfo 154 string
+
+ATTRIBUTE Epygi-OrigCallID 170 string
+ATTRIBUTE Epygi-ParentCallID 171 string
+ATTRIBUTE Epygi-CallType 172 integer
+ATTRIBUTE Epygi-DeviceName 173 string
+ATTRIBUTE Epygi-InterfaceName 174 integer
+ATTRIBUTE Epygi-InterfaceNumber 175 integer
+ATTRIBUTE Epygi-TimeslotNumber 176 integer
+ATTRIBUTE Epygi-OrigIpAddr 177 integer
+ATTRIBUTE Epygi-DestIpAddr 178 integer
+ATTRIBUTE Epygi-OrigIpPort 179 integer
+ATTRIBUTE Epygi-DestIpPort 180 integer
+ATTRIBUTE Epygi-CallingPartyNumber 181 string
+ATTRIBUTE Epygi-CalledPartyNumber 182 string
+ATTRIBUTE Epygi-DateTimeOrigination 183 integer
+ATTRIBUTE Epygi-DateTimeConnect 184 integer
+ATTRIBUTE Epygi-DateTimeDisconnect 185 integer
+ATTRIBUTE Epygi-Duration 186 integer
+ATTRIBUTE Epygi-OutSourceRTP_IP 187 integer
+ATTRIBUTE Epygi-OutDestRTP_IP 188 integer
+ATTRIBUTE Epygi-InSourceRTP_IP 189 integer
+ATTRIBUTE Epygi-InDestRTP_IP 190 integer
+ATTRIBUTE Epygi-OutSourceRTP_port 191 integer
+ATTRIBUTE Epygi-OutDestRTP_port 192 integer
+ATTRIBUTE Epygi-InSourceRTP_port 193 integer
+ATTRIBUTE Epygi-InDestRTP_port 194 integer
+ATTRIBUTE Epygi-CallRedirectReason 195 integer
+ATTRIBUTE Epygi-CallDisconnectReason 196 integer
+ATTRIBUTE Epygi-OutRTP_Payload 197 integer
+ATTRIBUTE Epygi-OutRTP_PacketSize 198 integer
+ATTRIBUTE Epygi-OutRTP_Packets 199 integer
+ATTRIBUTE Epygi-OutRTP_Octets 200 integer
+ATTRIBUTE Epygi-InRTP_Payload 201 integer
+ATTRIBUTE Epygi-InRTP_PacketSize 202 integer
+ATTRIBUTE Epygi-InRTP_Packets 203 integer
+ATTRIBUTE Epygi-InRTP_Octets 204 integer
+ATTRIBUTE Epygi-InRTP_PacketsLost 205 integer
+ATTRIBUTE Epygi-InRTP_PacketsDupl 206 integer
+ATTRIBUTE Epygi-InRTP_Jitter 207 integer
+ATTRIBUTE Epygi-InRTP_Latency 208 integer
+
+VALUE Epygi-CallType Internal 0
+VALUE Epygi-CallType SIP 1
+VALUE Epygi-CallType H.323 2
+VALUE Epygi-CallType FXO 3
+VALUE Epygi-CallType T1-E1-CAS 4
+VALUE Epygi-CallType T1-E1-CCS 5
+VALUE Epygi-CallType ISDN-PRI 6
+
+VALUE Epygi-InterfaceName Ethernet 0
+VALUE Epygi-InterfaceName FXO 1
+VALUE Epygi-InterfaceName T1-E1-User 2
+VALUE Epygi-InterfaceName T1-E1-Network 3
+VALUE Epygi-InterfaceName ISDN 4
+
+VALUE Epygi-CallRedirectReason No-Reason 0
+VALUE Epygi-CallRedirectReason Call-Forward-Uncondit 1
+VALUE Epygi-CallRedirectReason Call-Forward-Busy 2
+VALUE Epygi-CallRedirectReason Call-Forward-NoAnswer 3
+VALUE Epygi-CallRedirectReason Call-Tranfer 4
+VALUE Epygi-CallRedirectReason Call-Park 5
+VALUE Epygi-CallRedirectReason Call-Pickup 6
+VALUE Epygi-CallRedirectReason ManyExtension-Ringing 7
+VALUE Epygi-CallRedirectReason Hunt-Group 8
+
+VALUE Epygi-CallDisconnectReason Call-Is-Redirected 0
+VALUE Epygi-CallDisconnectReason Call-Origin-OnHook 1
+VALUE Epygi-CallDisconnectReason Call-Temin-OnHook 2
+VALUE Epygi-CallDisconnectReason Disconected-by-CAC 3
+VALUE Epygi-CallDisconnectReason Other 4
+
+END-VENDOR Epygi
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Ericsson dictionary
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Ericsson 193
+
+BEGIN-VENDOR Ericsson
+
+ATTRIBUTE Ericsson-ViG-Balance 3 integer
+ATTRIBUTE Ericsson-ViG-Codec 4 integer
+ATTRIBUTE Ericsson-ViG-Currency 5 string
+ATTRIBUTE Ericsson-ViG-Currency-Quote 6 string
+ATTRIBUTE Ericsson-ViG-Endpoint-Type 8 integer
+ATTRIBUTE Ericsson-ViG-Sequence-Number 9 integer
+ATTRIBUTE Ericsson-ViG-Access-Agent-IP-Address 11 ipaddr
+ATTRIBUTE Ericsson-ViG-QoS-Class 12 integer
+
+#
+# These next two attributes look to be similar to Digest-Response (206) and
+# Digest-Attributes (207)
+#
+ATTRIBUTE Ericsson-ViG-Digest-Response 14 string
+ATTRIBUTE Ericsson-ViG-Digest-Attributes 15 octets
+
+ATTRIBUTE Ericsson-ViG-Business-Agreement-Name 16 string
+ATTRIBUTE Ericsson-ViG-Call-Role 17 integer
+ATTRIBUTE Ericsson-ViG-Remote-SK-UA-IP-Address 20 ipaddr
+ATTRIBUTE Ericsson-ViG-Site 23 string
+ATTRIBUTE Ericsson-ViG-TTL-relative 32 integer
+ATTRIBUTE Ericsson-ViG-Account-error-reason 33 integer
+ATTRIBUTE Ericsson-ViG-Layer-identity 34 integer
+ATTRIBUTE Ericsson-ViG-Major-protocol-version 35 integer
+ATTRIBUTE Ericsson-ViG-Minor-protocol-version 36 integer
+ATTRIBUTE Ericsson-ViG-Authentication-type 37 integer
+ATTRIBUTE Ericsson-ViG-Trusted-access 38 integer
+ATTRIBUTE Ericsson-ViG-User-name 39 string
+ATTRIBUTE Ericsson-ViG-Global-unique-call-ID 40 string
+ATTRIBUTE Ericsson-ViG-Global-unique-service-ID 41 string
+ATTRIBUTE Ericsson-ViG-Interim-interval 42 integer
+ATTRIBUTE Ericsson-ViG-Alive-Indicator 43 integer
+ATTRIBUTE Ericsson-ViG-TTL-Absolute 44 integer
+ATTRIBUTE Ericsson-ViG-TTL-Start-Event 45 integer
+ATTRIBUTE Ericsson-ViG-SK-IP-address 46 ipaddr
+ATTRIBUTE Ericsson-ViG-UA-IP-address 47 ipaddr
+ATTRIBUTE Ericsson-ViG-SA-IP-address 48 ipaddr
+ATTRIBUTE Ericsson-ViG-Calling-e164-number 49 string
+ATTRIBUTE Ericsson-ViG-Calling-H323Id 50 string
+ATTRIBUTE Ericsson-ViG-Calling-Email-address 51 string
+ATTRIBUTE Ericsson-ViG-Dialled-e164-number 52 string
+ATTRIBUTE Ericsson-ViG-Dialled-H323Id 53 string
+ATTRIBUTE Ericsson-ViG-Dialled-Email-address 54 string
+ATTRIBUTE Ericsson-ViG-Routed-e164-number 55 string
+ATTRIBUTE Ericsson-ViG-Routed-H323Id 56 string
+ATTRIBUTE Ericsson-ViG-Routed-Email-address 57 string
+ATTRIBUTE Ericsson-ViG-SiteKeeper-name 58 string
+ATTRIBUTE Ericsson-ViG-Access-Group-name 59 string
+ATTRIBUTE Ericsson-ViG-Access-Agent-name 60 string
+ATTRIBUTE Ericsson-ViG-User-agent-group-name 61 string
+ATTRIBUTE Ericsson-ViG-User-agent-name 62 string
+ATTRIBUTE Ericsson-ViG-Routing-tariff 63 integer
+ATTRIBUTE Ericsson-ViG-Re-selection-counter 64 integer
+ATTRIBUTE Ericsson-ViG-CPN-digits 65 string
+ATTRIBUTE Ericsson-ViG-CPN-TON 66 integer
+ATTRIBUTE Ericsson-ViG-CPN-NP 67 integer
+ATTRIBUTE Ericsson-ViG-CPN-PI 68 integer
+ATTRIBUTE Ericsson-ViG-CPN-SI 69 integer
+ATTRIBUTE Ericsson-ViG-Dialled-num-digits 70 string
+ATTRIBUTE Ericsson-ViG-Dialled-num-TON 71 integer
+ATTRIBUTE Ericsson-ViG-Dialled-num-NP 72 integer
+ATTRIBUTE Ericsson-ViG-Routing-num-digits 73 string
+ATTRIBUTE Ericsson-ViG-Routing-num-TON 74 integer
+ATTRIBUTE Ericsson-ViG-Routing-num-NP 75 integer
+ATTRIBUTE Ericsson-ViG-Redirecting-num-digits 76 string
+ATTRIBUTE Ericsson-ViG-Redirecting-num-TON 77 integer
+ATTRIBUTE Ericsson-ViG-Redirecting-num-NP 78 integer
+ATTRIBUTE Ericsson-ViG-Redirecting-num-PI 79 integer
+ATTRIBUTE Ericsson-ViG-Redirecting-num-RFD 80 integer
+ATTRIBUTE Ericsson-ViG-Time-stamp-UTC 81 integer
+ATTRIBUTE Ericsson-ViG-Time-stamp-UTC 81 integer
+ATTRIBUTE Ericsson-ViG-Time-stamp-TZ 82 integer
+ATTRIBUTE Ericsson-ViG-Time-stamp-DST 83 integer
+ATTRIBUTE Ericsson-ViG-Session-routing-duration 84 integer
+ATTRIBUTE Ericsson-ViG-Session-ringing-duration 85 integer
+ATTRIBUTE Ericsson-ViG-Access-type 86 integer
+ATTRIBUTE Ericsson-ViG-Requested-bandwidth 87 integer
+ATTRIBUTE Ericsson-ViG-Allowed-bandwidth 88 integer
+ATTRIBUTE Ericsson-ViG-Media-channel-count 89 integer
+ATTRIBUTE Ericsson-ViG-Voice-media-rec-forward 90 string
+ATTRIBUTE Ericsson-ViG-Voice-media-rec-backward 91 string
+ATTRIBUTE Ericsson-ViG-Video-media-rec-forward 92 string
+ATTRIBUTE Ericsson-ViG-Video-media-rec-backward 93 string
+ATTRIBUTE Ericsson-ViG-Fax-media-rec-forward 94 string
+ATTRIBUTE Ericsson-ViG-Fax-media-rec-backward 95 string
+ATTRIBUTE Ericsson-ViG-Data-media-rec-forward 96 string
+ATTRIBUTE Ericsson-ViG-Data-media-rec-backward 97 string
+ATTRIBUTE Ericsson-ViG-Charging-Case 98 integer
+ATTRIBUTE Ericsson-ViG-Rel-cause-coding-std 99 integer
+ATTRIBUTE Ericsson-ViG-Rel-cause-location 100 integer
+ATTRIBUTE Ericsson-ViG-Rel-cause-class 101 integer
+ATTRIBUTE Ericsson-ViG-Rel-cause-value 102 integer
+ATTRIBUTE Ericsson-ViG-Rel-reason 103 integer
+ATTRIBUTE Ericsson-ViG-Internal-Rel-reason-val 104 integer
+ATTRIBUTE Ericsson-ViG-Internal-Rel-reason-orig 105 integer
+ATTRIBUTE Ericsson-ViG-Service-ID 106 integer
+ATTRIBUTE Ericsson-ViG-User-ID 107 string
+ATTRIBUTE Ericsson-ViG-Service-Name 108 string
+ATTRIBUTE Ericsson-ViG-Test-Call-Indicator 109 integer
+ATTRIBUTE Ericsson-ViG-Test-Call-Indicator 109 integer
+ATTRIBUTE Ericsson-ViG-Emergency-Call-Indicator 110 integer
+ATTRIBUTE Ericsson-ViG-Calling-ID 111 string
+ATTRIBUTE Ericsson-ViG-Called-ID 112 string
+ATTRIBUTE Ericsson-ViG-Translated-ID 113 string
+ATTRIBUTE Ericsson-ViG-Calling-User-Group-ID 114 string
+ATTRIBUTE Ericsson-ViG-Calling-Usr-Sub-Group-ID 115 string
+ATTRIBUTE Ericsson-ViG-Called-Usr-Group-ID 116 string
+ATTRIBUTE Ericsson-ViG-Called-Usr-Sub-Group-ID 117 string
+ATTRIBUTE Ericsson-ViG-Terminal-Type 118 string
+ATTRIBUTE Ericsson-ViG-Service-Duration 119 integer
+ATTRIBUTE Ericsson-ViG-Service-Execution-Result 120 integer
+ATTRIBUTE Ericsson-ViG-Service-Exe-Rslt-Desc 121 string
+ATTRIBUTE Ericsson-ViG-Service-Description 122 string
+ATTRIBUTE Ericsson-ViG-Service-Specific-Info 123 string
+ATTRIBUTE Ericsson-ViG-Proxy-IP-Address 124 ipaddr
+ATTRIBUTE Ericsson-ViG-Auth-DataRequest 125 integer
+ATTRIBUTE Ericsson-ViG-IPT-Time-Stamp 126 integer
+ATTRIBUTE Ericsson-ViG-User-Name-Info 127 integer
+
+END-VENDOR Ericsson
+# -*- text -*-
#
# dictionary.erx
#
# Unisphere's broadband RAS
-# From Terje Krogdahl <tekr@nextra.com>
+# From Terje Krogdahl <tekr@nextra.com>
# Last touched by Paul Hampson <Paul.Hampson@Pobox.Com>
#
# Version: $Id$
#
# Juniper ERX dictionaries are available at:
+# http://www.juniper.net/techpubs/software/erx/junose700/unisphere7-0.dct
+# http://www.juniper.net/techpubs/software/erx/junose700/swconfig-broadband/html/radius-attributes.html
# http://www.juniper.net/techpubs/software/erx/junose52/unisphere5-2.dct
# http://www.juniper.net/techpubs/software/erx/erx50x/swconfig-broadband/html/radius-attributes.html
# (The below are from when it was the Unisphere ERX)
#
#
-VENDOR ERX 4874
+VENDOR ERX 4874
-ATTRIBUTE ERX-Virtual-Router-Name 1 string ERX
-ATTRIBUTE ERX-Address-Pool-Name 2 string ERX
-ATTRIBUTE ERX-Local-Loopback-Interface 3 string ERX
-ATTRIBUTE ERX-Primary-Dns 4 ipaddr ERX
-ATTRIBUTE ERX-Secondary-Dns 5 ipaddr ERX
-ATTRIBUTE ERX-Primary-Wins 6 ipaddr ERX
-ATTRIBUTE ERX-Secondary-Wins 7 ipaddr ERX
-ATTRIBUTE ERX-Tunnel-Virtual-Router 8 string ERX
-ATTRIBUTE ERX-Tunnel-Password 9 string ERX
-ATTRIBUTE ERX-Ingress-Policy-Name 10 string ERX
-ATTRIBUTE ERX-Egress-Policy-Name 11 string ERX
-ATTRIBUTE ERX-Ingress-Statistics 12 string ERX
-ATTRIBUTE ERX-Egress-Statistics 13 string ERX
-ATTRIBUTE ERX-Atm-Service-Category 14 integer ERX
-ATTRIBUTE ERX-Atm-PCR 15 integer ERX
-ATTRIBUTE ERX-Atm-SCR 16 integer ERX
-ATTRIBUTE ERX-Atm-MBS 17 integer ERX
-ATTRIBUTE ERX-Cli-Initial-Access-Level 18 string ERX
-ATTRIBUTE ERX-Cli-Allow-All-VR-Access 19 integer ERX
-ATTRIBUTE ERX-Alternate-Cli-Access-Level 20 string ERX
-ATTRIBUTE ERX-Alternate-Cli-Vrouter-Name 21 string ERX
-ATTRIBUTE ERX-Sa-Validate 22 integer ERX
-ATTRIBUTE ERX-Igmp-Enable 23 integer ERX
-ATTRIBUTE ERX-Pppoe-Description 24 string ERX
-ATTRIBUTE ERX-Redirect-VR-Name 25 string ERX
-ATTRIBUTE ERX-Qos-Profile-Name 26 string ERX
-ATTRIBUTE ERX-Pppoe-Max-Sessions 27 integer ERX
-ATTRIBUTE ERX-Pppoe-Url 28 string ERX
-ATTRIBUTE ERX-Qos-Profile-Interface-Type 29 integer ERX
-ATTRIBUTE ERX-Tunnel-Nas-Port-Method 30 integer ERX
-ATTRIBUTE ERX-Service-Bundle 31 string ERX
-ATTRIBUTE ERX-Tunnel-Tos 32 integer ERX
-ATTRIBUTE ERX-Tunnel-Maximum-Sessions 33 integer ERX
-ATTRIBUTE ERX-Framed-Ip-Route-Tag 34 string ERX
-ATTRIBUTE ERX-Dial-Out-Number 35 string ERX
-ATTRIBUTE ERX-PPP-Username 36 string ERX
-ATTRIBUTE ERX-PPP-Password 37 string ERX
-ATTRIBUTE ERX-PPP-Auth-Protocol 38 integer ERX
-ATTRIBUTE ERX-Minimum-BPS 39 integer ERX
-ATTRIBUTE ERX-Maximum-BPS 40 integer ERX
-ATTRIBUTE ERX-Bearer-Type 41 integer ERX
-ATTRIBUTE ERX-Input-Gigapkts 42 integer ERX
-ATTRIBUTE ERX-Output-Gigapkts 43 integer ERX
-ATTRIBUTE ERX-Tunnel-Interface-Id 44 string ERX
-ATTRIBUTE ERX-IpV6-Virtual-Router 45 string ERX
-ATTRIBUTE ERX-IpV6-Local-Interface 46 string ERX
-ATTRIBUTE ERX-Ipv6-Primary-Dns 47 string ERX
-ATTRIBUTE ERX-Ipv6-Secondary-Dns 48 string ERX
-ATTRIBUTE Sdx-Service-Name 49 string ERX
-ATTRIBUTE Sdx-Session-Volume-Quota 50 string ERX
-ATTRIBUTE Sdx-Tunnel-Disconnect-Cause-Info 51 string ERX
+BEGIN-VENDOR ERX
+
+ATTRIBUTE ERX-Virtual-Router-Name 1 string
+ATTRIBUTE ERX-Address-Pool-Name 2 string
+ATTRIBUTE ERX-Local-Loopback-Interface 3 string
+ATTRIBUTE ERX-Primary-Dns 4 ipaddr
+ATTRIBUTE ERX-Secondary-Dns 5 ipaddr
+ATTRIBUTE ERX-Primary-Wins 6 ipaddr
+ATTRIBUTE ERX-Secondary-Wins 7 ipaddr
+ATTRIBUTE ERX-Tunnel-Virtual-Router 8 string
+ATTRIBUTE ERX-Tunnel-Password 9 string
+ATTRIBUTE ERX-Ingress-Policy-Name 10 string
+ATTRIBUTE ERX-Egress-Policy-Name 11 string
+ATTRIBUTE ERX-Ingress-Statistics 12 string
+ATTRIBUTE ERX-Egress-Statistics 13 string
+ATTRIBUTE ERX-Atm-Service-Category 14 integer
+ATTRIBUTE ERX-Atm-PCR 15 integer
+ATTRIBUTE ERX-Atm-SCR 16 integer
+ATTRIBUTE ERX-Atm-MBS 17 integer
+ATTRIBUTE ERX-Cli-Initial-Access-Level 18 string
+ATTRIBUTE ERX-Cli-Allow-All-VR-Access 19 integer
+ATTRIBUTE ERX-Alternate-Cli-Access-Level 20 string
+ATTRIBUTE ERX-Alternate-Cli-Vrouter-Name 21 string
+ATTRIBUTE ERX-Sa-Validate 22 integer
+ATTRIBUTE ERX-Igmp-Enable 23 integer
+ATTRIBUTE ERX-Pppoe-Description 24 string
+ATTRIBUTE ERX-Redirect-VR-Name 25 string
+ATTRIBUTE ERX-Qos-Profile-Name 26 string
+ATTRIBUTE ERX-Pppoe-Max-Sessions 27 integer
+ATTRIBUTE ERX-Pppoe-Url 28 string
+ATTRIBUTE ERX-Qos-Profile-Interface-Type 29 integer
+ATTRIBUTE ERX-Tunnel-Nas-Port-Method 30 integer
+ATTRIBUTE ERX-Service-Bundle 31 string
+ATTRIBUTE ERX-Tunnel-Tos 32 integer
+ATTRIBUTE ERX-Tunnel-Maximum-Sessions 33 integer
+ATTRIBUTE ERX-Framed-Ip-Route-Tag 34 string
+ATTRIBUTE ERX-Dial-Out-Number 35 string
+ATTRIBUTE ERX-PPP-Username 36 string
+ATTRIBUTE ERX-PPP-Password 37 string
+ATTRIBUTE ERX-PPP-Auth-Protocol 38 integer
+ATTRIBUTE ERX-Minimum-BPS 39 integer
+ATTRIBUTE ERX-Maximum-BPS 40 integer
+ATTRIBUTE ERX-Bearer-Type 41 integer
+ATTRIBUTE ERX-Input-Gigapkts 42 integer
+ATTRIBUTE ERX-Output-Gigapkts 43 integer
+ATTRIBUTE ERX-Tunnel-Interface-Id 44 string
+ATTRIBUTE ERX-IpV6-Virtual-Router 45 string
+ATTRIBUTE ERX-IpV6-Local-Interface 46 string
+ATTRIBUTE ERX-Ipv6-Primary-Dns 47 string
+ATTRIBUTE ERX-Ipv6-Secondary-Dns 48 string
+ATTRIBUTE Sdx-Service-Name 49 string
+ATTRIBUTE Sdx-Session-Volume-Quota 50 string
+ATTRIBUTE Sdx-Tunnel-Disconnect-Cause-Info 51 string
+ATTRIBUTE ERX-Radius-Client-Address 52 ipaddr
+ATTRIBUTE ERX-Service-Description 53 string
+ATTRIBUTE ERX-L2tp-Recv-Window-Size 54 integer
+ATTRIBUTE ERX-Dhcp-Options 55 string
+ATTRIBUTE ERX-Dhcp-Mac-Addr 56 string
+ATTRIBUTE ERX-Dhcp-Gi-Address 57 ipaddr
+ATTRIBUTE ERX-LI-Action 58 integer encrypt=2
+ATTRIBUTE ERX-Med-Dev-Handle 59 octets encrypt=2
+ATTRIBUTE ERX-Med-Ip-Address 60 ipaddr encrypt=2
+ATTRIBUTE ERX-Med-Port-Number 61 integer encrypt=2
+ATTRIBUTE ERX-MLPPP-Bundle-Name 62 string
+ATTRIBUTE ERX-Interface-Desc 63 string
+ATTRIBUTE ERX-Tunnel-Group 64 string
#
# Values Attribute Name Number
#
-VALUE ERX-Ingress-Statistics disable 0
-VALUE ERX-Ingress-Statistics enable 1
+VALUE ERX-Ingress-Statistics disable 0
+VALUE ERX-Ingress-Statistics enable 1
-VALUE ERX-Egress-Statistics disable 0
-VALUE ERX-Egress-Statistics enable 1
+VALUE ERX-Egress-Statistics disable 0
+VALUE ERX-Egress-Statistics enable 1
VALUE ERX-Atm-Service-Category UBR 1
VALUE ERX-Atm-Service-Category UBRPCR 2
VALUE ERX-Tunnel-Nas-Port-Method None 0
VALUE ERX-Tunnel-Nas-Port-Method CISCO-CLID 1
-VALUE ERX-PPP-Auth-Protocol None 0
-VALUE ERX-PPP-Auth-Protocol PAP 1
-VALUE ERX-PPP-Auth-Protocol CHAP 2
-VALUE ERX-PPP-Auth-Protocol PAP-CHAP 3
-VALUE ERX-PPP-Auth-Protocol CHAP-PAP 4
+VALUE ERX-PPP-Auth-Protocol None 0
+VALUE ERX-PPP-Auth-Protocol PAP 1
+VALUE ERX-PPP-Auth-Protocol CHAP 2
+VALUE ERX-PPP-Auth-Protocol PAP-CHAP 3
+VALUE ERX-PPP-Auth-Protocol CHAP-PAP 4
+
+VALUE ERX-Bearer-Type None 0
+VALUE ERX-Bearer-Type Analog 1
+VALUE ERX-Bearer-Type Digital 2
+
+VALUE ERX-LI-Action off 0
+VALUE ERX-LI-Action on 1
+VALUE ERX-LI-Action noop 2
-VALUE ERX-Bearer-Type None 0
-VALUE ERX-Bearer-Type Analog 1
-VALUE ERX-Bearer-Type Digital 2
+END-VENDOR ERX
+# -*- text -*-
#
# Dictionary for Extreme Networks VSA's.
# http://www.extremenetworks.com/
#
# $Id$
#
-VENDOR Extreme 1916
+VENDOR Extreme 1916
-ATTRIBUTE Extreme-Netlogin-Vlan 203 string Extreme
-ATTRIBUTE Extreme-Netlogin-Url 204 string Extreme
-ATTRIBUTE Extreme-Netlogin-Url-Desc 205 string Extreme
-ATTRIBUTE Extreme-Netlogin-Only 206 integer Extreme
+BEGIN-VENDOR Extreme
-VALUE Extreme-Netlogin-Only Disabled 0
-VALUE Extreme-Netlogin-Only Enabled 1
+ATTRIBUTE Extreme-CLI-Authorization 201 integer
+ATTRIBUTE Extreme-Shell-Command 202 string
+ATTRIBUTE Extreme-Netlogin-Vlan 203 string
+ATTRIBUTE Extreme-Netlogin-Url 204 string
+ATTRIBUTE Extreme-Netlogin-Url-Desc 205 string
+ATTRIBUTE Extreme-Netlogin-Only 206 integer
+ATTRIBUTE Extreme-User-Location 208 string
+ATTRIBUTE Extreme-Netlogin-Vlan-Tag 209 integer
+
+VALUE Extreme-CLI-Authorization Disabled 0
+VALUE Extreme-CLI-Authorization Enabled 1
+
+VALUE Extreme-Netlogin-Only Disabled 0
+VALUE Extreme-Netlogin-Only Enabled 1
+
+END-VENDOR Extreme
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Fortinet's VSA's
+# As posted to the list by Richie Lee.
+#
+# $Id$
+#
+##############################################################################
+
+#
+# Fortinet's VSA's
+#
+
+VENDOR Fortinet 12356
+
+BEGIN-VENDOR Fortinet
+ATTRIBUTE Fortinet-Group-Name 1 string
+ATTRIBUTE Fortinet-Client-IP-Address 2 ipaddr
+ATTRIBUTE Fortinet-Vdom-Name 3 string
+
+#
+# Integer Translations
+#
+
+END-VENDOR Fortinet
+# -*- text -*-
#
# dictionary.foundry
#
# Version: $Id$
#
-VENDOR Foundry 1991
+VENDOR Foundry 1991
-ATTRIBUTE Foundry-Privilege-Level 1 integer Foundry
-ATTRIBUTE Foundry-Command-String 2 string Foundry
-ATTRIBUTE Foundry-Command-Exception-Flag 3 integer Foundry
-ATTRIBUTE Foundry-INM-Privilege 4 integer Foundry
-VALUE Foundry-INM-Privilege AAA_pri_0 0
-VALUE Foundry-INM-Privilege AAA_pri_1 1
-VALUE Foundry-INM-Privilege AAA_pri_2 2
-VALUE Foundry-INM-Privilege AAA_pri_3 3
-VALUE Foundry-INM-Privilege AAA_pri_4 4
-VALUE Foundry-INM-Privilege AAA_pri_5 5
-VALUE Foundry-INM-Privilege AAA_pri_6 6
-VALUE Foundry-INM-Privilege AAA_pri_7 7
-VALUE Foundry-INM-Privilege AAA_pri_8 8
-VALUE Foundry-INM-Privilege AAA_pri_9 9
-VALUE Foundry-INM-Privilege AAA_pri_10 10
-VALUE Foundry-INM-Privilege AAA_pri_11 11
-VALUE Foundry-INM-Privilege AAA_pri_12 12
-VALUE Foundry-INM-Privilege AAA_pri_13 13
-VALUE Foundry-INM-Privilege AAA_pri_14 14
-VALUE Foundry-INM-Privilege AAA_pri_15 15
+BEGIN-VENDOR Foundry
+
+ATTRIBUTE Foundry-Privilege-Level 1 integer
+ATTRIBUTE Foundry-Command-String 2 string
+ATTRIBUTE Foundry-Command-Exception-Flag 3 integer
+ATTRIBUTE Foundry-INM-Privilege 4 integer
+
+VALUE Foundry-INM-Privilege AAA_pri_0 0
+VALUE Foundry-INM-Privilege AAA_pri_1 1
+VALUE Foundry-INM-Privilege AAA_pri_2 2
+VALUE Foundry-INM-Privilege AAA_pri_3 3
+VALUE Foundry-INM-Privilege AAA_pri_4 4
+VALUE Foundry-INM-Privilege AAA_pri_5 5
+VALUE Foundry-INM-Privilege AAA_pri_6 6
+VALUE Foundry-INM-Privilege AAA_pri_7 7
+VALUE Foundry-INM-Privilege AAA_pri_8 8
+VALUE Foundry-INM-Privilege AAA_pri_9 9
+VALUE Foundry-INM-Privilege AAA_pri_10 10
+VALUE Foundry-INM-Privilege AAA_pri_11 11
+VALUE Foundry-INM-Privilege AAA_pri_12 12
+VALUE Foundry-INM-Privilege AAA_pri_13 13
+VALUE Foundry-INM-Privilege AAA_pri_14 14
+VALUE Foundry-INM-Privilege AAA_pri_15 15
+
+END-VENDOR Foundry
+# -*- text -*-
#
# The FreeRADIUS Vendor-Specific dictionary.
#
# http://www.isi.edu/in-notes/iana/assignments/enterprise-numbers
#
-VENDOR FreeRADIUS 11344
+VENDOR FreeRADIUS 11344
-BEGIN-VENDOR FreeRADIUS
+BEGIN-VENDOR FreeRADIUS
-ATTRIBUTE FreeRADIUS-Proxied-To 1 ipaddr
+ATTRIBUTE FreeRADIUS-Proxied-To 1 ipaddr
END-VENDOR FreeRADIUS
--- /dev/null
+# -*- text -*-
+#
+# Non Protocol Attributes used by FreeRADIUS
+#
+# $Id$
+#
+
+# The attributes number ranges are allocates as follows:
+#
+# Range: 500-999
+# server-side attributes which can go in a reply list
+
+# These attributes CAN go in the reply item list.
+ATTRIBUTE Fall-Through 500 integer
+ATTRIBUTE Exec-Program 502 string
+ATTRIBUTE Exec-Program-Wait 503 string
+
+# These attributes CANNOT go in the reply item list.
+
+#
+# Range: 1000+
+# Attributes which cannot go in a reply list.
+#
+#
+# Range: 1000-1199
+# Miscellaneous server attributes.
+#
+#
+# Non-Protocol Attributes
+# These attributes are used internally by the server
+#
+ATTRIBUTE Auth-Type 1000 integer
+ATTRIBUTE Menu 1001 string
+ATTRIBUTE Termination-Menu 1002 string
+ATTRIBUTE Prefix 1003 string
+ATTRIBUTE Suffix 1004 string
+ATTRIBUTE Group 1005 string
+ATTRIBUTE Crypt-Password 1006 string
+ATTRIBUTE Connect-Rate 1007 integer
+ATTRIBUTE Add-Prefix 1008 string
+ATTRIBUTE Add-Suffix 1009 string
+ATTRIBUTE Expiration 1010 date
+ATTRIBUTE Autz-Type 1011 integer
+ATTRIBUTE Acct-Type 1012 integer
+ATTRIBUTE Session-Type 1013 integer
+ATTRIBUTE Post-Auth-Type 1014 integer
+ATTRIBUTE Pre-Proxy-Type 1015 integer
+ATTRIBUTE Post-Proxy-Type 1016 integer
+ATTRIBUTE Pre-Acct-Type 1017 integer
+
+#
+# This is the EAP type of authentication, which is set
+# by the EAP module, for informational purposes only.
+#
+ATTRIBUTE EAP-Type 1018 integer
+ATTRIBUTE EAP-TLS-Require-Client-Cert 1019 integer
+ATTRIBUTE EAP-Id 1020 integer
+ATTRIBUTE EAP-Code 1021 integer
+ATTRIBUTE EAP-MD5-Password 1022 string
+ATTRIBUTE PEAP-Version 1023 integer
+
+#
+# Range: 1023-1028
+# unused
+#
+ATTRIBUTE User-Category 1029 string
+ATTRIBUTE Group-Name 1030 string
+ATTRIBUTE Huntgroup-Name 1031 string
+ATTRIBUTE Simultaneous-Use 1034 integer
+ATTRIBUTE Strip-User-Name 1035 integer
+ATTRIBUTE Hint 1040 string
+ATTRIBUTE Pam-Auth 1041 string
+ATTRIBUTE Login-Time 1042 string
+ATTRIBUTE Stripped-User-Name 1043 string
+ATTRIBUTE Current-Time 1044 string
+ATTRIBUTE Realm 1045 string
+ATTRIBUTE No-Such-Attribute 1046 string
+ATTRIBUTE Packet-Type 1047 integer
+ATTRIBUTE Proxy-To-Realm 1048 string
+ATTRIBUTE Replicate-To-Realm 1049 string
+ATTRIBUTE Acct-Session-Start-Time 1050 date
+ATTRIBUTE Acct-Unique-Session-Id 1051 string
+ATTRIBUTE Client-IP-Address 1052 ipaddr
+ATTRIBUTE Ldap-UserDn 1053 string
+ATTRIBUTE NS-MTA-MD5-Password 1054 string
+ATTRIBUTE SQL-User-Name 1055 string
+ATTRIBUTE LM-Password 1057 octets
+ATTRIBUTE NT-Password 1058 octets
+ATTRIBUTE SMB-Account-CTRL 1059 integer
+ATTRIBUTE SMB-Account-CTRL-TEXT 1061 string
+ATTRIBUTE User-Profile 1062 string
+ATTRIBUTE Digest-Realm 1063 string
+ATTRIBUTE Digest-Nonce 1064 string
+ATTRIBUTE Digest-Method 1065 string
+ATTRIBUTE Digest-URI 1066 string
+ATTRIBUTE Digest-QOP 1067 string
+ATTRIBUTE Digest-Algorithm 1068 string
+ATTRIBUTE Digest-Body-Digest 1069 string
+ATTRIBUTE Digest-CNonce 1070 string
+ATTRIBUTE Digest-Nonce-Count 1071 string
+ATTRIBUTE Digest-User-Name 1072 string
+ATTRIBUTE Pool-Name 1073 string
+ATTRIBUTE Ldap-Group 1074 string
+ATTRIBUTE Module-Success-Message 1075 string
+ATTRIBUTE Module-Failure-Message 1076 string
+# X99-Fast 1077 integer
+ATTRIBUTE Rewrite-Rule 1078 string
+ATTRIBUTE Sql-Group 1079 string
+ATTRIBUTE Response-Packet-Type 1080 integer
+# 1081 unused
+ATTRIBUTE MS-CHAP-Use-NTLM-Auth 1082 integer
+ATTRIBUTE NTLM-User-Name 1083 string
+ATTRIBUTE Packet-Src-IP-Address 1084 ipaddr
+ATTRIBUTE Packet-Dst-IP-Address 1085 ipaddr
+ATTRIBUTE Packet-Src-Port 1086 integer
+ATTRIBUTE Packet-Dst-Port 1087 integer
+ATTRIBUTE Packet-Authentication-Vector 1088 octets
+ATTRIBUTE Time-Of-Day 1089 string
+ATTRIBUTE Request-Processing-Stage 1090 string
+ATTRIBUTE Cache-No-Caching 1091 string
+ATTRIBUTE Cache-Delete-Cache 1092 string
+ATTRIBUTE SHA-Password 1093 octets
+ATTRIBUTE SSHA-Password 1094 octets
+ATTRIBUTE MD5-Password 1095 octets
+ATTRIBUTE SMD5-Password 1096 octets
+ATTRIBUTE Packet-Src-IPv6-Address 1097 ipv6addr
+ATTRIBUTE Packet-Dst-IPv6-Address 1098 ipv6addr
+ATTRIBUTE Server-Identity 1099 string
+
+#
+# Range: 1200-1279
+# EAP-SIM (and other EAP type) weirdness.
+#
+# For EAP-SIM, some attribute definitions for database interface
+#
+ATTRIBUTE EAP-Sim-Subtype 1200 integer
+
+ATTRIBUTE EAP-Sim-Rand1 1201 octets
+ATTRIBUTE EAP-Sim-Rand2 1202 octets
+ATTRIBUTE EAP-Sim-Rand3 1203 octets
+
+ATTRIBUTE EAP-Sim-SRES1 1204 octets
+ATTRIBUTE EAP-Sim-SRES2 1205 octets
+ATTRIBUTE EAP-Sim-SRES3 1206 octets
+
+VALUE EAP-Sim-Subtype Start 10
+VALUE EAP-Sim-Subtype Challenge 11
+VALUE EAP-Sim-Subtype Notification 12
+VALUE EAP-Sim-Subtype Re-authentication 13
+
+# this attribute is used internally by the client code.
+ATTRIBUTE EAP-Sim-State 1207 integer
+
+ATTRIBUTE EAP-Sim-IMSI 1208 string
+ATTRIBUTE EAP-Sim-HMAC 1209 string
+ATTRIBUTE EAP-Sim-KEY 1210 octets
+ATTRIBUTE EAP-Sim-EXTRA 1211 octets
+
+ATTRIBUTE EAP-Sim-KC1 1212 octets
+ATTRIBUTE EAP-Sim-KC2 1213 octets
+ATTRIBUTE EAP-Sim-KC3 1214 octets
+
+#
+# Range: 1280 - 1535
+# EAP-type specific attributes
+#
+
+# these are PW_EAP_X + 1280
+ATTRIBUTE EAP-Type-Identity 1281 string
+ATTRIBUTE EAP-Type-Notification 1282 string
+ATTRIBUTE EAP-Type-NAK 1283 string
+ATTRIBUTE EAP-Type-MD5 1284 octets
+ATTRIBUTE EAP-Type-OTP 1285 string
+ATTRIBUTE EAP-Type-GTC 1286 string
+ATTRIBUTE EAP-Type-TLS 1297 octets
+ATTRIBUTE EAP-Type-SIM 1298 octets
+ATTRIBUTE EAP-Type-LEAP 1301 octets
+ATTRIBUTE EAP-Type-SIM2 1302 octets
+ATTRIBUTE EAP-Type-TTLS 1305 octets
+ATTRIBUTE EAP-Type-PEAP 1309 octets
+
+#
+# Range: 1536 - 1791
+# EAP Sim sub-types.
+#
+
+# these are PW_EAP_SIM_X + 1536
+ATTRIBUTE EAP-Sim-RAND 1537 octets
+ATTRIBUTE EAP-Sim-PADDING 1542 octets
+ATTRIBUTE EAP-Sim-NONCE_MT 1543 octets
+ATTRIBUTE EAP-Sim-PERMANENT_ID_REQ 1546 octets
+ATTRIBUTE EAP-Sim-MAC 1547 octets
+ATTRIBUTE EAP-Sim-NOTIFICATION 1548 octets
+ATTRIBUTE EAP-Sim-ANY_ID_REQ 1549 octets
+ATTRIBUTE EAP-Sim-IDENTITY 1550 octets
+ATTRIBUTE EAP-Sim-VERSION_LIST 1551 octets
+ATTRIBUTE EAP-Sim-SELECTED_VERSION 1552 octets
+ATTRIBUTE EAP-Sim-FULLAUTH_ID_REQ 1553 octets
+ATTRIBUTE EAP-Sim-COUNTER 1555 octets
+ATTRIBUTE EAP-Sim-COUNTER_TOO_SMALL 1556 octets
+ATTRIBUTE EAP-Sim-NONCE_S 1557 octets
+ATTRIBUTE EAP-Sim-IV 1665 octets
+ATTRIBUTE EAP-Sim-ENCR_DATA 1666 octets
+ATTRIBUTE EAP-Sim-NEXT_PSEUDONUM 1668 octets
+ATTRIBUTE EAP-Sim-NEXT_REAUTH_ID 1669 octets
+ATTRIBUTE EAP-Sim-CHECKCODE 1670 octets
+
+#
+# Range: 1800-1899
+# Temporary attributes, for local storage.
+#
+ATTRIBUTE Tmp-String-0 1800 string
+ATTRIBUTE Tmp-String-1 1801 string
+ATTRIBUTE Tmp-String-2 1802 string
+ATTRIBUTE Tmp-String-3 1803 string
+ATTRIBUTE Tmp-String-4 1804 string
+ATTRIBUTE Tmp-String-5 1805 string
+ATTRIBUTE Tmp-String-6 1806 string
+ATTRIBUTE Tmp-String-7 1807 string
+ATTRIBUTE Tmp-String-8 1808 string
+ATTRIBUTE Tmp-String-9 1809 string
+
+ATTRIBUTE Tmp-Integer-0 1810 integer
+ATTRIBUTE Tmp-Integer-1 1811 integer
+ATTRIBUTE Tmp-Integer-2 1812 integer
+ATTRIBUTE Tmp-Integer-3 1813 integer
+ATTRIBUTE Tmp-Integer-4 1814 integer
+ATTRIBUTE Tmp-Integer-5 1815 integer
+ATTRIBUTE Tmp-Integer-6 1816 integer
+ATTRIBUTE Tmp-Integer-7 1817 integer
+ATTRIBUTE Tmp-Integer-8 1818 integer
+ATTRIBUTE Tmp-Integer-9 1819 integer
+
+ATTRIBUTE Tmp-IP-Address-0 1820 ipaddr
+ATTRIBUTE Tmp-IP-Address-1 1821 ipaddr
+ATTRIBUTE Tmp-IP-Address-2 1822 ipaddr
+ATTRIBUTE Tmp-IP-Address-3 1823 ipaddr
+ATTRIBUTE Tmp-IP-Address-4 1824 ipaddr
+ATTRIBUTE Tmp-IP-Address-5 1825 ipaddr
+ATTRIBUTE Tmp-IP-Address-6 1826 ipaddr
+ATTRIBUTE Tmp-IP-Address-7 1827 ipaddr
+ATTRIBUTE Tmp-IP-Address-8 1828 ipaddr
+ATTRIBUTE Tmp-IP-Address-9 1829 ipaddr
+
+#
+# Range: 1900-2999
+# Free
+#
+# Range: 3000-3999
+# Site-local attributes (see raddb/dictionary.in)
+# Do NOT define attributes in this range!
+#
+# Range: 4000-65535
+# Unused
+#
+# Range: 65536-
+# Invalid. Don't use.
+#
+
+#
+# Non-Protocol Integer Translations
+#
+
+VALUE Auth-Type Local 0
+VALUE Auth-Type System 1
+VALUE Auth-Type SecurID 2
+VALUE Auth-Type Crypt-Local 3
+VALUE Auth-Type Reject 4
+VALUE Auth-Type ActivCard 5
+VALUE Auth-Type EAP 6
+VALUE Auth-Type ARAP 7
+
+#
+# FreeRADIUS extensions (most originally from Cistron)
+#
+VALUE Auth-Type Accept 254
+
+VALUE Auth-Type PAP 1024
+VALUE Auth-Type CHAP 1025
+VALUE Auth-Type LDAP 1026
+VALUE Auth-Type PAM 1027
+VALUE Auth-Type MS-CHAP 1028
+VALUE Auth-Type Kerberos 1029
+VALUE Auth-Type CRAM 1030
+VALUE Auth-Type NS-MTA-MD5 1031
+# 1032 is unused (was a duplicate of CRAM)
+VALUE Auth-Type SMB 1033
+
+#
+# Authorization type, too.
+#
+VALUE Autz-Type Local 0
+
+#
+# And accounting
+#
+VALUE Acct-Type Local 0
+
+#
+# And Session handling
+#
+VALUE Session-Type Local 0
+
+#
+# And Post-Auth
+VALUE Post-Auth-Type Local 0
+
+#
+# Experimental Non-Protocol Integer Translations for FreeRADIUS
+#
+VALUE Fall-Through No 0
+VALUE Fall-Through Yes 1
+
+#VALUE Strip-User-Name No 0
+#VALUE Strip-User-Name Yes 1
+
+VALUE Packet-Type Access-Request 1
+VALUE Packet-Type Access-Accept 2
+VALUE Packet-Type Access-Reject 3
+VALUE Packet-Type Accounting-Request 4
+VALUE Packet-Type Accounting-Response 5
+VALUE Packet-Type Accounting-Status 6
+VALUE Packet-Type Password-Request 7
+VALUE Packet-Type Password-Accept 8
+VALUE Packet-Type Password-Reject 9
+VALUE Packet-Type Accounting-Message 10
+VALUE Packet-Type Access-Challenge 11
+VALUE Packet-Type Status-Server 12
+VALUE Packet-Type Status-Client 13
+
+#
+# The following packet types are described in RFC 2882,
+# but they are NOT part of the RADIUS standard. Instead,
+# they are informational about vendor-specific extensions
+# to the RADIUS standard.
+#
+VALUE Packet-Type Resource-Free-Request 21
+VALUE Packet-Type Resource-Free-Response 22
+VALUE Packet-Type Resource-Query-Request 23
+VALUE Packet-Type Resource-Query-Response 24
+VALUE Packet-Type Alternate-Resource-Reclaim-Request 25
+VALUE Packet-Type NAS-Reboot-Request 26
+VALUE Packet-Type NAS-Reboot-Response 27
+VALUE Packet-Type Next-Passcode 29
+VALUE Packet-Type New-Pin 30
+VALUE Packet-Type Terminate-Session 31
+VALUE Packet-Type Password-Expired 32
+VALUE Packet-Type Event-Request 33
+VALUE Packet-Type Event-Response 34
+VALUE Packet-Type Disconnect-Request 40
+VALUE Packet-Type Disconnect-ACK 41
+VALUE Packet-Type Disconnect-NAK 42
+VALUE Packet-Type CoF-Request 43
+VALUE Packet-Type CoF-ACK 44
+VALUE Packet-Type CoF-NAK 45
+VALUE Packet-Type IP-Address-Allocate 50
+VALUE Packet-Type IP-Address-Release 51
+
+VALUE Response-Packet-Type Access-Request 1
+VALUE Response-Packet-Type Access-Accept 2
+VALUE Response-Packet-Type Access-Reject 3
+VALUE Response-Packet-Type Accounting-Request 4
+VALUE Response-Packet-Type Accounting-Response 5
+VALUE Response-Packet-Type Accounting-Status 6
+VALUE Response-Packet-Type Password-Request 7
+VALUE Response-Packet-Type Password-Accept 8
+VALUE Response-Packet-Type Password-Reject 9
+VALUE Response-Packet-Type Accounting-Message 10
+VALUE Response-Packet-Type Access-Challenge 11
+VALUE Response-Packet-Type Status-Server 12
+VALUE Response-Packet-Type Status-Client 13
+
+#
+# EAP Sub-types, inside of Request and Response packets
+#
+# http://www.iana.org/assignments/ppp-numbers
+# "PPP EAP REQUEST/RESPONSE TYPES"
+#
+#
+# See dictionary.microsoft, MS-Acct-EAP-Type for similar definitions
+#
+VALUE EAP-Type None 0
+VALUE EAP-Type Identity 1
+VALUE EAP-Type Notification 2
+VALUE EAP-Type NAK 3
+VALUE EAP-Type MD5-Challenge 4
+VALUE EAP-Type One-Time-Password 5
+VALUE EAP-Type Generic-Token-Card 6
+VALUE EAP-Type RSA-Public-Key 9
+VALUE EAP-Type DSS-Unilateral 10
+VALUE EAP-Type KEA 11
+VALUE EAP-Type KEA-Validate 12
+VALUE EAP-Type EAP-TLS 13
+VALUE EAP-Type Defender-Token 14
+VALUE EAP-Type RSA-SecurID-EAP 15
+VALUE EAP-Type Arcot-Systems-EAP 16
+VALUE EAP-Type Cisco-LEAP 17
+VALUE EAP-Type Nokia-IP-Smart-Card 18
+VALUE EAP-Type SIM 18
+VALUE EAP-Type SRP-SHA1-Part-1 19
+VALUE EAP-Type SRP-SHA1-Part-2 20
+VALUE EAP-Type EAP-TTLS 21
+VALUE EAP-Type Remote-Access-Service 22
+VALUE EAP-Type UMTS 23
+VALUE EAP-Type EAP-3Com-Wireless 24
+VALUE EAP-Type PEAP 25
+VALUE EAP-Type MS-EAP-Authentication 26
+VALUE EAP-Type MAKE 27
+VALUE EAP-Type CRYPTOCard 28
+VALUE EAP-Type EAP-MSCHAP-V2 29
+VALUE EAP-Type DynamID 30
+VALUE EAP-Type Rob-EAP 31
+VALUE EAP-Type SecurID-EAP 32
+VALUE EAP-Type MS-Authentication-TLV 33
+VALUE EAP-Type SentriNET 34
+VALUE EAP-Type EAP-Actiontec-Wireless 35
+VALUE EAP-Type Cogent-Biomentric-EAP 36
+VALUE EAP-Type AirFortress-EAP 37
+VALUE EAP-Type EAP-HTTP-Digest 38
+VALUE EAP-Type SecuriSuite-EAP 39
+VALUE EAP-Type DeviceConnect-EAP 40
+VALUE EAP-Type EAP-SPEKE 41
+VALUE EAP-Type EAP-MOBAC 42
+
+#
+# These are duplicate values, to get around the problem of
+# having two MS-CHAPv2 EAP types.
+#
+VALUE EAP-Type Microsoft-MS-CHAPv2 26
+VALUE EAP-Type Cisco-MS-CHAPv2 29
+
+#
+# And this is what most people mean by MS-CHAPv2
+#
+VALUE EAP-Type MS-CHAP-V2 26
+
+#
+# This says TLS, but it's only valid for TTLS & PEAP.
+# EAP-TLS *always* requires a client certificate.
+#
+VALUE EAP-TLS-Require-Client-Cert No 0
+VALUE EAP-TLS-Require-Client-Cert Yes 1
+
+#
+# These are the EAP-Code values.
+#
+VALUE EAP-Code Request 1
+VALUE EAP-Code Response 2
+VALUE EAP-Code Success 3
+VALUE EAP-Code Failure 4
+
+#
+# For MS-CHAP, do we run ntlm_auth, or not.
+#
+VALUE MS-CHAP-Use-NTLM-Auth No 0
+VALUE MS-CHAP-Use-NTLM-Auth Yes 1
+# -*- text -*-
# Gandalf dictionary
#
# Version: 1.00 24-July-2003 Blaise St-Laurent <bstlaurent@okiok.com>
#
# $Id$
#
-VENDOR Gandalf 64
+VENDOR Gandalf 64
#
# Vendor-specific attributes
#
-ATTRIBUTE Gandalf-Remote-LAN-Name 0 string Gandalf
-ATTRIBUTE Gandalf-Operational-Modes 1 integer Gandalf
-ATTRIBUTE Gandalf-Compression-Status 2 integer Gandalf
-ATTRIBUTE Gandalf-Min-Outgoing-Bearer 3 integer Gandalf
-ATTRIBUTE Gandalf-Authentication-String 5 string Gandalf
-ATTRIBUTE Gandalf-PPP-Authentication 6 integer Gandalf
-ATTRIBUTE Gandalf-PPP-NCP-Type 7 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Multicast-In 8 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Broadcast-In 9 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Unicast-In 10 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Multicast-Out 11 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Broadcast-Out 12 integer Gandalf
-ATTRIBUTE Gandalf-Fwd-Unicast-Out 13 integer Gandalf
-ATTRIBUTE Gandalf-Around-The-Corner 14 integer Gandalf
-ATTRIBUTE Gandalf-Channel-Group-Name-1 15 string Gandalf
-ATTRIBUTE Gandalf-Dial-Prefix-Name-1 16 string Gandalf
-ATTRIBUTE Gandalf-Phone-Number-1 17 string Gandalf
-ATTRIBUTE Gandalf-Calling-Line-ID-1 18 string Gandalf
-ATTRIBUTE Gandalf-Channel-Group-Name-2 19 string Gandalf
-ATTRIBUTE Gandalf-Dial-Prefix-Name-2 20 string Gandalf
-ATTRIBUTE Gandalf-Phone-Number-2 21 string Gandalf
-ATTRIBUTE Gandalf-Calling-Line-ID-2 22 string Gandalf
-ATTRIBUTE Gandalf-IPX-Spoofing-State 23 integer Gandalf
-ATTRIBUTE Gandalf-IPX-Watchdog-Spoof 24 integer Gandalf
-ATTRIBUTE Gandalf-SAP-Group-Name-1 25 string Gandalf
-ATTRIBUTE Gandalf-SAP-Group-Name-2 26 string Gandalf
-ATTRIBUTE Gandalf-SAP-Group-Name-3 27 string Gandalf
-ATTRIBUTE Gandalf-SAP-Group-Name-4 28 string Gandalf
-ATTRIBUTE Gandalf-SAP-Group-Name-5 29 string Gandalf
-ATTRIBUTE Gandalf-Hunt-Group 30 string Gandalf
-ATTRIBUTE Gandalf-Modem-Mode 31 integer Gandalf
-ATTRIBUTE Gandalf-Modem-Required-1 32 integer Gandalf
-ATTRIBUTE Gandalf-Modem-Required-2 33 integer Gandalf
-
-VALUE Gandalf-Operational-Modes Disabled 1
-VALUE Gandalf-Operational-Modes Called-Only 2
-VALUE Gandalf-Operational-Modes Calling-Called 3
-VALUE Gandalf-Operational-Modes Calling-Only 4
-
-VALUE Gandalf-Compression-Status Disabled 1
-VALUE Gandalf-Compression-Status Enabled 2
+BEGIN-VENDOR Gandalf
+
+ATTRIBUTE Gandalf-Remote-LAN-Name 0 string
+ATTRIBUTE Gandalf-Operational-Modes 1 integer
+ATTRIBUTE Gandalf-Compression-Status 2 integer
+ATTRIBUTE Gandalf-Min-Outgoing-Bearer 3 integer
+ATTRIBUTE Gandalf-Authentication-String 5 string
+ATTRIBUTE Gandalf-PPP-Authentication 6 integer
+ATTRIBUTE Gandalf-PPP-NCP-Type 7 integer
+ATTRIBUTE Gandalf-Fwd-Multicast-In 8 integer
+ATTRIBUTE Gandalf-Fwd-Broadcast-In 9 integer
+ATTRIBUTE Gandalf-Fwd-Unicast-In 10 integer
+ATTRIBUTE Gandalf-Fwd-Multicast-Out 11 integer
+ATTRIBUTE Gandalf-Fwd-Broadcast-Out 12 integer
+ATTRIBUTE Gandalf-Fwd-Unicast-Out 13 integer
+ATTRIBUTE Gandalf-Around-The-Corner 14 integer
+ATTRIBUTE Gandalf-Channel-Group-Name-1 15 string
+ATTRIBUTE Gandalf-Dial-Prefix-Name-1 16 string
+ATTRIBUTE Gandalf-Phone-Number-1 17 string
+ATTRIBUTE Gandalf-Calling-Line-ID-1 18 string
+ATTRIBUTE Gandalf-Channel-Group-Name-2 19 string
+ATTRIBUTE Gandalf-Dial-Prefix-Name-2 20 string
+ATTRIBUTE Gandalf-Phone-Number-2 21 string
+ATTRIBUTE Gandalf-Calling-Line-ID-2 22 string
+ATTRIBUTE Gandalf-IPX-Spoofing-State 23 integer
+ATTRIBUTE Gandalf-IPX-Watchdog-Spoof 24 integer
+ATTRIBUTE Gandalf-SAP-Group-Name-1 25 string
+ATTRIBUTE Gandalf-SAP-Group-Name-2 26 string
+ATTRIBUTE Gandalf-SAP-Group-Name-3 27 string
+ATTRIBUTE Gandalf-SAP-Group-Name-4 28 string
+ATTRIBUTE Gandalf-SAP-Group-Name-5 29 string
+ATTRIBUTE Gandalf-Hunt-Group 30 string
+ATTRIBUTE Gandalf-Modem-Mode 31 integer
+ATTRIBUTE Gandalf-Modem-Required-1 32 integer
+ATTRIBUTE Gandalf-Modem-Required-2 33 integer
+
+VALUE Gandalf-Operational-Modes Disabled 1
+VALUE Gandalf-Operational-Modes Called-Only 2
+VALUE Gandalf-Operational-Modes Calling-Called 3
+VALUE Gandalf-Operational-Modes Calling-Only 4
+
+VALUE Gandalf-Compression-Status Disabled 1
+VALUE Gandalf-Compression-Status Enabled 2
VALUE Gandalf-Min-Outgoing-Bearer Unrestricted-64K 1
VALUE Gandalf-Min-Outgoing-Bearer Digital-56K 2
VALUE Gandalf-Min-Outgoing-Bearer 3100Hz-Audio 3
-VALUE Gandalf-PPP-Authentication CHAP 1
-VALUE Gandalf-PPP-Authentication PAP 2
-VALUE Gandalf-PPP-Authentication PAP-Sending-on-Incoming-Calls 3
+VALUE Gandalf-PPP-Authentication CHAP 1
+VALUE Gandalf-PPP-Authentication PAP 2
+VALUE Gandalf-PPP-Authentication PAP-Sending-on-Incoming-Calls 3
-VALUE Gandalf-PPP-NCP-Type BCP 2
-VALUE Gandalf-PPP-NCP-Type IPCP 3
+VALUE Gandalf-PPP-NCP-Type BCP 2
+VALUE Gandalf-PPP-NCP-Type IPCP 3
-VALUE Gandalf-Fwd-Multicast-In Disabled 1
-VALUE Gandalf-Fwd-Multicast-In Enabled 2
+VALUE Gandalf-Fwd-Multicast-In Disabled 1
+VALUE Gandalf-Fwd-Multicast-In Enabled 2
-VALUE Gandalf-Fwd-Broadcast-In Disabled 1
-VALUE Gandalf-Fwd-Broadcast-In Enabled 2
+VALUE Gandalf-Fwd-Broadcast-In Disabled 1
+VALUE Gandalf-Fwd-Broadcast-In Enabled 2
-VALUE Gandalf-Fwd-Unicast-In Disabled 1
-VALUE Gandalf-Fwd-Unicast-In Enabled 2
+VALUE Gandalf-Fwd-Unicast-In Disabled 1
+VALUE Gandalf-Fwd-Unicast-In Enabled 2
-VALUE Gandalf-Fwd-Multicast-Out Disabled 1
-VALUE Gandalf-Fwd-Multicast-Out Enabled 2
+VALUE Gandalf-Fwd-Multicast-Out Disabled 1
+VALUE Gandalf-Fwd-Multicast-Out Enabled 2
-VALUE Gandalf-Fwd-Broadcast-Out Disabled 1
-VALUE Gandalf-Fwd-Broadcast-Out Enabled 2
+VALUE Gandalf-Fwd-Broadcast-Out Disabled 1
+VALUE Gandalf-Fwd-Broadcast-Out Enabled 2
-VALUE Gandalf-Fwd-Unicast-Out Disabled 1
-VALUE Gandalf-Fwd-Unicast-Out Enabled 2
+VALUE Gandalf-Fwd-Unicast-Out Disabled 1
+VALUE Gandalf-Fwd-Unicast-Out Enabled 2
-VALUE Gandalf-IPX-Spoofing-State Forward 1
-VALUE Gandalf-IPX-Spoofing-State Spoof 2
-VALUE Gandalf-IPX-Spoofing-State Filter-all-outgoing-RIP-SAP 3
+VALUE Gandalf-IPX-Spoofing-State Forward 1
+VALUE Gandalf-IPX-Spoofing-State Spoof 2
+VALUE Gandalf-IPX-Spoofing-State Filter-all-outgoing-RIP-SAP 3
-VALUE Gandalf-IPX-Watchdog-Spoof Disabled 1
-VALUE Gandalf-IPX-Watchdog-Spoof Enabled 2
+VALUE Gandalf-IPX-Watchdog-Spoof Disabled 1
+VALUE Gandalf-IPX-Watchdog-Spoof Enabled 2
-VALUE Gandalf-Modem-Mode Disabled 1
-VALUE Gandalf-Modem-Mode Enabled 2
+VALUE Gandalf-Modem-Mode Disabled 1
+VALUE Gandalf-Modem-Mode Enabled 2
-VALUE Gandalf-Modem-Required-1 Disabled 1
-VALUE Gandalf-Modem-Required-1 Enabled 2
+VALUE Gandalf-Modem-Required-1 Disabled 1
+VALUE Gandalf-Modem-Required-1 Enabled 2
-VALUE Gandalf-Modem-Required-2 Disabled 1
-VALUE Gandalf-Modem-Required-2 Enabled 2
+VALUE Gandalf-Modem-Required-2 Disabled 1
+VALUE Gandalf-Modem-Required-2 Enabled 2
+
+END-VENDOR Gandalf
+# -*- text -*-
#
# dictionary.garderos
#
#
# http://www.garderos.com
-VENDOR Garderos 16108
+VENDOR Garderos 16108
#
# Standard attribute
#
-ATTRIBUTE Garderos-Location-Name 1 string Garderos
-ATTRIBUTE Garderos-Service-Name 2 string Garderos
+BEGIN-VENDOR Garderos
+
+ATTRIBUTE Garderos-Location-Name 1 string
+ATTRIBUTE Garderos-Service-Name 2 string
+
+END-VENDOR Garderos
--- /dev/null
+# -*- text -*-
+#
+# Gemtek Systems VSA's
+# Version: dictionary.gemtek, v1.2 2004/07/13
+
+VENDOR Gemtek 10529
+
+BEGIN-VENDOR Gemtek
+
+# Attributes for volume accounting limit.
+
+ATTRIBUTE Acct-Session-Input-Octets 21 integer
+ATTRIBUTE Acct-Session-Input-Gigawords 22 integer
+ATTRIBUTE Acct-Session-Output-Octets 23 integer
+ATTRIBUTE Acct-Session-Output-Gigawords 24 integer
+ATTRIBUTE Acct-Session-Octets 25 integer
+ATTRIBUTE Acct-Session-Gigawords 26 integer
+
+END-VENDOR Gemtek
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# ipUnplugged
+# http://www.ipunplugged.com/
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR ipUnplugged 5925
+
+BEGIN-VENDOR ipUnplugged
+
+ATTRIBUTE IPU-MIP-Spi 51 integer
+ATTRIBUTE IPU-MIP-Key 52 string
+ATTRIBUTE IPU-MIP-Alg-Type 53 integer
+ATTRIBUTE IPU-MIP-Alg-Mode 54 integer
+ATTRIBUTE IPU-MIP-Replay-Prot 55 integer
+ATTRIBUTE IPU-IKE-Remote-Addr 61 ipaddr
+ATTRIBUTE IPU-IKE-Local-Addr 62 ipaddr
+ATTRIBUTE IPU-IKE-Auth 63 string
+ATTRIBUTE IPU-IKE-Conf-Name 64 string
+ATTRIBUTE IPU-IKE-Cmd 65 string
+
+END-VENDOR ipUnplugged
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# UTStarcom Issanni DSL router.
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Issanni 5948
+
+BEGIN-VENDOR Issanni
+#
+# UTStarcom Issanni DSL router.
+#
+ATTRIBUTE Issanni-SoftFlow-Template 1 string
+ATTRIBUTE Issanni-NAT-Support 2 string
+ATTRIBUTE Issanni-Routing-Context 3 string
+ATTRIBUTE Issanni-Tunnel-Name 4 string
+ATTRIBUTE Issanni-IP-Pool-Name 5 string
+ATTRIBUTE Issanni-PPPoE-URL 6 string
+ATTRIBUTE Issanni-PPPoE-MOTM 7 string
+ATTRIBUTE Issanni-Service 8 string
+ATTRIBUTE Issanni-Pri-DNS 9 ipaddr
+ATTRIBUTE Issanni-Sec-DNS 10 ipaddr
+ATTRIBUTE Issanni-Pri-NBNS 11 ipaddr
+ATTRIBUTE Issanni-Sec-NBNS 12 ipaddr
+ATTRIBUTE Issanni-Traffic-Class 13 string
+ATTRIBUTE Issanni-Tunnel-Type 14 integer
+ATTRIBUTE Issanni-NAT-Type 15 integer
+ATTRIBUTE Issanni-QOS-Class 16 string
+ATTRIBUTE Issanni-Interface-Name 17 string
+
+VALUE Issanni-Tunnel-Type IP-IP 1
+VALUE Issanni-Tunnel-Type ESP 2
+VALUE Issanni-Tunnel-Type L2TP 3
+
+VALUE Issanni-NAT-Type NAT 1
+VALUE Issanni-NAT-Type NAPT 2
+
+END-VENDOR Issanni
+# -*- text -*-
#
# http://www.digieurope.com/
# $Id$
#
-VENDOR ITK 1195
+VENDOR ITK 1195
-ATTRIBUTE ITK-Auth-Serv-IP 100 ipaddr ITK
-ATTRIBUTE ITK-Auth-Serv-Prot 101 integer ITK
-ATTRIBUTE ITK-Provider-Id 102 integer ITK
-ATTRIBUTE ITK-Usergroup 103 integer ITK
-ATTRIBUTE ITK-Banner 104 string ITK
-ATTRIBUTE ITK-Username-Prompt 105 string ITK
-ATTRIBUTE ITK-Password-Prompt 106 string ITK
-ATTRIBUTE ITK-Welcome-Message 107 string ITK
-ATTRIBUTE ITK-Prompt 108 string ITK
-ATTRIBUTE ITK-IP-Pool 109 integer ITK
-ATTRIBUTE ITK-Tunnel-IP 110 ipaddr ITK
-ATTRIBUTE ITK-Tunnel-Prot 111 integer ITK
-ATTRIBUTE ITK-Acct-Serv-IP 112 ipaddr ITK
-ATTRIBUTE ITK-Acct-Serv-Prot 113 integer ITK
-ATTRIBUTE ITK-Filter-Rule 114 string ITK
-ATTRIBUTE ITK-Channel-Binding 115 integer ITK
-ATTRIBUTE ITK-Start-Delay 116 integer ITK
-ATTRIBUTE ITK-NAS-Name 117 string ITK
-ATTRIBUTE ITK-ISDN-Prot 118 integer ITK
-ATTRIBUTE ITK-PPP-Auth-Type 119 integer ITK
-ATTRIBUTE ITK-Dialout-Type 120 integer ITK
-ATTRIBUTE ITK-Ftp-Auth-IP 121 ipaddr ITK
-ATTRIBUTE ITK-Users-Default-Entry 122 string ITK
-ATTRIBUTE ITK-Users-Default-Pw 123 string ITK
-ATTRIBUTE ITK-Auth-Req-Type 124 string ITK
-ATTRIBUTE ITK-Modem-Pool-Id 125 integer ITK
-ATTRIBUTE ITK-Modem-Init-String 126 string ITK
-ATTRIBUTE ITK-PPP-Client-Server-Mode 127 integer ITK
-ATTRIBUTE ITK-PPP-Compression-Prot 128 string ITK
-ATTRIBUTE ITK-Username 129 string ITK
-ATTRIBUTE ITK-Dest-No 130 string ITK
-ATTRIBUTE ITK-DDI 131 string ITK
+BEGIN-VENDOR ITK
+
+ATTRIBUTE ITK-Auth-Serv-IP 100 ipaddr
+ATTRIBUTE ITK-Auth-Serv-Prot 101 integer
+ATTRIBUTE ITK-Provider-Id 102 integer
+ATTRIBUTE ITK-Usergroup 103 integer
+ATTRIBUTE ITK-Banner 104 string
+ATTRIBUTE ITK-Username-Prompt 105 string
+ATTRIBUTE ITK-Password-Prompt 106 string
+ATTRIBUTE ITK-Welcome-Message 107 string
+ATTRIBUTE ITK-Prompt 108 string
+ATTRIBUTE ITK-IP-Pool 109 integer
+ATTRIBUTE ITK-Tunnel-IP 110 ipaddr
+ATTRIBUTE ITK-Tunnel-Prot 111 integer
+ATTRIBUTE ITK-Acct-Serv-IP 112 ipaddr
+ATTRIBUTE ITK-Acct-Serv-Prot 113 integer
+ATTRIBUTE ITK-Filter-Rule 114 string
+ATTRIBUTE ITK-Channel-Binding 115 integer
+ATTRIBUTE ITK-Start-Delay 116 integer
+ATTRIBUTE ITK-NAS-Name 117 string
+ATTRIBUTE ITK-ISDN-Prot 118 integer
+ATTRIBUTE ITK-PPP-Auth-Type 119 integer
+ATTRIBUTE ITK-Dialout-Type 120 integer
+ATTRIBUTE ITK-Ftp-Auth-IP 121 ipaddr
+ATTRIBUTE ITK-Users-Default-Entry 122 string
+ATTRIBUTE ITK-Users-Default-Pw 123 string
+ATTRIBUTE ITK-Auth-Req-Type 124 string
+ATTRIBUTE ITK-Modem-Pool-Id 125 integer
+ATTRIBUTE ITK-Modem-Init-String 126 string
+ATTRIBUTE ITK-PPP-Client-Server-Mode 127 integer
+ATTRIBUTE ITK-PPP-Compression-Prot 128 string
+ATTRIBUTE ITK-Username 129 string
+ATTRIBUTE ITK-Dest-No 130 string
+ATTRIBUTE ITK-DDI 131 string
+
+END-VENDOR ITK
+# -*- text -*-
#
# dictionary.juniper
#
# Version: $Id$
#
-VENDOR Juniper 2636
+VENDOR Juniper 2636
-ATTRIBUTE Juniper-Local-User-Name 1 string Juniper
-ATTRIBUTE Juniper-Allow-Commands 2 string Juniper
-ATTRIBUTE Juniper-Deny-Commands 3 string Juniper
-ATTRIBUTE Juniper-Allow-Configuration 4 string Juniper
-ATTRIBUTE Juniper-Deny-Configuration 5 string Juniper
+BEGIN-VENDOR Juniper
+
+ATTRIBUTE Juniper-Local-User-Name 1 string
+ATTRIBUTE Juniper-Allow-Commands 2 string
+ATTRIBUTE Juniper-Deny-Commands 3 string
+ATTRIBUTE Juniper-Allow-Configuration 4 string
+ATTRIBUTE Juniper-Deny-Configuration 5 string
+
+END-VENDOR Juniper
-# --------------------------------------\r
-# KarlNet Vendor-specific information\r
-# --------------------------------------\r
-\r
-#---------------------------------------------------------------------------\r
-# "VENDOR" VENDOR-NAME VENDOR-ID\r
-#---------------------------------------------------------------------------\r
-VENDOR KarlNet 762\r
-\r
-#---------------------------------------------------------------------------\r
-# "ATTRIBUTE" ATTRIBUTE-NAME ATTR-NUMBER ATTRTYPE VENDOR-NAME\r
-#---------------------------------------------------------------------------\r
-# Sets the remote client's Station Name\r
-ATTRIBUTE KarlNet-TurboCell-Name 151 string KarlNet\r
-\r
-# Sets the remote client's Data Transmit Rate\r
-ATTRIBUTE KarlNet-TurboCell-TxRate 152 integer KarlNet\r
-\r
-#---------------------------------------------------------------------------\r
-# "VALUE" ATTRIBUTE-NAME SETTING-NAME SETTING-VALUE\r
-#---------------------------------------------------------------------------\r
-# 0x00 // Use the locally defined Data Rate\r
-VALUE KarlNet-TurboCell-TxRate TxRate-Local 0 \r
-# 0x08 // Use the maximum data rate possible \r
-VALUE KarlNet-TurboCell-TxRate TxRate-MaxSpeed 8 \r
-\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11k 11\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12k 12\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13k 13\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14k 14\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15k 15\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16k 16\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17k 17\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18k 18\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19k 19\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20k 20\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21k 21\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22k 22\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23k 23\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24k 24\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25k 25\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26k 26\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27k 27\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28k 28\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29k 29\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30k 30\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31k 31\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32k 32\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33k 33\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34k 34\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35k 35\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36k 36\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37k 37\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38k 38\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39k 39\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40k 40\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41k 41\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42k 42\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43k 43\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44k 44\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45k 45\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46k 46\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47k 47\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48k 48\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49k 49\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50k 50\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51k 51\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52k 52\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53k 53\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54k 54\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55k 55\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56k 56\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57k 57\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58k 58\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59k 59\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60k 60\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61k 61\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62k 62\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63k 63\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64k 64\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65k 65\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66k 66\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67k 67\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68k 68\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69k 69\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70k 70\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71k 71\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72k 72\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73k 73\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74k 74\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75k 75\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76k 76\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77k 77\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78k 78\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79k 79\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80k 80\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81k 81\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82k 82\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83k 83\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84k 84\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85k 85\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86k 86\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87k 87\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88k 88\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89k 89\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90k 90\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91k 91\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92k 92\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93k 93\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94k 94\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95k 95\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96k 96\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97k 97\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98k 98\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99k 99\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100k 100\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101k 101\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102k 102\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103k 103\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104k 104\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105k 105\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106k 106\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107k 107\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108k 108\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109k 109\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110k 110\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111k 111\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112k 112\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113k 113\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114k 114\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115k 115\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116k 116\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117k 117\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118k 118\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119k 119\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120k 120\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121k 121\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122k 122\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123k 123\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124k 124\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125k 125\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126k 126\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127k 127\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128k 128\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129k 129\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130k 130\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131k 131\r
-VALUE KarlNet-TurboCell-TxRate TxRate-132k 132\r
-VALUE KarlNet-TurboCell-TxRate TxRate-133k 133\r
-VALUE KarlNet-TurboCell-TxRate TxRate-134k 134\r
-VALUE KarlNet-TurboCell-TxRate TxRate-135k 135\r
-VALUE KarlNet-TurboCell-TxRate TxRate-136k 136\r
-VALUE KarlNet-TurboCell-TxRate TxRate-137k 137\r
-VALUE KarlNet-TurboCell-TxRate TxRate-138k 138\r
-VALUE KarlNet-TurboCell-TxRate TxRate-139k 139\r
-VALUE KarlNet-TurboCell-TxRate TxRate-140k 140\r
-VALUE KarlNet-TurboCell-TxRate TxRate-141k 141\r
-VALUE KarlNet-TurboCell-TxRate TxRate-142k 142\r
-VALUE KarlNet-TurboCell-TxRate TxRate-143k 143\r
-VALUE KarlNet-TurboCell-TxRate TxRate-144k 144\r
-VALUE KarlNet-TurboCell-TxRate TxRate-145k 145\r
-VALUE KarlNet-TurboCell-TxRate TxRate-146k 146\r
-VALUE KarlNet-TurboCell-TxRate TxRate-147k 147\r
-VALUE KarlNet-TurboCell-TxRate TxRate-148k 148\r
-VALUE KarlNet-TurboCell-TxRate TxRate-149k 149\r
-VALUE KarlNet-TurboCell-TxRate TxRate-150k 150\r
-VALUE KarlNet-TurboCell-TxRate TxRate-151k 151\r
-VALUE KarlNet-TurboCell-TxRate TxRate-152k 152\r
-VALUE KarlNet-TurboCell-TxRate TxRate-153k 153\r
-VALUE KarlNet-TurboCell-TxRate TxRate-154k 154\r
-VALUE KarlNet-TurboCell-TxRate TxRate-155k 155\r
-VALUE KarlNet-TurboCell-TxRate TxRate-156k 156\r
-VALUE KarlNet-TurboCell-TxRate TxRate-157k 157\r
-VALUE KarlNet-TurboCell-TxRate TxRate-158k 158\r
-VALUE KarlNet-TurboCell-TxRate TxRate-159k 159\r
-VALUE KarlNet-TurboCell-TxRate TxRate-160k 160\r
-VALUE KarlNet-TurboCell-TxRate TxRate-161k 161\r
-VALUE KarlNet-TurboCell-TxRate TxRate-162k 162\r
-VALUE KarlNet-TurboCell-TxRate TxRate-163k 163\r
-VALUE KarlNet-TurboCell-TxRate TxRate-164k 164\r
-VALUE KarlNet-TurboCell-TxRate TxRate-165k 165\r
-VALUE KarlNet-TurboCell-TxRate TxRate-166k 166\r
-VALUE KarlNet-TurboCell-TxRate TxRate-167k 167\r
-VALUE KarlNet-TurboCell-TxRate TxRate-168k 168\r
-VALUE KarlNet-TurboCell-TxRate TxRate-169k 169\r
-VALUE KarlNet-TurboCell-TxRate TxRate-170k 170\r
-VALUE KarlNet-TurboCell-TxRate TxRate-171k 171\r
-VALUE KarlNet-TurboCell-TxRate TxRate-172k 172\r
-VALUE KarlNet-TurboCell-TxRate TxRate-173k 173\r
-VALUE KarlNet-TurboCell-TxRate TxRate-174k 174\r
-VALUE KarlNet-TurboCell-TxRate TxRate-175k 175\r
-VALUE KarlNet-TurboCell-TxRate TxRate-176k 176\r
-VALUE KarlNet-TurboCell-TxRate TxRate-177k 177\r
-VALUE KarlNet-TurboCell-TxRate TxRate-178k 178\r
-VALUE KarlNet-TurboCell-TxRate TxRate-179k 179\r
-VALUE KarlNet-TurboCell-TxRate TxRate-180k 180\r
-VALUE KarlNet-TurboCell-TxRate TxRate-181k 181\r
-VALUE KarlNet-TurboCell-TxRate TxRate-182k 182\r
-VALUE KarlNet-TurboCell-TxRate TxRate-183k 183\r
-VALUE KarlNet-TurboCell-TxRate TxRate-184k 184\r
-VALUE KarlNet-TurboCell-TxRate TxRate-185k 185\r
-VALUE KarlNet-TurboCell-TxRate TxRate-186k 186\r
-VALUE KarlNet-TurboCell-TxRate TxRate-187k 187\r
-VALUE KarlNet-TurboCell-TxRate TxRate-188k 188\r
-VALUE KarlNet-TurboCell-TxRate TxRate-189k 189\r
-VALUE KarlNet-TurboCell-TxRate TxRate-190k 190\r
-VALUE KarlNet-TurboCell-TxRate TxRate-191k 191\r
-VALUE KarlNet-TurboCell-TxRate TxRate-192k 192\r
-VALUE KarlNet-TurboCell-TxRate TxRate-193k 193\r
-VALUE KarlNet-TurboCell-TxRate TxRate-194k 194\r
-VALUE KarlNet-TurboCell-TxRate TxRate-195k 195\r
-VALUE KarlNet-TurboCell-TxRate TxRate-196k 196\r
-VALUE KarlNet-TurboCell-TxRate TxRate-197k 197\r
-VALUE KarlNet-TurboCell-TxRate TxRate-198k 198\r
-VALUE KarlNet-TurboCell-TxRate TxRate-199k 199\r
-VALUE KarlNet-TurboCell-TxRate TxRate-200k 200\r
-VALUE KarlNet-TurboCell-TxRate TxRate-201k 201\r
-VALUE KarlNet-TurboCell-TxRate TxRate-202k 202\r
-VALUE KarlNet-TurboCell-TxRate TxRate-203k 203\r
-VALUE KarlNet-TurboCell-TxRate TxRate-204k 204\r
-VALUE KarlNet-TurboCell-TxRate TxRate-205k 205\r
-VALUE KarlNet-TurboCell-TxRate TxRate-206k 206\r
-VALUE KarlNet-TurboCell-TxRate TxRate-207k 207\r
-VALUE KarlNet-TurboCell-TxRate TxRate-208k 208\r
-VALUE KarlNet-TurboCell-TxRate TxRate-209k 209\r
-VALUE KarlNet-TurboCell-TxRate TxRate-210k 210\r
-VALUE KarlNet-TurboCell-TxRate TxRate-211k 211\r
-VALUE KarlNet-TurboCell-TxRate TxRate-212k 212\r
-VALUE KarlNet-TurboCell-TxRate TxRate-213k 213\r
-VALUE KarlNet-TurboCell-TxRate TxRate-214k 214\r
-VALUE KarlNet-TurboCell-TxRate TxRate-215k 215\r
-VALUE KarlNet-TurboCell-TxRate TxRate-216k 216\r
-VALUE KarlNet-TurboCell-TxRate TxRate-217k 217\r
-VALUE KarlNet-TurboCell-TxRate TxRate-218k 218\r
-VALUE KarlNet-TurboCell-TxRate TxRate-219k 219\r
-VALUE KarlNet-TurboCell-TxRate TxRate-220k 220\r
-VALUE KarlNet-TurboCell-TxRate TxRate-221k 221\r
-VALUE KarlNet-TurboCell-TxRate TxRate-222k 222\r
-VALUE KarlNet-TurboCell-TxRate TxRate-223k 223\r
-VALUE KarlNet-TurboCell-TxRate TxRate-224k 224\r
-VALUE KarlNet-TurboCell-TxRate TxRate-225k 225\r
-VALUE KarlNet-TurboCell-TxRate TxRate-226k 226\r
-VALUE KarlNet-TurboCell-TxRate TxRate-227k 227\r
-VALUE KarlNet-TurboCell-TxRate TxRate-228k 228\r
-VALUE KarlNet-TurboCell-TxRate TxRate-229k 229\r
-VALUE KarlNet-TurboCell-TxRate TxRate-230k 230\r
-VALUE KarlNet-TurboCell-TxRate TxRate-231k 231\r
-VALUE KarlNet-TurboCell-TxRate TxRate-232k 232\r
-VALUE KarlNet-TurboCell-TxRate TxRate-233k 233\r
-VALUE KarlNet-TurboCell-TxRate TxRate-234k 234\r
-VALUE KarlNet-TurboCell-TxRate TxRate-235k 235\r
-VALUE KarlNet-TurboCell-TxRate TxRate-236k 236\r
-VALUE KarlNet-TurboCell-TxRate TxRate-237k 237\r
-VALUE KarlNet-TurboCell-TxRate TxRate-238k 238\r
-VALUE KarlNet-TurboCell-TxRate TxRate-239k 239\r
-VALUE KarlNet-TurboCell-TxRate TxRate-240k 240\r
-VALUE KarlNet-TurboCell-TxRate TxRate-241k 241\r
-VALUE KarlNet-TurboCell-TxRate TxRate-242k 242\r
-VALUE KarlNet-TurboCell-TxRate TxRate-243k 243\r
-VALUE KarlNet-TurboCell-TxRate TxRate-244k 244\r
-VALUE KarlNet-TurboCell-TxRate TxRate-245k 245\r
-VALUE KarlNet-TurboCell-TxRate TxRate-246k 246\r
-VALUE KarlNet-TurboCell-TxRate TxRate-247k 247\r
-VALUE KarlNet-TurboCell-TxRate TxRate-248k 248\r
-VALUE KarlNet-TurboCell-TxRate TxRate-249k 249\r
-VALUE KarlNet-TurboCell-TxRate TxRate-250k 250\r
-VALUE KarlNet-TurboCell-TxRate TxRate-251k 251\r
-VALUE KarlNet-TurboCell-TxRate TxRate-252k 252\r
-VALUE KarlNet-TurboCell-TxRate TxRate-253k 253\r
-VALUE KarlNet-TurboCell-TxRate TxRate-254k 254\r
-VALUE KarlNet-TurboCell-TxRate TxRate-255k 255\r
-VALUE KarlNet-TurboCell-TxRate TxRate-256k 256\r
-VALUE KarlNet-TurboCell-TxRate TxRate-257k 257\r
-VALUE KarlNet-TurboCell-TxRate TxRate-258k 258\r
-VALUE KarlNet-TurboCell-TxRate TxRate-259k 259\r
-VALUE KarlNet-TurboCell-TxRate TxRate-260k 260\r
-VALUE KarlNet-TurboCell-TxRate TxRate-261k 261\r
-VALUE KarlNet-TurboCell-TxRate TxRate-262k 262\r
-VALUE KarlNet-TurboCell-TxRate TxRate-263k 263\r
-VALUE KarlNet-TurboCell-TxRate TxRate-264k 264\r
-VALUE KarlNet-TurboCell-TxRate TxRate-265k 265\r
-VALUE KarlNet-TurboCell-TxRate TxRate-266k 266\r
-VALUE KarlNet-TurboCell-TxRate TxRate-267k 267\r
-VALUE KarlNet-TurboCell-TxRate TxRate-268k 268\r
-VALUE KarlNet-TurboCell-TxRate TxRate-269k 269\r
-VALUE KarlNet-TurboCell-TxRate TxRate-270k 270\r
-VALUE KarlNet-TurboCell-TxRate TxRate-271k 271\r
-VALUE KarlNet-TurboCell-TxRate TxRate-272k 272\r
-VALUE KarlNet-TurboCell-TxRate TxRate-273k 273\r
-VALUE KarlNet-TurboCell-TxRate TxRate-274k 274\r
-VALUE KarlNet-TurboCell-TxRate TxRate-275k 275\r
-VALUE KarlNet-TurboCell-TxRate TxRate-276k 276\r
-VALUE KarlNet-TurboCell-TxRate TxRate-277k 277\r
-VALUE KarlNet-TurboCell-TxRate TxRate-278k 278\r
-VALUE KarlNet-TurboCell-TxRate TxRate-279k 279\r
-VALUE KarlNet-TurboCell-TxRate TxRate-280k 280\r
-VALUE KarlNet-TurboCell-TxRate TxRate-281k 281\r
-VALUE KarlNet-TurboCell-TxRate TxRate-282k 282\r
-VALUE KarlNet-TurboCell-TxRate TxRate-283k 283\r
-VALUE KarlNet-TurboCell-TxRate TxRate-284k 284\r
-VALUE KarlNet-TurboCell-TxRate TxRate-285k 285\r
-VALUE KarlNet-TurboCell-TxRate TxRate-286k 286\r
-VALUE KarlNet-TurboCell-TxRate TxRate-287k 287\r
-VALUE KarlNet-TurboCell-TxRate TxRate-288k 288\r
-VALUE KarlNet-TurboCell-TxRate TxRate-289k 289\r
-VALUE KarlNet-TurboCell-TxRate TxRate-290k 290\r
-VALUE KarlNet-TurboCell-TxRate TxRate-291k 291\r
-VALUE KarlNet-TurboCell-TxRate TxRate-292k 292\r
-VALUE KarlNet-TurboCell-TxRate TxRate-293k 293\r
-VALUE KarlNet-TurboCell-TxRate TxRate-294k 294\r
-VALUE KarlNet-TurboCell-TxRate TxRate-295k 295\r
-VALUE KarlNet-TurboCell-TxRate TxRate-296k 296\r
-VALUE KarlNet-TurboCell-TxRate TxRate-297k 297\r
-VALUE KarlNet-TurboCell-TxRate TxRate-298k 298\r
-VALUE KarlNet-TurboCell-TxRate TxRate-299k 299\r
-VALUE KarlNet-TurboCell-TxRate TxRate-300k 300\r
-VALUE KarlNet-TurboCell-TxRate TxRate-301k 301\r
-VALUE KarlNet-TurboCell-TxRate TxRate-302k 302\r
-VALUE KarlNet-TurboCell-TxRate TxRate-303k 303\r
-VALUE KarlNet-TurboCell-TxRate TxRate-304k 304\r
-VALUE KarlNet-TurboCell-TxRate TxRate-305k 305\r
-VALUE KarlNet-TurboCell-TxRate TxRate-306k 306\r
-VALUE KarlNet-TurboCell-TxRate TxRate-307k 307\r
-VALUE KarlNet-TurboCell-TxRate TxRate-308k 308\r
-VALUE KarlNet-TurboCell-TxRate TxRate-309k 309\r
-VALUE KarlNet-TurboCell-TxRate TxRate-310k 310\r
-VALUE KarlNet-TurboCell-TxRate TxRate-311k 311\r
-VALUE KarlNet-TurboCell-TxRate TxRate-312k 312\r
-VALUE KarlNet-TurboCell-TxRate TxRate-313k 313\r
-VALUE KarlNet-TurboCell-TxRate TxRate-314k 314\r
-VALUE KarlNet-TurboCell-TxRate TxRate-315k 315\r
-VALUE KarlNet-TurboCell-TxRate TxRate-316k 316\r
-VALUE KarlNet-TurboCell-TxRate TxRate-317k 317\r
-VALUE KarlNet-TurboCell-TxRate TxRate-318k 318\r
-VALUE KarlNet-TurboCell-TxRate TxRate-319k 319\r
-VALUE KarlNet-TurboCell-TxRate TxRate-320k 320\r
-VALUE KarlNet-TurboCell-TxRate TxRate-321k 321\r
-VALUE KarlNet-TurboCell-TxRate TxRate-322k 322\r
-VALUE KarlNet-TurboCell-TxRate TxRate-323k 323\r
-VALUE KarlNet-TurboCell-TxRate TxRate-324k 324\r
-VALUE KarlNet-TurboCell-TxRate TxRate-325k 325\r
-VALUE KarlNet-TurboCell-TxRate TxRate-326k 326\r
-VALUE KarlNet-TurboCell-TxRate TxRate-327k 327\r
-VALUE KarlNet-TurboCell-TxRate TxRate-328k 328\r
-VALUE KarlNet-TurboCell-TxRate TxRate-329k 329\r
-VALUE KarlNet-TurboCell-TxRate TxRate-330k 330\r
-VALUE KarlNet-TurboCell-TxRate TxRate-331k 331\r
-VALUE KarlNet-TurboCell-TxRate TxRate-332k 332\r
-VALUE KarlNet-TurboCell-TxRate TxRate-333k 333\r
-VALUE KarlNet-TurboCell-TxRate TxRate-334k 334\r
-VALUE KarlNet-TurboCell-TxRate TxRate-335k 335\r
-VALUE KarlNet-TurboCell-TxRate TxRate-336k 336\r
-VALUE KarlNet-TurboCell-TxRate TxRate-337k 337\r
-VALUE KarlNet-TurboCell-TxRate TxRate-338k 338\r
-VALUE KarlNet-TurboCell-TxRate TxRate-339k 339\r
-VALUE KarlNet-TurboCell-TxRate TxRate-340k 340\r
-VALUE KarlNet-TurboCell-TxRate TxRate-341k 341\r
-VALUE KarlNet-TurboCell-TxRate TxRate-342k 342\r
-VALUE KarlNet-TurboCell-TxRate TxRate-343k 343\r
-VALUE KarlNet-TurboCell-TxRate TxRate-344k 344\r
-VALUE KarlNet-TurboCell-TxRate TxRate-345k 345\r
-VALUE KarlNet-TurboCell-TxRate TxRate-346k 346\r
-VALUE KarlNet-TurboCell-TxRate TxRate-347k 347\r
-VALUE KarlNet-TurboCell-TxRate TxRate-348k 348\r
-VALUE KarlNet-TurboCell-TxRate TxRate-349k 349\r
-VALUE KarlNet-TurboCell-TxRate TxRate-350k 350\r
-VALUE KarlNet-TurboCell-TxRate TxRate-351k 351\r
-VALUE KarlNet-TurboCell-TxRate TxRate-352k 352\r
-VALUE KarlNet-TurboCell-TxRate TxRate-353k 353\r
-VALUE KarlNet-TurboCell-TxRate TxRate-354k 354\r
-VALUE KarlNet-TurboCell-TxRate TxRate-355k 355\r
-VALUE KarlNet-TurboCell-TxRate TxRate-356k 356\r
-VALUE KarlNet-TurboCell-TxRate TxRate-357k 357\r
-VALUE KarlNet-TurboCell-TxRate TxRate-358k 358\r
-VALUE KarlNet-TurboCell-TxRate TxRate-359k 359\r
-VALUE KarlNet-TurboCell-TxRate TxRate-360k 360\r
-VALUE KarlNet-TurboCell-TxRate TxRate-361k 361\r
-VALUE KarlNet-TurboCell-TxRate TxRate-362k 362\r
-VALUE KarlNet-TurboCell-TxRate TxRate-363k 363\r
-VALUE KarlNet-TurboCell-TxRate TxRate-364k 364\r
-VALUE KarlNet-TurboCell-TxRate TxRate-365k 365\r
-VALUE KarlNet-TurboCell-TxRate TxRate-366k 366\r
-VALUE KarlNet-TurboCell-TxRate TxRate-367k 367\r
-VALUE KarlNet-TurboCell-TxRate TxRate-368k 368\r
-VALUE KarlNet-TurboCell-TxRate TxRate-369k 369\r
-VALUE KarlNet-TurboCell-TxRate TxRate-370k 370\r
-VALUE KarlNet-TurboCell-TxRate TxRate-371k 371\r
-VALUE KarlNet-TurboCell-TxRate TxRate-372k 372\r
-VALUE KarlNet-TurboCell-TxRate TxRate-373k 373\r
-VALUE KarlNet-TurboCell-TxRate TxRate-374k 374\r
-VALUE KarlNet-TurboCell-TxRate TxRate-375k 375\r
-VALUE KarlNet-TurboCell-TxRate TxRate-376k 376\r
-VALUE KarlNet-TurboCell-TxRate TxRate-377k 377\r
-VALUE KarlNet-TurboCell-TxRate TxRate-378k 378\r
-VALUE KarlNet-TurboCell-TxRate TxRate-379k 379\r
-VALUE KarlNet-TurboCell-TxRate TxRate-380k 380\r
-VALUE KarlNet-TurboCell-TxRate TxRate-381k 381\r
-VALUE KarlNet-TurboCell-TxRate TxRate-382k 382\r
-VALUE KarlNet-TurboCell-TxRate TxRate-383k 383\r
-VALUE KarlNet-TurboCell-TxRate TxRate-384k 384\r
-VALUE KarlNet-TurboCell-TxRate TxRate-385k 385\r
-VALUE KarlNet-TurboCell-TxRate TxRate-386k 386\r
-VALUE KarlNet-TurboCell-TxRate TxRate-387k 387\r
-VALUE KarlNet-TurboCell-TxRate TxRate-388k 388\r
-VALUE KarlNet-TurboCell-TxRate TxRate-389k 389\r
-VALUE KarlNet-TurboCell-TxRate TxRate-390k 390\r
-VALUE KarlNet-TurboCell-TxRate TxRate-391k 391\r
-VALUE KarlNet-TurboCell-TxRate TxRate-392k 392\r
-VALUE KarlNet-TurboCell-TxRate TxRate-393k 393\r
-VALUE KarlNet-TurboCell-TxRate TxRate-394k 394\r
-VALUE KarlNet-TurboCell-TxRate TxRate-395k 395\r
-VALUE KarlNet-TurboCell-TxRate TxRate-396k 396\r
-VALUE KarlNet-TurboCell-TxRate TxRate-397k 397\r
-VALUE KarlNet-TurboCell-TxRate TxRate-398k 398\r
-VALUE KarlNet-TurboCell-TxRate TxRate-399k 399\r
-VALUE KarlNet-TurboCell-TxRate TxRate-400k 400\r
-VALUE KarlNet-TurboCell-TxRate TxRate-401k 401\r
-VALUE KarlNet-TurboCell-TxRate TxRate-402k 402\r
-VALUE KarlNet-TurboCell-TxRate TxRate-403k 403\r
-VALUE KarlNet-TurboCell-TxRate TxRate-404k 404\r
-VALUE KarlNet-TurboCell-TxRate TxRate-405k 405\r
-VALUE KarlNet-TurboCell-TxRate TxRate-406k 406\r
-VALUE KarlNet-TurboCell-TxRate TxRate-407k 407\r
-VALUE KarlNet-TurboCell-TxRate TxRate-408k 408\r
-VALUE KarlNet-TurboCell-TxRate TxRate-409k 409\r
-VALUE KarlNet-TurboCell-TxRate TxRate-410k 410\r
-VALUE KarlNet-TurboCell-TxRate TxRate-411k 411\r
-VALUE KarlNet-TurboCell-TxRate TxRate-412k 412\r
-VALUE KarlNet-TurboCell-TxRate TxRate-413k 413\r
-VALUE KarlNet-TurboCell-TxRate TxRate-414k 414\r
-VALUE KarlNet-TurboCell-TxRate TxRate-415k 415\r
-VALUE KarlNet-TurboCell-TxRate TxRate-416k 416\r
-VALUE KarlNet-TurboCell-TxRate TxRate-417k 417\r
-VALUE KarlNet-TurboCell-TxRate TxRate-418k 418\r
-VALUE KarlNet-TurboCell-TxRate TxRate-419k 419\r
-VALUE KarlNet-TurboCell-TxRate TxRate-420k 420\r
-VALUE KarlNet-TurboCell-TxRate TxRate-421k 421\r
-VALUE KarlNet-TurboCell-TxRate TxRate-422k 422\r
-VALUE KarlNet-TurboCell-TxRate TxRate-423k 423\r
-VALUE KarlNet-TurboCell-TxRate TxRate-424k 424\r
-VALUE KarlNet-TurboCell-TxRate TxRate-425k 425\r
-VALUE KarlNet-TurboCell-TxRate TxRate-426k 426\r
-VALUE KarlNet-TurboCell-TxRate TxRate-427k 427\r
-VALUE KarlNet-TurboCell-TxRate TxRate-428k 428\r
-VALUE KarlNet-TurboCell-TxRate TxRate-429k 429\r
-VALUE KarlNet-TurboCell-TxRate TxRate-430k 430\r
-VALUE KarlNet-TurboCell-TxRate TxRate-431k 431\r
-VALUE KarlNet-TurboCell-TxRate TxRate-432k 432\r
-VALUE KarlNet-TurboCell-TxRate TxRate-433k 433\r
-VALUE KarlNet-TurboCell-TxRate TxRate-434k 434\r
-VALUE KarlNet-TurboCell-TxRate TxRate-435k 435\r
-VALUE KarlNet-TurboCell-TxRate TxRate-436k 436\r
-VALUE KarlNet-TurboCell-TxRate TxRate-437k 437\r
-VALUE KarlNet-TurboCell-TxRate TxRate-438k 438\r
-VALUE KarlNet-TurboCell-TxRate TxRate-439k 439\r
-VALUE KarlNet-TurboCell-TxRate TxRate-440k 440\r
-VALUE KarlNet-TurboCell-TxRate TxRate-441k 441\r
-VALUE KarlNet-TurboCell-TxRate TxRate-442k 442\r
-VALUE KarlNet-TurboCell-TxRate TxRate-443k 443\r
-VALUE KarlNet-TurboCell-TxRate TxRate-444k 444\r
-VALUE KarlNet-TurboCell-TxRate TxRate-445k 445\r
-VALUE KarlNet-TurboCell-TxRate TxRate-446k 446\r
-VALUE KarlNet-TurboCell-TxRate TxRate-447k 447\r
-VALUE KarlNet-TurboCell-TxRate TxRate-448k 448\r
-VALUE KarlNet-TurboCell-TxRate TxRate-449k 449\r
-VALUE KarlNet-TurboCell-TxRate TxRate-450k 450\r
-VALUE KarlNet-TurboCell-TxRate TxRate-451k 451\r
-VALUE KarlNet-TurboCell-TxRate TxRate-452k 452\r
-VALUE KarlNet-TurboCell-TxRate TxRate-453k 453\r
-VALUE KarlNet-TurboCell-TxRate TxRate-454k 454\r
-VALUE KarlNet-TurboCell-TxRate TxRate-455k 455\r
-VALUE KarlNet-TurboCell-TxRate TxRate-456k 456\r
-VALUE KarlNet-TurboCell-TxRate TxRate-457k 457\r
-VALUE KarlNet-TurboCell-TxRate TxRate-458k 458\r
-VALUE KarlNet-TurboCell-TxRate TxRate-459k 459\r
-VALUE KarlNet-TurboCell-TxRate TxRate-460k 460\r
-VALUE KarlNet-TurboCell-TxRate TxRate-461k 461\r
-VALUE KarlNet-TurboCell-TxRate TxRate-462k 462\r
-VALUE KarlNet-TurboCell-TxRate TxRate-463k 463\r
-VALUE KarlNet-TurboCell-TxRate TxRate-464k 464\r
-VALUE KarlNet-TurboCell-TxRate TxRate-465k 465\r
-VALUE KarlNet-TurboCell-TxRate TxRate-466k 466\r
-VALUE KarlNet-TurboCell-TxRate TxRate-467k 467\r
-VALUE KarlNet-TurboCell-TxRate TxRate-468k 468\r
-VALUE KarlNet-TurboCell-TxRate TxRate-469k 469\r
-VALUE KarlNet-TurboCell-TxRate TxRate-470k 470\r
-VALUE KarlNet-TurboCell-TxRate TxRate-471k 471\r
-VALUE KarlNet-TurboCell-TxRate TxRate-472k 472\r
-VALUE KarlNet-TurboCell-TxRate TxRate-473k 473\r
-VALUE KarlNet-TurboCell-TxRate TxRate-474k 474\r
-VALUE KarlNet-TurboCell-TxRate TxRate-475k 475\r
-VALUE KarlNet-TurboCell-TxRate TxRate-476k 476\r
-VALUE KarlNet-TurboCell-TxRate TxRate-477k 477\r
-VALUE KarlNet-TurboCell-TxRate TxRate-478k 478\r
-VALUE KarlNet-TurboCell-TxRate TxRate-479k 479\r
-VALUE KarlNet-TurboCell-TxRate TxRate-480k 480\r
-VALUE KarlNet-TurboCell-TxRate TxRate-481k 481\r
-VALUE KarlNet-TurboCell-TxRate TxRate-482k 482\r
-VALUE KarlNet-TurboCell-TxRate TxRate-483k 483\r
-VALUE KarlNet-TurboCell-TxRate TxRate-484k 484\r
-VALUE KarlNet-TurboCell-TxRate TxRate-485k 485\r
-VALUE KarlNet-TurboCell-TxRate TxRate-486k 486\r
-VALUE KarlNet-TurboCell-TxRate TxRate-487k 487\r
-VALUE KarlNet-TurboCell-TxRate TxRate-488k 488\r
-VALUE KarlNet-TurboCell-TxRate TxRate-489k 489\r
-VALUE KarlNet-TurboCell-TxRate TxRate-490k 490\r
-VALUE KarlNet-TurboCell-TxRate TxRate-491k 491\r
-VALUE KarlNet-TurboCell-TxRate TxRate-492k 492\r
-VALUE KarlNet-TurboCell-TxRate TxRate-493k 493\r
-VALUE KarlNet-TurboCell-TxRate TxRate-494k 494\r
-VALUE KarlNet-TurboCell-TxRate TxRate-495k 495\r
-VALUE KarlNet-TurboCell-TxRate TxRate-496k 496\r
-VALUE KarlNet-TurboCell-TxRate TxRate-497k 497\r
-VALUE KarlNet-TurboCell-TxRate TxRate-498k 498\r
-VALUE KarlNet-TurboCell-TxRate TxRate-499k 499\r
-VALUE KarlNet-TurboCell-TxRate TxRate-500k 500\r
-VALUE KarlNet-TurboCell-TxRate TxRate-501k 501\r
-VALUE KarlNet-TurboCell-TxRate TxRate-502k 502\r
-VALUE KarlNet-TurboCell-TxRate TxRate-503k 503\r
-VALUE KarlNet-TurboCell-TxRate TxRate-504k 504\r
-VALUE KarlNet-TurboCell-TxRate TxRate-505k 505\r
-VALUE KarlNet-TurboCell-TxRate TxRate-506k 506\r
-VALUE KarlNet-TurboCell-TxRate TxRate-507k 507\r
-VALUE KarlNet-TurboCell-TxRate TxRate-508k 508\r
-VALUE KarlNet-TurboCell-TxRate TxRate-509k 509\r
-VALUE KarlNet-TurboCell-TxRate TxRate-510k 510\r
-VALUE KarlNet-TurboCell-TxRate TxRate-511k 511\r
-VALUE KarlNet-TurboCell-TxRate TxRate-512k 512\r
-VALUE KarlNet-TurboCell-TxRate TxRate-513k 513\r
-VALUE KarlNet-TurboCell-TxRate TxRate-514k 514\r
-VALUE KarlNet-TurboCell-TxRate TxRate-515k 515\r
-VALUE KarlNet-TurboCell-TxRate TxRate-516k 516\r
-VALUE KarlNet-TurboCell-TxRate TxRate-517k 517\r
-VALUE KarlNet-TurboCell-TxRate TxRate-518k 518\r
-VALUE KarlNet-TurboCell-TxRate TxRate-519k 519\r
-VALUE KarlNet-TurboCell-TxRate TxRate-520k 520\r
-VALUE KarlNet-TurboCell-TxRate TxRate-521k 521\r
-VALUE KarlNet-TurboCell-TxRate TxRate-522k 522\r
-VALUE KarlNet-TurboCell-TxRate TxRate-523k 523\r
-VALUE KarlNet-TurboCell-TxRate TxRate-524k 524\r
-VALUE KarlNet-TurboCell-TxRate TxRate-525k 525\r
-VALUE KarlNet-TurboCell-TxRate TxRate-526k 526\r
-VALUE KarlNet-TurboCell-TxRate TxRate-527k 527\r
-VALUE KarlNet-TurboCell-TxRate TxRate-528k 528\r
-VALUE KarlNet-TurboCell-TxRate TxRate-529k 529\r
-VALUE KarlNet-TurboCell-TxRate TxRate-530k 530\r
-VALUE KarlNet-TurboCell-TxRate TxRate-531k 531\r
-VALUE KarlNet-TurboCell-TxRate TxRate-532k 532\r
-VALUE KarlNet-TurboCell-TxRate TxRate-533k 533\r
-VALUE KarlNet-TurboCell-TxRate TxRate-534k 534\r
-VALUE KarlNet-TurboCell-TxRate TxRate-535k 535\r
-VALUE KarlNet-TurboCell-TxRate TxRate-536k 536\r
-VALUE KarlNet-TurboCell-TxRate TxRate-537k 537\r
-VALUE KarlNet-TurboCell-TxRate TxRate-538k 538\r
-VALUE KarlNet-TurboCell-TxRate TxRate-539k 539\r
-VALUE KarlNet-TurboCell-TxRate TxRate-540k 540\r
-VALUE KarlNet-TurboCell-TxRate TxRate-541k 541\r
-VALUE KarlNet-TurboCell-TxRate TxRate-542k 542\r
-VALUE KarlNet-TurboCell-TxRate TxRate-543k 543\r
-VALUE KarlNet-TurboCell-TxRate TxRate-544k 544\r
-VALUE KarlNet-TurboCell-TxRate TxRate-545k 545\r
-VALUE KarlNet-TurboCell-TxRate TxRate-546k 546\r
-VALUE KarlNet-TurboCell-TxRate TxRate-547k 547\r
-VALUE KarlNet-TurboCell-TxRate TxRate-548k 548\r
-VALUE KarlNet-TurboCell-TxRate TxRate-549k 549\r
-VALUE KarlNet-TurboCell-TxRate TxRate-550k 550\r
-VALUE KarlNet-TurboCell-TxRate TxRate-551k 551\r
-VALUE KarlNet-TurboCell-TxRate TxRate-552k 552\r
-VALUE KarlNet-TurboCell-TxRate TxRate-553k 553\r
-VALUE KarlNet-TurboCell-TxRate TxRate-554k 554\r
-VALUE KarlNet-TurboCell-TxRate TxRate-555k 555\r
-VALUE KarlNet-TurboCell-TxRate TxRate-556k 556\r
-VALUE KarlNet-TurboCell-TxRate TxRate-557k 557\r
-VALUE KarlNet-TurboCell-TxRate TxRate-558k 558\r
-VALUE KarlNet-TurboCell-TxRate TxRate-559k 559\r
-VALUE KarlNet-TurboCell-TxRate TxRate-560k 560\r
-VALUE KarlNet-TurboCell-TxRate TxRate-561k 561\r
-VALUE KarlNet-TurboCell-TxRate TxRate-562k 562\r
-VALUE KarlNet-TurboCell-TxRate TxRate-563k 563\r
-VALUE KarlNet-TurboCell-TxRate TxRate-564k 564\r
-VALUE KarlNet-TurboCell-TxRate TxRate-565k 565\r
-VALUE KarlNet-TurboCell-TxRate TxRate-566k 566\r
-VALUE KarlNet-TurboCell-TxRate TxRate-567k 567\r
-VALUE KarlNet-TurboCell-TxRate TxRate-568k 568\r
-VALUE KarlNet-TurboCell-TxRate TxRate-569k 569\r
-VALUE KarlNet-TurboCell-TxRate TxRate-570k 570\r
-VALUE KarlNet-TurboCell-TxRate TxRate-571k 571\r
-VALUE KarlNet-TurboCell-TxRate TxRate-572k 572\r
-VALUE KarlNet-TurboCell-TxRate TxRate-573k 573\r
-VALUE KarlNet-TurboCell-TxRate TxRate-574k 574\r
-VALUE KarlNet-TurboCell-TxRate TxRate-575k 575\r
-VALUE KarlNet-TurboCell-TxRate TxRate-576k 576\r
-VALUE KarlNet-TurboCell-TxRate TxRate-577k 577\r
-VALUE KarlNet-TurboCell-TxRate TxRate-578k 578\r
-VALUE KarlNet-TurboCell-TxRate TxRate-579k 579\r
-VALUE KarlNet-TurboCell-TxRate TxRate-580k 580\r
-VALUE KarlNet-TurboCell-TxRate TxRate-581k 581\r
-VALUE KarlNet-TurboCell-TxRate TxRate-582k 582\r
-VALUE KarlNet-TurboCell-TxRate TxRate-583k 583\r
-VALUE KarlNet-TurboCell-TxRate TxRate-584k 584\r
-VALUE KarlNet-TurboCell-TxRate TxRate-585k 585\r
-VALUE KarlNet-TurboCell-TxRate TxRate-586k 586\r
-VALUE KarlNet-TurboCell-TxRate TxRate-587k 587\r
-VALUE KarlNet-TurboCell-TxRate TxRate-588k 588\r
-VALUE KarlNet-TurboCell-TxRate TxRate-589k 589\r
-VALUE KarlNet-TurboCell-TxRate TxRate-590k 590\r
-VALUE KarlNet-TurboCell-TxRate TxRate-591k 591\r
-VALUE KarlNet-TurboCell-TxRate TxRate-592k 592\r
-VALUE KarlNet-TurboCell-TxRate TxRate-593k 593\r
-VALUE KarlNet-TurboCell-TxRate TxRate-594k 594\r
-VALUE KarlNet-TurboCell-TxRate TxRate-595k 595\r
-VALUE KarlNet-TurboCell-TxRate TxRate-596k 596\r
-VALUE KarlNet-TurboCell-TxRate TxRate-597k 597\r
-VALUE KarlNet-TurboCell-TxRate TxRate-598k 598\r
-VALUE KarlNet-TurboCell-TxRate TxRate-599k 599\r
-VALUE KarlNet-TurboCell-TxRate TxRate-600k 600\r
-VALUE KarlNet-TurboCell-TxRate TxRate-601k 601\r
-VALUE KarlNet-TurboCell-TxRate TxRate-602k 602\r
-VALUE KarlNet-TurboCell-TxRate TxRate-603k 603\r
-VALUE KarlNet-TurboCell-TxRate TxRate-604k 604\r
-VALUE KarlNet-TurboCell-TxRate TxRate-605k 605\r
-VALUE KarlNet-TurboCell-TxRate TxRate-606k 606\r
-VALUE KarlNet-TurboCell-TxRate TxRate-607k 607\r
-VALUE KarlNet-TurboCell-TxRate TxRate-608k 608\r
-VALUE KarlNet-TurboCell-TxRate TxRate-609k 609\r
-VALUE KarlNet-TurboCell-TxRate TxRate-610k 610\r
-VALUE KarlNet-TurboCell-TxRate TxRate-611k 611\r
-VALUE KarlNet-TurboCell-TxRate TxRate-612k 612\r
-VALUE KarlNet-TurboCell-TxRate TxRate-613k 613\r
-VALUE KarlNet-TurboCell-TxRate TxRate-614k 614\r
-VALUE KarlNet-TurboCell-TxRate TxRate-615k 615\r
-VALUE KarlNet-TurboCell-TxRate TxRate-616k 616\r
-VALUE KarlNet-TurboCell-TxRate TxRate-617k 617\r
-VALUE KarlNet-TurboCell-TxRate TxRate-618k 618\r
-VALUE KarlNet-TurboCell-TxRate TxRate-619k 619\r
-VALUE KarlNet-TurboCell-TxRate TxRate-620k 620\r
-VALUE KarlNet-TurboCell-TxRate TxRate-621k 621\r
-VALUE KarlNet-TurboCell-TxRate TxRate-622k 622\r
-VALUE KarlNet-TurboCell-TxRate TxRate-623k 623\r
-VALUE KarlNet-TurboCell-TxRate TxRate-624k 624\r
-VALUE KarlNet-TurboCell-TxRate TxRate-625k 625\r
-VALUE KarlNet-TurboCell-TxRate TxRate-626k 626\r
-VALUE KarlNet-TurboCell-TxRate TxRate-627k 627\r
-VALUE KarlNet-TurboCell-TxRate TxRate-628k 628\r
-VALUE KarlNet-TurboCell-TxRate TxRate-629k 629\r
-VALUE KarlNet-TurboCell-TxRate TxRate-630k 630\r
-VALUE KarlNet-TurboCell-TxRate TxRate-631k 631\r
-VALUE KarlNet-TurboCell-TxRate TxRate-632k 632\r
-VALUE KarlNet-TurboCell-TxRate TxRate-633k 633\r
-VALUE KarlNet-TurboCell-TxRate TxRate-634k 634\r
-VALUE KarlNet-TurboCell-TxRate TxRate-635k 635\r
-VALUE KarlNet-TurboCell-TxRate TxRate-636k 636\r
-VALUE KarlNet-TurboCell-TxRate TxRate-637k 637\r
-VALUE KarlNet-TurboCell-TxRate TxRate-638k 638\r
-VALUE KarlNet-TurboCell-TxRate TxRate-639k 639\r
-VALUE KarlNet-TurboCell-TxRate TxRate-640k 640\r
-VALUE KarlNet-TurboCell-TxRate TxRate-641k 641\r
-VALUE KarlNet-TurboCell-TxRate TxRate-642k 642\r
-VALUE KarlNet-TurboCell-TxRate TxRate-643k 643\r
-VALUE KarlNet-TurboCell-TxRate TxRate-644k 644\r
-VALUE KarlNet-TurboCell-TxRate TxRate-645k 645\r
-VALUE KarlNet-TurboCell-TxRate TxRate-646k 646\r
-VALUE KarlNet-TurboCell-TxRate TxRate-647k 647\r
-VALUE KarlNet-TurboCell-TxRate TxRate-648k 648\r
-VALUE KarlNet-TurboCell-TxRate TxRate-649k 649\r
-VALUE KarlNet-TurboCell-TxRate TxRate-650k 650\r
-VALUE KarlNet-TurboCell-TxRate TxRate-651k 651\r
-VALUE KarlNet-TurboCell-TxRate TxRate-652k 652\r
-VALUE KarlNet-TurboCell-TxRate TxRate-653k 653\r
-VALUE KarlNet-TurboCell-TxRate TxRate-654k 654\r
-VALUE KarlNet-TurboCell-TxRate TxRate-655k 655\r
-VALUE KarlNet-TurboCell-TxRate TxRate-656k 656\r
-VALUE KarlNet-TurboCell-TxRate TxRate-657k 657\r
-VALUE KarlNet-TurboCell-TxRate TxRate-658k 658\r
-VALUE KarlNet-TurboCell-TxRate TxRate-659k 659\r
-VALUE KarlNet-TurboCell-TxRate TxRate-660k 660\r
-VALUE KarlNet-TurboCell-TxRate TxRate-661k 661\r
-VALUE KarlNet-TurboCell-TxRate TxRate-662k 662\r
-VALUE KarlNet-TurboCell-TxRate TxRate-663k 663\r
-VALUE KarlNet-TurboCell-TxRate TxRate-664k 664\r
-VALUE KarlNet-TurboCell-TxRate TxRate-665k 665\r
-VALUE KarlNet-TurboCell-TxRate TxRate-666k 666\r
-VALUE KarlNet-TurboCell-TxRate TxRate-667k 667\r
-VALUE KarlNet-TurboCell-TxRate TxRate-668k 668\r
-VALUE KarlNet-TurboCell-TxRate TxRate-669k 669\r
-VALUE KarlNet-TurboCell-TxRate TxRate-670k 670\r
-VALUE KarlNet-TurboCell-TxRate TxRate-671k 671\r
-VALUE KarlNet-TurboCell-TxRate TxRate-672k 672\r
-VALUE KarlNet-TurboCell-TxRate TxRate-673k 673\r
-VALUE KarlNet-TurboCell-TxRate TxRate-674k 674\r
-VALUE KarlNet-TurboCell-TxRate TxRate-675k 675\r
-VALUE KarlNet-TurboCell-TxRate TxRate-676k 676\r
-VALUE KarlNet-TurboCell-TxRate TxRate-677k 677\r
-VALUE KarlNet-TurboCell-TxRate TxRate-678k 678\r
-VALUE KarlNet-TurboCell-TxRate TxRate-679k 679\r
-VALUE KarlNet-TurboCell-TxRate TxRate-680k 680\r
-VALUE KarlNet-TurboCell-TxRate TxRate-681k 681\r
-VALUE KarlNet-TurboCell-TxRate TxRate-682k 682\r
-VALUE KarlNet-TurboCell-TxRate TxRate-683k 683\r
-VALUE KarlNet-TurboCell-TxRate TxRate-684k 684\r
-VALUE KarlNet-TurboCell-TxRate TxRate-685k 685\r
-VALUE KarlNet-TurboCell-TxRate TxRate-686k 686\r
-VALUE KarlNet-TurboCell-TxRate TxRate-687k 687\r
-VALUE KarlNet-TurboCell-TxRate TxRate-688k 688\r
-VALUE KarlNet-TurboCell-TxRate TxRate-689k 689\r
-VALUE KarlNet-TurboCell-TxRate TxRate-690k 690\r
-VALUE KarlNet-TurboCell-TxRate TxRate-691k 691\r
-VALUE KarlNet-TurboCell-TxRate TxRate-692k 692\r
-VALUE KarlNet-TurboCell-TxRate TxRate-693k 693\r
-VALUE KarlNet-TurboCell-TxRate TxRate-694k 694\r
-VALUE KarlNet-TurboCell-TxRate TxRate-695k 695\r
-VALUE KarlNet-TurboCell-TxRate TxRate-696k 696\r
-VALUE KarlNet-TurboCell-TxRate TxRate-697k 697\r
-VALUE KarlNet-TurboCell-TxRate TxRate-698k 698\r
-VALUE KarlNet-TurboCell-TxRate TxRate-699k 699\r
-VALUE KarlNet-TurboCell-TxRate TxRate-700k 700\r
-VALUE KarlNet-TurboCell-TxRate TxRate-701k 701\r
-VALUE KarlNet-TurboCell-TxRate TxRate-702k 702\r
-VALUE KarlNet-TurboCell-TxRate TxRate-703k 703\r
-VALUE KarlNet-TurboCell-TxRate TxRate-704k 704\r
-VALUE KarlNet-TurboCell-TxRate TxRate-705k 705\r
-VALUE KarlNet-TurboCell-TxRate TxRate-706k 706\r
-VALUE KarlNet-TurboCell-TxRate TxRate-707k 707\r
-VALUE KarlNet-TurboCell-TxRate TxRate-708k 708\r
-VALUE KarlNet-TurboCell-TxRate TxRate-709k 709\r
-VALUE KarlNet-TurboCell-TxRate TxRate-710k 710\r
-VALUE KarlNet-TurboCell-TxRate TxRate-711k 711\r
-VALUE KarlNet-TurboCell-TxRate TxRate-712k 712\r
-VALUE KarlNet-TurboCell-TxRate TxRate-713k 713\r
-VALUE KarlNet-TurboCell-TxRate TxRate-714k 714\r
-VALUE KarlNet-TurboCell-TxRate TxRate-715k 715\r
-VALUE KarlNet-TurboCell-TxRate TxRate-716k 716\r
-VALUE KarlNet-TurboCell-TxRate TxRate-717k 717\r
-VALUE KarlNet-TurboCell-TxRate TxRate-718k 718\r
-VALUE KarlNet-TurboCell-TxRate TxRate-719k 719\r
-VALUE KarlNet-TurboCell-TxRate TxRate-720k 720\r
-VALUE KarlNet-TurboCell-TxRate TxRate-721k 721\r
-VALUE KarlNet-TurboCell-TxRate TxRate-722k 722\r
-VALUE KarlNet-TurboCell-TxRate TxRate-723k 723\r
-VALUE KarlNet-TurboCell-TxRate TxRate-724k 724\r
-VALUE KarlNet-TurboCell-TxRate TxRate-725k 725\r
-VALUE KarlNet-TurboCell-TxRate TxRate-726k 726\r
-VALUE KarlNet-TurboCell-TxRate TxRate-727k 727\r
-VALUE KarlNet-TurboCell-TxRate TxRate-728k 728\r
-VALUE KarlNet-TurboCell-TxRate TxRate-729k 729\r
-VALUE KarlNet-TurboCell-TxRate TxRate-730k 730\r
-VALUE KarlNet-TurboCell-TxRate TxRate-731k 731\r
-VALUE KarlNet-TurboCell-TxRate TxRate-732k 732\r
-VALUE KarlNet-TurboCell-TxRate TxRate-733k 733\r
-VALUE KarlNet-TurboCell-TxRate TxRate-734k 734\r
-VALUE KarlNet-TurboCell-TxRate TxRate-735k 735\r
-VALUE KarlNet-TurboCell-TxRate TxRate-736k 736\r
-VALUE KarlNet-TurboCell-TxRate TxRate-737k 737\r
-VALUE KarlNet-TurboCell-TxRate TxRate-738k 738\r
-VALUE KarlNet-TurboCell-TxRate TxRate-739k 739\r
-VALUE KarlNet-TurboCell-TxRate TxRate-740k 740\r
-VALUE KarlNet-TurboCell-TxRate TxRate-741k 741\r
-VALUE KarlNet-TurboCell-TxRate TxRate-742k 742\r
-VALUE KarlNet-TurboCell-TxRate TxRate-743k 743\r
-VALUE KarlNet-TurboCell-TxRate TxRate-744k 744\r
-VALUE KarlNet-TurboCell-TxRate TxRate-745k 745\r
-VALUE KarlNet-TurboCell-TxRate TxRate-746k 746\r
-VALUE KarlNet-TurboCell-TxRate TxRate-747k 747\r
-VALUE KarlNet-TurboCell-TxRate TxRate-748k 748\r
-VALUE KarlNet-TurboCell-TxRate TxRate-749k 749\r
-VALUE KarlNet-TurboCell-TxRate TxRate-750k 750\r
-VALUE KarlNet-TurboCell-TxRate TxRate-751k 751\r
-VALUE KarlNet-TurboCell-TxRate TxRate-752k 752\r
-VALUE KarlNet-TurboCell-TxRate TxRate-753k 753\r
-VALUE KarlNet-TurboCell-TxRate TxRate-754k 754\r
-VALUE KarlNet-TurboCell-TxRate TxRate-755k 755\r
-VALUE KarlNet-TurboCell-TxRate TxRate-756k 756\r
-VALUE KarlNet-TurboCell-TxRate TxRate-757k 757\r
-VALUE KarlNet-TurboCell-TxRate TxRate-758k 758\r
-VALUE KarlNet-TurboCell-TxRate TxRate-759k 759\r
-VALUE KarlNet-TurboCell-TxRate TxRate-760k 760\r
-VALUE KarlNet-TurboCell-TxRate TxRate-761k 761\r
-VALUE KarlNet-TurboCell-TxRate TxRate-762k 762\r
-VALUE KarlNet-TurboCell-TxRate TxRate-763k 763\r
-VALUE KarlNet-TurboCell-TxRate TxRate-764k 764\r
-VALUE KarlNet-TurboCell-TxRate TxRate-765k 765\r
-VALUE KarlNet-TurboCell-TxRate TxRate-766k 766\r
-VALUE KarlNet-TurboCell-TxRate TxRate-767k 767\r
-VALUE KarlNet-TurboCell-TxRate TxRate-768k 768\r
-VALUE KarlNet-TurboCell-TxRate TxRate-769k 769\r
-VALUE KarlNet-TurboCell-TxRate TxRate-770k 770\r
-VALUE KarlNet-TurboCell-TxRate TxRate-771k 771\r
-VALUE KarlNet-TurboCell-TxRate TxRate-772k 772\r
-VALUE KarlNet-TurboCell-TxRate TxRate-773k 773\r
-VALUE KarlNet-TurboCell-TxRate TxRate-774k 774\r
-VALUE KarlNet-TurboCell-TxRate TxRate-775k 775\r
-VALUE KarlNet-TurboCell-TxRate TxRate-776k 776\r
-VALUE KarlNet-TurboCell-TxRate TxRate-777k 777\r
-VALUE KarlNet-TurboCell-TxRate TxRate-778k 778\r
-VALUE KarlNet-TurboCell-TxRate TxRate-779k 779\r
-VALUE KarlNet-TurboCell-TxRate TxRate-780k 780\r
-VALUE KarlNet-TurboCell-TxRate TxRate-781k 781\r
-VALUE KarlNet-TurboCell-TxRate TxRate-782k 782\r
-VALUE KarlNet-TurboCell-TxRate TxRate-783k 783\r
-VALUE KarlNet-TurboCell-TxRate TxRate-784k 784\r
-VALUE KarlNet-TurboCell-TxRate TxRate-785k 785\r
-VALUE KarlNet-TurboCell-TxRate TxRate-786k 786\r
-VALUE KarlNet-TurboCell-TxRate TxRate-787k 787\r
-VALUE KarlNet-TurboCell-TxRate TxRate-788k 788\r
-VALUE KarlNet-TurboCell-TxRate TxRate-789k 789\r
-VALUE KarlNet-TurboCell-TxRate TxRate-790k 790\r
-VALUE KarlNet-TurboCell-TxRate TxRate-791k 791\r
-VALUE KarlNet-TurboCell-TxRate TxRate-792k 792\r
-VALUE KarlNet-TurboCell-TxRate TxRate-793k 793\r
-VALUE KarlNet-TurboCell-TxRate TxRate-794k 794\r
-VALUE KarlNet-TurboCell-TxRate TxRate-795k 795\r
-VALUE KarlNet-TurboCell-TxRate TxRate-796k 796\r
-VALUE KarlNet-TurboCell-TxRate TxRate-797k 797\r
-VALUE KarlNet-TurboCell-TxRate TxRate-798k 798\r
-VALUE KarlNet-TurboCell-TxRate TxRate-799k 799\r
-VALUE KarlNet-TurboCell-TxRate TxRate-800k 800\r
-VALUE KarlNet-TurboCell-TxRate TxRate-801k 801\r
-VALUE KarlNet-TurboCell-TxRate TxRate-802k 802\r
-VALUE KarlNet-TurboCell-TxRate TxRate-803k 803\r
-VALUE KarlNet-TurboCell-TxRate TxRate-804k 804\r
-VALUE KarlNet-TurboCell-TxRate TxRate-805k 805\r
-VALUE KarlNet-TurboCell-TxRate TxRate-806k 806\r
-VALUE KarlNet-TurboCell-TxRate TxRate-807k 807\r
-VALUE KarlNet-TurboCell-TxRate TxRate-808k 808\r
-VALUE KarlNet-TurboCell-TxRate TxRate-809k 809\r
-VALUE KarlNet-TurboCell-TxRate TxRate-810k 810\r
-VALUE KarlNet-TurboCell-TxRate TxRate-811k 811\r
-VALUE KarlNet-TurboCell-TxRate TxRate-812k 812\r
-VALUE KarlNet-TurboCell-TxRate TxRate-813k 813\r
-VALUE KarlNet-TurboCell-TxRate TxRate-814k 814\r
-VALUE KarlNet-TurboCell-TxRate TxRate-815k 815\r
-VALUE KarlNet-TurboCell-TxRate TxRate-816k 816\r
-VALUE KarlNet-TurboCell-TxRate TxRate-817k 817\r
-VALUE KarlNet-TurboCell-TxRate TxRate-818k 818\r
-VALUE KarlNet-TurboCell-TxRate TxRate-819k 819\r
-VALUE KarlNet-TurboCell-TxRate TxRate-820k 820\r
-VALUE KarlNet-TurboCell-TxRate TxRate-821k 821\r
-VALUE KarlNet-TurboCell-TxRate TxRate-822k 822\r
-VALUE KarlNet-TurboCell-TxRate TxRate-823k 823\r
-VALUE KarlNet-TurboCell-TxRate TxRate-824k 824\r
-VALUE KarlNet-TurboCell-TxRate TxRate-825k 825\r
-VALUE KarlNet-TurboCell-TxRate TxRate-826k 826\r
-VALUE KarlNet-TurboCell-TxRate TxRate-827k 827\r
-VALUE KarlNet-TurboCell-TxRate TxRate-828k 828\r
-VALUE KarlNet-TurboCell-TxRate TxRate-829k 829\r
-VALUE KarlNet-TurboCell-TxRate TxRate-830k 830\r
-VALUE KarlNet-TurboCell-TxRate TxRate-831k 831\r
-VALUE KarlNet-TurboCell-TxRate TxRate-832k 832\r
-VALUE KarlNet-TurboCell-TxRate TxRate-833k 833\r
-VALUE KarlNet-TurboCell-TxRate TxRate-834k 834\r
-VALUE KarlNet-TurboCell-TxRate TxRate-835k 835\r
-VALUE KarlNet-TurboCell-TxRate TxRate-836k 836\r
-VALUE KarlNet-TurboCell-TxRate TxRate-837k 837\r
-VALUE KarlNet-TurboCell-TxRate TxRate-838k 838\r
-VALUE KarlNet-TurboCell-TxRate TxRate-839k 839\r
-VALUE KarlNet-TurboCell-TxRate TxRate-840k 840\r
-VALUE KarlNet-TurboCell-TxRate TxRate-841k 841\r
-VALUE KarlNet-TurboCell-TxRate TxRate-842k 842\r
-VALUE KarlNet-TurboCell-TxRate TxRate-843k 843\r
-VALUE KarlNet-TurboCell-TxRate TxRate-844k 844\r
-VALUE KarlNet-TurboCell-TxRate TxRate-845k 845\r
-VALUE KarlNet-TurboCell-TxRate TxRate-846k 846\r
-VALUE KarlNet-TurboCell-TxRate TxRate-847k 847\r
-VALUE KarlNet-TurboCell-TxRate TxRate-848k 848\r
-VALUE KarlNet-TurboCell-TxRate TxRate-849k 849\r
-VALUE KarlNet-TurboCell-TxRate TxRate-850k 850\r
-VALUE KarlNet-TurboCell-TxRate TxRate-851k 851\r
-VALUE KarlNet-TurboCell-TxRate TxRate-852k 852\r
-VALUE KarlNet-TurboCell-TxRate TxRate-853k 853\r
-VALUE KarlNet-TurboCell-TxRate TxRate-854k 854\r
-VALUE KarlNet-TurboCell-TxRate TxRate-855k 855\r
-VALUE KarlNet-TurboCell-TxRate TxRate-856k 856\r
-VALUE KarlNet-TurboCell-TxRate TxRate-857k 857\r
-VALUE KarlNet-TurboCell-TxRate TxRate-858k 858\r
-VALUE KarlNet-TurboCell-TxRate TxRate-859k 859\r
-VALUE KarlNet-TurboCell-TxRate TxRate-860k 860\r
-VALUE KarlNet-TurboCell-TxRate TxRate-861k 861\r
-VALUE KarlNet-TurboCell-TxRate TxRate-862k 862\r
-VALUE KarlNet-TurboCell-TxRate TxRate-863k 863\r
-VALUE KarlNet-TurboCell-TxRate TxRate-864k 864\r
-VALUE KarlNet-TurboCell-TxRate TxRate-865k 865\r
-VALUE KarlNet-TurboCell-TxRate TxRate-866k 866\r
-VALUE KarlNet-TurboCell-TxRate TxRate-867k 867\r
-VALUE KarlNet-TurboCell-TxRate TxRate-868k 868\r
-VALUE KarlNet-TurboCell-TxRate TxRate-869k 869\r
-VALUE KarlNet-TurboCell-TxRate TxRate-870k 870\r
-VALUE KarlNet-TurboCell-TxRate TxRate-871k 871\r
-VALUE KarlNet-TurboCell-TxRate TxRate-872k 872\r
-VALUE KarlNet-TurboCell-TxRate TxRate-873k 873\r
-VALUE KarlNet-TurboCell-TxRate TxRate-874k 874\r
-VALUE KarlNet-TurboCell-TxRate TxRate-875k 875\r
-VALUE KarlNet-TurboCell-TxRate TxRate-876k 876\r
-VALUE KarlNet-TurboCell-TxRate TxRate-877k 877\r
-VALUE KarlNet-TurboCell-TxRate TxRate-878k 878\r
-VALUE KarlNet-TurboCell-TxRate TxRate-879k 879\r
-VALUE KarlNet-TurboCell-TxRate TxRate-880k 880\r
-VALUE KarlNet-TurboCell-TxRate TxRate-881k 881\r
-VALUE KarlNet-TurboCell-TxRate TxRate-882k 882\r
-VALUE KarlNet-TurboCell-TxRate TxRate-883k 883\r
-VALUE KarlNet-TurboCell-TxRate TxRate-884k 884\r
-VALUE KarlNet-TurboCell-TxRate TxRate-885k 885\r
-VALUE KarlNet-TurboCell-TxRate TxRate-886k 886\r
-VALUE KarlNet-TurboCell-TxRate TxRate-887k 887\r
-VALUE KarlNet-TurboCell-TxRate TxRate-888k 888\r
-VALUE KarlNet-TurboCell-TxRate TxRate-889k 889\r
-VALUE KarlNet-TurboCell-TxRate TxRate-890k 890\r
-VALUE KarlNet-TurboCell-TxRate TxRate-891k 891\r
-VALUE KarlNet-TurboCell-TxRate TxRate-892k 892\r
-VALUE KarlNet-TurboCell-TxRate TxRate-893k 893\r
-VALUE KarlNet-TurboCell-TxRate TxRate-894k 894\r
-VALUE KarlNet-TurboCell-TxRate TxRate-895k 895\r
-VALUE KarlNet-TurboCell-TxRate TxRate-896k 896\r
-VALUE KarlNet-TurboCell-TxRate TxRate-897k 897\r
-VALUE KarlNet-TurboCell-TxRate TxRate-898k 898\r
-VALUE KarlNet-TurboCell-TxRate TxRate-899k 899\r
-VALUE KarlNet-TurboCell-TxRate TxRate-900k 900\r
-VALUE KarlNet-TurboCell-TxRate TxRate-901k 901\r
-VALUE KarlNet-TurboCell-TxRate TxRate-902k 902\r
-VALUE KarlNet-TurboCell-TxRate TxRate-903k 903\r
-VALUE KarlNet-TurboCell-TxRate TxRate-904k 904\r
-VALUE KarlNet-TurboCell-TxRate TxRate-905k 905\r
-VALUE KarlNet-TurboCell-TxRate TxRate-906k 906\r
-VALUE KarlNet-TurboCell-TxRate TxRate-907k 907\r
-VALUE KarlNet-TurboCell-TxRate TxRate-908k 908\r
-VALUE KarlNet-TurboCell-TxRate TxRate-909k 909\r
-VALUE KarlNet-TurboCell-TxRate TxRate-910k 910\r
-VALUE KarlNet-TurboCell-TxRate TxRate-911k 911\r
-VALUE KarlNet-TurboCell-TxRate TxRate-912k 912\r
-VALUE KarlNet-TurboCell-TxRate TxRate-913k 913\r
-VALUE KarlNet-TurboCell-TxRate TxRate-914k 914\r
-VALUE KarlNet-TurboCell-TxRate TxRate-915k 915\r
-VALUE KarlNet-TurboCell-TxRate TxRate-916k 916\r
-VALUE KarlNet-TurboCell-TxRate TxRate-917k 917\r
-VALUE KarlNet-TurboCell-TxRate TxRate-918k 918\r
-VALUE KarlNet-TurboCell-TxRate TxRate-919k 919\r
-VALUE KarlNet-TurboCell-TxRate TxRate-920k 920\r
-VALUE KarlNet-TurboCell-TxRate TxRate-921k 921\r
-VALUE KarlNet-TurboCell-TxRate TxRate-922k 922\r
-VALUE KarlNet-TurboCell-TxRate TxRate-923k 923\r
-VALUE KarlNet-TurboCell-TxRate TxRate-924k 924\r
-VALUE KarlNet-TurboCell-TxRate TxRate-925k 925\r
-VALUE KarlNet-TurboCell-TxRate TxRate-926k 926\r
-VALUE KarlNet-TurboCell-TxRate TxRate-927k 927\r
-VALUE KarlNet-TurboCell-TxRate TxRate-928k 928\r
-VALUE KarlNet-TurboCell-TxRate TxRate-929k 929\r
-VALUE KarlNet-TurboCell-TxRate TxRate-930k 930\r
-VALUE KarlNet-TurboCell-TxRate TxRate-931k 931\r
-VALUE KarlNet-TurboCell-TxRate TxRate-932k 932\r
-VALUE KarlNet-TurboCell-TxRate TxRate-933k 933\r
-VALUE KarlNet-TurboCell-TxRate TxRate-934k 934\r
-VALUE KarlNet-TurboCell-TxRate TxRate-935k 935\r
-VALUE KarlNet-TurboCell-TxRate TxRate-936k 936\r
-VALUE KarlNet-TurboCell-TxRate TxRate-937k 937\r
-VALUE KarlNet-TurboCell-TxRate TxRate-938k 938\r
-VALUE KarlNet-TurboCell-TxRate TxRate-939k 939\r
-VALUE KarlNet-TurboCell-TxRate TxRate-940k 940\r
-VALUE KarlNet-TurboCell-TxRate TxRate-941k 941\r
-VALUE KarlNet-TurboCell-TxRate TxRate-942k 942\r
-VALUE KarlNet-TurboCell-TxRate TxRate-943k 943\r
-VALUE KarlNet-TurboCell-TxRate TxRate-944k 944\r
-VALUE KarlNet-TurboCell-TxRate TxRate-945k 945\r
-VALUE KarlNet-TurboCell-TxRate TxRate-946k 946\r
-VALUE KarlNet-TurboCell-TxRate TxRate-947k 947\r
-VALUE KarlNet-TurboCell-TxRate TxRate-948k 948\r
-VALUE KarlNet-TurboCell-TxRate TxRate-949k 949\r
-VALUE KarlNet-TurboCell-TxRate TxRate-950k 950\r
-VALUE KarlNet-TurboCell-TxRate TxRate-951k 951\r
-VALUE KarlNet-TurboCell-TxRate TxRate-952k 952\r
-VALUE KarlNet-TurboCell-TxRate TxRate-953k 953\r
-VALUE KarlNet-TurboCell-TxRate TxRate-954k 954\r
-VALUE KarlNet-TurboCell-TxRate TxRate-955k 955\r
-VALUE KarlNet-TurboCell-TxRate TxRate-956k 956\r
-VALUE KarlNet-TurboCell-TxRate TxRate-957k 957\r
-VALUE KarlNet-TurboCell-TxRate TxRate-958k 958\r
-VALUE KarlNet-TurboCell-TxRate TxRate-959k 959\r
-VALUE KarlNet-TurboCell-TxRate TxRate-960k 960\r
-VALUE KarlNet-TurboCell-TxRate TxRate-961k 961\r
-VALUE KarlNet-TurboCell-TxRate TxRate-962k 962\r
-VALUE KarlNet-TurboCell-TxRate TxRate-963k 963\r
-VALUE KarlNet-TurboCell-TxRate TxRate-964k 964\r
-VALUE KarlNet-TurboCell-TxRate TxRate-965k 965\r
-VALUE KarlNet-TurboCell-TxRate TxRate-966k 966\r
-VALUE KarlNet-TurboCell-TxRate TxRate-967k 967\r
-VALUE KarlNet-TurboCell-TxRate TxRate-968k 968\r
-VALUE KarlNet-TurboCell-TxRate TxRate-969k 969\r
-VALUE KarlNet-TurboCell-TxRate TxRate-970k 970\r
-VALUE KarlNet-TurboCell-TxRate TxRate-971k 971\r
-VALUE KarlNet-TurboCell-TxRate TxRate-972k 972\r
-VALUE KarlNet-TurboCell-TxRate TxRate-973k 973\r
-VALUE KarlNet-TurboCell-TxRate TxRate-974k 974\r
-VALUE KarlNet-TurboCell-TxRate TxRate-975k 975\r
-VALUE KarlNet-TurboCell-TxRate TxRate-976k 976\r
-VALUE KarlNet-TurboCell-TxRate TxRate-977k 977\r
-VALUE KarlNet-TurboCell-TxRate TxRate-978k 978\r
-VALUE KarlNet-TurboCell-TxRate TxRate-979k 979\r
-VALUE KarlNet-TurboCell-TxRate TxRate-980k 980\r
-VALUE KarlNet-TurboCell-TxRate TxRate-981k 981\r
-VALUE KarlNet-TurboCell-TxRate TxRate-982k 982\r
-VALUE KarlNet-TurboCell-TxRate TxRate-983k 983\r
-VALUE KarlNet-TurboCell-TxRate TxRate-984k 984\r
-VALUE KarlNet-TurboCell-TxRate TxRate-985k 985\r
-VALUE KarlNet-TurboCell-TxRate TxRate-986k 986\r
-VALUE KarlNet-TurboCell-TxRate TxRate-987k 987\r
-VALUE KarlNet-TurboCell-TxRate TxRate-988k 988\r
-VALUE KarlNet-TurboCell-TxRate TxRate-989k 989\r
-VALUE KarlNet-TurboCell-TxRate TxRate-990k 990\r
-VALUE KarlNet-TurboCell-TxRate TxRate-991k 991\r
-VALUE KarlNet-TurboCell-TxRate TxRate-992k 992\r
-VALUE KarlNet-TurboCell-TxRate TxRate-993k 993\r
-VALUE KarlNet-TurboCell-TxRate TxRate-994k 994\r
-VALUE KarlNet-TurboCell-TxRate TxRate-995k 995\r
-VALUE KarlNet-TurboCell-TxRate TxRate-996k 996\r
-VALUE KarlNet-TurboCell-TxRate TxRate-997k 997\r
-VALUE KarlNet-TurboCell-TxRate TxRate-998k 998\r
-VALUE KarlNet-TurboCell-TxRate TxRate-999k 999\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1000k 1000\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1001k 1001\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1002k 1002\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1003k 1003\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1004k 1004\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1005k 1005\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1006k 1006\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1007k 1007\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1008k 1008\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1009k 1009\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1010k 1010\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1011k 1011\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1012k 1012\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1013k 1013\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1014k 1014\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1015k 1015\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1016k 1016\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1017k 1017\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1018k 1018\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1019k 1019\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1020k 1020\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1021k 1021\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1022k 1022\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1023k 1023\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1024k 1024\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1152k 1025\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1280k 1026\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1408k 1027\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1536k 1028\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1664k 1029\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1792k 1030\r
-VALUE KarlNet-TurboCell-TxRate TxRate-1920k 1031\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2048k 1032\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2176k 1033\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2304k 1034\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2432k 1035\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2560k 1036\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2688k 1037\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2816k 1038\r
-VALUE KarlNet-TurboCell-TxRate TxRate-2944k 1039\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3072k 1040\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3200k 1041\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3328k 1042\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3456k 1043\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3584k 1044\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3712k 1045\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3840k 1046\r
-VALUE KarlNet-TurboCell-TxRate TxRate-3968k 1047\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4096k 1048\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4224k 1049\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4352k 1050\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4480k 1051\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4608k 1052\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4736k 1053\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4864k 1054\r
-VALUE KarlNet-TurboCell-TxRate TxRate-4992k 1055\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5120k 1056\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5248k 1057\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5376k 1058\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5504k 1059\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5632k 1060\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5760k 1061\r
-VALUE KarlNet-TurboCell-TxRate TxRate-5888k 1062\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6016k 1063\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6144k 1064\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6272k 1065\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6400k 1066\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6528k 1067\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6656k 1068\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6784k 1069\r
-VALUE KarlNet-TurboCell-TxRate TxRate-6912k 1070\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7040k 1071\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7168k 1072\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7296k 1073\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7424k 1074\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7552k 1075\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7680k 1076\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7808k 1077\r
-VALUE KarlNet-TurboCell-TxRate TxRate-7936k 1078\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8064k 1079\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8192k 1080\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8320k 1081\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8448k 1082\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8576k 1083\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8704k 1084\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8832k 1085\r
-VALUE KarlNet-TurboCell-TxRate TxRate-8960k 1086\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9088k 1087\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9216k 1088\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9344k 1089\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9472k 1090\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9600k 1091\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9728k 1092\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9856k 1093\r
-VALUE KarlNet-TurboCell-TxRate TxRate-9984k 1094\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10112k 1095\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10240k 1096\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10368k 1097\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10496k 1098\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10624k 1099\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10752k 1100\r
-VALUE KarlNet-TurboCell-TxRate TxRate-10880k 1101\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11008k 1102\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11136k 1103\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11264k 1104\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11392k 1105\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11520k 1106\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11648k 1107\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11776k 1108\r
-VALUE KarlNet-TurboCell-TxRate TxRate-11904k 1109\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12032k 1110\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12160k 1111\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12288k 1112\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12416k 1113\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12544k 1114\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12672k 1115\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12800k 1116\r
-VALUE KarlNet-TurboCell-TxRate TxRate-12928k 1117\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13056k 1118\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13184k 1119\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13312k 1120\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13440k 1121\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13568k 1122\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13696k 1123\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13824k 1124\r
-VALUE KarlNet-TurboCell-TxRate TxRate-13952k 1125\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14080k 1126\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14208k 1127\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14336k 1128\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14464k 1129\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14592k 1130\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14720k 1131\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14848k 1132\r
-VALUE KarlNet-TurboCell-TxRate TxRate-14976k 1133\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15104k 1134\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15232k 1135\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15360k 1136\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15488k 1137\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15616k 1138\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15744k 1139\r
-VALUE KarlNet-TurboCell-TxRate TxRate-15872k 1140\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16000k 1141\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16128k 1142\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16256k 1143\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16384k 1144\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16512k 1145\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16640k 1146\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16768k 1147\r
-VALUE KarlNet-TurboCell-TxRate TxRate-16896k 1148\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17024k 1149\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17152k 1150\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17280k 1151\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17408k 1152\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17536k 1153\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17664k 1154\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17792k 1155\r
-VALUE KarlNet-TurboCell-TxRate TxRate-17920k 1156\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18048k 1157\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18176k 1158\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18304k 1159\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18432k 1160\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18560k 1161\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18688k 1162\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18816k 1163\r
-VALUE KarlNet-TurboCell-TxRate TxRate-18944k 1164\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19072k 1165\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19200k 1166\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19328k 1167\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19456k 1168\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19584k 1169\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19712k 1170\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19840k 1171\r
-VALUE KarlNet-TurboCell-TxRate TxRate-19968k 1172\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20096k 1173\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20224k 1174\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20352k 1175\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20480k 1176\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20608k 1177\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20736k 1178\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20864k 1179\r
-VALUE KarlNet-TurboCell-TxRate TxRate-20992k 1180\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21120k 1181\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21248k 1182\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21376k 1183\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21504k 1184\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21632k 1185\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21760k 1186\r
-VALUE KarlNet-TurboCell-TxRate TxRate-21888k 1187\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22016k 1188\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22144k 1189\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22272k 1190\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22400k 1191\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22528k 1192\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22656k 1193\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22784k 1194\r
-VALUE KarlNet-TurboCell-TxRate TxRate-22912k 1195\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23040k 1196\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23168k 1197\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23296k 1198\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23424k 1199\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23552k 1200\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23680k 1201\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23808k 1202\r
-VALUE KarlNet-TurboCell-TxRate TxRate-23936k 1203\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24064k 1204\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24192k 1205\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24320k 1206\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24448k 1207\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24576k 1208\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24704k 1209\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24832k 1210\r
-VALUE KarlNet-TurboCell-TxRate TxRate-24960k 1211\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25088k 1212\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25216k 1213\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25344k 1214\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25472k 1215\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25600k 1216\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25728k 1217\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25856k 1218\r
-VALUE KarlNet-TurboCell-TxRate TxRate-25984k 1219\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26112k 1220\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26240k 1221\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26368k 1222\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26496k 1223\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26624k 1224\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26752k 1225\r
-VALUE KarlNet-TurboCell-TxRate TxRate-26880k 1226\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27008k 1227\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27136k 1228\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27264k 1229\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27392k 1230\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27520k 1231\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27648k 1232\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27776k 1233\r
-VALUE KarlNet-TurboCell-TxRate TxRate-27904k 1234\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28032k 1235\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28160k 1236\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28288k 1237\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28416k 1238\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28544k 1239\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28672k 1240\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28800k 1241\r
-VALUE KarlNet-TurboCell-TxRate TxRate-28928k 1242\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29056k 1243\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29184k 1244\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29312k 1245\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29440k 1246\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29568k 1247\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29696k 1248\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29824k 1249\r
-VALUE KarlNet-TurboCell-TxRate TxRate-29952k 1250\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30080k 1251\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30208k 1252\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30336k 1253\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30464k 1254\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30592k 1255\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30720k 1256\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30848k 1257\r
-VALUE KarlNet-TurboCell-TxRate TxRate-30976k 1258\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31104k 1259\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31232k 1260\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31360k 1261\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31488k 1262\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31616k 1263\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31744k 1264\r
-VALUE KarlNet-TurboCell-TxRate TxRate-31872k 1265\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32000k 1266\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32128k 1267\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32256k 1268\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32384k 1269\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32512k 1270\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32640k 1271\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32768k 1272\r
-VALUE KarlNet-TurboCell-TxRate TxRate-32896k 1273\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33024k 1274\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33152k 1275\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33280k 1276\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33408k 1277\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33536k 1278\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33664k 1279\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33792k 1280\r
-VALUE KarlNet-TurboCell-TxRate TxRate-33920k 1281\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34048k 1282\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34176k 1283\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34304k 1284\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34432k 1285\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34560k 1286\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34688k 1287\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34816k 1288\r
-VALUE KarlNet-TurboCell-TxRate TxRate-34944k 1289\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35072k 1290\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35200k 1291\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35328k 1292\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35456k 1293\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35584k 1294\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35712k 1295\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35840k 1296\r
-VALUE KarlNet-TurboCell-TxRate TxRate-35968k 1297\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36096k 1298\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36224k 1299\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36352k 1300\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36480k 1301\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36608k 1302\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36736k 1303\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36864k 1304\r
-VALUE KarlNet-TurboCell-TxRate TxRate-36992k 1305\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37120k 1306\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37248k 1307\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37376k 1308\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37504k 1309\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37632k 1310\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37760k 1311\r
-VALUE KarlNet-TurboCell-TxRate TxRate-37888k 1312\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38016k 1313\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38144k 1314\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38272k 1315\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38400k 1316\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38528k 1317\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38656k 1318\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38784k 1319\r
-VALUE KarlNet-TurboCell-TxRate TxRate-38912k 1320\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39040k 1321\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39168k 1322\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39296k 1323\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39424k 1324\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39552k 1325\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39680k 1326\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39808k 1327\r
-VALUE KarlNet-TurboCell-TxRate TxRate-39936k 1328\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40064k 1329\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40192k 1330\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40320k 1331\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40448k 1332\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40576k 1333\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40704k 1334\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40832k 1335\r
-VALUE KarlNet-TurboCell-TxRate TxRate-40960k 1336\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41088k 1337\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41216k 1338\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41344k 1339\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41472k 1340\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41600k 1341\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41728k 1342\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41856k 1343\r
-VALUE KarlNet-TurboCell-TxRate TxRate-41984k 1344\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42112k 1345\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42240k 1346\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42368k 1347\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42496k 1348\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42624k 1349\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42752k 1350\r
-VALUE KarlNet-TurboCell-TxRate TxRate-42880k 1351\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43008k 1352\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43136k 1353\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43264k 1354\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43392k 1355\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43520k 1356\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43648k 1357\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43776k 1358\r
-VALUE KarlNet-TurboCell-TxRate TxRate-43904k 1359\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44032k 1360\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44160k 1361\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44288k 1362\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44416k 1363\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44544k 1364\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44672k 1365\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44800k 1366\r
-VALUE KarlNet-TurboCell-TxRate TxRate-44928k 1367\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45056k 1368\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45184k 1369\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45312k 1370\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45440k 1371\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45568k 1372\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45696k 1373\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45824k 1374\r
-VALUE KarlNet-TurboCell-TxRate TxRate-45952k 1375\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46080k 1376\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46208k 1377\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46336k 1378\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46464k 1379\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46592k 1380\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46720k 1381\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46848k 1382\r
-VALUE KarlNet-TurboCell-TxRate TxRate-46976k 1383\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47104k 1384\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47232k 1385\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47360k 1386\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47488k 1387\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47616k 1388\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47744k 1389\r
-VALUE KarlNet-TurboCell-TxRate TxRate-47872k 1390\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48000k 1391\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48128k 1392\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48256k 1393\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48384k 1394\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48512k 1395\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48640k 1396\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48768k 1397\r
-VALUE KarlNet-TurboCell-TxRate TxRate-48896k 1398\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49024k 1399\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49152k 1400\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49280k 1401\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49408k 1402\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49536k 1403\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49664k 1404\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49792k 1405\r
-VALUE KarlNet-TurboCell-TxRate TxRate-49920k 1406\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50048k 1407\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50176k 1408\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50304k 1409\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50432k 1410\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50560k 1411\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50688k 1412\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50816k 1413\r
-VALUE KarlNet-TurboCell-TxRate TxRate-50944k 1414\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51072k 1415\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51200k 1416\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51328k 1417\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51456k 1418\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51584k 1419\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51712k 1420\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51840k 1421\r
-VALUE KarlNet-TurboCell-TxRate TxRate-51968k 1422\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52096k 1423\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52224k 1424\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52352k 1425\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52480k 1426\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52608k 1427\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52736k 1428\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52864k 1429\r
-VALUE KarlNet-TurboCell-TxRate TxRate-52992k 1430\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53120k 1431\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53248k 1432\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53376k 1433\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53504k 1434\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53632k 1435\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53760k 1436\r
-VALUE KarlNet-TurboCell-TxRate TxRate-53888k 1437\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54016k 1438\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54144k 1439\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54272k 1440\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54400k 1441\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54528k 1442\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54656k 1443\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54784k 1444\r
-VALUE KarlNet-TurboCell-TxRate TxRate-54912k 1445\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55040k 1446\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55168k 1447\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55296k 1448\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55424k 1449\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55552k 1450\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55680k 1451\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55808k 1452\r
-VALUE KarlNet-TurboCell-TxRate TxRate-55936k 1453\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56064k 1454\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56192k 1455\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56320k 1456\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56448k 1457\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56576k 1458\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56704k 1459\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56832k 1460\r
-VALUE KarlNet-TurboCell-TxRate TxRate-56960k 1461\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57088k 1462\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57216k 1463\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57344k 1464\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57472k 1465\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57600k 1466\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57728k 1467\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57856k 1468\r
-VALUE KarlNet-TurboCell-TxRate TxRate-57984k 1469\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58112k 1470\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58240k 1471\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58368k 1472\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58496k 1473\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58624k 1474\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58752k 1475\r
-VALUE KarlNet-TurboCell-TxRate TxRate-58880k 1476\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59008k 1477\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59136k 1478\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59264k 1479\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59392k 1480\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59520k 1481\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59648k 1482\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59776k 1483\r
-VALUE KarlNet-TurboCell-TxRate TxRate-59904k 1484\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60032k 1485\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60160k 1486\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60288k 1487\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60416k 1488\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60544k 1489\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60672k 1490\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60800k 1491\r
-VALUE KarlNet-TurboCell-TxRate TxRate-60928k 1492\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61056k 1493\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61184k 1494\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61312k 1495\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61440k 1496\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61568k 1497\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61696k 1498\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61824k 1499\r
-VALUE KarlNet-TurboCell-TxRate TxRate-61952k 1500\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62080k 1501\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62208k 1502\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62336k 1503\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62464k 1504\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62592k 1505\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62720k 1506\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62848k 1507\r
-VALUE KarlNet-TurboCell-TxRate TxRate-62976k 1508\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63104k 1509\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63232k 1510\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63360k 1511\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63488k 1512\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63616k 1513\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63744k 1514\r
-VALUE KarlNet-TurboCell-TxRate TxRate-63872k 1515\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64000k 1516\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64128k 1517\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64256k 1518\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64384k 1519\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64512k 1520\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64640k 1521\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64768k 1522\r
-VALUE KarlNet-TurboCell-TxRate TxRate-64896k 1523\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65024k 1524\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65152k 1525\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65280k 1526\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65408k 1527\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65536k 1528\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65664k 1529\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65792k 1530\r
-VALUE KarlNet-TurboCell-TxRate TxRate-65920k 1531\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66048k 1532\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66176k 1533\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66304k 1534\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66432k 1535\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66560k 1536\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66688k 1537\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66816k 1538\r
-VALUE KarlNet-TurboCell-TxRate TxRate-66944k 1539\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67072k 1540\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67200k 1541\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67328k 1542\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67456k 1543\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67584k 1544\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67712k 1545\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67840k 1546\r
-VALUE KarlNet-TurboCell-TxRate TxRate-67968k 1547\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68096k 1548\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68224k 1549\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68352k 1550\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68480k 1551\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68608k 1552\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68736k 1553\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68864k 1554\r
-VALUE KarlNet-TurboCell-TxRate TxRate-68992k 1555\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69120k 1556\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69248k 1557\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69376k 1558\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69504k 1559\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69632k 1560\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69760k 1561\r
-VALUE KarlNet-TurboCell-TxRate TxRate-69888k 1562\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70016k 1563\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70144k 1564\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70272k 1565\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70400k 1566\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70528k 1567\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70656k 1568\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70784k 1569\r
-VALUE KarlNet-TurboCell-TxRate TxRate-70912k 1570\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71040k 1571\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71168k 1572\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71296k 1573\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71424k 1574\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71552k 1575\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71680k 1576\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71808k 1577\r
-VALUE KarlNet-TurboCell-TxRate TxRate-71936k 1578\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72064k 1579\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72192k 1580\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72320k 1581\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72448k 1582\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72576k 1583\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72704k 1584\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72832k 1585\r
-VALUE KarlNet-TurboCell-TxRate TxRate-72960k 1586\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73088k 1587\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73216k 1588\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73344k 1589\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73472k 1590\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73600k 1591\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73728k 1592\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73856k 1593\r
-VALUE KarlNet-TurboCell-TxRate TxRate-73984k 1594\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74112k 1595\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74240k 1596\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74368k 1597\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74496k 1598\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74624k 1599\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74752k 1600\r
-VALUE KarlNet-TurboCell-TxRate TxRate-74880k 1601\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75008k 1602\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75136k 1603\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75264k 1604\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75392k 1605\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75520k 1606\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75648k 1607\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75776k 1608\r
-VALUE KarlNet-TurboCell-TxRate TxRate-75904k 1609\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76032k 1610\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76160k 1611\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76288k 1612\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76416k 1613\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76544k 1614\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76672k 1615\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76800k 1616\r
-VALUE KarlNet-TurboCell-TxRate TxRate-76928k 1617\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77056k 1618\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77184k 1619\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77312k 1620\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77440k 1621\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77568k 1622\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77696k 1623\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77824k 1624\r
-VALUE KarlNet-TurboCell-TxRate TxRate-77952k 1625\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78080k 1626\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78208k 1627\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78336k 1628\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78464k 1629\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78592k 1630\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78720k 1631\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78848k 1632\r
-VALUE KarlNet-TurboCell-TxRate TxRate-78976k 1633\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79104k 1634\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79232k 1635\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79360k 1636\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79488k 1637\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79616k 1638\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79744k 1639\r
-VALUE KarlNet-TurboCell-TxRate TxRate-79872k 1640\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80000k 1641\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80128k 1642\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80256k 1643\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80384k 1644\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80512k 1645\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80640k 1646\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80768k 1647\r
-VALUE KarlNet-TurboCell-TxRate TxRate-80896k 1648\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81024k 1649\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81152k 1650\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81280k 1651\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81408k 1652\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81536k 1653\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81664k 1654\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81792k 1655\r
-VALUE KarlNet-TurboCell-TxRate TxRate-81920k 1656\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82048k 1657\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82176k 1658\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82304k 1659\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82432k 1660\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82560k 1661\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82688k 1662\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82816k 1663\r
-VALUE KarlNet-TurboCell-TxRate TxRate-82944k 1664\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83072k 1665\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83200k 1666\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83328k 1667\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83456k 1668\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83584k 1669\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83712k 1670\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83840k 1671\r
-VALUE KarlNet-TurboCell-TxRate TxRate-83968k 1672\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84096k 1673\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84224k 1674\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84352k 1675\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84480k 1676\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84608k 1677\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84736k 1678\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84864k 1679\r
-VALUE KarlNet-TurboCell-TxRate TxRate-84992k 1680\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85120k 1681\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85248k 1682\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85376k 1683\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85504k 1684\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85632k 1685\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85760k 1686\r
-VALUE KarlNet-TurboCell-TxRate TxRate-85888k 1687\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86016k 1688\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86144k 1689\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86272k 1690\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86400k 1691\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86528k 1692\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86656k 1693\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86784k 1694\r
-VALUE KarlNet-TurboCell-TxRate TxRate-86912k 1695\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87040k 1696\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87168k 1697\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87296k 1698\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87424k 1699\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87552k 1700\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87680k 1701\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87808k 1702\r
-VALUE KarlNet-TurboCell-TxRate TxRate-87936k 1703\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88064k 1704\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88192k 1705\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88320k 1706\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88448k 1707\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88576k 1708\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88704k 1709\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88832k 1710\r
-VALUE KarlNet-TurboCell-TxRate TxRate-88960k 1711\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89088k 1712\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89216k 1713\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89344k 1714\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89472k 1715\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89600k 1716\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89728k 1717\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89856k 1718\r
-VALUE KarlNet-TurboCell-TxRate TxRate-89984k 1719\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90112k 1720\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90240k 1721\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90368k 1722\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90496k 1723\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90624k 1724\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90752k 1725\r
-VALUE KarlNet-TurboCell-TxRate TxRate-90880k 1726\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91008k 1727\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91136k 1728\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91264k 1729\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91392k 1730\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91520k 1731\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91648k 1732\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91776k 1733\r
-VALUE KarlNet-TurboCell-TxRate TxRate-91904k 1734\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92032k 1735\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92160k 1736\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92288k 1737\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92416k 1738\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92544k 1739\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92672k 1740\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92800k 1741\r
-VALUE KarlNet-TurboCell-TxRate TxRate-92928k 1742\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93056k 1743\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93184k 1744\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93312k 1745\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93440k 1746\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93568k 1747\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93696k 1748\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93824k 1749\r
-VALUE KarlNet-TurboCell-TxRate TxRate-93952k 1750\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94080k 1751\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94208k 1752\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94336k 1753\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94464k 1754\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94592k 1755\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94720k 1756\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94848k 1757\r
-VALUE KarlNet-TurboCell-TxRate TxRate-94976k 1758\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95104k 1759\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95232k 1760\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95360k 1761\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95488k 1762\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95616k 1763\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95744k 1764\r
-VALUE KarlNet-TurboCell-TxRate TxRate-95872k 1765\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96000k 1766\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96128k 1767\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96256k 1768\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96384k 1769\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96512k 1770\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96640k 1771\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96768k 1772\r
-VALUE KarlNet-TurboCell-TxRate TxRate-96896k 1773\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97024k 1774\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97152k 1775\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97280k 1776\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97408k 1777\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97536k 1778\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97664k 1779\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97792k 1780\r
-VALUE KarlNet-TurboCell-TxRate TxRate-97920k 1781\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98048k 1782\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98176k 1783\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98304k 1784\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98432k 1785\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98560k 1786\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98688k 1787\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98816k 1788\r
-VALUE KarlNet-TurboCell-TxRate TxRate-98944k 1789\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99072k 1790\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99200k 1791\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99328k 1792\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99456k 1793\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99584k 1794\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99712k 1795\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99840k 1796\r
-VALUE KarlNet-TurboCell-TxRate TxRate-99968k 1797\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100096k 1798\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100224k 1799\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100352k 1800\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100480k 1801\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100608k 1802\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100736k 1803\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100864k 1804\r
-VALUE KarlNet-TurboCell-TxRate TxRate-100992k 1805\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101120k 1806\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101248k 1807\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101376k 1808\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101504k 1809\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101632k 1810\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101760k 1811\r
-VALUE KarlNet-TurboCell-TxRate TxRate-101888k 1812\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102016k 1813\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102144k 1814\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102272k 1815\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102400k 1816\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102528k 1817\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102656k 1818\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102784k 1819\r
-VALUE KarlNet-TurboCell-TxRate TxRate-102912k 1820\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103040k 1821\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103168k 1822\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103296k 1823\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103424k 1824\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103552k 1825\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103680k 1826\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103808k 1827\r
-VALUE KarlNet-TurboCell-TxRate TxRate-103936k 1828\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104064k 1829\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104192k 1830\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104320k 1831\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104448k 1832\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104576k 1833\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104704k 1834\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104832k 1835\r
-VALUE KarlNet-TurboCell-TxRate TxRate-104960k 1836\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105088k 1837\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105216k 1838\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105344k 1839\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105472k 1840\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105600k 1841\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105728k 1842\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105856k 1843\r
-VALUE KarlNet-TurboCell-TxRate TxRate-105984k 1844\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106112k 1845\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106240k 1846\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106368k 1847\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106496k 1848\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106624k 1849\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106752k 1850\r
-VALUE KarlNet-TurboCell-TxRate TxRate-106880k 1851\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107008k 1852\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107136k 1853\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107264k 1854\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107392k 1855\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107520k 1856\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107648k 1857\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107776k 1858\r
-VALUE KarlNet-TurboCell-TxRate TxRate-107904k 1859\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108032k 1860\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108160k 1861\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108288k 1862\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108416k 1863\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108544k 1864\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108672k 1865\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108800k 1866\r
-VALUE KarlNet-TurboCell-TxRate TxRate-108928k 1867\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109056k 1868\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109184k 1869\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109312k 1870\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109440k 1871\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109568k 1872\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109696k 1873\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109824k 1874\r
-VALUE KarlNet-TurboCell-TxRate TxRate-109952k 1875\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110080k 1876\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110208k 1877\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110336k 1878\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110464k 1879\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110592k 1880\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110720k 1881\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110848k 1882\r
-VALUE KarlNet-TurboCell-TxRate TxRate-110976k 1883\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111104k 1884\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111232k 1885\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111360k 1886\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111488k 1887\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111616k 1888\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111744k 1889\r
-VALUE KarlNet-TurboCell-TxRate TxRate-111872k 1890\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112000k 1891\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112128k 1892\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112256k 1893\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112384k 1894\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112512k 1895\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112640k 1896\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112768k 1897\r
-VALUE KarlNet-TurboCell-TxRate TxRate-112896k 1898\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113024k 1899\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113152k 1900\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113280k 1901\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113408k 1902\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113536k 1903\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113664k 1904\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113792k 1905\r
-VALUE KarlNet-TurboCell-TxRate TxRate-113920k 1906\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114048k 1907\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114176k 1908\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114304k 1909\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114432k 1910\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114560k 1911\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114688k 1912\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114816k 1913\r
-VALUE KarlNet-TurboCell-TxRate TxRate-114944k 1914\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115072k 1915\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115200k 1916\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115328k 1917\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115456k 1918\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115584k 1919\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115712k 1920\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115840k 1921\r
-VALUE KarlNet-TurboCell-TxRate TxRate-115968k 1922\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116096k 1923\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116224k 1924\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116352k 1925\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116480k 1926\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116608k 1927\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116736k 1928\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116864k 1929\r
-VALUE KarlNet-TurboCell-TxRate TxRate-116992k 1930\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117120k 1931\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117248k 1932\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117376k 1933\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117504k 1934\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117632k 1935\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117760k 1936\r
-VALUE KarlNet-TurboCell-TxRate TxRate-117888k 1937\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118016k 1938\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118144k 1939\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118272k 1940\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118400k 1941\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118528k 1942\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118656k 1943\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118784k 1944\r
-VALUE KarlNet-TurboCell-TxRate TxRate-118912k 1945\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119040k 1946\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119168k 1947\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119296k 1948\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119424k 1949\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119552k 1950\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119680k 1951\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119808k 1952\r
-VALUE KarlNet-TurboCell-TxRate TxRate-119936k 1953\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120064k 1954\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120192k 1955\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120320k 1956\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120448k 1957\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120576k 1958\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120704k 1959\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120832k 1960\r
-VALUE KarlNet-TurboCell-TxRate TxRate-120960k 1961\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121088k 1962\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121216k 1963\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121344k 1964\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121472k 1965\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121600k 1966\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121728k 1967\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121856k 1968\r
-VALUE KarlNet-TurboCell-TxRate TxRate-121984k 1969\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122112k 1970\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122240k 1971\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122368k 1972\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122496k 1973\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122624k 1974\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122752k 1975\r
-VALUE KarlNet-TurboCell-TxRate TxRate-122880k 1976\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123008k 1977\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123136k 1978\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123264k 1979\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123392k 1980\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123520k 1981\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123648k 1982\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123776k 1983\r
-VALUE KarlNet-TurboCell-TxRate TxRate-123904k 1984\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124032k 1985\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124160k 1986\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124288k 1987\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124416k 1988\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124544k 1989\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124672k 1990\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124800k 1991\r
-VALUE KarlNet-TurboCell-TxRate TxRate-124928k 1992\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125056k 1993\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125184k 1994\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125312k 1995\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125440k 1996\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125568k 1997\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125696k 1998\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125824k 1999\r
-VALUE KarlNet-TurboCell-TxRate TxRate-125952k 2000\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126080k 2001\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126208k 2002\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126336k 2003\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126464k 2004\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126592k 2005\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126720k 2006\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126848k 2007\r
-VALUE KarlNet-TurboCell-TxRate TxRate-126976k 2008\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127104k 2009\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127232k 2010\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127360k 2011\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127488k 2012\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127616k 2013\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127744k 2014\r
-VALUE KarlNet-TurboCell-TxRate TxRate-127872k 2015\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128000k 2016\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128128k 2017\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128256k 2018\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128384k 2019\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128512k 2020\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128640k 2021\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128768k 2022\r
-VALUE KarlNet-TurboCell-TxRate TxRate-128896k 2023\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129024k 2024\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129152k 2025\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129280k 2026\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129408k 2027\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129536k 2028\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129664k 2029\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129792k 2030\r
-VALUE KarlNet-TurboCell-TxRate TxRate-129920k 2031\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130048k 2032\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130176k 2033\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130304k 2034\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130432k 2035\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130560k 2036\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130688k 2037\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130816k 2038\r
-VALUE KarlNet-TurboCell-TxRate TxRate-130944k 2039\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131072k 2040\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131200k 2041\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131328k 2042\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131456k 2043\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131584k 2044\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131712k 2045\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131840k 2046\r
-VALUE KarlNet-TurboCell-TxRate TxRate-131968k 2047\r
-\r
-\r
-\r
-# Sets the remote client's Operating State\r
-ATTRIBUTE KarlNet-TurboCell-OpState 153 integer KarlNet\r
-VALUE KarlNet-TurboCell-OpState Up 0\r
-VALUE KarlNet-TurboCell-OpState Down 1\r
-\r
-# Sets the remote client's Operating Mode\r
-ATTRIBUTE KarlNet-TurboCell-OpMode 154 integer KarlNet\r
-VALUE KarlNet-TurboCell-OpMode Peer-to-Peer 0\r
-VALUE KarlNet-TurboCell-OpMode Base 1\r
-VALUE KarlNet-TurboCell-OpMode Base-Polling 2\r
-VALUE KarlNet-TurboCell-OpMode Satellite-NT 3\r
-\r
-# ----------------------------------------------\r
-# END OF KarlNet Vendor-specific information\r
-# ----------------------------------------------\r
-\r
-\r
-\r
+# -*- text -*-
+# --------------------------------------
+# KarlNet Vendor-specific information
+# --------------------------------------
+
+#---------------------------------------------------------------------------
+# "VENDOR" VENDOR-NAME VENDOR-ID
+#---------------------------------------------------------------------------
+VENDOR KarlNet 762
+
+#---------------------------------------------------------------------------
+# "ATTRIBUTE" ATTRIBUTE-NAME ATTR-NUMBER ATTRTYPE VENDOR-NAME
+#---------------------------------------------------------------------------
+# Sets the remote client's Station Name
+BEGIN-VENDOR KarlNet
+
+ATTRIBUTE KarlNet-TurboCell-Name 151 string
+
+# Sets the remote client's Data Transmit Rate
+ATTRIBUTE KarlNet-TurboCell-TxRate 152 integer
+
+#---------------------------------------------------------------------------
+# "VALUE" ATTRIBUTE-NAME SETTING-NAME SETTING-VALUE
+#---------------------------------------------------------------------------
+# 0x00 // Use the locally defined Data Rate
+VALUE KarlNet-TurboCell-TxRate TxRate-Local 0
+# 0x08 // Use the maximum data rate possible
+VALUE KarlNet-TurboCell-TxRate TxRate-MaxSpeed 8
+
+VALUE KarlNet-TurboCell-TxRate TxRate-11k 11
+VALUE KarlNet-TurboCell-TxRate TxRate-12k 12
+VALUE KarlNet-TurboCell-TxRate TxRate-13k 13
+VALUE KarlNet-TurboCell-TxRate TxRate-14k 14
+VALUE KarlNet-TurboCell-TxRate TxRate-15k 15
+VALUE KarlNet-TurboCell-TxRate TxRate-16k 16
+VALUE KarlNet-TurboCell-TxRate TxRate-17k 17
+VALUE KarlNet-TurboCell-TxRate TxRate-18k 18
+VALUE KarlNet-TurboCell-TxRate TxRate-19k 19
+VALUE KarlNet-TurboCell-TxRate TxRate-20k 20
+VALUE KarlNet-TurboCell-TxRate TxRate-21k 21
+VALUE KarlNet-TurboCell-TxRate TxRate-22k 22
+VALUE KarlNet-TurboCell-TxRate TxRate-23k 23
+VALUE KarlNet-TurboCell-TxRate TxRate-24k 24
+VALUE KarlNet-TurboCell-TxRate TxRate-25k 25
+VALUE KarlNet-TurboCell-TxRate TxRate-26k 26
+VALUE KarlNet-TurboCell-TxRate TxRate-27k 27
+VALUE KarlNet-TurboCell-TxRate TxRate-28k 28
+VALUE KarlNet-TurboCell-TxRate TxRate-29k 29
+VALUE KarlNet-TurboCell-TxRate TxRate-30k 30
+VALUE KarlNet-TurboCell-TxRate TxRate-31k 31
+VALUE KarlNet-TurboCell-TxRate TxRate-32k 32
+VALUE KarlNet-TurboCell-TxRate TxRate-33k 33
+VALUE KarlNet-TurboCell-TxRate TxRate-34k 34
+VALUE KarlNet-TurboCell-TxRate TxRate-35k 35
+VALUE KarlNet-TurboCell-TxRate TxRate-36k 36
+VALUE KarlNet-TurboCell-TxRate TxRate-37k 37
+VALUE KarlNet-TurboCell-TxRate TxRate-38k 38
+VALUE KarlNet-TurboCell-TxRate TxRate-39k 39
+VALUE KarlNet-TurboCell-TxRate TxRate-40k 40
+VALUE KarlNet-TurboCell-TxRate TxRate-41k 41
+VALUE KarlNet-TurboCell-TxRate TxRate-42k 42
+VALUE KarlNet-TurboCell-TxRate TxRate-43k 43
+VALUE KarlNet-TurboCell-TxRate TxRate-44k 44
+VALUE KarlNet-TurboCell-TxRate TxRate-45k 45
+VALUE KarlNet-TurboCell-TxRate TxRate-46k 46
+VALUE KarlNet-TurboCell-TxRate TxRate-47k 47
+VALUE KarlNet-TurboCell-TxRate TxRate-48k 48
+VALUE KarlNet-TurboCell-TxRate TxRate-49k 49
+VALUE KarlNet-TurboCell-TxRate TxRate-50k 50
+VALUE KarlNet-TurboCell-TxRate TxRate-51k 51
+VALUE KarlNet-TurboCell-TxRate TxRate-52k 52
+VALUE KarlNet-TurboCell-TxRate TxRate-53k 53
+VALUE KarlNet-TurboCell-TxRate TxRate-54k 54
+VALUE KarlNet-TurboCell-TxRate TxRate-55k 55
+VALUE KarlNet-TurboCell-TxRate TxRate-56k 56
+VALUE KarlNet-TurboCell-TxRate TxRate-57k 57
+VALUE KarlNet-TurboCell-TxRate TxRate-58k 58
+VALUE KarlNet-TurboCell-TxRate TxRate-59k 59
+VALUE KarlNet-TurboCell-TxRate TxRate-60k 60
+VALUE KarlNet-TurboCell-TxRate TxRate-61k 61
+VALUE KarlNet-TurboCell-TxRate TxRate-62k 62
+VALUE KarlNet-TurboCell-TxRate TxRate-63k 63
+VALUE KarlNet-TurboCell-TxRate TxRate-64k 64
+VALUE KarlNet-TurboCell-TxRate TxRate-65k 65
+VALUE KarlNet-TurboCell-TxRate TxRate-66k 66
+VALUE KarlNet-TurboCell-TxRate TxRate-67k 67
+VALUE KarlNet-TurboCell-TxRate TxRate-68k 68
+VALUE KarlNet-TurboCell-TxRate TxRate-69k 69
+VALUE KarlNet-TurboCell-TxRate TxRate-70k 70
+VALUE KarlNet-TurboCell-TxRate TxRate-71k 71
+VALUE KarlNet-TurboCell-TxRate TxRate-72k 72
+VALUE KarlNet-TurboCell-TxRate TxRate-73k 73
+VALUE KarlNet-TurboCell-TxRate TxRate-74k 74
+VALUE KarlNet-TurboCell-TxRate TxRate-75k 75
+VALUE KarlNet-TurboCell-TxRate TxRate-76k 76
+VALUE KarlNet-TurboCell-TxRate TxRate-77k 77
+VALUE KarlNet-TurboCell-TxRate TxRate-78k 78
+VALUE KarlNet-TurboCell-TxRate TxRate-79k 79
+VALUE KarlNet-TurboCell-TxRate TxRate-80k 80
+VALUE KarlNet-TurboCell-TxRate TxRate-81k 81
+VALUE KarlNet-TurboCell-TxRate TxRate-82k 82
+VALUE KarlNet-TurboCell-TxRate TxRate-83k 83
+VALUE KarlNet-TurboCell-TxRate TxRate-84k 84
+VALUE KarlNet-TurboCell-TxRate TxRate-85k 85
+VALUE KarlNet-TurboCell-TxRate TxRate-86k 86
+VALUE KarlNet-TurboCell-TxRate TxRate-87k 87
+VALUE KarlNet-TurboCell-TxRate TxRate-88k 88
+VALUE KarlNet-TurboCell-TxRate TxRate-89k 89
+VALUE KarlNet-TurboCell-TxRate TxRate-90k 90
+VALUE KarlNet-TurboCell-TxRate TxRate-91k 91
+VALUE KarlNet-TurboCell-TxRate TxRate-92k 92
+VALUE KarlNet-TurboCell-TxRate TxRate-93k 93
+VALUE KarlNet-TurboCell-TxRate TxRate-94k 94
+VALUE KarlNet-TurboCell-TxRate TxRate-95k 95
+VALUE KarlNet-TurboCell-TxRate TxRate-96k 96
+VALUE KarlNet-TurboCell-TxRate TxRate-97k 97
+VALUE KarlNet-TurboCell-TxRate TxRate-98k 98
+VALUE KarlNet-TurboCell-TxRate TxRate-99k 99
+VALUE KarlNet-TurboCell-TxRate TxRate-100k 100
+VALUE KarlNet-TurboCell-TxRate TxRate-101k 101
+VALUE KarlNet-TurboCell-TxRate TxRate-102k 102
+VALUE KarlNet-TurboCell-TxRate TxRate-103k 103
+VALUE KarlNet-TurboCell-TxRate TxRate-104k 104
+VALUE KarlNet-TurboCell-TxRate TxRate-105k 105
+VALUE KarlNet-TurboCell-TxRate TxRate-106k 106
+VALUE KarlNet-TurboCell-TxRate TxRate-107k 107
+VALUE KarlNet-TurboCell-TxRate TxRate-108k 108
+VALUE KarlNet-TurboCell-TxRate TxRate-109k 109
+VALUE KarlNet-TurboCell-TxRate TxRate-110k 110
+VALUE KarlNet-TurboCell-TxRate TxRate-111k 111
+VALUE KarlNet-TurboCell-TxRate TxRate-112k 112
+VALUE KarlNet-TurboCell-TxRate TxRate-113k 113
+VALUE KarlNet-TurboCell-TxRate TxRate-114k 114
+VALUE KarlNet-TurboCell-TxRate TxRate-115k 115
+VALUE KarlNet-TurboCell-TxRate TxRate-116k 116
+VALUE KarlNet-TurboCell-TxRate TxRate-117k 117
+VALUE KarlNet-TurboCell-TxRate TxRate-118k 118
+VALUE KarlNet-TurboCell-TxRate TxRate-119k 119
+VALUE KarlNet-TurboCell-TxRate TxRate-120k 120
+VALUE KarlNet-TurboCell-TxRate TxRate-121k 121
+VALUE KarlNet-TurboCell-TxRate TxRate-122k 122
+VALUE KarlNet-TurboCell-TxRate TxRate-123k 123
+VALUE KarlNet-TurboCell-TxRate TxRate-124k 124
+VALUE KarlNet-TurboCell-TxRate TxRate-125k 125
+VALUE KarlNet-TurboCell-TxRate TxRate-126k 126
+VALUE KarlNet-TurboCell-TxRate TxRate-127k 127
+VALUE KarlNet-TurboCell-TxRate TxRate-128k 128
+VALUE KarlNet-TurboCell-TxRate TxRate-129k 129
+VALUE KarlNet-TurboCell-TxRate TxRate-130k 130
+VALUE KarlNet-TurboCell-TxRate TxRate-131k 131
+VALUE KarlNet-TurboCell-TxRate TxRate-132k 132
+VALUE KarlNet-TurboCell-TxRate TxRate-133k 133
+VALUE KarlNet-TurboCell-TxRate TxRate-134k 134
+VALUE KarlNet-TurboCell-TxRate TxRate-135k 135
+VALUE KarlNet-TurboCell-TxRate TxRate-136k 136
+VALUE KarlNet-TurboCell-TxRate TxRate-137k 137
+VALUE KarlNet-TurboCell-TxRate TxRate-138k 138
+VALUE KarlNet-TurboCell-TxRate TxRate-139k 139
+VALUE KarlNet-TurboCell-TxRate TxRate-140k 140
+VALUE KarlNet-TurboCell-TxRate TxRate-141k 141
+VALUE KarlNet-TurboCell-TxRate TxRate-142k 142
+VALUE KarlNet-TurboCell-TxRate TxRate-143k 143
+VALUE KarlNet-TurboCell-TxRate TxRate-144k 144
+VALUE KarlNet-TurboCell-TxRate TxRate-145k 145
+VALUE KarlNet-TurboCell-TxRate TxRate-146k 146
+VALUE KarlNet-TurboCell-TxRate TxRate-147k 147
+VALUE KarlNet-TurboCell-TxRate TxRate-148k 148
+VALUE KarlNet-TurboCell-TxRate TxRate-149k 149
+VALUE KarlNet-TurboCell-TxRate TxRate-150k 150
+VALUE KarlNet-TurboCell-TxRate TxRate-151k 151
+VALUE KarlNet-TurboCell-TxRate TxRate-152k 152
+VALUE KarlNet-TurboCell-TxRate TxRate-153k 153
+VALUE KarlNet-TurboCell-TxRate TxRate-154k 154
+VALUE KarlNet-TurboCell-TxRate TxRate-155k 155
+VALUE KarlNet-TurboCell-TxRate TxRate-156k 156
+VALUE KarlNet-TurboCell-TxRate TxRate-157k 157
+VALUE KarlNet-TurboCell-TxRate TxRate-158k 158
+VALUE KarlNet-TurboCell-TxRate TxRate-159k 159
+VALUE KarlNet-TurboCell-TxRate TxRate-160k 160
+VALUE KarlNet-TurboCell-TxRate TxRate-161k 161
+VALUE KarlNet-TurboCell-TxRate TxRate-162k 162
+VALUE KarlNet-TurboCell-TxRate TxRate-163k 163
+VALUE KarlNet-TurboCell-TxRate TxRate-164k 164
+VALUE KarlNet-TurboCell-TxRate TxRate-165k 165
+VALUE KarlNet-TurboCell-TxRate TxRate-166k 166
+VALUE KarlNet-TurboCell-TxRate TxRate-167k 167
+VALUE KarlNet-TurboCell-TxRate TxRate-168k 168
+VALUE KarlNet-TurboCell-TxRate TxRate-169k 169
+VALUE KarlNet-TurboCell-TxRate TxRate-170k 170
+VALUE KarlNet-TurboCell-TxRate TxRate-171k 171
+VALUE KarlNet-TurboCell-TxRate TxRate-172k 172
+VALUE KarlNet-TurboCell-TxRate TxRate-173k 173
+VALUE KarlNet-TurboCell-TxRate TxRate-174k 174
+VALUE KarlNet-TurboCell-TxRate TxRate-175k 175
+VALUE KarlNet-TurboCell-TxRate TxRate-176k 176
+VALUE KarlNet-TurboCell-TxRate TxRate-177k 177
+VALUE KarlNet-TurboCell-TxRate TxRate-178k 178
+VALUE KarlNet-TurboCell-TxRate TxRate-179k 179
+VALUE KarlNet-TurboCell-TxRate TxRate-180k 180
+VALUE KarlNet-TurboCell-TxRate TxRate-181k 181
+VALUE KarlNet-TurboCell-TxRate TxRate-182k 182
+VALUE KarlNet-TurboCell-TxRate TxRate-183k 183
+VALUE KarlNet-TurboCell-TxRate TxRate-184k 184
+VALUE KarlNet-TurboCell-TxRate TxRate-185k 185
+VALUE KarlNet-TurboCell-TxRate TxRate-186k 186
+VALUE KarlNet-TurboCell-TxRate TxRate-187k 187
+VALUE KarlNet-TurboCell-TxRate TxRate-188k 188
+VALUE KarlNet-TurboCell-TxRate TxRate-189k 189
+VALUE KarlNet-TurboCell-TxRate TxRate-190k 190
+VALUE KarlNet-TurboCell-TxRate TxRate-191k 191
+VALUE KarlNet-TurboCell-TxRate TxRate-192k 192
+VALUE KarlNet-TurboCell-TxRate TxRate-193k 193
+VALUE KarlNet-TurboCell-TxRate TxRate-194k 194
+VALUE KarlNet-TurboCell-TxRate TxRate-195k 195
+VALUE KarlNet-TurboCell-TxRate TxRate-196k 196
+VALUE KarlNet-TurboCell-TxRate TxRate-197k 197
+VALUE KarlNet-TurboCell-TxRate TxRate-198k 198
+VALUE KarlNet-TurboCell-TxRate TxRate-199k 199
+VALUE KarlNet-TurboCell-TxRate TxRate-200k 200
+VALUE KarlNet-TurboCell-TxRate TxRate-201k 201
+VALUE KarlNet-TurboCell-TxRate TxRate-202k 202
+VALUE KarlNet-TurboCell-TxRate TxRate-203k 203
+VALUE KarlNet-TurboCell-TxRate TxRate-204k 204
+VALUE KarlNet-TurboCell-TxRate TxRate-205k 205
+VALUE KarlNet-TurboCell-TxRate TxRate-206k 206
+VALUE KarlNet-TurboCell-TxRate TxRate-207k 207
+VALUE KarlNet-TurboCell-TxRate TxRate-208k 208
+VALUE KarlNet-TurboCell-TxRate TxRate-209k 209
+VALUE KarlNet-TurboCell-TxRate TxRate-210k 210
+VALUE KarlNet-TurboCell-TxRate TxRate-211k 211
+VALUE KarlNet-TurboCell-TxRate TxRate-212k 212
+VALUE KarlNet-TurboCell-TxRate TxRate-213k 213
+VALUE KarlNet-TurboCell-TxRate TxRate-214k 214
+VALUE KarlNet-TurboCell-TxRate TxRate-215k 215
+VALUE KarlNet-TurboCell-TxRate TxRate-216k 216
+VALUE KarlNet-TurboCell-TxRate TxRate-217k 217
+VALUE KarlNet-TurboCell-TxRate TxRate-218k 218
+VALUE KarlNet-TurboCell-TxRate TxRate-219k 219
+VALUE KarlNet-TurboCell-TxRate TxRate-220k 220
+VALUE KarlNet-TurboCell-TxRate TxRate-221k 221
+VALUE KarlNet-TurboCell-TxRate TxRate-222k 222
+VALUE KarlNet-TurboCell-TxRate TxRate-223k 223
+VALUE KarlNet-TurboCell-TxRate TxRate-224k 224
+VALUE KarlNet-TurboCell-TxRate TxRate-225k 225
+VALUE KarlNet-TurboCell-TxRate TxRate-226k 226
+VALUE KarlNet-TurboCell-TxRate TxRate-227k 227
+VALUE KarlNet-TurboCell-TxRate TxRate-228k 228
+VALUE KarlNet-TurboCell-TxRate TxRate-229k 229
+VALUE KarlNet-TurboCell-TxRate TxRate-230k 230
+VALUE KarlNet-TurboCell-TxRate TxRate-231k 231
+VALUE KarlNet-TurboCell-TxRate TxRate-232k 232
+VALUE KarlNet-TurboCell-TxRate TxRate-233k 233
+VALUE KarlNet-TurboCell-TxRate TxRate-234k 234
+VALUE KarlNet-TurboCell-TxRate TxRate-235k 235
+VALUE KarlNet-TurboCell-TxRate TxRate-236k 236
+VALUE KarlNet-TurboCell-TxRate TxRate-237k 237
+VALUE KarlNet-TurboCell-TxRate TxRate-238k 238
+VALUE KarlNet-TurboCell-TxRate TxRate-239k 239
+VALUE KarlNet-TurboCell-TxRate TxRate-240k 240
+VALUE KarlNet-TurboCell-TxRate TxRate-241k 241
+VALUE KarlNet-TurboCell-TxRate TxRate-242k 242
+VALUE KarlNet-TurboCell-TxRate TxRate-243k 243
+VALUE KarlNet-TurboCell-TxRate TxRate-244k 244
+VALUE KarlNet-TurboCell-TxRate TxRate-245k 245
+VALUE KarlNet-TurboCell-TxRate TxRate-246k 246
+VALUE KarlNet-TurboCell-TxRate TxRate-247k 247
+VALUE KarlNet-TurboCell-TxRate TxRate-248k 248
+VALUE KarlNet-TurboCell-TxRate TxRate-249k 249
+VALUE KarlNet-TurboCell-TxRate TxRate-250k 250
+VALUE KarlNet-TurboCell-TxRate TxRate-251k 251
+VALUE KarlNet-TurboCell-TxRate TxRate-252k 252
+VALUE KarlNet-TurboCell-TxRate TxRate-253k 253
+VALUE KarlNet-TurboCell-TxRate TxRate-254k 254
+VALUE KarlNet-TurboCell-TxRate TxRate-255k 255
+VALUE KarlNet-TurboCell-TxRate TxRate-256k 256
+VALUE KarlNet-TurboCell-TxRate TxRate-257k 257
+VALUE KarlNet-TurboCell-TxRate TxRate-258k 258
+VALUE KarlNet-TurboCell-TxRate TxRate-259k 259
+VALUE KarlNet-TurboCell-TxRate TxRate-260k 260
+VALUE KarlNet-TurboCell-TxRate TxRate-261k 261
+VALUE KarlNet-TurboCell-TxRate TxRate-262k 262
+VALUE KarlNet-TurboCell-TxRate TxRate-263k 263
+VALUE KarlNet-TurboCell-TxRate TxRate-264k 264
+VALUE KarlNet-TurboCell-TxRate TxRate-265k 265
+VALUE KarlNet-TurboCell-TxRate TxRate-266k 266
+VALUE KarlNet-TurboCell-TxRate TxRate-267k 267
+VALUE KarlNet-TurboCell-TxRate TxRate-268k 268
+VALUE KarlNet-TurboCell-TxRate TxRate-269k 269
+VALUE KarlNet-TurboCell-TxRate TxRate-270k 270
+VALUE KarlNet-TurboCell-TxRate TxRate-271k 271
+VALUE KarlNet-TurboCell-TxRate TxRate-272k 272
+VALUE KarlNet-TurboCell-TxRate TxRate-273k 273
+VALUE KarlNet-TurboCell-TxRate TxRate-274k 274
+VALUE KarlNet-TurboCell-TxRate TxRate-275k 275
+VALUE KarlNet-TurboCell-TxRate TxRate-276k 276
+VALUE KarlNet-TurboCell-TxRate TxRate-277k 277
+VALUE KarlNet-TurboCell-TxRate TxRate-278k 278
+VALUE KarlNet-TurboCell-TxRate TxRate-279k 279
+VALUE KarlNet-TurboCell-TxRate TxRate-280k 280
+VALUE KarlNet-TurboCell-TxRate TxRate-281k 281
+VALUE KarlNet-TurboCell-TxRate TxRate-282k 282
+VALUE KarlNet-TurboCell-TxRate TxRate-283k 283
+VALUE KarlNet-TurboCell-TxRate TxRate-284k 284
+VALUE KarlNet-TurboCell-TxRate TxRate-285k 285
+VALUE KarlNet-TurboCell-TxRate TxRate-286k 286
+VALUE KarlNet-TurboCell-TxRate TxRate-287k 287
+VALUE KarlNet-TurboCell-TxRate TxRate-288k 288
+VALUE KarlNet-TurboCell-TxRate TxRate-289k 289
+VALUE KarlNet-TurboCell-TxRate TxRate-290k 290
+VALUE KarlNet-TurboCell-TxRate TxRate-291k 291
+VALUE KarlNet-TurboCell-TxRate TxRate-292k 292
+VALUE KarlNet-TurboCell-TxRate TxRate-293k 293
+VALUE KarlNet-TurboCell-TxRate TxRate-294k 294
+VALUE KarlNet-TurboCell-TxRate TxRate-295k 295
+VALUE KarlNet-TurboCell-TxRate TxRate-296k 296
+VALUE KarlNet-TurboCell-TxRate TxRate-297k 297
+VALUE KarlNet-TurboCell-TxRate TxRate-298k 298
+VALUE KarlNet-TurboCell-TxRate TxRate-299k 299
+VALUE KarlNet-TurboCell-TxRate TxRate-300k 300
+VALUE KarlNet-TurboCell-TxRate TxRate-301k 301
+VALUE KarlNet-TurboCell-TxRate TxRate-302k 302
+VALUE KarlNet-TurboCell-TxRate TxRate-303k 303
+VALUE KarlNet-TurboCell-TxRate TxRate-304k 304
+VALUE KarlNet-TurboCell-TxRate TxRate-305k 305
+VALUE KarlNet-TurboCell-TxRate TxRate-306k 306
+VALUE KarlNet-TurboCell-TxRate TxRate-307k 307
+VALUE KarlNet-TurboCell-TxRate TxRate-308k 308
+VALUE KarlNet-TurboCell-TxRate TxRate-309k 309
+VALUE KarlNet-TurboCell-TxRate TxRate-310k 310
+VALUE KarlNet-TurboCell-TxRate TxRate-311k 311
+VALUE KarlNet-TurboCell-TxRate TxRate-312k 312
+VALUE KarlNet-TurboCell-TxRate TxRate-313k 313
+VALUE KarlNet-TurboCell-TxRate TxRate-314k 314
+VALUE KarlNet-TurboCell-TxRate TxRate-315k 315
+VALUE KarlNet-TurboCell-TxRate TxRate-316k 316
+VALUE KarlNet-TurboCell-TxRate TxRate-317k 317
+VALUE KarlNet-TurboCell-TxRate TxRate-318k 318
+VALUE KarlNet-TurboCell-TxRate TxRate-319k 319
+VALUE KarlNet-TurboCell-TxRate TxRate-320k 320
+VALUE KarlNet-TurboCell-TxRate TxRate-321k 321
+VALUE KarlNet-TurboCell-TxRate TxRate-322k 322
+VALUE KarlNet-TurboCell-TxRate TxRate-323k 323
+VALUE KarlNet-TurboCell-TxRate TxRate-324k 324
+VALUE KarlNet-TurboCell-TxRate TxRate-325k 325
+VALUE KarlNet-TurboCell-TxRate TxRate-326k 326
+VALUE KarlNet-TurboCell-TxRate TxRate-327k 327
+VALUE KarlNet-TurboCell-TxRate TxRate-328k 328
+VALUE KarlNet-TurboCell-TxRate TxRate-329k 329
+VALUE KarlNet-TurboCell-TxRate TxRate-330k 330
+VALUE KarlNet-TurboCell-TxRate TxRate-331k 331
+VALUE KarlNet-TurboCell-TxRate TxRate-332k 332
+VALUE KarlNet-TurboCell-TxRate TxRate-333k 333
+VALUE KarlNet-TurboCell-TxRate TxRate-334k 334
+VALUE KarlNet-TurboCell-TxRate TxRate-335k 335
+VALUE KarlNet-TurboCell-TxRate TxRate-336k 336
+VALUE KarlNet-TurboCell-TxRate TxRate-337k 337
+VALUE KarlNet-TurboCell-TxRate TxRate-338k 338
+VALUE KarlNet-TurboCell-TxRate TxRate-339k 339
+VALUE KarlNet-TurboCell-TxRate TxRate-340k 340
+VALUE KarlNet-TurboCell-TxRate TxRate-341k 341
+VALUE KarlNet-TurboCell-TxRate TxRate-342k 342
+VALUE KarlNet-TurboCell-TxRate TxRate-343k 343
+VALUE KarlNet-TurboCell-TxRate TxRate-344k 344
+VALUE KarlNet-TurboCell-TxRate TxRate-345k 345
+VALUE KarlNet-TurboCell-TxRate TxRate-346k 346
+VALUE KarlNet-TurboCell-TxRate TxRate-347k 347
+VALUE KarlNet-TurboCell-TxRate TxRate-348k 348
+VALUE KarlNet-TurboCell-TxRate TxRate-349k 349
+VALUE KarlNet-TurboCell-TxRate TxRate-350k 350
+VALUE KarlNet-TurboCell-TxRate TxRate-351k 351
+VALUE KarlNet-TurboCell-TxRate TxRate-352k 352
+VALUE KarlNet-TurboCell-TxRate TxRate-353k 353
+VALUE KarlNet-TurboCell-TxRate TxRate-354k 354
+VALUE KarlNet-TurboCell-TxRate TxRate-355k 355
+VALUE KarlNet-TurboCell-TxRate TxRate-356k 356
+VALUE KarlNet-TurboCell-TxRate TxRate-357k 357
+VALUE KarlNet-TurboCell-TxRate TxRate-358k 358
+VALUE KarlNet-TurboCell-TxRate TxRate-359k 359
+VALUE KarlNet-TurboCell-TxRate TxRate-360k 360
+VALUE KarlNet-TurboCell-TxRate TxRate-361k 361
+VALUE KarlNet-TurboCell-TxRate TxRate-362k 362
+VALUE KarlNet-TurboCell-TxRate TxRate-363k 363
+VALUE KarlNet-TurboCell-TxRate TxRate-364k 364
+VALUE KarlNet-TurboCell-TxRate TxRate-365k 365
+VALUE KarlNet-TurboCell-TxRate TxRate-366k 366
+VALUE KarlNet-TurboCell-TxRate TxRate-367k 367
+VALUE KarlNet-TurboCell-TxRate TxRate-368k 368
+VALUE KarlNet-TurboCell-TxRate TxRate-369k 369
+VALUE KarlNet-TurboCell-TxRate TxRate-370k 370
+VALUE KarlNet-TurboCell-TxRate TxRate-371k 371
+VALUE KarlNet-TurboCell-TxRate TxRate-372k 372
+VALUE KarlNet-TurboCell-TxRate TxRate-373k 373
+VALUE KarlNet-TurboCell-TxRate TxRate-374k 374
+VALUE KarlNet-TurboCell-TxRate TxRate-375k 375
+VALUE KarlNet-TurboCell-TxRate TxRate-376k 376
+VALUE KarlNet-TurboCell-TxRate TxRate-377k 377
+VALUE KarlNet-TurboCell-TxRate TxRate-378k 378
+VALUE KarlNet-TurboCell-TxRate TxRate-379k 379
+VALUE KarlNet-TurboCell-TxRate TxRate-380k 380
+VALUE KarlNet-TurboCell-TxRate TxRate-381k 381
+VALUE KarlNet-TurboCell-TxRate TxRate-382k 382
+VALUE KarlNet-TurboCell-TxRate TxRate-383k 383
+VALUE KarlNet-TurboCell-TxRate TxRate-384k 384
+VALUE KarlNet-TurboCell-TxRate TxRate-385k 385
+VALUE KarlNet-TurboCell-TxRate TxRate-386k 386
+VALUE KarlNet-TurboCell-TxRate TxRate-387k 387
+VALUE KarlNet-TurboCell-TxRate TxRate-388k 388
+VALUE KarlNet-TurboCell-TxRate TxRate-389k 389
+VALUE KarlNet-TurboCell-TxRate TxRate-390k 390
+VALUE KarlNet-TurboCell-TxRate TxRate-391k 391
+VALUE KarlNet-TurboCell-TxRate TxRate-392k 392
+VALUE KarlNet-TurboCell-TxRate TxRate-393k 393
+VALUE KarlNet-TurboCell-TxRate TxRate-394k 394
+VALUE KarlNet-TurboCell-TxRate TxRate-395k 395
+VALUE KarlNet-TurboCell-TxRate TxRate-396k 396
+VALUE KarlNet-TurboCell-TxRate TxRate-397k 397
+VALUE KarlNet-TurboCell-TxRate TxRate-398k 398
+VALUE KarlNet-TurboCell-TxRate TxRate-399k 399
+VALUE KarlNet-TurboCell-TxRate TxRate-400k 400
+VALUE KarlNet-TurboCell-TxRate TxRate-401k 401
+VALUE KarlNet-TurboCell-TxRate TxRate-402k 402
+VALUE KarlNet-TurboCell-TxRate TxRate-403k 403
+VALUE KarlNet-TurboCell-TxRate TxRate-404k 404
+VALUE KarlNet-TurboCell-TxRate TxRate-405k 405
+VALUE KarlNet-TurboCell-TxRate TxRate-406k 406
+VALUE KarlNet-TurboCell-TxRate TxRate-407k 407
+VALUE KarlNet-TurboCell-TxRate TxRate-408k 408
+VALUE KarlNet-TurboCell-TxRate TxRate-409k 409
+VALUE KarlNet-TurboCell-TxRate TxRate-410k 410
+VALUE KarlNet-TurboCell-TxRate TxRate-411k 411
+VALUE KarlNet-TurboCell-TxRate TxRate-412k 412
+VALUE KarlNet-TurboCell-TxRate TxRate-413k 413
+VALUE KarlNet-TurboCell-TxRate TxRate-414k 414
+VALUE KarlNet-TurboCell-TxRate TxRate-415k 415
+VALUE KarlNet-TurboCell-TxRate TxRate-416k 416
+VALUE KarlNet-TurboCell-TxRate TxRate-417k 417
+VALUE KarlNet-TurboCell-TxRate TxRate-418k 418
+VALUE KarlNet-TurboCell-TxRate TxRate-419k 419
+VALUE KarlNet-TurboCell-TxRate TxRate-420k 420
+VALUE KarlNet-TurboCell-TxRate TxRate-421k 421
+VALUE KarlNet-TurboCell-TxRate TxRate-422k 422
+VALUE KarlNet-TurboCell-TxRate TxRate-423k 423
+VALUE KarlNet-TurboCell-TxRate TxRate-424k 424
+VALUE KarlNet-TurboCell-TxRate TxRate-425k 425
+VALUE KarlNet-TurboCell-TxRate TxRate-426k 426
+VALUE KarlNet-TurboCell-TxRate TxRate-427k 427
+VALUE KarlNet-TurboCell-TxRate TxRate-428k 428
+VALUE KarlNet-TurboCell-TxRate TxRate-429k 429
+VALUE KarlNet-TurboCell-TxRate TxRate-430k 430
+VALUE KarlNet-TurboCell-TxRate TxRate-431k 431
+VALUE KarlNet-TurboCell-TxRate TxRate-432k 432
+VALUE KarlNet-TurboCell-TxRate TxRate-433k 433
+VALUE KarlNet-TurboCell-TxRate TxRate-434k 434
+VALUE KarlNet-TurboCell-TxRate TxRate-435k 435
+VALUE KarlNet-TurboCell-TxRate TxRate-436k 436
+VALUE KarlNet-TurboCell-TxRate TxRate-437k 437
+VALUE KarlNet-TurboCell-TxRate TxRate-438k 438
+VALUE KarlNet-TurboCell-TxRate TxRate-439k 439
+VALUE KarlNet-TurboCell-TxRate TxRate-440k 440
+VALUE KarlNet-TurboCell-TxRate TxRate-441k 441
+VALUE KarlNet-TurboCell-TxRate TxRate-442k 442
+VALUE KarlNet-TurboCell-TxRate TxRate-443k 443
+VALUE KarlNet-TurboCell-TxRate TxRate-444k 444
+VALUE KarlNet-TurboCell-TxRate TxRate-445k 445
+VALUE KarlNet-TurboCell-TxRate TxRate-446k 446
+VALUE KarlNet-TurboCell-TxRate TxRate-447k 447
+VALUE KarlNet-TurboCell-TxRate TxRate-448k 448
+VALUE KarlNet-TurboCell-TxRate TxRate-449k 449
+VALUE KarlNet-TurboCell-TxRate TxRate-450k 450
+VALUE KarlNet-TurboCell-TxRate TxRate-451k 451
+VALUE KarlNet-TurboCell-TxRate TxRate-452k 452
+VALUE KarlNet-TurboCell-TxRate TxRate-453k 453
+VALUE KarlNet-TurboCell-TxRate TxRate-454k 454
+VALUE KarlNet-TurboCell-TxRate TxRate-455k 455
+VALUE KarlNet-TurboCell-TxRate TxRate-456k 456
+VALUE KarlNet-TurboCell-TxRate TxRate-457k 457
+VALUE KarlNet-TurboCell-TxRate TxRate-458k 458
+VALUE KarlNet-TurboCell-TxRate TxRate-459k 459
+VALUE KarlNet-TurboCell-TxRate TxRate-460k 460
+VALUE KarlNet-TurboCell-TxRate TxRate-461k 461
+VALUE KarlNet-TurboCell-TxRate TxRate-462k 462
+VALUE KarlNet-TurboCell-TxRate TxRate-463k 463
+VALUE KarlNet-TurboCell-TxRate TxRate-464k 464
+VALUE KarlNet-TurboCell-TxRate TxRate-465k 465
+VALUE KarlNet-TurboCell-TxRate TxRate-466k 466
+VALUE KarlNet-TurboCell-TxRate TxRate-467k 467
+VALUE KarlNet-TurboCell-TxRate TxRate-468k 468
+VALUE KarlNet-TurboCell-TxRate TxRate-469k 469
+VALUE KarlNet-TurboCell-TxRate TxRate-470k 470
+VALUE KarlNet-TurboCell-TxRate TxRate-471k 471
+VALUE KarlNet-TurboCell-TxRate TxRate-472k 472
+VALUE KarlNet-TurboCell-TxRate TxRate-473k 473
+VALUE KarlNet-TurboCell-TxRate TxRate-474k 474
+VALUE KarlNet-TurboCell-TxRate TxRate-475k 475
+VALUE KarlNet-TurboCell-TxRate TxRate-476k 476
+VALUE KarlNet-TurboCell-TxRate TxRate-477k 477
+VALUE KarlNet-TurboCell-TxRate TxRate-478k 478
+VALUE KarlNet-TurboCell-TxRate TxRate-479k 479
+VALUE KarlNet-TurboCell-TxRate TxRate-480k 480
+VALUE KarlNet-TurboCell-TxRate TxRate-481k 481
+VALUE KarlNet-TurboCell-TxRate TxRate-482k 482
+VALUE KarlNet-TurboCell-TxRate TxRate-483k 483
+VALUE KarlNet-TurboCell-TxRate TxRate-484k 484
+VALUE KarlNet-TurboCell-TxRate TxRate-485k 485
+VALUE KarlNet-TurboCell-TxRate TxRate-486k 486
+VALUE KarlNet-TurboCell-TxRate TxRate-487k 487
+VALUE KarlNet-TurboCell-TxRate TxRate-488k 488
+VALUE KarlNet-TurboCell-TxRate TxRate-489k 489
+VALUE KarlNet-TurboCell-TxRate TxRate-490k 490
+VALUE KarlNet-TurboCell-TxRate TxRate-491k 491
+VALUE KarlNet-TurboCell-TxRate TxRate-492k 492
+VALUE KarlNet-TurboCell-TxRate TxRate-493k 493
+VALUE KarlNet-TurboCell-TxRate TxRate-494k 494
+VALUE KarlNet-TurboCell-TxRate TxRate-495k 495
+VALUE KarlNet-TurboCell-TxRate TxRate-496k 496
+VALUE KarlNet-TurboCell-TxRate TxRate-497k 497
+VALUE KarlNet-TurboCell-TxRate TxRate-498k 498
+VALUE KarlNet-TurboCell-TxRate TxRate-499k 499
+VALUE KarlNet-TurboCell-TxRate TxRate-500k 500
+VALUE KarlNet-TurboCell-TxRate TxRate-501k 501
+VALUE KarlNet-TurboCell-TxRate TxRate-502k 502
+VALUE KarlNet-TurboCell-TxRate TxRate-503k 503
+VALUE KarlNet-TurboCell-TxRate TxRate-504k 504
+VALUE KarlNet-TurboCell-TxRate TxRate-505k 505
+VALUE KarlNet-TurboCell-TxRate TxRate-506k 506
+VALUE KarlNet-TurboCell-TxRate TxRate-507k 507
+VALUE KarlNet-TurboCell-TxRate TxRate-508k 508
+VALUE KarlNet-TurboCell-TxRate TxRate-509k 509
+VALUE KarlNet-TurboCell-TxRate TxRate-510k 510
+VALUE KarlNet-TurboCell-TxRate TxRate-511k 511
+VALUE KarlNet-TurboCell-TxRate TxRate-512k 512
+VALUE KarlNet-TurboCell-TxRate TxRate-513k 513
+VALUE KarlNet-TurboCell-TxRate TxRate-514k 514
+VALUE KarlNet-TurboCell-TxRate TxRate-515k 515
+VALUE KarlNet-TurboCell-TxRate TxRate-516k 516
+VALUE KarlNet-TurboCell-TxRate TxRate-517k 517
+VALUE KarlNet-TurboCell-TxRate TxRate-518k 518
+VALUE KarlNet-TurboCell-TxRate TxRate-519k 519
+VALUE KarlNet-TurboCell-TxRate TxRate-520k 520
+VALUE KarlNet-TurboCell-TxRate TxRate-521k 521
+VALUE KarlNet-TurboCell-TxRate TxRate-522k 522
+VALUE KarlNet-TurboCell-TxRate TxRate-523k 523
+VALUE KarlNet-TurboCell-TxRate TxRate-524k 524
+VALUE KarlNet-TurboCell-TxRate TxRate-525k 525
+VALUE KarlNet-TurboCell-TxRate TxRate-526k 526
+VALUE KarlNet-TurboCell-TxRate TxRate-527k 527
+VALUE KarlNet-TurboCell-TxRate TxRate-528k 528
+VALUE KarlNet-TurboCell-TxRate TxRate-529k 529
+VALUE KarlNet-TurboCell-TxRate TxRate-530k 530
+VALUE KarlNet-TurboCell-TxRate TxRate-531k 531
+VALUE KarlNet-TurboCell-TxRate TxRate-532k 532
+VALUE KarlNet-TurboCell-TxRate TxRate-533k 533
+VALUE KarlNet-TurboCell-TxRate TxRate-534k 534
+VALUE KarlNet-TurboCell-TxRate TxRate-535k 535
+VALUE KarlNet-TurboCell-TxRate TxRate-536k 536
+VALUE KarlNet-TurboCell-TxRate TxRate-537k 537
+VALUE KarlNet-TurboCell-TxRate TxRate-538k 538
+VALUE KarlNet-TurboCell-TxRate TxRate-539k 539
+VALUE KarlNet-TurboCell-TxRate TxRate-540k 540
+VALUE KarlNet-TurboCell-TxRate TxRate-541k 541
+VALUE KarlNet-TurboCell-TxRate TxRate-542k 542
+VALUE KarlNet-TurboCell-TxRate TxRate-543k 543
+VALUE KarlNet-TurboCell-TxRate TxRate-544k 544
+VALUE KarlNet-TurboCell-TxRate TxRate-545k 545
+VALUE KarlNet-TurboCell-TxRate TxRate-546k 546
+VALUE KarlNet-TurboCell-TxRate TxRate-547k 547
+VALUE KarlNet-TurboCell-TxRate TxRate-548k 548
+VALUE KarlNet-TurboCell-TxRate TxRate-549k 549
+VALUE KarlNet-TurboCell-TxRate TxRate-550k 550
+VALUE KarlNet-TurboCell-TxRate TxRate-551k 551
+VALUE KarlNet-TurboCell-TxRate TxRate-552k 552
+VALUE KarlNet-TurboCell-TxRate TxRate-553k 553
+VALUE KarlNet-TurboCell-TxRate TxRate-554k 554
+VALUE KarlNet-TurboCell-TxRate TxRate-555k 555
+VALUE KarlNet-TurboCell-TxRate TxRate-556k 556
+VALUE KarlNet-TurboCell-TxRate TxRate-557k 557
+VALUE KarlNet-TurboCell-TxRate TxRate-558k 558
+VALUE KarlNet-TurboCell-TxRate TxRate-559k 559
+VALUE KarlNet-TurboCell-TxRate TxRate-560k 560
+VALUE KarlNet-TurboCell-TxRate TxRate-561k 561
+VALUE KarlNet-TurboCell-TxRate TxRate-562k 562
+VALUE KarlNet-TurboCell-TxRate TxRate-563k 563
+VALUE KarlNet-TurboCell-TxRate TxRate-564k 564
+VALUE KarlNet-TurboCell-TxRate TxRate-565k 565
+VALUE KarlNet-TurboCell-TxRate TxRate-566k 566
+VALUE KarlNet-TurboCell-TxRate TxRate-567k 567
+VALUE KarlNet-TurboCell-TxRate TxRate-568k 568
+VALUE KarlNet-TurboCell-TxRate TxRate-569k 569
+VALUE KarlNet-TurboCell-TxRate TxRate-570k 570
+VALUE KarlNet-TurboCell-TxRate TxRate-571k 571
+VALUE KarlNet-TurboCell-TxRate TxRate-572k 572
+VALUE KarlNet-TurboCell-TxRate TxRate-573k 573
+VALUE KarlNet-TurboCell-TxRate TxRate-574k 574
+VALUE KarlNet-TurboCell-TxRate TxRate-575k 575
+VALUE KarlNet-TurboCell-TxRate TxRate-576k 576
+VALUE KarlNet-TurboCell-TxRate TxRate-577k 577
+VALUE KarlNet-TurboCell-TxRate TxRate-578k 578
+VALUE KarlNet-TurboCell-TxRate TxRate-579k 579
+VALUE KarlNet-TurboCell-TxRate TxRate-580k 580
+VALUE KarlNet-TurboCell-TxRate TxRate-581k 581
+VALUE KarlNet-TurboCell-TxRate TxRate-582k 582
+VALUE KarlNet-TurboCell-TxRate TxRate-583k 583
+VALUE KarlNet-TurboCell-TxRate TxRate-584k 584
+VALUE KarlNet-TurboCell-TxRate TxRate-585k 585
+VALUE KarlNet-TurboCell-TxRate TxRate-586k 586
+VALUE KarlNet-TurboCell-TxRate TxRate-587k 587
+VALUE KarlNet-TurboCell-TxRate TxRate-588k 588
+VALUE KarlNet-TurboCell-TxRate TxRate-589k 589
+VALUE KarlNet-TurboCell-TxRate TxRate-590k 590
+VALUE KarlNet-TurboCell-TxRate TxRate-591k 591
+VALUE KarlNet-TurboCell-TxRate TxRate-592k 592
+VALUE KarlNet-TurboCell-TxRate TxRate-593k 593
+VALUE KarlNet-TurboCell-TxRate TxRate-594k 594
+VALUE KarlNet-TurboCell-TxRate TxRate-595k 595
+VALUE KarlNet-TurboCell-TxRate TxRate-596k 596
+VALUE KarlNet-TurboCell-TxRate TxRate-597k 597
+VALUE KarlNet-TurboCell-TxRate TxRate-598k 598
+VALUE KarlNet-TurboCell-TxRate TxRate-599k 599
+VALUE KarlNet-TurboCell-TxRate TxRate-600k 600
+VALUE KarlNet-TurboCell-TxRate TxRate-601k 601
+VALUE KarlNet-TurboCell-TxRate TxRate-602k 602
+VALUE KarlNet-TurboCell-TxRate TxRate-603k 603
+VALUE KarlNet-TurboCell-TxRate TxRate-604k 604
+VALUE KarlNet-TurboCell-TxRate TxRate-605k 605
+VALUE KarlNet-TurboCell-TxRate TxRate-606k 606
+VALUE KarlNet-TurboCell-TxRate TxRate-607k 607
+VALUE KarlNet-TurboCell-TxRate TxRate-608k 608
+VALUE KarlNet-TurboCell-TxRate TxRate-609k 609
+VALUE KarlNet-TurboCell-TxRate TxRate-610k 610
+VALUE KarlNet-TurboCell-TxRate TxRate-611k 611
+VALUE KarlNet-TurboCell-TxRate TxRate-612k 612
+VALUE KarlNet-TurboCell-TxRate TxRate-613k 613
+VALUE KarlNet-TurboCell-TxRate TxRate-614k 614
+VALUE KarlNet-TurboCell-TxRate TxRate-615k 615
+VALUE KarlNet-TurboCell-TxRate TxRate-616k 616
+VALUE KarlNet-TurboCell-TxRate TxRate-617k 617
+VALUE KarlNet-TurboCell-TxRate TxRate-618k 618
+VALUE KarlNet-TurboCell-TxRate TxRate-619k 619
+VALUE KarlNet-TurboCell-TxRate TxRate-620k 620
+VALUE KarlNet-TurboCell-TxRate TxRate-621k 621
+VALUE KarlNet-TurboCell-TxRate TxRate-622k 622
+VALUE KarlNet-TurboCell-TxRate TxRate-623k 623
+VALUE KarlNet-TurboCell-TxRate TxRate-624k 624
+VALUE KarlNet-TurboCell-TxRate TxRate-625k 625
+VALUE KarlNet-TurboCell-TxRate TxRate-626k 626
+VALUE KarlNet-TurboCell-TxRate TxRate-627k 627
+VALUE KarlNet-TurboCell-TxRate TxRate-628k 628
+VALUE KarlNet-TurboCell-TxRate TxRate-629k 629
+VALUE KarlNet-TurboCell-TxRate TxRate-630k 630
+VALUE KarlNet-TurboCell-TxRate TxRate-631k 631
+VALUE KarlNet-TurboCell-TxRate TxRate-632k 632
+VALUE KarlNet-TurboCell-TxRate TxRate-633k 633
+VALUE KarlNet-TurboCell-TxRate TxRate-634k 634
+VALUE KarlNet-TurboCell-TxRate TxRate-635k 635
+VALUE KarlNet-TurboCell-TxRate TxRate-636k 636
+VALUE KarlNet-TurboCell-TxRate TxRate-637k 637
+VALUE KarlNet-TurboCell-TxRate TxRate-638k 638
+VALUE KarlNet-TurboCell-TxRate TxRate-639k 639
+VALUE KarlNet-TurboCell-TxRate TxRate-640k 640
+VALUE KarlNet-TurboCell-TxRate TxRate-641k 641
+VALUE KarlNet-TurboCell-TxRate TxRate-642k 642
+VALUE KarlNet-TurboCell-TxRate TxRate-643k 643
+VALUE KarlNet-TurboCell-TxRate TxRate-644k 644
+VALUE KarlNet-TurboCell-TxRate TxRate-645k 645
+VALUE KarlNet-TurboCell-TxRate TxRate-646k 646
+VALUE KarlNet-TurboCell-TxRate TxRate-647k 647
+VALUE KarlNet-TurboCell-TxRate TxRate-648k 648
+VALUE KarlNet-TurboCell-TxRate TxRate-649k 649
+VALUE KarlNet-TurboCell-TxRate TxRate-650k 650
+VALUE KarlNet-TurboCell-TxRate TxRate-651k 651
+VALUE KarlNet-TurboCell-TxRate TxRate-652k 652
+VALUE KarlNet-TurboCell-TxRate TxRate-653k 653
+VALUE KarlNet-TurboCell-TxRate TxRate-654k 654
+VALUE KarlNet-TurboCell-TxRate TxRate-655k 655
+VALUE KarlNet-TurboCell-TxRate TxRate-656k 656
+VALUE KarlNet-TurboCell-TxRate TxRate-657k 657
+VALUE KarlNet-TurboCell-TxRate TxRate-658k 658
+VALUE KarlNet-TurboCell-TxRate TxRate-659k 659
+VALUE KarlNet-TurboCell-TxRate TxRate-660k 660
+VALUE KarlNet-TurboCell-TxRate TxRate-661k 661
+VALUE KarlNet-TurboCell-TxRate TxRate-662k 662
+VALUE KarlNet-TurboCell-TxRate TxRate-663k 663
+VALUE KarlNet-TurboCell-TxRate TxRate-664k 664
+VALUE KarlNet-TurboCell-TxRate TxRate-665k 665
+VALUE KarlNet-TurboCell-TxRate TxRate-666k 666
+VALUE KarlNet-TurboCell-TxRate TxRate-667k 667
+VALUE KarlNet-TurboCell-TxRate TxRate-668k 668
+VALUE KarlNet-TurboCell-TxRate TxRate-669k 669
+VALUE KarlNet-TurboCell-TxRate TxRate-670k 670
+VALUE KarlNet-TurboCell-TxRate TxRate-671k 671
+VALUE KarlNet-TurboCell-TxRate TxRate-672k 672
+VALUE KarlNet-TurboCell-TxRate TxRate-673k 673
+VALUE KarlNet-TurboCell-TxRate TxRate-674k 674
+VALUE KarlNet-TurboCell-TxRate TxRate-675k 675
+VALUE KarlNet-TurboCell-TxRate TxRate-676k 676
+VALUE KarlNet-TurboCell-TxRate TxRate-677k 677
+VALUE KarlNet-TurboCell-TxRate TxRate-678k 678
+VALUE KarlNet-TurboCell-TxRate TxRate-679k 679
+VALUE KarlNet-TurboCell-TxRate TxRate-680k 680
+VALUE KarlNet-TurboCell-TxRate TxRate-681k 681
+VALUE KarlNet-TurboCell-TxRate TxRate-682k 682
+VALUE KarlNet-TurboCell-TxRate TxRate-683k 683
+VALUE KarlNet-TurboCell-TxRate TxRate-684k 684
+VALUE KarlNet-TurboCell-TxRate TxRate-685k 685
+VALUE KarlNet-TurboCell-TxRate TxRate-686k 686
+VALUE KarlNet-TurboCell-TxRate TxRate-687k 687
+VALUE KarlNet-TurboCell-TxRate TxRate-688k 688
+VALUE KarlNet-TurboCell-TxRate TxRate-689k 689
+VALUE KarlNet-TurboCell-TxRate TxRate-690k 690
+VALUE KarlNet-TurboCell-TxRate TxRate-691k 691
+VALUE KarlNet-TurboCell-TxRate TxRate-692k 692
+VALUE KarlNet-TurboCell-TxRate TxRate-693k 693
+VALUE KarlNet-TurboCell-TxRate TxRate-694k 694
+VALUE KarlNet-TurboCell-TxRate TxRate-695k 695
+VALUE KarlNet-TurboCell-TxRate TxRate-696k 696
+VALUE KarlNet-TurboCell-TxRate TxRate-697k 697
+VALUE KarlNet-TurboCell-TxRate TxRate-698k 698
+VALUE KarlNet-TurboCell-TxRate TxRate-699k 699
+VALUE KarlNet-TurboCell-TxRate TxRate-700k 700
+VALUE KarlNet-TurboCell-TxRate TxRate-701k 701
+VALUE KarlNet-TurboCell-TxRate TxRate-702k 702
+VALUE KarlNet-TurboCell-TxRate TxRate-703k 703
+VALUE KarlNet-TurboCell-TxRate TxRate-704k 704
+VALUE KarlNet-TurboCell-TxRate TxRate-705k 705
+VALUE KarlNet-TurboCell-TxRate TxRate-706k 706
+VALUE KarlNet-TurboCell-TxRate TxRate-707k 707
+VALUE KarlNet-TurboCell-TxRate TxRate-708k 708
+VALUE KarlNet-TurboCell-TxRate TxRate-709k 709
+VALUE KarlNet-TurboCell-TxRate TxRate-710k 710
+VALUE KarlNet-TurboCell-TxRate TxRate-711k 711
+VALUE KarlNet-TurboCell-TxRate TxRate-712k 712
+VALUE KarlNet-TurboCell-TxRate TxRate-713k 713
+VALUE KarlNet-TurboCell-TxRate TxRate-714k 714
+VALUE KarlNet-TurboCell-TxRate TxRate-715k 715
+VALUE KarlNet-TurboCell-TxRate TxRate-716k 716
+VALUE KarlNet-TurboCell-TxRate TxRate-717k 717
+VALUE KarlNet-TurboCell-TxRate TxRate-718k 718
+VALUE KarlNet-TurboCell-TxRate TxRate-719k 719
+VALUE KarlNet-TurboCell-TxRate TxRate-720k 720
+VALUE KarlNet-TurboCell-TxRate TxRate-721k 721
+VALUE KarlNet-TurboCell-TxRate TxRate-722k 722
+VALUE KarlNet-TurboCell-TxRate TxRate-723k 723
+VALUE KarlNet-TurboCell-TxRate TxRate-724k 724
+VALUE KarlNet-TurboCell-TxRate TxRate-725k 725
+VALUE KarlNet-TurboCell-TxRate TxRate-726k 726
+VALUE KarlNet-TurboCell-TxRate TxRate-727k 727
+VALUE KarlNet-TurboCell-TxRate TxRate-728k 728
+VALUE KarlNet-TurboCell-TxRate TxRate-729k 729
+VALUE KarlNet-TurboCell-TxRate TxRate-730k 730
+VALUE KarlNet-TurboCell-TxRate TxRate-731k 731
+VALUE KarlNet-TurboCell-TxRate TxRate-732k 732
+VALUE KarlNet-TurboCell-TxRate TxRate-733k 733
+VALUE KarlNet-TurboCell-TxRate TxRate-734k 734
+VALUE KarlNet-TurboCell-TxRate TxRate-735k 735
+VALUE KarlNet-TurboCell-TxRate TxRate-736k 736
+VALUE KarlNet-TurboCell-TxRate TxRate-737k 737
+VALUE KarlNet-TurboCell-TxRate TxRate-738k 738
+VALUE KarlNet-TurboCell-TxRate TxRate-739k 739
+VALUE KarlNet-TurboCell-TxRate TxRate-740k 740
+VALUE KarlNet-TurboCell-TxRate TxRate-741k 741
+VALUE KarlNet-TurboCell-TxRate TxRate-742k 742
+VALUE KarlNet-TurboCell-TxRate TxRate-743k 743
+VALUE KarlNet-TurboCell-TxRate TxRate-744k 744
+VALUE KarlNet-TurboCell-TxRate TxRate-745k 745
+VALUE KarlNet-TurboCell-TxRate TxRate-746k 746
+VALUE KarlNet-TurboCell-TxRate TxRate-747k 747
+VALUE KarlNet-TurboCell-TxRate TxRate-748k 748
+VALUE KarlNet-TurboCell-TxRate TxRate-749k 749
+VALUE KarlNet-TurboCell-TxRate TxRate-750k 750
+VALUE KarlNet-TurboCell-TxRate TxRate-751k 751
+VALUE KarlNet-TurboCell-TxRate TxRate-752k 752
+VALUE KarlNet-TurboCell-TxRate TxRate-753k 753
+VALUE KarlNet-TurboCell-TxRate TxRate-754k 754
+VALUE KarlNet-TurboCell-TxRate TxRate-755k 755
+VALUE KarlNet-TurboCell-TxRate TxRate-756k 756
+VALUE KarlNet-TurboCell-TxRate TxRate-757k 757
+VALUE KarlNet-TurboCell-TxRate TxRate-758k 758
+VALUE KarlNet-TurboCell-TxRate TxRate-759k 759
+VALUE KarlNet-TurboCell-TxRate TxRate-760k 760
+VALUE KarlNet-TurboCell-TxRate TxRate-761k 761
+VALUE KarlNet-TurboCell-TxRate TxRate-762k 762
+VALUE KarlNet-TurboCell-TxRate TxRate-763k 763
+VALUE KarlNet-TurboCell-TxRate TxRate-764k 764
+VALUE KarlNet-TurboCell-TxRate TxRate-765k 765
+VALUE KarlNet-TurboCell-TxRate TxRate-766k 766
+VALUE KarlNet-TurboCell-TxRate TxRate-767k 767
+VALUE KarlNet-TurboCell-TxRate TxRate-768k 768
+VALUE KarlNet-TurboCell-TxRate TxRate-769k 769
+VALUE KarlNet-TurboCell-TxRate TxRate-770k 770
+VALUE KarlNet-TurboCell-TxRate TxRate-771k 771
+VALUE KarlNet-TurboCell-TxRate TxRate-772k 772
+VALUE KarlNet-TurboCell-TxRate TxRate-773k 773
+VALUE KarlNet-TurboCell-TxRate TxRate-774k 774
+VALUE KarlNet-TurboCell-TxRate TxRate-775k 775
+VALUE KarlNet-TurboCell-TxRate TxRate-776k 776
+VALUE KarlNet-TurboCell-TxRate TxRate-777k 777
+VALUE KarlNet-TurboCell-TxRate TxRate-778k 778
+VALUE KarlNet-TurboCell-TxRate TxRate-779k 779
+VALUE KarlNet-TurboCell-TxRate TxRate-780k 780
+VALUE KarlNet-TurboCell-TxRate TxRate-781k 781
+VALUE KarlNet-TurboCell-TxRate TxRate-782k 782
+VALUE KarlNet-TurboCell-TxRate TxRate-783k 783
+VALUE KarlNet-TurboCell-TxRate TxRate-784k 784
+VALUE KarlNet-TurboCell-TxRate TxRate-785k 785
+VALUE KarlNet-TurboCell-TxRate TxRate-786k 786
+VALUE KarlNet-TurboCell-TxRate TxRate-787k 787
+VALUE KarlNet-TurboCell-TxRate TxRate-788k 788
+VALUE KarlNet-TurboCell-TxRate TxRate-789k 789
+VALUE KarlNet-TurboCell-TxRate TxRate-790k 790
+VALUE KarlNet-TurboCell-TxRate TxRate-791k 791
+VALUE KarlNet-TurboCell-TxRate TxRate-792k 792
+VALUE KarlNet-TurboCell-TxRate TxRate-793k 793
+VALUE KarlNet-TurboCell-TxRate TxRate-794k 794
+VALUE KarlNet-TurboCell-TxRate TxRate-795k 795
+VALUE KarlNet-TurboCell-TxRate TxRate-796k 796
+VALUE KarlNet-TurboCell-TxRate TxRate-797k 797
+VALUE KarlNet-TurboCell-TxRate TxRate-798k 798
+VALUE KarlNet-TurboCell-TxRate TxRate-799k 799
+VALUE KarlNet-TurboCell-TxRate TxRate-800k 800
+VALUE KarlNet-TurboCell-TxRate TxRate-801k 801
+VALUE KarlNet-TurboCell-TxRate TxRate-802k 802
+VALUE KarlNet-TurboCell-TxRate TxRate-803k 803
+VALUE KarlNet-TurboCell-TxRate TxRate-804k 804
+VALUE KarlNet-TurboCell-TxRate TxRate-805k 805
+VALUE KarlNet-TurboCell-TxRate TxRate-806k 806
+VALUE KarlNet-TurboCell-TxRate TxRate-807k 807
+VALUE KarlNet-TurboCell-TxRate TxRate-808k 808
+VALUE KarlNet-TurboCell-TxRate TxRate-809k 809
+VALUE KarlNet-TurboCell-TxRate TxRate-810k 810
+VALUE KarlNet-TurboCell-TxRate TxRate-811k 811
+VALUE KarlNet-TurboCell-TxRate TxRate-812k 812
+VALUE KarlNet-TurboCell-TxRate TxRate-813k 813
+VALUE KarlNet-TurboCell-TxRate TxRate-814k 814
+VALUE KarlNet-TurboCell-TxRate TxRate-815k 815
+VALUE KarlNet-TurboCell-TxRate TxRate-816k 816
+VALUE KarlNet-TurboCell-TxRate TxRate-817k 817
+VALUE KarlNet-TurboCell-TxRate TxRate-818k 818
+VALUE KarlNet-TurboCell-TxRate TxRate-819k 819
+VALUE KarlNet-TurboCell-TxRate TxRate-820k 820
+VALUE KarlNet-TurboCell-TxRate TxRate-821k 821
+VALUE KarlNet-TurboCell-TxRate TxRate-822k 822
+VALUE KarlNet-TurboCell-TxRate TxRate-823k 823
+VALUE KarlNet-TurboCell-TxRate TxRate-824k 824
+VALUE KarlNet-TurboCell-TxRate TxRate-825k 825
+VALUE KarlNet-TurboCell-TxRate TxRate-826k 826
+VALUE KarlNet-TurboCell-TxRate TxRate-827k 827
+VALUE KarlNet-TurboCell-TxRate TxRate-828k 828
+VALUE KarlNet-TurboCell-TxRate TxRate-829k 829
+VALUE KarlNet-TurboCell-TxRate TxRate-830k 830
+VALUE KarlNet-TurboCell-TxRate TxRate-831k 831
+VALUE KarlNet-TurboCell-TxRate TxRate-832k 832
+VALUE KarlNet-TurboCell-TxRate TxRate-833k 833
+VALUE KarlNet-TurboCell-TxRate TxRate-834k 834
+VALUE KarlNet-TurboCell-TxRate TxRate-835k 835
+VALUE KarlNet-TurboCell-TxRate TxRate-836k 836
+VALUE KarlNet-TurboCell-TxRate TxRate-837k 837
+VALUE KarlNet-TurboCell-TxRate TxRate-838k 838
+VALUE KarlNet-TurboCell-TxRate TxRate-839k 839
+VALUE KarlNet-TurboCell-TxRate TxRate-840k 840
+VALUE KarlNet-TurboCell-TxRate TxRate-841k 841
+VALUE KarlNet-TurboCell-TxRate TxRate-842k 842
+VALUE KarlNet-TurboCell-TxRate TxRate-843k 843
+VALUE KarlNet-TurboCell-TxRate TxRate-844k 844
+VALUE KarlNet-TurboCell-TxRate TxRate-845k 845
+VALUE KarlNet-TurboCell-TxRate TxRate-846k 846
+VALUE KarlNet-TurboCell-TxRate TxRate-847k 847
+VALUE KarlNet-TurboCell-TxRate TxRate-848k 848
+VALUE KarlNet-TurboCell-TxRate TxRate-849k 849
+VALUE KarlNet-TurboCell-TxRate TxRate-850k 850
+VALUE KarlNet-TurboCell-TxRate TxRate-851k 851
+VALUE KarlNet-TurboCell-TxRate TxRate-852k 852
+VALUE KarlNet-TurboCell-TxRate TxRate-853k 853
+VALUE KarlNet-TurboCell-TxRate TxRate-854k 854
+VALUE KarlNet-TurboCell-TxRate TxRate-855k 855
+VALUE KarlNet-TurboCell-TxRate TxRate-856k 856
+VALUE KarlNet-TurboCell-TxRate TxRate-857k 857
+VALUE KarlNet-TurboCell-TxRate TxRate-858k 858
+VALUE KarlNet-TurboCell-TxRate TxRate-859k 859
+VALUE KarlNet-TurboCell-TxRate TxRate-860k 860
+VALUE KarlNet-TurboCell-TxRate TxRate-861k 861
+VALUE KarlNet-TurboCell-TxRate TxRate-862k 862
+VALUE KarlNet-TurboCell-TxRate TxRate-863k 863
+VALUE KarlNet-TurboCell-TxRate TxRate-864k 864
+VALUE KarlNet-TurboCell-TxRate TxRate-865k 865
+VALUE KarlNet-TurboCell-TxRate TxRate-866k 866
+VALUE KarlNet-TurboCell-TxRate TxRate-867k 867
+VALUE KarlNet-TurboCell-TxRate TxRate-868k 868
+VALUE KarlNet-TurboCell-TxRate TxRate-869k 869
+VALUE KarlNet-TurboCell-TxRate TxRate-870k 870
+VALUE KarlNet-TurboCell-TxRate TxRate-871k 871
+VALUE KarlNet-TurboCell-TxRate TxRate-872k 872
+VALUE KarlNet-TurboCell-TxRate TxRate-873k 873
+VALUE KarlNet-TurboCell-TxRate TxRate-874k 874
+VALUE KarlNet-TurboCell-TxRate TxRate-875k 875
+VALUE KarlNet-TurboCell-TxRate TxRate-876k 876
+VALUE KarlNet-TurboCell-TxRate TxRate-877k 877
+VALUE KarlNet-TurboCell-TxRate TxRate-878k 878
+VALUE KarlNet-TurboCell-TxRate TxRate-879k 879
+VALUE KarlNet-TurboCell-TxRate TxRate-880k 880
+VALUE KarlNet-TurboCell-TxRate TxRate-881k 881
+VALUE KarlNet-TurboCell-TxRate TxRate-882k 882
+VALUE KarlNet-TurboCell-TxRate TxRate-883k 883
+VALUE KarlNet-TurboCell-TxRate TxRate-884k 884
+VALUE KarlNet-TurboCell-TxRate TxRate-885k 885
+VALUE KarlNet-TurboCell-TxRate TxRate-886k 886
+VALUE KarlNet-TurboCell-TxRate TxRate-887k 887
+VALUE KarlNet-TurboCell-TxRate TxRate-888k 888
+VALUE KarlNet-TurboCell-TxRate TxRate-889k 889
+VALUE KarlNet-TurboCell-TxRate TxRate-890k 890
+VALUE KarlNet-TurboCell-TxRate TxRate-891k 891
+VALUE KarlNet-TurboCell-TxRate TxRate-892k 892
+VALUE KarlNet-TurboCell-TxRate TxRate-893k 893
+VALUE KarlNet-TurboCell-TxRate TxRate-894k 894
+VALUE KarlNet-TurboCell-TxRate TxRate-895k 895
+VALUE KarlNet-TurboCell-TxRate TxRate-896k 896
+VALUE KarlNet-TurboCell-TxRate TxRate-897k 897
+VALUE KarlNet-TurboCell-TxRate TxRate-898k 898
+VALUE KarlNet-TurboCell-TxRate TxRate-899k 899
+VALUE KarlNet-TurboCell-TxRate TxRate-900k 900
+VALUE KarlNet-TurboCell-TxRate TxRate-901k 901
+VALUE KarlNet-TurboCell-TxRate TxRate-902k 902
+VALUE KarlNet-TurboCell-TxRate TxRate-903k 903
+VALUE KarlNet-TurboCell-TxRate TxRate-904k 904
+VALUE KarlNet-TurboCell-TxRate TxRate-905k 905
+VALUE KarlNet-TurboCell-TxRate TxRate-906k 906
+VALUE KarlNet-TurboCell-TxRate TxRate-907k 907
+VALUE KarlNet-TurboCell-TxRate TxRate-908k 908
+VALUE KarlNet-TurboCell-TxRate TxRate-909k 909
+VALUE KarlNet-TurboCell-TxRate TxRate-910k 910
+VALUE KarlNet-TurboCell-TxRate TxRate-911k 911
+VALUE KarlNet-TurboCell-TxRate TxRate-912k 912
+VALUE KarlNet-TurboCell-TxRate TxRate-913k 913
+VALUE KarlNet-TurboCell-TxRate TxRate-914k 914
+VALUE KarlNet-TurboCell-TxRate TxRate-915k 915
+VALUE KarlNet-TurboCell-TxRate TxRate-916k 916
+VALUE KarlNet-TurboCell-TxRate TxRate-917k 917
+VALUE KarlNet-TurboCell-TxRate TxRate-918k 918
+VALUE KarlNet-TurboCell-TxRate TxRate-919k 919
+VALUE KarlNet-TurboCell-TxRate TxRate-920k 920
+VALUE KarlNet-TurboCell-TxRate TxRate-921k 921
+VALUE KarlNet-TurboCell-TxRate TxRate-922k 922
+VALUE KarlNet-TurboCell-TxRate TxRate-923k 923
+VALUE KarlNet-TurboCell-TxRate TxRate-924k 924
+VALUE KarlNet-TurboCell-TxRate TxRate-925k 925
+VALUE KarlNet-TurboCell-TxRate TxRate-926k 926
+VALUE KarlNet-TurboCell-TxRate TxRate-927k 927
+VALUE KarlNet-TurboCell-TxRate TxRate-928k 928
+VALUE KarlNet-TurboCell-TxRate TxRate-929k 929
+VALUE KarlNet-TurboCell-TxRate TxRate-930k 930
+VALUE KarlNet-TurboCell-TxRate TxRate-931k 931
+VALUE KarlNet-TurboCell-TxRate TxRate-932k 932
+VALUE KarlNet-TurboCell-TxRate TxRate-933k 933
+VALUE KarlNet-TurboCell-TxRate TxRate-934k 934
+VALUE KarlNet-TurboCell-TxRate TxRate-935k 935
+VALUE KarlNet-TurboCell-TxRate TxRate-936k 936
+VALUE KarlNet-TurboCell-TxRate TxRate-937k 937
+VALUE KarlNet-TurboCell-TxRate TxRate-938k 938
+VALUE KarlNet-TurboCell-TxRate TxRate-939k 939
+VALUE KarlNet-TurboCell-TxRate TxRate-940k 940
+VALUE KarlNet-TurboCell-TxRate TxRate-941k 941
+VALUE KarlNet-TurboCell-TxRate TxRate-942k 942
+VALUE KarlNet-TurboCell-TxRate TxRate-943k 943
+VALUE KarlNet-TurboCell-TxRate TxRate-944k 944
+VALUE KarlNet-TurboCell-TxRate TxRate-945k 945
+VALUE KarlNet-TurboCell-TxRate TxRate-946k 946
+VALUE KarlNet-TurboCell-TxRate TxRate-947k 947
+VALUE KarlNet-TurboCell-TxRate TxRate-948k 948
+VALUE KarlNet-TurboCell-TxRate TxRate-949k 949
+VALUE KarlNet-TurboCell-TxRate TxRate-950k 950
+VALUE KarlNet-TurboCell-TxRate TxRate-951k 951
+VALUE KarlNet-TurboCell-TxRate TxRate-952k 952
+VALUE KarlNet-TurboCell-TxRate TxRate-953k 953
+VALUE KarlNet-TurboCell-TxRate TxRate-954k 954
+VALUE KarlNet-TurboCell-TxRate TxRate-955k 955
+VALUE KarlNet-TurboCell-TxRate TxRate-956k 956
+VALUE KarlNet-TurboCell-TxRate TxRate-957k 957
+VALUE KarlNet-TurboCell-TxRate TxRate-958k 958
+VALUE KarlNet-TurboCell-TxRate TxRate-959k 959
+VALUE KarlNet-TurboCell-TxRate TxRate-960k 960
+VALUE KarlNet-TurboCell-TxRate TxRate-961k 961
+VALUE KarlNet-TurboCell-TxRate TxRate-962k 962
+VALUE KarlNet-TurboCell-TxRate TxRate-963k 963
+VALUE KarlNet-TurboCell-TxRate TxRate-964k 964
+VALUE KarlNet-TurboCell-TxRate TxRate-965k 965
+VALUE KarlNet-TurboCell-TxRate TxRate-966k 966
+VALUE KarlNet-TurboCell-TxRate TxRate-967k 967
+VALUE KarlNet-TurboCell-TxRate TxRate-968k 968
+VALUE KarlNet-TurboCell-TxRate TxRate-969k 969
+VALUE KarlNet-TurboCell-TxRate TxRate-970k 970
+VALUE KarlNet-TurboCell-TxRate TxRate-971k 971
+VALUE KarlNet-TurboCell-TxRate TxRate-972k 972
+VALUE KarlNet-TurboCell-TxRate TxRate-973k 973
+VALUE KarlNet-TurboCell-TxRate TxRate-974k 974
+VALUE KarlNet-TurboCell-TxRate TxRate-975k 975
+VALUE KarlNet-TurboCell-TxRate TxRate-976k 976
+VALUE KarlNet-TurboCell-TxRate TxRate-977k 977
+VALUE KarlNet-TurboCell-TxRate TxRate-978k 978
+VALUE KarlNet-TurboCell-TxRate TxRate-979k 979
+VALUE KarlNet-TurboCell-TxRate TxRate-980k 980
+VALUE KarlNet-TurboCell-TxRate TxRate-981k 981
+VALUE KarlNet-TurboCell-TxRate TxRate-982k 982
+VALUE KarlNet-TurboCell-TxRate TxRate-983k 983
+VALUE KarlNet-TurboCell-TxRate TxRate-984k 984
+VALUE KarlNet-TurboCell-TxRate TxRate-985k 985
+VALUE KarlNet-TurboCell-TxRate TxRate-986k 986
+VALUE KarlNet-TurboCell-TxRate TxRate-987k 987
+VALUE KarlNet-TurboCell-TxRate TxRate-988k 988
+VALUE KarlNet-TurboCell-TxRate TxRate-989k 989
+VALUE KarlNet-TurboCell-TxRate TxRate-990k 990
+VALUE KarlNet-TurboCell-TxRate TxRate-991k 991
+VALUE KarlNet-TurboCell-TxRate TxRate-992k 992
+VALUE KarlNet-TurboCell-TxRate TxRate-993k 993
+VALUE KarlNet-TurboCell-TxRate TxRate-994k 994
+VALUE KarlNet-TurboCell-TxRate TxRate-995k 995
+VALUE KarlNet-TurboCell-TxRate TxRate-996k 996
+VALUE KarlNet-TurboCell-TxRate TxRate-997k 997
+VALUE KarlNet-TurboCell-TxRate TxRate-998k 998
+VALUE KarlNet-TurboCell-TxRate TxRate-999k 999
+VALUE KarlNet-TurboCell-TxRate TxRate-1000k 1000
+VALUE KarlNet-TurboCell-TxRate TxRate-1001k 1001
+VALUE KarlNet-TurboCell-TxRate TxRate-1002k 1002
+VALUE KarlNet-TurboCell-TxRate TxRate-1003k 1003
+VALUE KarlNet-TurboCell-TxRate TxRate-1004k 1004
+VALUE KarlNet-TurboCell-TxRate TxRate-1005k 1005
+VALUE KarlNet-TurboCell-TxRate TxRate-1006k 1006
+VALUE KarlNet-TurboCell-TxRate TxRate-1007k 1007
+VALUE KarlNet-TurboCell-TxRate TxRate-1008k 1008
+VALUE KarlNet-TurboCell-TxRate TxRate-1009k 1009
+VALUE KarlNet-TurboCell-TxRate TxRate-1010k 1010
+VALUE KarlNet-TurboCell-TxRate TxRate-1011k 1011
+VALUE KarlNet-TurboCell-TxRate TxRate-1012k 1012
+VALUE KarlNet-TurboCell-TxRate TxRate-1013k 1013
+VALUE KarlNet-TurboCell-TxRate TxRate-1014k 1014
+VALUE KarlNet-TurboCell-TxRate TxRate-1015k 1015
+VALUE KarlNet-TurboCell-TxRate TxRate-1016k 1016
+VALUE KarlNet-TurboCell-TxRate TxRate-1017k 1017
+VALUE KarlNet-TurboCell-TxRate TxRate-1018k 1018
+VALUE KarlNet-TurboCell-TxRate TxRate-1019k 1019
+VALUE KarlNet-TurboCell-TxRate TxRate-1020k 1020
+VALUE KarlNet-TurboCell-TxRate TxRate-1021k 1021
+VALUE KarlNet-TurboCell-TxRate TxRate-1022k 1022
+VALUE KarlNet-TurboCell-TxRate TxRate-1023k 1023
+VALUE KarlNet-TurboCell-TxRate TxRate-1024k 1024
+VALUE KarlNet-TurboCell-TxRate TxRate-1152k 1025
+VALUE KarlNet-TurboCell-TxRate TxRate-1280k 1026
+VALUE KarlNet-TurboCell-TxRate TxRate-1408k 1027
+VALUE KarlNet-TurboCell-TxRate TxRate-1536k 1028
+VALUE KarlNet-TurboCell-TxRate TxRate-1664k 1029
+VALUE KarlNet-TurboCell-TxRate TxRate-1792k 1030
+VALUE KarlNet-TurboCell-TxRate TxRate-1920k 1031
+VALUE KarlNet-TurboCell-TxRate TxRate-2048k 1032
+VALUE KarlNet-TurboCell-TxRate TxRate-2176k 1033
+VALUE KarlNet-TurboCell-TxRate TxRate-2304k 1034
+VALUE KarlNet-TurboCell-TxRate TxRate-2432k 1035
+VALUE KarlNet-TurboCell-TxRate TxRate-2560k 1036
+VALUE KarlNet-TurboCell-TxRate TxRate-2688k 1037
+VALUE KarlNet-TurboCell-TxRate TxRate-2816k 1038
+VALUE KarlNet-TurboCell-TxRate TxRate-2944k 1039
+VALUE KarlNet-TurboCell-TxRate TxRate-3072k 1040
+VALUE KarlNet-TurboCell-TxRate TxRate-3200k 1041
+VALUE KarlNet-TurboCell-TxRate TxRate-3328k 1042
+VALUE KarlNet-TurboCell-TxRate TxRate-3456k 1043
+VALUE KarlNet-TurboCell-TxRate TxRate-3584k 1044
+VALUE KarlNet-TurboCell-TxRate TxRate-3712k 1045
+VALUE KarlNet-TurboCell-TxRate TxRate-3840k 1046
+VALUE KarlNet-TurboCell-TxRate TxRate-3968k 1047
+VALUE KarlNet-TurboCell-TxRate TxRate-4096k 1048
+VALUE KarlNet-TurboCell-TxRate TxRate-4224k 1049
+VALUE KarlNet-TurboCell-TxRate TxRate-4352k 1050
+VALUE KarlNet-TurboCell-TxRate TxRate-4480k 1051
+VALUE KarlNet-TurboCell-TxRate TxRate-4608k 1052
+VALUE KarlNet-TurboCell-TxRate TxRate-4736k 1053
+VALUE KarlNet-TurboCell-TxRate TxRate-4864k 1054
+VALUE KarlNet-TurboCell-TxRate TxRate-4992k 1055
+VALUE KarlNet-TurboCell-TxRate TxRate-5120k 1056
+VALUE KarlNet-TurboCell-TxRate TxRate-5248k 1057
+VALUE KarlNet-TurboCell-TxRate TxRate-5376k 1058
+VALUE KarlNet-TurboCell-TxRate TxRate-5504k 1059
+VALUE KarlNet-TurboCell-TxRate TxRate-5632k 1060
+VALUE KarlNet-TurboCell-TxRate TxRate-5760k 1061
+VALUE KarlNet-TurboCell-TxRate TxRate-5888k 1062
+VALUE KarlNet-TurboCell-TxRate TxRate-6016k 1063
+VALUE KarlNet-TurboCell-TxRate TxRate-6144k 1064
+VALUE KarlNet-TurboCell-TxRate TxRate-6272k 1065
+VALUE KarlNet-TurboCell-TxRate TxRate-6400k 1066
+VALUE KarlNet-TurboCell-TxRate TxRate-6528k 1067
+VALUE KarlNet-TurboCell-TxRate TxRate-6656k 1068
+VALUE KarlNet-TurboCell-TxRate TxRate-6784k 1069
+VALUE KarlNet-TurboCell-TxRate TxRate-6912k 1070
+VALUE KarlNet-TurboCell-TxRate TxRate-7040k 1071
+VALUE KarlNet-TurboCell-TxRate TxRate-7168k 1072
+VALUE KarlNet-TurboCell-TxRate TxRate-7296k 1073
+VALUE KarlNet-TurboCell-TxRate TxRate-7424k 1074
+VALUE KarlNet-TurboCell-TxRate TxRate-7552k 1075
+VALUE KarlNet-TurboCell-TxRate TxRate-7680k 1076
+VALUE KarlNet-TurboCell-TxRate TxRate-7808k 1077
+VALUE KarlNet-TurboCell-TxRate TxRate-7936k 1078
+VALUE KarlNet-TurboCell-TxRate TxRate-8064k 1079
+VALUE KarlNet-TurboCell-TxRate TxRate-8192k 1080
+VALUE KarlNet-TurboCell-TxRate TxRate-8320k 1081
+VALUE KarlNet-TurboCell-TxRate TxRate-8448k 1082
+VALUE KarlNet-TurboCell-TxRate TxRate-8576k 1083
+VALUE KarlNet-TurboCell-TxRate TxRate-8704k 1084
+VALUE KarlNet-TurboCell-TxRate TxRate-8832k 1085
+VALUE KarlNet-TurboCell-TxRate TxRate-8960k 1086
+VALUE KarlNet-TurboCell-TxRate TxRate-9088k 1087
+VALUE KarlNet-TurboCell-TxRate TxRate-9216k 1088
+VALUE KarlNet-TurboCell-TxRate TxRate-9344k 1089
+VALUE KarlNet-TurboCell-TxRate TxRate-9472k 1090
+VALUE KarlNet-TurboCell-TxRate TxRate-9600k 1091
+VALUE KarlNet-TurboCell-TxRate TxRate-9728k 1092
+VALUE KarlNet-TurboCell-TxRate TxRate-9856k 1093
+VALUE KarlNet-TurboCell-TxRate TxRate-9984k 1094
+VALUE KarlNet-TurboCell-TxRate TxRate-10112k 1095
+VALUE KarlNet-TurboCell-TxRate TxRate-10240k 1096
+VALUE KarlNet-TurboCell-TxRate TxRate-10368k 1097
+VALUE KarlNet-TurboCell-TxRate TxRate-10496k 1098
+VALUE KarlNet-TurboCell-TxRate TxRate-10624k 1099
+VALUE KarlNet-TurboCell-TxRate TxRate-10752k 1100
+VALUE KarlNet-TurboCell-TxRate TxRate-10880k 1101
+VALUE KarlNet-TurboCell-TxRate TxRate-11008k 1102
+VALUE KarlNet-TurboCell-TxRate TxRate-11136k 1103
+VALUE KarlNet-TurboCell-TxRate TxRate-11264k 1104
+VALUE KarlNet-TurboCell-TxRate TxRate-11392k 1105
+VALUE KarlNet-TurboCell-TxRate TxRate-11520k 1106
+VALUE KarlNet-TurboCell-TxRate TxRate-11648k 1107
+VALUE KarlNet-TurboCell-TxRate TxRate-11776k 1108
+VALUE KarlNet-TurboCell-TxRate TxRate-11904k 1109
+VALUE KarlNet-TurboCell-TxRate TxRate-12032k 1110
+VALUE KarlNet-TurboCell-TxRate TxRate-12160k 1111
+VALUE KarlNet-TurboCell-TxRate TxRate-12288k 1112
+VALUE KarlNet-TurboCell-TxRate TxRate-12416k 1113
+VALUE KarlNet-TurboCell-TxRate TxRate-12544k 1114
+VALUE KarlNet-TurboCell-TxRate TxRate-12672k 1115
+VALUE KarlNet-TurboCell-TxRate TxRate-12800k 1116
+VALUE KarlNet-TurboCell-TxRate TxRate-12928k 1117
+VALUE KarlNet-TurboCell-TxRate TxRate-13056k 1118
+VALUE KarlNet-TurboCell-TxRate TxRate-13184k 1119
+VALUE KarlNet-TurboCell-TxRate TxRate-13312k 1120
+VALUE KarlNet-TurboCell-TxRate TxRate-13440k 1121
+VALUE KarlNet-TurboCell-TxRate TxRate-13568k 1122
+VALUE KarlNet-TurboCell-TxRate TxRate-13696k 1123
+VALUE KarlNet-TurboCell-TxRate TxRate-13824k 1124
+VALUE KarlNet-TurboCell-TxRate TxRate-13952k 1125
+VALUE KarlNet-TurboCell-TxRate TxRate-14080k 1126
+VALUE KarlNet-TurboCell-TxRate TxRate-14208k 1127
+VALUE KarlNet-TurboCell-TxRate TxRate-14336k 1128
+VALUE KarlNet-TurboCell-TxRate TxRate-14464k 1129
+VALUE KarlNet-TurboCell-TxRate TxRate-14592k 1130
+VALUE KarlNet-TurboCell-TxRate TxRate-14720k 1131
+VALUE KarlNet-TurboCell-TxRate TxRate-14848k 1132
+VALUE KarlNet-TurboCell-TxRate TxRate-14976k 1133
+VALUE KarlNet-TurboCell-TxRate TxRate-15104k 1134
+VALUE KarlNet-TurboCell-TxRate TxRate-15232k 1135
+VALUE KarlNet-TurboCell-TxRate TxRate-15360k 1136
+VALUE KarlNet-TurboCell-TxRate TxRate-15488k 1137
+VALUE KarlNet-TurboCell-TxRate TxRate-15616k 1138
+VALUE KarlNet-TurboCell-TxRate TxRate-15744k 1139
+VALUE KarlNet-TurboCell-TxRate TxRate-15872k 1140
+VALUE KarlNet-TurboCell-TxRate TxRate-16000k 1141
+VALUE KarlNet-TurboCell-TxRate TxRate-16128k 1142
+VALUE KarlNet-TurboCell-TxRate TxRate-16256k 1143
+VALUE KarlNet-TurboCell-TxRate TxRate-16384k 1144
+VALUE KarlNet-TurboCell-TxRate TxRate-16512k 1145
+VALUE KarlNet-TurboCell-TxRate TxRate-16640k 1146
+VALUE KarlNet-TurboCell-TxRate TxRate-16768k 1147
+VALUE KarlNet-TurboCell-TxRate TxRate-16896k 1148
+VALUE KarlNet-TurboCell-TxRate TxRate-17024k 1149
+VALUE KarlNet-TurboCell-TxRate TxRate-17152k 1150
+VALUE KarlNet-TurboCell-TxRate TxRate-17280k 1151
+VALUE KarlNet-TurboCell-TxRate TxRate-17408k 1152
+VALUE KarlNet-TurboCell-TxRate TxRate-17536k 1153
+VALUE KarlNet-TurboCell-TxRate TxRate-17664k 1154
+VALUE KarlNet-TurboCell-TxRate TxRate-17792k 1155
+VALUE KarlNet-TurboCell-TxRate TxRate-17920k 1156
+VALUE KarlNet-TurboCell-TxRate TxRate-18048k 1157
+VALUE KarlNet-TurboCell-TxRate TxRate-18176k 1158
+VALUE KarlNet-TurboCell-TxRate TxRate-18304k 1159
+VALUE KarlNet-TurboCell-TxRate TxRate-18432k 1160
+VALUE KarlNet-TurboCell-TxRate TxRate-18560k 1161
+VALUE KarlNet-TurboCell-TxRate TxRate-18688k 1162
+VALUE KarlNet-TurboCell-TxRate TxRate-18816k 1163
+VALUE KarlNet-TurboCell-TxRate TxRate-18944k 1164
+VALUE KarlNet-TurboCell-TxRate TxRate-19072k 1165
+VALUE KarlNet-TurboCell-TxRate TxRate-19200k 1166
+VALUE KarlNet-TurboCell-TxRate TxRate-19328k 1167
+VALUE KarlNet-TurboCell-TxRate TxRate-19456k 1168
+VALUE KarlNet-TurboCell-TxRate TxRate-19584k 1169
+VALUE KarlNet-TurboCell-TxRate TxRate-19712k 1170
+VALUE KarlNet-TurboCell-TxRate TxRate-19840k 1171
+VALUE KarlNet-TurboCell-TxRate TxRate-19968k 1172
+VALUE KarlNet-TurboCell-TxRate TxRate-20096k 1173
+VALUE KarlNet-TurboCell-TxRate TxRate-20224k 1174
+VALUE KarlNet-TurboCell-TxRate TxRate-20352k 1175
+VALUE KarlNet-TurboCell-TxRate TxRate-20480k 1176
+VALUE KarlNet-TurboCell-TxRate TxRate-20608k 1177
+VALUE KarlNet-TurboCell-TxRate TxRate-20736k 1178
+VALUE KarlNet-TurboCell-TxRate TxRate-20864k 1179
+VALUE KarlNet-TurboCell-TxRate TxRate-20992k 1180
+VALUE KarlNet-TurboCell-TxRate TxRate-21120k 1181
+VALUE KarlNet-TurboCell-TxRate TxRate-21248k 1182
+VALUE KarlNet-TurboCell-TxRate TxRate-21376k 1183
+VALUE KarlNet-TurboCell-TxRate TxRate-21504k 1184
+VALUE KarlNet-TurboCell-TxRate TxRate-21632k 1185
+VALUE KarlNet-TurboCell-TxRate TxRate-21760k 1186
+VALUE KarlNet-TurboCell-TxRate TxRate-21888k 1187
+VALUE KarlNet-TurboCell-TxRate TxRate-22016k 1188
+VALUE KarlNet-TurboCell-TxRate TxRate-22144k 1189
+VALUE KarlNet-TurboCell-TxRate TxRate-22272k 1190
+VALUE KarlNet-TurboCell-TxRate TxRate-22400k 1191
+VALUE KarlNet-TurboCell-TxRate TxRate-22528k 1192
+VALUE KarlNet-TurboCell-TxRate TxRate-22656k 1193
+VALUE KarlNet-TurboCell-TxRate TxRate-22784k 1194
+VALUE KarlNet-TurboCell-TxRate TxRate-22912k 1195
+VALUE KarlNet-TurboCell-TxRate TxRate-23040k 1196
+VALUE KarlNet-TurboCell-TxRate TxRate-23168k 1197
+VALUE KarlNet-TurboCell-TxRate TxRate-23296k 1198
+VALUE KarlNet-TurboCell-TxRate TxRate-23424k 1199
+VALUE KarlNet-TurboCell-TxRate TxRate-23552k 1200
+VALUE KarlNet-TurboCell-TxRate TxRate-23680k 1201
+VALUE KarlNet-TurboCell-TxRate TxRate-23808k 1202
+VALUE KarlNet-TurboCell-TxRate TxRate-23936k 1203
+VALUE KarlNet-TurboCell-TxRate TxRate-24064k 1204
+VALUE KarlNet-TurboCell-TxRate TxRate-24192k 1205
+VALUE KarlNet-TurboCell-TxRate TxRate-24320k 1206
+VALUE KarlNet-TurboCell-TxRate TxRate-24448k 1207
+VALUE KarlNet-TurboCell-TxRate TxRate-24576k 1208
+VALUE KarlNet-TurboCell-TxRate TxRate-24704k 1209
+VALUE KarlNet-TurboCell-TxRate TxRate-24832k 1210
+VALUE KarlNet-TurboCell-TxRate TxRate-24960k 1211
+VALUE KarlNet-TurboCell-TxRate TxRate-25088k 1212
+VALUE KarlNet-TurboCell-TxRate TxRate-25216k 1213
+VALUE KarlNet-TurboCell-TxRate TxRate-25344k 1214
+VALUE KarlNet-TurboCell-TxRate TxRate-25472k 1215
+VALUE KarlNet-TurboCell-TxRate TxRate-25600k 1216
+VALUE KarlNet-TurboCell-TxRate TxRate-25728k 1217
+VALUE KarlNet-TurboCell-TxRate TxRate-25856k 1218
+VALUE KarlNet-TurboCell-TxRate TxRate-25984k 1219
+VALUE KarlNet-TurboCell-TxRate TxRate-26112k 1220
+VALUE KarlNet-TurboCell-TxRate TxRate-26240k 1221
+VALUE KarlNet-TurboCell-TxRate TxRate-26368k 1222
+VALUE KarlNet-TurboCell-TxRate TxRate-26496k 1223
+VALUE KarlNet-TurboCell-TxRate TxRate-26624k 1224
+VALUE KarlNet-TurboCell-TxRate TxRate-26752k 1225
+VALUE KarlNet-TurboCell-TxRate TxRate-26880k 1226
+VALUE KarlNet-TurboCell-TxRate TxRate-27008k 1227
+VALUE KarlNet-TurboCell-TxRate TxRate-27136k 1228
+VALUE KarlNet-TurboCell-TxRate TxRate-27264k 1229
+VALUE KarlNet-TurboCell-TxRate TxRate-27392k 1230
+VALUE KarlNet-TurboCell-TxRate TxRate-27520k 1231
+VALUE KarlNet-TurboCell-TxRate TxRate-27648k 1232
+VALUE KarlNet-TurboCell-TxRate TxRate-27776k 1233
+VALUE KarlNet-TurboCell-TxRate TxRate-27904k 1234
+VALUE KarlNet-TurboCell-TxRate TxRate-28032k 1235
+VALUE KarlNet-TurboCell-TxRate TxRate-28160k 1236
+VALUE KarlNet-TurboCell-TxRate TxRate-28288k 1237
+VALUE KarlNet-TurboCell-TxRate TxRate-28416k 1238
+VALUE KarlNet-TurboCell-TxRate TxRate-28544k 1239
+VALUE KarlNet-TurboCell-TxRate TxRate-28672k 1240
+VALUE KarlNet-TurboCell-TxRate TxRate-28800k 1241
+VALUE KarlNet-TurboCell-TxRate TxRate-28928k 1242
+VALUE KarlNet-TurboCell-TxRate TxRate-29056k 1243
+VALUE KarlNet-TurboCell-TxRate TxRate-29184k 1244
+VALUE KarlNet-TurboCell-TxRate TxRate-29312k 1245
+VALUE KarlNet-TurboCell-TxRate TxRate-29440k 1246
+VALUE KarlNet-TurboCell-TxRate TxRate-29568k 1247
+VALUE KarlNet-TurboCell-TxRate TxRate-29696k 1248
+VALUE KarlNet-TurboCell-TxRate TxRate-29824k 1249
+VALUE KarlNet-TurboCell-TxRate TxRate-29952k 1250
+VALUE KarlNet-TurboCell-TxRate TxRate-30080k 1251
+VALUE KarlNet-TurboCell-TxRate TxRate-30208k 1252
+VALUE KarlNet-TurboCell-TxRate TxRate-30336k 1253
+VALUE KarlNet-TurboCell-TxRate TxRate-30464k 1254
+VALUE KarlNet-TurboCell-TxRate TxRate-30592k 1255
+VALUE KarlNet-TurboCell-TxRate TxRate-30720k 1256
+VALUE KarlNet-TurboCell-TxRate TxRate-30848k 1257
+VALUE KarlNet-TurboCell-TxRate TxRate-30976k 1258
+VALUE KarlNet-TurboCell-TxRate TxRate-31104k 1259
+VALUE KarlNet-TurboCell-TxRate TxRate-31232k 1260
+VALUE KarlNet-TurboCell-TxRate TxRate-31360k 1261
+VALUE KarlNet-TurboCell-TxRate TxRate-31488k 1262
+VALUE KarlNet-TurboCell-TxRate TxRate-31616k 1263
+VALUE KarlNet-TurboCell-TxRate TxRate-31744k 1264
+VALUE KarlNet-TurboCell-TxRate TxRate-31872k 1265
+VALUE KarlNet-TurboCell-TxRate TxRate-32000k 1266
+VALUE KarlNet-TurboCell-TxRate TxRate-32128k 1267
+VALUE KarlNet-TurboCell-TxRate TxRate-32256k 1268
+VALUE KarlNet-TurboCell-TxRate TxRate-32384k 1269
+VALUE KarlNet-TurboCell-TxRate TxRate-32512k 1270
+VALUE KarlNet-TurboCell-TxRate TxRate-32640k 1271
+VALUE KarlNet-TurboCell-TxRate TxRate-32768k 1272
+VALUE KarlNet-TurboCell-TxRate TxRate-32896k 1273
+VALUE KarlNet-TurboCell-TxRate TxRate-33024k 1274
+VALUE KarlNet-TurboCell-TxRate TxRate-33152k 1275
+VALUE KarlNet-TurboCell-TxRate TxRate-33280k 1276
+VALUE KarlNet-TurboCell-TxRate TxRate-33408k 1277
+VALUE KarlNet-TurboCell-TxRate TxRate-33536k 1278
+VALUE KarlNet-TurboCell-TxRate TxRate-33664k 1279
+VALUE KarlNet-TurboCell-TxRate TxRate-33792k 1280
+VALUE KarlNet-TurboCell-TxRate TxRate-33920k 1281
+VALUE KarlNet-TurboCell-TxRate TxRate-34048k 1282
+VALUE KarlNet-TurboCell-TxRate TxRate-34176k 1283
+VALUE KarlNet-TurboCell-TxRate TxRate-34304k 1284
+VALUE KarlNet-TurboCell-TxRate TxRate-34432k 1285
+VALUE KarlNet-TurboCell-TxRate TxRate-34560k 1286
+VALUE KarlNet-TurboCell-TxRate TxRate-34688k 1287
+VALUE KarlNet-TurboCell-TxRate TxRate-34816k 1288
+VALUE KarlNet-TurboCell-TxRate TxRate-34944k 1289
+VALUE KarlNet-TurboCell-TxRate TxRate-35072k 1290
+VALUE KarlNet-TurboCell-TxRate TxRate-35200k 1291
+VALUE KarlNet-TurboCell-TxRate TxRate-35328k 1292
+VALUE KarlNet-TurboCell-TxRate TxRate-35456k 1293
+VALUE KarlNet-TurboCell-TxRate TxRate-35584k 1294
+VALUE KarlNet-TurboCell-TxRate TxRate-35712k 1295
+VALUE KarlNet-TurboCell-TxRate TxRate-35840k 1296
+VALUE KarlNet-TurboCell-TxRate TxRate-35968k 1297
+VALUE KarlNet-TurboCell-TxRate TxRate-36096k 1298
+VALUE KarlNet-TurboCell-TxRate TxRate-36224k 1299
+VALUE KarlNet-TurboCell-TxRate TxRate-36352k 1300
+VALUE KarlNet-TurboCell-TxRate TxRate-36480k 1301
+VALUE KarlNet-TurboCell-TxRate TxRate-36608k 1302
+VALUE KarlNet-TurboCell-TxRate TxRate-36736k 1303
+VALUE KarlNet-TurboCell-TxRate TxRate-36864k 1304
+VALUE KarlNet-TurboCell-TxRate TxRate-36992k 1305
+VALUE KarlNet-TurboCell-TxRate TxRate-37120k 1306
+VALUE KarlNet-TurboCell-TxRate TxRate-37248k 1307
+VALUE KarlNet-TurboCell-TxRate TxRate-37376k 1308
+VALUE KarlNet-TurboCell-TxRate TxRate-37504k 1309
+VALUE KarlNet-TurboCell-TxRate TxRate-37632k 1310
+VALUE KarlNet-TurboCell-TxRate TxRate-37760k 1311
+VALUE KarlNet-TurboCell-TxRate TxRate-37888k 1312
+VALUE KarlNet-TurboCell-TxRate TxRate-38016k 1313
+VALUE KarlNet-TurboCell-TxRate TxRate-38144k 1314
+VALUE KarlNet-TurboCell-TxRate TxRate-38272k 1315
+VALUE KarlNet-TurboCell-TxRate TxRate-38400k 1316
+VALUE KarlNet-TurboCell-TxRate TxRate-38528k 1317
+VALUE KarlNet-TurboCell-TxRate TxRate-38656k 1318
+VALUE KarlNet-TurboCell-TxRate TxRate-38784k 1319
+VALUE KarlNet-TurboCell-TxRate TxRate-38912k 1320
+VALUE KarlNet-TurboCell-TxRate TxRate-39040k 1321
+VALUE KarlNet-TurboCell-TxRate TxRate-39168k 1322
+VALUE KarlNet-TurboCell-TxRate TxRate-39296k 1323
+VALUE KarlNet-TurboCell-TxRate TxRate-39424k 1324
+VALUE KarlNet-TurboCell-TxRate TxRate-39552k 1325
+VALUE KarlNet-TurboCell-TxRate TxRate-39680k 1326
+VALUE KarlNet-TurboCell-TxRate TxRate-39808k 1327
+VALUE KarlNet-TurboCell-TxRate TxRate-39936k 1328
+VALUE KarlNet-TurboCell-TxRate TxRate-40064k 1329
+VALUE KarlNet-TurboCell-TxRate TxRate-40192k 1330
+VALUE KarlNet-TurboCell-TxRate TxRate-40320k 1331
+VALUE KarlNet-TurboCell-TxRate TxRate-40448k 1332
+VALUE KarlNet-TurboCell-TxRate TxRate-40576k 1333
+VALUE KarlNet-TurboCell-TxRate TxRate-40704k 1334
+VALUE KarlNet-TurboCell-TxRate TxRate-40832k 1335
+VALUE KarlNet-TurboCell-TxRate TxRate-40960k 1336
+VALUE KarlNet-TurboCell-TxRate TxRate-41088k 1337
+VALUE KarlNet-TurboCell-TxRate TxRate-41216k 1338
+VALUE KarlNet-TurboCell-TxRate TxRate-41344k 1339
+VALUE KarlNet-TurboCell-TxRate TxRate-41472k 1340
+VALUE KarlNet-TurboCell-TxRate TxRate-41600k 1341
+VALUE KarlNet-TurboCell-TxRate TxRate-41728k 1342
+VALUE KarlNet-TurboCell-TxRate TxRate-41856k 1343
+VALUE KarlNet-TurboCell-TxRate TxRate-41984k 1344
+VALUE KarlNet-TurboCell-TxRate TxRate-42112k 1345
+VALUE KarlNet-TurboCell-TxRate TxRate-42240k 1346
+VALUE KarlNet-TurboCell-TxRate TxRate-42368k 1347
+VALUE KarlNet-TurboCell-TxRate TxRate-42496k 1348
+VALUE KarlNet-TurboCell-TxRate TxRate-42624k 1349
+VALUE KarlNet-TurboCell-TxRate TxRate-42752k 1350
+VALUE KarlNet-TurboCell-TxRate TxRate-42880k 1351
+VALUE KarlNet-TurboCell-TxRate TxRate-43008k 1352
+VALUE KarlNet-TurboCell-TxRate TxRate-43136k 1353
+VALUE KarlNet-TurboCell-TxRate TxRate-43264k 1354
+VALUE KarlNet-TurboCell-TxRate TxRate-43392k 1355
+VALUE KarlNet-TurboCell-TxRate TxRate-43520k 1356
+VALUE KarlNet-TurboCell-TxRate TxRate-43648k 1357
+VALUE KarlNet-TurboCell-TxRate TxRate-43776k 1358
+VALUE KarlNet-TurboCell-TxRate TxRate-43904k 1359
+VALUE KarlNet-TurboCell-TxRate TxRate-44032k 1360
+VALUE KarlNet-TurboCell-TxRate TxRate-44160k 1361
+VALUE KarlNet-TurboCell-TxRate TxRate-44288k 1362
+VALUE KarlNet-TurboCell-TxRate TxRate-44416k 1363
+VALUE KarlNet-TurboCell-TxRate TxRate-44544k 1364
+VALUE KarlNet-TurboCell-TxRate TxRate-44672k 1365
+VALUE KarlNet-TurboCell-TxRate TxRate-44800k 1366
+VALUE KarlNet-TurboCell-TxRate TxRate-44928k 1367
+VALUE KarlNet-TurboCell-TxRate TxRate-45056k 1368
+VALUE KarlNet-TurboCell-TxRate TxRate-45184k 1369
+VALUE KarlNet-TurboCell-TxRate TxRate-45312k 1370
+VALUE KarlNet-TurboCell-TxRate TxRate-45440k 1371
+VALUE KarlNet-TurboCell-TxRate TxRate-45568k 1372
+VALUE KarlNet-TurboCell-TxRate TxRate-45696k 1373
+VALUE KarlNet-TurboCell-TxRate TxRate-45824k 1374
+VALUE KarlNet-TurboCell-TxRate TxRate-45952k 1375
+VALUE KarlNet-TurboCell-TxRate TxRate-46080k 1376
+VALUE KarlNet-TurboCell-TxRate TxRate-46208k 1377
+VALUE KarlNet-TurboCell-TxRate TxRate-46336k 1378
+VALUE KarlNet-TurboCell-TxRate TxRate-46464k 1379
+VALUE KarlNet-TurboCell-TxRate TxRate-46592k 1380
+VALUE KarlNet-TurboCell-TxRate TxRate-46720k 1381
+VALUE KarlNet-TurboCell-TxRate TxRate-46848k 1382
+VALUE KarlNet-TurboCell-TxRate TxRate-46976k 1383
+VALUE KarlNet-TurboCell-TxRate TxRate-47104k 1384
+VALUE KarlNet-TurboCell-TxRate TxRate-47232k 1385
+VALUE KarlNet-TurboCell-TxRate TxRate-47360k 1386
+VALUE KarlNet-TurboCell-TxRate TxRate-47488k 1387
+VALUE KarlNet-TurboCell-TxRate TxRate-47616k 1388
+VALUE KarlNet-TurboCell-TxRate TxRate-47744k 1389
+VALUE KarlNet-TurboCell-TxRate TxRate-47872k 1390
+VALUE KarlNet-TurboCell-TxRate TxRate-48000k 1391
+VALUE KarlNet-TurboCell-TxRate TxRate-48128k 1392
+VALUE KarlNet-TurboCell-TxRate TxRate-48256k 1393
+VALUE KarlNet-TurboCell-TxRate TxRate-48384k 1394
+VALUE KarlNet-TurboCell-TxRate TxRate-48512k 1395
+VALUE KarlNet-TurboCell-TxRate TxRate-48640k 1396
+VALUE KarlNet-TurboCell-TxRate TxRate-48768k 1397
+VALUE KarlNet-TurboCell-TxRate TxRate-48896k 1398
+VALUE KarlNet-TurboCell-TxRate TxRate-49024k 1399
+VALUE KarlNet-TurboCell-TxRate TxRate-49152k 1400
+VALUE KarlNet-TurboCell-TxRate TxRate-49280k 1401
+VALUE KarlNet-TurboCell-TxRate TxRate-49408k 1402
+VALUE KarlNet-TurboCell-TxRate TxRate-49536k 1403
+VALUE KarlNet-TurboCell-TxRate TxRate-49664k 1404
+VALUE KarlNet-TurboCell-TxRate TxRate-49792k 1405
+VALUE KarlNet-TurboCell-TxRate TxRate-49920k 1406
+VALUE KarlNet-TurboCell-TxRate TxRate-50048k 1407
+VALUE KarlNet-TurboCell-TxRate TxRate-50176k 1408
+VALUE KarlNet-TurboCell-TxRate TxRate-50304k 1409
+VALUE KarlNet-TurboCell-TxRate TxRate-50432k 1410
+VALUE KarlNet-TurboCell-TxRate TxRate-50560k 1411
+VALUE KarlNet-TurboCell-TxRate TxRate-50688k 1412
+VALUE KarlNet-TurboCell-TxRate TxRate-50816k 1413
+VALUE KarlNet-TurboCell-TxRate TxRate-50944k 1414
+VALUE KarlNet-TurboCell-TxRate TxRate-51072k 1415
+VALUE KarlNet-TurboCell-TxRate TxRate-51200k 1416
+VALUE KarlNet-TurboCell-TxRate TxRate-51328k 1417
+VALUE KarlNet-TurboCell-TxRate TxRate-51456k 1418
+VALUE KarlNet-TurboCell-TxRate TxRate-51584k 1419
+VALUE KarlNet-TurboCell-TxRate TxRate-51712k 1420
+VALUE KarlNet-TurboCell-TxRate TxRate-51840k 1421
+VALUE KarlNet-TurboCell-TxRate TxRate-51968k 1422
+VALUE KarlNet-TurboCell-TxRate TxRate-52096k 1423
+VALUE KarlNet-TurboCell-TxRate TxRate-52224k 1424
+VALUE KarlNet-TurboCell-TxRate TxRate-52352k 1425
+VALUE KarlNet-TurboCell-TxRate TxRate-52480k 1426
+VALUE KarlNet-TurboCell-TxRate TxRate-52608k 1427
+VALUE KarlNet-TurboCell-TxRate TxRate-52736k 1428
+VALUE KarlNet-TurboCell-TxRate TxRate-52864k 1429
+VALUE KarlNet-TurboCell-TxRate TxRate-52992k 1430
+VALUE KarlNet-TurboCell-TxRate TxRate-53120k 1431
+VALUE KarlNet-TurboCell-TxRate TxRate-53248k 1432
+VALUE KarlNet-TurboCell-TxRate TxRate-53376k 1433
+VALUE KarlNet-TurboCell-TxRate TxRate-53504k 1434
+VALUE KarlNet-TurboCell-TxRate TxRate-53632k 1435
+VALUE KarlNet-TurboCell-TxRate TxRate-53760k 1436
+VALUE KarlNet-TurboCell-TxRate TxRate-53888k 1437
+VALUE KarlNet-TurboCell-TxRate TxRate-54016k 1438
+VALUE KarlNet-TurboCell-TxRate TxRate-54144k 1439
+VALUE KarlNet-TurboCell-TxRate TxRate-54272k 1440
+VALUE KarlNet-TurboCell-TxRate TxRate-54400k 1441
+VALUE KarlNet-TurboCell-TxRate TxRate-54528k 1442
+VALUE KarlNet-TurboCell-TxRate TxRate-54656k 1443
+VALUE KarlNet-TurboCell-TxRate TxRate-54784k 1444
+VALUE KarlNet-TurboCell-TxRate TxRate-54912k 1445
+VALUE KarlNet-TurboCell-TxRate TxRate-55040k 1446
+VALUE KarlNet-TurboCell-TxRate TxRate-55168k 1447
+VALUE KarlNet-TurboCell-TxRate TxRate-55296k 1448
+VALUE KarlNet-TurboCell-TxRate TxRate-55424k 1449
+VALUE KarlNet-TurboCell-TxRate TxRate-55552k 1450
+VALUE KarlNet-TurboCell-TxRate TxRate-55680k 1451
+VALUE KarlNet-TurboCell-TxRate TxRate-55808k 1452
+VALUE KarlNet-TurboCell-TxRate TxRate-55936k 1453
+VALUE KarlNet-TurboCell-TxRate TxRate-56064k 1454
+VALUE KarlNet-TurboCell-TxRate TxRate-56192k 1455
+VALUE KarlNet-TurboCell-TxRate TxRate-56320k 1456
+VALUE KarlNet-TurboCell-TxRate TxRate-56448k 1457
+VALUE KarlNet-TurboCell-TxRate TxRate-56576k 1458
+VALUE KarlNet-TurboCell-TxRate TxRate-56704k 1459
+VALUE KarlNet-TurboCell-TxRate TxRate-56832k 1460
+VALUE KarlNet-TurboCell-TxRate TxRate-56960k 1461
+VALUE KarlNet-TurboCell-TxRate TxRate-57088k 1462
+VALUE KarlNet-TurboCell-TxRate TxRate-57216k 1463
+VALUE KarlNet-TurboCell-TxRate TxRate-57344k 1464
+VALUE KarlNet-TurboCell-TxRate TxRate-57472k 1465
+VALUE KarlNet-TurboCell-TxRate TxRate-57600k 1466
+VALUE KarlNet-TurboCell-TxRate TxRate-57728k 1467
+VALUE KarlNet-TurboCell-TxRate TxRate-57856k 1468
+VALUE KarlNet-TurboCell-TxRate TxRate-57984k 1469
+VALUE KarlNet-TurboCell-TxRate TxRate-58112k 1470
+VALUE KarlNet-TurboCell-TxRate TxRate-58240k 1471
+VALUE KarlNet-TurboCell-TxRate TxRate-58368k 1472
+VALUE KarlNet-TurboCell-TxRate TxRate-58496k 1473
+VALUE KarlNet-TurboCell-TxRate TxRate-58624k 1474
+VALUE KarlNet-TurboCell-TxRate TxRate-58752k 1475
+VALUE KarlNet-TurboCell-TxRate TxRate-58880k 1476
+VALUE KarlNet-TurboCell-TxRate TxRate-59008k 1477
+VALUE KarlNet-TurboCell-TxRate TxRate-59136k 1478
+VALUE KarlNet-TurboCell-TxRate TxRate-59264k 1479
+VALUE KarlNet-TurboCell-TxRate TxRate-59392k 1480
+VALUE KarlNet-TurboCell-TxRate TxRate-59520k 1481
+VALUE KarlNet-TurboCell-TxRate TxRate-59648k 1482
+VALUE KarlNet-TurboCell-TxRate TxRate-59776k 1483
+VALUE KarlNet-TurboCell-TxRate TxRate-59904k 1484
+VALUE KarlNet-TurboCell-TxRate TxRate-60032k 1485
+VALUE KarlNet-TurboCell-TxRate TxRate-60160k 1486
+VALUE KarlNet-TurboCell-TxRate TxRate-60288k 1487
+VALUE KarlNet-TurboCell-TxRate TxRate-60416k 1488
+VALUE KarlNet-TurboCell-TxRate TxRate-60544k 1489
+VALUE KarlNet-TurboCell-TxRate TxRate-60672k 1490
+VALUE KarlNet-TurboCell-TxRate TxRate-60800k 1491
+VALUE KarlNet-TurboCell-TxRate TxRate-60928k 1492
+VALUE KarlNet-TurboCell-TxRate TxRate-61056k 1493
+VALUE KarlNet-TurboCell-TxRate TxRate-61184k 1494
+VALUE KarlNet-TurboCell-TxRate TxRate-61312k 1495
+VALUE KarlNet-TurboCell-TxRate TxRate-61440k 1496
+VALUE KarlNet-TurboCell-TxRate TxRate-61568k 1497
+VALUE KarlNet-TurboCell-TxRate TxRate-61696k 1498
+VALUE KarlNet-TurboCell-TxRate TxRate-61824k 1499
+VALUE KarlNet-TurboCell-TxRate TxRate-61952k 1500
+VALUE KarlNet-TurboCell-TxRate TxRate-62080k 1501
+VALUE KarlNet-TurboCell-TxRate TxRate-62208k 1502
+VALUE KarlNet-TurboCell-TxRate TxRate-62336k 1503
+VALUE KarlNet-TurboCell-TxRate TxRate-62464k 1504
+VALUE KarlNet-TurboCell-TxRate TxRate-62592k 1505
+VALUE KarlNet-TurboCell-TxRate TxRate-62720k 1506
+VALUE KarlNet-TurboCell-TxRate TxRate-62848k 1507
+VALUE KarlNet-TurboCell-TxRate TxRate-62976k 1508
+VALUE KarlNet-TurboCell-TxRate TxRate-63104k 1509
+VALUE KarlNet-TurboCell-TxRate TxRate-63232k 1510
+VALUE KarlNet-TurboCell-TxRate TxRate-63360k 1511
+VALUE KarlNet-TurboCell-TxRate TxRate-63488k 1512
+VALUE KarlNet-TurboCell-TxRate TxRate-63616k 1513
+VALUE KarlNet-TurboCell-TxRate TxRate-63744k 1514
+VALUE KarlNet-TurboCell-TxRate TxRate-63872k 1515
+VALUE KarlNet-TurboCell-TxRate TxRate-64000k 1516
+VALUE KarlNet-TurboCell-TxRate TxRate-64128k 1517
+VALUE KarlNet-TurboCell-TxRate TxRate-64256k 1518
+VALUE KarlNet-TurboCell-TxRate TxRate-64384k 1519
+VALUE KarlNet-TurboCell-TxRate TxRate-64512k 1520
+VALUE KarlNet-TurboCell-TxRate TxRate-64640k 1521
+VALUE KarlNet-TurboCell-TxRate TxRate-64768k 1522
+VALUE KarlNet-TurboCell-TxRate TxRate-64896k 1523
+VALUE KarlNet-TurboCell-TxRate TxRate-65024k 1524
+VALUE KarlNet-TurboCell-TxRate TxRate-65152k 1525
+VALUE KarlNet-TurboCell-TxRate TxRate-65280k 1526
+VALUE KarlNet-TurboCell-TxRate TxRate-65408k 1527
+VALUE KarlNet-TurboCell-TxRate TxRate-65536k 1528
+VALUE KarlNet-TurboCell-TxRate TxRate-65664k 1529
+VALUE KarlNet-TurboCell-TxRate TxRate-65792k 1530
+VALUE KarlNet-TurboCell-TxRate TxRate-65920k 1531
+VALUE KarlNet-TurboCell-TxRate TxRate-66048k 1532
+VALUE KarlNet-TurboCell-TxRate TxRate-66176k 1533
+VALUE KarlNet-TurboCell-TxRate TxRate-66304k 1534
+VALUE KarlNet-TurboCell-TxRate TxRate-66432k 1535
+VALUE KarlNet-TurboCell-TxRate TxRate-66560k 1536
+VALUE KarlNet-TurboCell-TxRate TxRate-66688k 1537
+VALUE KarlNet-TurboCell-TxRate TxRate-66816k 1538
+VALUE KarlNet-TurboCell-TxRate TxRate-66944k 1539
+VALUE KarlNet-TurboCell-TxRate TxRate-67072k 1540
+VALUE KarlNet-TurboCell-TxRate TxRate-67200k 1541
+VALUE KarlNet-TurboCell-TxRate TxRate-67328k 1542
+VALUE KarlNet-TurboCell-TxRate TxRate-67456k 1543
+VALUE KarlNet-TurboCell-TxRate TxRate-67584k 1544
+VALUE KarlNet-TurboCell-TxRate TxRate-67712k 1545
+VALUE KarlNet-TurboCell-TxRate TxRate-67840k 1546
+VALUE KarlNet-TurboCell-TxRate TxRate-67968k 1547
+VALUE KarlNet-TurboCell-TxRate TxRate-68096k 1548
+VALUE KarlNet-TurboCell-TxRate TxRate-68224k 1549
+VALUE KarlNet-TurboCell-TxRate TxRate-68352k 1550
+VALUE KarlNet-TurboCell-TxRate TxRate-68480k 1551
+VALUE KarlNet-TurboCell-TxRate TxRate-68608k 1552
+VALUE KarlNet-TurboCell-TxRate TxRate-68736k 1553
+VALUE KarlNet-TurboCell-TxRate TxRate-68864k 1554
+VALUE KarlNet-TurboCell-TxRate TxRate-68992k 1555
+VALUE KarlNet-TurboCell-TxRate TxRate-69120k 1556
+VALUE KarlNet-TurboCell-TxRate TxRate-69248k 1557
+VALUE KarlNet-TurboCell-TxRate TxRate-69376k 1558
+VALUE KarlNet-TurboCell-TxRate TxRate-69504k 1559
+VALUE KarlNet-TurboCell-TxRate TxRate-69632k 1560
+VALUE KarlNet-TurboCell-TxRate TxRate-69760k 1561
+VALUE KarlNet-TurboCell-TxRate TxRate-69888k 1562
+VALUE KarlNet-TurboCell-TxRate TxRate-70016k 1563
+VALUE KarlNet-TurboCell-TxRate TxRate-70144k 1564
+VALUE KarlNet-TurboCell-TxRate TxRate-70272k 1565
+VALUE KarlNet-TurboCell-TxRate TxRate-70400k 1566
+VALUE KarlNet-TurboCell-TxRate TxRate-70528k 1567
+VALUE KarlNet-TurboCell-TxRate TxRate-70656k 1568
+VALUE KarlNet-TurboCell-TxRate TxRate-70784k 1569
+VALUE KarlNet-TurboCell-TxRate TxRate-70912k 1570
+VALUE KarlNet-TurboCell-TxRate TxRate-71040k 1571
+VALUE KarlNet-TurboCell-TxRate TxRate-71168k 1572
+VALUE KarlNet-TurboCell-TxRate TxRate-71296k 1573
+VALUE KarlNet-TurboCell-TxRate TxRate-71424k 1574
+VALUE KarlNet-TurboCell-TxRate TxRate-71552k 1575
+VALUE KarlNet-TurboCell-TxRate TxRate-71680k 1576
+VALUE KarlNet-TurboCell-TxRate TxRate-71808k 1577
+VALUE KarlNet-TurboCell-TxRate TxRate-71936k 1578
+VALUE KarlNet-TurboCell-TxRate TxRate-72064k 1579
+VALUE KarlNet-TurboCell-TxRate TxRate-72192k 1580
+VALUE KarlNet-TurboCell-TxRate TxRate-72320k 1581
+VALUE KarlNet-TurboCell-TxRate TxRate-72448k 1582
+VALUE KarlNet-TurboCell-TxRate TxRate-72576k 1583
+VALUE KarlNet-TurboCell-TxRate TxRate-72704k 1584
+VALUE KarlNet-TurboCell-TxRate TxRate-72832k 1585
+VALUE KarlNet-TurboCell-TxRate TxRate-72960k 1586
+VALUE KarlNet-TurboCell-TxRate TxRate-73088k 1587
+VALUE KarlNet-TurboCell-TxRate TxRate-73216k 1588
+VALUE KarlNet-TurboCell-TxRate TxRate-73344k 1589
+VALUE KarlNet-TurboCell-TxRate TxRate-73472k 1590
+VALUE KarlNet-TurboCell-TxRate TxRate-73600k 1591
+VALUE KarlNet-TurboCell-TxRate TxRate-73728k 1592
+VALUE KarlNet-TurboCell-TxRate TxRate-73856k 1593
+VALUE KarlNet-TurboCell-TxRate TxRate-73984k 1594
+VALUE KarlNet-TurboCell-TxRate TxRate-74112k 1595
+VALUE KarlNet-TurboCell-TxRate TxRate-74240k 1596
+VALUE KarlNet-TurboCell-TxRate TxRate-74368k 1597
+VALUE KarlNet-TurboCell-TxRate TxRate-74496k 1598
+VALUE KarlNet-TurboCell-TxRate TxRate-74624k 1599
+VALUE KarlNet-TurboCell-TxRate TxRate-74752k 1600
+VALUE KarlNet-TurboCell-TxRate TxRate-74880k 1601
+VALUE KarlNet-TurboCell-TxRate TxRate-75008k 1602
+VALUE KarlNet-TurboCell-TxRate TxRate-75136k 1603
+VALUE KarlNet-TurboCell-TxRate TxRate-75264k 1604
+VALUE KarlNet-TurboCell-TxRate TxRate-75392k 1605
+VALUE KarlNet-TurboCell-TxRate TxRate-75520k 1606
+VALUE KarlNet-TurboCell-TxRate TxRate-75648k 1607
+VALUE KarlNet-TurboCell-TxRate TxRate-75776k 1608
+VALUE KarlNet-TurboCell-TxRate TxRate-75904k 1609
+VALUE KarlNet-TurboCell-TxRate TxRate-76032k 1610
+VALUE KarlNet-TurboCell-TxRate TxRate-76160k 1611
+VALUE KarlNet-TurboCell-TxRate TxRate-76288k 1612
+VALUE KarlNet-TurboCell-TxRate TxRate-76416k 1613
+VALUE KarlNet-TurboCell-TxRate TxRate-76544k 1614
+VALUE KarlNet-TurboCell-TxRate TxRate-76672k 1615
+VALUE KarlNet-TurboCell-TxRate TxRate-76800k 1616
+VALUE KarlNet-TurboCell-TxRate TxRate-76928k 1617
+VALUE KarlNet-TurboCell-TxRate TxRate-77056k 1618
+VALUE KarlNet-TurboCell-TxRate TxRate-77184k 1619
+VALUE KarlNet-TurboCell-TxRate TxRate-77312k 1620
+VALUE KarlNet-TurboCell-TxRate TxRate-77440k 1621
+VALUE KarlNet-TurboCell-TxRate TxRate-77568k 1622
+VALUE KarlNet-TurboCell-TxRate TxRate-77696k 1623
+VALUE KarlNet-TurboCell-TxRate TxRate-77824k 1624
+VALUE KarlNet-TurboCell-TxRate TxRate-77952k 1625
+VALUE KarlNet-TurboCell-TxRate TxRate-78080k 1626
+VALUE KarlNet-TurboCell-TxRate TxRate-78208k 1627
+VALUE KarlNet-TurboCell-TxRate TxRate-78336k 1628
+VALUE KarlNet-TurboCell-TxRate TxRate-78464k 1629
+VALUE KarlNet-TurboCell-TxRate TxRate-78592k 1630
+VALUE KarlNet-TurboCell-TxRate TxRate-78720k 1631
+VALUE KarlNet-TurboCell-TxRate TxRate-78848k 1632
+VALUE KarlNet-TurboCell-TxRate TxRate-78976k 1633
+VALUE KarlNet-TurboCell-TxRate TxRate-79104k 1634
+VALUE KarlNet-TurboCell-TxRate TxRate-79232k 1635
+VALUE KarlNet-TurboCell-TxRate TxRate-79360k 1636
+VALUE KarlNet-TurboCell-TxRate TxRate-79488k 1637
+VALUE KarlNet-TurboCell-TxRate TxRate-79616k 1638
+VALUE KarlNet-TurboCell-TxRate TxRate-79744k 1639
+VALUE KarlNet-TurboCell-TxRate TxRate-79872k 1640
+VALUE KarlNet-TurboCell-TxRate TxRate-80000k 1641
+VALUE KarlNet-TurboCell-TxRate TxRate-80128k 1642
+VALUE KarlNet-TurboCell-TxRate TxRate-80256k 1643
+VALUE KarlNet-TurboCell-TxRate TxRate-80384k 1644
+VALUE KarlNet-TurboCell-TxRate TxRate-80512k 1645
+VALUE KarlNet-TurboCell-TxRate TxRate-80640k 1646
+VALUE KarlNet-TurboCell-TxRate TxRate-80768k 1647
+VALUE KarlNet-TurboCell-TxRate TxRate-80896k 1648
+VALUE KarlNet-TurboCell-TxRate TxRate-81024k 1649
+VALUE KarlNet-TurboCell-TxRate TxRate-81152k 1650
+VALUE KarlNet-TurboCell-TxRate TxRate-81280k 1651
+VALUE KarlNet-TurboCell-TxRate TxRate-81408k 1652
+VALUE KarlNet-TurboCell-TxRate TxRate-81536k 1653
+VALUE KarlNet-TurboCell-TxRate TxRate-81664k 1654
+VALUE KarlNet-TurboCell-TxRate TxRate-81792k 1655
+VALUE KarlNet-TurboCell-TxRate TxRate-81920k 1656
+VALUE KarlNet-TurboCell-TxRate TxRate-82048k 1657
+VALUE KarlNet-TurboCell-TxRate TxRate-82176k 1658
+VALUE KarlNet-TurboCell-TxRate TxRate-82304k 1659
+VALUE KarlNet-TurboCell-TxRate TxRate-82432k 1660
+VALUE KarlNet-TurboCell-TxRate TxRate-82560k 1661
+VALUE KarlNet-TurboCell-TxRate TxRate-82688k 1662
+VALUE KarlNet-TurboCell-TxRate TxRate-82816k 1663
+VALUE KarlNet-TurboCell-TxRate TxRate-82944k 1664
+VALUE KarlNet-TurboCell-TxRate TxRate-83072k 1665
+VALUE KarlNet-TurboCell-TxRate TxRate-83200k 1666
+VALUE KarlNet-TurboCell-TxRate TxRate-83328k 1667
+VALUE KarlNet-TurboCell-TxRate TxRate-83456k 1668
+VALUE KarlNet-TurboCell-TxRate TxRate-83584k 1669
+VALUE KarlNet-TurboCell-TxRate TxRate-83712k 1670
+VALUE KarlNet-TurboCell-TxRate TxRate-83840k 1671
+VALUE KarlNet-TurboCell-TxRate TxRate-83968k 1672
+VALUE KarlNet-TurboCell-TxRate TxRate-84096k 1673
+VALUE KarlNet-TurboCell-TxRate TxRate-84224k 1674
+VALUE KarlNet-TurboCell-TxRate TxRate-84352k 1675
+VALUE KarlNet-TurboCell-TxRate TxRate-84480k 1676
+VALUE KarlNet-TurboCell-TxRate TxRate-84608k 1677
+VALUE KarlNet-TurboCell-TxRate TxRate-84736k 1678
+VALUE KarlNet-TurboCell-TxRate TxRate-84864k 1679
+VALUE KarlNet-TurboCell-TxRate TxRate-84992k 1680
+VALUE KarlNet-TurboCell-TxRate TxRate-85120k 1681
+VALUE KarlNet-TurboCell-TxRate TxRate-85248k 1682
+VALUE KarlNet-TurboCell-TxRate TxRate-85376k 1683
+VALUE KarlNet-TurboCell-TxRate TxRate-85504k 1684
+VALUE KarlNet-TurboCell-TxRate TxRate-85632k 1685
+VALUE KarlNet-TurboCell-TxRate TxRate-85760k 1686
+VALUE KarlNet-TurboCell-TxRate TxRate-85888k 1687
+VALUE KarlNet-TurboCell-TxRate TxRate-86016k 1688
+VALUE KarlNet-TurboCell-TxRate TxRate-86144k 1689
+VALUE KarlNet-TurboCell-TxRate TxRate-86272k 1690
+VALUE KarlNet-TurboCell-TxRate TxRate-86400k 1691
+VALUE KarlNet-TurboCell-TxRate TxRate-86528k 1692
+VALUE KarlNet-TurboCell-TxRate TxRate-86656k 1693
+VALUE KarlNet-TurboCell-TxRate TxRate-86784k 1694
+VALUE KarlNet-TurboCell-TxRate TxRate-86912k 1695
+VALUE KarlNet-TurboCell-TxRate TxRate-87040k 1696
+VALUE KarlNet-TurboCell-TxRate TxRate-87168k 1697
+VALUE KarlNet-TurboCell-TxRate TxRate-87296k 1698
+VALUE KarlNet-TurboCell-TxRate TxRate-87424k 1699
+VALUE KarlNet-TurboCell-TxRate TxRate-87552k 1700
+VALUE KarlNet-TurboCell-TxRate TxRate-87680k 1701
+VALUE KarlNet-TurboCell-TxRate TxRate-87808k 1702
+VALUE KarlNet-TurboCell-TxRate TxRate-87936k 1703
+VALUE KarlNet-TurboCell-TxRate TxRate-88064k 1704
+VALUE KarlNet-TurboCell-TxRate TxRate-88192k 1705
+VALUE KarlNet-TurboCell-TxRate TxRate-88320k 1706
+VALUE KarlNet-TurboCell-TxRate TxRate-88448k 1707
+VALUE KarlNet-TurboCell-TxRate TxRate-88576k 1708
+VALUE KarlNet-TurboCell-TxRate TxRate-88704k 1709
+VALUE KarlNet-TurboCell-TxRate TxRate-88832k 1710
+VALUE KarlNet-TurboCell-TxRate TxRate-88960k 1711
+VALUE KarlNet-TurboCell-TxRate TxRate-89088k 1712
+VALUE KarlNet-TurboCell-TxRate TxRate-89216k 1713
+VALUE KarlNet-TurboCell-TxRate TxRate-89344k 1714
+VALUE KarlNet-TurboCell-TxRate TxRate-89472k 1715
+VALUE KarlNet-TurboCell-TxRate TxRate-89600k 1716
+VALUE KarlNet-TurboCell-TxRate TxRate-89728k 1717
+VALUE KarlNet-TurboCell-TxRate TxRate-89856k 1718
+VALUE KarlNet-TurboCell-TxRate TxRate-89984k 1719
+VALUE KarlNet-TurboCell-TxRate TxRate-90112k 1720
+VALUE KarlNet-TurboCell-TxRate TxRate-90240k 1721
+VALUE KarlNet-TurboCell-TxRate TxRate-90368k 1722
+VALUE KarlNet-TurboCell-TxRate TxRate-90496k 1723
+VALUE KarlNet-TurboCell-TxRate TxRate-90624k 1724
+VALUE KarlNet-TurboCell-TxRate TxRate-90752k 1725
+VALUE KarlNet-TurboCell-TxRate TxRate-90880k 1726
+VALUE KarlNet-TurboCell-TxRate TxRate-91008k 1727
+VALUE KarlNet-TurboCell-TxRate TxRate-91136k 1728
+VALUE KarlNet-TurboCell-TxRate TxRate-91264k 1729
+VALUE KarlNet-TurboCell-TxRate TxRate-91392k 1730
+VALUE KarlNet-TurboCell-TxRate TxRate-91520k 1731
+VALUE KarlNet-TurboCell-TxRate TxRate-91648k 1732
+VALUE KarlNet-TurboCell-TxRate TxRate-91776k 1733
+VALUE KarlNet-TurboCell-TxRate TxRate-91904k 1734
+VALUE KarlNet-TurboCell-TxRate TxRate-92032k 1735
+VALUE KarlNet-TurboCell-TxRate TxRate-92160k 1736
+VALUE KarlNet-TurboCell-TxRate TxRate-92288k 1737
+VALUE KarlNet-TurboCell-TxRate TxRate-92416k 1738
+VALUE KarlNet-TurboCell-TxRate TxRate-92544k 1739
+VALUE KarlNet-TurboCell-TxRate TxRate-92672k 1740
+VALUE KarlNet-TurboCell-TxRate TxRate-92800k 1741
+VALUE KarlNet-TurboCell-TxRate TxRate-92928k 1742
+VALUE KarlNet-TurboCell-TxRate TxRate-93056k 1743
+VALUE KarlNet-TurboCell-TxRate TxRate-93184k 1744
+VALUE KarlNet-TurboCell-TxRate TxRate-93312k 1745
+VALUE KarlNet-TurboCell-TxRate TxRate-93440k 1746
+VALUE KarlNet-TurboCell-TxRate TxRate-93568k 1747
+VALUE KarlNet-TurboCell-TxRate TxRate-93696k 1748
+VALUE KarlNet-TurboCell-TxRate TxRate-93824k 1749
+VALUE KarlNet-TurboCell-TxRate TxRate-93952k 1750
+VALUE KarlNet-TurboCell-TxRate TxRate-94080k 1751
+VALUE KarlNet-TurboCell-TxRate TxRate-94208k 1752
+VALUE KarlNet-TurboCell-TxRate TxRate-94336k 1753
+VALUE KarlNet-TurboCell-TxRate TxRate-94464k 1754
+VALUE KarlNet-TurboCell-TxRate TxRate-94592k 1755
+VALUE KarlNet-TurboCell-TxRate TxRate-94720k 1756
+VALUE KarlNet-TurboCell-TxRate TxRate-94848k 1757
+VALUE KarlNet-TurboCell-TxRate TxRate-94976k 1758
+VALUE KarlNet-TurboCell-TxRate TxRate-95104k 1759
+VALUE KarlNet-TurboCell-TxRate TxRate-95232k 1760
+VALUE KarlNet-TurboCell-TxRate TxRate-95360k 1761
+VALUE KarlNet-TurboCell-TxRate TxRate-95488k 1762
+VALUE KarlNet-TurboCell-TxRate TxRate-95616k 1763
+VALUE KarlNet-TurboCell-TxRate TxRate-95744k 1764
+VALUE KarlNet-TurboCell-TxRate TxRate-95872k 1765
+VALUE KarlNet-TurboCell-TxRate TxRate-96000k 1766
+VALUE KarlNet-TurboCell-TxRate TxRate-96128k 1767
+VALUE KarlNet-TurboCell-TxRate TxRate-96256k 1768
+VALUE KarlNet-TurboCell-TxRate TxRate-96384k 1769
+VALUE KarlNet-TurboCell-TxRate TxRate-96512k 1770
+VALUE KarlNet-TurboCell-TxRate TxRate-96640k 1771
+VALUE KarlNet-TurboCell-TxRate TxRate-96768k 1772
+VALUE KarlNet-TurboCell-TxRate TxRate-96896k 1773
+VALUE KarlNet-TurboCell-TxRate TxRate-97024k 1774
+VALUE KarlNet-TurboCell-TxRate TxRate-97152k 1775
+VALUE KarlNet-TurboCell-TxRate TxRate-97280k 1776
+VALUE KarlNet-TurboCell-TxRate TxRate-97408k 1777
+VALUE KarlNet-TurboCell-TxRate TxRate-97536k 1778
+VALUE KarlNet-TurboCell-TxRate TxRate-97664k 1779
+VALUE KarlNet-TurboCell-TxRate TxRate-97792k 1780
+VALUE KarlNet-TurboCell-TxRate TxRate-97920k 1781
+VALUE KarlNet-TurboCell-TxRate TxRate-98048k 1782
+VALUE KarlNet-TurboCell-TxRate TxRate-98176k 1783
+VALUE KarlNet-TurboCell-TxRate TxRate-98304k 1784
+VALUE KarlNet-TurboCell-TxRate TxRate-98432k 1785
+VALUE KarlNet-TurboCell-TxRate TxRate-98560k 1786
+VALUE KarlNet-TurboCell-TxRate TxRate-98688k 1787
+VALUE KarlNet-TurboCell-TxRate TxRate-98816k 1788
+VALUE KarlNet-TurboCell-TxRate TxRate-98944k 1789
+VALUE KarlNet-TurboCell-TxRate TxRate-99072k 1790
+VALUE KarlNet-TurboCell-TxRate TxRate-99200k 1791
+VALUE KarlNet-TurboCell-TxRate TxRate-99328k 1792
+VALUE KarlNet-TurboCell-TxRate TxRate-99456k 1793
+VALUE KarlNet-TurboCell-TxRate TxRate-99584k 1794
+VALUE KarlNet-TurboCell-TxRate TxRate-99712k 1795
+VALUE KarlNet-TurboCell-TxRate TxRate-99840k 1796
+VALUE KarlNet-TurboCell-TxRate TxRate-99968k 1797
+VALUE KarlNet-TurboCell-TxRate TxRate-100096k 1798
+VALUE KarlNet-TurboCell-TxRate TxRate-100224k 1799
+VALUE KarlNet-TurboCell-TxRate TxRate-100352k 1800
+VALUE KarlNet-TurboCell-TxRate TxRate-100480k 1801
+VALUE KarlNet-TurboCell-TxRate TxRate-100608k 1802
+VALUE KarlNet-TurboCell-TxRate TxRate-100736k 1803
+VALUE KarlNet-TurboCell-TxRate TxRate-100864k 1804
+VALUE KarlNet-TurboCell-TxRate TxRate-100992k 1805
+VALUE KarlNet-TurboCell-TxRate TxRate-101120k 1806
+VALUE KarlNet-TurboCell-TxRate TxRate-101248k 1807
+VALUE KarlNet-TurboCell-TxRate TxRate-101376k 1808
+VALUE KarlNet-TurboCell-TxRate TxRate-101504k 1809
+VALUE KarlNet-TurboCell-TxRate TxRate-101632k 1810
+VALUE KarlNet-TurboCell-TxRate TxRate-101760k 1811
+VALUE KarlNet-TurboCell-TxRate TxRate-101888k 1812
+VALUE KarlNet-TurboCell-TxRate TxRate-102016k 1813
+VALUE KarlNet-TurboCell-TxRate TxRate-102144k 1814
+VALUE KarlNet-TurboCell-TxRate TxRate-102272k 1815
+VALUE KarlNet-TurboCell-TxRate TxRate-102400k 1816
+VALUE KarlNet-TurboCell-TxRate TxRate-102528k 1817
+VALUE KarlNet-TurboCell-TxRate TxRate-102656k 1818
+VALUE KarlNet-TurboCell-TxRate TxRate-102784k 1819
+VALUE KarlNet-TurboCell-TxRate TxRate-102912k 1820
+VALUE KarlNet-TurboCell-TxRate TxRate-103040k 1821
+VALUE KarlNet-TurboCell-TxRate TxRate-103168k 1822
+VALUE KarlNet-TurboCell-TxRate TxRate-103296k 1823
+VALUE KarlNet-TurboCell-TxRate TxRate-103424k 1824
+VALUE KarlNet-TurboCell-TxRate TxRate-103552k 1825
+VALUE KarlNet-TurboCell-TxRate TxRate-103680k 1826
+VALUE KarlNet-TurboCell-TxRate TxRate-103808k 1827
+VALUE KarlNet-TurboCell-TxRate TxRate-103936k 1828
+VALUE KarlNet-TurboCell-TxRate TxRate-104064k 1829
+VALUE KarlNet-TurboCell-TxRate TxRate-104192k 1830
+VALUE KarlNet-TurboCell-TxRate TxRate-104320k 1831
+VALUE KarlNet-TurboCell-TxRate TxRate-104448k 1832
+VALUE KarlNet-TurboCell-TxRate TxRate-104576k 1833
+VALUE KarlNet-TurboCell-TxRate TxRate-104704k 1834
+VALUE KarlNet-TurboCell-TxRate TxRate-104832k 1835
+VALUE KarlNet-TurboCell-TxRate TxRate-104960k 1836
+VALUE KarlNet-TurboCell-TxRate TxRate-105088k 1837
+VALUE KarlNet-TurboCell-TxRate TxRate-105216k 1838
+VALUE KarlNet-TurboCell-TxRate TxRate-105344k 1839
+VALUE KarlNet-TurboCell-TxRate TxRate-105472k 1840
+VALUE KarlNet-TurboCell-TxRate TxRate-105600k 1841
+VALUE KarlNet-TurboCell-TxRate TxRate-105728k 1842
+VALUE KarlNet-TurboCell-TxRate TxRate-105856k 1843
+VALUE KarlNet-TurboCell-TxRate TxRate-105984k 1844
+VALUE KarlNet-TurboCell-TxRate TxRate-106112k 1845
+VALUE KarlNet-TurboCell-TxRate TxRate-106240k 1846
+VALUE KarlNet-TurboCell-TxRate TxRate-106368k 1847
+VALUE KarlNet-TurboCell-TxRate TxRate-106496k 1848
+VALUE KarlNet-TurboCell-TxRate TxRate-106624k 1849
+VALUE KarlNet-TurboCell-TxRate TxRate-106752k 1850
+VALUE KarlNet-TurboCell-TxRate TxRate-106880k 1851
+VALUE KarlNet-TurboCell-TxRate TxRate-107008k 1852
+VALUE KarlNet-TurboCell-TxRate TxRate-107136k 1853
+VALUE KarlNet-TurboCell-TxRate TxRate-107264k 1854
+VALUE KarlNet-TurboCell-TxRate TxRate-107392k 1855
+VALUE KarlNet-TurboCell-TxRate TxRate-107520k 1856
+VALUE KarlNet-TurboCell-TxRate TxRate-107648k 1857
+VALUE KarlNet-TurboCell-TxRate TxRate-107776k 1858
+VALUE KarlNet-TurboCell-TxRate TxRate-107904k 1859
+VALUE KarlNet-TurboCell-TxRate TxRate-108032k 1860
+VALUE KarlNet-TurboCell-TxRate TxRate-108160k 1861
+VALUE KarlNet-TurboCell-TxRate TxRate-108288k 1862
+VALUE KarlNet-TurboCell-TxRate TxRate-108416k 1863
+VALUE KarlNet-TurboCell-TxRate TxRate-108544k 1864
+VALUE KarlNet-TurboCell-TxRate TxRate-108672k 1865
+VALUE KarlNet-TurboCell-TxRate TxRate-108800k 1866
+VALUE KarlNet-TurboCell-TxRate TxRate-108928k 1867
+VALUE KarlNet-TurboCell-TxRate TxRate-109056k 1868
+VALUE KarlNet-TurboCell-TxRate TxRate-109184k 1869
+VALUE KarlNet-TurboCell-TxRate TxRate-109312k 1870
+VALUE KarlNet-TurboCell-TxRate TxRate-109440k 1871
+VALUE KarlNet-TurboCell-TxRate TxRate-109568k 1872
+VALUE KarlNet-TurboCell-TxRate TxRate-109696k 1873
+VALUE KarlNet-TurboCell-TxRate TxRate-109824k 1874
+VALUE KarlNet-TurboCell-TxRate TxRate-109952k 1875
+VALUE KarlNet-TurboCell-TxRate TxRate-110080k 1876
+VALUE KarlNet-TurboCell-TxRate TxRate-110208k 1877
+VALUE KarlNet-TurboCell-TxRate TxRate-110336k 1878
+VALUE KarlNet-TurboCell-TxRate TxRate-110464k 1879
+VALUE KarlNet-TurboCell-TxRate TxRate-110592k 1880
+VALUE KarlNet-TurboCell-TxRate TxRate-110720k 1881
+VALUE KarlNet-TurboCell-TxRate TxRate-110848k 1882
+VALUE KarlNet-TurboCell-TxRate TxRate-110976k 1883
+VALUE KarlNet-TurboCell-TxRate TxRate-111104k 1884
+VALUE KarlNet-TurboCell-TxRate TxRate-111232k 1885
+VALUE KarlNet-TurboCell-TxRate TxRate-111360k 1886
+VALUE KarlNet-TurboCell-TxRate TxRate-111488k 1887
+VALUE KarlNet-TurboCell-TxRate TxRate-111616k 1888
+VALUE KarlNet-TurboCell-TxRate TxRate-111744k 1889
+VALUE KarlNet-TurboCell-TxRate TxRate-111872k 1890
+VALUE KarlNet-TurboCell-TxRate TxRate-112000k 1891
+VALUE KarlNet-TurboCell-TxRate TxRate-112128k 1892
+VALUE KarlNet-TurboCell-TxRate TxRate-112256k 1893
+VALUE KarlNet-TurboCell-TxRate TxRate-112384k 1894
+VALUE KarlNet-TurboCell-TxRate TxRate-112512k 1895
+VALUE KarlNet-TurboCell-TxRate TxRate-112640k 1896
+VALUE KarlNet-TurboCell-TxRate TxRate-112768k 1897
+VALUE KarlNet-TurboCell-TxRate TxRate-112896k 1898
+VALUE KarlNet-TurboCell-TxRate TxRate-113024k 1899
+VALUE KarlNet-TurboCell-TxRate TxRate-113152k 1900
+VALUE KarlNet-TurboCell-TxRate TxRate-113280k 1901
+VALUE KarlNet-TurboCell-TxRate TxRate-113408k 1902
+VALUE KarlNet-TurboCell-TxRate TxRate-113536k 1903
+VALUE KarlNet-TurboCell-TxRate TxRate-113664k 1904
+VALUE KarlNet-TurboCell-TxRate TxRate-113792k 1905
+VALUE KarlNet-TurboCell-TxRate TxRate-113920k 1906
+VALUE KarlNet-TurboCell-TxRate TxRate-114048k 1907
+VALUE KarlNet-TurboCell-TxRate TxRate-114176k 1908
+VALUE KarlNet-TurboCell-TxRate TxRate-114304k 1909
+VALUE KarlNet-TurboCell-TxRate TxRate-114432k 1910
+VALUE KarlNet-TurboCell-TxRate TxRate-114560k 1911
+VALUE KarlNet-TurboCell-TxRate TxRate-114688k 1912
+VALUE KarlNet-TurboCell-TxRate TxRate-114816k 1913
+VALUE KarlNet-TurboCell-TxRate TxRate-114944k 1914
+VALUE KarlNet-TurboCell-TxRate TxRate-115072k 1915
+VALUE KarlNet-TurboCell-TxRate TxRate-115200k 1916
+VALUE KarlNet-TurboCell-TxRate TxRate-115328k 1917
+VALUE KarlNet-TurboCell-TxRate TxRate-115456k 1918
+VALUE KarlNet-TurboCell-TxRate TxRate-115584k 1919
+VALUE KarlNet-TurboCell-TxRate TxRate-115712k 1920
+VALUE KarlNet-TurboCell-TxRate TxRate-115840k 1921
+VALUE KarlNet-TurboCell-TxRate TxRate-115968k 1922
+VALUE KarlNet-TurboCell-TxRate TxRate-116096k 1923
+VALUE KarlNet-TurboCell-TxRate TxRate-116224k 1924
+VALUE KarlNet-TurboCell-TxRate TxRate-116352k 1925
+VALUE KarlNet-TurboCell-TxRate TxRate-116480k 1926
+VALUE KarlNet-TurboCell-TxRate TxRate-116608k 1927
+VALUE KarlNet-TurboCell-TxRate TxRate-116736k 1928
+VALUE KarlNet-TurboCell-TxRate TxRate-116864k 1929
+VALUE KarlNet-TurboCell-TxRate TxRate-116992k 1930
+VALUE KarlNet-TurboCell-TxRate TxRate-117120k 1931
+VALUE KarlNet-TurboCell-TxRate TxRate-117248k 1932
+VALUE KarlNet-TurboCell-TxRate TxRate-117376k 1933
+VALUE KarlNet-TurboCell-TxRate TxRate-117504k 1934
+VALUE KarlNet-TurboCell-TxRate TxRate-117632k 1935
+VALUE KarlNet-TurboCell-TxRate TxRate-117760k 1936
+VALUE KarlNet-TurboCell-TxRate TxRate-117888k 1937
+VALUE KarlNet-TurboCell-TxRate TxRate-118016k 1938
+VALUE KarlNet-TurboCell-TxRate TxRate-118144k 1939
+VALUE KarlNet-TurboCell-TxRate TxRate-118272k 1940
+VALUE KarlNet-TurboCell-TxRate TxRate-118400k 1941
+VALUE KarlNet-TurboCell-TxRate TxRate-118528k 1942
+VALUE KarlNet-TurboCell-TxRate TxRate-118656k 1943
+VALUE KarlNet-TurboCell-TxRate TxRate-118784k 1944
+VALUE KarlNet-TurboCell-TxRate TxRate-118912k 1945
+VALUE KarlNet-TurboCell-TxRate TxRate-119040k 1946
+VALUE KarlNet-TurboCell-TxRate TxRate-119168k 1947
+VALUE KarlNet-TurboCell-TxRate TxRate-119296k 1948
+VALUE KarlNet-TurboCell-TxRate TxRate-119424k 1949
+VALUE KarlNet-TurboCell-TxRate TxRate-119552k 1950
+VALUE KarlNet-TurboCell-TxRate TxRate-119680k 1951
+VALUE KarlNet-TurboCell-TxRate TxRate-119808k 1952
+VALUE KarlNet-TurboCell-TxRate TxRate-119936k 1953
+VALUE KarlNet-TurboCell-TxRate TxRate-120064k 1954
+VALUE KarlNet-TurboCell-TxRate TxRate-120192k 1955
+VALUE KarlNet-TurboCell-TxRate TxRate-120320k 1956
+VALUE KarlNet-TurboCell-TxRate TxRate-120448k 1957
+VALUE KarlNet-TurboCell-TxRate TxRate-120576k 1958
+VALUE KarlNet-TurboCell-TxRate TxRate-120704k 1959
+VALUE KarlNet-TurboCell-TxRate TxRate-120832k 1960
+VALUE KarlNet-TurboCell-TxRate TxRate-120960k 1961
+VALUE KarlNet-TurboCell-TxRate TxRate-121088k 1962
+VALUE KarlNet-TurboCell-TxRate TxRate-121216k 1963
+VALUE KarlNet-TurboCell-TxRate TxRate-121344k 1964
+VALUE KarlNet-TurboCell-TxRate TxRate-121472k 1965
+VALUE KarlNet-TurboCell-TxRate TxRate-121600k 1966
+VALUE KarlNet-TurboCell-TxRate TxRate-121728k 1967
+VALUE KarlNet-TurboCell-TxRate TxRate-121856k 1968
+VALUE KarlNet-TurboCell-TxRate TxRate-121984k 1969
+VALUE KarlNet-TurboCell-TxRate TxRate-122112k 1970
+VALUE KarlNet-TurboCell-TxRate TxRate-122240k 1971
+VALUE KarlNet-TurboCell-TxRate TxRate-122368k 1972
+VALUE KarlNet-TurboCell-TxRate TxRate-122496k 1973
+VALUE KarlNet-TurboCell-TxRate TxRate-122624k 1974
+VALUE KarlNet-TurboCell-TxRate TxRate-122752k 1975
+VALUE KarlNet-TurboCell-TxRate TxRate-122880k 1976
+VALUE KarlNet-TurboCell-TxRate TxRate-123008k 1977
+VALUE KarlNet-TurboCell-TxRate TxRate-123136k 1978
+VALUE KarlNet-TurboCell-TxRate TxRate-123264k 1979
+VALUE KarlNet-TurboCell-TxRate TxRate-123392k 1980
+VALUE KarlNet-TurboCell-TxRate TxRate-123520k 1981
+VALUE KarlNet-TurboCell-TxRate TxRate-123648k 1982
+VALUE KarlNet-TurboCell-TxRate TxRate-123776k 1983
+VALUE KarlNet-TurboCell-TxRate TxRate-123904k 1984
+VALUE KarlNet-TurboCell-TxRate TxRate-124032k 1985
+VALUE KarlNet-TurboCell-TxRate TxRate-124160k 1986
+VALUE KarlNet-TurboCell-TxRate TxRate-124288k 1987
+VALUE KarlNet-TurboCell-TxRate TxRate-124416k 1988
+VALUE KarlNet-TurboCell-TxRate TxRate-124544k 1989
+VALUE KarlNet-TurboCell-TxRate TxRate-124672k 1990
+VALUE KarlNet-TurboCell-TxRate TxRate-124800k 1991
+VALUE KarlNet-TurboCell-TxRate TxRate-124928k 1992
+VALUE KarlNet-TurboCell-TxRate TxRate-125056k 1993
+VALUE KarlNet-TurboCell-TxRate TxRate-125184k 1994
+VALUE KarlNet-TurboCell-TxRate TxRate-125312k 1995
+VALUE KarlNet-TurboCell-TxRate TxRate-125440k 1996
+VALUE KarlNet-TurboCell-TxRate TxRate-125568k 1997
+VALUE KarlNet-TurboCell-TxRate TxRate-125696k 1998
+VALUE KarlNet-TurboCell-TxRate TxRate-125824k 1999
+VALUE KarlNet-TurboCell-TxRate TxRate-125952k 2000
+VALUE KarlNet-TurboCell-TxRate TxRate-126080k 2001
+VALUE KarlNet-TurboCell-TxRate TxRate-126208k 2002
+VALUE KarlNet-TurboCell-TxRate TxRate-126336k 2003
+VALUE KarlNet-TurboCell-TxRate TxRate-126464k 2004
+VALUE KarlNet-TurboCell-TxRate TxRate-126592k 2005
+VALUE KarlNet-TurboCell-TxRate TxRate-126720k 2006
+VALUE KarlNet-TurboCell-TxRate TxRate-126848k 2007
+VALUE KarlNet-TurboCell-TxRate TxRate-126976k 2008
+VALUE KarlNet-TurboCell-TxRate TxRate-127104k 2009
+VALUE KarlNet-TurboCell-TxRate TxRate-127232k 2010
+VALUE KarlNet-TurboCell-TxRate TxRate-127360k 2011
+VALUE KarlNet-TurboCell-TxRate TxRate-127488k 2012
+VALUE KarlNet-TurboCell-TxRate TxRate-127616k 2013
+VALUE KarlNet-TurboCell-TxRate TxRate-127744k 2014
+VALUE KarlNet-TurboCell-TxRate TxRate-127872k 2015
+VALUE KarlNet-TurboCell-TxRate TxRate-128000k 2016
+VALUE KarlNet-TurboCell-TxRate TxRate-128128k 2017
+VALUE KarlNet-TurboCell-TxRate TxRate-128256k 2018
+VALUE KarlNet-TurboCell-TxRate TxRate-128384k 2019
+VALUE KarlNet-TurboCell-TxRate TxRate-128512k 2020
+VALUE KarlNet-TurboCell-TxRate TxRate-128640k 2021
+VALUE KarlNet-TurboCell-TxRate TxRate-128768k 2022
+VALUE KarlNet-TurboCell-TxRate TxRate-128896k 2023
+VALUE KarlNet-TurboCell-TxRate TxRate-129024k 2024
+VALUE KarlNet-TurboCell-TxRate TxRate-129152k 2025
+VALUE KarlNet-TurboCell-TxRate TxRate-129280k 2026
+VALUE KarlNet-TurboCell-TxRate TxRate-129408k 2027
+VALUE KarlNet-TurboCell-TxRate TxRate-129536k 2028
+VALUE KarlNet-TurboCell-TxRate TxRate-129664k 2029
+VALUE KarlNet-TurboCell-TxRate TxRate-129792k 2030
+VALUE KarlNet-TurboCell-TxRate TxRate-129920k 2031
+VALUE KarlNet-TurboCell-TxRate TxRate-130048k 2032
+VALUE KarlNet-TurboCell-TxRate TxRate-130176k 2033
+VALUE KarlNet-TurboCell-TxRate TxRate-130304k 2034
+VALUE KarlNet-TurboCell-TxRate TxRate-130432k 2035
+VALUE KarlNet-TurboCell-TxRate TxRate-130560k 2036
+VALUE KarlNet-TurboCell-TxRate TxRate-130688k 2037
+VALUE KarlNet-TurboCell-TxRate TxRate-130816k 2038
+VALUE KarlNet-TurboCell-TxRate TxRate-130944k 2039
+VALUE KarlNet-TurboCell-TxRate TxRate-131072k 2040
+VALUE KarlNet-TurboCell-TxRate TxRate-131200k 2041
+VALUE KarlNet-TurboCell-TxRate TxRate-131328k 2042
+VALUE KarlNet-TurboCell-TxRate TxRate-131456k 2043
+VALUE KarlNet-TurboCell-TxRate TxRate-131584k 2044
+VALUE KarlNet-TurboCell-TxRate TxRate-131712k 2045
+VALUE KarlNet-TurboCell-TxRate TxRate-131840k 2046
+VALUE KarlNet-TurboCell-TxRate TxRate-131968k 2047
+
+# Sets the remote client's Operating State
+ATTRIBUTE KarlNet-TurboCell-OpState 153 integer
+VALUE KarlNet-TurboCell-OpState Up 0
+VALUE KarlNet-TurboCell-OpState Down 1
+
+# Sets the remote client's Operating Mode
+ATTRIBUTE KarlNet-TurboCell-OpMode 154 integer
+VALUE KarlNet-TurboCell-OpMode Peer-to-Peer 0
+VALUE KarlNet-TurboCell-OpMode Base 1
+VALUE KarlNet-TurboCell-OpMode Base-Polling 2
+VALUE KarlNet-TurboCell-OpMode Satellite-NT 3
+
+# ----------------------------------------------
+# END OF KarlNet Vendor-specific information
+# ----------------------------------------------
+
+END-VENDOR KarlNet
+# -*- text -*-
#
# Vendor-Specific attributes use the SMI Network Management Private
# Enterprise Code from the "Assigned Numbers" RFC
#
-VENDOR Livingston 307
+VENDOR Livingston 307
#
# Livingston Vendor-Specific Attributes (requires ComOS 3.8)
#
-ATTRIBUTE LE-Terminate-Detail 2 string Livingston
-ATTRIBUTE LE-Advice-of-Charge 3 string Livingston
-ATTRIBUTE LE-Connect-Detail 4 string Livingston
-
-ATTRIBUTE LE-IP-Pool 6 string Livingston
-ATTRIBUTE LE-IP-Gateway 7 ipaddr Livingston
-ATTRIBUTE LE-Modem-Info 8 string Livingston
-ATTRIBUTE LE-IPSec-Log-Options 9 integer Livingston
-ATTRIBUTE LE-IPSec-Deny-Action 10 integer Livingston
-ATTRIBUTE LE-IPSec-Active-Profile 11 string Livingston
-ATTRIBUTE LE-IPSec-Outsource-Profile 12 string Livingston
-ATTRIBUTE LE-IPSec-Passive-Profile 13 string Livingston
-ATTRIBUTE LE-NAT-TCP-Session-Timeout 14 integer Livingston
-ATTRIBUTE LE-NAT-Other-Session-Timeout 15 integer Livingston
-ATTRIBUTE LE-NAT-Log-Options 16 integer Livingston
-ATTRIBUTE LE-NAT-Sess-Dir-Fail-Action 17 integer Livingston
-ATTRIBUTE LE-NAT-Inmap 18 string Livingston
-ATTRIBUTE LE-NAT-Outmap 19 string Livingston
-ATTRIBUTE LE-NAT-Outsource-Inmap 20 string Livingston
-ATTRIBUTE LE-NAT-Outsource-Outmap 21 string Livingston
-ATTRIBUTE LE-Admin-Group 22 string Livingston
-ATTRIBUTE LE-Multicast-Client 23 integer Livingston
-
-VALUE LE-IPSec-Deny-Action Drop 1
-VALUE LE-IPSec-Deny-Action ICMP-Reject 2
-VALUE LE-IPSec-Deny-Action Pass-Through 3
-
-VALUE LE-IPSec-Log-Options SA-Success-On 1
-VALUE LE-IPSec-Log-Options SA-Failure-On 2
-VALUE LE-IPSec-Log-Options Console-On 3
-VALUE LE-IPSec-Log-Options Syslog-On 4
-VALUE LE-IPSec-Log-Options SA-Success-Off 5
-VALUE LE-IPSec-Log-Options SA-Failure-Off 6
-VALUE LE-IPSec-Log-Options Console-Off 7
-VALUE LE-IPSec-Log-Options Syslog-Off 8
-
-VALUE LE-NAT-Sess-Dir-Fail-Action Drop 1
-VALUE LE-NAT-Sess-Dir-Fail-Action ICMP-Reject 2
-VALUE LE-NAT-Sess-Dir-Fail-Action Pass-Through 3
-
-VALUE LE-NAT-Log-Options Session-Success-On 1
-VALUE LE-NAT-Log-Options Session-Failure-On 2
-VALUE LE-NAT-Log-Options Console-On 3
-VALUE LE-NAT-Log-Options Syslog-On 4
-VALUE LE-NAT-Log-Options Success-Off 5
-VALUE LE-NAT-Log-Options Failure-Off 6
-VALUE LE-NAT-Log-Options Console-Off 7
-VALUE LE-NAT-Log-Options Syslog-Off 8
-
-VALUE LE-Multicast-Client On 1
+BEGIN-VENDOR Livingston
+
+ATTRIBUTE LE-Terminate-Detail 2 string
+ATTRIBUTE LE-Advice-of-Charge 3 string
+ATTRIBUTE LE-Connect-Detail 4 string
+
+ATTRIBUTE LE-IP-Pool 6 string
+ATTRIBUTE LE-IP-Gateway 7 ipaddr
+ATTRIBUTE LE-Modem-Info 8 string
+ATTRIBUTE LE-IPSec-Log-Options 9 integer
+ATTRIBUTE LE-IPSec-Deny-Action 10 integer
+ATTRIBUTE LE-IPSec-Active-Profile 11 string
+ATTRIBUTE LE-IPSec-Outsource-Profile 12 string
+ATTRIBUTE LE-IPSec-Passive-Profile 13 string
+ATTRIBUTE LE-NAT-TCP-Session-Timeout 14 integer
+ATTRIBUTE LE-NAT-Other-Session-Timeout 15 integer
+ATTRIBUTE LE-NAT-Log-Options 16 integer
+ATTRIBUTE LE-NAT-Sess-Dir-Fail-Action 17 integer
+ATTRIBUTE LE-NAT-Inmap 18 string
+ATTRIBUTE LE-NAT-Outmap 19 string
+ATTRIBUTE LE-NAT-Outsource-Inmap 20 string
+ATTRIBUTE LE-NAT-Outsource-Outmap 21 string
+ATTRIBUTE LE-Admin-Group 22 string
+ATTRIBUTE LE-Multicast-Client 23 integer
+
+VALUE LE-IPSec-Deny-Action Drop 1
+VALUE LE-IPSec-Deny-Action ICMP-Reject 2
+VALUE LE-IPSec-Deny-Action Pass-Through 3
+
+VALUE LE-IPSec-Log-Options SA-Success-On 1
+VALUE LE-IPSec-Log-Options SA-Failure-On 2
+VALUE LE-IPSec-Log-Options Console-On 3
+VALUE LE-IPSec-Log-Options Syslog-On 4
+VALUE LE-IPSec-Log-Options SA-Success-Off 5
+VALUE LE-IPSec-Log-Options SA-Failure-Off 6
+VALUE LE-IPSec-Log-Options Console-Off 7
+VALUE LE-IPSec-Log-Options Syslog-Off 8
+
+VALUE LE-NAT-Sess-Dir-Fail-Action Drop 1
+VALUE LE-NAT-Sess-Dir-Fail-Action ICMP-Reject 2
+VALUE LE-NAT-Sess-Dir-Fail-Action Pass-Through 3
+
+VALUE LE-NAT-Log-Options Session-Success-On 1
+VALUE LE-NAT-Log-Options Session-Failure-On 2
+VALUE LE-NAT-Log-Options Console-On 3
+VALUE LE-NAT-Log-Options Syslog-On 4
+VALUE LE-NAT-Log-Options Success-Off 5
+VALUE LE-NAT-Log-Options Failure-Off 6
+VALUE LE-NAT-Log-Options Console-Off 7
+VALUE LE-NAT-Log-Options Syslog-Off 8
+
+VALUE LE-Multicast-Client On 1
+
+END-VENDOR Livingston
+# -*- text -*-
##############################################################################
#
# Local-Web Accesspoints
#
##############################################################################
-VENDOR Local-Web 19220
+VENDOR Local-Web 19220
-ATTRIBUTE Local-Web-Client-Ip 192 string Local-Web
-ATTRIBUTE Local-Web-Border-Router 193 string Local-Web
+BEGIN-VENDOR Local-Web
-ATTRIBUTE Local-Web-Tx-Limit 200 integer Local-Web
-ATTRIBUTE Local-Web-Rx-Limit 201 integer Local-Web
+ATTRIBUTE Local-Web-Client-Ip 192 string
+ATTRIBUTE Local-Web-Border-Router 193 string
-ATTRIBUTE Local-Web-Acct-Time 210 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Duration 211 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Tx-Bytes 212 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Rx-Bytes 213 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Tx-Gigawords 214 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Rx-Gigawords 215 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Tx-Mgmt 216 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Interim-Rx-Mgmt 217 integer Local-Web
+ATTRIBUTE Local-Web-Tx-Limit 200 integer
+ATTRIBUTE Local-Web-Rx-Limit 201 integer
-ATTRIBUTE Local-Web-Acct-Tx-Mgmt 230 integer Local-Web
-ATTRIBUTE Local-Web-Acct-Rx-Mgmt 231 integer Local-Web
+ATTRIBUTE Local-Web-Acct-Time 210 integer
+ATTRIBUTE Local-Web-Acct-Duration 211 integer
+ATTRIBUTE Local-Web-Acct-Interim-Tx-Bytes 212 integer
+ATTRIBUTE Local-Web-Acct-Interim-Rx-Bytes 213 integer
+ATTRIBUTE Local-Web-Acct-Interim-Tx-Gigawords 214 integer
+ATTRIBUTE Local-Web-Acct-Interim-Rx-Gigawords 215 integer
+ATTRIBUTE Local-Web-Acct-Interim-Tx-Mgmt 216 integer
+ATTRIBUTE Local-Web-Acct-Interim-Rx-Mgmt 217 integer
-ATTRIBUTE Local-Web-Reauth-Counter 240 integer Local-Web
+ATTRIBUTE Local-Web-Acct-Tx-Mgmt 230 integer
+ATTRIBUTE Local-Web-Acct-Rx-Mgmt 231 integer
+
+ATTRIBUTE Local-Web-Reauth-Counter 240 integer
+
+END-VENDOR Local-Web
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Lucent VSAs, in their own "magic" 16-bit format.
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Lucent 4846 format=2,1
+
+BEGIN-VENDOR Lucent
+
+ATTRIBUTE Lucent-Max-Shared-Users 2 integer
+ATTRIBUTE Lucent-IP-DSCP 3 integer
+ATTRIBUTE Lucent-X25-X121-Source-Address 4 string
+ATTRIBUTE Lucent-PPP-Circuit 5 integer
+ATTRIBUTE Lucent-PPP-Circuit-Name 6 string
+ATTRIBUTE Lucent-UU-Info 7 string
+ATTRIBUTE Lucent-User-Priority 8 integer
+ATTRIBUTE Lucent-CIR-Timer 9 integer
+ATTRIBUTE Lucent-FR-08-Mode 10 integer
+ATTRIBUTE Lucent-Destination-NAS-Port 11 integer
+ATTRIBUTE Lucent-FR-SVC-Addr 12 string
+ATTRIBUTE Lucent-NAS-Port-Format 13 integer
+ATTRIBUTE Lucent-ATM-Fault-Management 14 integer
+ATTRIBUTE Lucent-ATM-Loopback-Cell-Loss 15 integer
+ATTRIBUTE Lucent-Ckt-Type 16 integer
+ATTRIBUTE Lucent-SVC-Enabled 17 integer
+ATTRIBUTE Lucent-Session-Type 18 integer
+ATTRIBUTE Lucent-H323-Gatekeeper 19 ipaddr
+ATTRIBUTE Lucent-Global-Call-Id 20 string
+ATTRIBUTE Lucent-H323-Conference-Id 21 integer
+ATTRIBUTE Lucent-H323-Destination-NAS-ID 22 ipaddr
+ATTRIBUTE Lucent-H323-Dialed-Time 23 integer
+ATTRIBUTE Lucent-Dialed-Number 24 string
+ATTRIBUTE Lucent-Inter-Arrival-Jitter 25 integer
+ATTRIBUTE Lucent-Dropped-Octets 26 integer
+ATTRIBUTE Lucent-Dropped-Packets 27 integer
+ATTRIBUTE Lucent-Auth-Delay 28 integer
+ATTRIBUTE Lucent-X25-Pad-X3-Profile 29 integer
+ATTRIBUTE Lucent-X25-Pad-X3-Parameters 30 string
+ATTRIBUTE Lucent-Tunnel-VRouter-Name 31 string
+ATTRIBUTE Lucent-X25-Reverse-Charging 32 integer
+ATTRIBUTE Lucent-X25-Nui-Prompt 33 string
+ATTRIBUTE Lucent-X25-Nui-Password-Prompt 34 string
+ATTRIBUTE Lucent-X25-Cug 35 string
+ATTRIBUTE Lucent-X25-Pad-Alias-1 36 string
+ATTRIBUTE Lucent-X25-Pad-Alias-2 37 string
+ATTRIBUTE Lucent-X25-Pad-Alias-3 38 string
+ATTRIBUTE Lucent-X25-X121-Address 39 string
+ATTRIBUTE Lucent-X25-Nui 40 string
+ATTRIBUTE Lucent-X25-Rpoa 41 string
+ATTRIBUTE Lucent-X25-Pad-Prompt 42 string
+ATTRIBUTE Lucent-X25-Pad-Banner 43 string
+ATTRIBUTE Lucent-X25-Profile-Name 44 string
+ATTRIBUTE Lucent-Recv-Name 45 string
+ATTRIBUTE Lucent-Bi-Directional-Auth 46 integer
+ATTRIBUTE Lucent-MTU 47 integer
+ATTRIBUTE Lucent-Call-Direction 48 integer
+ATTRIBUTE Lucent-Service-Type 49 integer
+ATTRIBUTE Lucent-Filter-Required 50 integer
+ATTRIBUTE Lucent-Traffic-Shaper 51 integer
+ATTRIBUTE Lucent-Access-Intercept-LEA 52 string
+ATTRIBUTE Lucent-Access-Intercept-Log 53 string
+ATTRIBUTE Lucent-Private-Route-Table-ID 54 string
+ATTRIBUTE Lucent-Private-Route-Required 55 integer
+ATTRIBUTE Lucent-Cache-Refresh 56 integer
+ATTRIBUTE Lucent-Cache-Time 57 integer
+ATTRIBUTE Lucent-Egress-Enabled 58 integer
+ATTRIBUTE Lucent-QOS-Upstream 59 string
+ATTRIBUTE Lucent-QOS-Downstream 60 string
+ATTRIBUTE Lucent-ATM-Connect-Vpi 61 integer
+ATTRIBUTE Lucent-ATM-Connect-Vci 62 integer
+ATTRIBUTE Lucent-ATM-Connect-Group 63 integer
+ATTRIBUTE Lucent-ATM-Group 64 integer
+ATTRIBUTE Lucent-IPX-Header-Compression 65 integer
+ATTRIBUTE Lucent-Calling-Id-Type-Of-Number 66 integer
+ATTRIBUTE Lucent-Calling-Id-Numbering-Plan 67 integer
+ATTRIBUTE Lucent-Calling-Id-Presentation 68 integer
+ATTRIBUTE Lucent-Calling-Id-Screening 69 integer
+ATTRIBUTE Lucent-BIR-Enable 70 integer
+ATTRIBUTE Lucent-BIR-Proxy 71 integer
+ATTRIBUTE Lucent-BIR-Bridge-Group 72 integer
+ATTRIBUTE Lucent-IPSEC-Profile 73 string
+ATTRIBUTE Lucent-PPPoE-Enable 74 integer
+ATTRIBUTE Lucent-Bridge-Non-PPPoE 75 integer
+ATTRIBUTE Lucent-ATM-Direct 76 integer
+ATTRIBUTE Lucent-ATM-Direct-Profile 77 string
+ATTRIBUTE Lucent-Client-Primary-WINS 78 ipaddr
+ATTRIBUTE Lucent-Client-Secondary-WINS 79 ipaddr
+ATTRIBUTE Lucent-Client-Assign-WINS 80 integer
+ATTRIBUTE Lucent-Auth-Type 81 integer
+ATTRIBUTE Lucent-Port-Redir-Protocol 82 integer
+ATTRIBUTE Lucent-Port-Redir-Portnum 83 integer
+ATTRIBUTE Lucent-Port-Redir-Server 84 ipaddr
+ATTRIBUTE Lucent-IP-Pool-Chaining 85 integer
+ATTRIBUTE Lucent-Owner-IP-Addr 86 ipaddr
+ATTRIBUTE Lucent-IP-TOS 87 integer
+ATTRIBUTE Lucent-IP-TOS-Precedence 88 integer
+ATTRIBUTE Lucent-IP-TOS-Apply-To 89 integer
+ATTRIBUTE Lucent-Filter 90 string
+ATTRIBUTE Lucent-Telnet-Profile 91 string
+ATTRIBUTE Lucent-Dsl-Rate-Type 92 integer
+ATTRIBUTE Lucent-Redirect-Number 93 string
+ATTRIBUTE Lucent-ATM-Vpi 94 integer
+ATTRIBUTE Lucent-ATM-Vci 95 integer
+ATTRIBUTE Lucent-Source-IP-Check 96 integer
+ATTRIBUTE Lucent-Dsl-Rate-Mode 97 integer
+ATTRIBUTE Lucent-Dsl-Upstream-Limit 98 integer
+ATTRIBUTE Lucent-Dsl-Downstream-Limit 99 integer
+ATTRIBUTE Lucent-Dsl-CIR-Recv-Limit 100 integer
+ATTRIBUTE Lucent-Dsl-CIR-Xmit-Limit 101 integer
+ATTRIBUTE Lucent-VRouter-Name 102 string
+ATTRIBUTE Lucent-Source-Auth 103 string
+ATTRIBUTE Lucent-Private-Route 104 string
+ATTRIBUTE Lucent-Numbering-Plan-ID 105 integer
+ATTRIBUTE Lucent-FR-Link-Status-DLCI 106 integer
+ATTRIBUTE Lucent-Calling-Subaddress 107 string
+ATTRIBUTE Lucent-Callback-Delay 108 integer
+ATTRIBUTE Lucent-Endpoint-Disc 109 octets
+ATTRIBUTE Lucent-Remote-FW 110 string
+ATTRIBUTE Lucent-Multicast-GLeave-Delay 111 integer
+ATTRIBUTE Lucent-CBCP-Enable 112 integer
+ATTRIBUTE Lucent-CBCP-Mode 113 integer
+ATTRIBUTE Lucent-CBCP-Delay 114 integer
+ATTRIBUTE Lucent-CBCP-Trunk-Group 115 integer
+ATTRIBUTE Lucent-Appletalk-Route 116 string
+ATTRIBUTE Lucent-Appletalk-Peer-Mode 117 integer
+ATTRIBUTE Lucent-Route-Appletalk 118 integer
+ATTRIBUTE Lucent-FCP-Parameter 119 string
+ATTRIBUTE Lucent-Modem-PortNo 120 integer
+ATTRIBUTE Lucent-Modem-SlotNo 121 integer
+ATTRIBUTE Lucent-Modem-ShelfNo 122 integer
+ATTRIBUTE Lucent-Call-Attempt-Limit 123 integer
+ATTRIBUTE Lucent-Call-Block-Duration 124 integer
+ATTRIBUTE Lucent-Maximum-Call-Duration 125 integer
+ATTRIBUTE Lucent-Route-Preference 126 integer
+ATTRIBUTE Lucent-Tunneling-Protocol 127 integer
+ATTRIBUTE Lucent-Shared-Profile-Enable 128 integer
+ATTRIBUTE Lucent-Primary-Home-Agent 129 string
+ATTRIBUTE Lucent-Secondary-Home-Agent 130 string
+ATTRIBUTE Lucent-Dialout-Allowed 131 integer
+ATTRIBUTE Lucent-Client-Gateway 132 ipaddr
+ATTRIBUTE Lucent-BACP-Enable 133 integer
+ATTRIBUTE Lucent-DHCP-Maximum-Leases 134 integer
+ATTRIBUTE Lucent-Client-Primary-DNS 135 ipaddr
+ATTRIBUTE Lucent-Client-Secondary-DNS 136 ipaddr
+ATTRIBUTE Lucent-Client-Assign-DNS 137 integer
+ATTRIBUTE Lucent-User-Acct-Type 138 integer
+ATTRIBUTE Lucent-User-Acct-Host 139 ipaddr
+ATTRIBUTE Lucent-User-Acct-Port 140 integer
+ATTRIBUTE Lucent-User-Acct-Key 141 string
+ATTRIBUTE Lucent-User-Acct-Base 142 integer
+ATTRIBUTE Lucent-User-Acct-Time 143 integer
+ATTRIBUTE Lucent-Assign-IP-Client 144 ipaddr
+ATTRIBUTE Lucent-Assign-IP-Server 145 ipaddr
+ATTRIBUTE Lucent-Assign-IP-Global-Pool 146 string
+ATTRIBUTE Lucent-DHCP-Reply 147 integer
+ATTRIBUTE Lucent-DHCP-Pool-Number 148 integer
+ATTRIBUTE Lucent-Expect-Callback 149 integer
+ATTRIBUTE Lucent-Event-Type 150 integer
+ATTRIBUTE Lucent-Session-Svr-Key 151 string
+ATTRIBUTE Lucent-Multicast-Rate-Limit 152 integer
+ATTRIBUTE Lucent-IF-Netmask 153 ipaddr
+ATTRIBUTE Lucent-Remote-Addr 154 ipaddr
+ATTRIBUTE Lucent-Multicast-Client 155 integer
+ATTRIBUTE Lucent-FR-Circuit-Name 156 string
+ATTRIBUTE Lucent-FR-LinkUp 157 integer
+ATTRIBUTE Lucent-FR-Nailed-Grp 158 integer
+ATTRIBUTE Lucent-FR-Type 159 integer
+ATTRIBUTE Lucent-FR-Link-Mgt 160 integer
+ATTRIBUTE Lucent-FR-N391 161 integer
+ATTRIBUTE Lucent-FR-DCE-N392 162 integer
+ATTRIBUTE Lucent-FR-DTE-N392 163 integer
+ATTRIBUTE Lucent-FR-DCE-N393 164 integer
+ATTRIBUTE Lucent-FR-DTE-N393 165 integer
+ATTRIBUTE Lucent-FR-T391 166 integer
+ATTRIBUTE Lucent-FR-T392 167 integer
+ATTRIBUTE Lucent-Bridge-Address 168 string
+ATTRIBUTE Lucent-TS-Idle-Limit 169 integer
+ATTRIBUTE Lucent-TS-Idle-Mode 170 integer
+ATTRIBUTE Lucent-DBA-Monitor 171 integer
+ATTRIBUTE Lucent-Base-Channel-Count 172 integer
+ATTRIBUTE Lucent-Minimum-Channels 173 integer
+ATTRIBUTE Lucent-IPX-Route 174 string
+ATTRIBUTE Lucent-FT1-Caller 175 integer
+ATTRIBUTE Lucent-Backup 176 string
+ATTRIBUTE Lucent-Call-Type 177 integer
+ATTRIBUTE Lucent-Group 178 string
+ATTRIBUTE Lucent-FR-DLCI 179 integer
+ATTRIBUTE Lucent-FR-Profile-Name 180 string
+ATTRIBUTE Lucent-Ara-PW 181 string
+ATTRIBUTE Lucent-IPX-Node-Addr 182 string
+ATTRIBUTE Lucent-Home-Agent-IP-Addr 183 ipaddr
+ATTRIBUTE Lucent-Home-Agent-Password 184 string
+ATTRIBUTE Lucent-Home-Network-Name 185 string
+ATTRIBUTE Lucent-Home-Agent-UDP-Port 186 integer
+ATTRIBUTE Lucent-Multilink-ID 187 integer
+ATTRIBUTE Lucent-Num-In-Multilink 188 integer
+ATTRIBUTE Lucent-First-Dest 189 ipaddr
+ATTRIBUTE Lucent-Pre-Input-Octets 190 integer
+ATTRIBUTE Lucent-Pre-Output-Octets 191 integer
+ATTRIBUTE Lucent-Pre-Input-Packets 192 integer
+ATTRIBUTE Lucent-Pre-Output-Packets 193 integer
+ATTRIBUTE Lucent-Maximum-Time 194 integer
+ATTRIBUTE Lucent-Disconnect-Cause 195 integer
+ATTRIBUTE Lucent-Connect-Progress 196 integer
+ATTRIBUTE Lucent-Data-Rate 197 integer
+ATTRIBUTE Lucent-PreSession-Time 198 integer
+ATTRIBUTE Lucent-Token-Idle 199 integer
+ATTRIBUTE Lucent-Token-Immediate 200 integer
+ATTRIBUTE Lucent-Require-Auth 201 integer
+ATTRIBUTE Lucent-Number-Sessions 202 string
+ATTRIBUTE Lucent-Authen-Alias 203 string
+ATTRIBUTE Lucent-Token-Expiry 204 integer
+ATTRIBUTE Lucent-Menu-Selector 205 string
+ATTRIBUTE Lucent-Menu-Item 206 string
+ATTRIBUTE Lucent-PW-Warntime 207 integer
+ATTRIBUTE Lucent-PW-Lifetime 208 integer
+ATTRIBUTE Lucent-IP-Direct 209 ipaddr
+ATTRIBUTE Lucent-PPP-VJ-Slot-Comp 210 integer
+ATTRIBUTE Lucent-PPP-VJ-1172 211 integer
+ATTRIBUTE Lucent-PPP-Async-Map 212 integer
+ATTRIBUTE Lucent-Third-Prompt 213 string
+ATTRIBUTE Lucent-Send-Secret 214 string encrypt=3
+ATTRIBUTE Lucent-Receive-Secret 215 string encrypt=3
+ATTRIBUTE Lucent-IPX-Peer-Mode 216 integer
+ATTRIBUTE Lucent-IP-Pool-Definition 217 string
+ATTRIBUTE Lucent-Assign-IP-Pool 218 integer
+ATTRIBUTE Lucent-FR-Direct 219 integer
+ATTRIBUTE Lucent-FR-Direct-Profile 220 string
+ATTRIBUTE Lucent-FR-Direct-DLCI 221 integer
+ATTRIBUTE Lucent-Handle-IPX 222 integer
+ATTRIBUTE Lucent-Netware-timeout 223 integer
+ATTRIBUTE Lucent-IPX-Alias 224 integer
+ATTRIBUTE Lucent-Metric 225 integer
+ATTRIBUTE Lucent-PRI-Number-Type 226 integer
+ATTRIBUTE Lucent-Dial-Number 227 string
+ATTRIBUTE Lucent-Route-IP 228 integer
+ATTRIBUTE Lucent-Route-IPX 229 integer
+ATTRIBUTE Lucent-Bridge 230 integer
+ATTRIBUTE Lucent-Send-Auth 231 integer
+ATTRIBUTE Lucent-Send-Passwd 232 string
+ATTRIBUTE Lucent-Link-Compression 233 integer
+ATTRIBUTE Lucent-Target-Util 234 integer
+ATTRIBUTE Lucent-Maximum-Channels 235 integer
+ATTRIBUTE Lucent-Inc-Channel-Count 236 integer
+ATTRIBUTE Lucent-Dec-Channel-Count 237 integer
+ATTRIBUTE Lucent-Seconds-Of-History 238 integer
+ATTRIBUTE Lucent-History-Weigh-Type 239 integer
+ATTRIBUTE Lucent-Add-Seconds 240 integer
+ATTRIBUTE Lucent-Remove-Seconds 241 integer
+ATTRIBUTE Lucent-Data-Filter 242 abinary
+ATTRIBUTE Lucent-Call-Filter 243 abinary
+ATTRIBUTE Lucent-Idle-Limit 244 integer
+ATTRIBUTE Lucent-Preempt-Limit 245 integer
+ATTRIBUTE Lucent-Callback 246 integer
+ATTRIBUTE Lucent-Data-Svc 247 integer
+ATTRIBUTE Lucent-Force-56 248 integer
+ATTRIBUTE Lucent-Billing-Number 249 string
+ATTRIBUTE Lucent-Call-By-Call 250 integer
+ATTRIBUTE Lucent-Transit-Number 251 string
+ATTRIBUTE Lucent-Host-Info 252 string
+ATTRIBUTE Lucent-PPP-Address 253 ipaddr
+ATTRIBUTE Lucent-MPP-Idle-Percent 254 integer
+ATTRIBUTE Lucent-Xmit-Rate 255 integer
+ATTRIBUTE Lucent-Fr05-Traffic-Shaper 256 integer
+ATTRIBUTE Lucent-Fr05-Vpi 257 integer
+ATTRIBUTE Lucent-Fr05-Vci 258 integer
+ATTRIBUTE Lucent-Fr05-Enabled 259 integer
+ATTRIBUTE Lucent-Tunnel-Auth-Type 260 octets # tag?
+ATTRIBUTE Lucent-MOH-Timeout 261 integer
+ATTRIBUTE Lucent-ATM-Circuit-Name 262 string
+ATTRIBUTE Lucent-Priority-For-PPP 263 integer
+ATTRIBUTE Lucent-Max-RTP-Delay 264 integer
+ATTRIBUTE Lucent-RTP-Port-Range 265 string
+ATTRIBUTE Lucent-TOS-Copying 266 integer
+ATTRIBUTE Lucent-Packet-Classification 267 integer
+ATTRIBUTE Lucent-No-High-Prio-Pkt-Duratio 268 integer
+ATTRIBUTE Lucent-AT-Answer-String 269 string
+ATTRIBUTE Lucent-IP-OUTGOING-TOS 270 integer
+ATTRIBUTE Lucent-IP-OUTGOING-TOS-Precedence 271 integer
+ATTRIBUTE Lucent-IP-OUTGOING-DSCP 272 integer
+ATTRIBUTE Lucent-TermSrv-Login-Prompt 273 string
+ATTRIBUTE Lucent-Multicast-Service-Profile-Name 274 string
+ATTRIBUTE Lucent-Multicast-Max-Groups 275 integer
+ATTRIBUTE Lucent-Multicast-Service-Name 276 string
+ATTRIBUTE Lucent-Multicast-Service-Active 277 integer
+ATTRIBUTE Lucent-Multicast-Service-Snmp-Trap 278 integer
+ATTRIBUTE Lucent-Multicast-Service-Filter-Type 279 integer
+ATTRIBUTE Lucent-Multicast-Filter-Active 280 integer
+ATTRIBUTE Lucent-Multicast-Filter-Address 281 ipaddr
+ATTRIBUTE Lucent-Tunnel-TOS 282 integer
+ATTRIBUTE Lucent-Tunnel-TOS-Precedence 283 integer
+ATTRIBUTE Lucent-Tunnel-DSCP 284 integer
+ATTRIBUTE Lucent-Tunnel-TOS-Filter 285 string
+ATTRIBUTE Lucent-Tunnel-TOS-Copy 286 integer
+ATTRIBUTE Lucent-Http-Redirect-URL 287 string
+ATTRIBUTE Lucent-Http-Redirect-Port 288 integer
+ATTRIBUTE Lucent-L2TP-DCI-Disconnect-Code 289 integer
+ATTRIBUTE Lucent-L2TP-DCI-Protocol-Number 290 integer
+ATTRIBUTE Lucent-L2TP-DCI-Direction 291 integer
+ATTRIBUTE Lucent-L2TP-DCI-Message 292 string
+ATTRIBUTE Lucent-L2TP-Q931-Cause-Code 293 integer
+ATTRIBUTE Lucent-L2TP-Q931-Cause-Message 294 integer
+ATTRIBUTE Lucent-L2TP-Q931-Advisory-Message 295 string
+ATTRIBUTE Lucent-L2TP-RC-Result-Code 296 integer
+ATTRIBUTE Lucent-L2TP-RC-Error-Code 297 integer
+ATTRIBUTE Lucent-L2TP-RC-Error-Message 298 string
+ATTRIBUTE Lucent-L2TP-Disconnect-Scenario 299 integer
+ATTRIBUTE Lucent-L2TP-Peer-Disconnect-Cause 300 integer
+ATTRIBUTE Lucent-L2TP-Peer-Connect-Progress 301 integer
+ATTRIBUTE Lucent-QuickConnect-Attempted 302 integer
+ATTRIBUTE Lucent-Num-Moh-Sessions 303 integer
+ATTRIBUTE Lucent-Cumulative-Hold-Time 304 integer
+ATTRIBUTE Lucent-Modem-Modulation 305 integer
+ATTRIBUTE Lucent-User-Acct-Expiration 306 date
+ATTRIBUTE Lucent-User-Login-Level 307 integer
+ATTRIBUTE Lucent-First-Level-User 308 string
+ATTRIBUTE Lucent-IP-Source-If 309 string
+ATTRIBUTE Lucent-Reverse-Path-Check 310 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Chan-Uncorrect-Blks 10000 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Chan-Corrected-Blks 10001 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Chan-Xmit-Blks 10002 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Chan-Recd-Blks 10003 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-Inits 10004 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-ESs 10005 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-Lprs 10006 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-Lols 10007 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-Loss 10008 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Perf-Lofs 10009 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Attainable-Rate-Dn 10010 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Output-Pwr-Dn 10011 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Atn-Up 10012 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Snr-Mgn-Up 10013 integer
+#ATTRIBUTE Lucent-Dsl-Atuc-Perf-Stat-Fast-Retrains 10014 integer
+#ATTRIBUTE Lucent-Dsl-Atuc-Perf-Stat-Failed-Fast-Retrains 10015 integer
+
+# FIXME when we can deal with long attribute names.
+ATTRIBUTE Lucent-Dsl-Atuc-PS-Fast-Retrains 10014 integer
+ATTRIBUTE Lucent-Dsl-Atuc-PS-Failed-Fast-Retrains 10015 integer
+
+ATTRIBUTE Lucent-Dsl-Code-Violations 10016 integer
+ATTRIBUTE Lucent-Line-Type 10017 integer
+ATTRIBUTE Lucent-Dsl-Curr-Up-Rate 10018 integer
+ATTRIBUTE Lucent-Dsl-Curr-Dn-Rate 10019 integer
+ATTRIBUTE Lucent-Dsl-Physical-Slot 10020 integer
+ATTRIBUTE Lucent-Dsl-Physical-Line 10021 integer
+ATTRIBUTE Lucent-Dsl-If-Index 10022 integer
+ATTRIBUTE Lucent-Dsl-Oper-Status 10023 integer
+ATTRIBUTE Lucent-Dsl-Related-If-Index 10024 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Attainable-Rate-Up 10025 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Output-Pwr-Up 10026 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Atn-Dn 10027 integer
+ATTRIBUTE Lucent-Dsl-Atuc-Curr-Snr-Mgn-D 10028 integer
+ATTRIBUTE Lucent-Dsl-Related-Slot 10029 integer
+ATTRIBUTE Lucent-Dsl-Related-Port 10030 integer
+ATTRIBUTE Lucent-Dsl-Sparing-Role 10031 integer
+ATTRIBUTE Lucent-Absolute-Time 10032 integer
+ATTRIBUTE Lucent-Configured-Rate-Up-Min 10033 integer
+ATTRIBUTE Lucent-Configured-Rate-Up-Max 10034 integer
+ATTRIBUTE Lucent-Configured-Rate-Dn-Min 10035 integer
+ATTRIBUTE Lucent-Configured-Rate-Dn-Max 10036 integer
+ATTRIBUTE Lucent-Dsl-Physical-Channel 10037 integer
+ATTRIBUTE Lucent-Sonet-Section-ESs 10100 integer
+ATTRIBUTE Lucent-Sonet-Section-SESs 10101 integer
+ATTRIBUTE Lucent-Sonet-Section-SEFSs 10102 integer
+ATTRIBUTE Lucent-Sonet-Section-CVs 10103 integer
+ATTRIBUTE Lucent-Sonet-Line-ESs-Near 10104 integer
+ATTRIBUTE Lucent-Sonet-Line-SESs-Near 10105 integer
+ATTRIBUTE Lucent-Sonet-Line-CVs-Near 10106 integer
+ATTRIBUTE Lucent-Sonet-Line-USs-Near 10107 integer
+ATTRIBUTE Lucent-Sonet-Line-ESs-Far 10108 integer
+ATTRIBUTE Lucent-Sonet-Line-SESs-Far 10109 integer
+ATTRIBUTE Lucent-Sonet-Line-CVs-Far 10110 integer
+ATTRIBUTE Lucent-Sonet-Line-USs-Far 10111 integer
+ATTRIBUTE Lucent-Sonet-Path-ESs-Near 10112 integer
+ATTRIBUTE Lucent-Sonet-Path-SESs-Near 10113 integer
+ATTRIBUTE Lucent-Sonet-Path-CVs-Near 10114 integer
+ATTRIBUTE Lucent-Sonet-Path-USs-Near 10115 integer
+ATTRIBUTE Lucent-Sonet-Path-ESs-Far 10116 integer
+ATTRIBUTE Lucent-Sonet-Path-SESs-Far 10117 integer
+ATTRIBUTE Lucent-Sonet-Path-CVs-Far 10118 integer
+ATTRIBUTE Lucent-Sonet-Path-USs-Far 10119 integer
+ATTRIBUTE Lucent-Ds3-F-Bit-Err 10200 integer
+ATTRIBUTE Lucent-Ds3-P-Bit-Err 10201 integer
+ATTRIBUTE Lucent-Ds3-CCVs 10202 integer
+ATTRIBUTE Lucent-Ds3-PESs 10203 integer
+ATTRIBUTE Lucent-Ds3-PSESs 10204 integer
+ATTRIBUTE Lucent-Ds3-SEFs 10205 integer
+ATTRIBUTE Lucent-Ds3-UASs 10206 integer
+ATTRIBUTE Lucent-Ds3-LCVs 10207 integer
+ATTRIBUTE Lucent-Ds3-PCVs 10208 integer
+ATTRIBUTE Lucent-Ds3-LESs 10209 integer
+ATTRIBUTE Lucent-Ds3-CESs 10210 integer
+ATTRIBUTE Lucent-Ds3-CSESs 10211 integer
+ATTRIBUTE Lucent-Rtp-Local-Number-Of-Samples 10300 integer
+ATTRIBUTE Lucent-Rtp-Remote-Number-Of-Samples 10301 integer
+ATTRIBUTE Lucent-Rtp-Local-Jitter-Minimum 10302 integer
+ATTRIBUTE Lucent-Rtp-Local-Jitter-Maximum 10303 integer
+ATTRIBUTE Lucent-Rtp-Local-Jitter-Mean 10304 integer
+ATTRIBUTE Lucent-Rtp-Local-Jitter-Variance 10305 integer
+ATTRIBUTE Lucent-Rtp-Local-Delay-Minimum 10306 integer
+ATTRIBUTE Lucent-Rtp-Local-Delay-Maximum 10307 integer
+ATTRIBUTE Lucent-Rtp-Local-Delay-Mean 10308 integer
+ATTRIBUTE Lucent-Rtp-Local-Delay-Variance 10309 integer
+ATTRIBUTE Lucent-Rtp-Local-Packets-Sent 10310 integer
+ATTRIBUTE Lucent-Rtp-Local-Packets-Lost 10311 integer
+ATTRIBUTE Lucent-Rtp-Local-Packets-Late 10312 integer
+ATTRIBUTE Lucent-Rtp-Local-Bytes-Sent 10313 integer
+ATTRIBUTE Lucent-Rtp-Local-Silence-Percent 10314 integer
+ATTRIBUTE Lucent-Rtp-Remote-Jitter-Minimum 10315 integer
+ATTRIBUTE Lucent-Rtp-Remote-Jitter-Maximum 10316 integer
+ATTRIBUTE Lucent-Rtp-Remote-Jitter-Mean 10317 integer
+ATTRIBUTE Lucent-Rtp-Remote-Jitter-Variance 10318 integer
+ATTRIBUTE Lucent-Rtp-Remote-Delay-Minimum 10319 integer
+ATTRIBUTE Lucent-Rtp-Remote-Delay-Maximum 10320 integer
+ATTRIBUTE Lucent-Rtp-Remote-Delay-Mean 10321 integer
+ATTRIBUTE Lucent-Rtp-Remote-Delay-Variance 10322 integer
+ATTRIBUTE Lucent-Rtp-Remote-Packets-Sent 10323 integer
+ATTRIBUTE Lucent-Rtp-Remote-Packets-Lost 10324 integer
+ATTRIBUTE Lucent-Rtp-Remote-Packets-Late 10325 integer
+ATTRIBUTE Lucent-Rtp-Remote-Bytes-Sent 10326 integer
+ATTRIBUTE Lucent-Rtp-Remote-Silence-Percent 10327 integer
+ATTRIBUTE Lucent-Tunnel-Auth-Type2 19999 integer
+ATTRIBUTE Lucent-Multi-Packet-Separator 20000 integer
+ATTRIBUTE Lucent-Min-Xmit-Rate 20100 integer
+ATTRIBUTE Lucent-Max-Xmit-Rate 20101 integer
+ATTRIBUTE Lucent-Min-Recv-Rate 20102 integer
+ATTRIBUTE Lucent-Max-Recv-Rate 20103 integer
+ATTRIBUTE Lucent-Error-Correction-Protocol 20104 integer
+ATTRIBUTE Lucent-Compression-Protocol 20105 integer
+ATTRIBUTE Lucent-Modulation 20106 integer
+ATTRIBUTE Lucent-Xmit-Symbol-Rate 20107 integer
+ATTRIBUTE Lucent-Recv-Symbol-Rate 20108 integer
+ATTRIBUTE Lucent-Current-Xmit-Level 20109 integer
+ATTRIBUTE Lucent-Current-Recv-Level 20110 integer
+ATTRIBUTE Lucent-Current-Line-Quality 20111 integer
+ATTRIBUTE Lucent-Current-SNR 20112 integer
+ATTRIBUTE Lucent-Min-SNR 20113 integer
+ATTRIBUTE Lucent-Max-SNR 20114 integer
+ATTRIBUTE Lucent-Local-Retrain-Requested 20115 integer
+ATTRIBUTE Lucent-Remote-Retrain-Requested 20116 integer
+ATTRIBUTE Lucent-Connection-Time 20117 integer
+ATTRIBUTE Lucent-Modem-Disconnect-Reason 20118 integer
+ATTRIBUTE Lucent-Retrain-Reason 20119 integer
+
+END-VENDOR Lucent
+# -*- text -*-
#
# For Merit.
#
# $Id$
#
-VENDOR Merit 61
-
-ATTRIBUTE Merit-Proxy-Action 211 string Merit
-ATTRIBUTE Merit-User-Id 222 string Merit
-ATTRIBUTE Merit-User-Realm 223 string Merit
+VENDOR Merit 61
+BEGIN-VENDOR Merit
+ATTRIBUTE Merit-Proxy-Action 211 string
+ATTRIBUTE Merit-User-Id 222 string
+ATTRIBUTE Merit-User-Realm 223 string
+END-VENDOR Merit
+# -*- text -*-
#
# Microsoft's VSA's, from RFC 2548
#
# $Id$
#
-VENDOR Microsoft 311
+VENDOR Microsoft 311
-BEGIN-VENDOR Microsoft
-ATTRIBUTE MS-CHAP-Response 1 octets
-ATTRIBUTE MS-CHAP-Error 2 string
-ATTRIBUTE MS-CHAP-CPW-1 3 octets
-ATTRIBUTE MS-CHAP-CPW-2 4 octets
-ATTRIBUTE MS-CHAP-LM-Enc-PW 5 octets
-ATTRIBUTE MS-CHAP-NT-Enc-PW 6 octets
-ATTRIBUTE MS-MPPE-Encryption-Policy 7 octets
+BEGIN-VENDOR Microsoft
+ATTRIBUTE MS-CHAP-Response 1 octets
+ATTRIBUTE MS-CHAP-Error 2 string
+ATTRIBUTE MS-CHAP-CPW-1 3 octets
+ATTRIBUTE MS-CHAP-CPW-2 4 octets
+ATTRIBUTE MS-CHAP-LM-Enc-PW 5 octets
+ATTRIBUTE MS-CHAP-NT-Enc-PW 6 octets
+ATTRIBUTE MS-MPPE-Encryption-Policy 7 octets
# This is referred to as both singular and plural in the RFC.
# Plural seems to make more sense.
-ATTRIBUTE MS-MPPE-Encryption-Type 8 octets
-ATTRIBUTE MS-MPPE-Encryption-Types 8 octets
-ATTRIBUTE MS-RAS-Vendor 9 integer # content is Vendor-ID
-ATTRIBUTE MS-CHAP-Domain 10 string
-ATTRIBUTE MS-CHAP-Challenge 11 octets
-ATTRIBUTE MS-CHAP-MPPE-Keys 12 octets encrypt=1
-ATTRIBUTE MS-BAP-Usage 13 integer
-ATTRIBUTE MS-Link-Utilization-Threshold 14 integer # values are 1-100
-ATTRIBUTE MS-Link-Drop-Time-Limit 15 integer
-ATTRIBUTE MS-MPPE-Send-Key 16 octets encrypt=2
-ATTRIBUTE MS-MPPE-Recv-Key 17 octets encrypt=2
-ATTRIBUTE MS-RAS-Version 18 string
-ATTRIBUTE MS-Old-ARAP-Password 19 octets
-ATTRIBUTE MS-New-ARAP-Password 20 octets
-ATTRIBUTE MS-ARAP-PW-Change-Reason 21 integer
-
-ATTRIBUTE MS-Filter 22 octets
-ATTRIBUTE MS-Acct-Auth-Type 23 integer
-ATTRIBUTE MS-Acct-EAP-Type 24 integer
-
-ATTRIBUTE MS-CHAP2-Response 25 octets
-ATTRIBUTE MS-CHAP2-Success 26 octets
-ATTRIBUTE MS-CHAP2-CPW 27 octets
-
-ATTRIBUTE MS-Primary-DNS-Server 28 ipaddr
-ATTRIBUTE MS-Secondary-DNS-Server 29 ipaddr
-ATTRIBUTE MS-Primary-NBNS-Server 30 ipaddr
-ATTRIBUTE MS-Secondary-NBNS-Server 31 ipaddr
+ATTRIBUTE MS-MPPE-Encryption-Type 8 octets
+ATTRIBUTE MS-MPPE-Encryption-Types 8 octets
+ATTRIBUTE MS-RAS-Vendor 9 integer # content is Vendor-ID
+ATTRIBUTE MS-CHAP-Domain 10 string
+ATTRIBUTE MS-CHAP-Challenge 11 octets
+ATTRIBUTE MS-CHAP-MPPE-Keys 12 octets encrypt=1
+ATTRIBUTE MS-BAP-Usage 13 integer
+ATTRIBUTE MS-Link-Utilization-Threshold 14 integer # values are 1-100
+ATTRIBUTE MS-Link-Drop-Time-Limit 15 integer
+ATTRIBUTE MS-MPPE-Send-Key 16 octets encrypt=2
+ATTRIBUTE MS-MPPE-Recv-Key 17 octets encrypt=2
+ATTRIBUTE MS-RAS-Version 18 string
+ATTRIBUTE MS-Old-ARAP-Password 19 octets
+ATTRIBUTE MS-New-ARAP-Password 20 octets
+ATTRIBUTE MS-ARAP-PW-Change-Reason 21 integer
+
+ATTRIBUTE MS-Filter 22 octets
+ATTRIBUTE MS-Acct-Auth-Type 23 integer
+ATTRIBUTE MS-Acct-EAP-Type 24 integer
+
+ATTRIBUTE MS-CHAP2-Response 25 octets
+ATTRIBUTE MS-CHAP2-Success 26 octets
+ATTRIBUTE MS-CHAP2-CPW 27 octets
+
+ATTRIBUTE MS-Primary-DNS-Server 28 ipaddr
+ATTRIBUTE MS-Secondary-DNS-Server 29 ipaddr
+ATTRIBUTE MS-Primary-NBNS-Server 30 ipaddr
+ATTRIBUTE MS-Secondary-NBNS-Server 31 ipaddr
#ATTRIBUTE MS-ARAP-Challenge 33 octets
-
#
# Integer Translations
#
# MS-BAP-Usage Values
-VALUE MS-BAP-Usage Not-Allowed 0
-VALUE MS-BAP-Usage Allowed 1
-VALUE MS-BAP-Usage Required 2
+VALUE MS-BAP-Usage Not-Allowed 0
+VALUE MS-BAP-Usage Allowed 1
+VALUE MS-BAP-Usage Required 2
# MS-ARAP-Password-Change-Reason Values
-VALUE MS-ARAP-PW-Change-Reason Just-Change-Password 1
-VALUE MS-ARAP-PW-Change-Reason Expired-Password 2
-VALUE MS-ARAP-PW-Change-Reason Admin-Requires-Password-Change 3
-VALUE MS-ARAP-PW-Change-Reason Password-Too-Short 4
+VALUE MS-ARAP-PW-Change-Reason Just-Change-Password 1
+VALUE MS-ARAP-PW-Change-Reason Expired-Password 2
+VALUE MS-ARAP-PW-Change-Reason Admin-Requires-Password-Change 3
+VALUE MS-ARAP-PW-Change-Reason Password-Too-Short 4
# MS-Acct-Auth-Type Values
-VALUE MS-Acct-Auth-Type PAP 1
-VALUE MS-Acct-Auth-Type CHAP 2
-VALUE MS-Acct-Auth-Type MS-CHAP-1 3
-VALUE MS-Acct-Auth-Type MS-CHAP-2 4
-VALUE MS-Acct-Auth-Type EAP 5
+VALUE MS-Acct-Auth-Type PAP 1
+VALUE MS-Acct-Auth-Type CHAP 2
+VALUE MS-Acct-Auth-Type MS-CHAP-1 3
+VALUE MS-Acct-Auth-Type MS-CHAP-2 4
+VALUE MS-Acct-Auth-Type EAP 5
# MS-Acct-EAP-Type Values
-VALUE MS-Acct-EAP-Type MD5 4
-VALUE MS-Acct-EAP-Type OTP 5
-VALUE MS-Acct-EAP-Type Generic-Token-Card 6
-VALUE MS-Acct-EAP-Type TLS 13
+VALUE MS-Acct-EAP-Type MD5 4
+VALUE MS-Acct-EAP-Type OTP 5
+VALUE MS-Acct-EAP-Type Generic-Token-Card 6
+VALUE MS-Acct-EAP-Type TLS 13
END-VENDOR Microsoft
+# -*- text -*-
# http://www.mikrotik.com
#
# http://www.mikrotik.com/Documentation/manual_2.7/Basic/AAA.html#ht37996460
#
# $Id$
#
-VENDOR Mikrotik 14988
+VENDOR Mikrotik 14988
-ATTRIBUTE Mikrotik-Recv-Limit 1 integer Mikrotik
-ATTRIBUTE Mikrotik-Xmit-Limit 2 integer Mikrotik
+BEGIN-VENDOR Mikrotik
+
+ATTRIBUTE Mikrotik-Recv-Limit 1 integer
+ATTRIBUTE Mikrotik-Xmit-Limit 2 integer
# this attribute is unused
-ATTRIBUTE Mikrotik-Group 3 string Mikrotik
+ATTRIBUTE Mikrotik-Group 3 string
+
+ATTRIBUTE Mikrotik-Wireless-Forward 4 integer
+ATTRIBUTE Mikrotik-Wireless-Skip-Dot1x 5 integer
+ATTRIBUTE Mikrotik-Wireless-Enc-Algo 6 integer
+ATTRIBUTE WMikrotik-ireless-Enc-Key 7 string
+ATTRIBUTE Mikrotik-Rate-Limit 8 string
+ATTRIBUTE Mikrotik-Realm 9 string
+
+# MikroTik Values
+
+VALUE Mikrotik-Wireless-Enc-Algo No-encryption 0
+VALUE Mikrotik-Wireless-Enc-Algo 40-bit-WEP 1
+VALUE Mikrotik-Wireless-Enc-Algo 104-bit-WEP 2
+
+END-VENDOR Mikrotik
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Motorola Canopy attributes.
+#
+# NOT included in the main dictionaries because of conflicts
+# with Ascend attributes.
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Motorola 161
+
+ATTRIBUTE Motorola-Canopy-Shared-Secret 224 string
+ATTRIBUTE Motorola-Canopy-SULDR 225 string
+ATTRIBUTE Motorola-Canopy-SDLDR 226 string
+ATTRIBUTE Motorola-Canopy-ULBA 227 string
+ATTRIBUTE Motorola-Canopy-DLBA 228 string
+ATTRIBUTE Motorola-Canopy-Enable 229 string
+ATTRIBUTE Motorola-Canopy-LPSULDR 230 string
+ATTRIBUTE Motorola-Canopy-LPSDLDR 231 string
+ATTRIBUTE Motorola-Canopy-HPCENABLE 232 string
+ATTRIBUTE Motorola-Canopy-HPSULDR 233 string
+ATTRIBUTE Motorola-Canopy-HPSDLDR 234 string
+ATTRIBUTE Motorola-Canopy-HIGHERBW 235 string
+ATTRIBUTE Motorola-Canopy-CIRENABLE 236 string
+# -*- text -*-
#
# dictionary.navini
#
# Version: $Id$
#
-VENDOR Navini 6504
+VENDOR Navini 6504
#
# Standard attribute
#
-ATTRIBUTE Navini-AVPair 1 string Navini
+BEGIN-VENDOR Navini
+
+ATTRIBUTE Navini-AVPair 1 string
+
+END-VENDOR Navini
+# -*- text -*-
#
# From:
# http://www.netscreen.com/support/downloads/4.0_configuring_screenOS_for_NTdomain_v11.pdf
#
-VENDOR Netscreen 3224
+VENDOR Netscreen 3224
-ATTRIBUTE NS-Admin-Privilege 1 integer Netscreen
-ATTRIBUTE NS-VSYS-Name 2 string Netscreen
-ATTRIBUTE NS-User-Group 3 string Netscreen
-ATTRIBUTE NS-Primary-DNS 4 ipaddr Netscreen
-ATTRIBUTE NS-Secondary-DNS 5 ipaddr Netscreen
-ATTRIBUTE NS-Primary-WINS 6 ipaddr Netscreen
-ATTRIBUTE NS-Secondary-WINS 7 ipaddr Netscreen
+BEGIN-VENDOR Netscreen
+
+ATTRIBUTE NS-Admin-Privilege 1 integer
+ATTRIBUTE NS-VSYS-Name 2 string
+ATTRIBUTE NS-User-Group 3 string
+ATTRIBUTE NS-Primary-DNS 4 ipaddr
+ATTRIBUTE NS-Secondary-DNS 5 ipaddr
+ATTRIBUTE NS-Primary-WINS 6 ipaddr
+ATTRIBUTE NS-Secondary-WINS 7 ipaddr
#
# Values VSYS-Admin and Read-Only-VSYS-Admin require a NS-VSYS-Name
# attribute in the response packet.
#
-VALUE NS-Admin-Privilege Root-Admin 1
-VALUE NS-Admin-Privilege All-VSYS-Root-Admin 2
-VALUE NS-Admin-Privilege VSYS-Admin 3
-VALUE NS-Admin-Privilege Read-Only-Admin 4
-VALUE NS-Admin-Privilege Read-Only-VSYS-Admin 5
+VALUE NS-Admin-Privilege Root-Admin 1
+VALUE NS-Admin-Privilege All-VSYS-Root-Admin 2
+VALUE NS-Admin-Privilege VSYS-Admin 3
+VALUE NS-Admin-Privilege Read-Only-Admin 4
+VALUE NS-Admin-Privilege Read-Only-VSYS-Admin 5
+
+END-VENDOR Netscreen
+# -*- text -*-
#
# Nokia dictionary
# $Id$
#
+VENDOR Nokia 94
+
+BEGIN-VENDOR Nokia
+
+ATTRIBUTE Nokia-User-Profile 2 string
+ATTRIBUTE Nokia-Service-Name 3 octets # magic format
+ATTRIBUTE Nokia-Service-Id 4 octets # magic format
+ATTRIBUTE Nokia-Service-Username 5 octets # magic format
+ATTRIBUTE Nokia-Service-Password 6 octets # magic format
+ATTRIBUTE Nokia-Service-Primary-Indicator 7 octets
+ATTRIBUTE Nokia-Service-Charging-Type 8 octets # magic format
+ATTRIBUTE Nokia-Service-Encrypted-Password 9 octets # magic format
+ATTRIBUTE Nokia-Session-Access-Method 10 octets
+ATTRIBUTE Nokia-Session-Charging-Type 11 octets
+
+END-VENDOR Nokia
+
# Enable by putting the line "$INCLUDE dictionary.nokia" into
# the main dictionary file. Don't forget to comment out the
# $INCLUDE dictionary.ascend, because these over-lap with the
#
#
-# The format of this attribute is binary coded decimal (BCD)
+# The format of these attributes is binary coded decimal (BCD)
# with the last four bits all set to 1 if there are an odd
# number of digits,
#
#
# This is an incredibly stupid way of encoding the data.
#
-ATTRIBUTE Nokia-IMSI 224 octets
-ATTRIBUTE Nokia-Charging-Id 225 integer
-ATTRIBUTE Nokia-Prepaid-Ind 226 integer
-ATTRIBUTE Nokia-GGSN-IP-Address 227 ipaddr
-ATTRIBUTE Nokia-SGSN-IP-Address 228 ipaddr
+ATTRIBUTE Nokia-Primary-DNS-Server 135 ipaddr
+ATTRIBUTE Nokia-Secondary-DNS-Server 135 ipaddr
+ATTRIBUTE Nokia-IMSI 224 octets
+ATTRIBUTE Nokia-Charging-Id 225 integer
+ATTRIBUTE Nokia-Prepaid-Ind 226 integer
+ATTRIBUTE Nokia-GGSN-IP-Address 227 ipaddr
+ATTRIBUTE Nokia-SGSN-IP-Address 228 ipaddr
+
+# -*- text -*-
#
# Version: $Id$
#
-VENDOR Nomadix 3309
+VENDOR Nomadix 3309
#
-ATTRIBUTE Nomadix-Bw-Up 1 integer Nomadix
-ATTRIBUTE Nomadix-Bw-Down 2 integer Nomadix
-ATTRIBUTE Nomadix-URL-Redirection 3 string Nomadix
-ATTRIBUTE Nomadix-IP-Upsell 4 integer Nomadix
-ATTRIBUTE Nomadix-Expiration 5 string Nomadix
-ATTRIBUTE Nomadix-Subnet 6 string Nomadix
-ATTRIBUTE Nomadix-MaxBytesUp 7 integer Nomadix
-ATTRIBUTE Nomadix-MaxBytesDown 8 integer Nomadix
-ATTRIBUTE Nomadix-EndofSession 9 integer Nomadix
-ATTRIBUTE Nomadix-Logoff-URL 10 string Nomadix
-ATTRIBUTE Nomadix-Net-VLAN 11 integer Nomadix
-ATTRIBUTE Nomadix-Config-URL 12 string Nomadix
-ATTRIBUTE Nomadix-Goodbye-URL 13 string Nomadix
+BEGIN-VENDOR Nomadix
-VALUE Nomadix-Ip-Upsell PrivatePool 0
-VALUE Nomadix-Ip-Upsell PublicPool 1
+ATTRIBUTE Nomadix-Bw-Up 1 integer
+ATTRIBUTE Nomadix-Bw-Down 2 integer
+ATTRIBUTE Nomadix-URL-Redirection 3 string
+ATTRIBUTE Nomadix-IP-Upsell 4 integer
+ATTRIBUTE Nomadix-Expiration 5 string
+ATTRIBUTE Nomadix-Subnet 6 string
+ATTRIBUTE Nomadix-MaxBytesUp 7 integer
+ATTRIBUTE Nomadix-MaxBytesDown 8 integer
+ATTRIBUTE Nomadix-EndofSession 9 integer
+ATTRIBUTE Nomadix-Logoff-URL 10 string
+ATTRIBUTE Nomadix-Net-VLAN 11 integer
+ATTRIBUTE Nomadix-Config-URL 12 string
+ATTRIBUTE Nomadix-Goodbye-URL 13 string
+
+VALUE Nomadix-Ip-Upsell PrivatePool 0
+VALUE Nomadix-Ip-Upsell PublicPool 1
+
+END-VENDOR Nomadix
--- /dev/null
+# -*- text -*-
+VENDOR NTUA 969
+
+BEGIN-VENDOR NTUA
+
+#
+# Authentication Attributes
+#
+ATTRIBUTE UserLogon-Uid 10 integer
+ATTRIBUTE UserLogon-Gid 11 integer
+ATTRIBUTE UserLogon-HomeDir 12 string
+ATTRIBUTE UserLogon-Type 13 integer
+ATTRIBUTE UserLogon-QuotaBytes 14 integer
+ATTRIBUTE UserLogon-QuotaFiles 15 integer
+ATTRIBUTE UserLogon-Shell 16 string
+ATTRIBUTE UserLogon-Restriction 17 integer
+ATTRIBUTE UserLogon-GroupNames 18 string
+ATTRIBUTE UserLogon-DriveNames 19 string
+ATTRIBUTE UserLogon-UserDescription 20 string
+ATTRIBUTE UserLogon-UserFullName 21 string
+ATTRIBUTE UserLogon-UserDomain 22 string
+ATTRIBUTE UserLogon-LogonTask 23 string
+ATTRIBUTE UserLogon-LogoffTask 24 string
+ATTRIBUTE UserLogon-Expiration 25 string
+ATTRIBUTE UserLogon-UserProfile 26 string
+#
+# Accounting Attributes
+#
+ATTRIBUTE UserLogon-Acct-TerminateCause 50 string
+
+VALUE UserLogon-Type FTP 1
+VALUE UserLogon-Type WEB 2
+VALUE UserLogon-Type POP 3
+VALUE UserLogon-Type IMAP 4
+VALUE UserLogon-Type Windows-Logon 5
+VALUE UserLogon-Type Unix-Logon 6
+VALUE UserLogon-Type SMTP-Auth 7
+VALUE UserLogon-Type Other 200
+
+VALUE UserLogon-Restriction Anonymous-User 1
+VALUE UserLogon-Restriction Admin-User 2
+
+END-VENDOR NTUA
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Packeteer VSAs, who followed the Cisco way of putting everything
+# into one text string.
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Packeteer 2334
+
+#
+# Standard attribute
+#
+BEGIN-VENDOR Packeteer
+
+ATTRIBUTE Packeteer-AVPair 1 string
+
+END-VENDOR Packeteer
+# -*- text -*-
#
# Found on the net.
#
# $Id$
#
-VENDOR Propel 14895
+VENDOR Propel 14895
BEGIN-VENDOR Propel
ATTRIBUTE Propel-Accelerate 1 integer
ATTRIBUTE Propel-Client-IP-Address 3 ipaddr
ATTRIBUTE Propel-Client-NAS-IP-Address 4 ipaddr
ATTRIBUTE Propel-Client-Source-ID 5 integer
+ATTRIBUTE Propel-Content-Filter-ID 6 integer
END-VENDOR Propel
+# -*- text -*-
#
# dictionary.quintum
#
# Jeremy McNamara <jj@indie.org>
#
# Version: $Id$
-#
+#
-VENDOR Quintum 6618
+VENDOR Quintum 6618
#
# Standard attribute
#
-ATTRIBUTE Quintum-AVPair 1 string Quintum
-ATTRIBUTE Quintum-NAS-Port 2 string Quintum
+BEGIN-VENDOR Quintum
+
+ATTRIBUTE Quintum-AVPair 1 string
+ATTRIBUTE Quintum-NAS-Port 2 string
#
# Voice over IP attributes.
#
-ATTRIBUTE Quintum-h323-remote-address 23 string Quintum
-ATTRIBUTE Quintum-h323-conf-id 24 string Quintum
-ATTRIBUTE Quintum-h323-setup-time 25 string Quintum
-ATTRIBUTE Quintum-h323-call-origin 26 string Quintum
-ATTRIBUTE Quintum-h323-call-type 27 string Quintum
-ATTRIBUTE Quintum-h323-connect-time 28 string Quintum
-ATTRIBUTE Quintum-h323-disconnect-time 29 string Quintum
-ATTRIBUTE Quintum-h323-disconnect-cause 30 string Quintum
-ATTRIBUTE Quintum-h323-voice-quality 31 string Quintum
-ATTRIBUTE Quintum-h323-gw-id 33 string Quintum
-ATTRIBUTE Quintum-h323-incoming-conf-id 35 string Quintum
+ATTRIBUTE Quintum-h323-remote-address 23 string
+ATTRIBUTE Quintum-h323-conf-id 24 string
+ATTRIBUTE Quintum-h323-setup-time 25 string
+ATTRIBUTE Quintum-h323-call-origin 26 string
+ATTRIBUTE Quintum-h323-call-type 27 string
+ATTRIBUTE Quintum-h323-connect-time 28 string
+ATTRIBUTE Quintum-h323-disconnect-time 29 string
+ATTRIBUTE Quintum-h323-disconnect-cause 30 string
+ATTRIBUTE Quintum-h323-voice-quality 31 string
+ATTRIBUTE Quintum-h323-gw-id 33 string
+ATTRIBUTE Quintum-h323-incoming-conf-id 35 string
-ATTRIBUTE Quintum-h323-credit-amount 101 string Quintum
-ATTRIBUTE Quintum-h323-credit-time 102 string Quintum
-ATTRIBUTE Quintum-h323-return-code 103 string Quintum
-ATTRIBUTE Quintum-h323-prompt-id 104 string Quintum
-ATTRIBUTE Quintum-h323-time-and-day 105 string Quintum
-ATTRIBUTE Quintum-h323-redirect-number 106 string Quintum
-ATTRIBUTE Quintum-h323-preferred-lang 107 string Quintum
-ATTRIBUTE Quintum-h323-redirect-ip-address 108 string Quintum
-ATTRIBUTE Quintum-h323-billing-model 109 string Quintum
-ATTRIBUTE Quintum-h323-currency-type 110 string Quintum
+ATTRIBUTE Quintum-h323-credit-amount 101 string
+ATTRIBUTE Quintum-h323-credit-time 102 string
+ATTRIBUTE Quintum-h323-return-code 103 string
+ATTRIBUTE Quintum-h323-prompt-id 104 string
+ATTRIBUTE Quintum-h323-time-and-day 105 string
+ATTRIBUTE Quintum-h323-redirect-number 106 string
+ATTRIBUTE Quintum-h323-preferred-lang 107 string
+ATTRIBUTE Quintum-h323-redirect-ip-address 108 string
+ATTRIBUTE Quintum-h323-billing-model 109 string
+ATTRIBUTE Quintum-h323-currency-type 110 string
+END-VENDOR Quintum
+# -*- text -*-
#
# Redback dictionary.
#
# $Id$
#
-VENDOR Redback 2352
+VENDOR Redback 2352
#
# Redback Vendor Specific Extensions
#
-# The first set here uses '_' as the separator, as Redback has changed
+# The first set here uses '_' as the separator, as Redback has changed
# their documentation to use '-' vs. '_'. The older '_' style entries
# are listed first so that they will still be accepted,
# yet not preferred.
# The names use underscores (_) instead of dashes (-), because
# that's what Redback used in their older documentation and examples.
#
-ATTRIBUTE Client_DNS_Pri 1 ipaddr Redback
-ATTRIBUTE Client_DNS_Sec 2 ipaddr Redback
-ATTRIBUTE DHCP_Max_Leases 3 integer Redback
-ATTRIBUTE Context_Name 4 string Redback
-ATTRIBUTE Bridge_Group 5 string Redback
-ATTRIBUTE BG_Aging_Time 6 string Redback
-ATTRIBUTE BG_Path_Cost 7 string Redback
-ATTRIBUTE BG_Span_Dis 8 string Redback
-ATTRIBUTE BG_Trans_BPDU 9 string Redback
-ATTRIBUTE Rate_Limit_Rate 10 integer Redback
-ATTRIBUTE Rate_Limit_Burst 11 integer Redback
-ATTRIBUTE Police_Rate 12 integer Redback
-ATTRIBUTE Police_Burst 13 integer Redback
-ATTRIBUTE Source_Validation 14 integer Redback
-ATTRIBUTE Tunnel_Domain 15 integer Redback
-ATTRIBUTE Tunnel_Local_Name 16 string Redback
-ATTRIBUTE Tunnel_Remote_Name 17 string Redback
-ATTRIBUTE Tunnel_Function 18 integer Redback
-ATTRIBUTE Tunnel_Max_Sessions 21 integer Redback
-ATTRIBUTE Tunnel_Max_Tunnels 22 integer Redback
-ATTRIBUTE Tunnel_Session_Auth 23 integer Redback
-ATTRIBUTE Tunnel_Window 24 integer Redback
-ATTRIBUTE Tunnel_Retransmit 25 integer Redback
-ATTRIBUTE Tunnel_Cmd_Timeout 26 integer Redback
-ATTRIBUTE PPPOE_URL 27 string Redback
-ATTRIBUTE PPPOE_MOTM 28 string Redback
-ATTRIBUTE Tunnel_Group 29 integer Redback
-ATTRIBUTE Tunnel_Context 30 string Redback
-ATTRIBUTE Tunnel_Algorithm 31 integer Redback
-ATTRIBUTE Tunnel_Deadtime 32 integer Redback
-ATTRIBUTE Mcast_Send 33 integer Redback
-ATTRIBUTE Mcast_Receive 34 integer Redback
-ATTRIBUTE Mcast_MaxGroups 35 integer Redback
-ATTRIBUTE Ip_Address_Pool_Name 36 string Redback
-ATTRIBUTE Tunnel_DNIS 37 integer Redback
-ATTRIBUTE Medium_Type 38 integer Redback
-ATTRIBUTE PVC_Encapsulation_Type 39 integer Redback
-ATTRIBUTE PVC_Profile_Name 40 string Redback
-ATTRIBUTE PVC_Circuit_Padding 41 integer Redback
-ATTRIBUTE Bind_Type 42 integer Redback
-ATTRIBUTE Bind_Auth_Protocol 43 integer Redback
-ATTRIBUTE Bind_Auth_Max_Sessions 44 integer Redback
-ATTRIBUTE Bind_Bypass_Bypass 45 string Redback
-ATTRIBUTE Bind_Auth_Context 46 string Redback
-ATTRIBUTE Bind_Auth_Service_Grp 47 string Redback
-ATTRIBUTE Bind_Bypass_Context 48 string Redback
-ATTRIBUTE Bind_Int_Context 49 string Redback
-ATTRIBUTE Bind_Tun_Context 50 string Redback
-ATTRIBUTE Bind_Ses_Context 51 string Redback
-ATTRIBUTE Bind_Dot1q_Slot 52 integer Redback
-ATTRIBUTE Bind_Dot1q_Port 53 integer Redback
-ATTRIBUTE Bind_Dot1q_Vlan_Tag_Id 54 integer Redback
-ATTRIBUTE Bind_Int_Interface_Name 55 string Redback
-ATTRIBUTE Bind_L2TP_Tunnel_Name 56 string Redback
-ATTRIBUTE Bind_L2TP_Flow_Control 57 integer Redback
-ATTRIBUTE Bind_Sub_User_At_Context 58 string Redback
-ATTRIBUTE Bind_Sub_Password 59 string Redback
-ATTRIBUTE Ip_Host_Addr 60 string Redback
-ATTRIBUTE IP_TOS_Field 61 integer Redback
-ATTRIBUTE NAS_Real_Port 62 integer Redback
-ATTRIBUTE Tunnel_Session_Auth_Ctx 63 string Redback
-ATTRIBUTE Tunnel_Session_Auth_Service_Grp 64 string Redback
-ATTRIBUTE Tunnel_Rate_Limit_Rate 65 integer Redback
-ATTRIBUTE Tunnel_Rate_Limit_Burst 66 integer Redback
-ATTRIBUTE Tunnel_Police_Rate 67 integer Redback
-ATTRIBUTE Tunnel_Police_Burst 68 integer Redback
-ATTRIBUTE Tunnel_L2F_Second_Password 69 string Redback
-ATTRIBUTE TTY_Level_Max 72 integer Redback
-ATTRIBUTE TTY_Level_Start 73 integer Redback
-ATTRIBUTE Acct_Input_Octets_64 128 octets Redback
-ATTRIBUTE Acct_Output_Octets_64 129 octets Redback
-ATTRIBUTE Acct_Input_Packets_64 130 octets Redback
-ATTRIBUTE Acct_Output_Packets_64 131 octets Redback
-ATTRIBUTE Assigned_IP_Address 132 ipaddr Redback
-ATTRIBUTE Acct_Mcast_In_Octets 133 integer Redback
-ATTRIBUTE Acct_Mcast_Out_Octets 134 integer Redback
-ATTRIBUTE Acct_Mcast_In_Packets 135 integer Redback
-ATTRIBUTE Acct_Mcast_Out_Packets 136 integer Redback
-ATTRIBUTE LAC_Port 137 integer Redback
-ATTRIBUTE LAC_Real_Port 138 integer Redback
-ATTRIBUTE LAC_Port_Type 139 integer Redback
-ATTRIBUTE LAC_Real_Port_Type 140 integer Redback
-ATTRIBUTE Acct_Dyn_Ac_Ent 141 string Redback
-ATTRIBUTE Session_Error_Code 142 integer Redback
-ATTRIBUTE Session_Error_Msg 143 string Redback
+BEGIN-VENDOR Redback
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_RAW 1
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_ROUTE1483 2
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_AUTO1483 3
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_MULTI 4
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_BRIDGE1483 5
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP 6
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_SERIAL 7
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_NLPID 8
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_AUTO 9
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPPOE 10
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_L2TP 11
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_LLC 12
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_AUTO1490 13
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_MULTI 14
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_BRIDGE1490 15
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPP 16
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPP_AUTO 17
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPPOE 18
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_ROUTE1490 19
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_L2TP 20
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_L2TP_VC_MUXED 21
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH 22
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH_PPPOE 23
-VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH_MULTI 24
-VALUE PVC_Circuit_Padding AAA_CIRCUIT_PADDING 1
-VALUE PVC_Circuit_Padding AAA_CIRCUIT_NO_PADDING 2
-VALUE Bind_Type AAA_AUTH_BIND 1
-VALUE Bind_Type AAA_BYPASS_BIND 2
-VALUE Bind_Type AAA_INTERFACE_BIND 3
-VALUE Bind_Type AAA_SUBSCRIBE_BIND 4
-VALUE Bind_Type AAA_TUNNEL_BIND 5
-VALUE Bind_Type AAA_SESSION_BIND 6
-VALUE Bind_Type AAA_Q8021_BIND 7
-VALUE Bind_Type AAA_MULTI_BIND 8
-VALUE Bind_Auth_Protocol AAA_PPP_PAP 1
-VALUE Bind_Auth_Protocol AAA_PPP_CHAP 2
-VALUE Bind_Auth_Protocol AAA_PPP_CHAP_WAIT 3
-VALUE Bind_Auth_Protocol AAA_PPP_CHAP_PAP 4
-VALUE Bind_Auth_Protocol AAA_PPP_CHAP_WAIT_PAP 5
+ATTRIBUTE Client_DNS_Pri 1 ipaddr
+ATTRIBUTE Client_DNS_Sec 2 ipaddr
+ATTRIBUTE DHCP_Max_Leases 3 integer
+ATTRIBUTE Context_Name 4 string
+ATTRIBUTE Bridge_Group 5 string
+ATTRIBUTE BG_Aging_Time 6 string
+ATTRIBUTE BG_Path_Cost 7 string
+ATTRIBUTE BG_Span_Dis 8 string
+ATTRIBUTE BG_Trans_BPDU 9 string
+ATTRIBUTE Rate_Limit_Rate 10 integer
+ATTRIBUTE Rate_Limit_Burst 11 integer
+ATTRIBUTE Police_Rate 12 integer
+ATTRIBUTE Police_Burst 13 integer
+ATTRIBUTE Source_Validation 14 integer
+ATTRIBUTE Tunnel_Domain 15 integer
+ATTRIBUTE Tunnel_Local_Name 16 string
+ATTRIBUTE Tunnel_Remote_Name 17 string
+ATTRIBUTE Tunnel_Function 18 integer
+ATTRIBUTE Tunnel_Max_Sessions 21 integer
+ATTRIBUTE Tunnel_Max_Tunnels 22 integer
+ATTRIBUTE Tunnel_Session_Auth 23 integer
+ATTRIBUTE Tunnel_Window 24 integer
+ATTRIBUTE Tunnel_Retransmit 25 integer
+ATTRIBUTE Tunnel_Cmd_Timeout 26 integer
+ATTRIBUTE PPPOE_URL 27 string
+ATTRIBUTE PPPOE_MOTM 28 string
+ATTRIBUTE Tunnel_Group 29 integer
+ATTRIBUTE Tunnel_Context 30 string
+ATTRIBUTE Tunnel_Algorithm 31 integer
+ATTRIBUTE Tunnel_Deadtime 32 integer
+ATTRIBUTE Mcast_Send 33 integer
+ATTRIBUTE Mcast_Receive 34 integer
+ATTRIBUTE Mcast_MaxGroups 35 integer
+ATTRIBUTE Ip_Address_Pool_Name 36 string
+ATTRIBUTE Tunnel_DNIS 37 integer
+ATTRIBUTE Medium_Type 38 integer
+ATTRIBUTE PVC_Encapsulation_Type 39 integer
+ATTRIBUTE PVC_Profile_Name 40 string
+ATTRIBUTE PVC_Circuit_Padding 41 integer
+ATTRIBUTE Bind_Type 42 integer
+ATTRIBUTE Bind_Auth_Protocol 43 integer
+ATTRIBUTE Bind_Auth_Max_Sessions 44 integer
+ATTRIBUTE Bind_Bypass_Bypass 45 string
+ATTRIBUTE Bind_Auth_Context 46 string
+ATTRIBUTE Bind_Auth_Service_Grp 47 string
+ATTRIBUTE Bind_Bypass_Context 48 string
+ATTRIBUTE Bind_Int_Context 49 string
+ATTRIBUTE Bind_Tun_Context 50 string
+ATTRIBUTE Bind_Ses_Context 51 string
+ATTRIBUTE Bind_Dot1q_Slot 52 integer
+ATTRIBUTE Bind_Dot1q_Port 53 integer
+ATTRIBUTE Bind_Dot1q_Vlan_Tag_Id 54 integer
+ATTRIBUTE Bind_Int_Interface_Name 55 string
+ATTRIBUTE Bind_L2TP_Tunnel_Name 56 string
+ATTRIBUTE Bind_L2TP_Flow_Control 57 integer
+ATTRIBUTE Bind_Sub_User_At_Context 58 string
+ATTRIBUTE Bind_Sub_Password 59 string
+ATTRIBUTE Ip_Host_Addr 60 string
+ATTRIBUTE IP_TOS_Field 61 integer
+ATTRIBUTE NAS_Real_Port 62 integer
+ATTRIBUTE Tunnel_Session_Auth_Ctx 63 string
+ATTRIBUTE Tunnel_Session_Auth_Service_Grp 64 string
+ATTRIBUTE Tunnel_Rate_Limit_Rate 65 integer
+ATTRIBUTE Tunnel_Rate_Limit_Burst 66 integer
+ATTRIBUTE Tunnel_Police_Rate 67 integer
+ATTRIBUTE Tunnel_Police_Burst 68 integer
+ATTRIBUTE Tunnel_L2F_Second_Password 69 string
+ATTRIBUTE TTY_Level_Max 72 integer
+ATTRIBUTE TTY_Level_Start 73 integer
+ATTRIBUTE Qos-Policy-Policing 87 string
+ATTRIBUTE Qos-Policy-Metering 88 string
+ATTRIBUTE Qos-Policy-Queuing 89 string
+ATTRIBUTE Igmp-Service-Profile 90 string
+ATTRIBUTE Sub-Profile-Name 91 string
+ATTRIBUTE Forward-Policy 92 string
+ATTRIBUTE Reauth-String 94 string
+ATTRIBUTE Reauth-More 95 integer
+ATTRIBUTE Agent-Remote-Id 96 string
+ATTRIBUTE Agent-Circuit-Id 97 string
+ATTRIBUTE Platform-Type 98 integer
+ATTRIBUTE RB-Client-NBNS-Pri 99 ipaddr
+ATTRIBUTE RB-Client-NBNS-Sec 100 ipaddr
+ATTRIBUTE Shaping-Profile-Name 101 string
+ATTRIBUTE IP-Interface 104 string
+ATTRIBUTE NAT-Policy-Name 105 string
+ATTRIBUTE HTTP-Redirect-Profile-Name 107 string
+ATTRIBUTE OS-Version 112 string
+ATTRIBUTE Session-Traffic-Limit 113 string
+ATTRIBUTE Acct_Input_Octets_64 128 octets
+ATTRIBUTE Acct_Output_Octets_64 129 octets
+ATTRIBUTE Acct_Input_Packets_64 130 octets
+ATTRIBUTE Acct_Output_Packets_64 131 octets
+ATTRIBUTE Assigned_IP_Address 132 ipaddr
+ATTRIBUTE Acct_Mcast_In_Octets 133 integer
+ATTRIBUTE Acct_Mcast_Out_Octets 134 integer
+ATTRIBUTE Acct_Mcast_In_Packets 135 integer
+ATTRIBUTE Acct_Mcast_Out_Packets 136 integer
+ATTRIBUTE LAC_Port 137 integer
+ATTRIBUTE LAC_Real_Port 138 integer
+ATTRIBUTE LAC_Port_Type 139 integer
+ATTRIBUTE LAC_Real_Port_Type 140 integer
+ATTRIBUTE Acct_Dyn_Ac_Ent 141 string
+ATTRIBUTE Session_Error_Code 142 integer
+ATTRIBUTE Session_Error_Msg 143 string
-VALUE Tunnel_Function LAC-Only 1
-VALUE Tunnel_Function LNS-Only 2
-VALUE Tunnel_Function LAC-LNS 3
-VALUE Tunnel_Session_auth CHAP 1
-VALUE Tunnel_Session_auth PAP 2
-VALUE Tunnel_Session_auth CHAP-PAP 3
-VALUE Mcast_Send NO-SEND 1
-VALUE Mcast_Send SEND 2
-VALUE Mcast_Send UNSOLICITED-SEND 3
-VALUE Mcast_Receive NO-RECEIVE 1
-VALUE Mcast_Receive RECEIVE 2
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_RAW 1
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_ROUTE1483 2
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_AUTO1483 3
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_MULTI 4
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_BRIDGE1483 5
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP 6
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_SERIAL 7
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_NLPID 8
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_AUTO 9
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPPOE 10
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_L2TP 11
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ATM_PPP_LLC 12
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_AUTO1490 13
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_MULTI 14
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_BRIDGE1490 15
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPP 16
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPP_AUTO 17
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_PPPOE 18
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_ROUTE1490 19
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_FRAME_L2TP 20
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_L2TP_VC_MUXED 21
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH 22
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH_PPPOE 23
+VALUE PVC_Encapsulation_Type AAA_ENCAPS_ETH_MULTI 24
+VALUE PVC_Circuit_Padding AAA_CIRCUIT_PADDING 1
+VALUE PVC_Circuit_Padding AAA_CIRCUIT_NO_PADDING 2
+VALUE Bind_Type AAA_AUTH_BIND 1
+VALUE Bind_Type AAA_BYPASS_BIND 2
+VALUE Bind_Type AAA_INTERFACE_BIND 3
+VALUE Bind_Type AAA_SUBSCRIBE_BIND 4
+VALUE Bind_Type AAA_TUNNEL_BIND 5
+VALUE Bind_Type AAA_SESSION_BIND 6
+VALUE Bind_Type AAA_Q8021_BIND 7
+VALUE Bind_Type AAA_MULTI_BIND 8
+VALUE Bind_Auth_Protocol AAA_PPP_PAP 1
+VALUE Bind_Auth_Protocol AAA_PPP_CHAP 2
+VALUE Bind_Auth_Protocol AAA_PPP_CHAP_WAIT 3
+VALUE Bind_Auth_Protocol AAA_PPP_CHAP_PAP 4
+VALUE Bind_Auth_Protocol AAA_PPP_CHAP_WAIT_PAP 5
-VALUE Tunnel_DNIS DNIS 1
-VALUE Tunnel_DNIS DNIS-Only 2
+VALUE Tunnel_Function LAC-Only 1
+VALUE Tunnel_Function LNS-Only 2
+VALUE Tunnel_Function LAC-LNS 3
+VALUE Tunnel_Session_auth CHAP 1
+VALUE Tunnel_Session_auth PAP 2
+VALUE Tunnel_Session_auth CHAP-PAP 3
+VALUE Mcast_Send NO-SEND 1
+VALUE Mcast_Send SEND 2
+VALUE Mcast_Send UNSOLICITED-SEND 3
+VALUE Mcast_Receive NO-RECEIVE 1
+VALUE Mcast_Receive RECEIVE 2
-VALUE LAC_Port_Type NAS_PORT_TYPE_10BT 40
-VALUE LAC_Port_Type NAS_PORT_TYPE_100BT 41
-VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_FR 42
-VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_ATM 43
-VALUE LAC_Port_Type NAS_PORT_TYPE_OC3 44
-VALUE LAC_Port_Type NAS_PORT_TYPE_HSSI 45
-VALUE LAC_Port_Type NAS_PORT_TYPE_EIA530 46
-VALUE LAC_Port_Type NAS_PORT_TYPE_T1 47
-VALUE LAC_Port_Type NAS_PORT_TYPE_CHAN_T3 48
-VALUE LAC_Port_Type NAS_PORT_TYPE_DS1_FR 49
-VALUE LAC_Port_Type NAS_PORT_TYPE_E3_ATM 50
-VALUE LAC_Port_Type NAS_PORT_TYPE_IMA_ATM 51
-VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_ATM_2 52
-VALUE LAC_Port_Type NAS_PORT_TYPE_OC3_ATM_2 53
-VALUE LAC_Port_Type NAS_PORT_TYPE_1000BSX 54
-VALUE LAC_Port_Type NAS_PORT_TYPE_E1_FR 55
-VALUE LAC_Port_Type NAS_PORT_TYPE_E1_ATM 56
-VALUE LAC_Port_Type NAS_PORT_TYPE_E3_FR 57
-VALUE LAC_Port_Type NAS_PORT_TYPE_OC3_POS 58
-VALUE LAC_Port_Type NAS_PORT_TYPE_OC12_POS 59
-VALUE LAC_Port_Type NAS_PORT_TYPE_PPPOE 60
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_10BT 40
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_100BT 41
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_FR 42
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_ATM 43
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3 44
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_HSSI 45
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_EIA530 46
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_T1 47
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_CHAN_T3 48
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS1_FR 49
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E3_ATM 50
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_IMA_ATM 51
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_ATM_2 52
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3_ATM_2 53
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_1000BSX 54
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E1_FR 55
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E1_ATM 56
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E3_FR 57
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3_POS 58
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC12_POS 59
-VALUE LAC_Real_Port_Type NAS_PORT_TYPE_PPPOE 60
+VALUE Tunnel_DNIS DNIS 1
+VALUE Tunnel_DNIS DNIS-Only 2
+
+VALUE LAC_Port_Type NAS_PORT_TYPE_10BT 40
+VALUE LAC_Port_Type NAS_PORT_TYPE_100BT 41
+VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_FR 42
+VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_ATM 43
+VALUE LAC_Port_Type NAS_PORT_TYPE_OC3 44
+VALUE LAC_Port_Type NAS_PORT_TYPE_HSSI 45
+VALUE LAC_Port_Type NAS_PORT_TYPE_EIA530 46
+VALUE LAC_Port_Type NAS_PORT_TYPE_T1 47
+VALUE LAC_Port_Type NAS_PORT_TYPE_CHAN_T3 48
+VALUE LAC_Port_Type NAS_PORT_TYPE_DS1_FR 49
+VALUE LAC_Port_Type NAS_PORT_TYPE_E3_ATM 50
+VALUE LAC_Port_Type NAS_PORT_TYPE_IMA_ATM 51
+VALUE LAC_Port_Type NAS_PORT_TYPE_DS3_ATM_2 52
+VALUE LAC_Port_Type NAS_PORT_TYPE_OC3_ATM_2 53
+VALUE LAC_Port_Type NAS_PORT_TYPE_1000BSX 54
+VALUE LAC_Port_Type NAS_PORT_TYPE_E1_FR 55
+VALUE LAC_Port_Type NAS_PORT_TYPE_E1_ATM 56
+VALUE LAC_Port_Type NAS_PORT_TYPE_E3_FR 57
+VALUE LAC_Port_Type NAS_PORT_TYPE_OC3_POS 58
+VALUE LAC_Port_Type NAS_PORT_TYPE_OC12_POS 59
+VALUE LAC_Port_Type NAS_PORT_TYPE_PPPOE 60
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_10BT 40
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_100BT 41
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_FR 42
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_ATM 43
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3 44
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_HSSI 45
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_EIA530 46
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_T1 47
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_CHAN_T3 48
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS1_FR 49
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E3_ATM 50
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_IMA_ATM 51
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_DS3_ATM_2 52
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3_ATM_2 53
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_1000BSX 54
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E1_FR 55
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E1_ATM 56
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_E3_FR 57
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC3_POS 58
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_OC12_POS 59
+VALUE LAC_Real_Port_Type NAS_PORT_TYPE_PPPOE 60
#
# New names.
#
-ATTRIBUTE Client-DNS-Pri 1 ipaddr Redback
-ATTRIBUTE Client-DNS-Sec 2 ipaddr Redback
-ATTRIBUTE DHCP-Max-Leases 3 integer Redback
-ATTRIBUTE Context-Name 4 string Redback
-ATTRIBUTE Bridge-Group 5 string Redback
-ATTRIBUTE BG-Aging-Time 6 string Redback
-ATTRIBUTE BG-Path-Cost 7 string Redback
-ATTRIBUTE BG-Span-Dis 8 string Redback
-ATTRIBUTE BG-Trans-BPDU 9 string Redback
-ATTRIBUTE Rate-Limit-Rate 10 integer Redback
-ATTRIBUTE Rate-Limit-Burst 11 integer Redback
-ATTRIBUTE Police-Rate 12 integer Redback
-ATTRIBUTE Police-Burst 13 integer Redback
-ATTRIBUTE Source-Validation 14 integer Redback
-ATTRIBUTE Tunnel-Domain 15 integer Redback
-ATTRIBUTE Tunnel-Local-Name 16 string Redback
-ATTRIBUTE Tunnel-Remote-Name 17 string Redback
-ATTRIBUTE Tunnel-Function 18 integer Redback
-ATTRIBUTE Tunnel-Max-Sessions 21 integer Redback
-ATTRIBUTE Tunnel-Max-Tunnels 22 integer Redback
-ATTRIBUTE Tunnel-Session-Auth 23 integer Redback
-ATTRIBUTE Tunnel-Window 24 integer Redback
-ATTRIBUTE Tunnel-Retransmit 25 integer Redback
-ATTRIBUTE Tunnel-Cmd-Timeout 26 integer Redback
-ATTRIBUTE PPPOE-URL 27 string Redback
-ATTRIBUTE PPPOE-MOTM 28 string Redback
-ATTRIBUTE Tunnel-Group 29 integer Redback
-ATTRIBUTE Tunnel-Context 30 string Redback
-ATTRIBUTE Tunnel-Algorithm 31 integer Redback
-ATTRIBUTE Tunnel-Deadtime 32 integer Redback
-ATTRIBUTE Mcast-Send 33 integer Redback
-ATTRIBUTE Mcast-Receive 34 integer Redback
-ATTRIBUTE Mcast-MaxGroups 35 integer Redback
-ATTRIBUTE Ip-Address-Pool-Name 36 string Redback
-ATTRIBUTE Tunnel-DNIS 37 integer Redback
-ATTRIBUTE Medium-Type 38 integer Redback
-ATTRIBUTE PVC-Encapsulation-Type 39 integer Redback
-ATTRIBUTE PVC-Profile-Name 40 string Redback
-ATTRIBUTE PVC-Circuit-Padding 41 integer Redback
-ATTRIBUTE Bind-Type 42 integer Redback
-ATTRIBUTE Bind-Auth-Protocol 43 integer Redback
-ATTRIBUTE Bind-Auth-Max-Sessions 44 integer Redback
-ATTRIBUTE Bind-Bypass-Bypass 45 string Redback
-ATTRIBUTE Bind-Auth-Context 46 string Redback
-ATTRIBUTE Bind-Auth-Service-Grp 47 string Redback
-ATTRIBUTE Bind-Bypass-Context 48 string Redback
-ATTRIBUTE Bind-Int-Context 49 string Redback
-ATTRIBUTE Bind-Tun-Context 50 string Redback
-ATTRIBUTE Bind-Ses-Context 51 string Redback
-ATTRIBUTE Bind-Dot1q-Slot 52 integer Redback
-ATTRIBUTE Bind-Dot1q-Port 53 integer Redback
-ATTRIBUTE Bind-Dot1q-Vlan-Tag-Id 54 integer Redback
-ATTRIBUTE Bind-Int-Interface-Name 55 string Redback
-ATTRIBUTE Bind-L2TP-Tunnel-Name 56 string Redback
-ATTRIBUTE Bind-L2TP-Flow-Control 57 integer Redback
-ATTRIBUTE Bind-Sub-User-At-Context 58 string Redback
-ATTRIBUTE Bind-Sub-Password 59 string Redback
-ATTRIBUTE Ip-Host-Addr 60 string Redback
-ATTRIBUTE IP-TOS-Field 61 integer Redback
-ATTRIBUTE NAS-Real-Port 62 integer Redback
-ATTRIBUTE Tunnel-Session-Auth-Ctx 63 string Redback
-ATTRIBUTE Tunnel-Session-Auth-Service-Grp 64 string Redback
-ATTRIBUTE Tunnel-Rate-Limit-Rate 65 integer Redback
-ATTRIBUTE Tunnel-Rate-Limit-Burst 66 integer Redback
-ATTRIBUTE Tunnel-Police-Rate 67 integer Redback
-ATTRIBUTE Tunnel-Police-Burst 68 integer Redback
-ATTRIBUTE Tunnel-L2F-Second-Password 69 string Redback
-ATTRIBUTE TTY-Level-Max 72 integer Redback
-ATTRIBUTE TTY-Level-Start 73 integer Redback
-ATTRIBUTE Acct-Input-Octets-64 128 octets Redback
-ATTRIBUTE Acct-Output-Octets-64 129 octets Redback
-ATTRIBUTE Acct-Input-Packets-64 130 octets Redback
-ATTRIBUTE Acct-Output-Packets-64 131 octets Redback
-ATTRIBUTE Assigned-IP-Address 132 ipaddr Redback
-ATTRIBUTE Acct-Mcast-In-Octets 133 integer Redback
-ATTRIBUTE Acct-Mcast-Out-Octets 134 integer Redback
-ATTRIBUTE Acct-Mcast-In-Packets 135 integer Redback
-ATTRIBUTE Acct-Mcast-Out-Packets 136 integer Redback
-ATTRIBUTE LAC-Port 137 integer Redback
-ATTRIBUTE LAC-Real-Port 138 integer Redback
-ATTRIBUTE LAC-Port-Type 139 integer Redback
-ATTRIBUTE LAC-Real-Port-Type 140 integer Redback
-ATTRIBUTE Acct-Dyn-Ac-Ent 141 string Redback
-ATTRIBUTE Session-Error-Code 142 integer Redback
-ATTRIBUTE Session-Error-Msg 143 string Redback
+ATTRIBUTE Client-DNS-Pri 1 ipaddr
+ATTRIBUTE Client-DNS-Sec 2 ipaddr
+ATTRIBUTE DHCP-Max-Leases 3 integer
+ATTRIBUTE Context-Name 4 string
+ATTRIBUTE Bridge-Group 5 string
+ATTRIBUTE BG-Aging-Time 6 string
+ATTRIBUTE BG-Path-Cost 7 string
+ATTRIBUTE BG-Span-Dis 8 string
+ATTRIBUTE BG-Trans-BPDU 9 string
+ATTRIBUTE Rate-Limit-Rate 10 integer
+ATTRIBUTE Rate-Limit-Burst 11 integer
+ATTRIBUTE Police-Rate 12 integer
+ATTRIBUTE Police-Burst 13 integer
+ATTRIBUTE Source-Validation 14 integer
+ATTRIBUTE Tunnel-Domain 15 integer
+ATTRIBUTE Tunnel-Local-Name 16 string
+ATTRIBUTE Tunnel-Remote-Name 17 string
+ATTRIBUTE Tunnel-Function 18 integer
+ATTRIBUTE Tunnel-Max-Sessions 21 integer
+ATTRIBUTE Tunnel-Max-Tunnels 22 integer
+ATTRIBUTE Tunnel-Session-Auth 23 integer
+ATTRIBUTE Tunnel-Window 24 integer
+ATTRIBUTE Tunnel-Retransmit 25 integer
+ATTRIBUTE Tunnel-Cmd-Timeout 26 integer
+ATTRIBUTE PPPOE-URL 27 string
+ATTRIBUTE PPPOE-MOTM 28 string
+ATTRIBUTE Tunnel-Group 29 integer
+ATTRIBUTE Tunnel-Context 30 string
+ATTRIBUTE Tunnel-Algorithm 31 integer
+ATTRIBUTE Tunnel-Deadtime 32 integer
+ATTRIBUTE Mcast-Send 33 integer
+ATTRIBUTE Mcast-Receive 34 integer
+ATTRIBUTE Mcast-MaxGroups 35 integer
+ATTRIBUTE Ip-Address-Pool-Name 36 string
+ATTRIBUTE Tunnel-DNIS 37 integer
+ATTRIBUTE Medium-Type 38 integer
+ATTRIBUTE PVC-Encapsulation-Type 39 integer
+ATTRIBUTE PVC-Profile-Name 40 string
+ATTRIBUTE PVC-Circuit-Padding 41 integer
+ATTRIBUTE Bind-Type 42 integer
+ATTRIBUTE Bind-Auth-Protocol 43 integer
+ATTRIBUTE Bind-Auth-Max-Sessions 44 integer
+ATTRIBUTE Bind-Bypass-Bypass 45 string
+ATTRIBUTE Bind-Auth-Context 46 string
+ATTRIBUTE Bind-Auth-Service-Grp 47 string
+ATTRIBUTE Bind-Bypass-Context 48 string
+ATTRIBUTE Bind-Int-Context 49 string
+ATTRIBUTE Bind-Tun-Context 50 string
+ATTRIBUTE Bind-Ses-Context 51 string
+ATTRIBUTE Bind-Dot1q-Slot 52 integer
+ATTRIBUTE Bind-Dot1q-Port 53 integer
+ATTRIBUTE Bind-Dot1q-Vlan-Tag-Id 54 integer
+ATTRIBUTE Bind-Int-Interface-Name 55 string
+ATTRIBUTE Bind-L2TP-Tunnel-Name 56 string
+ATTRIBUTE Bind-L2TP-Flow-Control 57 integer
+ATTRIBUTE Bind-Sub-User-At-Context 58 string
+ATTRIBUTE Bind-Sub-Password 59 string
+ATTRIBUTE Ip-Host-Addr 60 string
+ATTRIBUTE IP-TOS-Field 61 integer
+ATTRIBUTE NAS-Real-Port 62 integer
+ATTRIBUTE Tunnel-Session-Auth-Ctx 63 string
+ATTRIBUTE Tunnel-Session-Auth-Service-Grp 64 string
+ATTRIBUTE Tunnel-Rate-Limit-Rate 65 integer
+ATTRIBUTE Tunnel-Rate-Limit-Burst 66 integer
+ATTRIBUTE Tunnel-Police-Rate 67 integer
+ATTRIBUTE Tunnel-Police-Burst 68 integer
+ATTRIBUTE Tunnel-L2F-Second-Password 69 string
+ATTRIBUTE ACL-Definition 70 string
+ATTRIBUTE PPPoE-IP-Route-Add 71 string
+ATTRIBUTE TTY-Level-Max 72 integer
+ATTRIBUTE TTY-Level-Start 73 integer
+ATTRIBUTE Tunnel-Checksum 74 integer
+ATTRIBUTE Tunnel-Profile 75 string
+ATTRIBUTE Tunnel-Client-VPN 78 string
+ATTRIBUTE Tunnel-Server-VPN 79 string
+ATTRIBUTE Tunnel-Client-Rhost 80 string
+ATTRIBUTE Tunnel-Server-Rhost 81 string
+ATTRIBUTE Tunnel-Client-Int-Addr 82 ipaddr
+ATTRIBUTE Tunnel-Server-Int-Addr 83 ipaddr
+ATTRIBUTE Agent-Remote-Id 96 string
+ATTRIBUTE Agent-Circuit-Id 97 string
+ATTRIBUTE Platform-Type 98 integer
+ATTRIBUTE Client-NBNS-Pri 99 ipaddr
+ATTRIBUTE Client-NBNS-Sec 100 ipaddr
+ATTRIBUTE BG-Cct-Addr-Max 103 integer
+ATTRIBUTE IP-Interface-Name 104 string
+ATTRIBUTE Rate-Limit-Excess-Burst 121 octets
+ATTRIBUTE Police-Excess-Burst 122 octets
+ATTRIBUTE Tunnel-Rate-Limit-Excess-Burst 123 octets
+ATTRIBUTE Tunnel-Police-Excess-Burst 124 octets
+ATTRIBUTE Acct-Input-Octets-64 128 octets
+ATTRIBUTE Acct-Output-Octets-64 129 octets
+ATTRIBUTE Acct-Input-Packets-64 130 octets
+ATTRIBUTE Acct-Output-Packets-64 131 octets
+ATTRIBUTE Assigned-IP-Address 132 ipaddr
+ATTRIBUTE Acct-Mcast-In-Octets-64 133 octets
+ATTRIBUTE Acct-Mcast-Out-Octets-64 134 octets
+ATTRIBUTE Acct-Mcast-In-Packets-64 135 octets
+ATTRIBUTE Acct-Mcast-Out-Packets-64 136 octets
+ATTRIBUTE LAC-Port 137 integer
+ATTRIBUTE LAC-Real-Port 138 integer
+ATTRIBUTE LAC-Port-Type 139 integer
+ATTRIBUTE LAC-Real-Port-Type 140 integer
+ATTRIBUTE Acct-Dyn-Ac-Ent 141 string
+ATTRIBUTE Session-Error-Code 142 integer
+ATTRIBUTE Session-Error-Msg 143 string
+ATTRIBUTE Acct-Update-Reason 144 integer
+ATTRIBUTE Mac-Addr 145 string
+ATTRIBUTE Vlan-Source-Info 146 string
+ATTRIBUTE Acct-Mcast-In-Octets 147 integer
+ATTRIBUTE Acct-Mcast-Out-Octets 148 integer
+ATTRIBUTE Acct-Mcast-In-Packets 149 integer
+ATTRIBUTE Acct-Mcast-Out-Packets 150 integer
+ATTRIBUTE Reauth-Session-Id 151 string
+
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-RAW 1
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-ROUTE1483 2
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-AUTO1483 3
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-MULTI 4
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-BRIDGE1483 5
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP 6
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-SERIAL 7
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-NLPID 8
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-AUTO 9
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPPOE 10
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-L2TP 11
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-LLC 12
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-AUTO1490 13
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-MULTI 14
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-BRIDGE1490 15
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPP 16
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPP-AUTO 17
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPPOE 18
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-ROUTE1490 19
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-L2TP 20
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-L2TP-VC-MUXED 21
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH 22
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH-PPPOE 23
+VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH-MULTI 24
+VALUE PVC-Circuit-Padding AAA-CIRCUIT-PADDING 1
+VALUE PVC-Circuit-Padding AAA-CIRCUIT-NO-PADDING 2
+VALUE Bind-Type AAA-AUTH-BIND 1
+VALUE Bind-Type AAA-BYPASS-BIND 2
+VALUE Bind-Type AAA-INTERFACE-BIND 3
+VALUE Bind-Type AAA-SUBSCRIBE-BIND 4
+VALUE Bind-Type AAA-TUNNEL-BIND 5
+VALUE Bind-Type AAA-SESSION-BIND 6
+VALUE Bind-Type AAA-Q8021-BIND 7
+VALUE Bind-Type AAA-MULTI-BIND 8
+VALUE Bind-Auth-Protocol AAA-PPP-PAP 1
+VALUE Bind-Auth-Protocol AAA-PPP-CHAP 2
+VALUE Bind-Auth-Protocol AAA-PPP-CHAP-WAIT 3
+VALUE Bind-Auth-Protocol AAA-PPP-CHAP-PAP 4
+VALUE Bind-Auth-Protocol AAA-PPP-CHAP-WAIT-PAP 5
+
+VALUE Tunnel-Function LAC-Only 1
+VALUE Tunnel-Function LNS-Only 2
+VALUE Tunnel-Function LAC-LNS 3
+VALUE Tunnel-Session-auth CHAP 1
+VALUE Tunnel-Session-auth PAP 2
+VALUE Tunnel-Session-auth CHAP-PAP 3
+VALUE Mcast-Send NO-SEND 1
+VALUE Mcast-Send SEND 2
+VALUE Mcast-Send UNSOLICITED-SEND 3
+VALUE Mcast-Receive NO-RECEIVE 1
+VALUE Mcast-Receive RECEIVE 2
+
+VALUE Tunnel-DNIS DNIS 1
+VALUE Tunnel-DNIS DNIS-Only 2
+
+VALUE Platform-Type SMS 1
+VALUE Platform-Type SmartEdge-800 2
+
+VALUE Medium-Type DSL 11
+VALUE Medium-Type Cable 12
+VALUE Medium-Type Wireless 13
+VALUE Medium-Type Satellite 14
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-RAW 1
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-ROUTE1483 2
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-AUTO1483 3
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-MULTI 4
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-BRIDGE1483 5
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP 6
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-SERIAL 7
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-NLPID 8
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-AUTO 9
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPPOE 10
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-L2TP 11
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ATM-PPP-LLC 12
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-AUTO1490 13
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-MULTI 14
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-BRIDGE1490 15
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPP 16
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPP-AUTO 17
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-PPPOE 18
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-ROUTE1490 19
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-FRAME-L2TP 20
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-L2TP-VC-MUXED 21
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH 22
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH-PPPOE 23
-VALUE PVC-Encapsulation-Type AAA-ENCAPS-ETH-MULTI 24
-VALUE PVC-Circuit-Padding AAA-CIRCUIT-PADDING 1
-VALUE PVC-Circuit-Padding AAA-CIRCUIT-NO-PADDING 2
-VALUE Bind-Type AAA-AUTH-BIND 1
-VALUE Bind-Type AAA-BYPASS-BIND 2
-VALUE Bind-Type AAA-INTERFACE-BIND 3
-VALUE Bind-Type AAA-SUBSCRIBE-BIND 4
-VALUE Bind-Type AAA-TUNNEL-BIND 5
-VALUE Bind-Type AAA-SESSION-BIND 6
-VALUE Bind-Type AAA-Q8021-BIND 7
-VALUE Bind-Type AAA-MULTI-BIND 8
-VALUE Bind-Auth-Protocol AAA-PPP-PAP 1
-VALUE Bind-Auth-Protocol AAA-PPP-CHAP 2
-VALUE Bind-Auth-Protocol AAA-PPP-CHAP-WAIT 3
-VALUE Bind-Auth-Protocol AAA-PPP-CHAP-PAP 4
-VALUE Bind-Auth-Protocol AAA-PPP-CHAP-WAIT-PAP 5
+VALUE LAC-Port-Type NAS-PORT-TYPE-10BT 40
+VALUE LAC-Port-Type NAS-PORT-TYPE-100BT 41
+VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-FR 42
+VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-ATM 43
+VALUE LAC-Port-Type NAS-PORT-TYPE-OC3 44
+VALUE LAC-Port-Type NAS-PORT-TYPE-HSSI 45
+VALUE LAC-Port-Type NAS-PORT-TYPE-EIA530 46
+VALUE LAC-Port-Type NAS-PORT-TYPE-T1 47
+VALUE LAC-Port-Type NAS-PORT-TYPE-CHAN-T3 48
+VALUE LAC-Port-Type NAS-PORT-TYPE-DS1-FR 49
+VALUE LAC-Port-Type NAS-PORT-TYPE-E3-ATM 50
+VALUE LAC-Port-Type NAS-PORT-TYPE-IMA-ATM 51
+VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-ATM-2 52
+VALUE LAC-Port-Type NAS-PORT-TYPE-OC3-ATM-2 53
+VALUE LAC-Port-Type NAS-PORT-TYPE-1000BSX 54
+VALUE LAC-Port-Type NAS-PORT-TYPE-E1-FR 55
+VALUE LAC-Port-Type NAS-PORT-TYPE-E1-ATM 56
+VALUE LAC-Port-Type NAS-PORT-TYPE-E3-FR 57
+VALUE LAC-Port-Type NAS-PORT-TYPE-OC3-POS 58
+VALUE LAC-Port-Type NAS-PORT-TYPE-OC12-POS 59
+VALUE LAC-Port-Type NAS-PORT-TYPE-PPPOE 60
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-10BT 40
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-100BT 41
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-FR 42
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-ATM 43
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3 44
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-HSSI 45
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-EIA530 46
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-T1 47
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-CHAN-T3 48
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS1-FR 49
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E3-ATM 50
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-IMA-ATM 51
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-ATM-2 52
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3-ATM-2 53
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-1000BSX 54
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E1-FR 55
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E1-ATM 56
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E3-FR 57
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3-POS 58
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC12-POS 59
+VALUE LAC-Real-Port-Type NAS-PORT-TYPE-PPPOE 60
-VALUE Tunnel-Function LAC-Only 1
-VALUE Tunnel-Function LNS-Only 2
-VALUE Tunnel-Function LAC-LNS 3
-VALUE Tunnel-Session-auth CHAP 1
-VALUE Tunnel-Session-auth PAP 2
-VALUE Tunnel-Session-auth CHAP-PAP 3
-VALUE Mcast-Send NO-SEND 1
-VALUE Mcast-Send SEND 2
-VALUE Mcast-Send UNSOLICITED-SEND 3
-VALUE Mcast-Receive NO-RECEIVE 1
-VALUE Mcast-Receive RECEIVE 2
+# Although Redback uses - instead of _ in the Attributes, these values are listed
+# with _ in the latest (6.1.4.4) documentation, so I have entered them as so
+# graeme
-VALUE Tunnel-DNIS DNIS 1
-VALUE Tunnel-DNIS DNIS-Only 2
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_SESSION_UP 1
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_SESSION_DOWN 2
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_PERIODIC 3
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_DYN_AC_ENT_START 4
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_DYN_AC_ENT_STOP 5
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_DYN_AC_ENT_TIMEOUT 6
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_SUBSCRIBER_REAUTHOR 7
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_PPP_IPCP_UP 8
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_PPP_MP_LINK_UP 9
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_DHCP_IP_ADDR_GRANTED 10
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_DHCP_IP_ADDR_RELEASED 11
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_ACL_TIMERED_ACTION 12
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_ACL_ACTION 13
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_CMD 14
+VALUE Acct-Update-Reason AAA_LOAD_ACCT_TEST 15
-VALUE LAC-Port-Type NAS-PORT-TYPE-10BT 40
-VALUE LAC-Port-Type NAS-PORT-TYPE-100BT 41
-VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-FR 42
-VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-ATM 43
-VALUE LAC-Port-Type NAS-PORT-TYPE-OC3 44
-VALUE LAC-Port-Type NAS-PORT-TYPE-HSSI 45
-VALUE LAC-Port-Type NAS-PORT-TYPE-EIA530 46
-VALUE LAC-Port-Type NAS-PORT-TYPE-T1 47
-VALUE LAC-Port-Type NAS-PORT-TYPE-CHAN-T3 48
-VALUE LAC-Port-Type NAS-PORT-TYPE-DS1-FR 49
-VALUE LAC-Port-Type NAS-PORT-TYPE-E3-ATM 50
-VALUE LAC-Port-Type NAS-PORT-TYPE-IMA-ATM 51
-VALUE LAC-Port-Type NAS-PORT-TYPE-DS3-ATM-2 52
-VALUE LAC-Port-Type NAS-PORT-TYPE-OC3-ATM-2 53
-VALUE LAC-Port-Type NAS-PORT-TYPE-1000BSX 54
-VALUE LAC-Port-Type NAS-PORT-TYPE-E1-FR 55
-VALUE LAC-Port-Type NAS-PORT-TYPE-E1-ATM 56
-VALUE LAC-Port-Type NAS-PORT-TYPE-E3-FR 57
-VALUE LAC-Port-Type NAS-PORT-TYPE-OC3-POS 58
-VALUE LAC-Port-Type NAS-PORT-TYPE-OC12-POS 59
-VALUE LAC-Port-Type NAS-PORT-TYPE-PPPOE 60
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-10BT 40
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-100BT 41
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-FR 42
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-ATM 43
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3 44
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-HSSI 45
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-EIA530 46
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-T1 47
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-CHAN-T3 48
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS1-FR 49
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E3-ATM 50
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-IMA-ATM 51
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-DS3-ATM-2 52
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3-ATM-2 53
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-1000BSX 54
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E1-FR 55
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E1-ATM 56
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-E3-FR 57
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC3-POS 58
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-OC12-POS 59
-VALUE LAC-Real-Port-Type NAS-PORT-TYPE-PPPOE 60
+END-VENDOR Redback
+# -*- text -*-
#
# http://www.redcreek.com
# $Id$
#
-VENDOR RedCreek 1958
+VENDOR RedCreek 1958
-ATTRIBUTE RedCreek-Tunneled-IP-Addr 5 ipaddr RedCreek
-ATTRIBUTE RedCreek-Tunneled-IP-Netmask 6 ipaddr RedCreek
-ATTRIBUTE RedCreek-Tunneled-Gateway 7 ipaddr RedCreek
-ATTRIBUTE RedCreek-Tunneled-DNS-Server 8 string RedCreek
-ATTRIBUTE RedCreek-Tunneled-WINS-Server1 9 string RedCreek
-ATTRIBUTE RedCreek-Tunneled-WINS-Server2 10 string RedCreek
-ATTRIBUTE RedCreek-Tunneled-HostName 11 string RedCreek
-ATTRIBUTE RedCreek-Tunneled-DomainName 12 string RedCreek
-ATTRIBUTE RedCreek-Tunneled-Search-List 13 string RedCreek
+BEGIN-VENDOR RedCreek
+
+ATTRIBUTE RedCreek-Tunneled-IP-Addr 5 ipaddr
+ATTRIBUTE RedCreek-Tunneled-IP-Netmask 6 ipaddr
+ATTRIBUTE RedCreek-Tunneled-Gateway 7 ipaddr
+ATTRIBUTE RedCreek-Tunneled-DNS-Server 8 string
+ATTRIBUTE RedCreek-Tunneled-WINS-Server1 9 string
+ATTRIBUTE RedCreek-Tunneled-WINS-Server2 10 string
+ATTRIBUTE RedCreek-Tunneled-HostName 11 string
+ATTRIBUTE RedCreek-Tunneled-DomainName 12 string
+ATTRIBUTE RedCreek-Tunneled-Search-List 13 string
+
+END-VENDOR RedCreek
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 2865.
+# http://www.ietf.org/rfc/rfc2865.txt
+#
+# $Id$
+#
+ATTRIBUTE User-Name 1 string
+ATTRIBUTE User-Password 2 string encrypt=1
+ATTRIBUTE CHAP-Password 3 octets
+ATTRIBUTE NAS-IP-Address 4 ipaddr
+ATTRIBUTE NAS-Port 5 integer
+ATTRIBUTE Service-Type 6 integer
+ATTRIBUTE Framed-Protocol 7 integer
+ATTRIBUTE Framed-IP-Address 8 ipaddr
+ATTRIBUTE Framed-IP-Netmask 9 ipaddr
+ATTRIBUTE Framed-Routing 10 integer
+ATTRIBUTE Filter-Id 11 string
+ATTRIBUTE Framed-MTU 12 integer
+ATTRIBUTE Framed-Compression 13 integer
+ATTRIBUTE Login-IP-Host 14 ipaddr
+ATTRIBUTE Login-Service 15 integer
+ATTRIBUTE Login-TCP-Port 16 integer
+# Attribute 17 is undefined
+ATTRIBUTE Reply-Message 18 string
+ATTRIBUTE Callback-Number 19 string
+ATTRIBUTE Callback-Id 20 string
+# Attribute 21 is undefined
+ATTRIBUTE Framed-Route 22 string
+ATTRIBUTE Framed-IPX-Network 23 ipaddr
+ATTRIBUTE State 24 octets
+ATTRIBUTE Class 25 octets
+ATTRIBUTE Vendor-Specific 26 octets
+ATTRIBUTE Session-Timeout 27 integer
+ATTRIBUTE Idle-Timeout 28 integer
+ATTRIBUTE Termination-Action 29 integer
+ATTRIBUTE Called-Station-Id 30 string
+ATTRIBUTE Calling-Station-Id 31 string
+ATTRIBUTE NAS-Identifier 32 string
+ATTRIBUTE Proxy-State 33 octets
+ATTRIBUTE Login-LAT-Service 34 string
+ATTRIBUTE Login-LAT-Node 35 string
+ATTRIBUTE Login-LAT-Group 36 octets
+ATTRIBUTE Framed-AppleTalk-Link 37 integer
+ATTRIBUTE Framed-AppleTalk-Network 38 integer
+ATTRIBUTE Framed-AppleTalk-Zone 39 string
+
+ATTRIBUTE CHAP-Challenge 60 octets
+ATTRIBUTE NAS-Port-Type 61 integer
+ATTRIBUTE Port-Limit 62 integer
+ATTRIBUTE Login-LAT-Port 63 integer
+
+#
+# Integer Translations
+#
+
+# Service types
+
+VALUE Service-Type Login-User 1
+VALUE Service-Type Framed-User 2
+VALUE Service-Type Callback-Login-User 3
+VALUE Service-Type Callback-Framed-User 4
+VALUE Service-Type Outbound-User 5
+VALUE Service-Type Administrative-User 6
+VALUE Service-Type NAS-Prompt-User 7
+VALUE Service-Type Authenticate-Only 8
+VALUE Service-Type Callback-NAS-Prompt 9
+VALUE Service-Type Call-Check 10
+VALUE Service-Type Callback-Administrative 11
+
+# Framed Protocols
+
+VALUE Framed-Protocol PPP 1
+VALUE Framed-Protocol SLIP 2
+VALUE Framed-Protocol ARAP 3
+VALUE Framed-Protocol Gandalf-SLML 4
+VALUE Framed-Protocol Xylogics-IPX-SLIP 5
+VALUE Framed-Protocol X.75-Synchronous 6
+
+# Framed Routing Values
+
+VALUE Framed-Routing None 0
+VALUE Framed-Routing Broadcast 1
+VALUE Framed-Routing Listen 2
+VALUE Framed-Routing Broadcast-Listen 3
+
+# Framed Compression Types
+
+VALUE Framed-Compression None 0
+VALUE Framed-Compression Van-Jacobson-TCP-IP 1
+VALUE Framed-Compression IPX-Header-Compression 2
+VALUE Framed-Compression Stac-LZS 3
+
+# Login Services
+
+VALUE Login-Service Telnet 0
+VALUE Login-Service Rlogin 1
+VALUE Login-Service TCP-Clear 2
+VALUE Login-Service PortMaster 3
+VALUE Login-Service LAT 4
+VALUE Login-Service X25-PAD 5
+VALUE Login-Service X25-T3POS 6
+VALUE Login-Service TCP-Clear-Quiet 8
+
+# Login-TCP-Port (see /etc/services for more examples)
+
+VALUE Login-TCP-Port Telnet 23
+VALUE Login-TCP-Port Rlogin 513
+VALUE Login-TCP-Port Rsh 514
+
+# Termination Options
+
+VALUE Termination-Action Default 0
+VALUE Termination-Action RADIUS-Request 1
+
+# NAS Port Types
+
+VALUE NAS-Port-Type Async 0
+VALUE NAS-Port-Type Sync 1
+VALUE NAS-Port-Type ISDN 2
+VALUE NAS-Port-Type ISDN-V120 3
+VALUE NAS-Port-Type ISDN-V110 4
+VALUE NAS-Port-Type Virtual 5
+VALUE NAS-Port-Type PIAFS 6
+VALUE NAS-Port-Type HDLC-Clear-Channel 7
+VALUE NAS-Port-Type X.25 8
+VALUE NAS-Port-Type X.75 9
+VALUE NAS-Port-Type G.3-Fax 10
+VALUE NAS-Port-Type SDSL 11
+VALUE NAS-Port-Type ADSL-CAP 12
+VALUE NAS-Port-Type ADSL-DMT 13
+VALUE NAS-Port-Type IDSL 14
+VALUE NAS-Port-Type Ethernet 15
+VALUE NAS-Port-Type xDSL 16
+VALUE NAS-Port-Type Cable 17
+VALUE NAS-Port-Type Wireless-Other 18
+VALUE NAS-Port-Type Wireless-802.11 19
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 2866.
+# http://www.ietf.org/rfc/rfc2866.txt
+#
+# $Id$
+#
+ATTRIBUTE Acct-Status-Type 40 integer
+ATTRIBUTE Acct-Delay-Time 41 integer
+ATTRIBUTE Acct-Input-Octets 42 integer
+ATTRIBUTE Acct-Output-Octets 43 integer
+ATTRIBUTE Acct-Session-Id 44 string
+ATTRIBUTE Acct-Authentic 45 integer
+ATTRIBUTE Acct-Session-Time 46 integer
+ATTRIBUTE Acct-Input-Packets 47 integer
+ATTRIBUTE Acct-Output-Packets 48 integer
+ATTRIBUTE Acct-Terminate-Cause 49 integer
+ATTRIBUTE Acct-Multi-Session-Id 50 string
+ATTRIBUTE Acct-Link-Count 51 integer
+
+# Accounting Status Types
+
+VALUE Acct-Status-Type Start 1
+VALUE Acct-Status-Type Stop 2
+VALUE Acct-Status-Type Alive 3 # dup
+VALUE Acct-Status-Type Interim-Update 3
+VALUE Acct-Status-Type Accounting-On 7
+VALUE Acct-Status-Type Accounting-Off 8
+VALUE Acct-Status-Type Failed 15
+
+# Authentication Types
+
+VALUE Acct-Authentic RADIUS 1
+VALUE Acct-Authentic Local 2
+VALUE Acct-Authentic Remote 3
+VALUE Acct-Authentic Diameter 4
+
+# Acct Terminate Causes
+
+VALUE Acct-Terminate-Cause User-Request 1
+VALUE Acct-Terminate-Cause Lost-Carrier 2
+VALUE Acct-Terminate-Cause Lost-Service 3
+VALUE Acct-Terminate-Cause Idle-Timeout 4
+VALUE Acct-Terminate-Cause Session-Timeout 5
+VALUE Acct-Terminate-Cause Admin-Reset 6
+VALUE Acct-Terminate-Cause Admin-Reboot 7
+VALUE Acct-Terminate-Cause Port-Error 8
+VALUE Acct-Terminate-Cause NAS-Error 9
+VALUE Acct-Terminate-Cause NAS-Request 10
+VALUE Acct-Terminate-Cause NAS-Reboot 11
+VALUE Acct-Terminate-Cause Port-Unneeded 12
+VALUE Acct-Terminate-Cause Port-Preempted 13
+VALUE Acct-Terminate-Cause Port-Suspended 14
+VALUE Acct-Terminate-Cause Service-Unavailable 15
+VALUE Acct-Terminate-Cause Callback 16
+VALUE Acct-Terminate-Cause User-Error 17
+VALUE Acct-Terminate-Cause Host-Request 18
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 2867.
+# http://www.ietf.org/rfc/rfc2867.txt
+#
+# $Id$
+#
+ATTRIBUTE Acct-Tunnel-Connection 68 string
+ATTRIBUTE Acct-Tunnel-Packets-Lost 86 integer
+
+VALUE Acct-Status-Type Tunnel-Start 9
+VALUE Acct-Status-Type Tunnel-Stop 10
+VALUE Acct-Status-Type Tunnel-Reject 11
+VALUE Acct-Status-Type Tunnel-Link-Start 12
+VALUE Acct-Status-Type Tunnel-Link-Stop 13
+VALUE Acct-Status-Type Tunnel-Link-Reject 14
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 2868.
+# http://www.ietf.org/rfc/rfc2868.txt
+#
+# $Id$
+#
+ATTRIBUTE Tunnel-Type 64 integer has_tag
+ATTRIBUTE Tunnel-Medium-Type 65 integer has_tag
+ATTRIBUTE Tunnel-Client-Endpoint 66 string has_tag
+ATTRIBUTE Tunnel-Server-Endpoint 67 string has_tag
+
+ATTRIBUTE Tunnel-Password 69 string has_tag,encrypt=2
+
+ATTRIBUTE Tunnel-Private-Group-Id 81 string has_tag
+ATTRIBUTE Tunnel-Assignment-Id 82 string has_tag
+ATTRIBUTE Tunnel-Preference 83 integer has_tag
+
+ATTRIBUTE Tunnel-Client-Auth-Id 90 string has_tag
+ATTRIBUTE Tunnel-Server-Auth-Id 91 string has_tag
+
+# Tunnel Type
+
+VALUE Tunnel-Type PPTP 1
+VALUE Tunnel-Type L2F 2
+VALUE Tunnel-Type L2TP 3
+VALUE Tunnel-Type ATMP 4
+VALUE Tunnel-Type VTP 5
+VALUE Tunnel-Type AH 6
+VALUE Tunnel-Type IP 7
+VALUE Tunnel-Type MIN-IP 8
+VALUE Tunnel-Type ESP 9
+VALUE Tunnel-Type GRE 10
+VALUE Tunnel-Type DVS 11
+VALUE Tunnel-Type IP-in-IP 12
+
+# Tunnel Medium Type
+
+VALUE Tunnel-Medium-Type IP 1
+VALUE Tunnel-Medium-Type X25 2
+VALUE Tunnel-Medium-Type ATM 3
+VALUE Tunnel-Medium-Type Frame-Relay 4
+VALUE Tunnel-Medium-Type BBN-1822 5
+VALUE Tunnel-Medium-Type IEEE-802 6
+VALUE Tunnel-Medium-Type E.163 7
+VALUE Tunnel-Medium-Type E.164 8
+VALUE Tunnel-Medium-Type F.69 9
+VALUE Tunnel-Medium-Type X.121 10
+VALUE Tunnel-Medium-Type IPX 11
+VALUE Tunnel-Medium-Type Appletalk 12
+VALUE Tunnel-Medium-Type DecNet-IV 13
+VALUE Tunnel-Medium-Type Banyan-Vines 14
+VALUE Tunnel-Medium-Type E.164-NSAP 15
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 2869.
+# http://www.ietf.org/rfc/rfc2869.txt
+#
+# $Id$
+#
+ATTRIBUTE Acct-Input-Gigawords 52 integer
+ATTRIBUTE Acct-Output-Gigawords 53 integer
+
+ATTRIBUTE Event-Timestamp 55 date
+
+ATTRIBUTE ARAP-Password 70 octets # 16 octets of data
+ATTRIBUTE ARAP-Features 71 octets # 14 octets of data
+ATTRIBUTE ARAP-Zone-Access 72 integer
+ATTRIBUTE ARAP-Security 73 integer
+ATTRIBUTE ARAP-Security-Data 74 string
+ATTRIBUTE Password-Retry 75 integer
+ATTRIBUTE Prompt 76 integer
+ATTRIBUTE Connect-Info 77 string
+ATTRIBUTE Configuration-Token 78 string
+ATTRIBUTE EAP-Message 79 octets
+ATTRIBUTE Message-Authenticator 80 octets
+
+ATTRIBUTE ARAP-Challenge-Response 84 octets # 8 octets of data
+ATTRIBUTE Acct-Interim-Interval 85 integer
+# 86: RFC 2867
+ATTRIBUTE NAS-Port-Id 87 string
+ATTRIBUTE Framed-Pool 88 string
+
+# ARAP Zone Access
+
+VALUE ARAP-Zone-Access Default-Zone 1
+VALUE ARAP-Zone-Access Zone-Filter-Inclusive 2
+VALUE ARAP-Zone-Access Zone-Filter-Exclusive 4
+
+# Prompt
+VALUE Prompt No-Echo 0
+VALUE Prompt Echo 1
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 3162.
+# http://www.ietf.org/rfc/rfc3162.txt
+#
+# $Id$
+#
+ATTRIBUTE NAS-IPv6-Address 95 ipv6addr
+ATTRIBUTE Framed-Interface-Id 96 ifid
+ATTRIBUTE Framed-IPv6-Prefix 97 ipv6prefix
+ATTRIBUTE Login-IPv6-Host 98 ipv6addr
+ATTRIBUTE Framed-IPv6-Route 99 string
+ATTRIBUTE Framed-IPv6-Pool 100 string
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 3576.
+# http://www.ietf.org/rfc/rfc3576.txt
+#
+# $Id$
+#
+ATTRIBUTE Error-Cause 101 integer
+
+# Service Types
+
+VALUE Service-Type Authorize-Only 17
+
+# Error causes
+
+VALUE Error-Cause Residual-Context-Removed 201
+VALUE Error-Cause Invalid-EAP-Packet 202
+VALUE Error-Cause Unsupported-Attribute 401
+VALUE Error-Cause Missing-Attribute 402
+VALUE Error-Cause NAS-Identification-Mismatch 403
+VALUE Error-Cause Invalid-Request 404
+VALUE Error-Cause Unsupported-Service 405
+VALUE Error-Cause Unsupported-Extension 406
+VALUE Error-Cause Administratively-Prohibited 501
+VALUE Error-Cause Proxy-Request-Not-Routable 502
+VALUE Error-Cause Session-Context-Not-Found 503
+VALUE Error-Cause Session-Context-Not-Removable 504
+VALUE Error-Cause Proxy-Processing-Error 505
+VALUE Error-Cause Resources-Unavailable 506
+VALUE Error-Cause Request-Initiated 507
--- /dev/null
+# -*- text -*-
+#
+# Attributes and values defined in RFC 3580.
+# http://www.ietf.org/rfc/rfc3580.txt
+#
+# $Id$
+#
+VALUE Acct-Terminate-Cause Supplicant-Restart 19
+VALUE Acct-Terminate-Cause Reauthentication-Failure 20
+VALUE Acct-Terminate-Cause Port-Reinit 21
+VALUE Acct-Terminate-Cause Port-Disabled 22
+
+VALUE NAS-Port-Type Token-Ring 20
+VALUE NAS-Port-Type FDDI 21
+
+VALUE Tunnel-Type VLAN 13
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Roaring Penguin attributes
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Roaring-Penguin 10055
+
+BEGIN-VENDOR Roaring-Penguin
+
+ATTRIBUTE RP-Upstream-Speed-Limit 1 integer
+ATTRIBUTE RP-Downstream-Speed-Limit 2 integer
+
+END-VENDOR Roaring-Penguin
+# -*- text -*-
#
# dictionary.shasta
#
# Nortel Shasta VSAs
# Andre Gustavo de C. Albuquerque <gustavoa@nortelnetworks.com>
-#
+#
-VENDOR Shasta 3199
+VENDOR Shasta 3199
#
# Standard attribute
#
-ATTRIBUTE Shasta-User-Privilege 1 integer Shasta
-ATTRIBUTE Shasta-Service-Profile 2 string Shasta
-ATTRIBUTE Shasta-VPN-Name 3 string Shasta
+BEGIN-VENDOR Shasta
+
+ATTRIBUTE Shasta-User-Privilege 1 integer
+ATTRIBUTE Shasta-Service-Profile 2 string
+ATTRIBUTE Shasta-VPN-Name 3 string
+
+VALUE Shasta-User-Privilege User 1
+VALUE Shasta-User-Privilege Super-User 2
+VALUE Shasta-User-Privilege SSuper-User 3
-VALUE Shasta-User-Privilege User 1
-VALUE Shasta-User-Privilege Super-User 2
-VALUE Shasta-User-Privilege SSuper-User 3
+END-VENDOR Shasta
+# -*- text -*-
#
# Shiva dictionary.
#
# $Id$
#
-VENDOR Shiva 166
+VENDOR Shiva 166
# Shiva Extensions
#
#ATTRIBUTE Shiva-User-Attributes 51 string
-ATTRIBUTE Shiva-User-Attributes 1 string Shiva
-ATTRIBUTE Shiva-Called-Number 90 string Shiva
-ATTRIBUTE Shiva-Calling-Number 91 string Shiva
-ATTRIBUTE Shiva-Customer-Id 92 string Shiva
-ATTRIBUTE Shiva-Type-Of-Service 93 integer Shiva
-ATTRIBUTE Shiva-Link-Speed 94 integer Shiva
-ATTRIBUTE Shiva-Links-In-Bundle 95 integer Shiva
-ATTRIBUTE Shiva-Compression-Type 96 integer Shiva
-ATTRIBUTE Shiva-Link-Protocol 97 integer Shiva
-ATTRIBUTE Shiva-Network-Protocols 98 integer Shiva
-ATTRIBUTE Shiva-Session-Id 99 integer Shiva
-ATTRIBUTE Shiva-Disconnect-Reason 100 integer Shiva
-ATTRIBUTE Shiva-Acct-Serv-Switch 101 ipaddr Shiva
-ATTRIBUTE Shiva-Event-Flags 102 integer Shiva
-ATTRIBUTE Shiva-Function 103 integer Shiva
-ATTRIBUTE Shiva-Connect-Reason 104 integer Shiva
+BEGIN-VENDOR Shiva
+
+ATTRIBUTE Shiva-User-Attributes 1 string
+ATTRIBUTE Shiva-Compression 30 integer
+ATTRIBUTE Shiva-Dialback-Delay 31 integer
+ATTRIBUTE Shiva-Call-Durn-Trap 32 integer
+ATTRIBUTE Shiva-Bandwidth-Trap 33 integer
+ATTRIBUTE Shiva-Minimum-Call 34 integer
+ATTRIBUTE Shiva-Default-Host 35 string
+ATTRIBUTE Shiva-Menu-Name 36 string
+ATTRIBUTE Shiva-User-Flags 37 string
+ATTRIBUTE Shiva-Termtype 38 string
+ATTRIBUTE Shiva-Break-Key 39 string
+ATTRIBUTE Shiva-Fwd-Key 40 string
+ATTRIBUTE Shiva-Bak-Key 41 string
+ATTRIBUTE Shiva-Dial-Timeout 42 integer
+ATTRIBUTE Shiva-LAT-Port 43 string
+ATTRIBUTE Shiva-Max-VCs 44 integer
+ATTRIBUTE Shiva-DHCP-Leasetime 45 integer
+ATTRIBUTE Shiva-LAT-Groups 46 string
+ATTRIBUTE Shiva-RTC-Timestamp 60 integer
+ATTRIBUTE Shiva-Circuit-Type 61 integer
+ATTRIBUTE Shiva-Called-Number 90 string
+ATTRIBUTE Shiva-Calling-Number 91 string
+ATTRIBUTE Shiva-Customer-Id 92 string
+ATTRIBUTE Shiva-Type-Of-Service 93 integer
+ATTRIBUTE Shiva-Link-Speed 94 integer
+ATTRIBUTE Shiva-Links-In-Bundle 95 integer
+ATTRIBUTE Shiva-Compression-Type 96 integer
+ATTRIBUTE Shiva-Link-Protocol 97 integer
+ATTRIBUTE Shiva-Network-Protocols 98 integer
+ATTRIBUTE Shiva-Session-Id 99 integer
+ATTRIBUTE Shiva-Disconnect-Reason 100 integer
+ATTRIBUTE Shiva-Acct-Serv-Switch 101 ipaddr
+ATTRIBUTE Shiva-Event-Flags 102 integer
+ATTRIBUTE Shiva-Function 103 integer
+ATTRIBUTE Shiva-Connect-Reason 104 integer
+
+VALUE Shiva-Compression None 0
+VALUE Shiva-Compression Negotiate 1
+VALUE Shiva-Compression Spider 2
+VALUE Shiva-Compression Predictor 3
+VALUE Shiva-Compression STAC 4
+
+VALUE Shiva-Circuit-Type Primary 1
+VALUE Shiva-Circuit-Type Secondary-Backup 2
+VALUE Shiva-Circuit-Type Secondary-Augment 3
+VALUE Shiva-Circuit-Type Secondary-Switch 4
+VALUE Shiva-Circuit-Type Listener 5
+VALUE Shiva-Circuit-Type RADIUS 6
# Shiva Type Of Service Values
-VALUE Shiva-Type-Of-Service Analog 1
-VALUE Shiva-Type-Of-Service Digitized-Analog 2
-VALUE Shiva-Type-Of-Service Digital 3
-VALUE Shiva-Type-Of-Service Digital-V110 4
-VALUE Shiva-Type-Of-Service Digital-V120 5
-VALUE Shiva-Type-Of-Service Digital-Leased-Line 6
+VALUE Shiva-Type-Of-Service Analog 1
+VALUE Shiva-Type-Of-Service Digitized-Analog 2
+VALUE Shiva-Type-Of-Service Digital 3
+VALUE Shiva-Type-Of-Service Digital-V110 4
+VALUE Shiva-Type-Of-Service Digital-V120 5
+VALUE Shiva-Type-Of-Service Digital-Leased-Line 6
# Shiva Link Protocol Values
-VALUE Shiva-Link-Protocol HDLC 1
-VALUE Shiva-Link-Protocol ARAV1 2
-VALUE Shiva-Link-Protocol ARAV2 3
-VALUE Shiva-Link-Protocol SHELL 4
-VALUE Shiva-Link-Protocol AALAP 5
-VALUE Shiva-Link-Protocol SLIP 6
+VALUE Shiva-Link-Protocol HDLC 1
+VALUE Shiva-Link-Protocol ARAV1 2
+VALUE Shiva-Link-Protocol ARAV2 3
+VALUE Shiva-Link-Protocol SHELL 4
+VALUE Shiva-Link-Protocol AALAP 5
+VALUE Shiva-Link-Protocol SLIP 6
# Shiva Connect Reason Values
-VALUE Shiva-Connect-Reason Remote 1
-VALUE Shiva-Connect-Reason Dialback 2
-VALUE Shiva-Connect-Reason Virtual-Connection 3
-VALUE Shiva-Connect-Reason Bandwidth-On-Demand 4
+VALUE Shiva-Connect-Reason Remote 1
+VALUE Shiva-Connect-Reason Dialback 2
+VALUE Shiva-Connect-Reason Virtual-Connection 3
+VALUE Shiva-Connect-Reason Bandwidth-On-Demand 4
# Shiva Disconnect Reason Values
-VALUE Shiva-Disconnect-Reason Remote 1
-VALUE Shiva-Disconnect-Reason Error 2
-VALUE Shiva-Disconnect-Reason Idle-Timeout 3
-VALUE Shiva-Disconnect-Reason Session-Timeout 4
-VALUE Shiva-Disconnect-Reason Admin-Disconnect 5
-VALUE Shiva-Disconnect-Reason Dialback 6
-VALUE Shiva-Disconnect-Reason Virtual-Connection 7
-VALUE Shiva-Disconnect-Reason Bandwidth-On-Demand 8
-VALUE Shiva-Disconnect-Reason Failed-Authentication 9
-VALUE Shiva-Disconnect-Reason Preempted 10
-VALUE Shiva-Disconnect-Reason Blocked 11
-VALUE Shiva-Disconnect-Reason Tariff-Management 12
-VALUE Shiva-Disconnect-Reason Backup 13
+VALUE Shiva-Disconnect-Reason Remote 1
+VALUE Shiva-Disconnect-Reason Error 2
+VALUE Shiva-Disconnect-Reason Idle-Timeout 3
+VALUE Shiva-Disconnect-Reason Session-Timeout 4
+VALUE Shiva-Disconnect-Reason Admin-Disconnect 5
+VALUE Shiva-Disconnect-Reason Dialback 6
+VALUE Shiva-Disconnect-Reason Virtual-Connection 7
+VALUE Shiva-Disconnect-Reason Bandwidth-On-Demand 8
+VALUE Shiva-Disconnect-Reason Failed-Authentication 9
+VALUE Shiva-Disconnect-Reason Preempted 10
+VALUE Shiva-Disconnect-Reason Blocked 11
+VALUE Shiva-Disconnect-Reason Tariff-Management 12
+VALUE Shiva-Disconnect-Reason Backup 13
# Shiva Function Values
-VALUE Shiva-Function Unknown 0
-VALUE Shiva-Function Dialin 1
-VALUE Shiva-Function Dialout 2
-VALUE Shiva-Function Lan-To-Lan 3
+VALUE Shiva-Function Unknown 0
+VALUE Shiva-Function Dialin 1
+VALUE Shiva-Function Dialout 2
+VALUE Shiva-Function Lan-To-Lan 3
+END-VENDOR Shiva
+# -*- text -*-
#
# Sonicwall Firewall dictionary
#
# $Id$
#
-VENDOR SonicWall 8741
+VENDOR SonicWall 8741
# Backwards compatibility.
-ATTRIBUTE SS3-Firewall-User-Privilege 1 integer SonicWall
+BEGIN-VENDOR SonicWall
+
+ATTRIBUTE SS3-Firewall-User-Privilege 1 integer
# New names.
-ATTRIBUTE SonicWall-User-Privilege 1 integer SonicWall
-VALUE SonicWall-User-Privilege Remote-Access 1 # deprecated
+ATTRIBUTE SonicWall-User-Privilege 1 integer
+VALUE SonicWall-User-Privilege Remote-Access 1 # deprecated
VALUE SonicWall-User-Privilege Bypass-Filters 2
VALUE SonicWall-User-Privilege VPN-Client-Access 3 # standard
VALUE SonicWall-User-Privilege Access-To-VPN 4 # standard
# "RA" for "Remote-Access" is now deprecated.
# ATTRIBUTE SonicWall-User-Privileges 2 string SonicWall
-
# Multiple of these can be set for a user, each specifying the name of a
# user group to which that user has membership. Note that this can
# alternatively be achieved by use of the Filter-Id attribute.
# This is applicable only on a SonicWall firewall running enhanced firmware.
#
-ATTRIBUTE SonicWall-User-Group 3 string SonicWall
+ATTRIBUTE SonicWall-User-Group 3 string
# This attribute is to use in place of SonicWall-User-Group with RADIUS
# servers that allow only one instance of a Vendor-Specific attribute to be
# This is applicable only on a SonicWall firewall running enhanced firmware.
#
# ATTRIBUTE SonicWall-User-Groups 4 string SonicWall.
+
+END-VENDOR SonicWall
+# -*- text -*-
##############################################################################
#
# SpringTide VSAs
#
##############################################################################
-VENDOR SpringTide 3551
+VENDOR SpringTide 3551
-ATTRIBUTE ST-Acct-VC-Connection-Id 1 string SpringTide
-ATTRIBUTE ST-Service-Name 2 string SpringTide
-ATTRIBUTE ST-Service-Domain 3 integer SpringTide
-ATTRIBUTE ST-Policy-Name 4 string SpringTide
-ATTRIBUTE ST-Primary-DNS-Server 5 ipaddr SpringTide
-ATTRIBUTE ST-Secondary-DNS-Server 6 ipaddr SpringTide
-ATTRIBUTE ST-Primary-NBNS-Server 7 ipaddr SpringTide
-ATTRIBUTE ST-Secondary-NBNS-Server 8 ipaddr SpringTide
+BEGIN-VENDOR SpringTide
+
+ATTRIBUTE ST-Acct-VC-Connection-Id 1 string
+ATTRIBUTE ST-Service-Name 2 string
+ATTRIBUTE ST-Service-Domain 3 integer
+ATTRIBUTE ST-Policy-Name 4 string
+ATTRIBUTE ST-Primary-DNS-Server 5 ipaddr
+ATTRIBUTE ST-Secondary-DNS-Server 6 ipaddr
+ATTRIBUTE ST-Primary-NBNS-Server 7 ipaddr
+ATTRIBUTE ST-Secondary-NBNS-Server 8 ipaddr
+ATTRIBUTE ST-Physical-Port 9 integer
+ATTRIBUTE ST-Physical-Slot 10 integer
+ATTRIBUTE ST-Virtual-Path-ID 11 integer
+ATTRIBUTE ST-Virtual-Circuit-ID 12 integer
+ATTRIBUTE ST-Realm-Name 13 string
+ATTRIBUTE ST-IPSec-Pfs-Group 14 integer
+ATTRIBUTE ST-IPSec-Client-Firewall 15 integer
+ATTRIBUTE ST-IPSec-Client-Subnet 16 string
+
+END-VENDOR SpringTide
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Starent dictionary
+# http://www.starentnetworks.com/
+#
+# These appear to be 16-bit VSA types, with 16-bit lengths.
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Starent 8164 format=2,2
+
+BEGIN-VENDOR Starent
+
+ATTRIBUTE SN-VPN-ID 1 integer
+ATTRIBUTE SN-VPN-Name 2 string
+ATTRIBUTE SN-Disconnect-Reason 3 integer
+ATTRIBUTE SN-PPP-Progress-Code 4 integer
+ATTRIBUTE SN-Primary-DNS-Server 5 ipaddr
+ATTRIBUTE SN-Secondary-DNS-Server 6 ipaddr
+ATTRIBUTE SN-Re-CHAP-Interval 7 integer
+ATTRIBUTE SN-IP-Pool-Name 8 string
+ATTRIBUTE SN-PPP-Data-Compression 9 integer
+ATTRIBUTE SN-IP-Filter-In 10 string
+ATTRIBUTE SN-IP-Filter-Out 11 string
+ATTRIBUTE SN-Local-IP-Address 13 ipaddr
+ATTRIBUTE SN-IP-Source-Validation 14 integer
+ATTRIBUTE SN-PPP-Outbound-Password 15 string
+ATTRIBUTE SN-PPP-Keepalive 16 integer
+ATTRIBUTE SN-IP-In-ACL 17 string
+ATTRIBUTE SN-IP-Out-ACL 18 string
+ATTRIBUTE SN-PPP-Data-Compression-Mode 19 integer
+ATTRIBUTE SN-Subscriber-Permission 20 integer
+ATTRIBUTE SN-Admin-Permission 21 integer
+ATTRIBUTE SN-Simultaneous-SIP-MIP 22 integer
+ATTRIBUTE SN-Min-Compress-Size 23 integer
+ATTRIBUTE SNA-PPP-Unfr-data-In-Oct 200 integer
+ATTRIBUTE SNA-PPP-Unfr-data-Out-Oct 201 integer
+ATTRIBUTE SNA-PPP-Ctrl-Input-Octets 1001 integer
+ATTRIBUTE SNA-PPP-Ctrl-Output-Octets 1002 integer
+ATTRIBUTE SNA-PPP-Ctrl-Input-Packets 1003 integer
+ATTRIBUTE SNA-PPP-Ctrl-Output-Packets 1004 integer
+ATTRIBUTE SNA-PPP-Framed-Input-Octets 1005 integer
+ATTRIBUTE SNA-PPP-Framed-Output-Octets 1006 integer
+ATTRIBUTE SNA-PPP-Discards-Input 1007 integer
+ATTRIBUTE SNA-PPP-Discards-Output 1008 integer
+ATTRIBUTE SNA-PPP-Errors-Input 1009 integer
+ATTRIBUTE SNA-PPP-Errors-Output 1010 integer
+ATTRIBUTE SNA-PPP-Bad-Addr 1011 integer
+ATTRIBUTE SNA-PPP-Bad-Ctrl 1012 integer
+ATTRIBUTE SNA-PPP-Packet-Too-Long 1013 integer
+ATTRIBUTE SNA-PPP-Bad-FCS 1014 integer
+ATTRIBUTE SNA-PPP-Echo-Req-Input 1015 integer
+ATTRIBUTE SNA-PPP-Echo-Req-Output 1016 integer
+ATTRIBUTE SNA-PPP-Echo-Rsp-Input 1017 integer
+ATTRIBUTE SNA-PPP-Echo-Rsp-Output 1018 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Total 1019 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Acc-Reg 1020 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Acc-Dereg 1021 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Msg-Auth-Fail 1022 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Mis-ID 1023 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-Badly-Formed 1024 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-VID-Unsupported 1025 integer
+ATTRIBUTE SNA-RPRRQ-Rcvd-T-Bit-Not-Set 1026 integer
+ATTRIBUTE SNA-RPRAK-Rcvd-Total 1027 integer
+ATTRIBUTE SNA-RPRAK-Rcvd-Acc-Ack 1028 integer
+ATTRIBUTE SNA-RPRAK-Rcvd-Msg-Auth-Fail 1029 integer
+ATTRIBUTE SNA-RPRAK-Rcvd-Mis-ID 1030 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Total 1031 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Acc-Reg 1032 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Acc-Dereg 1033 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Bad-Req 1034 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Denied 1035 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Mis-ID 1036 integer
+ATTRIBUTE SNA-RP-Reg-Reply-Sent-Send-Err 1037 integer
+ATTRIBUTE SNA-RP-Reg-Upd-Sent 1038 integer
+ATTRIBUTE SNA-RP-Reg-Upd-Re-Sent 1039 integer
+ATTRIBUTE SNA-RP-Reg-Upd-Send-Err 1040 integer
+
+VALUE SN-Disconnect-Reason Not-Defined 0
+VALUE SN-Disconnect-Reason Admin-Disconnect 1
+VALUE SN-Disconnect-Reason Remote-Disconnect 2
+VALUE SN-Disconnect-Reason Local-Disconnect 3
+VALUE SN-Disconnect-Reason Disc-No-Resource 4
+VALUE SN-Disconnect-Reason Disc-Excd-Service-Limit 5
+VALUE SN-Disconnect-Reason PPP-LCP-Neg-Failed 6
+VALUE SN-Disconnect-Reason PPP-LCP-No-Response 7
+VALUE SN-Disconnect-Reason PPP-LCP-Loopback 8
+VALUE SN-Disconnect-Reason PPP-LCP-Max-Retry 9
+VALUE SN-Disconnect-Reason PPP-Echo-Failed 10
+VALUE SN-Disconnect-Reason PPP-Auth-Failed 11
+VALUE SN-Disconnect-Reason PPP-Auth-Failed-No-AAA-Resp 12
+VALUE SN-Disconnect-Reason PPP-Auth-No-Response 13
+VALUE SN-Disconnect-Reason PPP-Auth-Max-Retry 14
+VALUE SN-Disconnect-Reason Invalid-AAA-Attr 15
+VALUE SN-Disconnect-Reason Failed-User-Filter 16
+VALUE SN-Disconnect-Reason Failed-Provide-Service 17
+VALUE SN-Disconnect-Reason Invalid-IP-Address-AAA 18
+VALUE SN-Disconnect-Reason Invalid-IP-Pool-AAA 19
+VALUE SN-Disconnect-Reason PPP-IPCP-Neg-Failed 20
+VALUE SN-Disconnect-Reason PPP-IPCP-No-Response 21
+VALUE SN-Disconnect-Reason PPP-IPCP-Max-Retry 22
+VALUE SN-Disconnect-Reason PPP-No-Rem-IP-Address 23
+VALUE SN-Disconnect-Reason Inactivity-Timeout 24
+VALUE SN-Disconnect-Reason Session-Timeout 25
+VALUE SN-Disconnect-Reason Max-Data-Excd 26
+VALUE SN-Disconnect-Reason Invalid-IP-Source-Address 27
+VALUE SN-Disconnect-Reason MSID-Auth-Failed 28
+VALUE SN-Disconnect-Reason MSID-Auth-Fauiled-No-AAA-Resp 29
+VALUE SN-Disconnect-Reason A11-Max-Retry 30
+VALUE SN-Disconnect-Reason A11-Lifetime-Expired 31
+VALUE SN-Disconnect-Reason A11-Message-Integrity-Failure 32
+VALUE SN-Disconnect-Reason PPP-lcp-remote-disc 33
+VALUE SN-Disconnect-Reason Session-setup-timeout 34
+VALUE SN-Disconnect-Reason PPP-keepalive-failure 35
+VALUE SN-Disconnect-Reason Flow-add-failed 36
+VALUE SN-Disconnect-Reason Call-type-detection-failed 37
+VALUE SN-Disconnect-Reason Wrong-ipcp-params 38
+VALUE SN-Disconnect-Reason MIP-remote-dereg 39
+VALUE SN-Disconnect-Reason MIP-lifetime-expiry 40
+VALUE SN-Disconnect-Reason MIP-proto-error 41
+VALUE SN-Disconnect-Reason MIP-auth-failure 42
+VALUE SN-Disconnect-Reason MIP-reg-timeout 43
+VALUE SN-Disconnect-Reason Invalid-dest-context 44
+VALUE SN-Disconnect-Reason Source-context-removed 45
+VALUE SN-Disconnect-Reason Destination-context-removed 46
+VALUE SN-Disconnect-Reason Req-service-addr-unavailable 47
+VALUE SN-Disconnect-Reason Demux-mgr-failed 48
+VALUE SN-Disconnect-Reason Internal-error 49
+
+VALUE SN-PPP-Progress-Code Not-Defined 0
+VALUE SN-PPP-Progress-Code Call-Lcp-Down 1
+VALUE SN-PPP-Progress-Code Call-Disconnecting 2
+VALUE SN-PPP-Progress-Code Call-Ppp-Renegotiating 3
+VALUE SN-PPP-Progress-Code Call-Arrived 11
+VALUE SN-PPP-Progress-Code Call-Lcp-Up 12
+VALUE SN-PPP-Progress-Code Call-Authenticating 13
+VALUE SN-PPP-Progress-Code Call-Authenticated 14
+VALUE SN-PPP-Progress-Code Call-Ipcp-Up 15
+VALUE SN-PPP-Progress-Code Call-Simple-IP-Connected 16
+VALUE SN-PPP-Progress-Code Call-Mobile-IP-Connected 17
+
+VALUE SN-PPP-Data-Compression None 0
+VALUE SN-PPP-Data-Compression Stac-LZS 1
+VALUE SN-PPP-Data-Compression MPPC 2
+VALUE SN-PPP-Data-Compression MPCC-Stac-LZS 3
+VALUE SN-PPP-Data-Compression Deflate 4
+VALUE SN-PPP-Data-Compression Deflate-Stac-LZS 5
+VALUE SN-PPP-Data-Compression Deflate-MPCC 6
+VALUE SN-PPP-Data-Compression Deflate-MPCC-Stac-LZS 7
+
+VALUE SN-IP-Source-Validation No 0
+VALUE SN-IP-Source-Validation Yes 1
+
+VALUE SN-Subscriber-Permission None 0
+VALUE SN-Subscriber-Permission Simple-IP 1
+VALUE SN-Subscriber-Permission Mobile-IP 2
+VALUE SN-Subscriber-Permission Simple-IP-Mobile-IP 3
+VALUE SN-Subscriber-Permission HA-Mobile-IP 4
+VALUE SN-Subscriber-Permission Simple-IP-HA-Mobile-IP 5
+VALUE SN-Subscriber-Permission Mobile-IP-HA-Mobile-IP 6
+VALUE SN-Subscriber-Permission All 7
+
+VALUE SN-Admin-Permission None 0
+VALUE SN-Admin-Permission CLI 1
+VALUE SN-Admin-Permission FTP 2
+
+VALUE SN-Simultaneous-SIP-MIP Disabled 0
+VALUE SN-Simultaneous-SIP-MIP Enabled 1
+
+VALUE SN-PPP-Data-Compression-Mode Normal 0
+VALUE SN-PPP-Data-Compression-Mode Stateless 1
+
+END-VENDOR Starent
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# T-Systems-Nova
+#
+# $Id$
+#
+##############################################################################
+VENDOR T-Systems-Nova 16787
+
+BEGIN-VENDOR T-Systems-Nova
+
+ATTRIBUTE T-Systems-Nova-Location-ID 1 string
+ATTRIBUTE T-Systems-Nova-Location-Name 2 string
+ATTRIBUTE T-Systems-Nova-Logoff-URL 3 string
+ATTRIBUTE T-Systems-Nova-Redirection-URL 4 string
+ATTRIBUTE T-Systems-Nova-Bandwidth-Min-Up 5 integer
+ATTRIBUTE T-Systems-Nova-Bandwidth-Min-Down 6 integer
+ATTRIBUTE T-Systems-Nova-Bandwidth-Max-Up 7 integer
+ATTRIBUTE T-Systems-Nova-Bandwidth-Max-Down 8 integer
+ATTRIBUTE T-Systems-Nova-Session-Terminate-Time 9 integer
+
+#ATTRIBUTE T-Systems-Nova-Session-Terminate-End-Of-Day 10 integer
+ATTRIBUTE T-Systems-Nova-Session-Terminate-EoD 10 integer
+
+ATTRIBUTE T-Systems-Nova-Billing-Class-Of-Service 11 string
+ATTRIBUTE T-Systems-Nova-Service-Name 12 string
+ATTRIBUTE T-Systems-Nova-Price-Of-Service 13 integer
+ATTRIBUTE T-Systems-Nova-Visiting-Provider-Code 14 string
+ATTRIBUTE T-Systems-Nova-UnknownAVP 15 string
+
+END-VENDOR T-Systems-Nova
+# -*- text -*-
#
# Telebit dictionary
# $Id$
#
-VENDOR Telebit 117
+VENDOR Telebit 117
-ATTRIBUTE Telebit-Login-Command 1 string Telebit
-ATTRIBUTE Telebit-Port-Name 2 string Telebit
-ATTRIBUTE Telebit-Activate-Command 3 string Telebit
-ATTRIBUTE Telebit-Accounting-Info 4 string Telebit
+BEGIN-VENDOR Telebit
+
+ATTRIBUTE Telebit-Login-Command 1 string
+ATTRIBUTE Telebit-Port-Name 2 string
+ATTRIBUTE Telebit-Activate-Command 3 string
+ATTRIBUTE Telebit-Accounting-Info 4 string
+
+END-VENDOR Telebit
+# -*- text -*-
#
# dictionary.trapeze
#
# $Id$
#
#
-VENDOR Trapeze 14525
+VENDOR Trapeze 14525
# Attributes for MSS 1.1 and later
-ATTRIBUTE Trapeze-VLAN-Name 1 string Trapeze
-ATTRIBUTE Trapeze-Mobility-Profile 2 string Trapeze
-ATTRIBUTE Trapeze-Encryption-Type 3 string Trapeze
-ATTRIBUTE Trapeze-Time-Of-Day 4 string Trapeze
+BEGIN-VENDOR Trapeze
+
+ATTRIBUTE Trapeze-VLAN-Name 1 string
+ATTRIBUTE Trapeze-Mobility-Profile 2 string
+ATTRIBUTE Trapeze-Encryption-Type 3 string
+ATTRIBUTE Trapeze-Time-Of-Day 4 string
# New attributes for MSS 3.0 and later
-ATTRIBUTE Trapeze-SSID 5 string Trapeze
-ATTRIBUTE Trapeze-End-Date 6 string Trapeze
-ATTRIBUTE Trapeze-Start-Date 7 string Trapeze
-ATTRIBUTE Trapeze-URL 8 string Trapeze
+ATTRIBUTE Trapeze-SSID 5 string
+ATTRIBUTE Trapeze-End-Date 6 string
+ATTRIBUTE Trapeze-Start-Date 7 string
+ATTRIBUTE Trapeze-URL 8 string
+
+END-VENDOR Trapeze
+# -*- text -*-
#
# Allegedly for ProFTPd.
#
# $Id$
#
-VENDOR Unix 4
+VENDOR Unix 4
BEGIN-VENDOR Unix
-ATTRIBUTE Unix-FTP-UID 10 integer
-ATTRIBUTE Unix-FTP-GID 11 integer
-ATTRIBUTE Unix-FTP-Home 12 string
-ATTRIBUTE Unix-FTP-Shell 13 string
-ATTRIBUTE Unix-FTP-Group-Names 14 string
-ATTRIBUTE Unix-FTP-Group-Ids 15 string
+ATTRIBUTE Unix-FTP-UID 10 integer
+ATTRIBUTE Unix-FTP-GID 11 integer
+ATTRIBUTE Unix-FTP-Home 12 string
+ATTRIBUTE Unix-FTP-Shell 13 string
+ATTRIBUTE Unix-FTP-Group-Names 14 string
+ATTRIBUTE Unix-FTP-Group-Ids 15 string
END-VENDOR Unix
+# -*- text -*-
#
# dictionary.usr USR Robotics dictionary.
#
#
# Prompt value should be 1 for echo, 0 for no echo, default 1.
#ATTRIBUTE Prompt 64 integer
-ATTRIBUTE Multi-Link-Flag 126 integer
-ATTRIBUTE Char-Noecho 250 integer
+ATTRIBUTE Multi-Link-Flag 126 integer
+ATTRIBUTE Char-Noecho 250 integer
#
# USR specific Integer Translations
#
-VALUE Termination-Action Manage-Resources 2
+VALUE Termination-Action Manage-Resources 2
-VALUE Acct-Status-Type Modem-Start 4
-VALUE Acct-Status-Type Modem-Stop 5
-VALUE Acct-Status-Type Cancel 6
+VALUE Acct-Status-Type Modem-Start 4
+VALUE Acct-Status-Type Modem-Stop 5
+VALUE Acct-Status-Type Cancel 6
-VALUE Multi-Link-Flag True 1
-VALUE Multi-Link-Flag False 0
+VALUE Multi-Link-Flag True 1
+VALUE Multi-Link-Flag False 0
# USR specific Authentication Types
# normal vendor-specific format would work just as well.
#
#
-VENDOR USR 429
+VENDOR USR 429 format=4,0
BEGIN-VENDOR USR
ATTRIBUTE USR-Last-Number-Dialed-Out 0x0066 string
ATTRIBUTE USR-Last-Number-Dialed-In-DNIS 0x00E8 string
ATTRIBUTE USR-Last-Callers-Number-ANI 0x00E9 string
-ATTRIBUTE USR-Channel 0xBF38 integer
+ATTRIBUTE USR-Channel 0xBF38 integer
ATTRIBUTE USR-Event-Id 0xBFBE integer
ATTRIBUTE USR-Event-Date-Time 0xBF2F date
ATTRIBUTE USR-Call-Start-Date-Time 0xBFF7 date
# 0xBE5D-0xBE63 sent with Event-Id 79
ATTRIBUTE USR-Channel-Connected-To 0xBE5D integer
-ATTRIBUTE USR-Slot-Connected-To 0xBE5E integer
+ATTRIBUTE USR-Slot-Connected-To 0xBE5E integer
ATTRIBUTE USR-Device-Connected-To 0xBE5F integer
ATTRIBUTE USR-NFAS-ID 0xBE60 integer
ATTRIBUTE USR-Q931-Call-Reference-Value 0xBE61 integer
# Gateway-IP-Address sent with Event-Id 71,72
ATTRIBUTE USR-Gateway-IP-Address 0xBE66 ipaddr
+#
+#
+#
+ATTRIBUTE CW-Version-Id 0x8000 integer
+ATTRIBUTE CW-Account-Id 0x8001 string
+ATTRIBUTE CW-Acct-Type 0x8002 integer
+ATTRIBUTE CW-Acct-Identification-Code 0x8003 integer
+ATTRIBUTE CW-Service-Type 0x8004 integer
+ATTRIBUTE CW-Rate-Plan-Id 0x8005 integer
+ATTRIBUTE CW-Source-Identifier 0x8006 integer
+ATTRIBUTE CW-Session-Id 0x8007 string
+ATTRIBUTE CW-Num-Call-Attempt-Session 0x8008 integer
+ATTRIBUTE CW-Session-Sequence-Num 0x8009 integer
+ATTRIBUTE CW-Session-Sequence-End 0x800a integer
+ATTRIBUTE CW-Authentication-Fail-Cnt 0x800b integer
+ATTRIBUTE CW-Clg-Party-E164-Type 0x800c integer
+ATTRIBUTE CW-Clg-Party-E164-Number 0x800d string
+ATTRIBUTE CW-Clg-Party-Trans-Protocol 0x800e integer
+ATTRIBUTE CW-Clg-Party-Trans-Port 0x800f integer
+ATTRIBUTE CW-Clg-Party-Trans-IP 0x8010 ipaddr
+ATTRIBUTE CW-Clg-Party-Trans-DNS 0x8011 string
+ATTRIBUTE CW-Cld-Party-E164-Type 0x8012 integer
+ATTRIBUTE CW-Cld-Party-E164-Number 0x8013 string
+ATTRIBUTE CW-Cld-Party-Trans-Protocol 0x8014 integer
+ATTRIBUTE CW-Cld-Party-Trans-Port 0x8015 integer
+ATTRIBUTE CW-Cld-Party-Trans-IP 0x8016 ipaddr
+ATTRIBUTE CW-Cld-Party-Trans-DNS 0x8017 string
+ATTRIBUTE CW-Orig-Line-Identifier 0x8018 integer
+ATTRIBUTE CW-PSTN-Interface-Number 0x8019 integer
+ATTRIBUTE CW-Ingr-Gway-E164-Type 0x801a integer
+ATTRIBUTE CW-Ingr-Gway-E164-Number 0x801b string
+ATTRIBUTE CW-Ingr-Gway-Trans-Protocol 0x801c integer
+ATTRIBUTE CW-Ingr-Gway-Trans-Port 0x801d integer
+ATTRIBUTE CW-Ingr-Gway-Trans-IP 0x801e ipaddr
+ATTRIBUTE CW-Ingr-Gway-Trans-DNS 0x801f string
+ATTRIBUTE CW-Egr-Gway-Trans-Protocol 0x8020 integer
+ATTRIBUTE CW-Egr-Gway-Trans-Port 0x8021 integer
+ATTRIBUTE CW-Egr-Gway-Trans-IP 0x8022 ipaddr
+ATTRIBUTE CW-Egr-Gway-Trans-DNS 0x8023 string
+ATTRIBUTE CW-Ingr-Gtkpr-Trans-Protocol 0x8024 integer
+ATTRIBUTE CW-Ingr-Gtkpr-Trans-Port 0x8025 integer
+ATTRIBUTE CW-Ingr-Gtkpr-Trans-IP 0x8026 ipaddr
+ATTRIBUTE CW-Ingr-Gtkpr-Trans-DNS 0x8027 string
+ATTRIBUTE CW-Egr-Gtkpr-Trans-Protocol 0x8028 integer
+ATTRIBUTE CW-Egr-Gtkpr-Trans-Port 0x8029 integer
+ATTRIBUTE CW-Egr-Gtkpr-Trans-IP 0x802a ipaddr
+ATTRIBUTE CW-Egr-Gtkpr-Trans-DNS 0x802b string
+ATTRIBUTE CW-Call-Identifier 0x802c string
+ATTRIBUTE CW-Call-Type 0x802d integer
+ATTRIBUTE CW-Call-Start-Ingr-GW-Sec 0x802e string
+ATTRIBUTE CW-Call-Start-Ingr-GW-Msec 0x802f integer
+ATTRIBUTE CW-Call-Start-Time-Ans-Sec 0x8030 string
+ATTRIBUTE CW-Call-Start-Time-Ans-Msec 0x8031 integer
+ATTRIBUTE CW-Call-End-Time-Sec 0x8032 string
+ATTRIBUTE CW-Call-End-Time-Msec 0x8033 integer
+ATTRIBUTE CW-Call-Durn-Connect-Disc 0x8034 integer
+ATTRIBUTE CW-Codec-Type 0x8035 integer
+ATTRIBUTE CW-Call-Termination-Cause 0x8036 integer
+ATTRIBUTE CW-Audio-Packets-Sent 0x8037 integer
+ATTRIBUTE CW-Audio-Packets-Received 0x8038 integer
+ATTRIBUTE CW-Audio-Packets-Lost 0x8039 integer
+ATTRIBUTE CW-Audio-Packets-In-Frame 0x803a integer
+ATTRIBUTE CW-Audio-Bytes-In-Frame 0x803b integer
+ATTRIBUTE CW-Audio-Signal-In-Packet 0x803c integer
+ATTRIBUTE CW-Port-Id-For-Call 0x803d integer
+ATTRIBUTE CW-Slot-Id-For-Call 0x803e integer
+ATTRIBUTE CW-Acct-Balance-Start-Curr 0x803f integer
+ATTRIBUTE CW-Acct-Balance-Start-Amt 0x8040 integer
+ATTRIBUTE CW-Acct-Balance-Start-Dec 0x8041 integer
+ATTRIBUTE CW-Acct-Balance-Decr-Curr 0x8042 integer
+ATTRIBUTE CW-LRQ-Token 0x8043 string
+ATTRIBUTE CW-ARQ-Token 0x8044 string
+ATTRIBUTE CW-Token-Status 0x8045 integer
+ATTRIBUTE CW-SS7-Destn-Ptcode-Type 0x8046 integer
+ATTRIBUTE CW-SS7-Destn-Ptcode-Address 0x8047 integer
+ATTRIBUTE CW-SS7-Orig-Ptcode-Type 0x8048 integer
+ATTRIBUTE CW-SS7-Orig-Ptcode-Address 0x8049 integer
+ATTRIBUTE CW-SS7-CIC 0x804a integer
+ATTRIBUTE CW-MGC-Id 0x804b integer
+ATTRIBUTE CW-MG-Id 0x804c integer
+ATTRIBUTE CW-Signaling-Protocol 0x804d integer
+ATTRIBUTE CW-Protocol-Transport 0x804e integer
+ATTRIBUTE CW-Local-Sig-Trans-Protocol 0x804f integer
+ATTRIBUTE CW-Local-Sig-Trans-Port 0x8050 integer
+ATTRIBUTE CW-Local-Sig-Trans-IP 0x8051 ipaddr
+ATTRIBUTE CW-Local-Sig-Trans-DNS 0x8052 string
+ATTRIBUTE CW-Remote-Sig-Trans-Protocol 0x8053 integer
+ATTRIBUTE CW-Remote-Sig-Trans-Port 0x8054 integer
+ATTRIBUTE CW-Remote-Sig-Trans-IP 0x8055 ipaddr
+ATTRIBUTE CW-Remote-Sig-Trans-DNS 0x8056 string
+ATTRIBUTE CW-Local-MG-RTP-Protocol 0x8057 integer
+ATTRIBUTE CW-Local-MG-RTP-Port 0x8058 integer
+ATTRIBUTE CW-Local-MG-RTP-IP 0x8059 ipaddr
+ATTRIBUTE CW-Local-MG-RTP-DNS 0x805a string
+ATTRIBUTE CW-Remote-MG-RTP-Protocol 0x805b integer
+ATTRIBUTE CW-Remote-MG-RTP-Port 0x805c integer
+ATTRIBUTE CW-Remote-MG-RTP-IP 0x805d ipaddr
+ATTRIBUTE CW-Remote-MG-RTP-DNS 0x805e string
+ATTRIBUTE CW-Call-Model 0x805f integer
+ATTRIBUTE CW-Call-Plan-Id 0x8060 integer
+ATTRIBUTE CW-Trans-Cld-Party-E164-Type 0x8061 integer
+ATTRIBUTE CW-Trans-Cld-Party-E164-Num 0x8062 string
+ATTRIBUTE CW-OSP-Source-Device 0x8063 string
#
# These are CCA Radius attributes
ATTRIBUTE USR-Unauthenticated-Time 0x901D integer
ATTRIBUTE USR-Connect-Speed 0x9023 integer
ATTRIBUTE USR-Framed_IP_Address_Pool_Name 0x9024 string
-ATTRIBUTE USR-MP-EDO 0x9025 string
+ATTRIBUTE USR-MP-EDO 0x9025 string
#
# Pilgrim attributes
-#
+#
ATTRIBUTE USR-Bearer-Capabilities 0x9800 integer
ATTRIBUTE USR-Speed-Of-Connection 0x9801 integer
ATTRIBUTE USR-Max-Channels 0x9802 integer
ATTRIBUTE USR-Call-Reference-Number 0xbe7d integer
ATTRIBUTE USR-CDMA-Call-Reference-Number 0x0183 integer
ATTRIBUTE USR-Mobile-IP-Address 0x088e ipaddr
+ATTRIBUTE USR-QNC1-Service-Destination 0x08f4 ipaddr
ATTRIBUTE USR-IWF-IP-Address 0x03f4 ipaddr
ATTRIBUTE USR-Called-Party-Number 0x0890 string
ATTRIBUTE USR-Calling-Party-Number 0x088f string
ATTRIBUTE USR-Modem-Setup-Time 0x089c integer
ATTRIBUTE USR-Call-Connecting-Time 0x089d integer
ATTRIBUTE USR-Connect-Time 0x089e integer
-ATTRIBUTE USR-RMMIE-Last-Update-Time 0x0900 integer
+ATTRIBUTE USR-RMMIE-Last-Update-Time 0x0900 integer
ATTRIBUTE USR-RMMIE-Rcv-Tot-PwrLvl 0x0902 integer
ATTRIBUTE USR-RMMIE-Rcv-PwrLvl-3300Hz 0x0903 integer
ATTRIBUTE USR-RMMIE-Rcv-PwrLvl-3750Hz 0x0904 integer
ATTRIBUTE USR-CUSR-hat-Script-Rules 0x9866 string
ATTRIBUTE USR-Rad-Location-Type 0x9867 integer
ATTRIBUTE USR-OSPF-Addressless-Index 0x9869 integer
+ATTRIBUTE USR-QoS-Queuing-Mehtod 0x986d integer
+ATTRIBUTE USR-PQ-Default-Priority 0x986e integer
+ATTRIBUTE USR-FQ-Default-Priority 0x9871 integer
+ATTRIBUTE USR-IPP-Enable 0x9872 integer
+ATTRIBUTE USR-Pre-Shared-MN-Key 0x9873 string
+ATTRIBUTE USR-MIP-NAI 0x9874 integer
ATTRIBUTE USR-DNIS-ReAuthentication 0x9875 integer
+ATTRIBUTE USR-Agent 0x9876 integer
+ATTRIBUTE USR-PQ-Parameters 0x9877 integer
+ATTRIBUTE USR-Dvmrp-Prune-Lifetime 0x9878 integer
+ATTRIBUTE USR-Special-Xon-Xoff-Flow 0x9879 integer
+ATTRIBUTE USR-Dvmrp-Advertised-Metric 0x987a integer
+ATTRIBUTE USR-Dvmrp-Retransmit-Prunes 0x987b integer
+ATTRIBUTE USR-Dvmrp-Non-Pruners 0x987c integer
+ATTRIBUTE USR-Dvmrp-Route-Transit 0x987d integer
+ATTRIBUTE USR-Dvmrp-Input-Filter 0x987e string
+ATTRIBUTE USR-Dvmrp-Output-Filter 0x9880 string
+ATTRIBUTE USR-Policy-Access 0x9881 integer
+ATTRIBUTE USR-Policy-Configuration 0x9882 integer
+ATTRIBUTE USR-Policy-Filename 0x9883 string
+ATTRIBUTE USR-Policy-Type 0x9884 integer
+ATTRIBUTE USR-Mobile-Session-ID 0x9885 integer
+ATTRIBUTE USR-Mobile-Accounting-Type 0x9886 integer
+ATTRIBUTE USR-Mobile-Service-Option 0x9887 integer
+ATTRIBUTE USR-Wallclock-Timestamp 0x9888 integer
+ATTRIBUTE USR-Dvmrp-Initial-Flooding 0x988a integer
+ATTRIBUTE USR-Telnet-Options 0x988c integer
+ATTRIBUTE USR-CDMA-PktData-Network-ID 0x988d integer
+ATTRIBUTE USR-Auth-Next-Server-Address 0x988e ipaddr
+ATTRIBUTE USR-User-PPP-AODI-Type 0x988f integer
+ATTRIBUTE USR-MLPPP-Fragmentation-Threshld 0x9890 integer
+ATTRIBUTE USR-Unnumbered-Local-IP-Address 0x9891 ipaddr
+ATTRIBUTE USR-Traffic-Threshold 0x9892 integer
+ATTRIBUTE USR-Keep-Alive-Interval 0x9893 integer
+ATTRIBUTE USR-Tunnel-Challenge-Outgoing 0x9894 integer
+ATTRIBUTE USR-X25-Trunk-Profile 0x9895 string
+ATTRIBUTE USR-X25-Acct-Input-Segment-Count 0x9896 integer
+ATTRIBUTE USR-X25-Acct-Output-Segment-Coun 0x9897 integer
+ATTRIBUTE USR-X25-Acct-Segment-Size 0x9898 integer
+ATTRIBUTE USR-X25-Acct-Termination-Code 0x9899 integer
+ATTRIBUTE USR-X25-SVC-Logical-Channel-Numb 0x989a integer
+ATTRIBUTE USR-Nailed-B-Channel-Indicator 0x989b integer
+ATTRIBUTE USR-X25-SVC-Call-Attributes 0x989c integer
+ATTRIBUTE USR-Init-Reg-Server-Addr 0x989d ipaddr
+ATTRIBUTE USR-Re-Reg-Server-Addr 0x989e ipaddr
+ATTRIBUTE USR-Bytes-TX-Remain 0x989f integer
+ATTRIBUTE USR-Bytes-RX-Remain 0x98a0 integer
+ATTRIBUTE USR-Session-Time-Remain 0x98a1 integer
+ATTRIBUTE USR-Pre-Paid-Enabled 0x98a2 integer
+ATTRIBUTE USR-Reg-Server-Prov-Timeout 0x98a3 integer
+ATTRIBUTE USR-Redirect 0x98a4 integer
+ATTRIBUTE USR-VLAN-Tag 0x98a5 integer
+ATTRIBUTE USR-Rad-IP-Pool-Definition 0x98a6 string
+ATTRIBUTE USR-Rad-NMC-Call-Progress-Status 0x98a7 integer
+ATTRIBUTE USR-Rad-NMC-Blocks_RX 0x98a8 integer
+
ATTRIBUTE USR-NAS-Type 0xf002 integer
ATTRIBUTE USR-Auth-Mode 0xf003 integer
#
#VALUE USR-Character-Echo Echo-On 0
#VALUE USR-Character-Echo Echo-Off 1
-VALUE USR-PW_Framed_Routing_V2 Off 0
-VALUE USR-PW_Framed_Routing_V2 On 1
-
-VALUE USR-Syslog-Tap Off 0
-VALUE USR-Syslog-Tap On-Raw 1
-VALUE USR-Syslog-Tap On-Framed 2
-VALUE USR-Syslog-Tap Unknown 4294967295
+VALUE USR-PW_Framed_Routing_V2 Off 0
+VALUE USR-PW_Framed_Routing_V2 On 1
+VALUE USR-Syslog-Tap Off 0
+VALUE USR-Syslog-Tap On-Raw 1
+VALUE USR-Syslog-Tap On-Framed 2
+VALUE USR-Syslog-Tap Unknown 4294967295
# Event Indentifiers
-VALUE USR-Event-Id Module-Inserted 6
-VALUE USR-Event-Id Module-Removed 7
-VALUE USR-Event-Id PSU-Voltage-Alarm 8
-VALUE USR-Event-Id PSU-Failed 9
-VALUE USR-Event-Id HUB-Temp-Out-of-Range 10
-VALUE USR-Event-Id Fan-Failed 11
-VALUE USR-Event-Id Watchdog-Timeout 12
-VALUE USR-Event-Id Mgmt-Bus-Failure 13
-VALUE USR-Event-Id In-Connection-Est 14
-VALUE USR-Event-Id Out-Connection-Est 15
-VALUE USR-Event-Id In-Connection-Term 16
-VALUE USR-Event-Id Out-Connection-Term 17
-VALUE USR-Event-Id Connection-Failed 18
-VALUE USR-Event-Id Connection-Timeout 19
-VALUE USR-Event-Id DTE-Transmit-Idle 20
-VALUE USR-Event-Id DTR-True 21
-VALUE USR-Event-Id DTR-False 22
-VALUE USR-Event-Id Block-Error-at-Threshold 23
-VALUE USR-Event-Id Fallbacks-at-Threshold 24
-VALUE USR-Event-Id No-Dial-Tone-Detected 25
-VALUE USR-Event-Id No-Loop-Current-Detected 26
-VALUE USR-Event-Id Yellow-Alarm 27
-VALUE USR-Event-Id Red-Alarm 28
-VALUE USR-Event-Id Loss-Of-Signal 29
-VALUE USR-Event-Id Rcv-Alrm-Ind-Signal 30
-VALUE USR-Event-Id Timing-Source-Switch 31
-VALUE USR-Event-Id Modem-Reset-by-DTE 32
-VALUE USR-Event-Id Modem-Ring-No-Answer 33
-VALUE USR-Event-Id DTE-Ring-No-Answer 34
-VALUE USR-Event-Id Pkt-Bus-Session-Active 35
-VALUE USR-Event-Id Pkt-Bus-Session-Congestion 36
-VALUE USR-Event-Id Pkt-Bus-Session-Lost 37
-VALUE USR-Event-Id Pkt-Bus-Session-Inactive 38
-VALUE USR-Event-Id User-Interface-Reset 39
-VALUE USR-Event-Id Gateway-Port-Out-of-Service 40
-VALUE USR-Event-Id Gateway-Port-Link-Active 41
-VALUE USR-Event-Id Dial-Out-Login-Failure 42
-VALUE USR-Event-Id Dial-In-Login-Failure 43
-VALUE USR-Event-Id Dial-Out-Restricted-Number 44
-VALUE USR-Event-Id Dial-Back-Restricted-Number 45
-VALUE USR-Event-Id User-Blacklisted 46
-VALUE USR-Event-Id Attempted-Login-Blacklisted 47
-VALUE USR-Event-Id Response-Attempt-Limit-Exceeded 48
-VALUE USR-Event-Id Login-Attempt-Limit-Exceeded 49
-VALUE USR-Event-Id Dial-Out-Call-Duration 50
-VALUE USR-Event-Id Dial-In-Call-Duration 51
-VALUE USR-Event-Id Pkt-Bus-Session-Err-Status 52
-VALUE USR-Event-Id NMC-AutoRespnse-Trap 53
-VALUE USR-Event-Id Acct-Server-Contact-Loss 54
-VALUE USR-Event-Id Yellow-Alarm-Clear 55
-VALUE USR-Event-Id Red-Alarm-Clear 56
-VALUE USR-Event-Id Loss-Of-Signal-Clear 57
-VALUE USR-Event-Id Rcv-Alrm-Ind-Signal-Clear 58
-VALUE USR-Event-Id Incoming-Connection-Established 59
-VALUE USR-Event-Id Outgoing-Connection-Established 60
-VALUE USR-Event-Id Incoming-Connection-Terminated 61
-VALUE USR-Event-Id Outgoing-Connection-Terminated 62
-VALUE USR-Event-Id Connection-Attempt-Failure 63
-VALUE USR-Event-Id Continuous-CRC-Alarm 64
-VALUE USR-Event-Id Continuous-CRC-Alarm-Clear 65
-VALUE USR-Event-Id Physical-State-Change 66
-VALUE USR-Event-Id Gateway-Network-Failed 71
-VALUE USR-Event-Id Gateway-Network-Restored 72
-VALUE USR-Event-Id Packet-Bus-Clock-Lost 73
-VALUE USR-Event-Id Packet-Bus-Clock-Restored 74
-VALUE USR-Event-Id D-Channel-In-Service 75
-VALUE USR-Event-Id D-Channel-Out-of-Service 76
-VALUE USR-Event-Id DS0s-In-Service 77
-VALUE USR-Event-Id DS0s-Out-of-Service 78
-VALUE USR-Event-Id T1/T1PRI/E1PRI-Call-Event 79
-VALUE USR-Event-Id Psu-Incompatible 80
-VALUE USR-Event-Id T1,T1-E1/PRI-Call-Arrive-Event 81
-VALUE USR-Event-Id T1,T1-E1/PRI-Call-Connect-Event 82
-VALUE USR-Event-Id T1,T1-E1/PRI-Call-Termina-Event 83
-VALUE USR-Event-Id T1,T1-E1/PRI-Call-Failed-Event 84
-VALUE USR-Event-Id DNS-Contact-Lost 85
-VALUE USR-Event-Id NTP-Contact-Lost 86
-VALUE USR-Event-Id NTP-Contact-Restored 87
-VALUE USR-Event-Id IPGW-Link-Up 88
-VALUE USR-Event-Id IPGW-Link-Down 89
-VALUE USR-Event-Id NTP-Contact-Degraded 90
-VALUE USR-Event-Id In-Connection-Failed 91
-VALUE USR-Event-Id Out-Connection-Failed 92
-VALUE USR-Event-Id Application-ProcessorReset 93
-VALUE USR-Event-Id DSP-Reset 94
-VALUE USR-Event-Id Changed-to-Maint-Srvs-State 95
-VALUE USR-Event-Id Loop-Back-cleared-on-channel 96
-VALUE USR-Event-Id Loop-Back-on-channel 97
-VALUE USR-Event-Id Telco-Abnormal-Response 98
-VALUE USR-Event-Id DNS-Contact-Restored 99
-VALUE USR-Event-Id DNS-Contact-Degraded 100
-VALUE USR-Event-Id RADIUS-Accounting-Restored 101
-VALUE USR-Event-Id RADIUS-Accounting-Group-Restore 102
-VALUE USR-Event-Id RADIUS-Accounting-Group-Degrade 103
-VALUE USR-Event-Id RADIUS-Accounting-Group-NonOper 104
-VALUE USR-Event-Id T1/T1-E1/PRI-InCall-Fail-Event 119
-VALUE USR-Event-Id T1/T1-E1/PRI-OutCall-Fail-Event 120
-VALUE USR-Event-Id RMMIE-Retrain-Event 121
-VALUE USR-Event-Id RMMIE-Speed-Shift-Event 122
-VALUE USR-Event-Id CDMA-Call-Start 191
-VALUE USR-Event-Id CDMA-Call-End 192
-
-
-VALUE USR-Card-Type SlotEmpty 1
-VALUE USR-Card-Type SlotUnknown 2
-VALUE USR-Card-Type NetwMgtCard 3
-VALUE USR-Card-Type DualT1NAC 4
-VALUE USR-Card-Type DualModemNAC 5
-VALUE USR-Card-Type QuadModemNAC 6
-VALUE USR-Card-Type TrGatewayNAC 7
-VALUE USR-Card-Type X25GatewayNAC 8
-VALUE USR-Card-Type DualV34ModemNAC 9
-VALUE USR-Card-Type QuadV32DigitalModemNAC 10
-VALUE USR-Card-Type QuadV32AnalogModemNAC 11
-VALUE USR-Card-Type QuadV32DigAnlModemNAC 12
-VALUE USR-Card-Type QuadV34DigModemNAC 13
-VALUE USR-Card-Type QuadV34AnlModemNAC 14
-VALUE USR-Card-Type QuadV34DigAnlModemNAC 15
-VALUE USR-Card-Type SingleT1NAC 16
-VALUE USR-Card-Type EthernetGatewayNAC 17
-VALUE USR-Card-Type AccessServer 18
-VALUE USR-Card-Type 486TrGatewayNAC 19
-VALUE USR-Card-Type 486EthernetGatewayNAC 20
-VALUE USR-Card-Type DualRS232NAC 22
-VALUE USR-Card-Type 486X25GatewayNAC 23
-VALUE USR-Card-Type ApplicationServerNAC 25
-VALUE USR-Card-Type ISDNGatewayNAC 26
-VALUE USR-Card-Type ISDNpriT1NAC 27
-VALUE USR-Card-Type ClkedNetMgtCard 28
-VALUE USR-Card-Type ModemPoolManagementNAC 29
-VALUE USR-Card-Type ModemPoolNetserverNAC 30
-VALUE USR-Card-Type ModemPoolV34ModemNAC 31
-VALUE USR-Card-Type ModemPoolISDNNAC 32
-VALUE USR-Card-Type NTServerNAC 33
-VALUE USR-Card-Type QuadV34DigitalG2NAC 34
-VALUE USR-Card-Type QuadV34AnalogG2NAC 35
-VALUE USR-Card-Type QuadV34DigAnlgG2NAC 36
-VALUE USR-Card-Type NETServerFrameRelayNAC 37
-VALUE USR-Card-Type NETServerTokenRingNAC 38
-VALUE USR-Card-Type X2524ChannelNAC 39
-VALUE USR-Card-Type WirelessGatewayNac 42
-
-VALUE USR-Card-Type EnhancedAccessServer 44
-VALUE USR-Card-Type EnhancedISDNGatewayNAC 45
-
-VALUE USR-Card-Type DualT1NIC 1001
-VALUE USR-Card-Type DualAlogMdmNIC 1002
-VALUE USR-Card-Type QuadDgtlMdmNIC 1003
-VALUE USR-Card-Type QuadAlogDgtlMdmNIC 1004
-VALUE USR-Card-Type TokenRingNIC 1005
-VALUE USR-Card-Type SingleT1NIC 1006
-VALUE USR-Card-Type EthernetNIC 1007
-VALUE USR-Card-Type ShortHaulDualT1NIC 1008
-VALUE USR-Card-Type DualAlogMgdIntlMdmNIC 1009
-VALUE USR-Card-Type X25NIC 1010
-VALUE USR-Card-Type QuadAlogNonMgdMdmNIC 1011
-VALUE USR-Card-Type QuadAlogMgdIntlMdmNIC 1012
-VALUE USR-Card-Type QuadAlogNonMgdIntlMdmNIC 1013
-VALUE USR-Card-Type QuadLsdLiMgdMdmNIC 1014
-VALUE USR-Card-Type QuadLsdLiNonMgdMdmNIC 1015
-VALUE USR-Card-Type QuadLsdLiMgdIntlMdmNIC 1016
-VALUE USR-Card-Type QuadLsdLiNonMgdIntlMdmNIC 1017
-VALUE USR-Card-Type HSEthernetWithV35NIC 1018
-VALUE USR-Card-Type HSEthernetWithoutV35NIC 1019
-VALUE USR-Card-Type DualHighSpeedV35NIC 1020
-VALUE USR-Card-Type QuadV35RS232LowSpeedNIC 1021
-VALUE USR-Card-Type DualE1NIC 1022
-VALUE USR-Card-Type ShortHaulDualE1NIC 1023
-VALUE USR-Card-Type BellcoreLongHaulDualT1NIC 1025
-VALUE USR-Card-Type BellcoreShrtHaulDualT1NIC 1026
-VALUE USR-Card-Type SCSIEdgeServerNIC 1027
-
-
-VALUE USR-Default-DTE-Data-Rate 110-BPS 1
-VALUE USR-Default-DTE-Data-Rate 300-BPS 2
-VALUE USR-Default-DTE-Data-Rate 600-BPS 3
-VALUE USR-Default-DTE-Data-Rate 1200-BPS 4
-VALUE USR-Default-DTE-Data-Rate 2400-BPS 5
-VALUE USR-Default-DTE-Data-Rate 4800-BPS 6
-VALUE USR-Default-DTE-Data-Rate 7200-BPS 7
-VALUE USR-Default-DTE-Data-Rate 9600-BPS 8
-VALUE USR-Default-DTE-Data-Rate 12K-BPS 9
-VALUE USR-Default-DTE-Data-Rate 14.4K-BPS 10
-VALUE USR-Default-DTE-Data-Rate 16.8-BPS 11
-VALUE USR-Default-DTE-Data-Rate 19.2K-BPS 12
-VALUE USR-Default-DTE-Data-Rate 38.4K-BPS 13
-VALUE USR-Default-DTE-Data-Rate 75-BPS 14
-VALUE USR-Default-DTE-Data-Rate 450-BPS 15
-VALUE USR-Default-DTE-Data-Rate UNKNOWN-BPS 16
-VALUE USR-Default-DTE-Data-Rate 57.6K-BPS 17
-VALUE USR-Default-DTE-Data-Rate 21.6K-BPS 18
-VALUE USR-Default-DTE-Data-Rate 24K-BPS 19
-VALUE USR-Default-DTE-Data-Rate 26K-BPS 20
-VALUE USR-Default-DTE-Data-Rate 28K-BPS 21
-VALUE USR-Default-DTE-Data-Rate 115K-BPS 22
-
-
-VALUE USR-Initial-Rx-Link-Data-Rate 110-BPS 1
-VALUE USR-Initial-Rx-Link-Data-Rate 300-BPS 2
-VALUE USR-Initial-Rx-Link-Data-Rate 600-BPS 3
-VALUE USR-Initial-Rx-Link-Data-Rate 1200-BPS 4
-VALUE USR-Initial-Rx-Link-Data-Rate 2400-BPS 5
-VALUE USR-Initial-Rx-Link-Data-Rate 4800-BPS 6
-VALUE USR-Initial-Rx-Link-Data-Rate 7200-BPS 7
-VALUE USR-Initial-Rx-Link-Data-Rate 9600-BPS 8
-VALUE USR-Initial-Rx-Link-Data-Rate 12000-BPS 9
-VALUE USR-Initial-Rx-Link-Data-Rate 14400-BPS 10
-VALUE USR-Initial-Rx-Link-Data-Rate 16800-BPS 11
-VALUE USR-Initial-Rx-Link-Data-Rate 19200-BPS 12
-VALUE USR-Initial-Rx-Link-Data-Rate 38400-BPS 13
-VALUE USR-Initial-Rx-Link-Data-Rate 75-BPS 14
-VALUE USR-Initial-Rx-Link-Data-Rate 450-BPS 15
-VALUE USR-Initial-Rx-Link-Data-Rate UNKNOWN-BPS 16
-VALUE USR-Initial-Rx-Link-Data-Rate 57600-BPS 17
-VALUE USR-Initial-Rx-Link-Data-Rate 21600-BPS 18
-VALUE USR-Initial-Rx-Link-Data-Rate 24000-BPS 19
-VALUE USR-Initial-Rx-Link-Data-Rate 26400-BPS 20
-VALUE USR-Initial-Rx-Link-Data-Rate 28800-BPS 21
-VALUE USR-Initial-Rx-Link-Data-Rate 115200-BPS 22
-VALUE USR-Initial-Rx-Link-Data-Rate 31200-BPS 23
-VALUE USR-Initial-Rx-Link-Data-Rate 33600-BPS 24
-VALUE USR-Initial-Rx-Link-Data-Rate 25333-BPS 25
-VALUE USR-Initial-Rx-Link-Data-Rate 26666-BPS 26
-VALUE USR-Initial-Rx-Link-Data-Rate 28000-BPS 27
-VALUE USR-Initial-Rx-Link-Data-Rate 29333-BPS 28
-VALUE USR-Initial-Rx-Link-Data-Rate 30666-BPS 29
-VALUE USR-Initial-Rx-Link-Data-Rate 32000-BPS 30
-VALUE USR-Initial-Rx-Link-Data-Rate 33333-BPS 31
-VALUE USR-Initial-Rx-Link-Data-Rate 34666-BPS 32
-VALUE USR-Initial-Rx-Link-Data-Rate 36000-BPS 33
-VALUE USR-Initial-Rx-Link-Data-Rate 37333-BPS 34
-VALUE USR-Initial-Rx-Link-Data-Rate 38666-BPS 35
-VALUE USR-Initial-Rx-Link-Data-Rate 40000-BPS 36
-VALUE USR-Initial-Rx-Link-Data-Rate 41333-BPS 37
-VALUE USR-Initial-Rx-Link-Data-Rate 42666-BPS 38
-VALUE USR-Initial-Rx-Link-Data-Rate 44000-BPS 39
-VALUE USR-Initial-Rx-Link-Data-Rate 45333-BPS 40
-VALUE USR-Initial-Rx-Link-Data-Rate 46666-BPS 41
-VALUE USR-Initial-Rx-Link-Data-Rate 48000-BPS 42
-VALUE USR-Initial-Rx-Link-Data-Rate 49333-BPS 43
-VALUE USR-Initial-Rx-Link-Data-Rate 50666-BPS 44
-VALUE USR-Initial-Rx-Link-Data-Rate 52000-BPS 45
-VALUE USR-Initial-Rx-Link-Data-Rate 53333-BPS 46
-VALUE USR-Initial-Rx-Link-Data-Rate 54666-BPS 47
-VALUE USR-Initial-Rx-Link-Data-Rate 56000-BPS 48
-VALUE USR-Initial-Rx-Link-Data-Rate 57333-BPS 49
-VALUE USR-Initial-Rx-Link-Data-Rate 58666-BPS 50
-VALUE USR-Initial-Rx-Link-Data-Rate 60000-BPS 51
-VALUE USR-Initial-Rx-Link-Data-Rate 61333-BPS 52
-VALUE USR-Initial-Rx-Link-Data-Rate 62666-BPS 53
-VALUE USR-Initial-Rx-Link-Data-Rate 64000-BPS 54
-
-
-
-VALUE USR-Final-Rx-Link-Data-Rate 110-BPS 1
-VALUE USR-Final-Rx-Link-Data-Rate 300-BPS 2
-VALUE USR-Final-Rx-Link-Data-Rate 600-BPS 3
-VALUE USR-Final-Rx-Link-Data-Rate 1200-BPS 4
-VALUE USR-Final-Rx-Link-Data-Rate 2400-BPS 5
-VALUE USR-Final-Rx-Link-Data-Rate 4800-BPS 6
-VALUE USR-Final-Rx-Link-Data-Rate 7200-BPS 7
-VALUE USR-Final-Rx-Link-Data-Rate 9600-BPS 8
-VALUE USR-Final-Rx-Link-Data-Rate 12000-BPS 9
-VALUE USR-Final-Rx-Link-Data-Rate 14400-BPS 10
-VALUE USR-Final-Rx-Link-Data-Rate 16800-BPS 11
-VALUE USR-Final-Rx-Link-Data-Rate 19200-BPS 12
-VALUE USR-Final-Rx-Link-Data-Rate 38400-BPS 13
-VALUE USR-Final-Rx-Link-Data-Rate 75-BPS 14
-VALUE USR-Final-Rx-Link-Data-Rate 450-BPS 15
-VALUE USR-Final-Rx-Link-Data-Rate UNKNOWN-BPS 16
-VALUE USR-Final-Rx-Link-Data-Rate 57600-BPS 17
-VALUE USR-Final-Rx-Link-Data-Rate 21600-BPS 18
-VALUE USR-Final-Rx-Link-Data-Rate 24000-BPS 19
-VALUE USR-Final-Rx-Link-Data-Rate 26400-BPS 20
-VALUE USR-Final-Rx-Link-Data-Rate 28800-BPS 21
-VALUE USR-Final-Rx-Link-Data-Rate 115200-BPS 22
-VALUE USR-Final-Rx-Link-Data-Rate 31200-BPS 23
-VALUE USR-Final-Rx-Link-Data-Rate 33600-BPS 24
-VALUE USR-Final-Rx-Link-Data-Rate 25333-BPS 25
-VALUE USR-Final-Rx-Link-Data-Rate 26666-BPS 26
-VALUE USR-Final-Rx-Link-Data-Rate 28000-BPS 27
-VALUE USR-Final-Rx-Link-Data-Rate 29333-BPS 28
-VALUE USR-Final-Rx-Link-Data-Rate 30666-BPS 29
-VALUE USR-Final-Rx-Link-Data-Rate 32000-BPS 30
-VALUE USR-Final-Rx-Link-Data-Rate 33333-BPS 31
-VALUE USR-Final-Rx-Link-Data-Rate 34666-BPS 32
-VALUE USR-Final-Rx-Link-Data-Rate 36000-BPS 33
-VALUE USR-Final-Rx-Link-Data-Rate 37333-BPS 34
-VALUE USR-Final-Rx-Link-Data-Rate 38666-BPS 35
-VALUE USR-Final-Rx-Link-Data-Rate 40000-BPS 36
-VALUE USR-Final-Rx-Link-Data-Rate 41333-BPS 37
-VALUE USR-Final-Rx-Link-Data-Rate 42666-BPS 38
-VALUE USR-Final-Rx-Link-Data-Rate 44000-BPS 39
-VALUE USR-Final-Rx-Link-Data-Rate 45333-BPS 40
-VALUE USR-Final-Rx-Link-Data-Rate 46666-BPS 41
-VALUE USR-Final-Rx-Link-Data-Rate 48000-BPS 42
-VALUE USR-Final-Rx-Link-Data-Rate 49333-BPS 43
-VALUE USR-Final-Rx-Link-Data-Rate 50666-BPS 44
-VALUE USR-Final-Rx-Link-Data-Rate 52000-BPS 45
-VALUE USR-Final-Rx-Link-Data-Rate 53333-BPS 46
-VALUE USR-Final-Rx-Link-Data-Rate 54666-BPS 47
-VALUE USR-Final-Rx-Link-Data-Rate 56000-BPS 48
-VALUE USR-Final-Rx-Link-Data-Rate 57333-BPS 49
-VALUE USR-Final-Rx-Link-Data-Rate 58666-BPS 50
-VALUE USR-Final-Rx-Link-Data-Rate 60000-BPS 51
-VALUE USR-Final-Rx-Link-Data-Rate 61333-BPS 52
-VALUE USR-Final-Rx-Link-Data-Rate 62666-BPS 53
-VALUE USR-Final-Rx-Link-Data-Rate 64000-BPS 54
-
-
-VALUE USR-Initial-Tx-Link-Data-Rate 110-BPS 1
-VALUE USR-Initial-Tx-Link-Data-Rate 300-BPS 2
-VALUE USR-Initial-Tx-Link-Data-Rate 600-BPS 3
-VALUE USR-Initial-Tx-Link-Data-Rate 1200-BPS 4
-VALUE USR-Initial-Tx-Link-Data-Rate 2400-BPS 5
-VALUE USR-Initial-Tx-Link-Data-Rate 4800-BPS 6
-VALUE USR-Initial-Tx-Link-Data-Rate 7200-BPS 7
-VALUE USR-Initial-Tx-Link-Data-Rate 9600-BPS 8
-VALUE USR-Initial-Tx-Link-Data-Rate 12000-BPS 9
-VALUE USR-Initial-Tx-Link-Data-Rate 14400-BPS 10
-VALUE USR-Initial-Tx-Link-Data-Rate 16800-BPS 11
-VALUE USR-Initial-Tx-Link-Data-Rate 19200-BPS 12
-VALUE USR-Initial-Tx-Link-Data-Rate 38400-BPS 13
-VALUE USR-Initial-Tx-Link-Data-Rate 75-BPS 14
-VALUE USR-Initial-Tx-Link-Data-Rate 450-BPS 15
-VALUE USR-Initial-Tx-Link-Data-Rate UNKNOWN-BPS 16
-VALUE USR-Initial-Tx-Link-Data-Rate 57600-BPS 17
-VALUE USR-Initial-Tx-Link-Data-Rate 21600-BPS 18
-VALUE USR-Initial-Tx-Link-Data-Rate 24000-BPS 19
-VALUE USR-Initial-Tx-Link-Data-Rate 26400-BPS 20
-VALUE USR-Initial-Tx-Link-Data-Rate 28800-BPS 21
-VALUE USR-Initial-Tx-Link-Data-Rate 115200-BPS 22
-VALUE USR-Initial-Tx-Link-Data-Rate 31200-BPS 23
-VALUE USR-Initial-Tx-Link-Data-Rate 33600-BPS 24
-VALUE USR-Initial-Tx-Link-Data-Rate 25333-BPS 25
-VALUE USR-Initial-Tx-Link-Data-Rate 26666-BPS 26
-VALUE USR-Initial-Tx-Link-Data-Rate 28000-BPS 27
-VALUE USR-Initial-Tx-Link-Data-Rate 29333-BPS 28
-VALUE USR-Initial-Tx-Link-Data-Rate 30666-BPS 29
-VALUE USR-Initial-Tx-Link-Data-Rate 32000-BPS 30
-VALUE USR-Initial-Tx-Link-Data-Rate 33333-BPS 31
-VALUE USR-Initial-Tx-Link-Data-Rate 34666-BPS 32
-VALUE USR-Initial-Tx-Link-Data-Rate 36000-BPS 33
-VALUE USR-Initial-Tx-Link-Data-Rate 37333-BPS 34
-VALUE USR-Initial-Tx-Link-Data-Rate 38666-BPS 35
-VALUE USR-Initial-Tx-Link-Data-Rate 40000-BPS 36
-VALUE USR-Initial-Tx-Link-Data-Rate 41333-BPS 37
-VALUE USR-Initial-Tx-Link-Data-Rate 42666-BPS 38
-VALUE USR-Initial-Tx-Link-Data-Rate 44000-BPS 39
-VALUE USR-Initial-Tx-Link-Data-Rate 45333-BPS 40
-VALUE USR-Initial-Tx-Link-Data-Rate 46666-BPS 41
-VALUE USR-Initial-Tx-Link-Data-Rate 48000-BPS 42
-VALUE USR-Initial-Tx-Link-Data-Rate 49333-BPS 43
-VALUE USR-Initial-Tx-Link-Data-Rate 50666-BPS 44
-VALUE USR-Initial-Tx-Link-Data-Rate 52000-BPS 45
-VALUE USR-Initial-Tx-Link-Data-Rate 53333-BPS 46
-VALUE USR-Initial-Tx-Link-Data-Rate 54666-BPS 47
-VALUE USR-Initial-Tx-Link-Data-Rate 56000-BPS 48
-VALUE USR-Initial-Tx-Link-Data-Rate 57333-BPS 49
-VALUE USR-Initial-Tx-Link-Data-Rate 58666-BPS 50
-VALUE USR-Initial-Tx-Link-Data-Rate 60000-BPS 51
-VALUE USR-Initial-Tx-Link-Data-Rate 61333-BPS 52
-VALUE USR-Initial-Tx-Link-Data-Rate 62666-BPS 53
-VALUE USR-Initial-Tx-Link-Data-Rate 64000-BPS 54
-
-
-
-VALUE USR-Final-Tx-Link-Data-Rate 110-BPS 1
-VALUE USR-Final-Tx-Link-Data-Rate 300-BPS 2
-VALUE USR-Final-Tx-Link-Data-Rate 600-BPS 3
-VALUE USR-Final-Tx-Link-Data-Rate 1200-BPS 4
-VALUE USR-Final-Tx-Link-Data-Rate 2400-BPS 5
-VALUE USR-Final-Tx-Link-Data-Rate 4800-BPS 6
-VALUE USR-Final-Tx-Link-Data-Rate 7200-BPS 7
-VALUE USR-Final-Tx-Link-Data-Rate 9600-BPS 8
-VALUE USR-Final-Tx-Link-Data-Rate 12000-BPS 9
-VALUE USR-Final-Tx-Link-Data-Rate 14400-BPS 10
-VALUE USR-Final-Tx-Link-Data-Rate 16800-BPS 11
-VALUE USR-Final-Tx-Link-Data-Rate 19200-BPS 12
-VALUE USR-Final-Tx-Link-Data-Rate 38400-BPS 13
-VALUE USR-Final-Tx-Link-Data-Rate 75-BPS 14
-VALUE USR-Final-Tx-Link-Data-Rate 450-BPS 15
-VALUE USR-Final-Tx-Link-Data-Rate UNKNOWN-BPS 16
-VALUE USR-Final-Tx-Link-Data-Rate 57600-BPS 17
-VALUE USR-Final-Tx-Link-Data-Rate 21600-BPS 18
-VALUE USR-Final-Tx-Link-Data-Rate 24000-BPS 19
-VALUE USR-Final-Tx-Link-Data-Rate 26400-BPS 20
-VALUE USR-Final-Tx-Link-Data-Rate 28800-BPS 21
-VALUE USR-Final-Tx-Link-Data-Rate 115200-BPS 22
-VALUE USR-Final-Tx-Link-Data-Rate 31200-BPS 23
-VALUE USR-Final-Tx-Link-Data-Rate 33600-BPS 24
-VALUE USR-Final-Tx-Link-Data-Rate 25333-BPS 25
-VALUE USR-Final-Tx-Link-Data-Rate 26666-BPS 26
-VALUE USR-Final-Tx-Link-Data-Rate 28000-BPS 27
-VALUE USR-Final-Tx-Link-Data-Rate 29333-BPS 28
-VALUE USR-Final-Tx-Link-Data-Rate 30666-BPS 29
-VALUE USR-Final-Tx-Link-Data-Rate 32000-BPS 30
-VALUE USR-Final-Tx-Link-Data-Rate 33333-BPS 31
-VALUE USR-Final-Tx-Link-Data-Rate 34666-BPS 32
-VALUE USR-Final-Tx-Link-Data-Rate 36000-BPS 33
-VALUE USR-Final-Tx-Link-Data-Rate 37333-BPS 34
-VALUE USR-Final-Tx-Link-Data-Rate 38666-BPS 35
-VALUE USR-Final-Tx-Link-Data-Rate 40000-BPS 36
-VALUE USR-Final-Tx-Link-Data-Rate 41333-BPS 37
-VALUE USR-Final-Tx-Link-Data-Rate 42666-BPS 38
-VALUE USR-Final-Tx-Link-Data-Rate 44000-BPS 39
-VALUE USR-Final-Tx-Link-Data-Rate 45333-BPS 40
-VALUE USR-Final-Tx-Link-Data-Rate 46666-BPS 41
-VALUE USR-Final-Tx-Link-Data-Rate 48000-BPS 42
-VALUE USR-Final-Tx-Link-Data-Rate 49333-BPS 43
-VALUE USR-Final-Tx-Link-Data-Rate 50666-BPS 44
-VALUE USR-Final-Tx-Link-Data-Rate 52000-BPS 45
-VALUE USR-Final-Tx-Link-Data-Rate 53333-BPS 46
-VALUE USR-Final-Tx-Link-Data-Rate 54666-BPS 47
-VALUE USR-Final-Tx-Link-Data-Rate 56000-BPS 48
-VALUE USR-Final-Tx-Link-Data-Rate 57333-BPS 49
-VALUE USR-Final-Tx-Link-Data-Rate 58666-BPS 50
-VALUE USR-Final-Tx-Link-Data-Rate 60000-BPS 51
-VALUE USR-Final-Tx-Link-Data-Rate 61333-BPS 52
-VALUE USR-Final-Tx-Link-Data-Rate 62666-BPS 53
-VALUE USR-Final-Tx-Link-Data-Rate 64000-BPS 54
-
-VALUE USR-Connect-Speed NONE 1
-VALUE USR-Connect-Speed 300-BPS 2
-VALUE USR-Connect-Speed 1200-BPS 3
-VALUE USR-Connect-Speed 2400-BPS 4
-VALUE USR-Connect-Speed 4800-BPS 5
-VALUE USR-Connect-Speed 7200-BPS 6
-VALUE USR-Connect-Speed 9600-BPS 7
-VALUE USR-Connect-Speed 12000-BPS 8
-VALUE USR-Connect-Speed 14400-BPS 9
-VALUE USR-Connect-Speed 16800-BPS 10
-VALUE USR-Connect-Speed 19200-BPS 11
-VALUE USR-Connect-Speed 21600-BPS 12
-VALUE USR-Connect-Speed 28800-BPS 13
-VALUE USR-Connect-Speed 38400-BPS 14
-VALUE USR-Connect-Speed 57600-BPS 15
-VALUE USR-Connect-Speed 115200-BPS 16
-VALUE USR-Connect-Speed 288000-BPS 17
-VALUE USR-Connect-Speed 75-1200-BPS 18
-VALUE USR-Connect-Speed 1200-75-BPS 19
-VALUE USR-Connect-Speed 24000-BPS 20
-VALUE USR-Connect-Speed 26400-BPS 21
-VALUE USR-Connect-Speed 31200-BPS 22
-VALUE USR-Connect-Speed 33600-BPS 23
-VALUE USR-Connect-Speed 33333-BPS 24
-VALUE USR-Connect-Speed 37333-BPS 25
-VALUE USR-Connect-Speed 41333-BPS 26
-VALUE USR-Connect-Speed 42666-BPS 27
-VALUE USR-Connect-Speed 44000-BPS 28
-VALUE USR-Connect-Speed 45333-BPS 29
-VALUE USR-Connect-Speed 46666-BPS 30
-VALUE USR-Connect-Speed 48000-BPS 31
-VALUE USR-Connect-Speed 49333-BPS 32
-VALUE USR-Connect-Speed 50666-BPS 33
-VALUE USR-Connect-Speed 52000-BPS 34
-VALUE USR-Connect-Speed 53333-BPS 35
-VALUE USR-Connect-Speed 54666-BPS 36
-VALUE USR-Connect-Speed 56000-BPS 37
-VALUE USR-Connect-Speed 57333-BPS 38
-VALUE USR-Connect-Speed 64000-BPS 39
-VALUE USR-Connect-Speed 25333-BPS 40
-VALUE USR-Connect-Speed 26666-BPS 41
-VALUE USR-Connect-Speed 28000-BPS 42
-VALUE USR-Connect-Speed 29333-BPS 43
-VALUE USR-Connect-Speed 30666-BPS 44
-VALUE USR-Connect-Speed 32000-BPS 45
-VALUE USR-Connect-Speed 34666-BPS 46
-VALUE USR-Connect-Speed 36000-BPS 47
-VALUE USR-Connect-Speed 38666-BPS 48
-VALUE USR-Connect-Speed 40000-BPS 49
-VALUE USR-Connect-Speed 58666-BPS 50
-VALUE USR-Connect-Speed 60000-BPS 51
-VALUE USR-Connect-Speed 61333-BPS 52
-VALUE USR-Connect-Speed 62666-BPS 53
-
-VALUE USR-Sync-Async-Mode Asynchronous 1
-VALUE USR-Sync-Async-Mode Synchronous 2
-
-VALUE USR-Originate-Answer-Mode Originate_in_Originate_Mode 1
-VALUE USR-Originate-Answer-Mode Originate_in_Answer_Mode 2
-VALUE USR-Originate-Answer-Mode Answer_in_Originate_Mode 3
-VALUE USR-Originate-Answer-Mode Answer_in_Answer_Mode 4
-
-VALUE USR-Modulation-Type usRoboticsHST 1
-VALUE USR-Modulation-Type ccittV32 2
-VALUE USR-Modulation-Type ccittV22bis 3
-VALUE USR-Modulation-Type bell103 4
-VALUE USR-Modulation-Type ccittV21 5
-VALUE USR-Modulation-Type bell212 6
-VALUE USR-Modulation-Type ccittV32bis 7
-VALUE USR-Modulation-Type ccittV23 8
-VALUE USR-Modulation-Type negotiationFailed 9
-VALUE USR-Modulation-Type bell208b 10
-VALUE USR-Modulation-Type v21FaxClass1 11
-VALUE USR-Modulation-Type v27FaxClass1 12
-VALUE USR-Modulation-Type v29FaxClass1 13
-VALUE USR-Modulation-Type v17FaxClass1 14
-VALUE USR-Modulation-Type v21FaxClass2 15
-VALUE USR-Modulation-Type v27FaxClass2 16
-VALUE USR-Modulation-Type v29FaxClass2 17
-VALUE USR-Modulation-Type v17FaxClass2 18
-VALUE USR-Modulation-Type v32Terbo 19
-VALUE USR-Modulation-Type v34 20
-VALUE USR-Modulation-Type vFC 21
-VALUE USR-Modulation-Type v34plus 22
-VALUE USR-Modulation-Type x2 23
-VALUE USR-Modulation-Type v110 24
-VALUE USR-Modulation-Type v120 25
-VALUE USR-Modulation-Type x75 26
-VALUE USR-Modulation-Type asyncSyncPPP 27
-VALUE USR-Modulation-Type clearChannel 28
-VALUE USR-Modulation-Type x2client 29
-VALUE USR-Modulation-Type x2symmetric 30
-VALUE USR-Modulation-Type piafs 31
-VALUE USR-Modulation-Type x2version2 32
-VALUE USR-Modulation-Type v90Analog 33
-VALUE USR-Modulation-Type v90Digital 34
-VALUE USR-Modulation-Type v90AllDigital 35
-
-VALUE Initial-Modulation-Type usRoboticsHST 1
-VALUE Initial-Modulation-Type ccittV32 2
-VALUE Initial-Modulation-Type ccittV22bis 3
-VALUE Initial-Modulation-Type bell103 4
-VALUE Initial-Modulation-Type ccittV21 5
-VALUE Initial-Modulation-Type bell212 6
-VALUE Initial-Modulation-Type ccittV32bis 7
-VALUE Initial-Modulation-Type ccittV23 8
-VALUE Initial-Modulation-Type negotiationFailed 9
-VALUE Initial-Modulation-Type bell208b 10
-VALUE Initial-Modulation-Type v21FaxClass1 11
-VALUE Initial-Modulation-Type v27FaxClass1 12
-VALUE Initial-Modulation-Type v29FaxClass1 13
-VALUE Initial-Modulation-Type v17FaxClass1 14
-VALUE Initial-Modulation-Type v21FaxClass2 15
-VALUE Initial-Modulation-Type v27FaxClass2 16
-VALUE Initial-Modulation-Type v29FaxClass2 17
-VALUE Initial-Modulation-Type v17FaxClass2 18
-VALUE Initial-Modulation-Type v32Terbo 19
-VALUE Initial-Modulation-Type v34 20
-VALUE Initial-Modulation-Type vFC 21
-VALUE Initial-Modulation-Type v34plus 22
-VALUE Initial-Modulation-Type x2 23
-VALUE Initial-Modulation-Type v110 24
-VALUE Initial-Modulation-Type v120 25
-VALUE Initial-Modulation-Type x75 26
-VALUE Initial-Modulation-Type asyncSyncPPP 27
-VALUE Initial-Modulation-Type clearChannel 28
-VALUE Initial-Modulation-Type x2client 29
-VALUE Initial-Modulation-Type x2symmetric 30
-VALUE Initial-Modulation-Type piafs 31
-VALUE Initial-Modulation-Type x2version2 32
-VALUE Initial-Modulation-Type v90Analogue 33
-VALUE Initial-Modulation-Type v90Digital 34
-VALUE Initial-Modulation-Type v90AllDigital 35
-
-VALUE USR-Connect-Term-Reason dtrDrop 1
-VALUE USR-Connect-Term-Reason escapeSequence 2
-VALUE USR-Connect-Term-Reason athCommand 3
-VALUE USR-Connect-Term-Reason carrierLoss 4
-VALUE USR-Connect-Term-Reason inactivityTimout 5
-VALUE USR-Connect-Term-Reason mnpIncompatible 6
-VALUE USR-Connect-Term-Reason undefined 7
-VALUE USR-Connect-Term-Reason remotePassword 8
-VALUE USR-Connect-Term-Reason linkPassword 9
-VALUE USR-Connect-Term-Reason retransmitLimit 10
-VALUE USR-Connect-Term-Reason linkDisconnectMsgReceived 11
-VALUE USR-Connect-Term-Reason noLoopCurrent 12
-VALUE USR-Connect-Term-Reason invalidSpeed 13
-VALUE USR-Connect-Term-Reason unableToRetrain 14
-VALUE USR-Connect-Term-Reason managementCommand 15
-VALUE USR-Connect-Term-Reason noDialTone 16
-VALUE USR-Connect-Term-Reason keyAbort 17
-VALUE USR-Connect-Term-Reason lineBusy 18
-VALUE USR-Connect-Term-Reason noAnswer 19
-VALUE USR-Connect-Term-Reason voice 20
-VALUE USR-Connect-Term-Reason noAnswerTone 21
-VALUE USR-Connect-Term-Reason noCarrier 22
-VALUE USR-Connect-Term-Reason undetermined 23
-VALUE USR-Connect-Term-Reason v42SabmeTimeout 24
-VALUE USR-Connect-Term-Reason v42BreakTimeout 25
-VALUE USR-Connect-Term-Reason v42DisconnectCmd 26
-VALUE USR-Connect-Term-Reason v42IdExchangeFail 27
-VALUE USR-Connect-Term-Reason v42BadSetup 28
-VALUE USR-Connect-Term-Reason v42InvalidCodeWord 29
-VALUE USR-Connect-Term-Reason v42StringToLong 30
-VALUE USR-Connect-Term-Reason v42InvalidCommand 31
-VALUE USR-Connect-Term-Reason none 32
-VALUE USR-Connect-Term-Reason v32Cleardown 33
-VALUE USR-Connect-Term-Reason dialSecurity 34
-VALUE USR-Connect-Term-Reason remoteAccessDenied 35
-VALUE USR-Connect-Term-Reason loopLoss 36
-VALUE USR-Connect-Term-Reason ds0Teardown 37
-VALUE USR-Connect-Term-Reason promptNotEnabled 38
-VALUE USR-Connect-Term-Reason noPromptingInSync 39
-VALUE USR-Connect-Term-Reason nonArqMode 40
-VALUE USR-Connect-Term-Reason modeIncompatible 41
-VALUE USR-Connect-Term-Reason noPromptInNonARQ 42
-VALUE USR-Connect-Term-Reason dialBackLink 43
-VALUE USR-Connect-Term-Reason linkAbort 44
-VALUE USR-Connect-Term-Reason autopassFailed 45
-VALUE USR-Connect-Term-Reason pbGenericError 46
-VALUE USR-Connect-Term-Reason pbLinkErrTxPreAck 47
-VALUE USR-Connect-Term-Reason pbLinkErrTxTardyACK 48
-VALUE USR-Connect-Term-Reason pbTransmitBusTimeout 49
-VALUE USR-Connect-Term-Reason pbReceiveBusTimeout 50
-VALUE USR-Connect-Term-Reason pbLinkErrTxTAL 51
-VALUE USR-Connect-Term-Reason pbLinkErrRxTAL 52
-VALUE USR-Connect-Term-Reason pbTransmitMasterTimeout 53
-VALUE USR-Connect-Term-Reason pbClockMissing 54
-VALUE USR-Connect-Term-Reason pbReceivedLsWhileLinkUp 55
-VALUE USR-Connect-Term-Reason pbOutOfSequenceFrame 56
-VALUE USR-Connect-Term-Reason pbBadFrame 57
-VALUE USR-Connect-Term-Reason pbAckWaitTimeout 58
-VALUE USR-Connect-Term-Reason pbReceivedAckSeqErr 59
-VALUE USR-Connect-Term-Reason pbReceiveOvrflwRNRFail 60
-VALUE USR-Connect-Term-Reason pbReceiveMsgBufOvrflw 61
-VALUE USR-Connect-Term-Reason rcvdGatewayDiscCmd 62
-VALUE USR-Connect-Term-Reason tokenPassingTimeout 63
-VALUE USR-Connect-Term-Reason dspInterruptTimeout 64
-VALUE USR-Connect-Term-Reason mnpProtocolViolation 65
-VALUE USR-Connect-Term-Reason class2FaxHangupCmd 66
-VALUE USR-Connect-Term-Reason hstSpeedSwitchTimeout 67
-VALUE USR-Connect-Term-Reason tooManyUnacked 68
-VALUE USR-Connect-Term-Reason timerExpired 69
-VALUE USR-Connect-Term-Reason t1Glare 70
-VALUE USR-Connect-Term-Reason priDialoutRqTimeout 71
-VALUE USR-Connect-Term-Reason abortAnlgDstOvrIsdn 72
-VALUE USR-Connect-Term-Reason normalUserCallClear 73
-VALUE USR-Connect-Term-Reason normalUnspecified 74
-VALUE USR-Connect-Term-Reason bearerIncompatibility 75
-VALUE USR-Connect-Term-Reason protocolErrorEvent 76
-VALUE USR-Connect-Term-Reason abnormalDisconnect 77
-VALUE USR-Connect-Term-Reason invalidCauseValue 78
-VALUE USR-Connect-Term-Reason resourceUnavailable 79
-VALUE USR-Connect-Term-Reason remoteHungUpDuringTraining 80
-VALUE USR-Connect-Term-Reason trainingTimeout 81
-VALUE USR-Connect-Term-Reason incomingModemNotAvailable 82
-VALUE USR-Connect-Term-Reason incomingInvalidBearerCap 83
-VALUE USR-Connect-Term-Reason incomingInvalidChannelID 84
-VALUE USR-Connect-Term-Reason incomingInvalidProgInd 85
-VALUE USR-Connect-Term-Reason incomingInvalidCallingPty 86
-VALUE USR-Connect-Term-Reason incomingInvalidCalledPty 87
-VALUE USR-Connect-Term-Reason incomingCallBlock 88
-VALUE USR-Connect-Term-Reason incomingLoopStNoRingOff 89
-VALUE USR-Connect-Term-Reason outgoingTelcoDisconnect 90
-VALUE USR-Connect-Term-Reason outgoingEMWinkTimeout 91
-VALUE USR-Connect-Term-Reason outgoingEMWinkTooShort 92
-VALUE USR-Connect-Term-Reason outgoingNoChannelAvail 93
-VALUE USR-Connect-Term-Reason dspReboot 94
-VALUE USR-Connect-Term-Reason noDSPRespToKA 95
-VALUE USR-Connect-Term-Reason noDSPRespToDisc 96
-VALUE USR-Connect-Term-Reason dspTailPtrInvalid 97
-VALUE USR-Connect-Term-Reason dspHeadPtrInvalid 98
+VALUE USR-Event-Id Module-Inserted 6
+VALUE USR-Event-Id Module-Removed 7
+VALUE USR-Event-Id PSU-Voltage-Alarm 8
+VALUE USR-Event-Id PSU-Failed 9
+VALUE USR-Event-Id HUB-Temp-Out-of-Range 10
+VALUE USR-Event-Id Fan-Failed 11
+VALUE USR-Event-Id Watchdog-Timeout 12
+VALUE USR-Event-Id Mgmt-Bus-Failure 13
+VALUE USR-Event-Id In-Connection-Est 14
+VALUE USR-Event-Id Out-Connection-Est 15
+VALUE USR-Event-Id In-Connection-Term 16
+VALUE USR-Event-Id Out-Connection-Term 17
+VALUE USR-Event-Id Connection-Failed 18
+VALUE USR-Event-Id Connection-Timeout 19
+VALUE USR-Event-Id DTE-Transmit-Idle 20
+VALUE USR-Event-Id DTR-True 21
+VALUE USR-Event-Id DTR-False 22
+VALUE USR-Event-Id Block-Error-at-Threshold 23
+VALUE USR-Event-Id Fallbacks-at-Threshold 24
+VALUE USR-Event-Id No-Dial-Tone-Detected 25
+VALUE USR-Event-Id No-Loop-Current-Detected 26
+VALUE USR-Event-Id Yellow-Alarm 27
+VALUE USR-Event-Id Red-Alarm 28
+VALUE USR-Event-Id Loss-Of-Signal 29
+VALUE USR-Event-Id Rcv-Alrm-Ind-Signal 30
+VALUE USR-Event-Id Timing-Source-Switch 31
+VALUE USR-Event-Id Modem-Reset-by-DTE 32
+VALUE USR-Event-Id Modem-Ring-No-Answer 33
+VALUE USR-Event-Id DTE-Ring-No-Answer 34
+VALUE USR-Event-Id Pkt-Bus-Session-Active 35
+VALUE USR-Event-Id Pkt-Bus-Session-Congestion 36
+VALUE USR-Event-Id Pkt-Bus-Session-Lost 37
+VALUE USR-Event-Id Pkt-Bus-Session-Inactive 38
+VALUE USR-Event-Id User-Interface-Reset 39
+VALUE USR-Event-Id Gateway-Port-Out-of-Service 40
+VALUE USR-Event-Id Gateway-Port-Link-Active 41
+VALUE USR-Event-Id Dial-Out-Login-Failure 42
+VALUE USR-Event-Id Dial-In-Login-Failure 43
+VALUE USR-Event-Id Dial-Out-Restricted-Number 44
+VALUE USR-Event-Id Dial-Back-Restricted-Number 45
+VALUE USR-Event-Id User-Blacklisted 46
+VALUE USR-Event-Id Attempted-Login-Blacklisted 47
+VALUE USR-Event-Id Response-Attempt-Limit-Exceeded 48
+VALUE USR-Event-Id Login-Attempt-Limit-Exceeded 49
+VALUE USR-Event-Id Dial-Out-Call-Duration 50
+VALUE USR-Event-Id Dial-In-Call-Duration 51
+VALUE USR-Event-Id Pkt-Bus-Session-Err-Status 52
+VALUE USR-Event-Id NMC-AutoRespnse-Trap 53
+VALUE USR-Event-Id Acct-Server-Contact-Loss 54
+VALUE USR-Event-Id Yellow-Alarm-Clear 55
+VALUE USR-Event-Id Red-Alarm-Clear 56
+VALUE USR-Event-Id Loss-Of-Signal-Clear 57
+VALUE USR-Event-Id Rcv-Alrm-Ind-Signal-Clear 58
+VALUE USR-Event-Id Incoming-Connection-Established 59
+VALUE USR-Event-Id Outgoing-Connection-Established 60
+VALUE USR-Event-Id Incoming-Connection-Terminated 61
+VALUE USR-Event-Id Outgoing-Connection-Terminated 62
+VALUE USR-Event-Id Connection-Attempt-Failure 63
+VALUE USR-Event-Id Continuous-CRC-Alarm 64
+VALUE USR-Event-Id Continuous-CRC-Alarm-Clear 65
+VALUE USR-Event-Id Physical-State-Change 66
+VALUE USR-Event-Id Gateway-Network-Failed 71
+VALUE USR-Event-Id Gateway-Network-Restored 72
+VALUE USR-Event-Id Packet-Bus-Clock-Lost 73
+VALUE USR-Event-Id Packet-Bus-Clock-Restored 74
+VALUE USR-Event-Id D-Channel-In-Service 75
+VALUE USR-Event-Id D-Channel-Out-of-Service 76
+VALUE USR-Event-Id DS0s-In-Service 77
+VALUE USR-Event-Id DS0s-Out-of-Service 78
+VALUE USR-Event-Id T1/T1PRI/E1PRI-Call-Event 79
+VALUE USR-Event-Id Psu-Incompatible 80
+VALUE USR-Event-Id T1,T1-E1/PRI-Call-Arrive-Event 81
+VALUE USR-Event-Id T1,T1-E1/PRI-Call-Connect-Event 82
+VALUE USR-Event-Id T1,T1-E1/PRI-Call-Termina-Event 83
+VALUE USR-Event-Id T1,T1-E1/PRI-Call-Failed-Event 84
+VALUE USR-Event-Id DNS-Contact-Lost 85
+VALUE USR-Event-Id NTP-Contact-Lost 86
+VALUE USR-Event-Id NTP-Contact-Restored 87
+VALUE USR-Event-Id IPGW-Link-Up 88
+VALUE USR-Event-Id IPGW-Link-Down 89
+VALUE USR-Event-Id NTP-Contact-Degraded 90
+VALUE USR-Event-Id In-Connection-Failed 91
+VALUE USR-Event-Id Out-Connection-Failed 92
+VALUE USR-Event-Id Application-ProcessorReset 93
+VALUE USR-Event-Id DSP-Reset 94
+VALUE USR-Event-Id Changed-to-Maint-Srvs-State 95
+VALUE USR-Event-Id Loop-Back-cleared-on-channel 96
+VALUE USR-Event-Id Loop-Back-on-channel 97
+VALUE USR-Event-Id Telco-Abnormal-Response 98
+VALUE USR-Event-Id DNS-Contact-Restored 99
+VALUE USR-Event-Id DNS-Contact-Degraded 100
+VALUE USR-Event-Id RADIUS-Accounting-Restored 101
+VALUE USR-Event-Id RADIUS-Accounting-Group-Restore 102
+VALUE USR-Event-Id RADIUS-Accounting-Group-Degrade 103
+VALUE USR-Event-Id RADIUS-Accounting-Group-NonOper 104
+VALUE USR-Event-Id T1/T1-E1/PRI-InCall-Fail-Event 119
+VALUE USR-Event-Id T1/T1-E1/PRI-OutCall-Fail-Event 120
+VALUE USR-Event-Id RMMIE-Retrain-Event 121
+VALUE USR-Event-Id RMMIE-Speed-Shift-Event 122
+VALUE USR-Event-Id CDMA-Call-Start 191
+VALUE USR-Event-Id CDMA-Call-End 192
+
+VALUE USR-Card-Type SlotEmpty 1
+VALUE USR-Card-Type SlotUnknown 2
+VALUE USR-Card-Type NetwMgtCard 3
+VALUE USR-Card-Type DualT1NAC 4
+VALUE USR-Card-Type DualModemNAC 5
+VALUE USR-Card-Type QuadModemNAC 6
+VALUE USR-Card-Type TrGatewayNAC 7
+VALUE USR-Card-Type X25GatewayNAC 8
+VALUE USR-Card-Type DualV34ModemNAC 9
+VALUE USR-Card-Type QuadV32DigitalModemNAC 10
+VALUE USR-Card-Type QuadV32AnalogModemNAC 11
+VALUE USR-Card-Type QuadV32DigAnlModemNAC 12
+VALUE USR-Card-Type QuadV34DigModemNAC 13
+VALUE USR-Card-Type QuadV34AnlModemNAC 14
+VALUE USR-Card-Type QuadV34DigAnlModemNAC 15
+VALUE USR-Card-Type SingleT1NAC 16
+VALUE USR-Card-Type EthernetGatewayNAC 17
+VALUE USR-Card-Type AccessServer 18
+VALUE USR-Card-Type 486TrGatewayNAC 19
+VALUE USR-Card-Type 486EthernetGatewayNAC 20
+VALUE USR-Card-Type DualRS232NAC 22
+VALUE USR-Card-Type 486X25GatewayNAC 23
+VALUE USR-Card-Type ApplicationServerNAC 25
+VALUE USR-Card-Type ISDNGatewayNAC 26
+VALUE USR-Card-Type ISDNpriT1NAC 27
+VALUE USR-Card-Type ClkedNetMgtCard 28
+VALUE USR-Card-Type ModemPoolManagementNAC 29
+VALUE USR-Card-Type ModemPoolNetserverNAC 30
+VALUE USR-Card-Type ModemPoolV34ModemNAC 31
+VALUE USR-Card-Type ModemPoolISDNNAC 32
+VALUE USR-Card-Type NTServerNAC 33
+VALUE USR-Card-Type QuadV34DigitalG2NAC 34
+VALUE USR-Card-Type QuadV34AnalogG2NAC 35
+VALUE USR-Card-Type QuadV34DigAnlgG2NAC 36
+VALUE USR-Card-Type NETServerFrameRelayNAC 37
+VALUE USR-Card-Type NETServerTokenRingNAC 38
+VALUE USR-Card-Type X2524ChannelNAC 39
+VALUE USR-Card-Type WirelessGatewayNac 42
+
+VALUE USR-Card-Type EnhancedAccessServer 44
+VALUE USR-Card-Type EnhancedISDNGatewayNAC 45
+
+VALUE USR-Card-Type DualT1NIC 1001
+VALUE USR-Card-Type DualAlogMdmNIC 1002
+VALUE USR-Card-Type QuadDgtlMdmNIC 1003
+VALUE USR-Card-Type QuadAlogDgtlMdmNIC 1004
+VALUE USR-Card-Type TokenRingNIC 1005
+VALUE USR-Card-Type SingleT1NIC 1006
+VALUE USR-Card-Type EthernetNIC 1007
+VALUE USR-Card-Type ShortHaulDualT1NIC 1008
+VALUE USR-Card-Type DualAlogMgdIntlMdmNIC 1009
+VALUE USR-Card-Type X25NIC 1010
+VALUE USR-Card-Type QuadAlogNonMgdMdmNIC 1011
+VALUE USR-Card-Type QuadAlogMgdIntlMdmNIC 1012
+VALUE USR-Card-Type QuadAlogNonMgdIntlMdmNIC 1013
+VALUE USR-Card-Type QuadLsdLiMgdMdmNIC 1014
+VALUE USR-Card-Type QuadLsdLiNonMgdMdmNIC 1015
+VALUE USR-Card-Type QuadLsdLiMgdIntlMdmNIC 1016
+VALUE USR-Card-Type QuadLsdLiNonMgdIntlMdmNIC 1017
+VALUE USR-Card-Type HSEthernetWithV35NIC 1018
+VALUE USR-Card-Type HSEthernetWithoutV35NIC 1019
+VALUE USR-Card-Type DualHighSpeedV35NIC 1020
+VALUE USR-Card-Type QuadV35RS232LowSpeedNIC 1021
+VALUE USR-Card-Type DualE1NIC 1022
+VALUE USR-Card-Type ShortHaulDualE1NIC 1023
+VALUE USR-Card-Type BellcoreLongHaulDualT1NIC 1025
+VALUE USR-Card-Type BellcoreShrtHaulDualT1NIC 1026
+VALUE USR-Card-Type SCSIEdgeServerNIC 1027
+
+VALUE USR-Default-DTE-Data-Rate 110-BPS 1
+VALUE USR-Default-DTE-Data-Rate 300-BPS 2
+VALUE USR-Default-DTE-Data-Rate 600-BPS 3
+VALUE USR-Default-DTE-Data-Rate 1200-BPS 4
+VALUE USR-Default-DTE-Data-Rate 2400-BPS 5
+VALUE USR-Default-DTE-Data-Rate 4800-BPS 6
+VALUE USR-Default-DTE-Data-Rate 7200-BPS 7
+VALUE USR-Default-DTE-Data-Rate 9600-BPS 8
+VALUE USR-Default-DTE-Data-Rate 12K-BPS 9
+VALUE USR-Default-DTE-Data-Rate 14.4K-BPS 10
+VALUE USR-Default-DTE-Data-Rate 16.8-BPS 11
+VALUE USR-Default-DTE-Data-Rate 19.2K-BPS 12
+VALUE USR-Default-DTE-Data-Rate 38.4K-BPS 13
+VALUE USR-Default-DTE-Data-Rate 75-BPS 14
+VALUE USR-Default-DTE-Data-Rate 450-BPS 15
+VALUE USR-Default-DTE-Data-Rate UNKNOWN-BPS 16
+VALUE USR-Default-DTE-Data-Rate 57.6K-BPS 17
+VALUE USR-Default-DTE-Data-Rate 21.6K-BPS 18
+VALUE USR-Default-DTE-Data-Rate 24K-BPS 19
+VALUE USR-Default-DTE-Data-Rate 26K-BPS 20
+VALUE USR-Default-DTE-Data-Rate 28K-BPS 21
+VALUE USR-Default-DTE-Data-Rate 115K-BPS 22
+
+VALUE USR-Initial-Rx-Link-Data-Rate 110-BPS 1
+VALUE USR-Initial-Rx-Link-Data-Rate 300-BPS 2
+VALUE USR-Initial-Rx-Link-Data-Rate 600-BPS 3
+VALUE USR-Initial-Rx-Link-Data-Rate 1200-BPS 4
+VALUE USR-Initial-Rx-Link-Data-Rate 2400-BPS 5
+VALUE USR-Initial-Rx-Link-Data-Rate 4800-BPS 6
+VALUE USR-Initial-Rx-Link-Data-Rate 7200-BPS 7
+VALUE USR-Initial-Rx-Link-Data-Rate 9600-BPS 8
+VALUE USR-Initial-Rx-Link-Data-Rate 12000-BPS 9
+VALUE USR-Initial-Rx-Link-Data-Rate 14400-BPS 10
+VALUE USR-Initial-Rx-Link-Data-Rate 16800-BPS 11
+VALUE USR-Initial-Rx-Link-Data-Rate 19200-BPS 12
+VALUE USR-Initial-Rx-Link-Data-Rate 38400-BPS 13
+VALUE USR-Initial-Rx-Link-Data-Rate 75-BPS 14
+VALUE USR-Initial-Rx-Link-Data-Rate 450-BPS 15
+VALUE USR-Initial-Rx-Link-Data-Rate UNKNOWN-BPS 16
+VALUE USR-Initial-Rx-Link-Data-Rate 57600-BPS 17
+VALUE USR-Initial-Rx-Link-Data-Rate 21600-BPS 18
+VALUE USR-Initial-Rx-Link-Data-Rate 24000-BPS 19
+VALUE USR-Initial-Rx-Link-Data-Rate 26400-BPS 20
+VALUE USR-Initial-Rx-Link-Data-Rate 28800-BPS 21
+VALUE USR-Initial-Rx-Link-Data-Rate 115200-BPS 22
+VALUE USR-Initial-Rx-Link-Data-Rate 31200-BPS 23
+VALUE USR-Initial-Rx-Link-Data-Rate 33600-BPS 24
+VALUE USR-Initial-Rx-Link-Data-Rate 25333-BPS 25
+VALUE USR-Initial-Rx-Link-Data-Rate 26666-BPS 26
+VALUE USR-Initial-Rx-Link-Data-Rate 28000-BPS 27
+VALUE USR-Initial-Rx-Link-Data-Rate 29333-BPS 28
+VALUE USR-Initial-Rx-Link-Data-Rate 30666-BPS 29
+VALUE USR-Initial-Rx-Link-Data-Rate 32000-BPS 30
+VALUE USR-Initial-Rx-Link-Data-Rate 33333-BPS 31
+VALUE USR-Initial-Rx-Link-Data-Rate 34666-BPS 32
+VALUE USR-Initial-Rx-Link-Data-Rate 36000-BPS 33
+VALUE USR-Initial-Rx-Link-Data-Rate 37333-BPS 34
+VALUE USR-Initial-Rx-Link-Data-Rate 38666-BPS 35
+VALUE USR-Initial-Rx-Link-Data-Rate 40000-BPS 36
+VALUE USR-Initial-Rx-Link-Data-Rate 41333-BPS 37
+VALUE USR-Initial-Rx-Link-Data-Rate 42666-BPS 38
+VALUE USR-Initial-Rx-Link-Data-Rate 44000-BPS 39
+VALUE USR-Initial-Rx-Link-Data-Rate 45333-BPS 40
+VALUE USR-Initial-Rx-Link-Data-Rate 46666-BPS 41
+VALUE USR-Initial-Rx-Link-Data-Rate 48000-BPS 42
+VALUE USR-Initial-Rx-Link-Data-Rate 49333-BPS 43
+VALUE USR-Initial-Rx-Link-Data-Rate 50666-BPS 44
+VALUE USR-Initial-Rx-Link-Data-Rate 52000-BPS 45
+VALUE USR-Initial-Rx-Link-Data-Rate 53333-BPS 46
+VALUE USR-Initial-Rx-Link-Data-Rate 54666-BPS 47
+VALUE USR-Initial-Rx-Link-Data-Rate 56000-BPS 48
+VALUE USR-Initial-Rx-Link-Data-Rate 57333-BPS 49
+VALUE USR-Initial-Rx-Link-Data-Rate 58666-BPS 50
+VALUE USR-Initial-Rx-Link-Data-Rate 60000-BPS 51
+VALUE USR-Initial-Rx-Link-Data-Rate 61333-BPS 52
+VALUE USR-Initial-Rx-Link-Data-Rate 62666-BPS 53
+VALUE USR-Initial-Rx-Link-Data-Rate 64000-BPS 54
+
+VALUE USR-Final-Rx-Link-Data-Rate 110-BPS 1
+VALUE USR-Final-Rx-Link-Data-Rate 300-BPS 2
+VALUE USR-Final-Rx-Link-Data-Rate 600-BPS 3
+VALUE USR-Final-Rx-Link-Data-Rate 1200-BPS 4
+VALUE USR-Final-Rx-Link-Data-Rate 2400-BPS 5
+VALUE USR-Final-Rx-Link-Data-Rate 4800-BPS 6
+VALUE USR-Final-Rx-Link-Data-Rate 7200-BPS 7
+VALUE USR-Final-Rx-Link-Data-Rate 9600-BPS 8
+VALUE USR-Final-Rx-Link-Data-Rate 12000-BPS 9
+VALUE USR-Final-Rx-Link-Data-Rate 14400-BPS 10
+VALUE USR-Final-Rx-Link-Data-Rate 16800-BPS 11
+VALUE USR-Final-Rx-Link-Data-Rate 19200-BPS 12
+VALUE USR-Final-Rx-Link-Data-Rate 38400-BPS 13
+VALUE USR-Final-Rx-Link-Data-Rate 75-BPS 14
+VALUE USR-Final-Rx-Link-Data-Rate 450-BPS 15
+VALUE USR-Final-Rx-Link-Data-Rate UNKNOWN-BPS 16
+VALUE USR-Final-Rx-Link-Data-Rate 57600-BPS 17
+VALUE USR-Final-Rx-Link-Data-Rate 21600-BPS 18
+VALUE USR-Final-Rx-Link-Data-Rate 24000-BPS 19
+VALUE USR-Final-Rx-Link-Data-Rate 26400-BPS 20
+VALUE USR-Final-Rx-Link-Data-Rate 28800-BPS 21
+VALUE USR-Final-Rx-Link-Data-Rate 115200-BPS 22
+VALUE USR-Final-Rx-Link-Data-Rate 31200-BPS 23
+VALUE USR-Final-Rx-Link-Data-Rate 33600-BPS 24
+VALUE USR-Final-Rx-Link-Data-Rate 25333-BPS 25
+VALUE USR-Final-Rx-Link-Data-Rate 26666-BPS 26
+VALUE USR-Final-Rx-Link-Data-Rate 28000-BPS 27
+VALUE USR-Final-Rx-Link-Data-Rate 29333-BPS 28
+VALUE USR-Final-Rx-Link-Data-Rate 30666-BPS 29
+VALUE USR-Final-Rx-Link-Data-Rate 32000-BPS 30
+VALUE USR-Final-Rx-Link-Data-Rate 33333-BPS 31
+VALUE USR-Final-Rx-Link-Data-Rate 34666-BPS 32
+VALUE USR-Final-Rx-Link-Data-Rate 36000-BPS 33
+VALUE USR-Final-Rx-Link-Data-Rate 37333-BPS 34
+VALUE USR-Final-Rx-Link-Data-Rate 38666-BPS 35
+VALUE USR-Final-Rx-Link-Data-Rate 40000-BPS 36
+VALUE USR-Final-Rx-Link-Data-Rate 41333-BPS 37
+VALUE USR-Final-Rx-Link-Data-Rate 42666-BPS 38
+VALUE USR-Final-Rx-Link-Data-Rate 44000-BPS 39
+VALUE USR-Final-Rx-Link-Data-Rate 45333-BPS 40
+VALUE USR-Final-Rx-Link-Data-Rate 46666-BPS 41
+VALUE USR-Final-Rx-Link-Data-Rate 48000-BPS 42
+VALUE USR-Final-Rx-Link-Data-Rate 49333-BPS 43
+VALUE USR-Final-Rx-Link-Data-Rate 50666-BPS 44
+VALUE USR-Final-Rx-Link-Data-Rate 52000-BPS 45
+VALUE USR-Final-Rx-Link-Data-Rate 53333-BPS 46
+VALUE USR-Final-Rx-Link-Data-Rate 54666-BPS 47
+VALUE USR-Final-Rx-Link-Data-Rate 56000-BPS 48
+VALUE USR-Final-Rx-Link-Data-Rate 57333-BPS 49
+VALUE USR-Final-Rx-Link-Data-Rate 58666-BPS 50
+VALUE USR-Final-Rx-Link-Data-Rate 60000-BPS 51
+VALUE USR-Final-Rx-Link-Data-Rate 61333-BPS 52
+VALUE USR-Final-Rx-Link-Data-Rate 62666-BPS 53
+VALUE USR-Final-Rx-Link-Data-Rate 64000-BPS 54
+
+VALUE USR-Initial-Tx-Link-Data-Rate 110-BPS 1
+VALUE USR-Initial-Tx-Link-Data-Rate 300-BPS 2
+VALUE USR-Initial-Tx-Link-Data-Rate 600-BPS 3
+VALUE USR-Initial-Tx-Link-Data-Rate 1200-BPS 4
+VALUE USR-Initial-Tx-Link-Data-Rate 2400-BPS 5
+VALUE USR-Initial-Tx-Link-Data-Rate 4800-BPS 6
+VALUE USR-Initial-Tx-Link-Data-Rate 7200-BPS 7
+VALUE USR-Initial-Tx-Link-Data-Rate 9600-BPS 8
+VALUE USR-Initial-Tx-Link-Data-Rate 12000-BPS 9
+VALUE USR-Initial-Tx-Link-Data-Rate 14400-BPS 10
+VALUE USR-Initial-Tx-Link-Data-Rate 16800-BPS 11
+VALUE USR-Initial-Tx-Link-Data-Rate 19200-BPS 12
+VALUE USR-Initial-Tx-Link-Data-Rate 38400-BPS 13
+VALUE USR-Initial-Tx-Link-Data-Rate 75-BPS 14
+VALUE USR-Initial-Tx-Link-Data-Rate 450-BPS 15
+VALUE USR-Initial-Tx-Link-Data-Rate UNKNOWN-BPS 16
+VALUE USR-Initial-Tx-Link-Data-Rate 57600-BPS 17
+VALUE USR-Initial-Tx-Link-Data-Rate 21600-BPS 18
+VALUE USR-Initial-Tx-Link-Data-Rate 24000-BPS 19
+VALUE USR-Initial-Tx-Link-Data-Rate 26400-BPS 20
+VALUE USR-Initial-Tx-Link-Data-Rate 28800-BPS 21
+VALUE USR-Initial-Tx-Link-Data-Rate 115200-BPS 22
+VALUE USR-Initial-Tx-Link-Data-Rate 31200-BPS 23
+VALUE USR-Initial-Tx-Link-Data-Rate 33600-BPS 24
+VALUE USR-Initial-Tx-Link-Data-Rate 25333-BPS 25
+VALUE USR-Initial-Tx-Link-Data-Rate 26666-BPS 26
+VALUE USR-Initial-Tx-Link-Data-Rate 28000-BPS 27
+VALUE USR-Initial-Tx-Link-Data-Rate 29333-BPS 28
+VALUE USR-Initial-Tx-Link-Data-Rate 30666-BPS 29
+VALUE USR-Initial-Tx-Link-Data-Rate 32000-BPS 30
+VALUE USR-Initial-Tx-Link-Data-Rate 33333-BPS 31
+VALUE USR-Initial-Tx-Link-Data-Rate 34666-BPS 32
+VALUE USR-Initial-Tx-Link-Data-Rate 36000-BPS 33
+VALUE USR-Initial-Tx-Link-Data-Rate 37333-BPS 34
+VALUE USR-Initial-Tx-Link-Data-Rate 38666-BPS 35
+VALUE USR-Initial-Tx-Link-Data-Rate 40000-BPS 36
+VALUE USR-Initial-Tx-Link-Data-Rate 41333-BPS 37
+VALUE USR-Initial-Tx-Link-Data-Rate 42666-BPS 38
+VALUE USR-Initial-Tx-Link-Data-Rate 44000-BPS 39
+VALUE USR-Initial-Tx-Link-Data-Rate 45333-BPS 40
+VALUE USR-Initial-Tx-Link-Data-Rate 46666-BPS 41
+VALUE USR-Initial-Tx-Link-Data-Rate 48000-BPS 42
+VALUE USR-Initial-Tx-Link-Data-Rate 49333-BPS 43
+VALUE USR-Initial-Tx-Link-Data-Rate 50666-BPS 44
+VALUE USR-Initial-Tx-Link-Data-Rate 52000-BPS 45
+VALUE USR-Initial-Tx-Link-Data-Rate 53333-BPS 46
+VALUE USR-Initial-Tx-Link-Data-Rate 54666-BPS 47
+VALUE USR-Initial-Tx-Link-Data-Rate 56000-BPS 48
+VALUE USR-Initial-Tx-Link-Data-Rate 57333-BPS 49
+VALUE USR-Initial-Tx-Link-Data-Rate 58666-BPS 50
+VALUE USR-Initial-Tx-Link-Data-Rate 60000-BPS 51
+VALUE USR-Initial-Tx-Link-Data-Rate 61333-BPS 52
+VALUE USR-Initial-Tx-Link-Data-Rate 62666-BPS 53
+VALUE USR-Initial-Tx-Link-Data-Rate 64000-BPS 54
+
+VALUE USR-Final-Tx-Link-Data-Rate 110-BPS 1
+VALUE USR-Final-Tx-Link-Data-Rate 300-BPS 2
+VALUE USR-Final-Tx-Link-Data-Rate 600-BPS 3
+VALUE USR-Final-Tx-Link-Data-Rate 1200-BPS 4
+VALUE USR-Final-Tx-Link-Data-Rate 2400-BPS 5
+VALUE USR-Final-Tx-Link-Data-Rate 4800-BPS 6
+VALUE USR-Final-Tx-Link-Data-Rate 7200-BPS 7
+VALUE USR-Final-Tx-Link-Data-Rate 9600-BPS 8
+VALUE USR-Final-Tx-Link-Data-Rate 12000-BPS 9
+VALUE USR-Final-Tx-Link-Data-Rate 14400-BPS 10
+VALUE USR-Final-Tx-Link-Data-Rate 16800-BPS 11
+VALUE USR-Final-Tx-Link-Data-Rate 19200-BPS 12
+VALUE USR-Final-Tx-Link-Data-Rate 38400-BPS 13
+VALUE USR-Final-Tx-Link-Data-Rate 75-BPS 14
+VALUE USR-Final-Tx-Link-Data-Rate 450-BPS 15
+VALUE USR-Final-Tx-Link-Data-Rate UNKNOWN-BPS 16
+VALUE USR-Final-Tx-Link-Data-Rate 57600-BPS 17
+VALUE USR-Final-Tx-Link-Data-Rate 21600-BPS 18
+VALUE USR-Final-Tx-Link-Data-Rate 24000-BPS 19
+VALUE USR-Final-Tx-Link-Data-Rate 26400-BPS 20
+VALUE USR-Final-Tx-Link-Data-Rate 28800-BPS 21
+VALUE USR-Final-Tx-Link-Data-Rate 115200-BPS 22
+VALUE USR-Final-Tx-Link-Data-Rate 31200-BPS 23
+VALUE USR-Final-Tx-Link-Data-Rate 33600-BPS 24
+VALUE USR-Final-Tx-Link-Data-Rate 25333-BPS 25
+VALUE USR-Final-Tx-Link-Data-Rate 26666-BPS 26
+VALUE USR-Final-Tx-Link-Data-Rate 28000-BPS 27
+VALUE USR-Final-Tx-Link-Data-Rate 29333-BPS 28
+VALUE USR-Final-Tx-Link-Data-Rate 30666-BPS 29
+VALUE USR-Final-Tx-Link-Data-Rate 32000-BPS 30
+VALUE USR-Final-Tx-Link-Data-Rate 33333-BPS 31
+VALUE USR-Final-Tx-Link-Data-Rate 34666-BPS 32
+VALUE USR-Final-Tx-Link-Data-Rate 36000-BPS 33
+VALUE USR-Final-Tx-Link-Data-Rate 37333-BPS 34
+VALUE USR-Final-Tx-Link-Data-Rate 38666-BPS 35
+VALUE USR-Final-Tx-Link-Data-Rate 40000-BPS 36
+VALUE USR-Final-Tx-Link-Data-Rate 41333-BPS 37
+VALUE USR-Final-Tx-Link-Data-Rate 42666-BPS 38
+VALUE USR-Final-Tx-Link-Data-Rate 44000-BPS 39
+VALUE USR-Final-Tx-Link-Data-Rate 45333-BPS 40
+VALUE USR-Final-Tx-Link-Data-Rate 46666-BPS 41
+VALUE USR-Final-Tx-Link-Data-Rate 48000-BPS 42
+VALUE USR-Final-Tx-Link-Data-Rate 49333-BPS 43
+VALUE USR-Final-Tx-Link-Data-Rate 50666-BPS 44
+VALUE USR-Final-Tx-Link-Data-Rate 52000-BPS 45
+VALUE USR-Final-Tx-Link-Data-Rate 53333-BPS 46
+VALUE USR-Final-Tx-Link-Data-Rate 54666-BPS 47
+VALUE USR-Final-Tx-Link-Data-Rate 56000-BPS 48
+VALUE USR-Final-Tx-Link-Data-Rate 57333-BPS 49
+VALUE USR-Final-Tx-Link-Data-Rate 58666-BPS 50
+VALUE USR-Final-Tx-Link-Data-Rate 60000-BPS 51
+VALUE USR-Final-Tx-Link-Data-Rate 61333-BPS 52
+VALUE USR-Final-Tx-Link-Data-Rate 62666-BPS 53
+VALUE USR-Final-Tx-Link-Data-Rate 64000-BPS 54
+
+VALUE USR-Connect-Speed NONE 1
+VALUE USR-Connect-Speed 300-BPS 2
+VALUE USR-Connect-Speed 1200-BPS 3
+VALUE USR-Connect-Speed 2400-BPS 4
+VALUE USR-Connect-Speed 4800-BPS 5
+VALUE USR-Connect-Speed 7200-BPS 6
+VALUE USR-Connect-Speed 9600-BPS 7
+VALUE USR-Connect-Speed 12000-BPS 8
+VALUE USR-Connect-Speed 14400-BPS 9
+VALUE USR-Connect-Speed 16800-BPS 10
+VALUE USR-Connect-Speed 19200-BPS 11
+VALUE USR-Connect-Speed 21600-BPS 12
+VALUE USR-Connect-Speed 28800-BPS 13
+VALUE USR-Connect-Speed 38400-BPS 14
+VALUE USR-Connect-Speed 57600-BPS 15
+VALUE USR-Connect-Speed 115200-BPS 16
+VALUE USR-Connect-Speed 288000-BPS 17
+VALUE USR-Connect-Speed 75-1200-BPS 18
+VALUE USR-Connect-Speed 1200-75-BPS 19
+VALUE USR-Connect-Speed 24000-BPS 20
+VALUE USR-Connect-Speed 26400-BPS 21
+VALUE USR-Connect-Speed 31200-BPS 22
+VALUE USR-Connect-Speed 33600-BPS 23
+VALUE USR-Connect-Speed 33333-BPS 24
+VALUE USR-Connect-Speed 37333-BPS 25
+VALUE USR-Connect-Speed 41333-BPS 26
+VALUE USR-Connect-Speed 42666-BPS 27
+VALUE USR-Connect-Speed 44000-BPS 28
+VALUE USR-Connect-Speed 45333-BPS 29
+VALUE USR-Connect-Speed 46666-BPS 30
+VALUE USR-Connect-Speed 48000-BPS 31
+VALUE USR-Connect-Speed 49333-BPS 32
+VALUE USR-Connect-Speed 50666-BPS 33
+VALUE USR-Connect-Speed 52000-BPS 34
+VALUE USR-Connect-Speed 53333-BPS 35
+VALUE USR-Connect-Speed 54666-BPS 36
+VALUE USR-Connect-Speed 56000-BPS 37
+VALUE USR-Connect-Speed 57333-BPS 38
+VALUE USR-Connect-Speed 64000-BPS 39
+VALUE USR-Connect-Speed 25333-BPS 40
+VALUE USR-Connect-Speed 26666-BPS 41
+VALUE USR-Connect-Speed 28000-BPS 42
+VALUE USR-Connect-Speed 29333-BPS 43
+VALUE USR-Connect-Speed 30666-BPS 44
+VALUE USR-Connect-Speed 32000-BPS 45
+VALUE USR-Connect-Speed 34666-BPS 46
+VALUE USR-Connect-Speed 36000-BPS 47
+VALUE USR-Connect-Speed 38666-BPS 48
+VALUE USR-Connect-Speed 40000-BPS 49
+VALUE USR-Connect-Speed 58666-BPS 50
+VALUE USR-Connect-Speed 60000-BPS 51
+VALUE USR-Connect-Speed 61333-BPS 52
+VALUE USR-Connect-Speed 62666-BPS 53
+
+VALUE USR-Sync-Async-Mode Asynchronous 1
+VALUE USR-Sync-Async-Mode Synchronous 2
+
+VALUE USR-Originate-Answer-Mode Originate_in_Originate_Mode 1
+VALUE USR-Originate-Answer-Mode Originate_in_Answer_Mode 2
+VALUE USR-Originate-Answer-Mode Answer_in_Originate_Mode 3
+VALUE USR-Originate-Answer-Mode Answer_in_Answer_Mode 4
+
+VALUE USR-Modulation-Type usRoboticsHST 1
+VALUE USR-Modulation-Type ccittV32 2
+VALUE USR-Modulation-Type ccittV22bis 3
+VALUE USR-Modulation-Type bell103 4
+VALUE USR-Modulation-Type ccittV21 5
+VALUE USR-Modulation-Type bell212 6
+VALUE USR-Modulation-Type ccittV32bis 7
+VALUE USR-Modulation-Type ccittV23 8
+VALUE USR-Modulation-Type negotiationFailed 9
+VALUE USR-Modulation-Type bell208b 10
+VALUE USR-Modulation-Type v21FaxClass1 11
+VALUE USR-Modulation-Type v27FaxClass1 12
+VALUE USR-Modulation-Type v29FaxClass1 13
+VALUE USR-Modulation-Type v17FaxClass1 14
+VALUE USR-Modulation-Type v21FaxClass2 15
+VALUE USR-Modulation-Type v27FaxClass2 16
+VALUE USR-Modulation-Type v29FaxClass2 17
+VALUE USR-Modulation-Type v17FaxClass2 18
+VALUE USR-Modulation-Type v32Terbo 19
+VALUE USR-Modulation-Type v34 20
+VALUE USR-Modulation-Type vFC 21
+VALUE USR-Modulation-Type v34plus 22
+VALUE USR-Modulation-Type x2 23
+VALUE USR-Modulation-Type v110 24
+VALUE USR-Modulation-Type v120 25
+VALUE USR-Modulation-Type x75 26
+VALUE USR-Modulation-Type asyncSyncPPP 27
+VALUE USR-Modulation-Type clearChannel 28
+VALUE USR-Modulation-Type x2client 29
+VALUE USR-Modulation-Type x2symmetric 30
+VALUE USR-Modulation-Type piafs 31
+VALUE USR-Modulation-Type x2version2 32
+VALUE USR-Modulation-Type v90Analog 33
+VALUE USR-Modulation-Type v90Digital 34
+VALUE USR-Modulation-Type v90AllDigital 35
+
+VALUE Initial-Modulation-Type usRoboticsHST 1
+VALUE Initial-Modulation-Type ccittV32 2
+VALUE Initial-Modulation-Type ccittV22bis 3
+VALUE Initial-Modulation-Type bell103 4
+VALUE Initial-Modulation-Type ccittV21 5
+VALUE Initial-Modulation-Type bell212 6
+VALUE Initial-Modulation-Type ccittV32bis 7
+VALUE Initial-Modulation-Type ccittV23 8
+VALUE Initial-Modulation-Type negotiationFailed 9
+VALUE Initial-Modulation-Type bell208b 10
+VALUE Initial-Modulation-Type v21FaxClass1 11
+VALUE Initial-Modulation-Type v27FaxClass1 12
+VALUE Initial-Modulation-Type v29FaxClass1 13
+VALUE Initial-Modulation-Type v17FaxClass1 14
+VALUE Initial-Modulation-Type v21FaxClass2 15
+VALUE Initial-Modulation-Type v27FaxClass2 16
+VALUE Initial-Modulation-Type v29FaxClass2 17
+VALUE Initial-Modulation-Type v17FaxClass2 18
+VALUE Initial-Modulation-Type v32Terbo 19
+VALUE Initial-Modulation-Type v34 20
+VALUE Initial-Modulation-Type vFC 21
+VALUE Initial-Modulation-Type v34plus 22
+VALUE Initial-Modulation-Type x2 23
+VALUE Initial-Modulation-Type v110 24
+VALUE Initial-Modulation-Type v120 25
+VALUE Initial-Modulation-Type x75 26
+VALUE Initial-Modulation-Type asyncSyncPPP 27
+VALUE Initial-Modulation-Type clearChannel 28
+VALUE Initial-Modulation-Type x2client 29
+VALUE Initial-Modulation-Type x2symmetric 30
+VALUE Initial-Modulation-Type piafs 31
+VALUE Initial-Modulation-Type x2version2 32
+VALUE Initial-Modulation-Type v90Analogue 33
+VALUE Initial-Modulation-Type v90Digital 34
+VALUE Initial-Modulation-Type v90AllDigital 35
+
+VALUE USR-Connect-Term-Reason dtrDrop 1
+VALUE USR-Connect-Term-Reason escapeSequence 2
+VALUE USR-Connect-Term-Reason athCommand 3
+VALUE USR-Connect-Term-Reason carrierLoss 4
+VALUE USR-Connect-Term-Reason inactivityTimout 5
+VALUE USR-Connect-Term-Reason mnpIncompatible 6
+VALUE USR-Connect-Term-Reason undefined 7
+VALUE USR-Connect-Term-Reason remotePassword 8
+VALUE USR-Connect-Term-Reason linkPassword 9
+VALUE USR-Connect-Term-Reason retransmitLimit 10
+VALUE USR-Connect-Term-Reason linkDisconnectMsgReceived 11
+VALUE USR-Connect-Term-Reason noLoopCurrent 12
+VALUE USR-Connect-Term-Reason invalidSpeed 13
+VALUE USR-Connect-Term-Reason unableToRetrain 14
+VALUE USR-Connect-Term-Reason managementCommand 15
+VALUE USR-Connect-Term-Reason noDialTone 16
+VALUE USR-Connect-Term-Reason keyAbort 17
+VALUE USR-Connect-Term-Reason lineBusy 18
+VALUE USR-Connect-Term-Reason noAnswer 19
+VALUE USR-Connect-Term-Reason voice 20
+VALUE USR-Connect-Term-Reason noAnswerTone 21
+VALUE USR-Connect-Term-Reason noCarrier 22
+VALUE USR-Connect-Term-Reason undetermined 23
+VALUE USR-Connect-Term-Reason v42SabmeTimeout 24
+VALUE USR-Connect-Term-Reason v42BreakTimeout 25
+VALUE USR-Connect-Term-Reason v42DisconnectCmd 26
+VALUE USR-Connect-Term-Reason v42IdExchangeFail 27
+VALUE USR-Connect-Term-Reason v42BadSetup 28
+VALUE USR-Connect-Term-Reason v42InvalidCodeWord 29
+VALUE USR-Connect-Term-Reason v42StringToLong 30
+VALUE USR-Connect-Term-Reason v42InvalidCommand 31
+VALUE USR-Connect-Term-Reason none 32
+VALUE USR-Connect-Term-Reason v32Cleardown 33
+VALUE USR-Connect-Term-Reason dialSecurity 34
+VALUE USR-Connect-Term-Reason remoteAccessDenied 35
+VALUE USR-Connect-Term-Reason loopLoss 36
+VALUE USR-Connect-Term-Reason ds0Teardown 37
+VALUE USR-Connect-Term-Reason promptNotEnabled 38
+VALUE USR-Connect-Term-Reason noPromptingInSync 39
+VALUE USR-Connect-Term-Reason nonArqMode 40
+VALUE USR-Connect-Term-Reason modeIncompatible 41
+VALUE USR-Connect-Term-Reason noPromptInNonARQ 42
+VALUE USR-Connect-Term-Reason dialBackLink 43
+VALUE USR-Connect-Term-Reason linkAbort 44
+VALUE USR-Connect-Term-Reason autopassFailed 45
+VALUE USR-Connect-Term-Reason pbGenericError 46
+VALUE USR-Connect-Term-Reason pbLinkErrTxPreAck 47
+VALUE USR-Connect-Term-Reason pbLinkErrTxTardyACK 48
+VALUE USR-Connect-Term-Reason pbTransmitBusTimeout 49
+VALUE USR-Connect-Term-Reason pbReceiveBusTimeout 50
+VALUE USR-Connect-Term-Reason pbLinkErrTxTAL 51
+VALUE USR-Connect-Term-Reason pbLinkErrRxTAL 52
+VALUE USR-Connect-Term-Reason pbTransmitMasterTimeout 53
+VALUE USR-Connect-Term-Reason pbClockMissing 54
+VALUE USR-Connect-Term-Reason pbReceivedLsWhileLinkUp 55
+VALUE USR-Connect-Term-Reason pbOutOfSequenceFrame 56
+VALUE USR-Connect-Term-Reason pbBadFrame 57
+VALUE USR-Connect-Term-Reason pbAckWaitTimeout 58
+VALUE USR-Connect-Term-Reason pbReceivedAckSeqErr 59
+VALUE USR-Connect-Term-Reason pbReceiveOvrflwRNRFail 60
+VALUE USR-Connect-Term-Reason pbReceiveMsgBufOvrflw 61
+VALUE USR-Connect-Term-Reason rcvdGatewayDiscCmd 62
+VALUE USR-Connect-Term-Reason tokenPassingTimeout 63
+VALUE USR-Connect-Term-Reason dspInterruptTimeout 64
+VALUE USR-Connect-Term-Reason mnpProtocolViolation 65
+VALUE USR-Connect-Term-Reason class2FaxHangupCmd 66
+VALUE USR-Connect-Term-Reason hstSpeedSwitchTimeout 67
+VALUE USR-Connect-Term-Reason tooManyUnacked 68
+VALUE USR-Connect-Term-Reason timerExpired 69
+VALUE USR-Connect-Term-Reason t1Glare 70
+VALUE USR-Connect-Term-Reason priDialoutRqTimeout 71
+VALUE USR-Connect-Term-Reason abortAnlgDstOvrIsdn 72
+VALUE USR-Connect-Term-Reason normalUserCallClear 73
+VALUE USR-Connect-Term-Reason normalUnspecified 74
+VALUE USR-Connect-Term-Reason bearerIncompatibility 75
+VALUE USR-Connect-Term-Reason protocolErrorEvent 76
+VALUE USR-Connect-Term-Reason abnormalDisconnect 77
+VALUE USR-Connect-Term-Reason invalidCauseValue 78
+VALUE USR-Connect-Term-Reason resourceUnavailable 79
+VALUE USR-Connect-Term-Reason remoteHungUpDuringTraining 80
+VALUE USR-Connect-Term-Reason trainingTimeout 81
+VALUE USR-Connect-Term-Reason incomingModemNotAvailable 82
+VALUE USR-Connect-Term-Reason incomingInvalidBearerCap 83
+VALUE USR-Connect-Term-Reason incomingInvalidChannelID 84
+VALUE USR-Connect-Term-Reason incomingInvalidProgInd 85
+VALUE USR-Connect-Term-Reason incomingInvalidCallingPty 86
+VALUE USR-Connect-Term-Reason incomingInvalidCalledPty 87
+VALUE USR-Connect-Term-Reason incomingCallBlock 88
+VALUE USR-Connect-Term-Reason incomingLoopStNoRingOff 89
+VALUE USR-Connect-Term-Reason outgoingTelcoDisconnect 90
+VALUE USR-Connect-Term-Reason outgoingEMWinkTimeout 91
+VALUE USR-Connect-Term-Reason outgoingEMWinkTooShort 92
+VALUE USR-Connect-Term-Reason outgoingNoChannelAvail 93
+VALUE USR-Connect-Term-Reason dspReboot 94
+VALUE USR-Connect-Term-Reason noDSPRespToKA 95
+VALUE USR-Connect-Term-Reason noDSPRespToDisc 96
+VALUE USR-Connect-Term-Reason dspTailPtrInvalid 97
+VALUE USR-Connect-Term-Reason dspHeadPtrInvalid 98
VALUE USR-Failure-to-Connect-Reason dtrDrop 1
VALUE USR-Failure-to-Connect-Reason escapeSequence 2
VALUE USR-Failure-to-Connect-Reason v42InvalidCodeWord 29
VALUE USR-Failure-to-Connect-Reason v42StringToLong 30
VALUE USR-Failure-to-Connect-Reason v42InvalidCommand 31
-VALUE USR-Failure-to-Connect-Reason none 32
+VALUE USR-Failure-to-Connect-Reason none 32
VALUE USR-Failure-to-Connect-Reason v32Cleardown 33
VALUE USR-Failure-to-Connect-Reason dialSecurity 34
VALUE USR-Failure-to-Connect-Reason remoteAccessDenied 35
VALUE USR-Failure-to-Connect-Reason pbReceiveBusTimeout 50
VALUE USR-Failure-to-Connect-Reason pbLinkErrTxTAL 51
VALUE USR-Failure-to-Connect-Reason pbLinkErrRxTAL 52
-VALUE USR-Failure-to-Connect-Reason pbTransmitMasterTimeout 53
+VALUE USR-Failure-to-Connect-Reason pbTransmitMasterTimeout 53
VALUE USR-Failure-to-Connect-Reason pbClockMissing 54
-VALUE USR-Failure-to-Connect-Reason pbReceivedLsWhileLinkUp 55
+VALUE USR-Failure-to-Connect-Reason pbReceivedLsWhileLinkUp 55
VALUE USR-Failure-to-Connect-Reason pbOutOfSequenceFrame 56
VALUE USR-Failure-to-Connect-Reason pbBadFrame 57
VALUE USR-Failure-to-Connect-Reason pbAckWaitTimeout 58
VALUE USR-Failure-to-Connect-Reason mnpProtocolViolation 65
VALUE USR-Failure-to-Connect-Reason class2FaxHangupCmd 66
VALUE USR-Failure-to-Connect-Reason hstSpeedSwitchTimeout 67
-VALUE USR-Failure-to-Connect-Reason tooManyUnacked 68
-VALUE USR-Failure-to-Connect-Reason timerExpired 69
-VALUE USR-Failure-to-Connect-Reason t1Glare 70
-VALUE USR-Failure-to-Connect-Reason priDialoutRqTimeout 71
-VALUE USR-Failure-to-Connect-Reason abortAnlgDstOvrIsdn 72
-VALUE USR-Failure-to-Connect-Reason normalUserCallClear 73
-VALUE USR-Failure-to-Connect-Reason normalUnspecified 74
-VALUE USR-Failure-to-Connect-Reason bearerIncompatibility 75
-VALUE USR-Failure-to-Connect-Reason protocolErrorEvent 76
-VALUE USR-Failure-to-Connect-Reason abnormalDisconnect 77
-VALUE USR-Failure-to-Connect-Reason invalidCauseValue 78
-VALUE USR-Failure-to-Connect-Reason resourceUnavailable 79
-VALUE USR-Failure-to-Connect-Reason remoteHungUpDuringTraining 80
-VALUE USR-Failure-to-Connect-Reason trainingTimeout 81
-VALUE USR-Failure-to-Connect-Reason incomingModemNotAvailable 82
-VALUE USR-Failure-to-Connect-Reason incomingInvalidBearerCap 83
-VALUE USR-Failure-to-Connect-Reason incomingInvalidChannelID 84
-VALUE USR-Failure-to-Connect-Reason incomingInvalidProgInd 85
-VALUE USR-Failure-to-Connect-Reason incomingInvalidCallingPty 86
-VALUE USR-Failure-to-Connect-Reason incomingInvalidCalledPty 87
-VALUE USR-Failure-to-Connect-Reason incomingCallBlock 88
-VALUE USR-Failure-to-Connect-Reason incomingLoopStNoRingOff 89
-VALUE USR-Failure-to-Connect-Reason outgoingTelcoDisconnect 90
-VALUE USR-Failure-to-Connect-Reason outgoingEMWinkTimeout 91
-VALUE USR-Failure-to-Connect-Reason outgoingEMWinkTooShort 92
-VALUE USR-Failure-to-Connect-Reason outgoingNoChannelAvail 93
-VALUE USR-Failure-to-Connect-Reason dspReboot 94
-VALUE USR-Failure-to-Connect-Reason noDSPRespToKA 95
-VALUE USR-Failure-to-Connect-Reason noDSPRespToDisc 96
-VALUE USR-Failure-to-Connect-Reason dspTailPtrInvalid 97
-VALUE USR-Failure-to-Connect-Reason dspHeadPtrInvalid 98
-
-VALUE USR-Simplified-MNP-Levels none 1
-VALUE USR-Simplified-MNP-Levels mnpLevel3 2
-VALUE USR-Simplified-MNP-Levels mnpLevel4 3
-VALUE USR-Simplified-MNP-Levels ccittV42 4
-VALUE USR-Simplified-MNP-Levels usRoboticsHST 5
-VALUE USR-Simplified-MNP-Levels synchronousNone 6
-VALUE USR-Simplified-MNP-Levels mnpLevel2 7
-VALUE USR-Simplified-MNP-Levels mnp10 8
-VALUE USR-Simplified-MNP-Levels v42Etc 9
-VALUE USR-Simplified-MNP-Levels mnp10Etc 10
-VALUE USR-Simplified-MNP-Levels lapmEtc 11
-VALUE USR-Simplified-MNP-Levels v42Etc2 12
-VALUE USR-Simplified-MNP-Levels v42SRej 13
-VALUE USR-Simplified-MNP-Levels piafs 14
-
-VALUE USR-Simplified-V42bis-Usage none 1
-VALUE USR-Simplified-V42bis-Usage ccittV42bis 2
-VALUE USR-Simplified-V42bis-Usage mnpLevel5 3
-
-VALUE USR-Equalization-Type Long 1
-VALUE USR-Equalization-Type Short 2
-
-
-VALUE USR-Fallback-Enabled Disabled 1
-VALUE USR-Fallback-Enabled Enabled 2
-
-
-VALUE USR-Back-Channel-Data-Rate 450BPS 1
-VALUE USR-Back-Channel-Data-Rate 300BPS 2
-VALUE USR-Back-Channel-Data-Rate None 3
-
-VALUE USR-Device-Connected-To None 1
-VALUE USR-Device-Connected-To isdnGateway 2
-VALUE USR-Device-Connected-To quadModem 3
-
-VALUE USR-Call-Event-Code notSupported 1
-VALUE USR-Call-Event-Code setup 2
-VALUE USR-Call-Event-Code usrSetup 3
-VALUE USR-Call-Event-Code telcoDisconnect 4
-VALUE USR-Call-Event-Code usrDisconnect 5
-VALUE USR-Call-Event-Code noFreeModem 6
-VALUE USR-Call-Event-Code modemsNotAllowed 7
-VALUE USR-Call-Event-Code modemsRejectCall 8
-VALUE USR-Call-Event-Code modemSetupTimeout 9
-VALUE USR-Call-Event-Code noFreeIGW 10
-VALUE USR-Call-Event-Code igwRejectCall 11
-VALUE USR-Call-Event-Code igwSetupTimeout 12
-VALUE USR-Call-Event-Code noFreeTdmts 13
-VALUE USR-Call-Event-Code bcReject 14
-VALUE USR-Call-Event-Code ieReject 15
-VALUE USR-Call-Event-Code chidReject 16
-VALUE USR-Call-Event-Code progReject 17
-VALUE USR-Call-Event-Code callingPartyReject 18
-VALUE USR-Call-Event-Code calledPartyReject 19
-VALUE USR-Call-Event-Code blocked 20
-VALUE USR-Call-Event-Code analogBlocked 21
-VALUE USR-Call-Event-Code digitalBlocked 22
-VALUE USR-Call-Event-Code outOfService 23
-VALUE USR-Call-Event-Code busy 24
-VALUE USR-Call-Event-Code congestion 25
-VALUE USR-Call-Event-Code protocolError 26
-VALUE USR-Call-Event-Code noFreeBchannel 27
-VALUE USR-Call-Event-Code inOutCallCollision 28
-VALUE USR-Call-Event-Code inCallArrival 29
-VALUE USR-Call-Event-Code outCallArrival 30
-VALUE USR-Call-Event-Code inCallConnect 31
-VALUE USR-Call-Event-Code outCallConnect 32
-
-VALUE USR-HARC-Disconnect-Code No-Error 0
-VALUE USR-HARC-Disconnect-Code No-Carrier 1
-VALUE USR-HARC-Disconnect-Code No-DSR 2
-VALUE USR-HARC-Disconnect-Code Timeout 3
-VALUE USR-HARC-Disconnect-Code Reset 4
-VALUE USR-HARC-Disconnect-Code Call-Drop-Req 5
-VALUE USR-HARC-Disconnect-Code Idle-Timeout 6
-VALUE USR-HARC-Disconnect-Code Session-Timeout 7
-VALUE USR-HARC-Disconnect-Code User-Req-Drop 8
-VALUE USR-HARC-Disconnect-Code Host-Req-Drop 9
-VALUE USR-HARC-Disconnect-Code Service-Interruption 10
-VALUE USR-HARC-Disconnect-Code Service-Unavailable 11
-VALUE USR-HARC-Disconnect-Code User-Input-Error 12
-VALUE USR-HARC-Disconnect-Code NAS-Drop-For-Callback 13
-VALUE USR-HARC-Disconnect-Code NAS-Drop-Misc-Non-Error 14
-VALUE USR-HARC-Disconnect-Code NAS-Internal-Error 15
-VALUE USR-HARC-Disconnect-Code Line-Busy 16
-VALUE USR-HARC-Disconnect-Code Tunnel-Term-Unreach 19
-VALUE USR-HARC-Disconnect-Code Tunnel-Refused 20
-VALUE USR-HARC-Disconnect-Code Tunnel-Auth-Failed 21
-VALUE USR-HARC-Disconnect-Code Tunnel-Session-Timeout 22
-VALUE USR-HARC-Disconnect-Code Tunnel-Timeout 23
-VALUE USR-HARC-Disconnect-Code Radius-Res-Reclaim 25
-VALUE USR-HARC-Disconnect-Code DNIS-Auth-Failed 26
-VALUE USR-HARC-Disconnect-Code PAP-Auth-Failure 27
-VALUE USR-HARC-Disconnect-Code CHAP-Auth-Failure 28
-VALUE USR-HARC-Disconnect-Code PPP-LCP-Failed 29
-VALUE USR-HARC-Disconnect-Code PPP-NCP-Failed 30
-VALUE USR-HARC-Disconnect-Code Radius-Timeout 31
-
-VALUE USR-CCP-Algorithm NONE 1
-VALUE USR-CCP-Algorithm Stac 2
-VALUE USR-CCP-Algorithm MS 3
-VALUE USR-CCP-Algorithm Any 4
-
-VALUE USR-Tunnel-Security None 0
-VALUE USR-Tunnel-Security Control-Only 1
-VALUE USR-Tunnel-Security Data-Only 2
-VALUE USR-Tunnel-Security Both-Data-and-Control 3
-
-VALUE USR-RMMIE-Status notEnabledInLocalModem 1
-VALUE USR-RMMIE-Status notDetectedInRemoteModem 2
-VALUE USR-RMMIE-Status ok 3
-
-VALUE USR-RMMIE-x2-Status notOperational 1
-VALUE USR-RMMIE-x2-Status operational 2
-VALUE USR-RMMIE-x2-Status x2Disabled 3
-VALUE USR-RMMIE-x2-Status v8Disabled 4
-VALUE USR-RMMIE-x2-Status remote3200Disabled 5
-VALUE USR-RMMIE-x2-Status invalidSpeedSetting 6
-VALUE USR-RMMIE-x2-Status v8NotDetected 7
-VALUE USR-RMMIE-x2-Status x2NotDetected 8
-VALUE USR-RMMIE-x2-Status incompatibleVersion 9
-VALUE USR-RMMIE-x2-Status incompatibleModes 10
-VALUE USR-RMMIE-x2-Status local3200Disabled 11
-VALUE USR-RMMIE-x2-Status excessHighFrequencyAtten 12
-VALUE USR-RMMIE-x2-Status connectNotSupport3200 13
-VALUE USR-RMMIE-x2-Status retrainBeforeConnection 14
-
-VALUE USR-RMMIE-Planned-Disconnect none 1
-VALUE USR-RMMIE-Planned-Disconnect dteNotReady 2
-VALUE USR-RMMIE-Planned-Disconnect dteInterfaceError 3
-VALUE USR-RMMIE-Planned-Disconnect dteRequest 4
-VALUE USR-RMMIE-Planned-Disconnect escapeToOnlineCommandMode 5
-VALUE USR-RMMIE-Planned-Disconnect athCommand 6
-VALUE USR-RMMIE-Planned-Disconnect inactivityTimeout 7
-VALUE USR-RMMIE-Planned-Disconnect arqProtocolError 8
-VALUE USR-RMMIE-Planned-Disconnect arqProtocolRetransmitLim 9
-VALUE USR-RMMIE-Planned-Disconnect invalidComprDataCodeword 10
-VALUE USR-RMMIE-Planned-Disconnect invalidComprDataStringLen 11
-VALUE USR-RMMIE-Planned-Disconnect invalidComprDataCommand 12
-
-VALUE USR-RMMIE-Last-Update-Event none 1
-VALUE USR-RMMIE-Last-Update-Event initialConnection 2
-VALUE USR-RMMIE-Last-Update-Event retrain 3
-VALUE USR-RMMIE-Last-Update-Event speedShift 4
-VALUE USR-RMMIE-Last-Update-Event plannedDisconnect 5
-
-VALUE USR-Request-Type Access-Request 1
-VALUE USR-Request-Type Access-Accept 2
-VALUE USR-Request-Type Access-Reject 3
-VALUE USR-Request-Type Accounting-Request 4
-VALUE USR-Request-Type Accounting-Response 5
-VALUE USR-Request-Type Access-Password-Change 7
-VALUE USR-Request-Type Access-Password-Ack 8
-VALUE USR-Request-Type Access-Password-Reject 9
-VALUE USR-Request-Type Access-Challenge 11
-VALUE USR-Request-Type Status-Server 12
-VALUE USR-Request-Type Status-Client 13
-VALUE USR-Request-Type Resource-Free-Request 21
-VALUE USR-Request-Type Resource-Free-Response 22
-VALUE USR-Request-Type Resource-Query-Request 23
-VALUE USR-Request-Type Resource-Query-Response 24
-VALUE USR-Request-Type Disconnect-User 25
-VALUE USR-Request-Type NAS-Reboot-Request 26
-VALUE USR-Request-Type NAS-Reboot-Response 27
-VALUE USR-Request-Type Tacacs-Message 253
-VALUE USR-Request-Type Reserved 255
-
-VALUE USR-PW_Framed_Routing_V2 Off 0
-VALUE USR-PW_Framed_Routing_V2 On 1
-
-VALUE USR-Syslog-Tap Off 0
-VALUE USR-Syslog-Tap Raw 1
-VALUE USR-Syslog-Tap Framed 2
-
-VALUE USR-Speed-Of-Connection Auto 0
-VALUE USR-Speed-Of-Connection 56 1
-VALUE USR-Speed-Of-Connection 64 2
-VALUE USR-Speed-Of-Connection Voice 3
-
-VALUE USR-Expansion-Algorithm Constant 1
-VALUE USR-Expansion-Algorithm Linear 2
-
-VALUE USR-Compression-Algorithm None 0
-VALUE USR-Compression-Algorithm Stac 1
-VALUE USR-Compression-Algorithm Ascend 2
-VALUE USR-Compression-Algorithm Microsoft 3
-VALUE USR-Compression-Algorithm Auto 4
-
-VALUE USR-Compression-Reset-Mode Auto 0
-VALUE USR-Compression-Reset-Mode Reset-Every-Packet 1
-VALUE USR-Compression-Reset-Mode Reset-On-Error 2
-
-VALUE USR-Filter-Zones enabled 1
-VALUE USR-Filter-Zones disabled 2
-
-VALUE USR-Bridging enabled 1
-VALUE USR-Bridging disabled 2
-
-VALUE USR-Appletalk enabled 1
-VALUE USR-Appletalk disabled 2
-
-VALUE USR-Spoofing enabled 1
-VALUE USR-Spoofing disabled 2
-
-VALUE USR-Routing-Protocol Rip1 1
-VALUE USR-Routing-Protocol Rip2 2
-
-VALUE USR-IPX-Routing none 0
-VALUE USR-IPX-Routing send 1
-VALUE USR-IPX-Routing listen 2
-VALUE USR-IPX-Routing respond 3
-VALUE USR-IPX-Routing all 4
-
-VALUE USR-IPX-WAN enabled 1
-VALUE USR-IPX-WAN disabled 2
-
-VALUE USR-IP-Default-Route-Option enabled 1
-VALUE USR-IP-Default-Route-Option disabled 2
-
-VALUE USR-IP-RIP-Policies SendDefault 0x0
-VALUE USR-IP-RIP-Policies SendRoutes 0x2
-VALUE USR-IP-RIP-Policies SendSubnets 0x4
-VALUE USR-IP-RIP-Policies AcceptDefault 0x8
-VALUE USR-IP-RIP-Policies SplitHorizon 0x10
-VALUE USR-IP-RIP-Policies PoisonReserve 0x20
-VALUE USR-IP-RIP-Policies FlashUpdate 0x40
-VALUE USR-IP-RIP-Policies SimpleAuth 0x80
-VALUE USR-IP-RIP-Policies V1Send 0x100
-VALUE USR-IP-RIP-Policies V1Receive 0x200
-VALUE USR-IP-RIP-Policies V2Receive 0x400
-VALUE USR-IP-RIP-Policies Silent 0x80000000
-
-VALUE USR-Callback-Type Normal 1
-VALUE USR-Callback-Type ANI 2
-VALUE USR-Callback-Type Static 3
-VALUE USR-Callback-Type Dynamic 4
-
-VALUE USR-Request-Type Access-Request 1
-VALUE USR-Request-Type Access-Accept 2
-VALUE USR-Request-Type Access-Reject 3
-VALUE USR-Request-Type Accounting-Request 4
-VALUE USR-Request-Type Accounting-Response 5
+VALUE USR-Failure-to-Connect-Reason tooManyUnacked 68
+VALUE USR-Failure-to-Connect-Reason timerExpired 69
+VALUE USR-Failure-to-Connect-Reason t1Glare 70
+VALUE USR-Failure-to-Connect-Reason priDialoutRqTimeout 71
+VALUE USR-Failure-to-Connect-Reason abortAnlgDstOvrIsdn 72
+VALUE USR-Failure-to-Connect-Reason normalUserCallClear 73
+VALUE USR-Failure-to-Connect-Reason normalUnspecified 74
+VALUE USR-Failure-to-Connect-Reason bearerIncompatibility 75
+VALUE USR-Failure-to-Connect-Reason protocolErrorEvent 76
+VALUE USR-Failure-to-Connect-Reason abnormalDisconnect 77
+VALUE USR-Failure-to-Connect-Reason invalidCauseValue 78
+VALUE USR-Failure-to-Connect-Reason resourceUnavailable 79
+VALUE USR-Failure-to-Connect-Reason remoteHungUpDuringTraining 80
+VALUE USR-Failure-to-Connect-Reason trainingTimeout 81
+VALUE USR-Failure-to-Connect-Reason incomingModemNotAvailable 82
+VALUE USR-Failure-to-Connect-Reason incomingInvalidBearerCap 83
+VALUE USR-Failure-to-Connect-Reason incomingInvalidChannelID 84
+VALUE USR-Failure-to-Connect-Reason incomingInvalidProgInd 85
+VALUE USR-Failure-to-Connect-Reason incomingInvalidCallingPty 86
+VALUE USR-Failure-to-Connect-Reason incomingInvalidCalledPty 87
+VALUE USR-Failure-to-Connect-Reason incomingCallBlock 88
+VALUE USR-Failure-to-Connect-Reason incomingLoopStNoRingOff 89
+VALUE USR-Failure-to-Connect-Reason outgoingTelcoDisconnect 90
+VALUE USR-Failure-to-Connect-Reason outgoingEMWinkTimeout 91
+VALUE USR-Failure-to-Connect-Reason outgoingEMWinkTooShort 92
+VALUE USR-Failure-to-Connect-Reason outgoingNoChannelAvail 93
+VALUE USR-Failure-to-Connect-Reason dspReboot 94
+VALUE USR-Failure-to-Connect-Reason noDSPRespToKA 95
+VALUE USR-Failure-to-Connect-Reason noDSPRespToDisc 96
+VALUE USR-Failure-to-Connect-Reason dspTailPtrInvalid 97
+VALUE USR-Failure-to-Connect-Reason dspHeadPtrInvalid 98
+
+VALUE USR-Simplified-MNP-Levels none 1
+VALUE USR-Simplified-MNP-Levels mnpLevel3 2
+VALUE USR-Simplified-MNP-Levels mnpLevel4 3
+VALUE USR-Simplified-MNP-Levels ccittV42 4
+VALUE USR-Simplified-MNP-Levels usRoboticsHST 5
+VALUE USR-Simplified-MNP-Levels synchronousNone 6
+VALUE USR-Simplified-MNP-Levels mnpLevel2 7
+VALUE USR-Simplified-MNP-Levels mnp10 8
+VALUE USR-Simplified-MNP-Levels v42Etc 9
+VALUE USR-Simplified-MNP-Levels mnp10Etc 10
+VALUE USR-Simplified-MNP-Levels lapmEtc 11
+VALUE USR-Simplified-MNP-Levels v42Etc2 12
+VALUE USR-Simplified-MNP-Levels v42SRej 13
+VALUE USR-Simplified-MNP-Levels piafs 14
+
+VALUE USR-Simplified-V42bis-Usage none 1
+VALUE USR-Simplified-V42bis-Usage ccittV42bis 2
+VALUE USR-Simplified-V42bis-Usage mnpLevel5 3
+
+VALUE USR-Equalization-Type Long 1
+VALUE USR-Equalization-Type Short 2
+
+VALUE USR-Fallback-Enabled Disabled 1
+VALUE USR-Fallback-Enabled Enabled 2
+
+VALUE USR-Back-Channel-Data-Rate 450BPS 1
+VALUE USR-Back-Channel-Data-Rate 300BPS 2
+VALUE USR-Back-Channel-Data-Rate None 3
+
+VALUE USR-Device-Connected-To None 1
+VALUE USR-Device-Connected-To isdnGateway 2
+VALUE USR-Device-Connected-To quadModem 3
+
+VALUE USR-Call-Event-Code notSupported 1
+VALUE USR-Call-Event-Code setup 2
+VALUE USR-Call-Event-Code usrSetup 3
+VALUE USR-Call-Event-Code telcoDisconnect 4
+VALUE USR-Call-Event-Code usrDisconnect 5
+VALUE USR-Call-Event-Code noFreeModem 6
+VALUE USR-Call-Event-Code modemsNotAllowed 7
+VALUE USR-Call-Event-Code modemsRejectCall 8
+VALUE USR-Call-Event-Code modemSetupTimeout 9
+VALUE USR-Call-Event-Code noFreeIGW 10
+VALUE USR-Call-Event-Code igwRejectCall 11
+VALUE USR-Call-Event-Code igwSetupTimeout 12
+VALUE USR-Call-Event-Code noFreeTdmts 13
+VALUE USR-Call-Event-Code bcReject 14
+VALUE USR-Call-Event-Code ieReject 15
+VALUE USR-Call-Event-Code chidReject 16
+VALUE USR-Call-Event-Code progReject 17
+VALUE USR-Call-Event-Code callingPartyReject 18
+VALUE USR-Call-Event-Code calledPartyReject 19
+VALUE USR-Call-Event-Code blocked 20
+VALUE USR-Call-Event-Code analogBlocked 21
+VALUE USR-Call-Event-Code digitalBlocked 22
+VALUE USR-Call-Event-Code outOfService 23
+VALUE USR-Call-Event-Code busy 24
+VALUE USR-Call-Event-Code congestion 25
+VALUE USR-Call-Event-Code protocolError 26
+VALUE USR-Call-Event-Code noFreeBchannel 27
+VALUE USR-Call-Event-Code inOutCallCollision 28
+VALUE USR-Call-Event-Code inCallArrival 29
+VALUE USR-Call-Event-Code outCallArrival 30
+VALUE USR-Call-Event-Code inCallConnect 31
+VALUE USR-Call-Event-Code outCallConnect 32
+
+VALUE USR-HARC-Disconnect-Code No-Error 0
+VALUE USR-HARC-Disconnect-Code No-Carrier 1
+VALUE USR-HARC-Disconnect-Code No-DSR 2
+VALUE USR-HARC-Disconnect-Code Timeout 3
+VALUE USR-HARC-Disconnect-Code Reset 4
+VALUE USR-HARC-Disconnect-Code Call-Drop-Req 5
+VALUE USR-HARC-Disconnect-Code Idle-Timeout 6
+VALUE USR-HARC-Disconnect-Code Session-Timeout 7
+VALUE USR-HARC-Disconnect-Code User-Req-Drop 8
+VALUE USR-HARC-Disconnect-Code Host-Req-Drop 9
+VALUE USR-HARC-Disconnect-Code Service-Interruption 10
+VALUE USR-HARC-Disconnect-Code Service-Unavailable 11
+VALUE USR-HARC-Disconnect-Code User-Input-Error 12
+VALUE USR-HARC-Disconnect-Code NAS-Drop-For-Callback 13
+VALUE USR-HARC-Disconnect-Code NAS-Drop-Misc-Non-Error 14
+VALUE USR-HARC-Disconnect-Code NAS-Internal-Error 15
+VALUE USR-HARC-Disconnect-Code Line-Busy 16
+VALUE USR-HARC-Disconnect-Code Tunnel-Term-Unreach 19
+VALUE USR-HARC-Disconnect-Code Tunnel-Refused 20
+VALUE USR-HARC-Disconnect-Code Tunnel-Auth-Failed 21
+VALUE USR-HARC-Disconnect-Code Tunnel-Session-Timeout 22
+VALUE USR-HARC-Disconnect-Code Tunnel-Timeout 23
+VALUE USR-HARC-Disconnect-Code Radius-Res-Reclaim 25
+VALUE USR-HARC-Disconnect-Code DNIS-Auth-Failed 26
+VALUE USR-HARC-Disconnect-Code PAP-Auth-Failure 27
+VALUE USR-HARC-Disconnect-Code CHAP-Auth-Failure 28
+VALUE USR-HARC-Disconnect-Code PPP-LCP-Failed 29
+VALUE USR-HARC-Disconnect-Code PPP-NCP-Failed 30
+VALUE USR-HARC-Disconnect-Code Radius-Timeout 31
+
+VALUE USR-CCP-Algorithm NONE 1
+VALUE USR-CCP-Algorithm Stac 2
+VALUE USR-CCP-Algorithm MS 3
+VALUE USR-CCP-Algorithm Any 4
+
+VALUE USR-Tunnel-Security None 0
+VALUE USR-Tunnel-Security Control-Only 1
+VALUE USR-Tunnel-Security Data-Only 2
+VALUE USR-Tunnel-Security Both-Data-and-Control 3
+
+VALUE USR-RMMIE-Status notEnabledInLocalModem 1
+VALUE USR-RMMIE-Status notDetectedInRemoteModem 2
+VALUE USR-RMMIE-Status ok 3
+
+VALUE USR-RMMIE-x2-Status notOperational 1
+VALUE USR-RMMIE-x2-Status operational 2
+VALUE USR-RMMIE-x2-Status x2Disabled 3
+VALUE USR-RMMIE-x2-Status v8Disabled 4
+VALUE USR-RMMIE-x2-Status remote3200Disabled 5
+VALUE USR-RMMIE-x2-Status invalidSpeedSetting 6
+VALUE USR-RMMIE-x2-Status v8NotDetected 7
+VALUE USR-RMMIE-x2-Status x2NotDetected 8
+VALUE USR-RMMIE-x2-Status incompatibleVersion 9
+VALUE USR-RMMIE-x2-Status incompatibleModes 10
+VALUE USR-RMMIE-x2-Status local3200Disabled 11
+VALUE USR-RMMIE-x2-Status excessHighFrequencyAtten 12
+VALUE USR-RMMIE-x2-Status connectNotSupport3200 13
+VALUE USR-RMMIE-x2-Status retrainBeforeConnection 14
+
+VALUE USR-RMMIE-Planned-Disconnect none 1
+VALUE USR-RMMIE-Planned-Disconnect dteNotReady 2
+VALUE USR-RMMIE-Planned-Disconnect dteInterfaceError 3
+VALUE USR-RMMIE-Planned-Disconnect dteRequest 4
+VALUE USR-RMMIE-Planned-Disconnect escapeToOnlineCommandMode 5
+VALUE USR-RMMIE-Planned-Disconnect athCommand 6
+VALUE USR-RMMIE-Planned-Disconnect inactivityTimeout 7
+VALUE USR-RMMIE-Planned-Disconnect arqProtocolError 8
+VALUE USR-RMMIE-Planned-Disconnect arqProtocolRetransmitLim 9
+VALUE USR-RMMIE-Planned-Disconnect invalidComprDataCodeword 10
+VALUE USR-RMMIE-Planned-Disconnect invalidComprDataStringLen 11
+VALUE USR-RMMIE-Planned-Disconnect invalidComprDataCommand 12
+
+VALUE USR-RMMIE-Last-Update-Event none 1
+VALUE USR-RMMIE-Last-Update-Event initialConnection 2
+VALUE USR-RMMIE-Last-Update-Event retrain 3
+VALUE USR-RMMIE-Last-Update-Event speedShift 4
+VALUE USR-RMMIE-Last-Update-Event plannedDisconnect 5
+
+VALUE USR-Request-Type Access-Request 1
+VALUE USR-Request-Type Access-Accept 2
+VALUE USR-Request-Type Access-Reject 3
+VALUE USR-Request-Type Accounting-Request 4
+VALUE USR-Request-Type Accounting-Response 5
# The next three non standard packet types are used by
# US Robotics Security/Accounting Server
-VALUE USR-Request-Type Access-Password-Change 7
-VALUE USR-Request-Type Access-Password-Ack 8
-VALUE USR-Request-Type Access-Password-Reject 9
-VALUE USR-Request-Type Access-Challenge 11
-VALUE USR-Request-Type Status-Server 12
-VALUE USR-Request-Type Status-Client 13
+VALUE USR-Request-Type Access-Password-Change 7
+VALUE USR-Request-Type Access-Password-Ack 8
+VALUE USR-Request-Type Access-Password-Reject 9
+VALUE USR-Request-Type Access-Challenge 11
+VALUE USR-Request-Type Status-Server 12
+VALUE USR-Request-Type Status-Client 13
# Non standard packet types used by NetServer to implement
# resource management and NAS reboot conditions
-VALUE USR-Request-Type Resource-Free-Request 21
-VALUE USR-Request-Type Resource-Free-Response 22
-VALUE USR-Request-Type Resource-Query-Request 23
-VALUE USR-Request-Type Resource-Query-Response 24
-VALUE USR-Request-Type Disconnect-User 25
-VALUE USR-Request-Type NAS-Reboot-Request 26
-VALUE USR-Request-Type NAS-Reboot-Response 27
+VALUE USR-Request-Type Resource-Free-Request 21
+VALUE USR-Request-Type Resource-Free-Response 22
+VALUE USR-Request-Type Resource-Query-Request 23
+VALUE USR-Request-Type Resource-Query-Response 24
+VALUE USR-Request-Type Disconnect-User 25
+VALUE USR-Request-Type NAS-Reboot-Request 26
+VALUE USR-Request-Type NAS-Reboot-Response 27
# This value is used for Tacacs Plus translation
-VALUE USR-Request-Type Tacacs-Message 253
-VALUE USR-Request-Type Reserved 255
-
-VALUE USR-NAS-Type 3Com-NMC 0
-VALUE USR-NAS-Type 3Com-NETServer 1
-VALUE USR-NAS-Type 3Com-HiPerArc 2
+VALUE USR-Request-Type Tacacs-Message 253
+VALUE USR-Request-Type Reserved 255
+
+VALUE USR-Speed-Of-Connection Auto 0
+VALUE USR-Speed-Of-Connection 56 1
+VALUE USR-Speed-Of-Connection 64 2
+VALUE USR-Speed-Of-Connection Voice 3
+
+VALUE USR-Expansion-Algorithm Constant 1
+VALUE USR-Expansion-Algorithm Linear 2
+
+VALUE USR-Compression-Algorithm None 0
+VALUE USR-Compression-Algorithm Stac 1
+VALUE USR-Compression-Algorithm Ascend 2
+VALUE USR-Compression-Algorithm Microsoft 3
+VALUE USR-Compression-Algorithm Auto 4
+
+VALUE USR-Compression-Reset-Mode Auto 0
+VALUE USR-Compression-Reset-Mode Reset-Every-Packet 1
+VALUE USR-Compression-Reset-Mode Reset-On-Error 2
+
+VALUE USR-Filter-Zones enabled 1
+VALUE USR-Filter-Zones disabled 2
+
+VALUE USR-Bridging enabled 1
+VALUE USR-Bridging disabled 2
+
+VALUE USR-Appletalk enabled 1
+VALUE USR-Appletalk disabled 2
+
+VALUE USR-Spoofing enabled 1
+VALUE USR-Spoofing disabled 2
+
+VALUE USR-Routing-Protocol Rip1 1
+VALUE USR-Routing-Protocol Rip2 2
+
+VALUE USR-IPX-Routing none 0
+VALUE USR-IPX-Routing send 1
+VALUE USR-IPX-Routing listen 2
+VALUE USR-IPX-Routing respond 3
+VALUE USR-IPX-Routing all 4
+
+VALUE USR-IPX-WAN enabled 1
+VALUE USR-IPX-WAN disabled 2
+
+VALUE USR-IP-Default-Route-Option enabled 1
+VALUE USR-IP-Default-Route-Option disabled 2
+
+VALUE USR-IP-RIP-Policies SendDefault 0x0
+VALUE USR-IP-RIP-Policies SendRoutes 0x2
+VALUE USR-IP-RIP-Policies SendSubnets 0x4
+VALUE USR-IP-RIP-Policies AcceptDefault 0x8
+VALUE USR-IP-RIP-Policies SplitHorizon 0x10
+VALUE USR-IP-RIP-Policies PoisonReserve 0x20
+VALUE USR-IP-RIP-Policies FlashUpdate 0x40
+VALUE USR-IP-RIP-Policies SimpleAuth 0x80
+VALUE USR-IP-RIP-Policies V1Send 0x100
+VALUE USR-IP-RIP-Policies V1Receive 0x200
+VALUE USR-IP-RIP-Policies V2Receive 0x400
+VALUE USR-IP-RIP-Policies Silent 0x80000000
+
+VALUE USR-Callback-Type Normal 1
+VALUE USR-Callback-Type ANI 2
+VALUE USR-Callback-Type Static 3
+VALUE USR-Callback-Type Dynamic 4
+
+VALUE USR-Agent FA 1
+VALUE USR-Agent HA 2
+
+VALUE USR-NAS-Type 3Com-NMC 0
+VALUE USR-NAS-Type 3Com-NETServer 1
+VALUE USR-NAS-Type 3Com-HiPerArc 2
VALUE USR-NAS-Type TACACS+-Server 3
-VALUE USR-NAS-Type 3Com-SA-Server 4
-VALUE USR-NAS-Type Ascend 5
-VALUE USR-NAS-Type Generic-RADIUS 6
-VALUE USR-NAS-Type 3Com-NETBuilder-II 7
-
-VALUE USR-Auth-Mode Auth-3Com 0
-VALUE USR-Auth-Mode Auth-Ace 1
-VALUE USR-Auth-Mode Auth-Safeword 2
-VALUE USR-Auth-Mode Auth-UNIX-PW 3
-VALUE USR-Auth-Mode Auth-Defender 4
-VALUE USR-Auth-Mode Auth-TACACSP 5
-VALUE USR-Auth-Mode Auth-Netware 6
-VALUE USR-Auth-Mode Auth-Skey 7
-VALUE USR-Auth-Mode Auth-EAP-Proxy 8
-VALUE USR-Auth-Mode Auth-UNIX-Crypt 9
+VALUE USR-NAS-Type 3Com-SA-Server 4
+VALUE USR-NAS-Type Ascend 5
+VALUE USR-NAS-Type Generic-RADIUS 6
+VALUE USR-NAS-Type 3Com-NETBuilder-II 7
+
+VALUE USR-Auth-Mode Auth-3Com 0
+VALUE USR-Auth-Mode Auth-Ace 1
+VALUE USR-Auth-Mode Auth-Safeword 2
+VALUE USR-Auth-Mode Auth-UNIX-PW 3
+VALUE USR-Auth-Mode Auth-Defender 4
+VALUE USR-Auth-Mode Auth-TACACSP 5
+VALUE USR-Auth-Mode Auth-Netware 6
+VALUE USR-Auth-Mode Auth-Skey 7
+VALUE USR-Auth-Mode Auth-EAP-Proxy 8
+VALUE USR-Auth-Mode Auth-UNIX-Crypt 9
+
+VALUE CW-Acct-Type COMS-UNKNOWN-ACCT-TYPE 0
+VALUE CW-Acct-Type COMS-PREPAID-ACCT 1
+VALUE CW-Acct-Type COMS-NEW-ACCT 2
+VALUE CW-Acct-Type COMS-SUSPENDED-ACCT 3
+VALUE CW-Acct-Type COMS-ADMINISTRATIVE-ACCT 4
+
+VALUE CW-Source-Identifier COMS-UNKNOWN-SOURCE 0
+VALUE CW-Source-Identifier COMS-INGRESS-OPEN 257
+VALUE CW-Source-Identifier COMS-EGRESS-OPEN 258
+VALUE CW-Source-Identifier COMS-GTKPR-GEN-INGR-OPEN 259
+VALUE CW-Source-Identifier COMS-GTKPR-GEN-EGR-OPEN 260
+VALUE CW-Source-Identifier COMS-INGRESS-CLOSE 513
+VALUE CW-Source-Identifier COMS-EGRESS-CLOSE 514
+VALUE CW-Source-Identifier COMS-GTKPR-GEN-INGR-CLOSE 515
+VALUE CW-Source-Identifier COMS-GTKPR-GEN-EGR-CLOSE 516
+
+VALUE CW-Session-Sequence-End NOT-THE-LAST-CALL 0
+VALUE CW-Session-Sequence-End LAST-CALL 1
+
+VALUE CW-Clg-Party-E164-Type comsUnknown 1
+VALUE CW-Clg-Party-E164-Type comsInternationalNumber 2
+VALUE CW-Clg-Party-E164-Type comsNationalNumber 3
+VALUE CW-Clg-Party-E164-Type comsNetworkSpecificNumber 4
+VALUE CW-Clg-Party-E164-Type comsSubscriberNumber 5
+VALUE CW-Clg-Party-E164-Type comsAbbreviatedNumber 6
+VALUE CW-Clg-Party-E164-Type comsReserved 7
+
+VALUE CW-Clg-Party-Trans-Protocol TCP 1
+VALUE CW-Clg-Party-Trans-Protocol UDP 2
+VALUE CW-Clg-Party-Trans-Protocol SCTP 3
+
+VALUE CW-Cld-Party-E164-Type comsUnknown 1
+VALUE CW-Cld-Party-E164-Type comsInternationalNumber 2
+VALUE CW-Cld-Party-E164-Type comsNationalNumber 3
+VALUE CW-Cld-Party-E164-Type comsNetworkSpecificNumber 4
+VALUE CW-Cld-Party-E164-Type comsSubscriberNumber 5
+VALUE CW-Cld-Party-E164-Type comsAbbreviatedNumber 6
+VALUE CW-Cld-Party-E164-Type comsReserved 7
+
+VALUE CW-Cld-Party-Trans-Protocol TCP 1
+VALUE CW-Cld-Party-Trans-Protocol UDP 2
+VALUE CW-Cld-Party-Trans-Protocol SCTP 3
+
+VALUE CW-Ingr-Gway-E164-Type comsUnknown 1
+VALUE CW-Ingr-Gway-E164-Type comsInternationalNumber 2
+VALUE CW-Ingr-Gway-E164-Type comsNationalNumber 3
+VALUE CW-Ingr-Gway-E164-Type comsNetworkSpecificNumber 4
+VALUE CW-Ingr-Gway-E164-Type comsSubscriberNumber 5
+VALUE CW-Ingr-Gway-E164-Type comsAbbreviatedNumber 6
+VALUE CW-Ingr-Gway-E164-Type comsReserved 7
+
+VALUE CW-Ingr-Gway-Trans-Protocol TCP 1
+VALUE CW-Ingr-Gway-Trans-Protocol UDP 2
+VALUE CW-Ingr-Gway-Trans-Protocol SCTP 3
+
+VALUE CW-Egr-Gway-Trans-Protocol TCP 1
+VALUE CW-Egr-Gway-Trans-Protocol UDP 2
+VALUE CW-Egr-Gway-Trans-Protocol SCTP 3
+
+VALUE CW-Ingr-Gtkpr-Trans-Protocol TCP 1
+VALUE CW-Ingr-Gtkpr-Trans-Protocol UDP 2
+VALUE CW-Ingr-Gtkpr-Trans-Protocol SCTP 3
+
+VALUE CW-Egr-Gtkpr-Trans-Protocol TCP 1
+VALUE CW-Egr-Gtkpr-Trans-Protocol UDP 2
+VALUE CW-Egr-Gtkpr-Trans-Protocol SCTP 3
+
+VALUE CW-Call-Type COMS-UNKNOWN-CALLTYPE 0
+VALUE CW-Call-Type COMS-PHONE-TO-PHONE 1
+VALUE CW-Call-Type COMS-PHONE-TO-PC 2
+VALUE CW-Call-Type COMS-PC-TO-PHONE 3
+VALUE CW-Call-Type COMS-PC-TO-PC 4
+
+VALUE CW-Codec-Type COMS-UNDEFINED-CODEC 0
+VALUE CW-Codec-Type COMS-G723-1 1
+VALUE CW-Codec-Type COMS-G729-A 2
+VALUE CW-Codec-Type COMS-G710-ALaw 3
+VALUE CW-Codec-Type COMS-G711-MuLaw 4
+VALUE CW-Codec-Type COMS-FAX-MODULATION 255
+
+VALUE CW-Call-Termination-Cause CAUSE-UNKNOWN 0
+VALUE CW-Call-Termination-Cause CAUSE-CLD-PARTY-TERMINATE 1
+VALUE CW-Call-Termination-Cause CAUSE-CLG-PARTY-TERMINATE 2
+VALUE CW-Call-Termination-Cause CAUSE-ACCT-BAL-DEPLETED 3
+VALUE CW-Call-Termination-Cause CAUSE-NO-EGR-PORTS-AVAIL 4
+VALUE CW-Call-Termination-Cause CAUSE-H225-UNABLE-TO-CON 5
+VALUE CW-Call-Termination-Cause CAUSE-H245-UNABLE-TO-CON 6
+VALUE CW-Call-Termination-Cause CAUSE-INGR-FACILITY-DISC 7
+VALUE CW-Call-Termination-Cause CAUSE-EGR-FACILITY-DISC 8
+VALUE CW-Call-Termination-Cause CAUSE-DIR-SERVER-DOWN 9
+VALUE CW-Call-Termination-Cause CAUSE-RATING-SERVER-DOWN 10
+VALUE CW-Call-Termination-Cause CAUSE-GATEWAY-SHUTDOWN 11
+VALUE CW-Call-Termination-Cause CAUSE-GTKPR-TERMINATE 12
+VALUE CW-Call-Termination-Cause CAUSE-GTKPR-SHUTDOWN-GTWAY 13
+VALUE CW-Call-Termination-Cause CAUSE-BUSY 14
+VALUE CW-Call-Termination-Cause CAUSE-ABANDON 15
+VALUE CW-Call-Termination-Cause CAUSE-INVALID-LOGIN-LIMIT 16
+VALUE CW-Call-Termination-Cause CAUSE-NOACCTNUMBER-ENTRY 17
+VALUE CW-Call-Termination-Cause CAUSE-SUSPENDED-ACCT-LOGIN 18
+VALUE CW-Call-Termination-Cause CAUSE-AUTHENT-SERVER-DOWN 19
+VALUE CW-Call-Termination-Cause CAUSE-GATEKEEPER-TIMEOUT 20
+VALUE CW-Call-Termination-Cause CAUSE-GATEWAY-NO-RESOURCES 21
+VALUE CW-Call-Termination-Cause CAUSE-ACCT-INUSE 22
+VALUE CW-Call-Termination-Cause CAUSE-DEBIT-ACCT-BAL-ZERO 23
+VALUE CW-Call-Termination-Cause CAUSE-DEBIT-ACCTBAL-INSUFF 24
+VALUE CW-Call-Termination-Cause CAUSE-INVALID-DESTNUMBER-THRESH 25
+VALUE CW-Call-Termination-Cause CAUSE-NO-DESTNUMBER-ENTRY 26
+VALUE CW-Call-Termination-Cause CAUSE-SEQUENCE-DIALING-THRESH 27
+
+VALUE CW-Signaling-Protocol SIG-UNKNOWN 0
+VALUE CW-Signaling-Protocol SIG-SIP 1
+VALUE CW-Signaling-Protocol SIG-H323 2
+
+VALUE CW-Protocol-Transport TCP 1
+VALUE CW-Protocol-Transport UDP 2
+VALUE CW-Protocol-Transport SCTP 3
+
+VALUE CW-Local-Sig-Trans-Protocol TCP 1
+VALUE CW-Local-Sig-Trans-Protocol UDP 2
+VALUE CW-Local-Sig-Trans-Protocol SCTP 3
+
+VALUE CW-Remote-Sig-Trans-Protocol TCP 1
+VALUE CW-Remote-Sig-Trans-Protocol UDP 2
+VALUE CW-Remote-Sig-Trans-Protocol SCTP 3
+
+VALUE CW-Local-MG-RTP-Protocol TCP 1
+VALUE CW-Local-MG-RTP-Protocol UDP 2
+VALUE CW-Local-MG-RTP-Protocol SCTP 3
+
+VALUE CW-Remote-MG-RTP-Protocol TCP 1
+VALUE CW-Remote-MG-RTP-Protocol UDP 2
+VALUE CW-Remote-MG-RTP-Protocol SCTP 3
+
+VALUE CW-Trans-Cld-Party-E164-Type Unknown 1
+VALUE CW-Trans-Cld-Party-E164-Type International-Number 2
+VALUE CW-Trans-Cld-Party-E164-Type National-Number 3
+VALUE CW-Trans-Cld-Party-E164-Type Network-Specific-Number 4
+VALUE CW-Trans-Cld-Party-E164-Type Subscriber-Number 5
+VALUE CW-Trans-Cld-Party-E164-Type Abbreviated-Number 6
+VALUE CW-Trans-Cld-Party-E164-Type Reserved 7
+
END-VENDOR USR
+# -*- text -*-
#
# Valemount Networks Corporation specific radius attributes
# networks@valemount.com
# $Id$
#
-VENDOR ValemountNetworks 16313
+VENDOR ValemountNetworks 16313
BEGIN-VENDOR ValemountNetworks
# Rates to give PPPoE customers, can be used in Authentication replies,
# in bits/s
-ATTRIBUTE VNC-PPPoE-CBQ-RX 1 integer
-ATTRIBUTE VNC-PPPoE-CBQ-TX 2 integer
+ATTRIBUTE VNC-PPPoE-CBQ-RX 1 integer
+ATTRIBUTE VNC-PPPoE-CBQ-TX 2 integer
# Fallback support for each direction. (1 / 0)
-ATTRIBUTE VNC-PPPoE-CBQ-RX-Fallback 3 integer
-ATTRIBUTE VNC-PPPoE-CBQ-TX-Fallback 4 integer
+ATTRIBUTE VNC-PPPoE-CBQ-RX-Fallback 3 integer
+ATTRIBUTE VNC-PPPoE-CBQ-TX-Fallback 4 integer
-ATTRIBUTE VNC-Splash 10 integer
+ATTRIBUTE VNC-Splash 10 integer
-VALUE VNC-Splash Show 1
-VALUE VNC-Splash No-Show 0
+VALUE VNC-Splash Show 1
+VALUE VNC-Splash No-Show 0
END-VENDOR ValemountNetworks
-#\r
-# dictionary.versanet Vendor specfic attributes for versanet\r
-#\r
-#\r
-# VersaNet Communications, Inc.\r
-# Http://www.versa-net.com\r
-#\r
-#\r
-#Versanet add Vendor specific terminal cause in our radius group.\r
-#You can follow this to set it in NAS box.\r
-#\r
-# >> gr radius\r
-# >> sh\r
-# >> set 34 23\r
-# >> co\r
-#\r
-#This will let our unit transfer every detail terminal cause \r
-#information to Redius server's accounting log file and \r
-#save as "Vendor Specific=Terminate Cause". \r
-#\r
-# Version: @(#)dictionary.versanet 1.00 22-Jul-1999 support@versanetcomm.com\r
-#\r
-\r
-VENDOR Versanet 2180\r
-\r
-ATTRIBUTE Versanet-Termination-Cause 1 integer Versanet\r
-\r
-VALUE Versanet-Termination-Cause Normal-Hangup-No-Error-Occurred 0\r
-VALUE Versanet-Termination-Cause Call-Waiting-Caused-Disconnect 3\r
-VALUE Versanet-Termination-Cause Physical-Carrier-Loss 4\r
-VALUE Versanet-Termination-Cause No-err-correction-at-other-end 5\r
-VALUE Versanet-Termination-Cause No-resp-to-feature-negotiation 6\r
-VALUE Versanet-Termination-Cause 1st-modem-async-only-2nd-sync 7\r
-VALUE Versanet-Termination-Cause No-framing-technique-in-common 8\r
-VALUE Versanet-Termination-Cause No-protocol-in-common 9\r
-VALUE Versanet-Termination-Cause Bad-resp-to-feature-negotiation 10\r
-VALUE Versanet-Termination-Cause No-sync-info-from-remote-modem 11\r
-VALUE Versanet-Termination-Cause Normal-Hangup-by-Remote-modem 12\r
-VALUE Versanet-Termination-Cause Retransmission-limit-reached 13\r
-VALUE Versanet-Termination-Cause Protocol-violation-occurred 14\r
-VALUE Versanet-Termination-Cause Lost-DTR 15\r
-VALUE Versanet-Termination-Cause Received-GSTN-cleardown 16\r
-VALUE Versanet-Termination-Cause Inactivity-timeout 17\r
-VALUE Versanet-Termination-Cause Speed-not-supported 18\r
-VALUE Versanet-Termination-Cause Long-space-disconnect 19\r
-VALUE Versanet-Termination-Cause Key-abort-disconnect 20\r
-VALUE Versanet-Termination-Cause Clears-previous-disc-reason 21\r
-VALUE Versanet-Termination-Cause No-connection-established 22\r
-VALUE Versanet-Termination-Cause Disconnect-after-three-retrains 23\r
-\r
+# -*- text -*-
+#
+# dictionary.versanet Vendor specfic attributes for versanet
+#
+#
+# VersaNet Communications, Inc.
+# Http://www.versa-net.com
+#
+#
+#Versanet add Vendor specific terminal cause in our radius group.
+#You can follow this to set it in NAS box.
+#
+# >> gr radius
+# >> sh
+# >> set 34 23
+# >> co
+#
+#This will let our unit transfer every detail terminal cause
+#information to Redius server's accounting log file and
+#save as "Vendor Specific=Terminate Cause".
+#
+# Version: @(#)dictionary.versanet 1.00 22-Jul-1999 support@versanetcomm.com
+#
+
+VENDOR Versanet 2180
+
+BEGIN-VENDOR Versanet
+
+ATTRIBUTE Versanet-Termination-Cause 1 integer
+
+VALUE Versanet-Termination-Cause Normal-Hangup-No-Error-Occurred 0
+VALUE Versanet-Termination-Cause Call-Waiting-Caused-Disconnect 3
+VALUE Versanet-Termination-Cause Physical-Carrier-Loss 4
+VALUE Versanet-Termination-Cause No-err-correction-at-other-end 5
+VALUE Versanet-Termination-Cause No-resp-to-feature-negotiation 6
+VALUE Versanet-Termination-Cause 1st-modem-async-only-2nd-sync 7
+VALUE Versanet-Termination-Cause No-framing-technique-in-common 8
+VALUE Versanet-Termination-Cause No-protocol-in-common 9
+VALUE Versanet-Termination-Cause Bad-resp-to-feature-negotiation 10
+VALUE Versanet-Termination-Cause No-sync-info-from-remote-modem 11
+VALUE Versanet-Termination-Cause Normal-Hangup-by-Remote-modem 12
+VALUE Versanet-Termination-Cause Retransmission-limit-reached 13
+VALUE Versanet-Termination-Cause Protocol-violation-occurred 14
+VALUE Versanet-Termination-Cause Lost-DTR 15
+VALUE Versanet-Termination-Cause Received-GSTN-cleardown 16
+VALUE Versanet-Termination-Cause Inactivity-timeout 17
+VALUE Versanet-Termination-Cause Speed-not-supported 18
+VALUE Versanet-Termination-Cause Long-space-disconnect 19
+VALUE Versanet-Termination-Cause Key-abort-disconnect 20
+VALUE Versanet-Termination-Cause Clears-previous-disc-reason 21
+VALUE Versanet-Termination-Cause No-connection-established 22
+VALUE Versanet-Termination-Cause Disconnect-after-three-retrains 23
+
+END-VENDOR Versanet
--- /dev/null
+# -*- text -*-
+#
+# http://www.waverider.com/
+# $Id$
+#
+
+VENDOR Waverider 2979
+
+BEGIN-VENDOR Waverider
+ATTRIBUTE Waverider-Grade-Of-Service 1 integer
+ATTRIBUTE Waverider-Priority-Enabled 2 integer
+ATTRIBUTE Waverider-Current-Password 5 string
+ATTRIBUTE Waverider-New-Password 6 string
+ATTRIBUTE Waverider-Radio-Frequency 7 integer
+ATTRIBUTE WaveRider-SNMP-Read-Community 8 string
+ATTRIBUTE WaveRider-SNMP-Write-Community 9 string
+ATTRIBUTE WaveRider-SNMP-Trap-Community 10 string
+ATTRIBUTE WaveRider-SNMP-Contact 11 string
+ATTRIBUTE WaveRider-SNMP-Location 12 string
+ATTRIBUTE WaveRider-SNMP-Name 13 string
+ATTRIBUTE WaveRider-Max-Customers 14 integer
+ATTRIBUTE WaveRider-Rf-Power 15 integer
+
+VALUE Waverider-Grade-Of-Service be 1
+VALUE Waverider-Grade-Of-Service bronze 2
+VALUE Waverider-Grade-Of-Service silver 3
+VALUE Waverider-Grade-Of-Service gold 4
+
+VALUE WaveRider-Priority-Enabled disabled 0
+VALUE WaveRider-Priority-Enabled enabled 1
+
+VALUE WaveRider-Radio-Frequency auto 1
+VALUE WaveRider-Radio-Frequency nomadic 2
+VALUE WaveRider-Radio-Frequency f_9050 3
+VALUE WaveRider-Radio-Frequency f_9116 4
+VALUE WaveRider-Radio-Frequency f_9184 5
+VALUE WaveRider-Radio-Frequency f_9250 6
+VALUE WaveRider-Radio-Frequency f_9084 7
+VALUE WaveRider-Radio-Frequency f_9150 8
+VALUE WaveRider-Radio-Frequency f_9216 9
+
+VALUE WaveRider-Rf-Power p_15 1
+VALUE WaveRider-Rf-Power p_16 2
+VALUE WaveRider-Rf-Power p_17 3
+VALUE WaveRider-Rf-Power p_18 4
+VALUE WaveRider-Rf-Power p_19 5
+VALUE WaveRider-Rf-Power p_20 6
+VALUE WaveRider-Rf-Power p_21 7
+VALUE WaveRider-Rf-Power p_22 8
+VALUE WaveRider-Rf-Power p_23 9
+VALUE WaveRider-Rf-Power p_24 10
+VALUE WaveRider-Rf-Power p_25 11
+VALUE WaveRider-Rf-Power p_26 12
+
+END-VENDOR Waverider
+# -*- text -*-
#
# dictionary.wispr
#
#
# http://www.weca.net/OpenSection/downloads/WISPr_V1.0.pdf
-VENDOR WISPr 14122
+VENDOR WISPr 14122
#
# Standard attribute
#
-ATTRIBUTE WISPr-Location-ID 1 string WISPr
-ATTRIBUTE WISPr-Location-Name 2 string WISPr
-ATTRIBUTE WISPr-Logoff-URL 3 string WISPr
-ATTRIBUTE WISPr-Redirection-URL 4 string WISPr
-ATTRIBUTE WISPr-Bandwidth-Min-Up 5 integer WISPr
-ATTRIBUTE WISPr-Bandwidth-Min-Down 6 integer WISPr
-ATTRIBUTE WISPr-Bandwidth-Max-Up 7 integer WISPr
-ATTRIBUTE WISPr-Bandwidth-Max-Down 8 integer WISPr
-ATTRIBUTE WISPr-Session-Terminate-Time 9 string WISPr
-ATTRIBUTE WISPr-Session-Terminate-End-Of-Day 10 string WISPr
-ATTRIBUTE WISPr-Billing-Class-Of-Service 11 string WISPr
+BEGIN-VENDOR WISPr
+
+ATTRIBUTE WISPr-Location-ID 1 string
+ATTRIBUTE WISPr-Location-Name 2 string
+ATTRIBUTE WISPr-Logoff-URL 3 string
+ATTRIBUTE WISPr-Redirection-URL 4 string
+ATTRIBUTE WISPr-Bandwidth-Min-Up 5 integer
+ATTRIBUTE WISPr-Bandwidth-Min-Down 6 integer
+ATTRIBUTE WISPr-Bandwidth-Max-Up 7 integer
+ATTRIBUTE WISPr-Bandwidth-Max-Down 8 integer
+ATTRIBUTE WISPr-Session-Terminate-Time 9 string
+ATTRIBUTE WISPr-Session-Terminate-End-Of-Day 10 string
+ATTRIBUTE WISPr-Billing-Class-Of-Service 11 string
+
+END-VENDOR WISPr
+# -*- text -*-
##############################################################################
#
# XEDIA, AP series routers
# $Id$
#
#############################################################################
-VENDOR Xedia 838
+VENDOR Xedia 838
-ATTRIBUTE Xedia-DNS-Server 1 ipaddr Xedia
-ATTRIBUTE Xedia-NetBios-Server 2 ipaddr Xedia
-ATTRIBUTE Xedia-Address-Pool 3 string Xedia
-ATTRIBUTE Xedia-PPP-Echo-Interval 4 integer Xedia
-ATTRIBUTE Xedia-SSH-Privileges 5 integer Xedia
-ATTRIBUTE Xedia-Client-Access-Network 6 string Xedia
+BEGIN-Vendor Xedia
+
+ATTRIBUTE Xedia-DNS-Server 1 ipaddr
+ATTRIBUTE Xedia-NetBios-Server 2 ipaddr
+ATTRIBUTE Xedia-Address-Pool 3 string
+ATTRIBUTE Xedia-PPP-Echo-Interval 4 integer
+ATTRIBUTE Xedia-SSH-Privileges 5 integer
+ATTRIBUTE Xedia-Client-Access-Network 6 string
+ATTRIBUTE Xedia-Client-Firewall-Setting 7 integer
+ATTRIBUTE Xedia-Save-Password 8 integer
+
+END-VENDOR Xedia
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Xylan dictionary
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Xylan 800
+
+BEGIN-VENDOR Xylan
+
+ATTRIBUTE Xylan-Auth-Group 1 integer
+ATTRIBUTE Xylan-Slot-Port 2 string
+ATTRIBUTE Xylan-Time-of-Day 3 string
+ATTRIBUTE Xylan-Client-IP-Addr 4 ipaddr
+ATTRIBUTE Xylan-Group-Desc 5 string
+ATTRIBUTE Xylan-Port-Desc 6 string
+ATTRIBUTE Xylan-Profil-Numb 7 integer
+ATTRIBUTE Xylan-Auth-Group-Protocol 8 string
+ATTRIBUTE Xylan-Asa-Access 9 string
+ATTRIBUTE Xylan-Access-Priv 16 integer
+ATTRIBUTE Xylan-Acce-Priv-R1 33 octets
+ATTRIBUTE Xylan-Acce-Priv-R2 34 octets
+ATTRIBUTE Xylan-Acce-Priv-W1 35 octets
+ATTRIBUTE Xylan-Acce-Priv-W2 36 octets
+ATTRIBUTE Xylan-Acce-Priv-G1 37 octets
+ATTRIBUTE Xylan-Acce-Priv-G2 38 octets
+ATTRIBUTE Xylan-Acce-Priv-F-R1 39 octets
+ATTRIBUTE Xylan-Acce-Priv-F-R2 40 octets
+ATTRIBUTE Xylan-Acce-Priv-F-W1 41 octets
+ATTRIBUTE Xylan-Acce-Priv-F-W2 42 octets
+
+VALUE Xylan-Access-Priv Xylan-Read-Priv 1
+VALUE Xylan-Access-Priv Xylan-Write-Priv 2
+VALUE Xylan-Access-Priv Xylan-Admin-Priv 3
+
+END-VENDOR Xylan
--- /dev/null
+# -*- text -*-
+##############################################################################
+#
+# Zyxel attributes, of course in the RFC space...
+#
+# This dictionary is NOT included by default, because it conflicts
+# with other dictionaries!
+#
+# http://www.zyxel.com/support/supportnote/p200/ap_note/isdn/radius.htm
+#
+# $Id$
+#
+##############################################################################
+
+VENDOR Zyxel
+
+ATTRIBUTE Zyxel-Callback-Option 192 integer
+ATTRIBUTE Zyxel-Callback-Phone-Source 193 integer
+
+VALUE Zyxel-Callback-Phone-Source Preconfigured 0
+VALUE Zyxel-Callback-Phone-Source User 1
+
+VALUE Zyxel-Callback-Option None 0
+VALUE Zyxel-Callback-Option Optional 1
+VALUE Zyxel-Callback-Option Mandatory 2
--- /dev/null
+#!/usr/bin/env perl
+#
+# Format the dictionaries according to a standard scheme.
+#
+# Usage: cat dictionary | ./format.pl > new
+#
+# We don't over-write the dictionaries in place, so that the process
+# can be double-checked by hand.
+#
+# This is a bit of a hack.
+#
+# FIXME: get lengths from variables, rather than hard-coding.
+#
+# $Id$
+#
+
+$begin_vendor = 0;
+$blank = 0;
+
+while (<>) {
+ #
+ # Clear out trailing whitespace
+ #
+ s/[ \t]+$//;
+
+ #
+ # And CR's
+ #
+ s/\r//g;
+
+ #
+ # Suppress multiple blank lines
+ #
+ if (/^\s+$/) {
+ next if ($blank == 1);
+ $blank = 1;
+ print "\n";
+ next;
+ }
+ $blank = 0;
+
+ #
+ # Remember the vendor
+ #
+ if (/^VENDOR\s+([\w-]+)\s+(\w+)(.*)/) {
+ $name=$1;
+ $len = length $name;
+ if ($len < 32) {
+ $lenx = 32 - $len;
+ $lenx += 7; # round up
+ $lenx /= 8;
+ $lenx = int $lenx;
+ $tabs = "\t" x $lenx;
+ } else {
+ $tabs = " ";
+ }
+ print "VENDOR\t\t$name$tabs$2$3\n";
+ $vendor = $name;
+ next;
+ }
+
+ #
+ # Remember if we did begin-vendor.
+ #
+ if (/^BEGIN-VENDOR\s+([\w-]+)/) {
+ $begin_vendor = 1;
+ print "BEGIN-VENDOR\t$vendor\n";
+ next;
+ }
+
+ #
+ # Get attribute.
+ #
+ if (/^ATTRIBUTE\s+([\w-]+)\s+(\w+)\s+(\w+)(.*)/) {
+ $name=$1;
+ $len = length $name;
+ if ($len < 40) {
+ $lenx = 40 - $len;
+ $lenx += 7; # round up
+ $lenx /= 8;
+ $lenx = int $lenx;
+ $tabs = "\t" x $lenx;
+ if ($tabs eq "") {
+ $tabs = " ";
+ }
+ } else {
+ $tabs = " ";
+ }
+
+ $value = $2;
+ $type = $3;
+ $stuff = $4;
+
+ #
+ # See if it's old format, with the vendor at the end of
+ # the line. If so, make it the new format.
+ #
+ if ($stuff =~ /$vendor/) {
+ if ($begin_vendor == 0) {
+ print "BEGIN-VENDOR\t$vendor\n\n";
+ $begin_vendor = 1;
+ }
+ $stuff =~ s/$vendor//;
+ $stuff =~ s/\s+$//;
+ }
+
+ print "ATTRIBUTE\t$name$tabs$value\t$type$stuff\n";
+ next;
+ }
+
+ #
+ # Values.
+ #
+ if (/^VALUE\s+([\w-]+)\s+([\w-\/,.]+)\s+(\w+)(.*)/) {
+ $attr=$1;
+ $len = length $attr;
+ if ($len < 32) {
+ $lenx = 32 - $len;
+ $lenx += 7; # round up
+ $lenx /= 8;
+ $lenx = int $lenx;
+ $tabsa = "\t" x $lenx;
+ if ($tabsa eq "") {
+ $tabsa = " ";
+ $len += 1;
+ } else {
+ $len -= $len % 8;
+ $len += 8 * length $tabsa;
+ }
+ } else {
+ $tabsa = " ";
+ $len += 1;
+ }
+
+ #
+ # For the code below, we assume that the attribute lengths
+ #
+ if ($len < 32) {
+ $lena = 0;
+ } else {
+ $lena = $len - 32;
+ }
+
+ $name = $2;
+ $len = length $name;
+ if ($len < 24) {
+ $lenx = 24 - $lena - $len;
+ $lenx += 7; # round up
+ $lenx /= 8;
+ $lenx = int $lenx;
+ $tabsn = "\t" x $lenx;
+ if ($tabsn eq "") {
+ $tabsn = " ";
+ }
+ } else {
+ $tabsn = " ";
+ }
+
+ print "VALUE\t$attr$tabsa$name$tabsn$3$4\n";
+ next;
+ }
+
+ #
+ # Remember if we did this.
+ #
+ if (/^END-VENDOR/) {
+ $begin_vendor = 0;
+ }
+
+ #
+ # Everything else gets dumped out as-is.
+ #
+ print;
+}
+
+#
+# If we changed the format, print the end vendor, too.
+#
+if ($begin_vendor) {
+ print "\nEND-VENDOR\t$vendor\n";
+}
#ifdef _LIBRADIUS
# define AUTH_HDR_LEN 20
# define VENDORPEC_USR 429
+#define VENDORPEC_LUCENT 4846
+#define VENDORPEC_STARENT 8164
# define VENDOR(x) ((x >> 16) & 0xffff)
# define DEBUG if (librad_debug) printf
# define debug_pair(vp) do { if (librad_debug) { \
} DICT_ATTR;
typedef struct dict_value {
- char name[40];
int attr;
int value;
+ char name[1];
} DICT_VALUE;
typedef struct dict_vendor {
- char name[40];
int vendorpec;
- struct dict_vendor *next;
+ int type; /* length of type data */
+ int length; /* length of length data */
+ char name[1];
} DICT_VENDOR;
typedef struct value_pair {
*/
int dict_addvendor(const char *name, int value);
int dict_addattr(const char *name, int vendor, int type, int value, ATTR_FLAGS flags);
-int dict_addvalue(const char *namestr, char *attrstr, int value);
+int dict_addvalue(const char *namestr, const char *attrstr, int value);
int dict_init(const char *dir, const char *fn);
DICT_ATTR *dict_attrbyvalue(int attr);
DICT_ATTR *dict_attrbyname(const char *attr);
int rad_tunnel_pwencode(char *encpw, int *len, const char *secret, const char *vector);
int rad_tunnel_pwdecode(uint8_t *encpw, int *len, const char *secret, const char *vector);
int rad_chap_encode(RADIUS_PACKET *packet, char *output, int id, VALUE_PAIR *password);
+int rad_vp2attr(const RADIUS_PACKET *packet,
+ const RADIUS_PACKET *original, const char *secret,
+ const VALUE_PAIR *vp, uint8_t *ptr);
+int rad_encode(RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret);
+int rad_sign(RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret);
/* valuepair.c */
VALUE_PAIR *paircreate(int attr, int type);
uint32_t ip_addr(const char *);
char *ifid_ntoa(char *buffer, size_t size, uint8_t *ifid);
uint8_t *ifid_aton(const char *ifid_str, uint8_t *ifid);
-char *ipv6_ntoa(char *buffer, size_t size, void *ip6addr);
+const char *ipv6_ntoa(char *buffer, size_t size, void *ip6addr);
int ipv6_addr(const char *ip6_str, void *ip6addr);
char *strNcpy(char *dest, const char *src, int n);
void rad_lowercase(char *str);
void print_abinary(VALUE_PAIR *vp, u_char *buffer, int len);
#endif /*ASCEND_BINARY*/
-#ifdef HAVE_LOCAL_SNPRINTF
+/* snprintf.c */
+#ifndef HAVE_VSNPRINTF
#include <stdarg.h>
-int snprintf(char *str, size_t count, const char *fmt, ...);
int vsnprintf(char *str, size_t count, const char *fmt, va_list arg);
#endif
+#ifndef HAVE_SNPRINTF
+int snprintf(char *str, size_t count, const char *fmt, ...);
+#endif
/* random numbers in isaac.c */
/* context of random number generator */
void lrad_isaac(lrad_randctx *ctx);
void lrad_randinit(lrad_randctx *ctx, int flag);
uint32_t lrad_rand(void); /* like rand(), but better. */
+void lrad_rand_seed(const void *, size_t ); /* seed the random pool */
/* crypt wrapper from crypt.c */
int lrad_crypt_check(const char *key, const char *salt);
typedef enum { PreOrder, InOrder, PostOrder } RBTREE_ORDER;
int rbtree_walk(rbtree_t *tree, int (*callback)(void *), RBTREE_ORDER order);
+/*
+ * Fast hash, which isn't too bad. Don't use for cryptography,
+ * just for hashing internal data.
+ */
+uint32_t lrad_hash(const void *, size_t);
+uint32_t lrad_hash_update(const void *data, size_t size, uint32_t hash);
+
+/*
+ * If you need fewer than 32-bits of hash, use this macro to get
+ * the number of bits in the hash you need. The upper bits of the
+ * hash will be set to zero.
+ */
+uint32_t lrad_hash_fold(uint32_t hash, int bits);
+
+typedef struct lrad_hash_table_t lrad_hash_table_t;
+
+lrad_hash_table_t *lrad_hash_table_create(int size, void (*freeNode)(void *),
+ int replace_flag);
+void lrad_hash_table_free(lrad_hash_table_t *ht);
+int lrad_hash_table_insert(lrad_hash_table_t *ht, uint32_t key,
+ void *data);
+int lrad_hash_table_delete(lrad_hash_table_t *ht, uint32_t key);
+void *lrad_hash_table_finddata(lrad_hash_table_t *ht, uint32_t key);
+int lrad_hash_table_num_elements(lrad_hash_table_t *ht);
+int lrad_hash_table_walk(lrad_hash_table_t *ht,
+ int (*callback)(void * /* ctx */,
+ void * /* data */),
+ void *context);
+int lrad_hash_table_set_data_size(lrad_hash_table_t *ht,
+ size_t data_size);
#endif /*LIBRADIUS_H*/
SRCS = dict.c print.c radius.c valuepair.c token.c misc.c \
log.c filters.c missing.c md4.c md5.c sha1.c \
hmac.c hmacsha1.c snprintf.c isaac.c crypt.c \
- udpfromto.c rbtree.c
+ udpfromto.c rbtree.c hash.c
INCLUDES = ../include/radius.h ../include/libradius.h \
../include/missing.h ../include/autoconf.h
#include <malloc.h>
#endif
-#include "libradius.h"
+#ifdef HAVE_SYS_STAT_H
+#include <sys/stat.h>
+#endif
+
+#include <unistd.h>
+
#include "missing.h"
+#include "libradius.h"
+
+#define DICT_VALUE_MAX_NAME_LEN (128)
+#define DICT_VENDOR_MAX_NAME_LEN (128)
+
+static lrad_hash_table_t *vendors_byname = NULL;
+static lrad_hash_table_t *vendors_byvalue = NULL;
+
+static lrad_hash_table_t *attributes_byname = NULL;
+static lrad_hash_table_t *attributes_byvalue = NULL;
+
+static lrad_hash_table_t *values_byvalue = NULL;
+static lrad_hash_table_t *values_byname = NULL;
/*
- * There are very few vendors, and they're looked up only when we
- * read the dictionaries. So it's OK to have a singly linked
- * list here.
+ * For faster HUP's, we cache the stat information for
+ * files we've $INCLUDEd
*/
-static DICT_VENDOR *dictionary_vendors = NULL;
+typedef struct dict_stat_t {
+ struct dict_stat_t *next;
+ char *name;
+ time_t mtime;
+} dict_stat_t;
-static rbtree_t *attributes_byname = NULL;
-static rbtree_t *attributes_byvalue = NULL;
+static char *stat_root_dir = NULL;
+static char *stat_root_file = NULL;
-static rbtree_t *values_byvalue = NULL;
-static rbtree_t *values_byname = NULL;
+static dict_stat_t *stat_head = NULL;
+static dict_stat_t *stat_tail = NULL;
typedef struct value_fixup_t {
char attrstr[40];
+ uint32_t hash;
DICT_VALUE *dval;
struct value_fixup_t *next;
} value_fixup_t;
+
/*
* So VALUEs in the dictionary can have forward references.
*/
};
/*
- * Quick pointers to the base 0..255 attributes.
- *
- * These attributes are referenced a LOT, especially during
- * decoding of the on-the-wire packets. It's useful to keep a
- * cache of their dictionary entries, so looking them up is
- * O(1), instead of O(log(N)). (N==number of dictionary entries...)
+ * Create the hash of the name.
*/
-static DICT_ATTR *base_attributes[256];
+static uint32_t dict_hashname(const char *name)
+{
+ const char *p;
+ char *q;
+ size_t len = 0;
+ char buffer[1024];
+
+ p = name;
+ q = buffer;
+ while (*p && (len < sizeof(buffer))) {
+ if (isalpha(*p)) {
+ *(q++) = tolower((int) *(p++));
+ } else {
+ *(q++) = *(p++);
+ }
+ len++;
+ }
+ return lrad_hash(buffer, len);
+}
+
/*
- * Free the dictionary_attributes and dictionary_values lists.
+ * Free the list of stat buffers
*/
-void dict_free(void)
+static void dict_stat_free(void)
{
- DICT_VENDOR *dvend, *enext;
+ dict_stat_t *this, *next;
+
+ free(stat_root_dir);
+ stat_root_dir = NULL;
+ free(stat_root_file);
+ stat_root_file = NULL;
- memset(base_attributes, 0, sizeof(base_attributes));
+ if (!stat_head) {
+ stat_tail = NULL;
+ return;
+ }
- for (dvend = dictionary_vendors; dvend; dvend = enext) {
- enext = dvend->next;
- free(dvend);
+ for (this = stat_head; this != NULL; this = next) {
+ next = this->next;
+ free(this->name);
+ free(this);
}
- dictionary_vendors = NULL;
+ stat_head = stat_tail = NULL;
+}
+
+
+/*
+ * Add an entry to the list of stat buffers.
+ */
+static void dict_stat_add(const char *name, const struct stat *stat_buf)
+{
+ dict_stat_t *this;
+
+ this = malloc(sizeof(*this));
+ memset(this, 0, sizeof(*this));
+ this->name = strdup(name);
+ this->mtime = stat_buf->st_mtime;
+
+ if (!stat_head) {
+ stat_head = stat_tail = this;
+ } else {
+ stat_tail->next = this;
+ stat_tail = this;
+ }
+}
+
+
+/*
+ * See if any dictionaries have changed. If not, don't
+ * do anything.
+ */
+static int dict_stat_check(const char *root_dir, const char *root_file)
+{
+ struct stat buf;
+ dict_stat_t *this;
+
+ if (!stat_root_dir) return 0;
+ if (!stat_root_file) return 0;
+
+ if (strcmp(root_dir, stat_root_dir) != 0) return 0;
+ if (strcmp(root_file, stat_root_file) != 0) return 0;
+
+ if (!stat_head) return 0; /* changed, reload */
+
+ for (this = stat_head; this != NULL; this = this->next) {
+ if (stat(this->name, &buf) < 0) return 0;
+
+ if (buf.st_mtime != this->mtime) return 0;
+ }
+
+ return 1;
+}
+
+
+/*
+ * Free the dictionary_attributes and dictionary_values lists.
+ */
+void dict_free(void)
+{
/*
- * Free the tree of attributes by name and value.
+ * Free the trees
*/
- rbtree_free(attributes_byname);
- rbtree_free(attributes_byvalue);
+ lrad_hash_table_free(vendors_byname);
+ lrad_hash_table_free(vendors_byvalue);
+ vendors_byname = NULL;
+ vendors_byvalue = NULL;
+
+ lrad_hash_table_free(attributes_byname);
+ lrad_hash_table_free(attributes_byvalue);
attributes_byname = NULL;
attributes_byvalue = NULL;
- rbtree_free(values_byname);
- rbtree_free(values_byvalue);
+ lrad_hash_table_free(values_byname);
+ lrad_hash_table_free(values_byvalue);
values_byname = NULL;
values_byvalue = NULL;
+
+ dict_stat_free();
}
+
/*
* Add vendor to the list.
*/
int dict_addvendor(const char *name, int value)
{
- DICT_VENDOR *vval;
+ size_t length;
+ uint32_t hash;
+ DICT_VENDOR *dv;
if (value >= (1 << 16)) {
librad_log("dict_addvendor: Cannot handle vendor ID larger than 65535");
return -1;
}
- if (strlen(name) > (sizeof(vval->name) -1)) {
+ if ((length = strlen(name)) >= DICT_VENDOR_MAX_NAME_LEN) {
librad_log("dict_addvendor: vendor name too long");
return -1;
}
-
- if ((vval =(DICT_VENDOR *)malloc(sizeof(DICT_VENDOR))) == NULL) {
+
+ if ((dv = malloc(sizeof(*dv) + length)) == NULL) {
librad_log("dict_addvendor: out of memory");
return -1;
}
- strcpy(vval->name, name);
- vval->vendorpec = value;
- /* Insert at front. */
- vval->next = dictionary_vendors;
- dictionary_vendors = vval;
+ hash = dict_hashname(name);
+ strcpy(dv->name, name);
+ dv->vendorpec = value;
+ dv->type = dv->length = 1; /* defaults */
+
+ if (lrad_hash_table_insert(vendors_byname, hash, dv) == 0) {
+ DICT_VENDOR *old_dv;
+
+ old_dv = lrad_hash_table_finddata(vendors_byname, hash);
+ if (!old_dv) {
+ librad_log("dict_addvendor: Failed inserting vendor name %s", name);
+ return -1;
+ }
+ if (old_dv->vendorpec != dv->vendorpec) {
+ librad_log("dict_addvendor: Duplicate vendor name %s", name);
+ return -1;
+ }
+
+ /*
+ * Already inserted. Discard the duplicate entry.
+ */
+ free(dv);
+ return 0;
+ }
+
+ /*
+ * Insert the SAME pointer (not free'd when this tree is
+ * deleted), into another tree.
+ *
+ * If the newly inserted entry is a duplicate of an existing
+ * entry, then the old entry is tossed, and the new one
+ * replaces it. This behaviour is configured in the
+ * lrad_hash_table_create() function.
+ *
+ * We want this behaviour because we want OLD names for
+ * the attributes to be read from the configuration
+ * files, but when we're printing them, (and looking up
+ * by value) we want to use the NEW name.
+ */
+ lrad_hash_table_insert(vendors_byvalue, dv->vendorpec, dv);
return 0;
}
ATTR_FLAGS flags)
{
static int max_attr = 0;
+ uint32_t hash;
DICT_ATTR *attr;
if (strlen(name) > (sizeof(attr->name) -1)) {
* and use that.
*/
if (value == -1) {
- attr = dict_attrbyname(name);
- if (attr != NULL) {
+ if (dict_attrbyname(name)) {
return 0; /* exists, don't add it again */
}
}
}
+ if (value < 0) {
+ librad_log("dict_addattr: ATTRIBUTE has invalid number (less than zero)");
+ return -1;
+ }
+
if (value >= 65536) {
- librad_log("dict_addattr: ATTRIBUTE has invalid number.");
+ librad_log("dict_addattr: ATTRIBUTE has invalid number (larger than 65535).");
return -1;
}
+ if (vendor) {
+ DICT_VENDOR *dv = dict_vendorbyvalue(vendor);
+
+ /*
+ * If the vendor isn't defined, die/
+ */
+ if (!dv) {
+ librad_log("dict_addattr: Unknown vendor");
+ return -1;
+ }
+
+ /*
+ * With a few exceptions, attributes can only be
+ * 1..255. The check above catches the less than
+ * zero case.
+ */
+ if ((dv->type == 1) && (value >= 256)) {
+ librad_log("dict_addattr: ATTRIBUTE has invalid number (larger than 255).");
+ return -1;
+ } /* else 256..65535 are allowed */
+ }
+
/*
* Create a new attribute for the list
*/
- if ((attr = (DICT_ATTR *)malloc(sizeof(DICT_ATTR))) == NULL) {
+ if ((attr = malloc(sizeof(*attr))) == NULL) {
librad_log("dict_addattr: out of memory");
return -1;
}
+
+ hash = dict_hashname(name);
strcpy(attr->name, name);
attr->attr = value;
+ attr->attr |= (vendor << 16); /* FIXME: hack */
attr->type = type;
attr->flags = flags;
+ attr->vendor = vendor;
- if (vendor) attr->attr |= (vendor << 16);
/*
* Insert the attribute, only if it's not a duplicate.
*/
- if (rbtree_insert(attributes_byname, attr) == 0) {
+ if (lrad_hash_table_insert(attributes_byname, hash, attr) == 0) {
DICT_ATTR *a;
/*
* If the attribute has identical number, then
* ignore the duplicate.
*/
- a = rbtree_finddata(attributes_byname, attr);
+ a = lrad_hash_table_finddata(attributes_byname, hash);
if (a && (strcasecmp(a->name, attr->name) == 0)) {
if (a->attr != attr->attr) {
librad_log("dict_addattr: Duplicate attribute name %s", name);
}
/*
- * Same name, same attr, maybe the
- * flags and/or type is different.
- * Let the new value over-ride the
- * old one.
+ * Same name, same vendor, same attr,
+ * maybe the flags and/or type is
+ * different. Let the new value
+ * over-ride the old one.
*/
}
}
- if ((attr->attr >= 0) && (attr->attr < 256)) {
- /*
- * If it's an on-the-wire base attribute,
- * then keep a quick reference to it, for speed.
- */
- base_attributes[attr->attr] = attr;
- }
-
/*
* Insert the SAME pointer (not free'd when this tree is
* deleted), into another tree.
* If the newly inserted entry is a duplicate of an existing
* entry, then the old entry is tossed, and the new one
* replaces it. This behaviour is configured in the
- * rbtree_create() function.
+ * lrad_hash_table_create() function.
*
* We want this behaviour because we want OLD names for
* the attributes to be read from the configuration
* files, but when we're printing them, (and looking up
* by value) we want to use the NEW name.
*/
- rbtree_insert(attributes_byvalue, attr);
+ lrad_hash_table_insert(attributes_byvalue, (uint32_t) attr->attr, attr);
return 0;
}
+
/*
* Add a value for an attribute to the dictionary.
*/
-int dict_addvalue(const char *namestr, char *attrstr, int value)
+int dict_addvalue(const char *namestr, const char *attrstr, int value)
{
+ size_t length;
DICT_ATTR *dattr;
+ uint32_t hash;
DICT_VALUE *dval;
- if (strlen(namestr) > (sizeof(dval->name) -1)) {
+ if ((length = strlen(namestr)) >= DICT_VALUE_MAX_NAME_LEN) {
librad_log("dict_addvalue: value name too long");
return -1;
}
- if ((dval = (DICT_VALUE *)malloc(sizeof(DICT_VALUE))) == NULL) {
+ if ((dval = malloc(sizeof(*dval) + length)) == NULL) {
librad_log("dict_addvalue: out of memory");
return -1;
}
memset(dval, 0, sizeof(*dval));
+ hash = dict_hashname(namestr);
strcpy(dval->name, namestr);
dval->value = value;
dattr = dict_attrbyname(attrstr);
if (dattr) {
dval->attr = dattr->attr;
+ hash = lrad_hash_update(&dval->attr, sizeof(dval->attr), hash);
} else {
value_fixup_t *fixup;
memset(fixup, 0, sizeof(*fixup));
strNcpy(fixup->attrstr, attrstr, sizeof(fixup->attrstr));
+ fixup->hash = hash;
fixup->dval = dval;
/*
/*
* Add the value into the dictionary.
*/
- if (rbtree_insert(values_byname, dval) == 0) {
+ if (lrad_hash_table_insert(values_byname, hash, dval) == 0) {
if (dattr) {
- DICT_VALUE *dup;
+ DICT_VALUE *old;
/*
* Suppress duplicates with the same
* name and value. There are lots in
* dictionary.ascend.
*/
- dup = dict_valbyname(dattr->attr, namestr);
- if (dup && (dup->value == dval->value)) {
+ old = dict_valbyname(dattr->attr, namestr);
+ if (old && (old->value == dval->value)) {
free(dval);
return 0;
}
librad_log("dict_addvalue: Duplicate value name %s for attribute %s", namestr, attrstr);
return -1;
}
- rbtree_insert(values_byvalue, dval);
+
+ /*
+ * There are multiple VALUE's, keyed by attribute, so we
+ * take care of that here.
+ */
+ hash = dval->attr;
+ hash = lrad_hash_update(&dval->value, sizeof(dval->value), hash);
+ lrad_hash_table_insert(values_byvalue, hash, dval);
return 0;
}
* Process the ATTRIBUTE command
*/
static int process_attribute(const char* fn, const int line,
- const int block_vendor, const char* data)
+ const int block_vendor, char **argv,
+ int argc)
{
- int vendor;
- char namestr[256];
- char valstr[256];
- char typestr[256];
- char optstr[256];
+ int vendor = 0;
int value;
int type;
char *s, *c;
ATTR_FLAGS flags;
- vendor = 0;
- optstr[0] = 0;
- if(sscanf(data, "%s%s%s%s", namestr, valstr, typestr, optstr) < 3) {
+ if ((argc < 3) || (argc > 4)) {
librad_log("dict_init: %s[%d]: invalid ATTRIBUTE line",
fn, line);
return -1;
/*
* Validate all entries
*/
- if (!isdigit((int) *valstr)) {
+ if (!isdigit((int) argv[1][0])) {
librad_log("dict_init: %s[%d]: invalid value", fn, line);
return -1;
}
- if (valstr[0] != '0')
- value = atoi(valstr);
- else
- sscanf(valstr, "%i", &value);
+ sscanf(argv[1], "%i", &value);
/*
* find the type of the attribute.
*/
- type = lrad_str2int(type_table, typestr, -1);
+ type = lrad_str2int(type_table, argv[2], -1);
if (type < 0) {
librad_log("dict_init: %s[%d]: invalid type \"%s\"",
- fn, line, typestr);
+ fn, line, argv[2]);
return -1;
}
/*
- * Ignore comments
- */
- if (optstr[0] == '#') optstr[0] = '\0';
-
- /*
* Only look up the vendor if the string
* is non-empty.
*/
-
memset(&flags, 0, sizeof(flags));
- s = strtok(optstr, ",");
- while(s) {
- if (strcmp(s, "has_tag") == 0 ||
- strcmp(s, "has_tag=1") == 0) {
- /* Boolean flag, means this is a
- tagged attribute */
- flags.has_tag = 1;
- }
- else if (strncmp(s, "len+=", 5) == 0 ||
- strncmp(s, "len-=", 5) == 0) {
- /* Length difference, to accomodate
- braindead NASes & their vendors */
- flags.len_disp = strtol(s + 5, &c, 0);
- if (*c) {
- librad_log("dict_init: %s[%d] invalid option %s",
- fn, line, s);
- return -1;
- }
- if (s[3] == '-') {
- flags.len_disp = -flags.len_disp;
- }
- }
- else if (strncmp(s, "encrypt=", 8) == 0) {
- /* Encryption method, defaults to 0 (none).
- Currently valid is just type 2,
- Tunnel-Password style, which can only
- be applied to strings. */
- flags.encrypt = strtol(s + 8, &c, 0);
- if (*c) {
- librad_log( "dict_init: %s[%d] invalid option %s",
- fn, line, s);
- return -1;
- }
- }
- else {
- /* Must be a vendor 'flag'... */
- if (strncmp(s, "vendor=", 7) == 0) {
- /* New format */
- s += 7;
- }
-
- vendor = dict_vendorbyname(s);
- if (!vendor) {
- librad_log( "dict_init: %s[%d]: unknown vendor %s",
- fn, line, optstr);
- return -1;
- }
- if (block_vendor && optstr[0] &&
- (block_vendor != vendor)) {
- librad_log("dict_init: %s[%d]: mismatched vendor %s within BEGIN-VENDOR/END-VENDOR block",
- fn, line, optstr);
- return -1;
- }
+ if (argc == 4) {
+ s = strtok(argv[3], ",");
+ while (s) {
+ if (strcmp(s, "has_tag") == 0 ||
+ strcmp(s, "has_tag=1") == 0) {
+ /* Boolean flag, means this is a
+ tagged attribute */
+ flags.has_tag = 1;
+
+ } else if (strncmp(s, "encrypt=", 8) == 0) {
+ /* Encryption method, defaults to 0 (none).
+ Currently valid is just type 2,
+ Tunnel-Password style, which can only
+ be applied to strings. */
+ flags.encrypt = strtol(s + 8, &c, 0);
+ if (*c) {
+ librad_log( "dict_init: %s[%d] invalid option %s",
+ fn, line, s);
+ return -1;
+ }
+ } else {
+ /* Must be a vendor 'flag'... */
+ if (strncmp(s, "vendor=", 7) == 0) {
+ /* New format */
+ s += 7;
+ }
+
+ vendor = dict_vendorbyname(s);
+ if (!vendor) {
+ librad_log( "dict_init: %s[%d]: unknown vendor %s",
+ fn, line, s);
+ return -1;
+ }
+ if (block_vendor && argv[3][0] &&
+ (block_vendor != vendor)) {
+ librad_log("dict_init: %s[%d]: mismatched vendor %s within BEGIN-VENDOR/END-VENDOR block",
+ fn, line, argv[3]);
+ return -1;
+ }
+ }
+ s = strtok(NULL, ",");
}
- s = strtok(NULL, ",");
}
if (block_vendor) vendor = block_vendor;
- if (dict_addattr(namestr, vendor, type, value, flags) < 0) {
+ /*
+ * Special checks for tags, they make our life much more
+ * difficult.
+ */
+ if (flags.has_tag) {
+ /*
+ * VSA's can't be tagged.
+ */
+ if (vendor) {
+ librad_log("dict_init: %s[%d]: Vendor attributes cannot be tagged.",
+ fn, line);
+ return -1;
+ }
+
+ /*
+ * Only string, octets, and integer can be tagged.
+ */
+ switch (type) {
+ case PW_TYPE_STRING:
+ case PW_TYPE_INTEGER:
+ break;
+
+ default:
+ librad_log("dict_init: %s[%d]: Attributes of type %s cannot be tagged.",
+ fn, line,
+ lrad_int2str(type_table, type, "?Unknown?"));
+ return -1;
+
+ }
+ }
+
+ /*
+ * Add it in.
+ */
+ if (dict_addattr(argv[0], vendor, type, value, flags) < 0) {
librad_log("dict_init: %s[%d]: %s",
fn, line, librad_errstr);
return -1;
/*
* Process the VALUE command
*/
-static int process_value(const char* fn, const int line, const char* data)
+static int process_value(const char* fn, const int line, char **argv,
+ int argc)
{
- char namestr[256];
- char valstr[256];
- char attrstr[256];
int value;
- if (sscanf(data, "%s%s%s", attrstr, namestr, valstr) != 3) {
+ if (argc != 3) {
librad_log("dict_init: %s[%d]: invalid VALUE line",
fn, line);
return -1;
/*
* For Compatibility, skip "Server-Config"
*/
- if (strcasecmp(attrstr, "Server-Config") == 0)
+ if (strcasecmp(argv[0], "Server-Config") == 0)
return 0;
/*
* Validate all entries
*/
- if (!isdigit((int) *valstr)) {
+ if (!isdigit((int) argv[2][0])) {
librad_log("dict_init: %s[%d]: invalid value",
fn, line);
return -1;
}
- if (valstr[0] != '0')
- value = atoi(valstr);
- else
- sscanf(valstr, "%i", &value);
+ sscanf(argv[2], "%i", &value);
- if (dict_addvalue(namestr, attrstr, value) < 0) {
+ /*
+ * valuepair.c will get excited when creating attributes,
+ * if it sees values which look like integers, so we can't
+ * use them here.
+ */
+ if (isdigit(argv[1][0])) {
+ librad_log("dict_init: %s[%d]: Names for VALUEs cannot start with a digit.",
+ fn, line);
+ }
+
+ if (dict_addvalue(argv[1], argv[0], value) < 0) {
librad_log("dict_init: %s[%d]: %s",
fn, line, librad_errstr);
return -1;
/*
* Process the VENDOR command
*/
-static int process_vendor(const char* fn, const int line, const char* data)
+static int process_vendor(const char* fn, const int line, char **argv,
+ int argc)
{
- char valstr[256];
- char attrstr[256];
int value;
+ const char *format = NULL;
- if (sscanf(data, "%s%s", attrstr, valstr) != 2) {
- librad_log(
- "dict_init: %s[%d] invalid VENDOR entry",
- fn, line);
+ if ((argc < 2) || (argc > 3)) {
+ librad_log( "dict_init: %s[%d] invalid VENDOR entry",
+ fn, line);
return -1;
}
/*
* Validate all entries
*/
- if (!isdigit((int) *valstr)) {
+ if (!isdigit((int) argv[1][0])) {
librad_log("dict_init: %s[%d]: invalid value",
fn, line);
return -1;
}
- value = atoi(valstr);
+ value = atoi(argv[1]);
/* Create a new VENDOR entry for the list */
- if (dict_addvendor(attrstr, value) < 0) {
+ if (dict_addvendor(argv[0], value) < 0) {
librad_log("dict_init: %s[%d]: %s",
fn, line, librad_errstr);
return -1;
}
+ /*
+ * Look for a format statement
+ */
+ if (argc == 3) {
+ format = argv[2];
+
+ } else if (value == VENDORPEC_USR) { /* catch dictionary screw-ups */
+ format = "format=4,0";
+
+ } else if (value == VENDORPEC_LUCENT) {
+ format = "format=2,1";
+
+ } else if (value == VENDORPEC_STARENT) {
+ format = "format=2,2";
+
+ } /* else no fixups to do */
+
+ if (format) {
+ int type, length;
+ const char *p;
+ DICT_VENDOR *dv;
+
+ if (strncasecmp(format, "format=", 7) != 0) {
+ librad_log("dict_init: %s[%d]: Invalid format for VENDOR. Expected \"format=\", got \"%s\"",
+ fn, line, format);
+ return -1;
+ }
+
+ p = format + 7;
+ if ((strlen(p) != 3) ||
+ !isdigit((int) p[0]) ||
+ (p[1] != ',') ||
+ !isdigit((int) p[2])) {
+ librad_log("dict_init: %s[%d]: Invalid format for VENDOR. Expected text like \"1,1\", got \"%s\"",
+ fn, line, p);
+ return -1;
+ }
+
+ type = (int) (p[0] - '0');
+ length = (int) (p[2] - '0');
+
+ dv = dict_vendorbyvalue(value);
+ if (!dv) {
+ librad_log("dict_init: %s[%d]: Failed adding format for VENDOR",
+ fn, line);
+ return -1;
+ }
+
+ if ((type != 1) && (type != 2) && (type != 4)) {
+ librad_log("dict_init: %s[%d]: invalid type value %d for VENDOR",
+ fn, line, type);
+ return -1;
+ }
+
+ if ((length != 0) && (length != 1) && (length != 2)) {
+ librad_log("dict_init: %s[%d]: invalid length value %d for VENDOR",
+ fn, line, length);
+ return -1;
+ }
+
+ dv->type = type;
+ dv->length = length;
+ }
+
return 0;
}
+/*
+ * String split routine. Splits an input string IN PLACE
+ * into pieces, based on spaces.
+ */
+static int str2argv(char *str, char **argv, int max_argc)
+{
+ int argc = 0;
+
+ while (*str) {
+ if (argc >= max_argc) return argc;
+
+ /*
+ * Chop out comments early.
+ */
+ if (*str == '#') {
+ *str = '\0';
+ break;
+ }
+
+ while ((*str == ' ') ||
+ (*str == '\t') ||
+ (*str == '\r') ||
+ (*str == '\n')) *(str++) = '\0';
+
+ if (!*str) return argc;
+
+ argv[argc] = str;
+ argc++;
+
+ while (*str &&
+ (*str != ' ') &&
+ (*str != '\t') &&
+ (*str != '\r') &&
+ (*str != '\n')) str++;
+ }
+
+ return argc;
+}
+
+#define MAX_ARGV (16)
/*
* Initialize the dictionary.
FILE *fp;
char dirtmp[256];
char buf[256];
- char optstr[256];
char *p;
- char *keyword;
- char *data;
int line = 0;
int vendor;
int block_vendor;
+ struct stat statbuf;
+ char *argv[MAX_ARGV];
+ int argc;
if (strlen(fn) >= sizeof(dirtmp) / 2 ||
strlen(dir) >= sizeof(dirtmp) / 2) {
return -1;
}
+ stat(fn, &statbuf); /* fopen() guarantees this will succeed */
+ dict_stat_add(fn, &statbuf);
+
+ /*
+ * Seed the random pool with data.
+ */
+ lrad_rand_seed(&statbuf, sizeof(statbuf));
+
block_vendor = 0;
while (fgets(buf, sizeof(buf), fp) != NULL) {
p = strchr(buf, '#');
if (p) *p = '\0';
- keyword = strtok(buf, " \t\r\n");
- if (keyword == NULL) {
- continue;
- }
+ argc = str2argv(buf, argv, MAX_ARGV);
+ if (argc == 0) continue;
- data = strtok(NULL, "\r\n");
- if (data == NULL || data[0] == 0) {
- librad_log("dict_init: %s[%d]: invalid entry for keyword %s",
- fn, line, keyword);
+ if (argc == 1) {
+ librad_log( "dict_init: %s[%d] invalid entry",
+ fn, line);
fclose(fp);
return -1;
}
+ if (0) {
+ int i;
+
+ fprintf(stderr, "ARGC = %d\n",argc);
+ for (i = 0; i < argc; i++) {
+ fprintf(stderr, "\t%s\n", argv[i]);
+ }
+ }
+
/*
* See if we need to import another dictionary.
*/
- if (strcasecmp(keyword, "$INCLUDE") == 0) {
- p = strtok(data, " \t");
- if (my_dict_init(dir, data, fn, line) < 0) {
+ if (strcasecmp(argv[0], "$INCLUDE") == 0) {
+ if (my_dict_init(dir, argv[1], fn, line) < 0) {
fclose(fp);
return -1;
}
/*
* Perhaps this is an attribute.
*/
- if (strcasecmp(keyword, "ATTRIBUTE") == 0) {
- if (process_attribute(fn, line, block_vendor, data) == -1) {
+ if (strcasecmp(argv[0], "ATTRIBUTE") == 0) {
+ if (process_attribute(fn, line, block_vendor,
+ argv + 1, argc - 1) == -1) {
fclose(fp);
return -1;
}
/*
* Process VALUE lines.
*/
- if (strcasecmp(keyword, "VALUE") == 0) {
- if (process_value(fn, line, data) == -1) {
+ if (strcasecmp(argv[0], "VALUE") == 0) {
+ if (process_value(fn, line,
+ argv + 1, argc - 1) == -1) {
fclose(fp);
return -1;
}
/*
* Process VENDOR lines.
*/
- if (strcasecmp(keyword, "VENDOR") == 0) {
- if (process_vendor(fn, line, data) == -1) {
+ if (strcasecmp(argv[0], "VENDOR") == 0) {
+ if (process_vendor(fn, line,
+ argv + 1, argc - 1) == -1) {
fclose(fp);
return -1;
}
continue;
}
- if (strcasecmp(keyword, "BEGIN-VENDOR") == 0) {
- optstr[0] = 0;
- if (sscanf(data, "%s", optstr) != 1) {
+ if (strcasecmp(argv[0], "BEGIN-VENDOR") == 0) {
+ if (argc != 2) {
librad_log(
"dict_init: %s[%d] invalid BEGIN-VENDOR entry",
fn, line);
return -1;
}
- vendor = dict_vendorbyname(optstr);
+ vendor = dict_vendorbyname(argv[1]);
if (!vendor) {
librad_log(
"dict_init: %s[%d]: unknown vendor %s",
- fn, line, optstr);
+ fn, line, argv[1]);
fclose(fp);
return -1;
}
continue;
} /* BEGIN-VENDOR */
- if (strcasecmp(keyword, "END-VENDOR") == 0) {
- optstr[0] = 0;
- if (sscanf(data, "%s", optstr) != 1) {
+ if (strcasecmp(argv[0], "END-VENDOR") == 0) {
+ if (argc != 2) {
librad_log(
"dict_init: %s[%d] invalid END-VENDOR entry",
fn, line);
return -1;
}
- vendor = dict_vendorbyname(optstr);
+ vendor = dict_vendorbyname(argv[1]);
if (!vendor) {
librad_log(
"dict_init: %s[%d]: unknown vendor %s",
- fn, line, optstr);
+ fn, line, argv[1]);
fclose(fp);
return -1;
}
if (vendor != block_vendor) {
librad_log(
"dict_init: %s[%d]: END-VENDOR %s does not match any previous BEGIN-VENDOR",
- fn, line, optstr);
+ fn, line, argv[1]);
fclose(fp);
return -1;
}
*/
librad_log(
"dict_init: %s[%d] invalid keyword \"%s\"",
- fn, line, keyword);
+ fn, line, argv[0]);
fclose(fp);
return -1;
}
}
/*
- * Callbacks for red-black trees.
- */
-static int attrname_cmp(const void *a, const void *b)
-{
- return strcasecmp(((const DICT_ATTR *)a)->name,
- ((const DICT_ATTR *)b)->name);
-}
-
-/*
- * Return: < 0 if a < b,
- * == 0 if a == b
- */
-static int attrvalue_cmp(const void *a, const void *b)
-{
- return (((const DICT_ATTR *)a)->attr -
- ((const DICT_ATTR *)b)->attr);
-}
-
-/*
- * Compare values by name, keying off of the attribute number,
- * and then the value name.
- */
-static int valuename_cmp(const void *a, const void *b)
-{
- int rcode;
- rcode = (((const DICT_VALUE *)a)->attr -
- ((const DICT_VALUE *)b)->attr);
- if (rcode != 0) return rcode;
-
-return strcasecmp(((const DICT_VALUE *)a)->name,
- ((const DICT_VALUE *)b)->name);
-}
-
-/*
- * Compare values by value, keying off of the attribute number,
- * and then the value number.
- */
-static int valuevalue_cmp(const void *a, const void *b)
-{
- int rcode;
- rcode = (((const DICT_VALUE *)a)->attr -
- ((const DICT_VALUE *)b)->attr);
- if (rcode != 0) return rcode;
-
- return (((const DICT_VALUE *)a)->value -
- ((const DICT_VALUE *)b)->value);
-}
-
-/*
* Initialize the directory, then fix the attr member of
* all attributes.
*/
int dict_init(const char *dir, const char *fn)
{
+ /*
+ * Check if we need to change anything. If not, don't do
+ * anything.
+ */
+ if (dict_stat_check(dir, fn)) {
+ return 0;
+ }
+
+ /*
+ * Free the dictionaries, and the stat cache.
+ */
dict_free();
+ stat_root_dir = strdup(dir);
+ stat_root_file = strdup(fn);
+
+ /*
+ * Create the tree of vendor by name. There MAY NOT
+ * be multiple vendors of the same name.
+ *
+ * Each vendor is malloc'd, so the free function is free.
+ */
+ vendors_byname = lrad_hash_table_create(8, free, 0);
+ if (!vendors_byname) {
+ return -1;
+ }
+
+ /*
+ * Create the tree of vendors by value. There MAY
+ * be vendors of the same value. If there are, we
+ * pick the latest one.
+ */
+ vendors_byvalue = lrad_hash_table_create(8, NULL, 1);
+ if (!vendors_byvalue) {
+ return -1;
+ }
/*
* Create the tree of attributes by name. There MAY NOT
*
* Each attribute is malloc'd, so the free function is free.
*/
- attributes_byname = rbtree_create(attrname_cmp, free, 0);
+ attributes_byname = lrad_hash_table_create(11, free, 0);
if (!attributes_byname) {
return -1;
}
* be attributes of the same value. If there are, we
* pick the latest one.
*/
- attributes_byvalue = rbtree_create(attrvalue_cmp, NULL, 1);
+ attributes_byvalue = lrad_hash_table_create(11, NULL, 1);
if (!attributes_byvalue) {
return -1;
}
- values_byname = rbtree_create(valuename_cmp, free, 0);
+ values_byname = lrad_hash_table_create(11, free, 0);
if (!values_byname) {
return -1;
}
- values_byvalue = rbtree_create(valuevalue_cmp, NULL, 1);
+ values_byvalue = lrad_hash_table_create(11, NULL, 1);
if (!values_byvalue) {
return -1;
}
return -1;
if (value_fixup) {
+ uint32_t hash;
DICT_ATTR *a;
value_fixup_t *this, *next;
/*
* Add the value into the dictionary.
*/
- if (rbtree_insert(values_byname, this->dval) == 0) {
+ hash = lrad_hash_update(&this->dval->attr,
+ sizeof(this->dval->attr),
+ this->hash);
+ if (lrad_hash_table_insert(values_byname,
+ hash, this->dval) == 0) {
librad_log("dict_addvalue: Duplicate value name %s for attribute %s", this->dval->name, a->name);
return -1;
}
* prefer the new name when printing
* values.
*/
- if (!rbtree_find(values_byvalue, this->dval)) {
- rbtree_insert(values_byvalue, this->dval);
+ hash = (uint32_t) this->dval->attr;
+ hash = lrad_hash_update(&this->dval->value,
+ sizeof(this->dval->value),
+ hash);
+ if (!lrad_hash_table_finddata(values_byvalue, hash)) {
+ lrad_hash_table_insert(values_byvalue,
+ hash, this->dval);
}
free(this);
*/
DICT_ATTR *dict_attrbyvalue(int val)
{
- /*
- * If it's an on-the-wire base attribute, return
- * the cached value for it.
- */
- if ((val >= 0) && (val < 256)) {
- return base_attributes[val];
-
- } else {
- DICT_ATTR myattr;
-
- myattr.attr = val;
- return rbtree_finddata(attributes_byvalue, &myattr);
- }
-
- return NULL; /* never reached, but useful */
+ return lrad_hash_table_finddata(attributes_byvalue, (uint32_t) val);
}
/*
*/
DICT_ATTR *dict_attrbyname(const char *name)
{
- DICT_ATTR myattr;
-
- strNcpy(myattr.name, name, sizeof(myattr.name));
-
- return rbtree_finddata(attributes_byname, &myattr);
+ return lrad_hash_table_finddata(attributes_byname,
+ dict_hashname(name));
}
/*
*/
DICT_VALUE *dict_valbyattr(int attr, int val)
{
- DICT_VALUE myval;
+ uint32_t hash = attr;
- myval.attr = attr;
- myval.value = val;
+ hash = lrad_hash_update(&val, sizeof(val), hash);
- return rbtree_finddata(values_byvalue, &myval);
+ return lrad_hash_table_finddata(values_byvalue, hash);
}
/*
- * Get a value by its name.
- * If you pass an actual attr, it will try to match it.
- * If you just want it to return on the first match,
- * send it 0 as the attr. I hope this works the way it
- * seems to. :) --kph
+ * Get a value by its name, keyed off of an attribute.
*/
DICT_VALUE *dict_valbyname(int attr, const char *name)
{
- DICT_VALUE myval;
+ uint32_t hash;
- myval.attr = attr;
- strNcpy(myval.name, name, sizeof(myval.name));
+ hash = dict_hashname(name);
+ hash = lrad_hash_update(&attr, sizeof(&attr), hash);
- return rbtree_finddata(values_byname, &myval);
+ return lrad_hash_table_finddata(values_byname, hash);
}
/*
* Get the vendor PEC based on the vendor name
+ *
+ * This is efficient only for small numbers of vendors.
*/
int dict_vendorbyname(const char *name)
{
- DICT_VENDOR *v;
+ uint32_t hash;
+ DICT_VENDOR *dv;
- /*
- * Find the vendor, if any.
- */
- for (v = dictionary_vendors; v; v = v->next) {
- if (strcasecmp(name, v->name) == 0) {
- return v->vendorpec;
- }
- }
+ hash = dict_hashname(name);
+
+ dv = lrad_hash_table_finddata(vendors_byname, hash);
+ if (!dv) return 0;
- return 0;
+ return dv->vendorpec;
}
/*
*/
DICT_VENDOR *dict_vendorbyvalue(int vendor)
{
- DICT_VENDOR *v;
-
- /*
- * Find the vendor, if any.
- */
- for (v = dictionary_vendors; v; v = v->next) {
- if (vendor == v->vendorpec) {
- return v;
- }
- }
-
- return NULL;
-
+ return lrad_hash_table_finddata(vendors_byvalue, (uint32_t) vendor);
}
} radius_packet_t;
static lrad_randctx lrad_rand_pool; /* across multiple calls */
-static int lrad_pool_initialized = 0;
+static volatile int lrad_rand_index = -1;
+static unsigned int salt_offset = 0;
static const char *packet_codes[] = {
"",
"IP-Address-Release"
};
+
+#define AUTH_PASS_LEN (AUTH_VECTOR_LEN)
+/*************************************************************************
+ *
+ * Function: make_secret
+ *
+ * Purpose: Build an encrypted secret value to return in a reply
+ * packet. The secret is hidden by xoring with a MD5 digest
+ * created from the shared secret and the authentication
+ * vector. We put them into MD5 in the reverse order from
+ * that used when encrypting passwords to RADIUS.
+ *
+ *************************************************************************/
+static void make_secret(uint8_t *digest, const uint8_t *vector,
+ const char *secret, const uint8_t *value)
+{
+ MD5_CTX context;
+ int i;
+
+ MD5Init(&context);
+ MD5Update(&context, vector, AUTH_VECTOR_LEN);
+ MD5Update(&context, secret, strlen(secret));
+ MD5Final(digest, &context);
+
+ for ( i = 0; i < AUTH_VECTOR_LEN; i++ ) {
+ digest[i] ^= value[i];
+ }
+}
+
+#define MAX_PASS_LEN (128)
+static void make_passwd(uint8_t *output, int *outlen,
+ const uint8_t *input, int inlen,
+ const char *secret, const uint8_t *vector)
+{
+ MD5_CTX context, old;
+ uint8_t digest[AUTH_VECTOR_LEN];
+ uint8_t passwd[MAX_PASS_LEN];
+ int i, n;
+ int len;
+
+ /*
+ * If the length is zero, round it up.
+ */
+ len = inlen;
+ if (len == 0) {
+ len = AUTH_PASS_LEN;
+ }
+ else if (len > MAX_PASS_LEN) len = MAX_PASS_LEN;
+
+ else if ((len & 0x0f) != 0) {
+ len += 0x0f;
+ len &= ~0x0f;
+ }
+ *outlen = len;
+
+ memcpy(passwd, input, len);
+ memset(passwd + len, 0, sizeof(passwd) - len);
+
+ MD5Init(&context);
+ MD5Update(&context, secret, strlen(secret));
+ old = context;
+
+ /*
+ * Do first pass.
+ */
+ MD5Update(&context, vector, AUTH_PASS_LEN);
+
+ for (n = 0; n < len; n += AUTH_PASS_LEN) {
+ if (n > 0) {
+ context = old;
+ MD5Update(&context,
+ passwd + n - AUTH_PASS_LEN,
+ AUTH_PASS_LEN);
+ }
+
+ MD5Final(digest, &context);
+ for (i = 0; i < AUTH_PASS_LEN; i++) {
+ passwd[i + n] ^= digest[i];
+ }
+ }
+
+ memcpy(output, passwd, len);
+}
+
+static void make_tunnel_passwd(uint8_t *output, int *outlen,
+ const uint8_t *input, int inlen,
+ const char *secret, const uint8_t *vector)
+{
+ MD5_CTX context, old;
+ uint8_t digest[AUTH_VECTOR_LEN];
+ uint8_t passwd[AUTH_PASS_LEN + AUTH_VECTOR_LEN];
+ int i, n;
+ int len;
+
+ /*
+ * Length of the encrypted data is password length plus
+ * one byte for the length of the password.
+ */
+ len = inlen + 1;
+ if (len > AUTH_PASS_LEN) len = AUTH_PASS_LEN;
+ else if ((len & 0x0f) != 0) {
+ len += 0x0f;
+ len &= ~0x0f;
+ }
+ *outlen = len + 2; /* account for the salt */
+
+ /*
+ * Copy the password over.
+ */
+ memcpy(passwd + 3, input, inlen);
+ memset(passwd + 3 + inlen, 0, sizeof(passwd) - 3 - inlen);
+
+ /*
+ * Generate salt. The RFC's say:
+ *
+ * The high bit of salt[0] must be set, each salt in a
+ * packet should be unique, and they should be random
+ *
+ * So, we set the high bit, add in a counter, and then
+ * add in some CSPRNG data. should be OK..
+ */
+ passwd[0] = (0x80 | ( ((salt_offset++) & 0x0f) << 3) |
+ (lrad_rand() & 0x07));
+ passwd[1] = lrad_rand();
+ passwd[2] = inlen; /* length of the password string */
+
+ MD5Init(&context);
+ MD5Update(&context, secret, strlen(secret));
+ old = context;
+
+ MD5Update(&context, vector, AUTH_VECTOR_LEN);
+ MD5Update(&context, &passwd[0], 2);
+
+ for (n = 0; n < len; n += AUTH_PASS_LEN) {
+ if (n > 0) {
+ context = old;
+ MD5Update(&context,
+ passwd + 2 + n - AUTH_PASS_LEN,
+ AUTH_PASS_LEN);
+ }
+
+ MD5Final(digest, &context);
+ for (i = 0; i < AUTH_PASS_LEN; i++) {
+ passwd[i + 2 + n] ^= digest[i];
+ }
+ }
+ memcpy(output, passwd, len + 2);
+}
+
+/*
+ * Parse a data structure into a RADIUS attribute.
+ */
+int rad_vp2attr(const RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret, const VALUE_PAIR *vp, uint8_t *ptr)
+{
+ int vendorcode;
+ int offset, len, total_length;
+ uint32_t lvalue;
+ uint8_t *length_ptr, *vsa_length_ptr;
+ const uint8_t *data = NULL;
+ uint8_t array[4];
+
+ vendorcode = total_length = 0;
+ length_ptr = vsa_length_ptr = NULL;
+
+ /*
+ * For interoperability, always put vendor attributes
+ * into their own VSA.
+ */
+ if ((vendorcode = VENDOR(vp->attribute)) != 0) {
+ /*
+ * Build a VSA header.
+ */
+ *ptr++ = PW_VENDOR_SPECIFIC;
+ vsa_length_ptr = ptr;
+ *ptr++ = 6;
+ lvalue = htonl(vendorcode);
+ memcpy(ptr, &lvalue, 4);
+ ptr += 4;
+ total_length += 6;
+
+ if (vendorcode == VENDORPEC_USR) {
+ lvalue = htonl(vp->attribute & 0xFFFF);
+ memcpy(ptr, &lvalue, 4);
+
+ length_ptr = vsa_length_ptr;
+
+ total_length += 4;
+ *length_ptr += 4;
+ ptr += 4;
+
+ /*
+ * We don't have two different lengths.
+ */
+ vsa_length_ptr = NULL;
+
+ } else if (vendorcode == VENDORPEC_LUCENT) {
+ /*
+ * 16-bit attribute, 8-bit length
+ */
+ *ptr++ = ((vp->attribute >> 8) & 0xFF);
+ *ptr++ = (vp->attribute & 0xFF);
+ length_ptr = ptr;
+ *vsa_length_ptr += 3;
+ *ptr++ = 3;
+ total_length += 3;
+
+ } else if (vendorcode == VENDORPEC_STARENT) {
+ /*
+ * 16-bit attribute, 16-bit length
+ * with the upper 8 bits of the length
+ * always zero!
+ */
+ *ptr++ = ((vp->attribute >> 8) & 0xFF);
+ *ptr++ = (vp->attribute & 0xFF);
+ *ptr++ = 0;
+ length_ptr = ptr;
+ *vsa_length_ptr += 4;
+ *ptr++ = 4;
+ total_length += 4;
+ } else {
+ /*
+ * All other VSA's are encoded the same
+ * as RFC attributes.
+ */
+ *vsa_length_ptr += 2;
+ goto rfc;
+ }
+ } else {
+ rfc:
+ /*
+ * All other attributes are encoded as
+ * per the RFC.
+ */
+ *ptr++ = (vp->attribute & 0xFF);
+ length_ptr = ptr;
+ *ptr++ = 2;
+ total_length += 2;
+ }
+
+ offset = 0;
+ if (vp->flags.has_tag) {
+ if (TAG_VALID(vp->flags.tag)) {
+ ptr[0] = vp->flags.tag & 0xff;
+ offset = 1;
+
+ } else if (vp->flags.encrypt == FLAG_ENCRYPT_TUNNEL_PASSWORD) {
+ /*
+ * Tunnel passwords REQUIRE a tag, even
+ * if don't have a valid tag.
+ */
+ ptr[0] = 0;
+ offset = 1;
+ } /* else don't write a tag */
+ } /* else the attribute doesn't have a tag */
+
+ /*
+ * Set up the default sources for the data.
+ */
+ data = vp->strvalue;
+ len = vp->length;
+
+ /*
+ * Encrypted passwords can't be very long.
+ * This check also ensures that the hashed version
+ * of the password + attribute header fits into one
+ * attribute.
+ *
+ * FIXME: Print a warning message if it's too long?
+ */
+ if (vp->flags.encrypt && (len > MAX_PASS_LEN)) {
+ len = MAX_PASS_LEN;
+ }
+
+ switch(vp->type) {
+ case PW_TYPE_STRING:
+ case PW_TYPE_OCTETS:
+ case PW_TYPE_IFID:
+ case PW_TYPE_IPV6ADDR:
+ case PW_TYPE_IPV6PREFIX:
+ case PW_TYPE_ABINARY:
+ /* nothing more to do */
+ break;
+
+ case PW_TYPE_INTEGER:
+ len = 4; /* just in case */
+ lvalue = htonl(vp->lvalue);
+ memcpy(array, &lvalue, sizeof(lvalue));
+
+ /*
+ * Perhaps discard the first octet.
+ */
+ data = &array[offset];
+ len -= offset;
+ break;
+
+ case PW_TYPE_IPADDR:
+ data = (const uint8_t *) &vp->lvalue;
+ len = 4; /* just in case */
+ break;
+
+ /*
+ * There are no tagged date attributes.
+ */
+ case PW_TYPE_DATE:
+ lvalue = htonl(vp->lvalue);
+ data = (const uint8_t *) &lvalue;
+ len = 4; /* just in case */
+ break;
+
+ default: /* unknown type: ignore it */
+ librad_log("ERROR: Unknown attribute type %d", vp->type);
+ return -1;
+ }
+
+ /*
+ * Bound the data to 255 bytes.
+ */
+ if (len + offset + total_length > 255) {
+ len = 255 - offset - total_length;
+ }
+
+ /*
+ * Encrypt the various password styles
+ *
+ * Attributes with encrypted values MUST be less than
+ * 128 bytes long.
+ */
+ switch (vp->flags.encrypt) {
+ case FLAG_ENCRYPT_USER_PASSWORD:
+ make_passwd(ptr + offset, &len,
+ data, len,
+ secret, packet->vector);
+ break;
+
+ case FLAG_ENCRYPT_TUNNEL_PASSWORD:
+ if (!original) {
+ librad_log("ERROR: No request packet, cannot encrypt %s attribute in the vp.", vp->name);
+ return -1;
+ }
+
+ make_tunnel_passwd(ptr + offset, &len,
+ data, len,
+ secret, original->vector);
+ break;
+
+ /*
+ * The code above ensures that this attribute
+ * always fits.
+ */
+ case FLAG_ENCRYPT_ASCEND_SECRET:
+ make_secret(ptr + offset, packet->vector,
+ secret, data);
+ len = AUTH_VECTOR_LEN;
+ break;
+
+
+ default:
+ /*
+ * Just copy the data over
+ */
+ memcpy(ptr + offset, data, len);
+ break;
+ } /* switch over encryption flags */
+
+ /*
+ * Account for the tag (if any).
+ */
+ len += offset;
+
+ /*
+ * RFC 2865 section 5 says that zero-length attributes
+ * MUST NOT be sent.
+ */
+ if (len == 0) return 0;
+
+ /*
+ * Update the various lengths.
+ */
+ *length_ptr += len;
+ if (vsa_length_ptr) *vsa_length_ptr += len;
+ ptr += len;
+ total_length += len;
+
+ return total_length; /* of attribute */
+}
+
+
/*
- * Internal prototypes
+ * Encode a packet.
*/
-static void make_secret(unsigned char *digest, uint8_t *vector,
- const char *secret, char *value);
+int rad_encode(RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret)
+{
+ radius_packet_t *hdr;
+ uint8_t *ptr;
+ uint16_t total_length;
+ int len;
+ VALUE_PAIR *reply;
+
+ /*
+ * For simplicity in the following logic, we allow
+ * the attributes to "overflow" the 4k maximum
+ * RADIUS packet size, by one attribute.
+ *
+ * It's uint32_t, for alignment purposes.
+ */
+ uint32_t data[(MAX_PACKET_LEN + 256) / 4];
+
+ /*
+ * Double-check some things based on packet code.
+ */
+ switch (packet->code) {
+ case PW_AUTHENTICATION_ACK:
+ case PW_AUTHENTICATION_REJECT:
+ case PW_ACCESS_CHALLENGE:
+ if (!original) {
+ librad_log("ERROR: Cannot sign response packet without a request packet.");
+ return -1;
+ }
+ break;
+
+ /*
+ * These packet vectors start off as all zero.
+ */
+ case PW_ACCOUNTING_REQUEST:
+ case PW_DISCONNECT_REQUEST:
+ memset(packet->vector, 0, sizeof(packet->vector));
+ break;
+
+ default:
+ break;
+ }
+
+ /*
+ * Use memory on the stack, until we know how
+ * large the packet will be.
+ */
+ hdr = (radius_packet_t *) data;
+
+ /*
+ * Build standard header
+ */
+ hdr->code = packet->code;
+ hdr->id = packet->id;
+
+ memcpy(hdr->vector, packet->vector, sizeof(hdr->vector));
+
+ total_length = AUTH_HDR_LEN;
+ packet->verified = 0;
+
+ /*
+ * Load up the configuration values for the user
+ */
+ ptr = hdr->data;
+
+ /*
+ * FIXME: Loop twice over the reply list. The first time,
+ * calculate the total length of data. The second time,
+ * allocate the memory, and fill in the VP's.
+ *
+ * Hmm... this may be slower than just doing a small
+ * memcpy.
+ */
+
+ /*
+ * Loop over the reply attributes for the packet.
+ */
+ for (reply = packet->vps; reply; reply = reply->next) {
+ /*
+ * Ignore non-wire attributes
+ */
+ if ((VENDOR(reply->attribute) == 0) &&
+ ((reply->attribute & 0xFFFF) > 0xff)) {
+ continue;
+ }
+
+ /*
+ * Check that the packet is no more than 4k in
+ * size, AFTER over-flowing the 4k boundary.
+ * Note that the 'data' buffer, above, is one
+ * attribute longer than necessary, in order to
+ * permit this overflow.
+ */
+ if (total_length > MAX_PACKET_LEN) {
+ librad_log("ERROR: Too many attributes for packet, result is larger than RFC maximum of 4k");
+ return -1;
+ }
+
+ /*
+ * Set the Message-Authenticator to the correct
+ * length and initial value.
+ */
+ if (reply->attribute == PW_MESSAGE_AUTHENTICATOR) {
+ reply->length = AUTH_VECTOR_LEN;
+ memset(reply->strvalue, 0, AUTH_VECTOR_LEN);
+ packet->verified = total_length; /* HACK! */
+ }
+
+ /*
+ * Print out ONLY the attributes which
+ * we're sending over the wire, and print
+ * them out BEFORE they're encrypted.
+ */
+ debug_pair(reply);
+
+ len = rad_vp2attr(packet, original, secret, reply, ptr);
+ if (len < 0) return -1;
+ ptr += len;
+ total_length += len;
+ } /* done looping over all attributes */
+
+ /*
+ * Fill in the rest of the fields, and copy the data over
+ * from the local stack to the newly allocated memory.
+ *
+ * Yes, all this 'memcpy' is slow, but it means
+ * that we only allocate the minimum amount of
+ * memory for a request.
+ */
+ packet->data_len = total_length;
+ packet->data = (uint8_t *) malloc(packet->data_len);
+ if (!packet->data) {
+ librad_log("Out of memory");
+ return -1;
+ }
+
+ memcpy(packet->data, data, packet->data_len);
+ hdr = (radius_packet_t *) packet->data;
+
+ total_length = htons(total_length);
+ memcpy(hdr->length, &total_length, sizeof(total_length));
+
+ return 0;
+}
+
+
+/*
+ * Sign a previously encoded packet.
+ */
+int rad_sign(RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret)
+{
+ radius_packet_t *hdr = (radius_packet_t *)packet->data;
+
+ /*
+ * It wasn't assigned an Id, this is bad!
+ */
+ if (packet->id < 0) {
+ librad_log("ERROR: RADIUS packets must be assigned an Id.");
+ return -1;
+ }
+
+ if (!packet->data || (packet->data_len < AUTH_HDR_LEN) ||
+ (packet->verified < 0)) {
+ librad_log("ERROR: You must call rad_encode() before rad_sign()");
+ return -1;
+ }
+
+ /*
+ * If there's a Message-Authenticator, update it
+ * now, BEFORE updating the authentication vector.
+ *
+ * This is a hack...
+ */
+ if (packet->verified > 0) {
+ uint8_t calc_auth_vector[AUTH_VECTOR_LEN];
+
+ switch (packet->code) {
+ case PW_ACCOUNTING_REQUEST:
+ case PW_ACCOUNTING_RESPONSE:
+ case PW_DISCONNECT_REQUEST:
+ case PW_DISCONNECT_ACK:
+ case PW_DISCONNECT_NAK:
+ case PW_COF_REQUEST:
+ case PW_COF_ACK:
+ case PW_COF_NAK:
+ memset(hdr->vector, 0, AUTH_VECTOR_LEN);
+ break;
+
+ case PW_AUTHENTICATION_ACK:
+ case PW_AUTHENTICATION_REJECT:
+ case PW_ACCESS_CHALLENGE:
+ if (!original) {
+ librad_log("ERROR: Cannot sign response packet without a request packet.");
+ return -1;
+ }
+ memcpy(hdr->vector, original->vector,
+ AUTH_VECTOR_LEN);
+ break;
+
+ default: /* others have vector already set to zero */
+ break;
+
+ }
+
+ /*
+ * Set the authentication vector to zero,
+ * calculate the signature, and put it
+ * into the Message-Authenticator
+ * attribute.
+ */
+ lrad_hmac_md5(packet->data, packet->data_len,
+ secret, strlen(secret),
+ calc_auth_vector);
+ memcpy(packet->data + packet->verified + 2,
+ calc_auth_vector, AUTH_VECTOR_LEN);
+
+ /*
+ * Copy the original request vector back
+ * to the raw packet.
+ */
+ memcpy(hdr->vector, packet->vector, AUTH_VECTOR_LEN);
+ }
+
+ /*
+ * Switch over the packet code, deciding how to
+ * sign the packet.
+ */
+ switch (packet->code) {
+ /*
+ * Request packets are not signed, bur
+ * have a random authentication vector.
+ */
+ case PW_AUTHENTICATION_REQUEST:
+ case PW_STATUS_SERVER:
+ break;
+
+ /*
+ * Reply packets are signed with the
+ * authentication vector of the request.
+ */
+ default:
+ {
+ uint8_t digest[16];
+
+ MD5_CTX context;
+ MD5Init(&context);
+ MD5Update(&context, packet->data, packet->data_len);
+ MD5Update(&context, secret, strlen(secret));
+ MD5Final(digest, &context);
+
+ memcpy(hdr->vector, digest, AUTH_VECTOR_LEN);
+ memcpy(packet->vector, digest, AUTH_VECTOR_LEN);
+ break;
+ }
+ }/* switch over packet codes */
+
+ return 0;
+}
/*
* Reply to the request. Also attach
const char *secret)
{
VALUE_PAIR *reply;
+ const char *what;
+ char ip_buffer[128];
struct sockaddr_in saremote;
struct sockaddr_in *sa;
- const char *what;
- uint8_t ip_buffer[16];
/*
* Maybe it's a fake packet. Don't send it.
* First time through, allocate room for the packet
*/
if (!packet->data) {
- radius_packet_t *hdr;
- uint32_t lvalue;
- uint8_t *ptr, *length_ptr, *vsa_length_ptr;
- uint8_t digest[16];
- int secretlen;
- int vendorcode, vendorpec;
- u_short total_length;
- int len, allowed;
- int msg_auth_offset = 0;
-
- /*
- * For simplicity in the following logic, we allow
- * the attributes to "overflow" the 4k maximum
- * RADIUS packet size, by one attribute.
- */
- uint8_t data[MAX_PACKET_LEN + 256];
-
- /*
- * Use memory on the stack, until we know how
- * large the packet will be.
- */
- hdr = (radius_packet_t *) data;
-
- /*
- * Build standard header
- */
- hdr->code = packet->code;
- hdr->id = packet->id;
-
- /*
- * Double-check some things based on packet code.
- */
- switch (packet->code) {
- case PW_AUTHENTICATION_ACK:
- case PW_AUTHENTICATION_REJECT:
- case PW_ACCESS_CHALLENGE:
- if (!original) {
- librad_log("ERROR: Cannot sign response packet without a request packet.");
- return -1;
- }
- break;
-
- /*
- * These packet vectors start off as all zero.
- */
- case PW_ACCOUNTING_REQUEST:
- case PW_DISCONNECT_REQUEST:
- memset(packet->vector, 0, sizeof(packet->vector));
- break;
-
- default:
- break;
-
- }
- memcpy(hdr->vector, packet->vector, sizeof(hdr->vector));
-
- DEBUG("Sending %s of id %d to %s:%d\n",
- what, packet->id,
- ip_ntoa((char *)ip_buffer, packet->dst_ipaddr),
- packet->dst_port);
-
- total_length = AUTH_HDR_LEN;
-
- /*
- * Load up the configuration values for the user
- */
- ptr = hdr->data;
- vendorcode = 0;
- vendorpec = 0;
- vsa_length_ptr = NULL;
-
- /*
- * Loop over the reply attributes for the packet.
- */
- for (reply = packet->vps; reply; reply = reply->next) {
- /*
- * Ignore non-wire attributes
- */
- if ((VENDOR(reply->attribute) == 0) &&
- ((reply->attribute & 0xFFFF) > 0xff)) {
- continue;
- }
-
- /*
- * Check that the packet is no more than
- * 4k in size, AFTER over-flowing the 4k
- * boundary. Note that the 'data'
- * buffer, above, is one attribute longer
- * than necessary, in order to permit
- * this overflow.
- */
- if (total_length > MAX_PACKET_LEN) {
- librad_log("ERROR: Too many attributes for packet, result is larger than RFC maximum of 4k");
- return -1;
- }
-
- /*
- * Set the Message-Authenticator to the
- * correct length and initial value.
- */
- if (reply->attribute == PW_MESSAGE_AUTHENTICATOR) {
- reply->length = AUTH_VECTOR_LEN;
- memset(reply->strvalue, 0, AUTH_VECTOR_LEN);
- msg_auth_offset = total_length;
- }
-
- /*
- * Print out ONLY the attributes which
- * we're sending over the wire, and print
- * them out BEFORE they're encrypted.
- */
- debug_pair(reply);
-
- /*
- * We have a different vendor. Re-set
- * the vendor codes.
- */
- if (vendorcode != VENDOR(reply->attribute)) {
- vendorcode = 0;
- vendorpec = 0;
- vsa_length_ptr = NULL;
- }
-
- /*
- * If the Vendor-Specific attribute is getting
- * full, then create a new VSA attribute
- *
- * FIXME: Multiple VSA's per Vendor-Specific
- * SHOULD be configurable. When that's done,
- * the (1), below, can be changed to point to
- * a configuration variable which is set TRUE
- * if the NAS cannot understand multiple VSA's
- * per Vendor-Specific
- */
- if ((1) || /* ALWAYS create a new Vendor-Specific */
- (vsa_length_ptr &&
- (reply->length + *vsa_length_ptr) >= MAX_STRING_LEN)) {
- vendorcode = 0;
- vendorpec = 0;
- vsa_length_ptr = NULL;
- }
-
- /*
- * Maybe we have the start of a set of
- * (possibly many) VSA attributes from
- * one vendor. Set a global VSA wrapper
- */
- if ((vendorcode == 0) &&
- ((vendorcode = VENDOR(reply->attribute)) != 0)) {
- vendorpec = dict_vendorpec(vendorcode);
-
- /*
- * This is a potentially bad error...
- * we can't find the vendor ID!
- */
- if (vendorpec == 0) {
- /* FIXME: log an error */
- continue;
- }
-
- /*
- * Build a VSA header.
- */
- *ptr++ = PW_VENDOR_SPECIFIC;
- vsa_length_ptr = ptr;
- *ptr++ = 6;
- lvalue = htonl(vendorpec);
- memcpy(ptr, &lvalue, 4);
- ptr += 4;
- total_length += 6;
- }
-
- if (vendorpec == VENDORPEC_USR) {
- lvalue = htonl(reply->attribute & 0xFFFF);
- memcpy(ptr, &lvalue, 4);
-
- length_ptr = vsa_length_ptr;
-
- total_length += 4;
- *length_ptr += 4;
- ptr += 4;
-
- /*
- * Each USR-style attribute gets
- * it's own VSA wrapper, so we
- * re-set the vendor specific
- * information.
- */
- vendorcode = 0;
- vendorpec = 0;
- vsa_length_ptr = NULL;
-
- } else {
- /*
- * All other attributes are as
- * per the RFC spec.
- */
- *ptr++ = (reply->attribute & 0xFF);
- length_ptr = ptr;
- if (vsa_length_ptr) *vsa_length_ptr += 2;
- *ptr++ = 2;
- total_length += 2;
- }
-
- switch(reply->type) {
-
- /*
- * Ascend binary attributes are
- * stored internally in binary form.
- */
- case PW_TYPE_IFID:
- case PW_TYPE_IPV6ADDR:
- case PW_TYPE_IPV6PREFIX:
- case PW_TYPE_ABINARY:
- case PW_TYPE_STRING:
- case PW_TYPE_OCTETS:
- /*
- * Encrypt the various password styles
- */
- switch (reply->flags.encrypt) {
- default:
- break;
-
- case FLAG_ENCRYPT_USER_PASSWORD:
- rad_pwencode((char *)reply->strvalue,
- &(reply->length),
- (const char *)secret,
- (const char *)packet->vector);
- break;
-
- case FLAG_ENCRYPT_TUNNEL_PASSWORD:
- if (!original) {
- librad_log("ERROR: No request packet, cannot encrypt Tunnel-Password attribute in the reply.");
- return -1;
- }
- rad_tunnel_pwencode(reply->strvalue,
- &(reply->length),
- secret,
- original->vector);
- break;
-
-
- case FLAG_ENCRYPT_ASCEND_SECRET:
- make_secret(digest, packet->vector,
- secret, reply->strvalue);
- memcpy(reply->strvalue, digest, AUTH_VECTOR_LEN );
- reply->length = AUTH_VECTOR_LEN;
- break;
- } /* switch over encryption flags */
-
- len = reply->length;
-
- /*
- * Set the TAG at the beginning
- * of the string if tagged. If
- * tag value is not valid for
- * tagged attribute, make it 0x00
- * per RFC 2868. -cparker
- */
- if (reply->flags.has_tag) {
- if (TAG_VALID(reply->flags.tag)) {
- len++;
- *ptr++ = reply->flags.tag;
-
- } else if (reply->flags.encrypt == FLAG_ENCRYPT_TUNNEL_PASSWORD) {
- /*
- * Tunnel passwords
- * REQUIRE a tag,
- * even if we don't
- * have a valid
- * tag.
- */
- len++;
- *ptr++ = 0x00;
- } /* else don't write a tag */
- } /* else the attribute doesn't have a tag */
-
- /*
- * Ensure we don't go too far.
- * The 'length' of the attribute
- * may be 0..255, minus whatever
- * octets are used in the attribute
- * header.
- */
- allowed = 255;
- if (vsa_length_ptr) {
- allowed -= *vsa_length_ptr;
- } else {
- allowed -= *length_ptr;
- }
-
- if (len > allowed) {
- len = allowed;
- }
-
- *length_ptr += len;
- if (vsa_length_ptr) *vsa_length_ptr += len;
- /*
- * If we have tagged attributes we can't assume that
- * len == reply->length. Use reply->length for copying
- * the string data into the packet. Use len for the
- * true length of the string+tags.
- */
- memcpy(ptr, reply->strvalue, reply->length);
- ptr += reply->length;
- total_length += len;
- break;
-
- case PW_TYPE_INTEGER:
- case PW_TYPE_IPADDR:
- *length_ptr += 4;
- if (vsa_length_ptr) *vsa_length_ptr += 4;
-
- if (reply->type == PW_TYPE_INTEGER ) {
- /* If tagged, the tag becomes the MSB of the value */
- if(reply->flags.has_tag) {
- /* Tag must be ( 0x01 -> 0x1F ) OR 0x00 */
- if(!TAG_VALID(reply->flags.tag)) {
- reply->flags.tag = 0x00;
- }
- lvalue = htonl((reply->lvalue & 0xffffff) |
- ((reply->flags.tag & 0xff) << 24));
- } else {
- lvalue = htonl(reply->lvalue);
- }
- } else {
- /*
- * IP address is already in
- * network byte order.
- */
- lvalue = reply->lvalue;
- }
- memcpy(ptr, &lvalue, 4);
- ptr += 4;
- total_length += 4;
- break;
-
- /*
- * There are no tagged date attributes.
- */
- case PW_TYPE_DATE:
- *length_ptr += 4;
- if (vsa_length_ptr) *vsa_length_ptr += 4;
-
- lvalue = htonl(reply->lvalue);
- memcpy(ptr, &lvalue, 4);
- ptr += 4;
- total_length += 4;
- break;
- default:
- break;
- }
- } /* done looping over all attributes */
-
- /*
- * Fill in the rest of the fields, and copy
- * the data over from the local stack to
- * the newly allocated memory.
- *
- * Yes, all this 'memcpy' is slow, but it means
- * that we only allocate the minimum amount of
- * memory for a request.
- */
- packet->data_len = total_length;
- packet->data = (uint8_t *) malloc(packet->data_len);
- if (!packet->data) {
- librad_log("Out of memory");
- return -1;
- }
- memcpy(packet->data, data, packet->data_len);
- hdr = (radius_packet_t *) packet->data;
-
- total_length = htons(total_length);
- memcpy(hdr->length, &total_length, sizeof(u_short));
-
- /*
- * If this is not an authentication request, we
- * need to calculate the md5 hash over the entire packet
- * and put it in the vector.
- */
- secretlen = strlen(secret);
-
- /*
- * If there's a Message-Authenticator, update it
- * now, BEFORE updating the authentication vector.
- */
- if (msg_auth_offset) {
- uint8_t calc_auth_vector[AUTH_VECTOR_LEN];
-
- switch (packet->code) {
- default:
- break;
-
- case PW_AUTHENTICATION_ACK:
- case PW_AUTHENTICATION_REJECT:
- case PW_ACCESS_CHALLENGE:
- /* this was checked above */
- memcpy(hdr->vector, original->vector,
- AUTH_VECTOR_LEN);
- break;
- }
-
- /*
- * Set the authentication vector to zero,
- * calculate the signature, and put it
- * into the Message-Authenticator
- * attribute.
- */
- memset(packet->data + msg_auth_offset + 2,
- 0, AUTH_VECTOR_LEN);
- lrad_hmac_md5(packet->data, packet->data_len,
- secret, secretlen, calc_auth_vector);
- memcpy(packet->data + msg_auth_offset + 2,
- calc_auth_vector, AUTH_VECTOR_LEN);
-
- /*
- * Copy the original request vector back
- * to the raw packet.
- */
- memcpy(hdr->vector, packet->vector, AUTH_VECTOR_LEN);
- }
-
- /*
- * Switch over the packet code, deciding how to
- * sign the packet.
- */
- switch (packet->code) {
- /*
- * Request packets are not signed, bur
- * have a random authentication vector.
- */
- case PW_AUTHENTICATION_REQUEST:
- case PW_STATUS_SERVER:
- break;
-
- /*
- * Reply packets are signed with the
- * authentication vector of the request.
- */
- default:
- {
- MD5_CTX context;
- MD5Init(&context);
- MD5Update(&context, packet->data, packet->data_len);
- MD5Update(&context, secret, strlen(secret));
- MD5Final(digest, &context);
-
- memcpy(hdr->vector, digest, AUTH_VECTOR_LEN);
- memcpy(packet->vector, digest, AUTH_VECTOR_LEN);
- break;
- }
- } /* switch over packet codes */
-
+ DEBUG("Sending %s of id %d to %s port %d\n",
+ what, packet->id,
+ ip_ntoa(ip_buffer, packet->dst_ipaddr),
+ packet->dst_port);
+
+ /*
+ * Encode the packet.
+ */
+ if (rad_encode(packet, original, secret) < 0) {
+ return -1;
+ }
+
+ /*
+ * Re-sign it, including updating the
+ * Message-Authenticator.
+ */
+ if (rad_sign(packet, original, secret) < 0) {
+ return -1;
+ }
- /*
- * If packet->data points to data, then we print out
- * the VP list again only for debugging.
- */
+ /*
+ * If packet->data points to data, then we print out
+ * the VP list again only for debugging.
+ */
} else if (librad_debug) {
- DEBUG("Re-sending %s of id %d to %s:%d\n", what, packet->id,
- ip_ntoa((char *)ip_buffer, packet->dst_ipaddr),
+ DEBUG("Re-sending %s of id %d to %s port %d\n", what, packet->id,
+ ip_ntoa(ip_buffer, packet->dst_ipaddr),
packet->dst_port);
for (reply = packet->vps; reply; reply = reply->next) {
}
seen_eap |= PW_MESSAGE_AUTHENTICATOR;
break;
-
- case PW_VENDOR_SPECIFIC:
- if (attr[1] <= 6) {
- librad_log("WARNING: Malformed RADIUS packet from host %s: Vendor-Specific has invalid length %d",
- ip_ntoa(host_ipaddr, packet->src_ipaddr),
- attr[1] - 2);
- free(packet);
- return NULL;
- }
-
- /*
- * Don't allow VSA's with vendor zero.
- */
- if ((attr[2] == 0) && (attr[3] == 0) &&
- (attr[4] == 0) && (attr[5] == 0)) {
- librad_log("WARNING: Malformed RADIUS packet from host %s: Vendor-Specific has vendor ID of zero",
- ip_ntoa(host_ipaddr, packet->src_ipaddr));
- free(packet);
- return NULL;
- }
-
- /*
- * Don't look at the contents of VSA's,
- * too many vendors have non-standard
- * formats.
- */
- break;
}
/*
return packet;
}
+
/*
- * Calculate/check digest, and decode radius attributes.
+ * Verify the signature of a packet.
*/
-int rad_decode(RADIUS_PACKET *packet, RADIUS_PACKET *original,
+static int rad_verify(RADIUS_PACKET *packet, RADIUS_PACKET *original,
const char *secret)
{
- uint32_t lvalue;
- uint32_t vendorcode;
- VALUE_PAIR **tail;
- VALUE_PAIR *pair;
uint8_t *ptr;
int length;
- int attribute;
int attrlen;
- int vendorlen;
- radius_packet_t *hdr;
- hdr = (radius_packet_t *)packet->data;
+ if (!packet || !packet->data) return -1;
/*
* Before we allocate memory for the attributes, do more
* sanity checking.
*/
- ptr = hdr->data;
+ ptr = packet->data + AUTH_HDR_LEN;
length = packet->data_len - AUTH_HDR_LEN;
while (length > 0) {
uint8_t msg_auth_vector[AUTH_VECTOR_LEN];
switch (packet->code) {
default:
- break;
+ break;
+
+ case PW_ACCOUNTING_REQUEST:
+ case PW_ACCOUNTING_RESPONSE:
+ case PW_DISCONNECT_REQUEST:
+ case PW_DISCONNECT_ACK:
+ case PW_DISCONNECT_NAK:
+ case PW_COF_REQUEST:
+ case PW_COF_ACK:
+ case PW_COF_NAK:
+ memset(packet->data + 4, 0, AUTH_VECTOR_LEN);
+ break;
case PW_AUTHENTICATION_ACK:
case PW_AUTHENTICATION_REJECT:
case PW_ACCESS_CHALLENGE:
- if (!original) {
- librad_log("ERROR: Cannot validate Message-Authenticator in response packet without a request packet.");
- return -1;
- }
- memcpy(packet->data + 4, original->vector, AUTH_VECTOR_LEN);
- break;
+ if (!original) {
+ librad_log("ERROR: Cannot validate Message-Authenticator in response packet without a request packet.");
+ return -1;
+ }
+ memcpy(packet->data + 4, original->vector, AUTH_VECTOR_LEN);
+ break;
}
lrad_hmac_md5(packet->data, packet->data_len,
secret, strlen(secret), calc_auth_vector);
if (memcmp(calc_auth_vector, msg_auth_vector,
- sizeof(calc_auth_vector)) != 0) {
+ sizeof(calc_auth_vector)) != 0) {
char buffer[32];
librad_log("Received packet from %s with invalid Message-Authenticator! (Shared secret is incorrect.)",
ip_ntoa(buffer, packet->src_ipaddr));
- return -1;
+ /* Silently drop packet, according to RFC 3579 */
+ return -2;
} /* else the message authenticator was good */
/*
break;
} /* switch over the attributes */
- ptr += attrlen;
- length -= attrlen;
- } /* loop over the packet, sanity checking the attributes */
+ ptr += attrlen;
+ length -= attrlen;
+ } /* loop over the packet, sanity checking the attributes */
+
+ /*
+ * Calculate and/or verify digest.
+ */
+ switch(packet->code) {
+ int rcode;
+
+ case PW_AUTHENTICATION_REQUEST:
+ case PW_STATUS_SERVER:
+ case PW_DISCONNECT_REQUEST:
+ /*
+ * The authentication vector is random
+ * nonsense, invented by the client.
+ */
+ break;
+
+ case PW_ACCOUNTING_REQUEST:
+ if (calc_acctdigest(packet, secret) > 1) {
+ char buffer[32];
+ librad_log("Received Accounting-Request packet "
+ "from %s with invalid signature! (Shared secret is incorrect.)",
+ ip_ntoa(buffer, packet->src_ipaddr));
+ return -1;
+ }
+ break;
+
+ /* Verify the reply digest */
+ case PW_AUTHENTICATION_ACK:
+ case PW_AUTHENTICATION_REJECT:
+ case PW_ACCOUNTING_RESPONSE:
+ rcode = calc_replydigest(packet, original, secret);
+ if (rcode > 1) {
+ char buffer[32];
+ librad_log("Received %s packet "
+ "from client %s port %d with invalid signature (err=%d)! (Shared secret is incorrect.)",
+ packet_codes[packet->code],
+ ip_ntoa(buffer, packet->src_ipaddr),
+ packet->src_port,
+ rcode);
+ return -1;
+ }
+ break;
+ }
+
+ return 0;
+}
+
+
+/*
+ * Parse a RADIUS attribute into a data structure.
+ */
+static VALUE_PAIR *rad_attr2vp(const RADIUS_PACKET *packet, const RADIUS_PACKET *original,
+ const char *secret, int attribute, int length,
+ const uint8_t *data)
+{
+ int offset = 0;
+ VALUE_PAIR *vp;
+
+ if ((vp = paircreate(attribute, PW_TYPE_OCTETS)) == NULL) {
+ return NULL;
+ }
+
+ /*
+ * If length is greater than 253, something is SERIOUSLY
+ * wrong.
+ */
+ if (length > 253) length = 253; /* paranoia (pair-anoia?) */
+
+ vp->length = length;
+ vp->operator = T_OP_EQ;
+ vp->next = NULL;
+
+ /*
+ * Handle tags.
+ */
+ if (vp->flags.has_tag) {
+ if (TAG_VALID(data[0]) ||
+ (vp->flags.encrypt == FLAG_ENCRYPT_TUNNEL_PASSWORD)) {
+ /*
+ * Tunnel passwords REQUIRE a tag, even
+ * if don't have a valid tag.
+ */
+ vp->flags.tag = data[0];
+
+ if ((vp->type == PW_TYPE_STRING) ||
+ (vp->type == PW_TYPE_OCTETS)) offset = 1;
+ }
+ }
+
+ /*
+ * Copy the data to be decrypted
+ */
+ memcpy(&vp->strvalue[0], data + offset, length - offset);
+ vp->length -= offset;
+
+ /*
+ * Decrypt the attribute.
+ */
+ switch (vp->flags.encrypt) {
+ /*
+ * User-Password
+ */
+ case FLAG_ENCRYPT_USER_PASSWORD:
+ if (original) {
+ rad_pwdecode((char *)vp->strvalue,
+ vp->length, secret,
+ original->vector);
+ } else {
+ rad_pwdecode((char *)vp->strvalue,
+ vp->length, secret,
+ packet->vector);
+ }
+ if (vp->attribute == PW_USER_PASSWORD) {
+ vp->length = strlen(vp->strvalue);
+ }
+ break;
+
+ /*
+ * Tunnel-Password's may go ONLY
+ * in response packets.
+ */
+ case FLAG_ENCRYPT_TUNNEL_PASSWORD:
+ if (!original) goto raw;
+
+ if (rad_tunnel_pwdecode(vp->strvalue, &vp->length,
+ secret, original->vector) < 0) {
+ goto raw;
+ }
+ break;
+
+ /*
+ * Ascend-Send-Secret
+ * Ascend-Receive-Secret
+ */
+ case FLAG_ENCRYPT_ASCEND_SECRET:
+ if (!original) {
+ goto raw;
+ } else {
+ uint8_t my_digest[AUTH_VECTOR_LEN];
+ make_secret(my_digest,
+ original->vector,
+ secret, data);
+ memcpy(vp->strvalue, my_digest,
+ AUTH_VECTOR_LEN );
+ vp->strvalue[AUTH_VECTOR_LEN] = '\0';
+ vp->length = strlen(vp->strvalue);
+ }
+ break;
+
+ default:
+ break;
+ } /* switch over encryption flags */
+
+
+ switch (vp->type) {
+ case PW_TYPE_STRING:
+ case PW_TYPE_OCTETS:
+ /* nothing more to do */
+ break;
+
+ case PW_TYPE_INTEGER:
+ if (vp->length != 4) goto raw;
+
+ memcpy(&vp->lvalue, vp->strvalue, 4);
+ vp->lvalue = ntohl(vp->lvalue);
+
+ if (vp->flags.has_tag) vp->lvalue &= 0x00ffffff;
+
+ /*
+ * Try to get named VALUEs
+ */
+ {
+ DICT_VALUE *dval;
+ dval = dict_valbyattr(vp->attribute,
+ vp->lvalue);
+ if (dval) {
+ strNcpy(vp->strvalue,
+ dval->name,
+ sizeof(vp->strvalue));
+ }
+ }
+ break;
+
+ case PW_TYPE_DATE:
+ if (vp->length != 4) goto raw;
+
+ memcpy(&vp->lvalue, vp->strvalue, 4);
+ vp->lvalue = ntohl(vp->lvalue);
+ break;
+
+
+ case PW_TYPE_IPADDR:
+ if (vp->length != 4) goto raw;
+
+ memcpy(&vp->lvalue, vp->strvalue, 4);
+ break;
+
+ /*
+ * IPv6 interface ID is 8 octets long.
+ */
+ case PW_TYPE_IFID:
+ if (vp->length != 8) goto raw;
+ /* vp->vp_ifid == vp->strvalue */
+ break;
+
+ /*
+ * IPv6 addresses are 16 octets long
+ */
+ case PW_TYPE_IPV6ADDR:
+ if (vp->length != 16) goto raw;
+ /* vp->vp_ipv6addr == vp->strvalue */
+ break;
+
+ /*
+ * IPv6 prefixes are 2 to 18 octets long.
+ *
+ * RFC 3162: The first octet is unused.
+ * The second is the length of the prefix
+ * the rest are the prefix data.
+ *
+ * The prefix length can have value 0 to 128.
+ */
+ case PW_TYPE_IPV6PREFIX:
+ if (vp->length < 2 || vp->length > 18) goto raw;
+ if (vp->strvalue[1] > 128) goto raw;
+
+ /*
+ * FIXME: double-check that
+ * (vp->strvalue[1] >> 3) matches vp->length + 2
+ */
+ if (vp->length < 18) {
+ memset(vp->strvalue + vp->length, 0,
+ 18 - vp->length);
+ }
+ break;
- /*
- * Calculate and/or verify digest.
- */
- switch(packet->code) {
- int rcode;
+ default:
+ raw:
+ vp->type = PW_TYPE_OCTETS;
+ vp->length = length;
+ memcpy(vp->strvalue, data, length);
+
- case PW_AUTHENTICATION_REQUEST:
- case PW_STATUS_SERVER:
- case PW_DISCONNECT_REQUEST:
- /*
- * The authentication vector is random
- * nonsense, invented by the client.
- */
- break;
+ /*
+ * Ensure there's no encryption or tag stuff,
+ * we just pass the attribute as-is.
+ */
+ memset(&vp->flags, 0, sizeof(vp->flags));
+ }
- case PW_ACCOUNTING_REQUEST:
- if (calc_acctdigest(packet, secret) > 1) {
- char buffer[32];
- librad_log("Received Accounting-Request packet "
- "from %s with invalid signature! (Shared secret is incorrect.)",
- ip_ntoa(buffer, packet->src_ipaddr));
- return -1;
- }
- break;
+ return vp;
+}
- /* Verify the reply digest */
- case PW_AUTHENTICATION_ACK:
- case PW_AUTHENTICATION_REJECT:
- case PW_ACCOUNTING_RESPONSE:
- rcode = calc_replydigest(packet, original, secret);
- if (rcode > 1) {
- char buffer[32];
- librad_log("Received %s packet "
- "from %s:%d with invalid signature (err=%d)! (Shared secret is incorrect.)",
- packet_codes[packet->code],
- ip_ntoa(buffer, packet->src_ipaddr),
- packet->src_port,
- rcode);
- return -1;
- }
- break;
- }
+
+/*
+ * Calculate/check digest, and decode radius attributes.
+ */
+int rad_decode(RADIUS_PACKET *packet, RADIUS_PACKET *original,
+ const char *secret)
+{
+ uint32_t lvalue;
+ uint32_t vendorcode;
+ VALUE_PAIR **tail;
+ VALUE_PAIR *pair;
+ uint8_t *ptr;
+ int packet_length;
+ int attribute;
+ int attrlen;
+ int vendorlen;
+ radius_packet_t *hdr;
+ int vsa_tlen, vsa_llen;
+ DICT_VENDOR *dv = NULL;
+
+ if (rad_verify(packet, original, secret) < 0) return -1;
/*
* Extract attribute-value pairs
*/
+ hdr = (radius_packet_t *)packet->data;
ptr = hdr->data;
- length = packet->data_len - AUTH_HDR_LEN;
+ packet_length = packet->data_len - AUTH_HDR_LEN;
/*
* There may be VP's already in the packet. Don't
vendorcode = 0;
vendorlen = 0;
+ vsa_tlen = vsa_llen = 1;
+
+ /*
+ * We have to read at least two bytes.
+ *
+ * rad_recv() above ensures that this is OK.
+ */
+ while (packet_length > 0) {
+ attribute = -1;
+ attrlen = -1;
+
+ /*
+ * Normal attribute, handle it like normal.
+ */
+ if (vendorcode == 0) {
+ /*
+ * No room to read attr/length,
+ * or bad attribute, or attribute is
+ * too short, or attribute is too long,
+ * stop processing the packet.
+ */
+ if ((packet_length < 2) ||
+ (ptr[0] == 0) || (ptr[1] < 2) ||
+ (ptr[1] > packet_length)) break;
- while (length > 0) {
- if (vendorlen > 0) {
- attribute = *ptr++ | (vendorcode << 16);
- attrlen = *ptr++;
- } else {
attribute = *ptr++;
attrlen = *ptr++;
- }
- attrlen -= 2;
- length -= 2;
+ attrlen -= 2;
+ packet_length -= 2;
+ if (attribute != PW_VENDOR_SPECIFIC) goto create_pair;
+
+ /*
+ * No vendor code, or ONLY vendor code.
+ */
+ if (attrlen <= 4) goto create_pair;
+
+ vendorlen = 0;
+ }
+
/*
- * This could be a Vendor-Specific attribute.
+ * Handle Vendor-Specific
*/
- if ((vendorlen <= 0) &&
- (attribute == PW_VENDOR_SPECIFIC)) {
- int sublen;
- uint8_t *subptr;
-
+ if (vendorlen == 0) {
+ uint8_t *subptr;
+ int sublen;
+ int myvendor;
+
/*
- * attrlen was checked to be >= 6, in rad_recv
+ * attrlen was checked above.
*/
memcpy(&lvalue, ptr, 4);
- vendorcode = ntohl(lvalue);
+ myvendor = ntohl(lvalue);
/*
+ * Zero isn't allowed.
+ */
+ if (myvendor == 0) goto create_pair;
+
+ /*
* This is an implementation issue.
* We currently pack vendor into the upper
* 16 bits of a 32-bit attribute number,
* so we can't handle vendor numbers larger
* than 16 bits.
*/
- if (vendorcode > 65535) goto create_pair;
-
- /*
- * vendorcode was checked to be non-zero
- * above, in rad_recv.
- */
-
+ if (myvendor > 65535) goto create_pair;
+
+ vsa_tlen = vsa_llen = 1;
+ dv = dict_vendorbyvalue(myvendor);
+ if (dv) {
+ vsa_tlen = dv->type;
+ vsa_llen = dv->length;
+ }
+
/*
- * First, check to see if the
- * sub-attributes fill the VSA, as
- * defined by the RFC. If not, then it
- * may be a USR-style VSA, or it may be a
- * vendor who packs all of the
- * information into one nonsense
- * attribute
+ * Sweep through the list of VSA's,
+ * seeing if they exactly fill the
+ * outer Vendor-Specific attribute.
+ *
+ * If not, create a raw Vendor-Specific.
*/
subptr = ptr + 4;
sublen = attrlen - 4;
- while (sublen > 0) {
- if (subptr[1] < 2) { /* too short */
- break;
- }
-
- if (subptr[1] > sublen) { /* too long */
- break;
- }
-
- sublen -= subptr[1]; /* just right */
- subptr += subptr[1];
- }
-
/*
- * If the attribute is RFC compatible,
- * then allow it as an RFC style VSA.
+ * See if we can parse it.
*/
- if (sublen == 0) {
- ptr += 4;
- vendorlen = attrlen - 4;
- attribute = *ptr++ | (vendorcode << 16);
- attrlen = *ptr++;
- attrlen -= 2;
- length -= 6;
-
- /*
- * USR-style attributes are 4 octets,
- * with the upper 2 octets being zero.
- *
- * The upper octets may not be zero,
- * but that then means we won't be
- * able to pack the vendor & attribute
- * into a 32-bit number, so we can't
- * handle it.
- *
- *
- * FIXME: Update the dictionaries so
- * that we key off of per-attribute
- * flags "4-octet", instead of hard
- * coding USR here. This will also
- * let us send packets with other
- * vendors having 4-octet attributes.
- */
- } else if ((vendorcode == VENDORPEC_USR) &&
- ((ptr[4] == 0) && (ptr[5] == 0)) &&
- (attrlen >= 8)) {
- DICT_ATTR *da;
-
- da = dict_attrbyvalue((vendorcode << 16) |
- (ptr[6] << 8) |
- ptr[7]);
+ do {
+ int myattr = 0;
/*
- * See if it's in the dictionary.
- * If so, it's a valid USR style
- * attribute. If not, it's not...
- *
- * Don't touch 'attribute' until
- * we know what to do!
+ * Don't have a type, it's bad.
*/
- if (da != NULL) {
- attribute = ((vendorcode << 16) |
- (ptr[6] << 8) |
- ptr[7]);
- ptr += 8;
- attrlen -= 8;
- length -= 8;
- } /* else it's not in the dictionary */
- } /* else it was a stupid vendor format */
- } /* else it wasn't a VSA */
-
- /*
- * Create the attribute, setting the default type
- * to 'octects'. If the type in the dictionary
- * is different, then the dictionary type will
- * over-ride this one.
- */
- create_pair:
- if ((pair = paircreate(attribute, PW_TYPE_OCTETS)) == NULL) {
- pairfree(&packet->vps);
- librad_log("out of memory");
- return -1;
- }
-
- pair->length = attrlen;
- pair->operator = T_OP_EQ;
- pair->next = NULL;
-
- switch (pair->type) {
-
- /*
- * The attribute may be zero length,
- * or it may have a tag, and then no data...
- */
- case PW_TYPE_STRING:
- if (pair->flags.has_tag) {
- int offset = 0;
-
+ if (sublen < vsa_tlen) goto create_pair;
+
/*
- * If there's sufficient room for
- * a tag, and the tag looks valid,
- * then use it.
+ * Ensure that the attribute number
+ * is OK.
*/
- if ((pair->length > 0) &&
- TAG_VALID_ZERO(*ptr)) {
- pair->flags.tag = *ptr;
- pair->length--;
- offset = 1;
-
- /*
- * If the leading tag
- * isn't valid, then it's
- * ignored for the tunnel
- * password attribute.
- */
- } else if (pair->flags.encrypt == FLAG_ENCRYPT_TUNNEL_PASSWORD) {
+ switch (vsa_tlen) {
+ case 1:
+ myattr = subptr[0];
+ break;
+
+ case 2:
+ myattr = (subptr[0] << 8) | subptr[1];
+ break;
+
+ case 4:
+ if ((subptr[0] != 0) ||
+ (subptr[1] != 0)) goto create_pair;
+
+ myattr = (subptr[2] << 8) | subptr[3];
+ break;
+
/*
- * from RFC2868 - 3.5. Tunnel-Password
- * If the value of the Tag field is greater than
- * 0x00 and less than or equal to 0x1F, it SHOULD
- * be interpreted as indicating which tunnel
- * (of several alternatives) this attribute pertains;
- * otherwise, the Tag field SHOULD be ignored.
+ * Our dictionary is broken.
*/
- pair->flags.tag = 0x00;
- if (pair->length > 0) pair->length--;
- offset = 1;
- } else {
- pair->flags.tag = 0x00;
+ default:
+ goto create_pair;
}
-
- /*
- * pair->length MAY be zero here.
- */
- memcpy(pair->strvalue, ptr + offset,
- pair->length);
- } else {
- /*
- * Ascend binary attributes never have a
- * tag, and neither do the 'octets' type.
- */
- case PW_TYPE_ABINARY:
- case PW_TYPE_OCTETS:
- /* attrlen always < MAX_STRING_LEN */
- memcpy(pair->strvalue, ptr, attrlen);
- pair->flags.tag = 0;
- }
-
- /*
- * Decrypt passwords here.
- */
- switch (pair->flags.encrypt) {
- default:
- break;
-
+
/*
- * User-Password
+ * Not enough room for one more
+ * attribute. Die!
*/
- case FLAG_ENCRYPT_USER_PASSWORD:
- if (original) {
- rad_pwdecode((char *)pair->strvalue,
- pair->length, secret,
- (char *)original->vector);
- } else {
- rad_pwdecode((char *)pair->strvalue,
- pair->length, secret,
- (char *)packet->vector);
- }
- if (pair->attribute == PW_USER_PASSWORD) {
- pair->length = strlen(pair->strvalue);
- }
- break;
+ if (sublen < vsa_tlen + vsa_llen) goto create_pair;
+ switch (vsa_llen) {
+ case 0:
+ attribute = (myvendor << 16) | myattr;
+ ptr += 4 + vsa_tlen;
+ attrlen -= (4 + vsa_tlen);
+ packet_length -= 4 + vsa_tlen;
+ goto create_pair;
+
+ case 1:
+ if (subptr[vsa_tlen] < (vsa_tlen + vsa_llen))
+ goto create_pair;
+
+ if (subptr[vsa_tlen] > sublen)
+ goto create_pair;
+ sublen -= subptr[vsa_tlen];
+ subptr += subptr[vsa_tlen];
+ break;
- /*
- * Tunnel-Password's may go ONLY
- * in response packets.
- */
- case FLAG_ENCRYPT_TUNNEL_PASSWORD:
- if (!original) {
- librad_log("ERROR: Tunnel-Password attribute in request: Cannot decrypt it.");
- free(pair);
- return -1;
- }
- if (rad_tunnel_pwdecode(pair->strvalue,
- &pair->length,
- secret,
- (char *)original->vector) < 0) {
- free(pair);
- return -1;
- }
- break;
+ case 2:
+ if (subptr[vsa_tlen] != 0) goto create_pair;
+ if (subptr[vsa_tlen + 1] < (vsa_tlen + vsa_llen))
+ goto create_pair;
+ if (subptr[vsa_tlen + 1] > sublen)
+ goto create_pair;
+ sublen -= subptr[vsa_tlen + 1];
+ subptr += subptr[vsa_tlen + 1];
+ break;
- /*
- * Ascend-Send-Secret
- * Ascend-Receive-Secret
- */
- case FLAG_ENCRYPT_ASCEND_SECRET:
- if (!original) {
- librad_log("ERROR: Ascend-Send-Secret attribute in request: Cannot decrypt it.");
- free(pair);
- return -1;
- } else {
- uint8_t my_digest[AUTH_VECTOR_LEN];
- make_secret(my_digest,
- original->vector,
- secret, ptr);
- memcpy(pair->strvalue, my_digest,
- AUTH_VECTOR_LEN );
- pair->strvalue[AUTH_VECTOR_LEN] = '\0';
- pair->length = strlen(pair->strvalue);
+ /*
+ * Our dictionaries are
+ * broken.
+ */
+ default:
+ goto create_pair;
}
- break;
- } /* switch over encryption flags */
- break; /* from octets/string/abinary */
+ } while (sublen > 0);
- case PW_TYPE_INTEGER:
- case PW_TYPE_DATE:
- case PW_TYPE_IPADDR:
- /*
- * Check for RFC compliance. If the
- * attribute isn't compliant, turn it
- * into a string of raw octets.
- *
- * Also set the lvalue to something
- * which should never match anything.
- */
- if (attrlen != 4) {
- pair->type = PW_TYPE_OCTETS;
- memcpy(pair->strvalue, ptr, attrlen);
- pair->lvalue = 0xbad1bad1;
- break;
- }
-
- memcpy(&lvalue, ptr, 4);
-
- if (pair->type != PW_TYPE_IPADDR) {
- pair->lvalue = ntohl(lvalue);
- } else {
- /*
- * It's an IP address, keep it in network
- * byte order, and put the ASCII IP
- * address or host name into the string
- * value.
- */
- pair->lvalue = lvalue;
- ip_ntoa(pair->strvalue, pair->lvalue);
- }
+ vendorcode = myvendor;
+ vendorlen = attrlen - 4;
+ packet_length -= 4;
- /*
- * Tagged attributes of type integer have
- * special treatment.
- */
- if (pair->flags.has_tag &&
- pair->type == PW_TYPE_INTEGER) {
- pair->flags.tag = (pair->lvalue >> 24) & 0xff;
- pair->lvalue &= 0x00ffffff;
- }
+ ptr += 4;
+ }
- /*
- * Try to get the name for integer
- * attributes.
- */
- if (pair->type == PW_TYPE_INTEGER) {
- DICT_VALUE *dval;
- dval = dict_valbyattr(pair->attribute,
- pair->lvalue);
- if (dval) {
- strNcpy(pair->strvalue,
- dval->name,
- sizeof(pair->strvalue));
- }
- }
+ /*
+ * attrlen is the length of this attribute.
+ * total_len is the length of the encompassing
+ * attribute.
+ */
+ switch (vsa_tlen) {
+ case 1:
+ attribute = ptr[0];
break;
-
- /*
- * IPv6 interface ID is 8 octets long.
- */
- case PW_TYPE_IFID:
- if (attrlen != 8)
- pair->type = PW_TYPE_OCTETS;
- memcpy(pair->strvalue, ptr, attrlen);
+
+ case 2:
+ attribute = (ptr[0] << 8) | ptr[1];
break;
- /*
- * IPv6 addresses are 16 octets long
- */
- case PW_TYPE_IPV6ADDR:
- if (attrlen != 16)
- pair->type = PW_TYPE_OCTETS;
- memcpy(pair->strvalue, ptr, attrlen);
- break;
+ default: /* can't hit this. */
+ return -1;
+ }
+ attribute |= (vendorcode << 16);
+ ptr += vsa_tlen;
- /*
- * IPv6 prefixes are 2 to 18 octets long.
- *
- * RFC 3162: The first octet is unused.
- * The second is the length of the prefix
- * the rest are the prefix data.
- *
- * The prefix length can have value 0 to 128.
- */
- case PW_TYPE_IPV6PREFIX:
- if (attrlen < 2 || attrlen > 18)
- pair->type = PW_TYPE_OCTETS;
- if (attrlen >= 2) {
- if (ptr[1] > 128) {
- pair->type = PW_TYPE_OCTETS;
- }
- /*
- * FIXME: double-check that
- * (ptr[1] >> 3) matches attrlen + 2
- */
- }
- memcpy(pair->strvalue, ptr, attrlen);
+ switch (vsa_llen) {
+ case 1:
+ attrlen = ptr[0] - (vsa_tlen + vsa_llen);
break;
-
- default:
- DEBUG(" %s (Unknown Type %d)\n",
- pair->name, pair->type);
- free(pair);
- pair = NULL;
+
+ case 2:
+ attrlen = ptr[1] - (vsa_tlen + vsa_llen);
break;
+
+ default: /* can't hit this. */
+ return -1;
}
+ ptr += vsa_llen;
+ vendorlen -= vsa_tlen + vsa_llen + attrlen;
+ if (vendorlen == 0) vendorcode = 0;
+ packet_length -= (vsa_tlen + vsa_llen);
- if (pair) {
- debug_pair(pair);
- *tail = pair;
- tail = &pair->next;
+ /*
+ * Create the attribute, setting the default type
+ * to 'octects'. If the type in the dictionary
+ * is different, then the dictionary type will
+ * over-ride this one.
+ */
+ create_pair:
+ pair = rad_attr2vp(packet, original, secret,
+ attribute, attrlen, ptr);
+ if (!pair) {
+ pairfree(&packet->vps);
+ librad_log("out of memory");
+ return -1;
}
+ debug_pair(pair);
+ *tail = pair;
+ tail = &pair->next;
+
ptr += attrlen;
- length -= attrlen;
- if (vendorlen > 0) vendorlen -= (attrlen + 2);
+ packet_length -= attrlen;
}
/*
* Merge information from the outside world into our
- * random pool
+ * random pool.
*/
- for (length = 0; length < AUTH_VECTOR_LEN; length++) {
- lrad_rand_pool.randmem[length] += packet->vector[length];
- }
- lrad_rand_pool.randmem[lrad_rand_pool.randmem[0] & 0xff] += packet->id;
- lrad_rand_pool.randmem[lrad_rand_pool.randmem[1] & 0xff] += packet->data_len;
-
+ lrad_rand_seed(packet->data, AUTH_HDR_LEN);
+
return 0;
}
* int *pwlen is updated to the new length of the encrypted
* password - a multiple of 16 bytes.
*/
-#define AUTH_PASS_LEN (16)
int rad_pwencode(char *passwd, int *pwlen, const char *secret,
const char *vector)
{
return pwlen;
}
-static unsigned int salt_offset = 0;
/*
* Encode Tunnel-Password attributes when sending them out on the wire.
return 0;
}
+
/*
- * Create a random vector of AUTH_VECTOR_LEN bytes.
+ * Seed the random number generator.
+ *
+ * May be called any number of times.
*/
-static void random_vector(uint8_t *vector)
+void lrad_rand_seed(const void *data, size_t size)
{
- int i;
+ uint32_t hash;
- if (!lrad_pool_initialized) {
+ /*
+ * Ensure that the pool is initialized.
+ */
+ if (lrad_rand_index < 0) {
+ int fd;
+
memset(&lrad_rand_pool, 0, sizeof(lrad_rand_pool));
- /*
- * Initialize the state to something, using
- * numbers which aren't random, but which also
- * aren't static.
- */
- lrad_rand_pool.randrsl[0] = (uint32_t) &lrad_pool_initialized;
- lrad_rand_pool.randrsl[1] = (uint32_t) &i;
- lrad_rand_pool.randrsl[2] = (uint32_t) vector;
+ fd = open("/dev/urandom", O_RDONLY);
+ if (fd >= 0) {
+ size_t total;
+ ssize_t this;
+
+ total = this = 0;
+ while (total < sizeof(lrad_rand_pool.randrsl)) {
+ this = read(fd, lrad_rand_pool.randrsl,
+ sizeof(lrad_rand_pool.randrsl) - total);
+ if ((this < 0) && (errno != EINTR)) break;
+ if (this > 0) total += this;
+ }
+ close(fd);
+ } else {
+ lrad_rand_pool.randrsl[0] = fd;
+ lrad_rand_pool.randrsl[1] = time(NULL);
+ lrad_rand_pool.randrsl[2] = errno;
+ }
lrad_randinit(&lrad_rand_pool, 1);
- lrad_pool_initialized = 1;
+ lrad_rand_index = 0;
}
- lrad_isaac(&lrad_rand_pool);
+ if (!data) return;
+
+ /*
+ * Hash the user data
+ */
+ hash = lrad_hash(data, size);
+
+ lrad_rand_pool.randrsl[lrad_rand_index & 0xff] ^= hash;
+ lrad_rand_index++;
+ lrad_rand_index &= 0xff;
/*
- * Copy the random data over.
+ * Churn the pool every so often after seeding it.
*/
- for (i = 0; i < AUTH_VECTOR_LEN; i++) {
- *(vector++) = lrad_rand_pool.randrsl[i] & 0xff;
+ if (((int) (hash & 0xff)) == lrad_rand_index) {
+ lrad_isaac(&lrad_rand_pool);
}
}
+
/*
* Return a 32-bit random number.
*/
uint32_t lrad_rand(void)
{
- uint32_t answer;
- static int rand_index = 0;
+ uint32_t num;
/*
* Ensure that the pool is initialized.
*/
- if (!lrad_pool_initialized) {
- uint8_t vector[AUTH_VECTOR_LEN];
-
- random_vector(vector);
+ if (lrad_rand_index < 0) {
+ lrad_rand_seed(NULL, 0);
}
/*
- * Grab an entry from the pool.
- */
- answer = lrad_rand_pool.randrsl[rand_index];
-
- /*
- * Go to the next entry (wrapping around to zero).
+ * We don't return data directly from the pool.
+ * Rather, we return a summary of the data.
*/
- rand_index++;
- rand_index &= 0xff;
+ num = lrad_rand_pool.randrsl[lrad_rand_index & 0xff];
+ lrad_rand_index++;
+ lrad_rand_index &= 0xff;
/*
- * Every 256 numbers, churn the pool again.
+ * Every so often, churn the pool.
*/
- if (rand_index == 0) {
+ if (((int) (num & 0xff)) == lrad_rand_index) {
lrad_isaac(&lrad_rand_pool);
}
- return answer;
+ return num;
}
/*
return NULL;
}
memset(rp, 0, sizeof(RADIUS_PACKET));
- if (newvector)
- random_vector(rp->vector);
+ if (newvector) {
+ int i;
+ uint32_t hash, base;
+
+ /*
+ * Don't expose the actual contents of the random
+ * pool.
+ */
+ base = lrad_rand();
+ for (i = 0; i < AUTH_VECTOR_LEN; i += sizeof(uint32_t)) {
+ hash = lrad_rand() ^ base;
+ memcpy(rp->vector + i, &hash, sizeof(hash));
+ }
+ }
lrad_rand();
return rp;
*radius_packet_ptr = NULL;
}
-
-/*************************************************************************
- *
- * Function: make_secret
- *
- * Purpose: Build an encrypted secret value to return in a reply
- * packet. The secret is hidden by xoring with a MD5 digest
- * created from the shared secret and the authentication
- * vector. We put them into MD5 in the reverse order from
- * that used when encrypting passwords to RADIUS.
- *
- *************************************************************************/
-static void make_secret(unsigned char *digest, uint8_t *vector,
- const char *secret, char *value)
-{
- u_char buffer[256 + AUTH_VECTOR_LEN];
- int secretLen = strlen(secret);
- int i;
-
- memcpy(buffer, vector, AUTH_VECTOR_LEN );
- memcpy(buffer + AUTH_VECTOR_LEN, secret, secretLen );
-
- librad_md5_calc(digest, buffer, AUTH_VECTOR_LEN + secretLen );
- memset(buffer, 0, sizeof(buffer));
-
- for ( i = 0; i < AUTH_VECTOR_LEN; i++ ) {
- digest[i] ^= value[i];
- }
-}